Karcher Pressure Washer HDS 1195 User Manual

HDS Super  
HDS 695 S  
HDS 745  
HDS 895 S  
HDS 995  
HDS 1195  
HDS 1295  
5.959 - 788 A2002029 (07/01)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HD S Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
13  
3
9
10  
11  
12  
14  
15  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
CONTENTS  
4
Faults  
11  
13  
13  
14  
16  
Environmental protection  
Illustration of the unit  
Operating controls  
4
5
5
Warranty  
General information  
Technical data  
Spare Parts List  
Note on the operating  
instructions  
6
Commissioning  
6
6
6
6
6
6
6
6
7
7
Check the oil level  
Filling with scale inhibitor  
Filling with fuel  
Filling with cleaning agent  
Mounting handgun  
Mounting handle  
Water connection  
Drawing in water from tank  
Mains connection  
Prior to initial operation it is mandatory to  
read the operating instructions and the  
notes on safety no. 5.951-949!  
Inform retailer immediately of any transportation  
damage.  
Operation  
7
7
7
ENVIRONMENTAL PROTECTION  
Switching the unit on  
Setting cleaning temperature  
Setting operating pressure  
and flow rate  
Measuring out the cleaning  
agent  
Intended use  
Cleaning  
Operation with cold water  
Operation with hot water  
Operation with steam  
Safety shut-off  
Items used when working, such as fuel, oil,  
cleaning agent and contaminated maintenance  
materials, are to be deposited at a special  
collection point.  
7
8
8
8
8
8
8
9
Packaging materials, metal and plastic  
containers are to be set aside for recycling as  
appropriate.  
Disposal of used units  
Each time after usage  
Reading the operating hours  
Shut-down  
9
9
9
Your Kärcher retailer will provide you with  
information on disposal means harmless to the  
environment.  
Maintenance  
9
Maintenance intervals  
9
Maintenance tasks  
Indicator lamp (item 28)  
motor/electronics module  
is lit  
Cleaning strainer in water  
connection  
10  
10  
10  
10  
Cleaning strainer in low  
water connection  
Cleaning filter at  
cleaning-agent suction hose  
Changing oil  
10  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
ILLUSTRATION OF THE UNIT  
5
CONTROL ELEMENTS  
1 Fuel tank inlet  
23 Unit switch  
2 Handle  
3 Instrument panel  
24 Temperature regulator  
25 Fuel indicator lamp  
4 Window with the maintenance/fault display  
(only HDS 995, HDS 1295)  
5 Cover latch  
26 Scale inhibitor indicator lamp  
27 Indicator lamp-CHEM 1 , CHEM 2  
(only HDS 1295)  
6 Compartment für accessories  
7 Short operating instructions  
8 Cover for compartment  
9 Unit cover  
28 Indicator lamp-engine  
(all machines, except HDS Super)  
29 Ready for working indicator lamp  
30 Pressure gauge  
10 Cover for tank inlet  
31 Metering valve for cleaning agent  
11 Tank inlet für scale inhibitor  
12 tank inlet for cleaning agent  
13 High-pressure nozzle  
14 Handle grips in the chassis  
15 Steel pipe  
16 Pressure and flow control  
17 Swivel caster with parking brake  
18 Water inlet with strainer (coarse)  
19 High-pressure connection  
20 Handgun with high-pressure hose  
22 Electric power cord  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
NOTE ON THE OPERATING INSTRUCTIONS  
6
Figure 3  
All of the item numbers described below in the  
operating instructions are referenced in the  
illustration of the unit.  
Only fill with diesel fuel or light fuel oil.  
It is forbidden to use unsuitable fuels,  
e.g. benzine (explosion hazard, damage to  
unit).  
COMMISSIONING  
Close tank cap  
Wipe off excess fuel  
Unit, piping, high-pressure hose and  
connections must be in perfect working order!  
Lock the hand brake.  
Filling with cleaning agent  
* Only use Kärcher products.  
* Never pour in solvent (petrol, acetone, thinner  
etc.)!  
Checking oil level  
Figure 1  
* Avoid contact with eyes and skin  
* Pay attention to cleaning-agent  
manufacturer's instructions on safety and  
handling  
Contact Kärcher AFTER-SALES SERVICE  
immediately if oil is opaque!  
If oil level is approaching MIN mark, fill up with  
oil as far as MAX mark.  
