Johnson Controls Weather Radio S1 TTSCC01 User Manual

USER’S INFORMATION  
MANUAL  
PREMIUM HIGH DEFINITION TOUCH  
SCREEN COMMUNICATING CONTROL  
MODELS: S1-TTSCC01  
Energy Saver  
Table of Contents  
ABOUT YOUR COMMUNICATING  
SMART RECOVERY . . . . . . . . . . . . . . . 8  
ENERGY SAVER SETTINGS . . . . . . . . 8  
USING PROGRAM SCHEDULES . . . . . 8  
TEMPERATURE OVERRIDE . . . . . . . . 13  
SCHEDULE OVERRIDE . . . . . . . . . . . . 14  
SPECIAL FEATURES . . . . . . . . . . . . . . 15  
APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . 20  
LIMITED WARRANTY . . . . . . . . . . . . . . . . 20  
CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Features . . . . . . . . . . . . . . . . . . . . . . . . . 2  
QUICK REFERENCE . . . . . . . . . . . . . . . 3  
PROGRAMMING & OPERATION . . . . . . . . 5  
DATE & TIME SETTINGS . . . . . . . . . . . 5  
SYSTEM SETTINGS . . . . . . . . . . . . . . . 6  
FAN SETTINGS . . . . . . . . . . . . . . . . . . . 6  
HUMIDITY SETTINGS . . . . . . . . . . . . . . 7  
Need Assistance?  
For assistance with this product please visit http://www.yorkupg.com  
Read and Save This Manual  
Johnson Controls Unitary Products  
542937-UUM-A-1010  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
QUICK REFERENCE  
Your new Communicating Control is preset to Non-Programmable View/Mode.  
To change the View Mode:  
1. Press Menu in the bottom right corner of your  
Settings / View Mode  
screen.  
Select a mode for the Thermostat:  
2. Press Settings icon.  
Non-  
Advanced  
Programmable  
3. Press View/Mode icon.  
Programmable  
Programmable  
4. Select Non-Programmable, Programmable or  
Advanced Programmable.  
Select a sleep screen:  
Home  
Temp Only  
Cancel  
OK  
The quick reference guide for each View/Mode is detailed in Figures 1-3.  
Current Outdoor Temperature  
(if communicating outdoor  
equipment is installed)  
Current Indoor  
Temperature  
Current  
Date & Time  
11:07AM Thu 21 Jul  
Temperature  
Setpoint  
55°  
72  
Humidity Setting  
(if display  
ON  
setting is enabled)  
71°  
Auto  
Temperature  
Adjustment  
Humidity3
0
%  
Fan Setting  
(if display setting  
is enabled)  
72°  
Alert: Change Filter  
Current Indoor  
Humidity (if display  
setting is enabled)  
Menu  
Quick  
Help  
Screen  
Lock  
System  
Popup Alerts  
Heat  
Mode  
Cool  
Mode  
Menu  
FIGURE 1: Non-Programmable Mode  
Johnson Controls Unitary Products  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
Current Outdoor Temperature  
(if communicating outdoor  
equipment is installed)  
Current Indoor  
Temperature  
Current  
Date & Time  
11:07AM Thu 21 Jul  
Program Override  
Temperature  
Setpoint  
Timer (if an override  
is active)  
55°  
74°  
Humidity Setting  
(if display  
setting is enabled)  
CANCEL  
74° to  
10:00pm  
ON  
72°  
Auto  
Temperature  
Adjustment  
Humidity
3
0
%  
Fan Setting  
(if display setting  
is enabled)  
72°  
Alert: C
ha
nge Filter  
Menu  
Current Indoor  
Humidity (if display  
setting is enabled)  
Quick  
Help  
Screen  
Lock  
System  
Popup Alerts  
Heat  
Mode  
Cool  
Mode  
Menu  
FIGURE 2: Programmable Mode  
Current Outdoor Temperature  
(if communicating outdoor  
equipment is installed)  
Current Indoor  
Temperature  
Current  
Date & Time  
11:07AM Thu 21 Jul  
Program Override  
Timer (if an override  
is active)  
Return to  
Home Screen  
62°  
Humidity Setting  
(if display  
CANCEL  
75° to  
10:00pm  
ON  
70°  
Temperature  
Override  
setting is enabled)  
Auto  
Humidity
3
0
%  
Fan Setting  
(if display setting  
is enabled)  
Schedule  
Override  
78°  
72°  
Alert: Change Filt
Menu  
Quick  
Help  
Current Indoor  
Humidity (if display  
setting is enabled)  
Screen  
Cool  
System  
Popup Alerts  
Heat  
Mode  
Menu  
Lock  
Mode  
FIGURE 3: Advanced Programmable  
4
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
PROGRAMMING & OPERATION  
DATE & TIME SETTINGS  
1. Press Menu in the bottom right corner of your  
11:07AM Thu 21 Jul  
screen.  
