John Mills Plumbing Product BS7291 User Manual

CI/SfB  
53.0  
Ih6  
John Guest Speedfit Limited  
Horton Road, West Drayton, Middlesex UB7 8JL, England.  
Technical Help Desk: 01895 425333  
THE PUSH-FIT SOLUTION FOR  
PLUMBING & HEATING SYSTEMS  
No.’s 95/3177  
BS7291  
KM39767  
The company has a policy of continuous research  
and development and reserves the right to amend  
without notice the specification and design of all  
products illustrated in this catalogue. John Guest  
AVAILABLE FROM:  
UK PRODUCT RANGE AND  
Speedfit reserve the right to change the colour and  
shape of products. Photographs are for illustration  
purposes only.  
Subject to our Terms and Conditions  
of Sale available on request.  
INSTALLATION GUIDE  
,
and  
are registered  
trademarks of John Guest International Limited  
© Copyright 2007.  
October 2007  
Z2105/217/10/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM FEATURES  
WORKING TEMPERATURES AND PRESSURES  
All white system  
Application  
Usual Working  
temperature, ºC  
Maximum working  
temperature, ºC  
Maximum working  
pressure, bar  
Truly demountable without damage to pipe or fitting  
Grip and seal connection  
Cold Water  
20  
20  
12  
(indirect and direct mains)  
Contents  
Central Heating  
82  
65  
105, short term  
malfunction at 114  
95  
3
Superseal Insert gives secondary seal  
Reduced pipe insertion force  
Lightweight and easy to handle on site  
Hot Water  
6
PLUMBING AND HEATING  
(including unvented cylinders)  
Speedfit fittings suitable for central heating systems can  
withstand temperatures up to 114°C intermittently for  
short periods.  
Plumbing and  
09 - 10  
11 - 12  
SYSTEM BENEFITS  
Heating Fittings  
Installation time reduced by up to 40%  
Speedfit fittings shown as not suitable for central heating  
systems are used primarily on the domestic hot and cold  
water system accepting temperatures of up to 65°C.  
Pipe flexibility permits the cabling of pipe through less  
accessible areas  
Flexi Hoses  
No risk of fire or flames from a blowtorch  
Easier to work in confined places  
A permanent leak-proof connection  
Corrosion free  
Brass Fittings  
Valves  
12  
13  
HANDLING FITTINGS AND PIPE  
Ensure fittings and pipe are kept clean at all times by  
keeping them in bags and boxes provided.  
No scale build up  
Lower thermal diffusivity maintains safer surface  
temperature  
Do not empty Speedfit Products onto the floor area.  
Pipe elasticity can reduce the possibility of bursting  
under freezing conditions  
Ensure internal ‘O’ Ring seals are kept free from dirt and debris.  
Pipe and  
Accessories  
14 - 15  
Lead free and non toxic  
Less noise from water flow and expansion/contraction  
Long pipe lengths reduce fittings required  
PRODUCT SELECTION AND INSTALLATION  
John Guest fittings and related products are specifically  
designed and manufactured by John Guest to the  
Technical Specifications set out in the John Guest  
Product Catalogues. All John Guest fittings and related  
products should be selected, installed, used and  
maintained in accordance with these Technical  
Specifications. It is the customer’s / user’s responsibility  
to ensure that John Guest fittings and related products  
are suitable for their intended applications, are properly  
installed and maintained and are used in accordance with  
the Technical Specifications. It is also the customer’s /  
user’s responsibility to provide it’s own customers with  
any relevant technical information about John Guest  
products it supplies them.  
UNDERFLOOR HEATING  
GUARANTEE  
As a result of long term test programmes and rigorous  
quality standards, John Guest Speedfit Limited offer a 25  
year guarantee against the defects in materials or  
manufacturing of ‘PEM’, ‘PSE’ and ‘SFM’ Range  
Plumbing Fittings and Speedfit Barrier Pipe  
manufactured by John Guest.  
Designed to be quick and easy to install.  
22 - 26  
John Guest Underfloor Heating Products, which should  
be installed and maintained in accordance with our  
recommendations, carry a 2 year guarantee against  
defects in materials and manufacture.  
UNDERGROUND FITTINGS  
John Guest Plumbing and Heating Products are for use  
with normal UK domestic plumbing and heating systems  
and supplied in accordance with our Conditions of Sale.  
For connecting MDPE  
Cold Water Service Pipe.  
27 - 28  
Speedfit should not be used for gas, fuel oil or compressed  
air applications.  
SPECIAL APPLICATIONS  
John Guest produce a push fit system of pipe and fittings for  
compressed air situations. See seperate literature for details.  
Boats. The flexibility of the Speedfit System ensures it can  
be cabled easily around the interior and hidden from view.  
Caravans. Speedfit is ideal for caravan installations due  
to its flexibility and its resistance to corrosion and freezing.  
TECHNICAL CHECKLISTS  
Plumbing and Heating  
Exhibitions. The unique ability of the Speedfit System to  
be easily demounted and reused, together with its  
flexibility, makes Speedfit ideal for this application.  
29  
Agricultural and Horticultural. Speedfit has many  
applications in agricultural and horticultural environments.  
Portable Buildings (site cabins, toilets). As with caravans,  
Speedfit is well suited to this application.  
Underfloor Heating  
30  
30  
Underground Fittings  
03  
04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STANDARD SPEEDFIT FITTINGS  
MAKING A GOOD CONNECTION  
Push pipe up to stop  
PREPARE THE PIPE  
Fittings and pipe should be kept clean bagged and undamaged  
before use.  
HOW SPEEDFIT WORKS  
Pipe mark indicates  
full insertion.  
Secondary Seal  
Ensure the pipe is free of score  
marks. Cut the pipe square.  
When using Speedfit Barrier Pipe  
cut along an insertion mark. We  
Speedfit Fittings have a unique grip then seal construction made up of a collet with stainless  
steel teeth to grip the pipe and an ‘O’ ring to provide a permanent leak proof seal.  
Standard Speedfit connections are made in the same way  
as Twist and Lock.  
Use of the Superseal Pipe Insert ensures a double ‘O’ ring seal.  
recommend the use of JG Pipe  
Cutters.  
Pipe Cutter  
JG TS  
Push Pipe up to Pipe Stop. If the Speedfit Pipe has been  
cut correctly the insertion mark on the pipe will be level  
with the collet head.  
An ‘O’ ring at the head of the insert and the shape of the stem, provide a secondary seal against  
the bore of the fitting. A combination of this and the main ‘O’ ring ensure a good connection.  
Speedfit  
Barrier Pipe  
The stem of the insert gives greater rigidity of the length of pipe within the fitting, reducing the  
chance of leaks if a side load is applied.  
To prevent damage to the ‘O’ ring  
remove all burrs and sharp edges.  
When connecting Speedfit Pipe  
use a Superseal Pipe Insert. A  
twisting motion will aid insertion.  
The insert should only be used  
with Speedfit Pipe.  
Pull to check connection  
is secure and test the  
system. Our recommended  
test procedure is shown  
in our Technical Checklist  
on page 29.  
The head of the insert has been designed for ease of insertion.  
The additional benefit of Twist and Lock Fittings is that a twist of a screwcap locks the pipe in  
position and gives increased compression on the ‘O’ ring for even greater security.  
TO DISCONNECT  
NEW TWIST AND LOCK FITTINGS  
Ensure that the system  
is depressurised.  
Gap between Cap  
and Flange  
Grips before it seals  
The screwcap on Twist  
and Lock Fittings will  
need to be turned back  
to the unlocked position.  