Kärcher can provide an individual range of  
cleaning and treatment agents.  
Your dealer will be pleased to advise you.  
Seal oil filler inlet.  
Refer to technical data for oil grade.  
Figure 4  
Fill with cleaning agent  
Filling with scale inhibitor  
Mounting handgun  
Figure 2  
Connect steel pipe (item 15) with handgun  
(item 20)  
Insert high-pressure nozzle in union nut  
Mount and tighten unit nut  
Mount the high-pressure hose to the high-  
pressure connection.(Figure 6)  
(sample pack included with scope of delivery)  
Scale inhibitor stops heating coil becoming  
calcified when using hard tap water. Is is  
metered in at the inlet in the water reservoir one  
drop at a time.  
Mounting of spare high-pressure hose  
Figure 5  
The metering is set at the factory to medium-  
hard water.  
For other water hardness classes, call in  
Kärcher AFTER-SALES SERVICE to perform  
adjustment to local conditions.  
Mounting handle  
Figure 7  
Filling with fuel  
Never operate unit with fuel tank empty! Fuel  
pump would otherwise be destroyed!  
Water connection  
For connected loads, refer to Technical Data.  
Install the supply hose to the water inlet  
(item 18) of the unit.  
(supply hose is not part of scope of delivery)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
7
Unit starts up briefly and is switched off as soon  
as operating pressure is reached.  
Drawing in water from tank  
When you suction water out of an open  
container you should  
* Turn the unit off immedediately if during its  
operation the indicator lamps  
(item 25-item 28) light up. Eliminate fault,  
refer to Faults.  
disconnect the water inlet at the pump head.  
unscrew the top supply hose to the water tank  
and connect it to the pump head.  
use a water suction hose with a minimum  
diameter of 3/4" provided with a vacuum filter.  
Figure 8  
Release handgun  
Actuation of handgun switches unit back on  
again.  
* Until the pump sucks up water you should:  
turn the pressure and flow regulation to MAX.  
close the metering valve for the cleaning  
agent.  
Bleed pump if no water emerges from high-  
pressure nozzle. Refer to Faults "No build-up of  
pressure by unit"  
Setting cleaning temperature  
Never suction up water out of a potable water  
tank.  
Set the temperature regulator (item 24) to the  
required temperature  
Never suction up solvent-bearing liquids such  
as paint thinner, benzine, oil or unfiltered  
water. The seals in the unit are not resistant  
to solvents. The mist of solvents is highly  
inflammable, explosive and poisonous!  
30°C to 90°C  
Hot water cleaning  
100°C to 150°C  
Clean with steam, with steam nozzle -  
4.766-023, at HDS 1195 and HDS 1295 -  
4.766-024  
Mains connection  
Refer to technical data and rating plate for  
connected loads.  
Setting operating pressure and flow rate  
Whenever socket is changed, check  
direction of rotation of motor  
Figure 9  
Turning regulator clockwise: Increases  
operating pressure (MAX)  
Turning counter-clockwise: Reduces operating  
pressure (MIN)  
If direction of rotation is correct, powerful jet of  
air will be felt at exhaust-gas opening of burner.  
If the direction of rotation is wrong: Change the  
poles at the unit plug. See figure 16.  
If an extension cable is used, this should always  
be fully uncoiled and have an adequate cross-  
section.  
Servopress control  
Set the temperature regulator (item 24) to  
max. 98°C.  
Set regulator to maximum operating pressure.  
Figure 8  
OPERATION  
Operating pressure and flow rate can be set at  
handgun.  
Set pressure on unit if use is to be made of  
reduced pressure for a lengthy period.  
See figure 9  
Switch the unit on  
Set the unit switch (item 23) to "I"  
The ready for working indicator lamp (item 29)  
is lit  
The temperature regulator (item 24) must be at  
setting "0", since it is otherwise possible that the  
burner switches itself on  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
8
Recommended cleaning method  
Loosen up dirt:  
Measuring out the cleaning agent  
Spray on cleaning agent sparingly and allow to  
react for 1...5 min (do not allow to dry on).  
Remove dirt:  
Spray off loosened-up dirt with high-pressure  
jet.  
* Use cleaning agents sparingly to protect the  
environment  
* The cleaning agent must be suitable for the  
surface to be cleaned.  