55°  
72°  
ON  
71°  
Auto  
Humidity30%  
72°  
Alert: Change Filter  
Menu  
2. Press Settings icon.  
Emergency  
Heat  
Fan Humidity Status Settings  
Dealer Tools Clean Schedule  
Alert: Change Filter  
Close  
3. Press Date/Time icon.  
Settings  
¿ ; ç  
Date/Time Security  
Backlight Language  
View/Mode Temp °F/°C Sound Maintenance  
OK  
4. Select Date - current month, day and year.  
Settings / Date/Time  
5. Select Clock - current hour, minutes and AM or  
Date 08 May 2009  
PM.  
Clock 12 : 00  
AM  
6. Select Clock Format (12hr or 24hr).  
7. Select Daylight Saving Time (Yes or No).  
Clock Format 12 hr 24 hr  
Observe Daylight  
Savings Time  
NOTE: 2007 and beyond, for areas that use the  
new 2007 DST calendar.  
Yes  
No  
8. Press OK when you are done.  
Cancel  
OK  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
542937-UUM-A-1010  
SYSTEM SETTINGS  
Your Communicating Control is preset to OFF mode (neither heating or cooling modes are  
selected).  
In Non-Programmable mode, Auto mode cannot be activated. If Auto mode is desired, change the  
View/Mode to either Programmable or Advanced Programmable (see page 5 for details).  
Off mode: Neither Heating or Cooling icons are  
illuminated.  
Heat mode: Heating icon is illuminated  
(red glow ring indicates heat equipment opera-  
tion).  
Cool mode: Cooling icon is illuminated  
(blue glow ring indicates cool equipment opera-  
tion).  
Auto mode: Both Heating and Cooling icons  
are illuminated (red/blue glow ring indicates  
heat/cool equipment operation).  
11:07AM Thu 21 Jul  
55°  
72°  
ON  
71°  
Auto  
Humidity3
0
%  
72°  
Alert: Change Filter  
Menu  
Emergency Heat: Emergency Heat button is  
selected via the Menu screen  
(only for heat pumps with electric heat strips).  
Emergency  
Heat  
Fan Humidity Status Settings  
Dealer Tools Clean Schedule  
Alert: Change Filter  
Close  
FAN SETTINGS  
In non-programmable mode, the fan setting defaults to the schedule currently active in the calendar.  
In programmable mode, the fan setting defaults to schedule mode.  
1. Press Menu at the bottom right side of your screen.  
NOTICE  
Or press the quick access Fan icon on the right side of your screen.  
6
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
2. Press Fan icon.  
3. Select the Fan function.  
a. Auto – runs only with equipment.  
b. Manual – runs intermittently to circulate air.  
NOTE: Manual mode is not available for all sys-  
tems.  
i. Adjust the speed of your fan motor.  
NOTE: The lower the speed the less electricity con-  
sumed.  
