CONTENTS
4
Faults
11
13
13
14
16
Environmental protection
Illustration of the unit
Operating controls
4
5
5
Warranty
General information
Technical data
Spare Parts List
Note on the operating
instructions
6
Commissioning
6
6
6
6
6
6
6
6
7
7
Check the oil level
Filling with scale inhibitor
Filling with fuel
Filling with cleaning agent
Mounting handgun
Mounting handle
Water connection
Drawing in water from tank
Mains connection
Prior to initial operation it is mandatory to
read the operating instructions and the
notes on safety no. 5.951-949!
Inform retailer immediately of any transportation
damage.
Operation
7
7
7
ENVIRONMENTAL PROTECTION
Switching the unit on
Setting cleaning temperature
Setting operating pressure
and flow rate
Measuring out the cleaning
agent
Intended use
Cleaning
Operation with cold water
Operation with hot water
Operation with steam
Safety shut-off
Items used when working, such as fuel, oil,
cleaning agent and contaminated maintenance
materials, are to be deposited at a special
collection point.
7
8
8
8
8
8
8
9
Packaging materials, metal and plastic
containers are to be set aside for recycling as
appropriate.
Disposal of used units
Each time after usage
Reading the operating hours
Shut-down
9
9
9
Your Kärcher retailer will provide you with
information on disposal means harmless to the
environment.
Maintenance
9
Maintenance intervals
9
Maintenance tasks
Indicator lamp (item 28)
motor/electronics module
is lit
Cleaning strainer in water
connection
10
10
10
10
Cleaning strainer in low
water connection
Cleaning filter at
cleaning-agent suction hose
Changing oil
10
10
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
ILLUSTRATION OF THE UNIT
5
CONTROL ELEMENTS
1 Fuel tank inlet
23 Unit switch
2 Handle
3 Instrument panel
24 Temperature regulator
25 Fuel indicator lamp
4 Window with the maintenance/fault display
(only HDS 995, HDS 1295)
5 Cover latch
26 Scale inhibitor indicator lamp
27 Indicator lamp-CHEM 1 , CHEM 2
(only HDS 1295)
6 Compartment für accessories
7 Short operating instructions
8 Cover for compartment
9 Unit cover
28 Indicator lamp-engine
(all machines, except HDS Super)
29 Ready for working indicator lamp
30 Pressure gauge
10 Cover for tank inlet
31 Metering valve for cleaning agent
11 Tank inlet für scale inhibitor
12 tank inlet for cleaning agent
13 High-pressure nozzle
14 Handle grips in the chassis
15 Steel pipe
16 Pressure and flow control
17 Swivel caster with parking brake
18 Water inlet with strainer (coarse)
19 High-pressure connection
20 Handgun with high-pressure hose
22 Electric power cord
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
NOTE ON THE OPERATING INSTRUCTIONS
6
Figure 3
All of the item numbers described below in the
operating instructions are referenced in the
illustration of the unit.
Only fill with diesel fuel or light fuel oil.
It is forbidden to use unsuitable fuels,
e.g. benzine (explosion hazard, damage to
unit).
COMMISSIONING
Close tank cap
Wipe off excess fuel
– Unit, piping, high-pressure hose and
connections must be in perfect working order!
– Lock the hand brake.
Filling with cleaning agent
* Only use Kärcher products.
* Never pour in solvent (petrol, acetone, thinner
etc.)!
Checking oil level
Figure 1
* Avoid contact with eyes and skin
* Pay attention to cleaning-agent
manufacturer's instructions on safety and
handling
Contact Kärcher AFTER-SALES SERVICE
immediately if oil is opaque!
If oil level is approaching MIN mark, fill up with
oil as far as MAX mark.
Kärcher can provide an individual range of
cleaning and treatment agents.
Your dealer will be pleased to advise you.
Seal oil filler inlet.
Refer to technical data for oil grade.