Pipe mark indicates  
full insertion  
Push the collet square against the face of the fitting by  
using fingers or with the help of our collet release tool.  
The fitting should be in the ‘unlocked’ position, this is  
shown with a small gap between the screwcap and the  
body flange.  
With the collet held in position the pipe can be removed.  
Stainless steel teeth  
grip the pipe  
The fitting can be used again without the need for  
replacement parts.  
Push the pipe fully into the fitting, up to the pipe stop. If  
the Speedfit Pipe has been cut correctly the insertion  
mark on the pipe will be level with the collet head. The ‘O’  
ring on the Superseal Pipe Insert provides a secondary  
seal against the bore of the fitting. A good connection  
has been made.  
WHAT NOT TO DO  
Don’t use hacksaws to cut the  
pipe or leave burrs on the end of  
the pipe.  
If you are not using collet  
clips, ensure that the  
screwcaps are in the  
locked position.  
Don’t use  
damaged or  
scored pipe.  
Pull to check it is secure. It is good practice to test the system  
prior to leaving the site or before use. Our recommended  
test procedure is shown in our Technical Checklist.  
Pipe insert gives  
secondary seal  
Main ʻOʼ Ring Seal  
ADDED BENEFIT TWIST AND LOCK  
Twist the screwcap until it  
touches the body flange.  
This increases the ‘O’ ring  
seal around the pipe and  
locks the pipe into position.  
Don’t forget to push the  
pipe fully into the fitting,  
past both the collet (gripper)  
and the ‘O’ ring.  
Fitting may be gripped but not  
sealed if pipe is not fully inserted.  
Do not insert fingers into the fitting as the stainless steel  
teeth may cause injury.  
Remember to pressure test the completed installation  
according to the recommendations in our Technical Checklist.  
05  
06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TAP CONNECTORS  
STOP END  
SPEEDFIT MANIFOLD  
The unique feature of the  
Speedfit Concept, the ability  
to disconnect the fitting  
should you want to, means  
the Speedfit Stop End not  
only provides a permanent  
leakproof seal, but can be  
readily removed to allow  
work to restart or to allow  
an extension to a system.  
Thus, the fitting is especially  
useful to allow water to be  
turned back on, overnight for  
instance, or if a job has to be  
interrupted for another reason.  
Speedfit manufacturer a wide range of connectors  
including conventional straight and bent tap connectors.  
Speedfit have introduced an innovative 22mm x 10mm 4  
way manifold. Departing from the usual manifold design,  
this new product has 4 in-line 10mm outlets, offering a  
neater envelope size and therefore a much smaller  
installation space.  
PIPE STOP DISTANCES  
Stops are located at the following distances from the end  
of the fitting:  
Other benefits include better flow characteristics and a  
more even distribution of hot water.  
size  
10mm  
20mm  
15mm  
30mm  
22mm  
35mm  
28mm  
44mm  
stop distance  
The 22mm and 10mm Speedfit push-fit connections make  
for a fast and easy installation, even in confined spaces.  
The range also offers a special and  
unique Tap Connector that only  
requires a simple hand tightening to  
connect up a terminal tap, mixer or  
float valve. An integral seal within the  
fitting avoids the need for further  
sealant. The connectors are useful  
when replacing existing brassware or  
in other confined spaces.  
Stop end  
Whilst designed as a heating product, the manifold can  
also be used in a mains pressure hot or cold domestic  
plumbing system, to feed bathroom or kitchen taps and  
mixers. This allows for a more efficient installation as  
every terminal fitting has its own dedicated supply.  
Stop ends are also useful when pressure testing a system  
before appliances are connected.  
COLLET COVERS  
STEM ELBOW  
Coupling up to a supply is easy. The  
pipe is simply pushed home into  
the Speedfit connection and is  
instantly secured, without the need  
for specialist tools.  
Use a collet cover or collet clip to provide added security  
against pipe disconnection, e.g. the fitting coming into  
contact with rigid surfaces and behind dry-lining walls.  
Designed to simplify pipe connection  
in restricted spaces. The Speedfit  
Stem Elbow provides an instant swivel  
fitting so pipe can be orientated in  
any direction.  
Collet covers for use with standard Speedfit fittings, are  
available in white or in red or blue to allow colour coding of pipes.  
APPLIANCE TAP  
A special 10mm version gives a neat  
connection from concealed plumbing to  
a radiator.  
Collet cover  
The Speedfit range includes an Appliance Tap for  
the permanent connection of washing machines and  
dishwashers, thus enabling complete water isolation to  
the appliance.  
FLEXI HOSES  
COLLET CLIPS  
Collet clip  
SERVICE VALVE  
Manufactured to a quality you would expect from Speedfit,  
our range of Flexi Hoses has 40 different patterns.  
The Speedfit range of brass  
chromium plated service  
valves can be used on both  
hot and cold water services  
and central heating. Push fit  
connections mean much  
reduced installation time,  
especially in confined spaces.  
A simple push fit connection of the supply pipe and a  
plastic thread on the outlet to marry well with the plastic  
thread on the hose means the Speedfit Appliance Tap is very  
easy to install. The large round handle is easy to grip and turn.  
Available in lengths from 150mm to 1,000mm, ends are  
either push fit to union nut or push fit to push fit, including  
hoses with an integral service valve operated by a 1/4 turn  
screwdriver slot.  
Collet clips are available in grey and white for use with  
standard fittings to prevent accidental pipe  
disconnection.  
SUPERSEAL PIPE INSERT  
Apart from being aesthetically pleasing the new white  
hoses offer more flexibility and a larger through bore  
for better flow characteristics.  
The Superseal Pipe Insert has been developed to be used  
with Speedfit Barrier Pipe and Speedfit Fittings to provide  
an extra line of defence when installing a Speedfit Push  
Fit System.  
Red or blue collet clips provide colour coding of pipe on  
twist and lock fittings.  
The valves, in 10 to 22mm,  
have a 1/4 turn open/close  
mechanism operated by a  
screwdriver slot or a lever.  
They are not designed to prevent accidental release and  
should be fitted when the fitting is in the locked position.  
The insert has it’s own ‘O’ ring which, with a stem sliding  
within the inside of the pipe, gives a secondary seal  
against the inside of the fitting.  
Tap connector patterns have  
a union nut to connect  
direct to a tap or floatvalve.  
Lever operated valves are  
supplied with both a blue  
and a red indice.  
More specialist patterns  
have been designed to help  
the installation of monobloc  
mixers to a 15mm supply.  
Sold in pairs, each hose in  
the pair has a different  
spanner location to ease  
connection of the threaded  
end into the monobloc’s  
inlets.  
The ability of Speedfit products  
to twist whilst in situ  
allows the screwdriver slot  
operating valve to be turned  
out of sight, helping to avoid  
unauthorised tampering.  
RELEASE AID  
The Speedfit Connection, when made with the insert, has  
a number of design features.  
The action of pressure in a system could increase the grip  
of the collet. The release aid allows a firmer grip on the  
collet whilst removing the pipe.  
Sliding the stem of the insert into the pipe gives greater  
compression of the main ‘O’ ring on the pipe and greater  
rigidity of the length of pipe within the fitting, reducing the  
chance of leaks if a side load is applied.  
Release aid  
Speedfit x Speedfit  
A connection is easier to make because the head of the  
insert has been designed for ease of insertion.  
Mechanism twists out of sight  
The hoses are suitable for cold water up to 10 Bar and  
hot water (65˚C max) up to 6 Bar and approved by WRAS.  