Emergency  
Heat  
Fan Humidity Status Settings  
Dealer Tools Clean Schedule  
Alert: Change Filter  
Close  
ii. Select the fan run time. Choices are 15,  
30, and 45 minutes per hour or Always.  
c. Schedule – follows program schedule fan  
settings (see Page 9 for more information).  
NOTE: Schedule option is only available in pro-  
grammable modes.  
Fan Adjust  
Show Fan on  
Home  
Function: Auto  
Manual Schedule  
45%  
xx%  
100%  
4. Select check box to display fan icon on home  
screen.  
Run fan  
30 minutes  
Per Hour  
Cancel  
5. Press OK when you are done.  
OK  
HUMIDITY SETTINGS  
In non-programmable mode, your Communicating Control humidity setting defaults to auto mode.  
In programmable mode, the humidity setting defaults to schedule mode.  
1. Press Menu.  
Humidity Adjust  
NOTE: Or press the quick access Humidity icon on  
the right side of your screen.  
Show Humidity  
Level on Home  
22%  
When Heating...  
Mode:  
2. Press Humidity icon.  
Function: Auto  
Manual Schedule  
Cancel  
3. Select the Humidity mode.  
a. Humidification – Select the Heat mode sym-  
bol.  
b. Dehumidification – Select the Cool mode  
symbol.  
OK  
4. Select Humidity function.  
Humidity Adjust  
a. Auto – Automatically sets the humidity set-  
point based on indoor temperature.  
Show Humidity  
Level on Home  
22%  
When Heating...  
Mode:  
NOTE: Auto mode requires an outdoor sensor.  
b. Manual – Manually set the humidity setpoint.  
Auto  
Manual Schedule  
Function:  
35%  
i. Select your desired indoor humidity  
percentage level.  
45%  
100%  
NOTE: If you start seeing condensation building up  
on your windows, lower the humidity setpoint or  
switch to auto mode.  
Cancel  
OK  
c. Schedule – Follows program schedule humidity settings (See Page 9 for more information).  
NOTE: Schedule option is only available in programmable modes.  
5. Select check box to display humidity information on home screen.  
6. Press OK when you are done.  
Johnson Controls Unitary Products  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
SMART RECOVERY  
Your Communicating Control comes with a feature called Smart Recovery, which eliminates all  
guesswork when setting your program schedule.  
How long does it take the furnace to warm your house in the morning before you get out of bed or  
how long does it take the air conditioner to cool your house in the afternoon before you return from  
work? The Communicating Control determines the equipment start time to satisfy your desired tem-  
perature setpoint.  
Simply set your program schedule to the time you want the house to be at your comfort tempera-  
ture. The Communicating Control then turns on the heating or cooling at just the right time to have  
your home reach your comfort temperature at your scheduled time.  
For example: you get out of bed at 6:00 AM and want the temperature to be 70°F. Set the Awake  
period for 6:00 AM and 70°F. The Communicating Control will turn on the heat before 6:00 AM to  
raise the temperature to 70°F by 6:00 AM.  
ENERGY SAVER SETTINGS  
Energy Saver feature allows you to program your system for maximum energy savings. You can  
chose from two, three or four time periods each day, with different settings for each day.  
This Communicating Control is preset to use Energy Saver program settings. These settings would  
help reduce your heating/cooling expenses.  
Setpoints  
Setpoints  
Fan Setting  
Heat  
Cool  
Hum  
Dehum  
Awake (6:00 AM)  
Day (8:00 AM)  
70°  
62°  
70°  
78°  
85°  
78°  
Auto  
Auto  
Auto  
Auto  
Auto  
Return (5:00 PM)  
Sleep (10:00 PM)  
62°  
82°  
Auto  
USING PROGRAM SCHEDULES  
In a Non-Programmable mode, adjusting program schedule cannot be done.  
NOTICE  
In order to edit or run a program schedule, change the View/Mode to either Programmable  
or Advanced Programmable (see page 3 for details).  