Figure 4
Fill with cleaning agent
Filling with scale inhibitor
Mounting handgun
Figure 2
– Connect steel pipe (item 15) with handgun
(item 20)
– Insert high-pressure nozzle in union nut
– Mount and tighten unit nut
– Mount the high-pressure hose to the high-
pressure connection.(Figure 6)
(sample pack included with scope of delivery)
Scale inhibitor stops heating coil becoming
calcified when using hard tap water. Is is
metered in at the inlet in the water reservoir one
drop at a time.
Mounting of spare high-pressure hose
Figure 5
The metering is set at the factory to medium-
hard water.
For other water hardness classes, call in
Kärcher AFTER-SALES SERVICE to perform
adjustment to local conditions.
Mounting handle
Figure 7
Filling with fuel
– Never operate unit with fuel tank empty! Fuel
pump would otherwise be destroyed!
Water connection
For connected loads, refer to Technical Data.
Install the supply hose to the water inlet
(item 18) of the unit.
(supply hose is not part of scope of delivery)
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
7
Unit starts up briefly and is switched off as soon
as operating pressure is reached.
Drawing in water from tank
When you suction water out of an open
container you should
* Turn the unit off immedediately if during its
operation the indicator lamps
(item 25-item 28) light up. Eliminate fault,
refer to Faults.
– disconnect the water inlet at the pump head.
– unscrew the top supply hose to the water tank
and connect it to the pump head.
– use a water suction hose with a minimum
diameter of 3/4" provided with a vacuum filter.
Figure 8
Release handgun
Actuation of handgun switches unit back on
again.
* Until the pump sucks up water you should:
– turn the pressure and flow regulation to MAX.
– close the metering valve for the cleaning
agent.
Bleed pump if no water emerges from high-
pressure nozzle. Refer to Faults "No build-up of
pressure by unit"
Setting cleaning temperature
– Never suction up water out of a potable water
tank.
Set the temperature regulator (item 24) to the
required temperature
– Never suction up solvent-bearing liquids such
as paint thinner, benzine, oil or unfiltered
water. The seals in the unit are not resistant
to solvents. The mist of solvents is highly
inflammable, explosive and poisonous!
30°C to 90°C
Hot water cleaning
100°C to 150°C
Clean with steam, with steam nozzle -
4.766-023, at HDS 1195 and HDS 1295 -
4.766-024
Mains connection
Refer to technical data and rating plate for
connected loads.
Setting operating pressure and flow rate
Whenever socket is changed, check
direction of rotation of motor
Figure 9
Turning regulator clockwise: Increases
operating pressure (MAX)
Turning counter-clockwise: Reduces operating
pressure (MIN)
If direction of rotation is correct, powerful jet of
air will be felt at exhaust-gas opening of burner.
If the direction of rotation is wrong: Change the
poles at the unit plug. See figure 16.
If an extension cable is used, this should always
be fully uncoiled and have an adequate cross-
section.
Servopress control
Set the temperature regulator (item 24) to
max. 98°C.
Set regulator to maximum operating pressure.
Figure 8
OPERATION
Operating pressure and flow rate can be set at
handgun.
Set pressure on unit if use is to be made of
reduced pressure for a lengthy period.
See figure 9
Switch the unit on
Set the unit switch (item 23) to "I"
The ready for working indicator lamp (item 29)
is lit
The temperature regulator (item 24) must be at
setting "0", since it is otherwise possible that the
burner switches itself on
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
8
Recommended cleaning method
Loosen up dirt:
Measuring out the cleaning agent
Spray on cleaning agent sparingly and allow to
react for 1...5 min (do not allow to dry on).
Remove dirt:
Spray off loosened-up dirt with high-pressure
jet.
* Use cleaning agents sparingly to protect the
environment
* The cleaning agent must be suitable for the
surface to be cleaned.
Set the concentration of the cleaning agent
according to the manufacturer's
recommendations at the cleaning agent
metering valve (item 31)
Operation with cold water
Removal of slight contamination and rinsing
e.g.: Garden implements, terrace, tools, etc.