07  
08  
Superseal Inserts are listed on page 14.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLUG  
EQUAL TEE  
FEMALE COUPLER - TAP CONNECTOR  
PART NO.  
SIZE MM  
PART NO.  
SIZE  
PART NO.  
SIZE MM  
PSE3210W  
PSE3201W  
PSE3203W  
PSE3202W  
10mm x 1/2” BSP  
15mm x 1/2” BSP  
15mm x 3/4” BSP  
22mm x 3/4” BSP  
PL10  
PL15  
PL22  
PL28  
10  
15  
22  
28  
PEM0210W  
PEM0215W  
PEM0222W  
PEM0228W  
10  
15  
22  
28  
PLUMBING FITTINGS  
Suitable for central heating systems  
Suitable for central heating systems.  
Suitable for central heating systems.  
Note: Plastic threads are not as strong  
Requires hand tightening only.  
as metal threads.  
For torque figures see Technical Checklist.  
EQUAL STRAIGHT CONNECTOR  
PLASTIC BACK PLATE ELBOW  
PART NO.  
SIZE MM  
REDUCING TEE  
STRAIGHT TAP CONNECTOR  
PART NO.  
SIZE  
PEM0410W  
PEM0415W  
PEM0422W  
PEM0428W  
10  
15  
22  
28  
MM  
X
BSP  
PART NO.  
SIZE MM  
PART NO.  
SIZE  
PEM3015BW  
PEM3015AW  
PEM3022CW  
PEM3022BW  
PEM3022DW  
PEM302210AW  
PEM3022AW  
PEM3028BW  
PEM302815AW  
PEM3028AW  
PEM3028DW  
15 x 10 x 10  
15 x 15 x 10  
15 x 15 x 22  
22 x 15 x 15  
22 x 15 x 22  
22 x 22 x 10  
22 x 22 x 15  
28 x 22 x 22  
28 x 22 x 28  
28 x 28 x 15  
28 x 28 x 22  
15PWB  
15 x 1/2"  
PEMSTC1514  
PEMSTC1516  
PEMSTC2216  
15mm x 1/2” BSP  
15mm x 3/4” BSP  
22mm x 3/4” BSP  
Hot and cold water only, maximum 65  
ºc.  
Protect from sunlight and frost.  
Suitable for central heating systems.  
Suitable for central heating systems.  
With brass swivel nut and sealing washer.  
For torque figures see Technical Checklist.  
Sizes are listed in the following order.  
MANIFOLDS  
1
2
REDUCING STRAIGHT COUPLER  
4 WAY MANIFOLD  
PART NO.  
SIZE MM  
BENT TAP CONNECTOR  
3
PART NO.  
SIZE MM  
PEM201510W  
PEM202215W  
15 x 10  
22 x 15  
PART NO.  
SIZE  
SFM512210S  
22 x 10  
Suitable for central heating systems.  
PEMBTC1514  
15mm x 1/2” BSP  
Suitable for central heating systems.  
Suitable for central heating systems.  
Suitable for central heating systems.  
For torque figures see Technical Checklist.  
STEM TEE  
PART NO.  
SIZE MM  
PEM532210W  
PEM532215W  
22 x 22 x 10  
22 x 22 x 15  
With brass swivel nut and sealing washer.  
PE-COPPER COUPLER  
Suitable for central heating systems.  
PART NO.  
SIZE MM  
JG601B  
20 x 15  
25 x 15  
25 x 22  
4 PORT RAIL MANIFOLD  
CONVERSION CONNECTOR  
JG603B  
Sizes are listed in the following order.  
PART NO.  
SIZE  
PART NO.  
SIZE MM  
JG602B  
1
2
Used to connect PE Pipe to Speedfit  
or to Table X or Y Copper.  
NC471  
NC2324  
1/2 id x 15mm  
3/4 id x 22mm  
Cold water only.  
SFM522210S  
SFM522215S  
22 x 10  
22 x 15  
Taken from the Speedfit Underground Fittings  
Range, see separate section for details and  
Technical Specification.  
3
Suitable for central heating systems.  
Suitable for central heating systems.  
Connects imperial to metric pipe.  
TANK CONNECTOR  
PART NO.  
SIZE MM  
CM0715S  
CM0722S  
CM0728S  
15  
22  
28  
EQUAL ELBOW  
SLIP CONNECTOR  
PART NO.  
SIZE MM  
BRASS RAIL MANIFOLD  
PART NO.  
SIZE MM  
PEM0310W  
PEM0315W  
PEM0322W  
PEM0328W  
10  
15  
22  
28  
Suitable for cold water tanks only.  
PART NO.  
SIZE  
MM  
CM-SC-15S  
15  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
Requires hand tightening only.  
JGRAIL4  
JGRAIL6  
4 Zone  
6 Zone  
22 x 15  
22 x 15  
Maximum wall thickness of tank 4mm.  
JGRAIL12 12 Zone 22 x 15  
Suitable for central heating systems.  
STOP END  
HOSE CONNECTOR  
BRASS MANIFOLD  
PART NO.  
SIZE MM  
PSE4610W  
PSE4615W  
PSE4622W  
10  
15  
22  
PART NO.  
SIZE  
PART NO.  
SIZE  
MM  
STEM ELBOW  
NC448  
NC473  
NC737  
15mm x 1/2"  
22mm x 3/4"  
22mm x 1/2"  
PART NO.  
PIPE  
STEM  
JGMAN2-R 2 Port 3/4” x 15  
JGMAN3-R 3 Port 3/4” x 15  
JGMAN4-R 4 Port 3/4” x 15  
Suitable for central heating systems.  
PEM221010W  
PEM221015W  
PEM221515W  
PEM222222W  
10  
10  
15  
22  
x
x
x
x
10  
15  
15  
22  
Red Handle  
Blue Handle  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
JGMAN2-B 2 Port 3/4” x 15  
JGMAN3-B 3 Port 3/4” x 15  
JGMAN4-B 4 Port 3/4” x 15  
Suitable for central heating systems  
REDUCER  
Control knobs have the means to be labelled  
ʻBasinʼ, ʻBathʼ, ʻSinkʼ, ʻShowerʼ, ʻToiletʼ, ʻBidetʼ  
or ʻWashing Machineʼ.  
RADIATOR OUTLET PLATE  
Provides a swivel  
type connection.  
Please note a Collet Cover cannot be used  
on a Speedfit end assembled with the stem  
of a 22mm Stem Elbow.  
PART NO.  
SIZE MM  
Blanking plug supplied  
with each manifold.  
PART NO.  
PEM061510W  
PEM062215W  
PEM062815W  
PEM062822W  
15 x 10  
22 x 15  
28 x 15  
28 x 22  
JG- ROP  
Creates a neat outlet for 10mm supply pipes to a radiator. To be  
used with single gang 25mm steel K0 boxes to BS 4662, fitted  
with rubber grommet.  
Suitable for central heating systems.  
09  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WHITE PVC FLEXI HOSES  
BRASS FITTINGS  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C max.  
BRASS MALE COUPLER  
PART NO.  
SIZE  
MM BSPT  
X
SPEEDFIT X UNION NUT  
MW011504N BRASS  
MW012206N BRASS  
MW012808N  
15 x 1/2”  
22 x 3/4”  
28 x 1”  
SPEEDFIT X UNION NUT WITH SERVICE VALVE  
BRAIDED FLEXI HOSES  
PART NO.  
SIZE  
PART NO.  
SIZE  
MM  
X
BSP  
MM  
X
BSP  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C max.  
PART NO.  