1. Press Menu.  
Schedule  
2. Press Schedule icon.  
Create or edit schedules  
New  
Edit  
Viewer  
Assign to  
Calendar  
Import/  
Export  
Copy  
Delete  
Cancel  
Save  
8
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
Program Schedule Options  
3. Press:  
a. The New, Edit or Copy icons to create a new or edit an existing schedule. Refer Page 9.  
b. The Delete icon to delete an existing schedule. Refer Page 12.  
c. The Viewer icon to view existing schedule summaries. Refer Page 12.  
d. The import/export icon to import or export a program schedule. Refer to Page 12.  
e. The Assign to Calendar icon to assign an existing schedule to the calendar. Refer Page 12.  
A. Creating New or Editing/Copying an Existing Schedule  
Name  
Step 1 - Press Edit icon.  
Schedule  
a. Use the keyboard to name the schedule.  
NAME  
DAY  
TIME  
TEMPERATURE  
FAN  
HUMIDITY  
b. Press OK.  
Please name this schedule...  
Schedule 3  
Step 2 - Press Next.  
Edit  
Cancel  
Next  
Day  
Step 3 - Select Day to set schedule.  
Step 4 - Press Next.  
Schedule  
NAME  
DAY  
TIME  
TEMPERATURE  
FAN  
HUMIDITY  
NOTE: Each program schedule is identified by a  
color. Color shades represent unique pro-  
gram schedule settings.  
Schedule 3  
Select day  
to edit:  
Default settings based on Energy Saver  
Cancel Save Quit  
Previous Next  
+
Time  
Step 5 - Select Number of Events (2, 3 or 4 events  
Schedule  
NAME  
per day).  
DAY  
TIME  
TEMPERATURE  
FAN  
HUMIDITY  
Step 6 - Select Event to set start time.  
Number  
of Events:  
Wed  
2
3
4
Step 7 - Adjust time that corresponds to the event.  
Select Event Awake  
6:00 am  
Day  
9:00 am  
Return Sleep  
6:00 pm 10:00 pm  
Step 8 - Repeat steps 6-7 to select start time for  
to edit:  
other events.  
+ 15 min  
- 15 min  
6:00 am  
Step 9 - Press Next.  
Cancel Save Quit  
+
Previous  
Next  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
542937-UUM-A-1010  
Temperature  
Schedule  
Step 10 - Select Event to edit temperature set-  
points.  
NAME  
DAY  
TIME  
TEMPERATURE  
FAN  
HUMIDITY  
Wed  
Select Event Awake  
73° 70°  
Day  
73° 70°  
Return Sleep  
73° 70°  
73° 70°  
to edit:  
Cancel Save Quit  
+
Previous Next  
Step 11 - Adjust your Heating and Cooling set-  
Schedule / Temperature Adjust  
Adjust temperatures for Return  
points.  
Step 12 - Select OK.  
65°  
50%  
100%  
85°  
Step 13 - Repeat steps 10-12 to program tempera-  
ture for other events.  
75°  
Step 14 - Press Next.  
50°  
Cancel  
OK  
Fan  
Step 15 - Select Event to edit fan settings.  
Schedule  
NAME  
DAY  
TIME  
TEMPERATURE  
FAN  
HUMIDITY  
Wed  
Select Event Awake  
Auto  
Day  
85%  
Return Sleep  
Auto  
75%  
to edit:  
Cancel  
Previous Next  
Step 16 - Select the Fan function.  
a. Auto  
b. Manual  
NOTE: Manual mode is not available for all  
systems.  
Schedule / Fan Adjust  
Awake:  
i. Adjust the speed of your fan motor.  
Function  
Auto  
Manual  
NOTE: The lower the speed the less electricity  
consumed.  
45%  
xx%  
100%  
ii. Select the fan run time. Choices are  
15, 30, and 45 minutes per hour or  
Always.  
Run fan  
Always  
Cancel  
OK  
Step 17 - Select OK.  
Step 18 - Repeat steps 15-17 to select fan mode for  
other events.  