Set the concentration of the cleaning agent  
according to the manufacturer's  
recommendations at the cleaning agent  
metering valve (item 31)  
Operation with cold water  
Removal of slight contamination and rinsing  
e.g.: Garden implements, terrace, tools, etc.  
Approximate values at maximum operating  
pressure  
Set operating pressure as required  
Set the temperature regulator (item 24) to "0"  
Intended use  
Operation with hot water  
Cleaning of: Machines, vehicles, buildings,  
tools, facades, terraces, garden tools, etc..  
* Danger of scalding  
Set the temperature regulator (item 24) to the  
required temperature  
* Engine cleaning is only to be performed in  
areas provided with oil separator.  
* Heed appropriate safety regulations for use at  
petrol stations or in other hazardous  
environments.  
We recommend the following cleaning  
temperatures  
Slight contamination 30-50°C  
Protein soiling, e.g. in foodstuffs industry  
max. 60°C  
Motor vehicle cleaning, machine cleaning  
60-90°C  
Working with high-pressure nozzle  
Spray angle is crucial to efficiency of high-  
pressure jet.  
Use is normally made of 25°fan jet nozzle  
(included).  
Operation with steam  
Recommended nozzles, available as  
accessories  
For stubborn dirt 0°full jet nozzle  
At operating temperatures above 98°C  
operating pressure must not exceed 32 bar.  
Therefore the standard high-pressure nozzle  
must be replaced by the steam nozzle  
(manufacture no.: 4.766-023, for HDS 1195  
and HDS 1295 4.766-024.0; see accessories).  
For delicate surfaces and slight contamination  
40°fan jet nozzle  
For thick layers of stubborn dirt dirt blaster  
Set operating pressure to minimum value.  
See figure 9  
Set the temperature regulator (item 24) to  
min. 100°C  
Nozzle with variable spray angle, for  
adaptation to various cleaning tasks variable-  
angle nozzle  
* Danger of scalding!  
Cleaning  
* Set pressure/temperature and cleaning-agent  
concentration in line with surface to be  
cleaned  
* Always start by directing high-pressure jet  
from a good distance at object to be cleaned  
to avoid damage caused by excessive  
pressure.  
We recommend the following cleaning  
temperatures  
Preservative removal, extremely greasy dirt  
100-110°C  
Thawing of aggregates, certain facade  
cleaning operations up to 140°C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
9
Safety shut-off  
DISCONTINUATION OF USAGE  
The pump automatically shuts down for safety  
reasons if the handgun is neither opened or  
closed for more than 30 minutes.  
To switch it on again turn the main switch to  
"0" and then back to the "I" position.  
(The EPROM without disabling 6.682-595.0 is  
available from service)  
In the event of lengthy periods of non-use or if  
frost-free storage is not possible:  
Drain off water and flush out equipment with  
antifreeze  
Drain cleaning fluid tank  
Drain off water  
Unscrew water supply hose and high-  
pressure hose  
Unscrew supply line at boiler base and allow  
heating coil to drain  
Run unit for max. 1 min until pump and lines  
are empty  
EACH TIME AFTER USAGE  
Following operation with cleaning agent  
Set the cleaning agent metering valve  
(item 31) to "0"  
Set the unit switch (item 23) to "I"  
Actuate handgun and flush unit for  
approx. 1 min  
Flushing unit with anti-freeze  
Fill the float tank with a commercially  
available antifreezing compound  
Swith the unit on (without the burner) until it is  
thoroughly purged  
Observe handling instructions of antifreeze  
manufacturer  
By this means, a certain degree of corrosion  
protection is achieved  
Stopping machine  
Set the unit switch (item 23) to "0"  
Shut off water supply  
Switch the pump briefly on with the unit switch  
(item 23) (approx. 5 sec.)  
Remove mains plug from socket ONLY with  
dry hands  
Detach water connection  
Actuate handgun to depressurise unit  
MAINTENANCE  
Lock the hand spray gun Figure 8  
Engage spray lance in cover holder  
Reel up the high-pressure hose and electric  
cables and attach them to fastenings  
* Disconnect unit from mains before carrying  
out any maintenance or repair work.  
* Always use genuine spare parts  
Shut off unit before performing any work, refer  
to AFTER USE.  
* Take care not to kink high-pressure hose and  
cable!  
Set the unit switch (item 23) to "0"  
Pull power plug out of socket  
Shut off water supply  
Actuate handgun to depressurise unit.  