SIZE  
300mm long  
WFLX15  
15 x 1/2”  
15 x 3/4”  
22 x 3/4”  
MM  
X
BSP  
BRASS VALVE  
FLX24P  
WFLX16  
WFLX22  
300mm long  
500mm long  
15 x 1/2”  
22 x 3/4”  
10MC (1/2) BRASS  
15MC (1/2) BRASS  
22MC (3/4) BRASS  
MW012818N  
10 x 1/2”  
15 x 1/2”  
22 x 3/4”  
28 x 1”  
FLX25P Full Bore  
500mm long  
WFLX18  
15 x 1/2”  
15 x 3/4”  
22 x 3/4”  
SPEEDFIT X UNION NUT  
FLX31P  
15 x 1/2”  
15 x 3/4”  
22 x 3/4”  
WFLX20  
WFLX19  
FLX38P  
PART NO.  
SIZE  
Suitable for central heating systems.  
Manufactured in DZR Brass.  
MM  
X
BSP  
FLX32P Full Bore  
150mm long FLX43P  
15 x 1/2"  
PLASTIC VALVE  
FLX37P  
SPEEDFIT X SPEEDFIT  
15 x 1/2”  
22 x 3/4”  
300mm long  
FLX34P  
10 x 1/2"  
15 x 3/8"  
15 x 1/2"  
15 x 3/4"  
22 x 3/4"  
PART NO.  
SIZE MM  
FLX39P  
FLX35P  
FLX15P  
FLX16P  
FLX22P  
BRASS BACK PLATE ELBOW  
300mm long  
WFLX17  
15 x 15  
PART NO.  
SIZE  
PLASTIC VALVE WITH HANDLE  
MM  
X
BSP  
FLX37-H  
FLX39-H  
15 x 1/2”  
22 x 3/4”  
15WB  
22WB  
15 x 1/2"  
22 x 3/4"  
500mm long  
FLX18P  
15 x 1/2"  
15 x 3/4"  
22 x 3/4"  
SPEEDFIT X PLAIN STEM  
FLX20P  
FLX19P  
Manufactured in DZR Brass.  
PART NO.  
PIPE  
STEM  
Suitable for central heating systems.  
SHORT VERSION  
200mm long  
WFLX51  
15  
15  
FLX23 Full Bore  
22 x 3/4"  
15WB2  
15 x 1/2"  
1000mm long FLX40  
FLX42  
15 x 1/2"  
15 x 3/4"  
22 x 3/4"  
Manufactured in Brass.  
Suitable for central heating systems.  
FLX41  
SPEEDFIT X SPEEDFIT WITH SERVICE VALVE  
ELBOW PATTERN  
BRASS MALE STEM ADAPTOR  
PART NO.  
SIZE MM  
PART NO.  
SIZE  
MM BSPT  
PART NO.  
SIZE  
X
MM  
X
BSP  
BRASS VALVE  
FLX44P  
MW051504N  
MW052206N  
MW052818N  
15 x 1/2”  
22 x 3/4”  
300mm long WFLX36  
15 x 1/2”  
300mm long  
500mm long  
SPEEDFIT X SPEEDFIT  
15 x 15  
15 x 15  
PART NO.  
SIZE MM  
FLX45P  
28 x 1” BSP  
Converts Speedfit to male thread.  
300mm long  
SPEEDFIT X UNION NUT WITH SERVICE VALVE  
FLX33P  
15 x 10  
15 x 15  
22 x 22  
Suitable for central heating systems.  
Manufactured in DZR Brass.  
FLX17P  
FLX26P  
PART NO.  
SIZE  
MM BSP  
X
PLASTIC VALVE WITH HANDLE  
500mm long  
FLX21P  
15 x 15  
22 x 22  
300mm long  
WFLX37-H  
WFLX39-H  
15 x 1/2”  
FLX27P  
BRASS FEMALE STEM ADAPTOR  
22 x 3/4”  
1000mm long  
FLX47  
15 x 15  
PART NO.  
SIZE  
MM  
X
BSP  
FOR MONOBLOC MIXERS  
MW501514N  
MW502216N  
15 x 1/2”  
22 x 3/4”  
PART NO.  
SIZE  
MM  
X
MALE  
SPEEDFIT X PLAIN STEM  
300mm long  
WFLX28  
WFLX29  
15 x M10  
15 x M12  
Suitable for central heating systems.  
Manufactured in DZR Brass.  
SPEEDFIT X MALE THREAD  
PART NO.  
PIPE  
STEM  
Converts Speedfit to female thread.  
300mm long  
FLX53  
15  
15  
PART NO.  
SIZE  
MM  
X
BSP  
BRASS MALE CYLINDER ADAPTOR  
300mm long  
FLX49  
15 x 3/8”  
IDENTITY DISCS  
PART NO.  
SIZE  
MM  
X
BSP  
PART NO.  
PACK QTY  
22CMA  
22 x 1  
FLX - RED  
FLX - BLU  
10  
10  
Suitable for central heating systems.  
Manufactured in DZR Brass.  
For handles on service valves.  
BRASS FEMALE CYLINDER ADAPTOR  
ELBOW PATTERN  
FOR MONOBLOC MIXERS  
PART NO.  
SIZE  
MM  
X
BSP  
PART NO.  
SIZE  
PART NO.  
SIZE  
MALE  
MM  
X
BSP  
MM  
X
22CFA  
22 x 1  
300mm long  
FLX36P  
15 x 1/2”  
300mm long FLX48  
12 x M10  
15 x M10  
15 x M12  
Suitable for central heating systems.  
Manufactured in DZR Brass.  
FLX28  
FLX29  
11  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONDUIT PIPE  
PIPE AND PIPE ACCESSORIES  
PLASTIC SERVICE VALVE WITH TAP CONNECTOR  
PART NO.  
SIZE  
BLACK  
PEX BARRIER PIPE  
PART NO.  
SIZE  
15BLK CON-25C  
15BLK CON-50C  
22BLK CON-25C  
22BLK CON-50C  
15mm x 25m  
15mm x 50m  
22mm x 25m  
22mm x 50m  
15SVSTC  
15 x 1/2”  
PART NO.  
SIZE  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
10BPEX-25C  
10BPEX-50C  
10mm x 25m  
10mm x 50m  
VALVES  
STOP VALVE  
Grey  
10BPEX-100C  
15BPEX-25C  
15BPEX-50C  
15BPEX-100C  
15BPEX-120C  
15BPEX-150C  
22BPEX-25C  
22BPEX-50C  
10mm x 100m  
15mm x 25m  
15mm x 50m  
15mm x 100m  
15mm x 120m  
15mm x 150m  
22mm x 25m  
22mm x 50m  
RED  
PART NO.  
SIZE  
PART NO.  
15STV  
22STV  
SIZE MM  
15  
Coils  
15RED CON-50C  
22RED CON-50C  
15mm x 50m  
22mm x 50m  
15SVSTC-W  
15 x 1/2”  
The pipe has an inner barrier to  
stop the ingress of atmosphere.  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
22  
BLUE  
White  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
British Gas accepted for water  
pipe in vented and sealed central  
heating systems.  
15BLU CON-50C  
22BLU CON-50C  
15mm x 50m  
22mm x 50m  
To be used when Speedfit Pipe is laid  
in Concrete and Masonry, see section  
on page 20.  
PLASTIC ANGLE SERVICE VALVE  
WITH TAP CONNECTOR  
Suitable for central heating systems.  
PART NO.  
SIZE  
15SVBTC  
15 x 1/2”  
PIPE IN PIPE  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
BRASS STOP TAP  
Grey  
PART NO.  