Step 19 - Press Next.  
10  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
Humidity  
Step 20 - Select the Humidity mode.  
Schedule  
a. Humidification – select the Heat mode  
NAME  
DAY  
TIME  
TEMPERATURE  
FAN  
HUMIDITY  
symbol.  
b. Dehumidification  
mode symbol.  
Wed  
Mode:  
%RH When Heating...  
select the Cool  
Function: Auto  
Manual  
Step 21 - Select the Humidity function.  
45%  
xx%  
100%  
a. Auto – automatically sets the humidity  
setpoint based on indoor temperature.  
NOTE: Auto mode requires an outdoor sensor.  
b. Manual – manually set the humidity setpoint.  
Cancel  
Previous Next  
i. Select your desired indoor humidity percentage level.  
Step 22 - Press Next.  
NOTE: Steps 3-22 illustrate how to set a single day’s program schedule. You can copy this day to  
subsequent days (see Copy Day section below), or set another day by repeating steps 3-22.  
Copy Day  
Step 23 - Press Copy.  
Schedule  
NAME  
DAY  
TIME  
TEMPERATURE  
FAN  
HUMIDITY  
Schedule 3  
Select day  
to edit:  
We
Copy... Use Energy Saver  
Cancel Save Quit  
+
Edit  
Step 24 - Select individual days, Weekdays,  
Weekend or Everyday.  
Copy Day to...  
Select Day or Group to Apply Copied Day (We)  
Step 25 - Press OK.  
Mo Tu We Th Fr Sa Su  
Everyday  
Step 26 - Repeat steps 23-25 to copy settings to  
other days.  
Weekdays  
Weekends  
Cancel OK  
Saving a Program Schedule  
Step 27 - Select Save + Quit.  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
542937-UUM-A-1010  
B. Deleting an Existing Program Schedule  
Step 1 - Press Yes.  
Delete?  
Delete this schedule?  
No  
Yes  
C. Viewing an Existing Program Schedule  
Step 1 - Select Schedule to view by pressing left or  
Schedule Viewer  
View  
right arrows.  
Schedule 3  
(Active in Calendar)  
Step 2 - Select Day to view.  
Step 3 - Press Close.  
Mo Tu We Th Fr Sa Su  
Awake  
73° 70°  
6:00am  
Day  
73° 70°  
8:00am  
Return Sleep  
70° 65°  
5:00pm  
73° 70°  
10:00pm  
Close  
D. Importing / Exporting Program Schedules  
Step 1 - Select Import or Export functionality.  
For Import  
Step 2 - Insert the USB into the bottom of the thermostat when prompted.  
Step 3 - When prompted that import is complete, remove USB from drive.  
Step 4 - Select OK after import is complete.  
For Export  
Step  
1
-
Step 2 - Insert the USB into the bottom of the thermostat when prompted.  
Step 3 - When prompted that export is complete, remove USB from drive.  
Step 4 - Select OK after export is complete.  
E. Assigning Program Schedules to Calendar  
Step 1 - Select Schedule to assign to calendar by  
Schedule  
pressing up or down arrows.  
Select Schedule:  
Assign to Calendar  
Step 2 - Select individual months, Seasons, or All  
Winter  
Spring  
Year.  
Dec Jan Feb Mar Apr May  
June July Aug Sep Oct Nov  
Step 3 - Repeat steps 1-2 for each schedule's cal-  
endar assignment.  
Step 4 - Press Done.  
Summer  
Fall  
Done  
NOTE: In order to run a program schedule, it must  
be assigned to the calendar.  
Cancel  
12  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
TEMPERATURE OVERRIDE  
Programmable Mode  
1. Press temperature adjustment arrows either  
up or down until the desired override tempera-  
ture setpoint is shown.  
11:07AM Thu 21 Jul  
45°  
72°  
2. Press Pick Duration button.  
Auto  
Auto  
Pick  
Duration  
72°  
3. Select the duration for running the temperature  
override.  