Approximate values at maximum operating
pressure
Set operating pressure as required
Set the temperature regulator (item 24) to "0"
Intended use
Operation with hot water
Cleaning of: Machines, vehicles, buildings,
tools, facades, terraces, garden tools, etc..
* Danger of scalding
Set the temperature regulator (item 24) to the
required temperature
* Engine cleaning is only to be performed in
areas provided with oil separator.
* Heed appropriate safety regulations for use at
petrol stations or in other hazardous
environments.
We recommend the following cleaning
temperatures
– Slight contamination 30-50°C
– Protein soiling, e.g. in foodstuffs industry
max. 60°C
– Motor vehicle cleaning, machine cleaning
60-90°C
Working with high-pressure nozzle
Spray angle is crucial to efficiency of high-
pressure jet.
Use is normally made of 25°fan jet nozzle
(included).
Operation with steam
Recommended nozzles, available as
accessories
– For stubborn dirt 0°full jet nozzle
At operating temperatures above 98°C
operating pressure must not exceed 32 bar.
Therefore the standard high-pressure nozzle
must be replaced by the steam nozzle
(manufacture no.: 4.766-023, for HDS 1195
and HDS 1295 4.766-024.0; see accessories).
– For delicate surfaces and slight contamination
40°fan jet nozzle
– For thick layers of stubborn dirt dirt blaster
– Set operating pressure to minimum value.
See figure 9
– Set the temperature regulator (item 24) to
min. 100°C
– Nozzle with variable spray angle, for
adaptation to various cleaning tasks variable-
angle nozzle
* Danger of scalding!
Cleaning
* Set pressure/temperature and cleaning-agent
concentration in line with surface to be
cleaned
* Always start by directing high-pressure jet
from a good distance at object to be cleaned
to avoid damage caused by excessive
pressure.
We recommend the following cleaning
temperatures
– Preservative removal, extremely greasy dirt
100-110°C
– Thawing of aggregates, certain facade
cleaning operations up to 140°C
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
9
Safety shut-off
DISCONTINUATION OF USAGE
The pump automatically shuts down for safety
reasons if the handgun is neither opened or
closed for more than 30 minutes.
– To switch it on again turn the main switch to
"0" and then back to the "I" position.
(The EPROM without disabling 6.682-595.0 is
available from service)
In the event of lengthy periods of non-use or if
frost-free storage is not possible:
– Drain off water and flush out equipment with
antifreeze
– Drain cleaning fluid tank
Drain off water
– Unscrew water supply hose and high-
pressure hose
– Unscrew supply line at boiler base and allow
heating coil to drain
– Run unit for max. 1 min until pump and lines
are empty
EACH TIME AFTER USAGE
Following operation with cleaning agent
– Set the cleaning agent metering valve
(item 31) to "0"
– Set the unit switch (item 23) to "I"
– Actuate handgun and flush unit for
approx. 1 min
Flushing unit with anti-freeze
– Fill the float tank with a commercially
available antifreezing compound
– Swith the unit on (without the burner) until it is
thoroughly purged
– Observe handling instructions of antifreeze
manufacturer
– By this means, a certain degree of corrosion
protection is achieved
Stopping machine
– Set the unit switch (item 23) to "0"
– Shut off water supply
– Switch the pump briefly on with the unit switch
(item 23) (approx. 5 sec.)
– Remove mains plug from socket ONLY with
dry hands
– Detach water connection
– Actuate handgun to depressurise unit
MAINTENANCE
– Lock the hand spray gun Figure 8
– Engage spray lance in cover holder
– Reel up the high-pressure hose and electric
cables and attach them to fastenings
* Disconnect unit from mains before carrying
out any maintenance or repair work.
* Always use genuine spare parts
Shut off unit before performing any work, refer
to AFTER USE.
* Take care not to kink high-pressure hose and
cable!
Set the unit switch (item 23) to "0"
Pull power plug out of socket
Shut off water supply
Actuate handgun to depressurise unit.
Detach water connection
Frost will destroy unit if water is not drained off
completely!