SIZE  
PART NO.  
SIZE MM  
PEX BARRIER PIPE  
15PIP-50C-E  
22PIP-50C-E  
15mm x 50m  
22mm x 50m  
15BSC  
15  
PART NO.  
SIZE  
PART NO.  
SIZE  
Only suitable for central heating.  
15BPEX-20x2L  
15BPEX-20x3L  
15BPEX-20x6L  
22BPEX-20x2L  
22BPEX-20x3L  
22BPEX-20x6L  
28BPEX-10x3L  
28BPEX-10x6L  
15mm x 2m  
15mm x 3m  
15mm x 6m  
22mm x 2m  
22mm x 3m  
22mm x 6m  
28mm x 3m  
28mm x 6m  
15SVBTC-W  
15 x 1/2”  
Head and Body manufactured in DZR Brass.  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
White  
Straight lengths  
CONDUIT ELBOW  
The pipe has an inner barrier to  
stop the ingress of atmosphere.  
BRASS SERVICE VALVE  
PART NO.  
SIZE  
WASHING MACHINE TAP  
*
PART NO.  
SIZE MM  
*By special order only.  
Suitable for central heating systems.  
CONELB  
FITS 10, 15 & 22mm  
15HSV-BRASS  
15  
PART NO.  
SIZE  
Suitable for central heating systems.  
15 APT  
15mm x 3/4" BSP  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
For torque figures on plastic threads  
please see Technical Checklist.  
BRASS CHROME PLATED SERVICE VALVE  
POLYBUTYLENE BARRIER PIPE  
PART NO.  
SIZE MM  
COLLET COVER  
PART NO.  
SIZE  
10HSV  
15HSV  
22HSV  
10  
15  
22  
PART NO.  
SIZE MM  
15BPB-25C  
15mm x 25m  
15mm x 50m  
15mm x 100m  
15mm x 120m  
15mm x 150m  
22mm x 25m  
22mm x 50m  
EMERGENCY SHUT OFF TAP  
15BPB-50C  
15BPB-100C  
15BPB-120C  
15BPB-150C  
22BPB-25C  
22BPB-50C  
PKM1910W  
PKM1910R  
PKM1910B  
AM1915W  
PM1915R  
PM1915B  
AM1922W  
PM1922R  
PM1922B  
10  
10  
10  
15  
15  
15  
22  
22  
22  
PART NO.  
SIZE MM  
Suitable for central heating systems.  
15 ESOT  
15  
Coils  
Available in white, red or blue  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
The pipe has an inner barrier to  
stop the ingress of atmosphere.  
BRASS CHROME PLATED SERVICE VALVE  
WITH TAP CONNECTOR  
Suitable for central heating systems.  
British Gas accepted for water  
pipe in vented and sealed central  
heating systems.  
PART NO.  
SIZE  
DOUBLE CHECK VALVE  
BRASS DRAIN COCK  
15PTSV  
22PTSV  
15 x 1/2”  
22 x 3/4”  
Suitable for central heating systems  
PART NO.  
SIZE MM  
Suitable for central heating systems.  
15DCV  
15  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
SUPERSEAL PIPE INSERT  
COLLET LOCKING CLIP  
BRASS CHROME PLATED BALL VALVE  
PART NO.  
SIZE MM  
PART NO.  
SIZE MM  
10  
STS10  
STS15  
STS22  
STS28  
10  
15  
22  
28  
CM1810S  
CM1815S  
CM1822S  
CM1810W  
CM1815W  
CM1822W  
PART NO.  
SIZE MM  
15  
10BV  
15BV  
22BV  
10  
15  
22  
To be used only when connecting  
Speedfit Pipe and Speedfit Fittings  
to enhance the sealing security of  
the connections. See page 05.  
22  
PART NO.  
SIZE MM  
Grey  
White  
10  
15BDC  
15  
15  
Suitable for central heating systems.  
Suitable for central heating systems.  
Manufactured in DZR Brass.  
Suitable for central heating systems.  
22  
Please note a collet cover cannot be used on  
a Speedfit end assembled with a draincock.  
Draincocks can be fitted with a standard  
fitting fitted with a collet clip.  
CM1810R  
CM1815R  
CM1822R  
CM1810B  
CM1815B  
CM1822B  
10  
15  
22  
10  
15  
22  
Red  
Blue  
PIPE INSERT  
When using with Twist and Lock Fittings  
the fitting must be locked.  
Each Valve has a red and a blue indice.  
PART NO.  
SIZE MM  
10  
TSM10N  
TSM15N  
TSM22N  
TSM28N  
PLASTIC SERVICE VALVE  
PLASTIC BALL VALVE  
15  
To be used when connecting Speedfit Pipe  
to a compression fitting.  
See Page 16.  
Suitable for central heating systems.  
PART NO.  
SIZE MM  
PART NO.  
15SV  
SIZE MM  
15  
22  
White and grey collet clips prevent accidental  
release of pipe from standard fittings.  
15SV-H  
22SV-H  
15  
22  
28  
22SV  
22  
Suitable for central heating systems.  
Red and blue clips provide colour coding of pipe,  
they should not be used to prevent accidental  
release of pipe.  
Not suitable for central heating systems.  
Hot and Cold water only, 65°C maximum.  
Not suitable for central heating systems.  
Each Valve has a red and a blue indice.  
13  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTION TO RING MAINS  
PIPE CLIPS AND SPACERS  
SYSTEM CONNECTIONS  
Water-replenishing ring mains are typically used in hotels  
and hospitals. They are maintained at a constant high  
temperature to supply hot water to distribution pipes to  
wards or hotel rooms which may be some way from the  
heat source.  
PART NO.  
PC15W  
PC22W  
PC28W  
SIZE MM  
15  
CONNECTION TO COMPRESSION FITTING  
Many but not all compression fittings are suitable for use  
with plastic fittings and pipe. Users should therefore  
check for compatibility. Compression fittings with short  
tube stop depth or brass olives should not be used with  
plastic fittings or pipe.  
22  
28  
PCSW  
PIPE AND PIPE ACCESSORIES  
These systems are very different from more conventional  
domestic hot water and central heating systems.  
When using compression fittings with Speedfit Pipe, a  
Standard Pipe Insert (prefix TSM) must be used to  
withstand the compressive pressure of the olive. The olive  
must be located within the the length of the pipe insert  
and the pipe fully inserted into the fitting. The connection  
should not need more than 2 full turns after the olive has  
gripped the pipe. JG Speedfit recommend the use of soft  
copper olives.  
Speedfit Products cannot be used on ring main systems.  
The exception would be those systems designed for  
domestic situations which have an intermittent  
temperature of less than a maximum of 65ºC. This is in  
accordance with BS7291 Parts 1 and 3 Class S.  
RELEASE AID  
NAIL CLIP  
PART NO.  
SIZE MM  
PART NO.  
NPC10  
NPC15  
NPC22  
NPC28  
SIZE MM  
10RA  
15RA  
22RA  
28RA  
10  
15  
22  
28  
10  
15  
22  
28  
CONNECTION TO BOILERS  
Ensure nut and olive are in place before inserting pipe insert.  
Speedfit pipe should never be connected directly to a boiler.  
Allows a firmer grip on the  
collet when removing pipe.  
FOIL TAPE  
Compression fitting  
Standard Pipe insert  
Although most modern boilers have  
a
high limit  
PART NO.  
SIZE MM  
X
M
thermostat, residual heat can be conducted by the heat  
exchanger. Therefore, Speedfit recommend a minimum of  
1 metre from the boiler casing should be run in copper  
pipe unless otherwise stated in the boiler manufacturers  
installation literature.  