Humidity30%  
65°  
a. Until Cancelled – holds temperature until  
cancelled.  
b. Until specific Date & Time – holds tempera-  
ture until specified date and time.  
c. Until program schedule Next Event – hold  
temperature until next schedule event.  
Menu  
Set Duration  
Hold until...  
08 : 01 PM  
Cancelled  
Next Event  
8:00 am  
Cancel  
OK  
Advanced Programmable Mode  
1. Press Thermometer icon.  
11:07AM Thu 21 Jul  
2. Use the slider to set the desired override tem-  
perature.  
Quick  
3. Press Pick Duration button.  
Pick  
Duration  
75°  
4. Select the duration for running the temperature  
override.  
70°  
50°  
85°  
a. Until Cancelled – holds temperature until  
cancelled.  
b. Until specific Date & Time – holds tempera-  
ture until specified date and time.  
Alert: Change Filter  
Menu  
Set Duration  
Hold until...  
c. Until program schedule Next Event – hold  
temperature until next schedule event.  
08 : 01 PM  
Cancelled  
Next Event  
8:00 am  
Cancel  
OK  
Quick Heat / Quick Cool  
1. Press Thermometer icon.  
2. Select Quick Heat / Quick Cool icon – runs heat/cool equipment at maximum capacity for 10  
minutes.  
Johnson Controls Unitary Products  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
SCHEDULE OVERRIDE  
Advanced Programmable Mode  
1. Press Schedule icon.  
2. Select:  
a. The current program schedule (NOW) event to extend the duration.  
b. The desired program schedule (OVERRIDE) event to override with a future event.  
c. The Set Vacation to setup a Vacation Override.  
A. Extend Current Program Schedule Event  
To extend the current program schedule event's set-  
tings (temperature, fan, and humidity) beyond the  
scheduled event time, perform the following:  
5:37PM Thu 21 Jul  
Step 1 - Select current program schedule event  
Set Vacation...  
(NOW shown in highlighted box).  
Step 2 - Press OK.  
NOW  
Extend NOW or change to...  
Step 3 - Select the duration for running the sched-  
Day  
78° 70°  
8:00am  
Sleep Awake  
82° 62°  
10:00 pm  
Day  
85° 62°  
8:00 am  
78° 70°  
6:00 am  
ule override.  
Step 4 - Until Cancelled – permanent hold.  
a. Until specific Date & Time.  
OK  
Menu  
b. Until program schedule Next Event.  
B . Change to Future Program Schedule Event  
Arrive home from work early? To initiate a future  
9:07AM Thu 21 Jul  
program schedule event's settings (temperature,  
fan, and humidity) prior to the scheduled event time,  
perform the following:  
Set Vacation...  
NOW  
OVERRIDE  
Step 1 - Select desired program schedule event  
(OVERRIDE shown in highlighted box).  
Awake  
73° 70°  
9:00am  
Day  
73° 70°  
10:00 am  
Return  
78° 64°  
6:00 pm  
Sleep  
70° 67°  
11:30 pm  
Step 2 - Press OK.  
OK  
Menu  
C. Vacation Override  
Step 1 - Select number of Days or  
Step 2 - Select Vacation Dates:  
a. Leave Date - current month, day and year.  
b. Return Date - current month, day and year.  
c. Press Next.  
Vacation  
For how long?  
Leave 08 May  
Return 10 May  
AM  
10 AM  
2009  
2009  
10  
Days  
2
Cancel  
Next  
14  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
Step 3 - Adjust your Heating and Cooling set-  
Vacation  
points.  
Set Temperatures  
50%  
Step 4 - Press Next.  
65°  
100%  
85°  
76°  
50°  
Cancel  
Vacation  
Previous  
Next  
Step 5 - Adjust your Fan setting.  
Step 6 - Press Next.  
Set Fan  
Auto  
Manual  
Function:  
Cancel  
Previous  
Next  
Step 7 - Adjust your Humidity settings.  
