Keating Of Chicago Fryer 037981 User Manual

S E R V I C E I N S T R U C T I O N S  
Part # 037983  
1-800-KEATING  
INSTALLATION INSTRUCTIONS FOR SPARK  
IGNITION MODULE #037981  
For IFMs With Spark Iginition Module Mounted in the Blower Box  
1. Remove blower box front cover from the cabinet. Remove blower box cover from the base plate exposing the obso-  
lete dual electrode spark iginition module (Part # 019724) and the relight circuit box.  
FIG 1. WIRING DIAGRAM FOR IFMs WITH DUAL−ELECTRODE SPARK IGNITION  
MODULE (PART # 019724) AND RELIGHT CIRCUIT  
2. Locate wire # 16, 20, 18 and 69 between the old spark module and relight circuit. Disconnect and discard the wires.  
Discard the wire # 15 and 17 connected between the terminal board and relight circuit.  
3. Disconnect wire # 16, 20, 23, 31, and 69 from the old spark module.  
4. Locate the two spark iginition electrode leads connected between the dual-spark iginition module and the two burner  
electrode assemblies that are mounted behind the IFM’s control panel back.  
5. For gaining access to the two burner electrode assemblies, unscrew and remove the control panel followed by the  
control panel back. Unplug both ends of each of the spark iginition electrode leads, one end from the obsolete spark  
module and the other end from the corresponding burner electrode assembly. Discard the two unplugged spark iginition  
electrode leads.  
6. The dual-electrode obsolete spark iginition module is totally disconnected from the IFM circuit. Unscrew and discard  
the module. Also disconnect the wire # 19 from the relight circuit. Unscrew the relight circuit box and discard it.  
Part # 037983  
SpkIgModInst_037981_BB  
9/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S E R V I C E I N S T R U C T I O N S  
Part # 037983  
1-800-KEATING  
INSTALLATION INSTRUCTIONS FOR SPARK  
IGNITION MODULE #037981  
For IFMs With Spark Iginition Module Mounted in the Blower Box  
8. Drill holes and mount the 120V AC DPDT relay with round head screws # 6-32 x 3/8”, # 6-32 hex nuts and internal  
tooth lock washers #6. The location should be in accordance with the two new modules and the length of the wires on  
the wire harness.  
9. Make connections between the two modules by installing the supplied wire harness. Refer to Fig. 2 below for detailed  
wiring. Dashed lines in Fig. 2 show the removed and discarded wires. Dashed lines in Fig. 3 below show the  
added/rewired connections. Solid lines show unaltered wiring in both Fig. 2 and 3.  
FIG 2. WIRING DIAGRAM FOR IFMs WITH DUAL−ELECTRODE SPARK  
IGNITION MODULE (PART # 019724) AND RELIGHT CIRCUIT KIT  
FIG 3. WIRING DIAGRAM FOR IFMs WITH TWO  
SINGLE−ELECTRODE SPARK IGNITION MODULES  
(REPLACEMENT, PART # 037978) AND 120VAC DPDT RELAY  
(PART # 008088)  
10. Connect the 1/4” quick disconnect end of the new spark electrode lead (Part # 037551) to the male tab of the  
single-electrode spark ignition module. Take the other end of the lead to the burner electrode assembly behind the IFM’s  
control panel back. Repeat the same procedure for the other spark electrode lead. Secure the connections.  
11. Re-attach the control panel back followed by the control panel. Screw the blower box cover to the base plate and  
re-assemble all the components.  
SpkIgModInst_037981_BB  
9/08  
Part # 037983  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Insignia Refrigerator NS 4396508 2 User Manual
Intel Network Router 2011B User Manual
Invacare Camping Equipment 1143214 User Manual
Jenn Air Range JGR8895BD User Manual
Jonsered Chainsaw CS 2137 User Manual
Kambrook Fan KFA612 User Manual
Kenmore Gas Grill 415161278 User Manual
Kenwood Computer Monitor DDX4033 User Manual
Keys Fitness Treadmill HT85t User Manual
Kodak Film Camera CIS 174 User Manual