Detach water connection  
Frost will destroy unit if water is not drained off  
completely!  
Store unit in a frost-free location  
Allow unit to cool down  
Take unit out of service if frost-free storage is  
not possible.  
Please consult your Kärcher dealer for  
details of regular safety  
inspection/maintenance agreement  
READING THE OPERATING HOURS  
(ONLY HDS 995 AND HDS 1295)  
Maintenance intervals  
When you open the storage compartment cover  
flap,you will notice the electronic operating  
hours display in the viewing window, e.g.  
Once a week  
Clean strainer in water connection  
Check oil level  
= 245 hours.  
Contact Kärcher AFTER-SALES SERVICE  
immediately if oil is opaque!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
10  
Once a month  
Display  
Clean strainer in low water protection  
Clean filter at cleaning-agent suction hose  
Necessary maintenance work  
Check the overflow valve for leaks *  
Check the high-pressure hose *  
Clean the handgun  
After 500 hours of operation, at least once a  
year  
Change oil  
Check the pulsation damper *  
* This maintenance work should be performed  
only by after-sales service.  
MAINTENANCE TASKS  
Cleaning strainer in water connection  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
The indicator lamp (item.28)  
motor/electronics module is lit  
(only HDS 995 and HDS 1295)  
Figure 10  
Remove strainer  
Clean in water and re-insert  
* This warning lamp lights up when certain  
maintenance work is necessary due to  
accumulated operating hours.  
* When you open the cover (item 8) of the  
compartment (item 6) the electronic display is  
visible in the window (item 4).  
Cleaning strainer in low water protection  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Figure 11  
Unfasten union nut and detach hose  
* Upon completing the necessary maintenance  
work the RESET button next to the display  
must be depressed at least 7 seconds until  
the warning lamp goes out.  
Figure 12  
Take out strainer  
If necessary, screw in bolt M8 approx. 5mm to  
pull out strainer.  
Display  
Clean strainer in water  
Slide in strainer  
Mount hose  
Necessary maintenance work  
Visual inspection  
Check that the high-pressure connections do  
not leak  
Tighten union nut  
Clean the fuel tank and the filter  
Cleaning filter at cleaning-agent suction  
hose  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
Display  
HDS 1195, HDS 1295, HDS Super)  
Necessary maintenance work  
Check that the pump does not leak  
Change the pump's oil  
Clean strainer in water connection  
Clean the strainer (coarse) fitted in front of the  
low water protection  
Figure 13  
Pull the cleaning agent suction inlet pipe out  
Clean filter in water and re-insert  
Changing oil  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Display  
Figure 14  
Necessary maintenance work  
Decarbonise the heating coil *  
Descale the heating coil *  
Clean/replace the ignition electrodes *  
Clean/replace the burner jet *  
Adjust the burner *  
Provide a collecting container for approx. 1  
litres of oil  
Loosen starting screw  
* Dispose of used oil in appropriate manner or  
hand in at a collection point.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
11  
Tighten drain plug again  
Slowly fill with oil as far as MAX mark  
Air bubbles must be able to escape  
Refer to technical data for oil grade and quantity  
to be used.  
Display  
Troubleshooting  
This error code appears only on units  
equipped with the – accessory kit flame  
monitoring system -  
FAULTS  
See the assembly instructions – accessory  
kit flame monitoring system -  
The indicator lamp- MOTOR/ELECTRONICS  
MODULE (item 28) flashes  
(only HDS 995 and HDS 1295)  
* This maintenance work should be performed  
only by after-sales service.  
* This warning lamp flashes if there is a  
problem.  
The READY FOR WORKING indicator lamp  
(item 28) goes out  
(HDS 745, HDS 695 S, HDS 895 S, HDS 1195,  
HDS Super)  
* When you open the cover (item 8) of the  
compartment (item 6) the electronic display is  
visible in the window (item 4).  
Motor overloaded/overheated  
Set selector switch to "0" and allow motor to  
cool down for at least 5 min.  
Have unit checked by After-Sales Service if  
this does not remedy fault.  
No mains voltage (see – unit does not run -)  
* The warning lamp goes out when the problem  
has been resolved and the unit is switched on  
again.  