Step 8 - Press Done.  
Vacation  
Set Humidity  
When Heating...  
Step 9 - Press OK.  
Mode:  
Auto  
Manual  
Function:  
45%  
15%  
50%  
Cancel  
Previous Done  
SPECIAL FEATURES  
Equipment Status  
Equipment Status feature is used to help you understand your heating and cooling system better.  
Here are some of the highlights of this feature.  
Johnson Controls Unitary Products  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
Equipment Conditions  
1. Press Menu.  
Status  
Touch ICON for a detailed view  
2. Press Status icon.  
Heat Pump  
Thermostat  
ON  
Humidifier  
OFF  
ON  
UV Lamps  
ON  
EAC  
Not Installed  
Furnace  
ON  
Refresh Accessories  
Log  
Back  
Using the system map, you can determine your equipment conditions. The color GREEN means  
your equipment is performing as expected without any concerns. YELLOW, that particular piece of  
equipment requires some attention but not urgently. When equipment status is highlighted in RED, it  
needs immediate attention. Equipment marked in a GRAY color is not installed and is offered to  
maximize your comfort and indoor air quality. For more information on equipment highlighted in  
GRAY color, contact your installing dealer for more details.  
Equipment Operational State  
For detailed information on the current operational state of your heating or cooling equipment, you  
can refer to the Equipment Status screen. It displays status information about your indoor unit (air  
handler or furnace) and your outdoor unit (heat pump or air conditioner) at any given time.  
NOTICE  
Not all equipment information is shown for all systems.  
Equipment Service Reminders  
This feature displays an alert to remind you to change the air filter, humidifier pad, UV lamps or ser-  
vice your electronic air cleaner. To activate, follow these steps.  
1. Press Menu.  
Settings / Maintenance  
2. Press Settings icon.  
Cumulative Hours  
Air Filter:  
Months  
3. Press Maintenance icon.  
6 Months  
4. Air Filter, select either Cumulative Hours or  
Months. Adjust the period per the manufacturer  
recommendation.  
Humidifier Pad: Cumulative Hours Months  
15,000 Hours  
Cancel  
OK  
16  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
5. Humidifier Pad, select either Cumulative  
Hours or Months. Adjust the period per the  
manufacturer recommendation.  
Settings / Maintenance  
6. Using the bar to the right of the screen, scroll  
down to view other equipment.  
Months  
Cumulative Hours  
UV Lamps:  
6 Months  
7. UV Lamps, select either Cumulative Hours or  
Months. Adjust the period per the manufacturer  
recommendation.  
Electronic Air  
Cleaner:  
Cumulative Hours Months  
15,000 Hours  
8. Electronic Air Cleaner, select either Cumula-  
tive Hours or Months. Adjust the period per the  
manufacturer recommendation.  
Cancel  
OK  
9. Press OK when you are done.  
Expired Service Reminders  
1. Select action for expired Service reminder.  
a. Reset – reset service alert timer.  
12:32 AM Thu 9/17  
Event  
Call Your Dealer:  
b. Remind Later – specify days to notify later.  
Replace UV lamps in 1 month  
Model 1138  
Log  
Dealer  
Remind Later Reset  
A. Reset  
Reset  
Step 1 - After replacing consumable, select YES to  
Were the UV lamps replaced?  
reset the reminder timer.  
Step 2 - Press OK.  
Cancel  
Yes  
B. Remind Later  
Alert  
Step 1 - To be reminded at a later date, set duration  
of days using up and down arrows.  
Remind me again in...  
Step 2 - Press OK.  
Days 08  
Cancel  
OK  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
542937-UUM-A-1010  
Trilingual Communicating Control  
Your Communicating Control’s language is preset to English. It comes equipped with 2 other lan-  
guages to choose from. To switch to a different language, follow these steps.  