Store unit in a frost-free location
Allow unit to cool down
Take unit out of service if frost-free storage is
not possible.
Please consult your Kärcher dealer for
details of regular safety
inspection/maintenance agreement
READING THE OPERATING HOURS
(ONLY HDS 995 AND HDS 1295)
Maintenance intervals
When you open the storage compartment cover
flap,you will notice the electronic operating
hours display in the viewing window, e.g.
Once a week
– Clean strainer in water connection
– Check oil level
= 245 hours.
Contact Kärcher AFTER-SALES SERVICE
immediately if oil is opaque!
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
10
Once a month
Display
– Clean strainer in low water protection
– Clean filter at cleaning-agent suction hose
Necessary maintenance work
– Check the overflow valve for leaks *
– Check the high-pressure hose *
– Clean the handgun
After 500 hours of operation, at least once a
year
– Change oil
– Check the pulsation damper *
* This maintenance work should be performed
only by after-sales service.
MAINTENANCE TASKS
Cleaning strainer in water connection
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
The indicator lamp (item.28)
motor/electronics module is lit
(only HDS 995 and HDS 1295)
Figure 10
– Remove strainer
– Clean in water and re-insert
* This warning lamp lights up when certain
maintenance work is necessary due to
accumulated operating hours.
* When you open the cover (item 8) of the
compartment (item 6) the electronic display is
visible in the window (item 4).
Cleaning strainer in low water protection
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Figure 11
– Unfasten union nut and detach hose
* Upon completing the necessary maintenance
work the RESET button next to the display
must be depressed at least 7 seconds until
the warning lamp goes out.
Figure 12
– Take out strainer
If necessary, screw in bolt M8 approx. 5mm to
pull out strainer.
Display
– Clean strainer in water
– Slide in strainer
– Mount hose
Necessary maintenance work
– Visual inspection
– Check that the high-pressure connections do
not leak
– Tighten union nut
– Clean the fuel tank and the filter
Cleaning filter at cleaning-agent suction
hose
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
Display
HDS 1195, HDS 1295, HDS Super)
Necessary maintenance work
– Check that the pump does not leak
– Change the pump's oil
– Clean strainer in water connection
– Clean the strainer (coarse) fitted in front of the
low water protection
Figure 13
– Pull the cleaning agent suction inlet pipe out
– Clean filter in water and re-insert
Changing oil
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Display
Figure 14
Necessary maintenance work
– Decarbonise the heating coil *
– Descale the heating coil *
– Clean/replace the ignition electrodes *
– Clean/replace the burner jet *
– Adjust the burner *
– Provide a collecting container for approx. 1
litres of oil
– Loosen starting screw
* Dispose of used oil in appropriate manner or
hand in at a collection point.
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
11
– Tighten drain plug again
– Slowly fill with oil as far as MAX mark
Air bubbles must be able to escape
Refer to technical data for oil grade and quantity
to be used.
Display
Troubleshooting
This error code appears only on units
equipped with the – accessory kit flame
monitoring system -
FAULTS
See the assembly instructions – accessory
kit flame monitoring system -
The indicator lamp- MOTOR/ELECTRONICS
MODULE (item 28) flashes
(only HDS 995 and HDS 1295)
* This maintenance work should be performed
only by after-sales service.
* This warning lamp flashes if there is a
problem.
The READY FOR WORKING indicator lamp
(item 28) goes out
(HDS 745, HDS 695 S, HDS 895 S, HDS 1195,
HDS Super)
* When you open the cover (item 8) of the
compartment (item 6) the electronic display is
visible in the window (item 4).
Motor overloaded/overheated
– Set selector switch to "0" and allow motor to
cool down for at least 5 min.
– Have unit checked by After-Sales Service if
this does not remedy fault.
– No mains voltage (see – unit does not run -)
* The warning lamp goes out when the problem
has been resolved and the unit is switched on
again.