Display  
The FUEL indicator lamp (item 25) is lit  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Troubleshooting  
Increase the water inlet volume  
Clean strainer in water connection  
Fuel tank empty  
Clean the strainer (coarse) fitted in front of the Fill up  
low water protection  
The READY FOR WORKING indicator lamp  
(item 29) goes out  
Display  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Troubleshooting  
Replace the reed switch for the low water  
protection *  
Clean the low water protection *  
Engine is overloaded  
Set selector switch to "0" and allow motor to  
cool down for at least 5 min.  
Have unit checked by After-Sales Service if  
this does not remedy fault.  
Display  
No mains voltage (see – unit does not run -)  
Troubleshooting  
Eliminate the leakage in the high-pressure  
system  
SCALE INHIBITOR indicator lamp (item 26)  
is lit  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Display  
Scale inhibitor reservoir empty; for technical  
reasons there is always a residual quantity in  
the reservoir.  
Troubleshooting  
Motor is overloaded/overheated  
Set the monitoring switch to "0" and allow the  
motor to cool off for at least 5 min  
Have unit checked by After-Sales Service if  
this does not remedy fault  
Fill up  
Dirt on electrodes in reservoir  
Clean electrodes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
12  
the float tank is suctioned empty and the  
pressure drops to "0".  
Unit does not run  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Now reopen the water inlet.  
If the pump still does not suction up cleaning  
agent the reasons can be as follows:  
Filter in cleaning-agent suction hose dirty  
Clean filter  
No mains voltage  
Check mains connection/power cord  
Unit does not build up pressure  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Non-return valve gummed up  
Pull the cleaning agent hose off and detach  
the non-return valve with a blunt object, see  
Figure 15.  
Air in system  
Bleed pump:  
* Set the cleaning agent metering valve  
(item 31) to "0"  
* While the handgun is open switch the unit on  
and off several times with the unit switch.  
* With handgun open, open and close regulator  
(Figure 9).  
Burner not ignited  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Fuel tank empty  
Fill up  
* Venting is accelerated by removing the high-  
pressure hose from the high-pressure  
connection.  
Fill up cleaning-agent tank if empty.  
Check connections and lines  
Lack of water  
Check water connection, check supply lines,  
clean low water protection.  
Fuel filter dirty  
Replace fuel filter.  
Pressure set to MIN  
Set pressure to MAX  
Incorrect direction of rotation. If direction of  
rotation is correct, powerful jet of air will be felt  
at exhaust-gas opening of burner.  
Check direction of rotation. If  
necessary change the poles at the unit plug.  
See figure 16.  
Strainer in water connection dirty  
Clean strainer  
Insufficient water supply  
Check water supply volume  
(refer to technical data)  
No ignition spark  
Unit leaking, water dripping out at bottom  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Have unit checked by After-Sales Service if  
no ignition spark is visible through inspection  
glass during operation.  
Pump leaking  
3 droplets/min are permitted.  
In the event of a major leak, have unit  
checked by After-Sales Service.  
Set temperature not attained when working  
with hot water  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Unit constantly switched on and off with  
handgun closed  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
Excessive operating pressure/flow rate  
Reduce operating pressure/flow rate by way  
of regulator (Figure 9)  
HDS 1195, HDS 1295, HDS Super)  
Soot deposits on heating coil  
Have After-Sales Service remove soot  
deposits from unit  
Leak in high-pressure system  
Check high-pressure system and connections  
for leaks  
If the problem cannot be resolved the unit  
must be checked by after sales service.  
Unit does not draw in cleaning agent  
(HDS 745, HDS 695 S, HDS 895 S, HDS 995,  
HDS 1195, HDS 1295, HDS Super)  
Operate the unit with an opened cleaning agent  
metering valve and a shut off water inlet until  
Download from Www.Somanuals.com. All Manuals Search And Download.  
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295  
13  
Guidelines for liquid spraying equipment  
WARRANTY  
* The accident prevention directive (BGV D 15)  
Work with Jets of Liquids is applicable. In  
accordance with these guidelines, high-  
pressure spraying equipment must be  
checked at least every 12 months by an  
expert and the results of the inspection  
recorded in writing.  
The warranty terms and conditions issued by  
our responsible sales company apply in every  
country. Within the warranty period, any faults in  
the unit will be rectified free of charge provided  
that the problem was caused by a material  
defect or manufacturing error.  
Order governing boilers  
The warranty only applies if the dealer fills in,  
stamps and signs the enclosed reply card when  
the unit is sold and the purchaser then returns it  
to the appropriate local distributor.  