1. Press Menu.  
Settings / Language  
2. Press Settings icon.  
English  
Español  
Français  
Language  
3. Press Language icon.  
4. Make your language selection.  
5. Press OK.  
Cancel  
OK  
Temperature Format  
Your Communicating Control’s temperature format is preset to Fahrenheit. To switch to Celsius tem-  
perature format, follow these steps.  
1. Press Menu.  
Settings / Temperature  
Temperature °F/°C  
2. Press Settings icon.  
3. Press Temp F/C icon.  
4. Make your temperature format selection.  
5. Press OK.  
Fahrenheit  
Celsius  
Cancel  
Done  
Dealer Contact Information  
Your installer dealer/contractor contact information can be stored in your Communicating Control.  
To view your dealer/contractor contact information, follow these steps.  
1. Press Menu.  
2. Press Dealer icon.  
18  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
542937-UUM-A-1010  
Screen Lock  
To prevent tampering with your Communicating  
Control, the screen can be fully locked. To activate  
the screen security setting, follow these steps:  
Emergency  
Heat  
Fan Humidity Status Settings  
Dealer Tools Clean Schedule  
Alert: Change Filter  
Close  
1. Press Screen Lock button on the Home screen  
or  
Settings  
2. Press Menu, Press Settings icon, and Press  
Security icon.  
¿ ; ç  
Date/Time Security  
Backlight Language  
View/Mode Temp °F/°C Sound Maintenance  
OK  
3. Press ON icon to activate screen lock settings.  
4. Press OK.  
Settings / Security  
OFF  
ON  
Change PIN  
Security  
a. You will be prompted to enter your new PIN  
number if you have not already done so.  
Cancel  
OK  
5. Press OK.  
Locked  
Your screen security is now activated. Make sure  
you remember your pin number.  
1
2
3
6
9
0
Please enter PIN  
4
7
5
8
8888  
Bksp  
Cancel  
OK  
Johnson Controls Unitary Products  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
Screen Cleaning  
1. Press Menu.  
Emergency  
Heat  
Fan Humidity Status Settings  
Dealer Tools Clean Schedule  
Alert: Change Filter  
Close  
2. Press Clean icon to lock the screen for cleaning.  
The screen will remain locked for 15 seconds to  
allow you to clean the screen without changing  
any settings. After 15 seconds, normal screen  
operation will resume. If more time is needed for  
cleaning, repeat steps 1 and 2 above.  
TOUCH SCREEN DISABLED  
OK to clean screen now.  
:15  
Press and Hold to Exit  
NOTICE  
Do not spray any liquid directly on the thermostat. Spray liquids onto a cloth, and then use  
the damp cloth to clean the screen. Use water or household glass cleaner. Do not use  
abrasive cleansers.  
APPENDIX  
Frequently Asked Questions and Answers.  
Q: Next to Fan on the Home screen, Auto or On is shown. What does this mean?  
A: The Fan is set for Auto (to run with equipment) or On (to circulate air in your home). See “Fan  
Settings” on page 9 for more information.  
Q: Why doesn’t the Communicating Control respond when I touch the keys?  
A: Check to determine if the screen is in the Locked or Clean mode. See “Screen Lock” on page 28  
or “Screen Cleaning” on page 29.  
Subject to change without notice. Published in U.S.A.  
Copyright © 2010 by Johnson Controls, Inc. All rights reserved.  
542937-UUM-A-1010  
Supersedes: Nothing  
Johnson Controls Unitary Products  
5005 York Drive  
Norman, OK 73069  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Insignia Marine Instruments NS MB5200B User Manual
Insignia Network Card NS PU98505 User Manual
JAMO Portable Speaker Rock 63 A User Manual
JL Audio Speaker MX10IB3 User Manual
JVC Flat Panel Television AV 32R370KE User Manual
JVC Stove LP20878 001 User Manual
Kalorik Blender USK BL 6 User Manual
Kambrook Air Conditioner KRH110 User Manual
Kambrook Fan KFH15 User Manual
Kenmore Vacuum Cleaner 11630912 User Manual