JGTAPE  
50 x 45  
COLD FORMING BEND  
Olive  
Speedfit Pipe  
PART NO.  
SIZE MM  
Metallic tape to meet NHBC requirements  
for plastic pipe to be detected inside walls.  
A gravity primary circuit operating on an uncontrolled  
cooking range or solid fuel boiler should be run entirely in  
10CFB  
15CFB  
22CFB  
10  
15  
22  
CONNECTION TO IMPERIAL PIPE AND FITTINGS  
copper and the heating circuit run in copper for the first metre  
.
The Speedfit Range includes couplers to connect  
Speedfit Pipe to 1/2” to 1” BSP and BSPT. See page 12.  
10mm  
Refer to BS 5955: Part 8 for further clarification.  
Fittings to connect imperial  
pipe to metric pipe are  
shown on page 10.  
All appliances should have safety devices to make sure  
they cannot operate above the working temperature and  
pressure range set out in our Technical Checklist on page  
29. If safety devices are not incorporated within the  
appliance then external controls will be needed.  
PLUMBING SPARE PARTS  
15mm and 22mm  
To help create a tighter bend than  
the minimum with unsupported pipe.  
COLLETS  
CONNECTION TO CHROME-PLATED COPPER PIPE  
PART NO.  
SIZE MM  
Water meters (and other devices) can contain check  
valves that prevent the expansion of heated water back  
down the main supply from a combi boiler. If plastic pipe  
is to be used, a suitable expansion vessel must be fitted.  
This is especially important to consider if a water meter is  
fitted retrospectively. Speedfit do not recommend the use  
of plastic pipe on the main supply between a water meter  
and a combi boiler if an expansion vessel is not fitted.  
Speedfit fittings can be connected onto chromium plated  
copper pipe if the chromium plating is completely  
removed to the full depth of the fitting. To ensure  
maximum grip, the fitting of a collet clip is recommended.  
It is not possible to connect Speedfit fittings to Stainless  
Steel Pipe.  
For Standard Fittings  
PXC 10  
10  
15  
22  
28  
PXC 15  
SPF 22  
PXC 28  
BENDING SPRING  
PART NO.  
SIZE MM  
For Twist and Locks Fittings  
PXC 10  
10  
15  
22  
28  
JG-BS10  
JG-BS15  
JG-BS22  
10  
15  
22  
PXC 15  
PXC 22  
PXC 28  
Collet clip  
Speedfit Products should not be fitted to a sealed system  
oil boiler, back fired boiler or other uncontrolled heat source.  
Please also see Drop-Pipe Systems on page 17 and  
System Commissioning and Flushing on page 21.  
EPDM ‘O’ RING  
PIPE CUTTER  
PART NO.  
SIZE MM  
CONNECTING TO OTHER PLUMBING FIXTURES  
PART NO.  
10 EPR  
15 EPR  
22 EPR  
28 EPR  
10  
15  
22  
28  
As shown in the Product Range List, the Speedfit range of  
fittings includes valves, taps, adaptors and connectors for  
the plumbing of all typical domestic appliances and fittings.  
CONNECTION TO MAINS SUPPLY  
JG-TS  
In modern properties, water enters a building usually in  
blue MDPE (medium density polyethylene) pipe. In order  
to comply with Water Regulation Schedule 2.10, the  
internal plumbing system should be connected via a  
Speedfit Stop Valve (Part Nos. 15STV and 22STV) in  
conjunction with a PE-Copper Coupler from the Speedfit  
range of Underground Fittings.  
For up to 22mm size pipe.  
CONNECTION TO CYLINDER & WATER HEATERS  
Speedfit can be used on sealed and open vented heating  
systems, where boilers are either heating a hot water  
storage cylinder or instantaneous hot water such as a  
combination boiler. The temperature and pressure limits  
of the system must not exceed the maximum values stated  
under the heading ‘Working Temperatures and Pressures’.  
THREAD WASHER  
HEAVY DUTY PIPE CUTTER  
Speedfit Pipe  
Connection of Speedfit  
pipe to supply pipe of other  
materials should be via a  
stop tap with a 15mm or  
22mm compression outlet.  
with Superseal Pipe Insert  
PART NO.  
SIZE  
PART NO.  
1/2 EPW  
3/4 EPW  
1/2  
3/4  
JG HDC  
Stop valve  
BLADE-JGHDC  
When using a traditional copper vented cylinder Speedfit  
pipe and fittings can be installed with direct connections  
to the cylinder.  
For use with Female Coupler/Tap Connector.  
Copper pipe  
PE copper coupler  
For up to 28mm size pipe.  
15  
16  
MDPE pipe with  
Pipe Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CONTINUITY CONT’D  
CONNECTION TO PUMPS AND VALVES  
INSTALLING PIPEWORK  
IEE Guidance Note 7 provides useful guidance on the  
design of electrical installations where there is increased  
risk of electric shock. It recognises that the requirement  
for supplementry bonding may be relaxed where metal  
taps and plastic pipes supply other bathroom fittings.  
Speedfit pipe should be connected to circulating pumps,  
motorised valves in accordance with the section in this  
book headed, “Connecting Plastic Pipe To Compression  
Fittings”. If Speedfit pipe is not mounted on a supporting  
structure, the pipe must be clipped close to the components’  
connections to ensure adequate support and to assist in  
the reduction of vibration.  
SPEEDFIT BARRIER PIPE  
Speedfit Barrier Pipe is manufactured to BS 7291 Parts 1,  
2 and 3 Class S and is Kitemarked.  
CONNECTION TO CYLINDER & WATER  
HEATERS CONTINUED  
It is made up of 5 layers, the  
centre of which is a blue  
coloured oxygen barrier  
which prevents the ingress  
of air into the system, thereby  
reducing the effect of corrosion  
on metal components.  
Similarly a metal bath or radiator not connected to an  
extraneous-conductive-part is not required to be connected  
to the local supplementry conductors.  
Unvented pressurised cylinders can be installed using  
Speedfit Pipe and Fittings. However, insertion depths on  
compression joints that form part of the cylinder must be  
checked prior to installation and the use of standard pipe  
inserts (Prefix TSM) is recommended.  
For heavier equipment, ensure that appropriate metal  
brackets provide full and independent support of the  
components and that it does not rely solely on the pipework  
for support.  
In accordance with current U.K. Building Regulations  
(Part G), discharge pipes from temperature and/or pressure  
relief valves must be run in metal pipework.  
WATER HEATERS  
Earth Lead  
Because of it’s low thermal conductivity, when carrying  
hot water, Speedfit Pipe is cooler and therefore safer to  
touch. Relatively low heat loss through radiation means that  
a system retains it’s heat longer and delivers hot water  
more quickly and with less wastage than a metal system.  
Speedfit recommend that mains supply pipework to unvented  
water heaters (up to 15ltr capacity), be run in metal pipes.  
Clip  
Clip  
Metal  
Pipe  
Metal  
Pipe  
Speedfit connections to combined Cylinder/Boiler  
units and Thermal Storage Units must be made outside  
the casing unless otherwise stated in manufacturers  
installation literature.  