Display
The FUEL indicator lamp (item 25) is lit
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Troubleshooting
– Increase the water inlet volume
– Clean strainer in water connection
Fuel tank empty
– Clean the strainer (coarse) fitted in front of the – Fill up
low water protection
The READY FOR WORKING indicator lamp
(item 29) goes out
Display
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Troubleshooting
– Replace the reed switch for the low water
protection *
– Clean the low water protection *
Engine is overloaded
– Set selector switch to "0" and allow motor to
cool down for at least 5 min.
– Have unit checked by After-Sales Service if
this does not remedy fault.
Display
– No mains voltage (see – unit does not run -)
Troubleshooting
– Eliminate the leakage in the high-pressure
system
SCALE INHIBITOR indicator lamp (item 26)
is lit
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Display
Scale inhibitor reservoir empty; for technical
reasons there is always a residual quantity in
the reservoir.
Troubleshooting
Motor is overloaded/overheated
– Set the monitoring switch to "0" and allow the
motor to cool off for at least 5 min
– Have unit checked by After-Sales Service if
this does not remedy fault
– Fill up
Dirt on electrodes in reservoir
– Clean electrodes
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
12
the float tank is suctioned empty and the
pressure drops to "0".
Unit does not run
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
– Now reopen the water inlet.
If the pump still does not suction up cleaning
agent the reasons can be as follows:
Filter in cleaning-agent suction hose dirty
– Clean filter
No mains voltage
– Check mains connection/power cord
Unit does not build up pressure
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Non-return valve gummed up
– Pull the cleaning agent hose off and detach
the non-return valve with a blunt object, see
Figure 15.
Air in system
– Bleed pump:
* Set the cleaning agent metering valve
(item 31) to "0"
* While the handgun is open switch the unit on
and off several times with the unit switch.
* With handgun open, open and close regulator
(Figure 9).
Burner not ignited
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Fuel tank empty
– Fill up
* Venting is accelerated by removing the high-
pressure hose from the high-pressure
connection.
– Fill up cleaning-agent tank if empty.
– Check connections and lines
Lack of water
– Check water connection, check supply lines,
clean low water protection.
Fuel filter dirty
– Replace fuel filter.
Pressure set to MIN
– Set pressure to MAX
Incorrect direction of rotation. If direction of
rotation is correct, powerful jet of air will be felt
at exhaust-gas opening of burner.
– Check direction of rotation. If
necessary change the poles at the unit plug.
See figure 16.
Strainer in water connection dirty
– Clean strainer
Insufficient water supply
– Check water supply volume
(refer to technical data)
–
No ignition spark
Unit leaking, water dripping out at bottom
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
– Have unit checked by After-Sales Service if
no ignition spark is visible through inspection
glass during operation.
Pump leaking
– 3 droplets/min are permitted.
– In the event of a major leak, have unit
checked by After-Sales Service.
Set temperature not attained when working
with hot water
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Unit constantly switched on and off with
handgun closed
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
Excessive operating pressure/flow rate
– Reduce operating pressure/flow rate by way
of regulator (Figure 9)
HDS 1195, HDS 1295, HDS Super)
Soot deposits on heating coil
– Have After-Sales Service remove soot
deposits from unit
Leak in high-pressure system
– Check high-pressure system and connections
for leaks
If the problem cannot be resolved the unit
must be checked by after sales service.
Unit does not draw in cleaning agent
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,
HDS 1195, HDS 1295, HDS Super)
Operate the unit with an opened cleaning agent
metering valve and a shut off water inlet until
Download from Www.Somanuals.com. All Manuals Search And Download.
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295
13
Guidelines for liquid spraying equipment
WARRANTY
* The accident prevention directive (BGV D 15)
Work with Jets of Liquids is applicable. In
accordance with these guidelines, high-
pressure spraying equipment must be
checked at least every 12 months by an
expert and the results of the inspection
recorded in writing.
The warranty terms and conditions issued by
our responsible sales company apply in every
country. Within the warranty period, any faults in
the unit will be rectified free of charge provided
that the problem was caused by a material
defect or manufacturing error.