* The testing pressure and the design of the  
unit comply with the steam boiler directive!.  
The water content of the heating coil is less  
than 10 litres. The boiler section of the unit is  
thus not subject to installation regulations.  
Local building regulations are to be heeded.  
In the event of a warranty claim, please contact  
your dealer or the nearest authorised After-  
Sales Service office and produce both  
accessories and proof of purchase.  
Switching on procedures  
* Switching on procedures generate brief  
voltage drops. Impairments of other  
appliances can occur in cases of  
unfavourable mains conditions. No problems  
are to be expected with a mains impedance of  
less than 0,15 ohm.  
GENERAL INSTRUCTIONS  
Safety features  
* Overflow valve with two pressure switches  
When reducing water volume at pump head or  
with the servopress control, the overflow valve  
will open and part of the water will flow back to  
the pump suction side.  
If the handgun is closed thus causing all the  
water to return to the pump suction end, the  
pressure switch at the overflow valve shuts off  
the pump.  
Reopening the handgun causes the pressure  
switch at the cylinder head to switch the pump  
back on again.  
The overflow valve is set at the factory and  
lead-sealed. Adjustment can only be made by  
After-Sales Service.  
* Safety valve  
The safety valve opens if the overflow valve or  
pressure switch is defective. The safety valve is  
set at the factory and sealed. Adjustment can  
only be made by After-Sales Service.  
* Low water protection  
The low water protection stops the burner being  
switched on in the event of a lack of water. A  
strainer stops the protection feature becoming  
dirty and requires regular cleaning.  
* Motor protection switch  
The motor protection switch interrupts the circuit  
should overloading occur.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EU DECLARATION OF CONFORMITY  
We hereby declare that the equipment described below  
conforms to the relevant fundamental safety and health  
requirements of the appropriate EU Directives, both in its  
basic design and construction as well as in the version  
marketed by us. This declaration will cease to be valid if any  
modifications are made to the machine without our express  
approval.  
Product: High-pressure cleaner with steam stage  
Model: 1.025-xxx, 1.026-xxx, 1.027-xxx, 1.028-xxx  
Relevant EU Directives:  
EU Machinery Directive (98/37/EG); EU Low-Voltage  
Equipment Directive (73/23/EWG)amended by 93/68/EWG;  
EU Directive on Electromagnetic Compatibility (89/336/EWG)  
amended by 91/263/EWG, 92/31/EWG, 93/68/EWG  
EU - pressure-operated units regulations (97/23/EG)  
Harmonised standards applied:  
DIN EN 60 335-1, DIN EN 60 335-2-79,  
DIN EN 55 014-1:1999, DIN EN 55 014-2:1997,  
DIN EN 61 000-3-2:1995, DIN EN 61 000-3-3:1995  
Relevant EU Directives:  
TRD 801, TRD 301, DIN 2413  
Appropriate internal measures have been taken to ensure that  
series-production units conform at all times to the  
requirements of current EU Directives and relevant standards.  
The signatories are empowered to represent and act on  
behalf of the company management.  
5.957-649 (07/01)  
Alfred Kärcher Limited Partnership.  
Registered office: Winnenden. Company Register:  
Waiblingen, HRA 169.  
Personally liable partner. Kärcher Reinigungstechnik GmbH.  
Registered office Winnenden, 2404 Waiblingen Company  
Register, HRB  
Managing directors:  
Dr. Bernhard Graf, Hartmut Jenner, Roland Kamm,  
Herbert Konhäusner, Georg Metz, Thomas Schöbinger  
Alfred Kärcher GmbH & Co.  
Cleaning Systems  
Alfred-Kärcher-Straße 28-40  
P.O.Box 160  
D-71349 Winnenden, Germany  
Phone: ++49 7195 14-0  
Fax :++49 7195 14-2212  
( Graf  
Reiser  
Schöbinger )  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Clothes Dryer IDCA G35 User Manual
Iomega Thermometer DP18 RC User Manual
JVC Speaker System CA MXJ880V User Manual
Keys Fitness Home Gym KF LP3 User Manual
KitchenAid Ice Maker KUIS15NRTB3 User Manual
KitchenAid Washer Dryer KEYE770B User Manual
Klipsch Speaker System 20M0499 User Manual
Kodak Digital Camera CX4300 User Manual
Kodak Digital Camera M381 User Manual
Kolcraft Baby Accessories S083 8 10 User Manual