UNVENTED PRESSURISED CYLINDERS  
Speedfit Pipe and Fitting  
Unvented Pressurised Cylinders can be installed using  
Speedfit pipe and fittings. However if the safety  
parameters of the cylinder exceed those of the pipe and  
fittings it is possible to fit a pressure reduction valve on  
the out going hot supply pipe. This will not interfere with  
any other cylinder safety devices demanded by  
regulations as they are all fitted in the incoming side of the  
cylinder. Run a short length of copper pipe from the  
cylinder connection (about 150mm - 300mm) then fit a  
Honeywell DO5F pressure reduction valve. This will  
protect the pipe and fittings from excessive pressure in  
the event of boiler / cylinder malfunction. The factory  
fitted temperature / pressure relief valve on the cylinder  
will discharge below 100˚C therefore protecting the pipe  
from excessive temperature.  
SUPPLEMENTRY BONDING TO BATHROOMS  
22mm Barrier-PB to BS7291-2 2001 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C  
Pipe  
Supplementary Bond Comments  
Required Between  
DROP-PIPE SYSTEMS  
Material  
Care should be taken when designing and installing a  
central heating system where radiators are supplied by  
pipe work which drops from an upper floor.  
15mm B-PEX to BS7291 : Part 3 : 1990 Class S  
12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C  
Cold  
Hot Central  
Water Water Heating  
Earth terminals of  
protective conductors of  
class I and of class II  
equipment and accessible unless the bath is  
exposed conductive parts connected to the  
of the building structure.  
Bonding of metal taps  
metal radiatorsor metal  
baths is not required  
P
P
P
P
The pipe is available in coils and straight lengths. See  
pages 14. Pipe markings are spaced to aid the making of  
a good connection when using a Superseal Pipe Insert.  
With this kind of system it is possible to trap air in the  
upper floor pipe work. When the boiler is fired the increase  
in pressure within the pipe caused by expanding air could  
cause the pipe to burst.  
metallic building structure.  
Hot water pipe, central  
heating pipes, earth  
terminals of protective  
A bond is not required  
to the taps either hot  
nor cold, or to metal  
M
M
It is therefore essential that the system be designed so  
that any air can be removed from the system either  
automatically or manually by installing automatic or  
manual air vents at the highest points of the system.  
PIPEWORK SIZING  
conductors of class I and baths unless connected  
For general guidance on pipework sizing, please refer to  
BS6700 or the Institute of Plumbing Engineering Services  
Design Guide. Speedfit fittings are suitable for pipes  
within 0.1mm of nominal size. They can be used with  
copper pipe to BS EN 1057 or Speedfit plastic pipe.  
class II equipment and  
accessible exposed  
conductive parts of the  
building structure.  
to the metallic  
building structure.  
PREVENTING BACK FLOW  
DISCHARGE PIPES  
The Speedfit range includes  
(Part No 15DCV) to enable installers to comply with Water  
Regulation Schedule 2.15,  
a
Double Check Valve  
P
P
M
M
P
Central heating pipes, the Bonding of metal water  
earth terminals of  
protective conductors of  
class I and class II  
equipment and access to building structure.  
exposed conductive parts  
of the building structure.  
Speedfit pipe should not be used to provide the discharge  
from unvented cylinders, unvented water heaters and sealed  
systems via the temperature relief and pressure relief values.  
taps is not required,  
nor metal baths unless  
connected to the metallic  
The Product Range List shows the fittings available for  
reducing pipe diameters within the system.  
thus preventing contamination  
of  
water  
arising  
from  
CONNECTION TO COPPER PIPE  
back siphonage, backflow or  
cross connection.  
Speedfit pipe is available in straight lengths and coils.  
The minimum distance to make a solder connection on  
copper pipe inserted into a Speedfit Fitting is 450mm  
(18 inches). Ensure that any residual flux solder is not  
allowed to come in contact with the fitting. That same  
measurement is the safe distance to use a freezer kit to  
Speedfit Pipe.  
M
M
M
M
All metal pipes,  
Metal pipes themselves  
can be used as bonding  
conductors if joints are  
metal to metal and  
RADIATOR CONNECTIONS  
Pipe Diameter  
earth terminals of  
protective conductors  
class I and class II  
Straights  
Coils  
2m  
3m  
6m  
-
-
-
15mm 22mm  
-
The most common way of running pipework to a radiator  
is to run both flow and return pipes central to the  
radiator position.  
equipment, and accessible electrically continuous.  
exposed conductive parts  
of the building structure.  
15mm 22mm 28mm  
15mm 22mm 28mm  
The pipes exit  
a
single  
All metal pipes,  
earth terminals of  
protective conductors of  
class I and class II  
equipment, and accessible  
exposed conductive parts  
of the building structure.  
Metal central heating  
radiator does not  
require bonding.  
25m 10mm 15mm 22mm  
50m 10mm 15mm 22mm  
-
-
-
-
-
CONNECTING TO COLD WATER STORAGE TANK  
gang box (fitted with rubber  
grommets) located at the  
mid height of the finished  
radiator position. This also  
provides a fixed point for  
other trades to work to and  
reduces the risk of damage  
to the pipework.  
To install the Speedfit Tank Connector, unscrew the nut  
and push the body of the fitting through the tank hole with  
the washer on the inside of the tank.  
100m 10mm 15mm  
-
-
-
120m  
150m  
-
-
15mm  
15mm  
Hand tighten the nut onto the body. Push the pipe into  
the connector.  
P = Plastic M = Metal NB: All Waste Pipes are plastic.  
1. Supplementary bonding is carried out to the earth terminal  
of protective conductors of class I and class II equipment  
within the bathroom. A supplementary bond is not run  
back to the main earth.  
Note: Hand tightening the nut onto the body is all that is  
required. Further mechanical tightening will damage the fitting.  
METAL FOIL TAPE  
Once the plasterboard is installed the pipes are passed  
through the Speedfit Radiator Outlet Plate to exit  
plasterboard without the need of unsightly holes.  
Maximum wall thickness of tank 4mm  
JG Speedfit aluminium foil tape can be used to fulfil the  
NHBC requirements for the identification of location of  
plastic pipes in or behind a wall surface by a metal  
detector. It features a bright aluminium finish, rubber/resin  
high-tack adhesive and quality siliconised backing paper  
to allow the easy handling of short, cut lengths.  
Cold water tank  
Hole dia.  
2. Metal window frames are not required to be supplementary  
bonded unless they are electrically connected to the  
metallic structure of the bonding.  
Metal reducing sets which convert radiator valves from  
15mm to 10mm are not suitable for use with Speedfit  
Fittings or Pipe as they can cause damage to the plastic.  
15mm pipe  
22mm pipe  
28mm pipe  
29mm  
36mm  
46mm  
3. Metal baths supplied by metal pipes do not require  
supplementary bonding if all the pipes are bonded and  
there is no other connection of the bath to earth.  
ELECTRICAL CONTINUITY  
DO NOT stick the tape to the Speedfit pipe or fittings  
or those of any other manufacturer.  
The plumbing or heating system installer should have  
these aspects checked to ensure compliance with current  
IEE regulations. If in doubt please contact the Speedfit  
Technical Advisory Service or your local Electricity Authority.  
4. All bonding connections must be accessible and labelled  
Washer  
“Safety Electrical Connection - Do Not Remove”.  
17  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PIPE SIZING  
TIMBER I BEAM JOISTS  
WET PLASTER  
For general guidance on pipework sizing, please refer to  
BS6700 and BS5449 or the Institute of Plumbing  
Engineering Services Design Guide. Speedfit fittings are  
suitable for connection to pipe sizes within 0.1mm of  
nominal size.  
Several types of joists are available and Speedfit recommends  
that specific manufacturers details are consulted.  
However, the following can be used for general guidance.  
To prevent surface damage to the plaster caused by  
expansion and contraction of Speedfit pipes, it is  
important to ensure that all Speedfit pipework is  
channelled into the wall and protected with appropriate  
sleeving. Alternatively, the pipework can be surface  
mounted and boxed in if required for aesthetic appearance.  