Order governing boilers
The warranty only applies if the dealer fills in,
stamps and signs the enclosed reply card when
the unit is sold and the purchaser then returns it
to the appropriate local distributor.
* The testing pressure and the design of the
unit comply with the steam boiler directive!.
The water content of the heating coil is less
than 10 litres. The boiler section of the unit is
thus not subject to installation regulations.
Local building regulations are to be heeded.
In the event of a warranty claim, please contact
your dealer or the nearest authorised After-
Sales Service office and produce both
accessories and proof of purchase.
Switching on procedures
* Switching on procedures generate brief
voltage drops. Impairments of other
appliances can occur in cases of
unfavourable mains conditions. No problems
are to be expected with a mains impedance of
less than 0,15 ohm.
GENERAL INSTRUCTIONS
Safety features
* Overflow valve with two pressure switches
When reducing water volume at pump head or
with the servopress control, the overflow valve
will open and part of the water will flow back to
the pump suction side.
If the handgun is closed thus causing all the
water to return to the pump suction end, the
pressure switch at the overflow valve shuts off
the pump.
Reopening the handgun causes the pressure
switch at the cylinder head to switch the pump
back on again.
The overflow valve is set at the factory and
lead-sealed. Adjustment can only be made by
After-Sales Service.
* Safety valve
The safety valve opens if the overflow valve or
pressure switch is defective. The safety valve is
set at the factory and sealed. Adjustment can
only be made by After-Sales Service.
* Low water protection
The low water protection stops the burner being
switched on in the event of a lack of water. A
strainer stops the protection feature becoming
dirty and requires regular cleaning.
* Motor protection switch
The motor protection switch interrupts the circuit
should overloading occur.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 16
Download from Www.Somanuals.com. All Manuals Search And Download.
EU DECLARATION OF CONFORMITY
We hereby declare that the equipment described below
conforms to the relevant fundamental safety and health
requirements of the appropriate EU Directives, both in its
basic design and construction as well as in the version
marketed by us. This declaration will cease to be valid if any
modifications are made to the machine without our express
approval.
Product: High-pressure cleaner with steam stage
Model: 1.025-xxx, 1.026-xxx, 1.027-xxx, 1.028-xxx
Relevant EU Directives:
EU Machinery Directive (98/37/EG); EU Low-Voltage
Equipment Directive (73/23/EWG)amended by 93/68/EWG;
EU Directive on Electromagnetic Compatibility (89/336/EWG)
amended by 91/263/EWG, 92/31/EWG, 93/68/EWG
EU - pressure-operated units regulations (97/23/EG)
Harmonised standards applied:
DIN EN 60 335-1, DIN EN 60 335-2-79,
DIN EN 55 014-1:1999, DIN EN 55 014-2:1997,
DIN EN 61 000-3-2:1995, DIN EN 61 000-3-3:1995
Relevant EU Directives:
TRD 801, TRD 301, DIN 2413
Appropriate internal measures have been taken to ensure that
series-production units conform at all times to the
requirements of current EU Directives and relevant standards.
The signatories are empowered to represent and act on
behalf of the company management.
5.957-649 (07/01)
Alfred Kärcher Limited Partnership.
Registered office: Winnenden. Company Register:
Waiblingen, HRA 169.
Personally liable partner. Kärcher Reinigungstechnik GmbH.
Registered office Winnenden, 2404 Waiblingen Company
Register, HRB
Managing directors:
Dr. Bernhard Graf, Hartmut Jenner, Roland Kamm,
Herbert Konhäusner, Georg Metz, Thomas Schöbinger
Alfred Kärcher GmbH & Co.
Cleaning Systems
Alfred-Kärcher-Straße 28-40
P.O.Box 160
D-71349 Winnenden, Germany
Phone: ++49 7195 14-0
Fax :++49 7195 14-2212
( Graf
Reiser
Schöbinger )
Download from Www.Somanuals.com. All Manuals Search And Download.
|