Holes may be located vertically anywhere in the web,  
but leave 3mm web at the top and/or bottom of hole.  
Do not cut into joist flanges when cutting the web.  
PIPE BENDING  
Gentle bends can be made with pipe clips on either side  
of the curve, positioned to maintain the bend radius.  
The maximum heat carrying capacity and flow of Speedfit  
pipe, based on 1.2m/s velocity and an 11ºC temperature  
drop is shown in the table below.  
If more than one hole is to be cut in the web, the  
distance between the edges of the holes must be at  
least 2x diameter of the largest hole.  
Tighter bends can be achieved  
by using the cold forming  
bends shown on page 15.  
LAYING OF PIPE IN CONCRETE AND MASONRY  
Pipe size Max Capacity Max Flow  
Headloss  
m/m pipe  
Speedfit pipe and fittings can be laid in concrete and  
masonry providing they are installed in conduit pipe with  
access boxes for the fittings. As stated in Water  
Regulation Schedule 2.7 and BS 8000 : Part 15, fittings  
and pipe should be removable for possible replacement.  
Insulation is also recommended to protect against heat  
loss and the effects of frost.  
KW  
litres/sec  
Generally joists are manufactured with 38mm  
perforated knockouts in the web at approximately  
300mm centres along the length of the joist.  
10mm  
15mm  
22mm  
28mm  
1.948  
5.941  
13.604  
21.991  
0.042  
0.283  
0.139  
0.084  
0.062  
Internal Bending Springs are  
available in 10mm to 22mm  
sizes, see page 15.  
0.129  
0.295  
CROSS WEB JOISTS  
0.478  
Unlike I beam joists, pipe can be cabled anywhere within  
the open Web as no drilling is required. However, the top  
and bottom flanges must not be notched. Avoid  
damaging the outside diameter of the pipe as you cable  
Speedfit Conduit Pipe is supplied  
in either 15mm or 22mm in coil  
lengths of 25m or 50m. The flexible  
convoluted pipe has an outside  
diameter of 24mm and 30mm.  
PIPEWORK INSULATION  
The insulation requirements for Speedfit pipe are the same as  
those for copper and should comply with BS6700 and BS5422.  
It is also possible to bend Speedfit Pipe using a standard  
pipe bender. The pipe should not be heated with a  
blowlamp or hot air gun.  
through the metal cross web members  
.
CONCEALED PIPEWORK  
Minimum bend radii for Speedfit pipe are as follows:  
The flexibility of Speedfit pipe gives it the ability to be  
threaded through concealed or inaccessible spaces  
without disruption to surrounding structures, making  
major savings in installation time.  
Min Radius  
Pipe Diameter  
EXPOSED PIPEWORK  
10mm 15mm 22mm 28mm  
On long exposed runs of pipework, the expansion of  
Speedfit pipe when warm (1% on length between 20 to  
82°C) can cause it to sag between clip fixings. When this  
is undesirable, pipework can be boxed in or replaced with  
rigid copper pipe. Speedfit pipe and fittings are stabilised  
to withstand limited exposure to ultra-violet radiation in  
sunlight but are not designed for permanent direct  
exposure. Under such conditions painting or lagging is  
required. Pipe and fittings should also be lagged to  
prevent frost damage.  
with Cold Forming Bends 30mm 75mm 110mm  
-
Pipework can be “cabled” through drilled holes in joists  
and rafters. Therefore, pipework can be installed after  
floorboards have been laid, working below the floor  
before the ceiling is installed.  
with Clips 100mm 175mm 225mm 300mm  
For bends of radii smaller than those shown, standard  
elbow fittings are recommended.  
TIMBER FRAMED CONSTRUCTION  
This makes site work far safer as the installer does not  
have to balance on open joists with the risk of dropping  
tools or equipment on other people below.  
Speedfit is well suited for timber frame construction.  
Ensure that the structural integrity is not compromised  
when installing the pipework.  
PIPE SUPPORT AND CLIPPING  
There are two types of pipe clip in the Speedfit range.  
Firstly, a nail clip is used for fixing to timber  
when running concealed pipe work i.e.  
underfloor or in a roof space . This clip takes  
less time to fit and is compact which allows  
pipework to be fixed close together when  
space is at a premium.  
Speedfit pipe  
Joist  
If the pipe passes through an external wall, care must be  
taken not to damage the vapour barrier and should be  
installed on the inside of the thermal insulation layer.  
CHEMICAL EFFECTS  
Clips  
Only water or oil based paints should be used. Do not  
allow Speedfit fittings to come into contact with cellulose  
based paints, paint thinners or strippers, solder flux or  
acid based descalents or aggressive cleaning products. If  
there is a risk of any chemical treatments coming into  
contact with Speedfit, please contact the Technical Advisory  
Service first to check compatibility.  
If this is not possible, the use of conduit should be specified  
at the design stage.  
This will also eliminate the risk of damage by floorboard  
nails. There is no need for dry runs since pipe can be cut  
and connections made in-situ.  
The second type uses a screw and therefore  
takes a little longer to fix. When pipes are  
required to cross over, it is possible to add  
a spacer to the clip. This will give room  
between the pipe and the wall to allow the  
pipes to cross over. If pipework needs to be  
insulated, using the spacer will give room for  
the lagging to be applied.  
STEEL FRAMED CONSTRUCTION  
Rigid pipe, such as copper, can only be fed under floor in  
short lengths. However, Speedfit pipe, being flexible, can  
run from one fitting to another without having to install a  
connector in between.  
Speedfit is well suited for steel frame construction and  
care should be taken when installing the pipework.  
FLUXES AND SPEEDFIT  
All runs should be installed through preformed holes in the  
structure and protected by a rubber or plastic grommet.  
JG Speedfit does not recommend that fluxes of any type  
come into contact with our pipe and fittings. However, if  
fluxes are to be used in an environment where Speedfit  
is installed then we recommend installers use non-acidic  
and zinc chloride free fluxes such as Fernox Flux.  
Speedfit needs no jointing materials, eliminating the risk of  
fire from the use of a blowlamp, solder and flux  
.
Where clipping of pipework is restricted, cable ties may  
be used to secure the pipe.  
Pipe clips should not be fitted any closer than 60mm from  
the end of the fitting to allow for expansion. Pipes should  
always be adequately supported to prevent undue stress  
or side load on the fittings.  
TRADITIONAL JOISTS  
Instructions on the drilling of joists is given in the Building  
Regulations Approved Document A, and summarised as  
follows:  
As with all installations, make sure that any pipework passing  
through walls and floors does not affect the fire resistant  
properties of the structure.  
ACOUSTIC  
RECOMMENDED CLIP SPACING  
For surface mounted pipes  
1. Holes should be no greater than 0.25 of the depth of the joist.  
2. Holes should be drilled at the neutral axis.  
Properly installed, Speedfit pipes are virtually silent in  
operation and do not resonate; they absorb the acoustic  
vibrations and pressure waves created by cavitations,  
water hammer, float operated valve oscillation and other  
hydraulic effects. The inherent flexibility of Speedfit pipe  
effectively eliminates these troublesome problems, including  
those that occur when, due to thermal expansion, metal  
pipes rub against structural members and where long,  
straight runs of rigid pipe amplify water borne noise.  
DRY LINED WALLS  
Pipe Diameter  
Clip Spacing  
3. Holes should not be less than 3 diameters (centre to centre) apart.  
Speedfit pipework can be easily cabled through studwork  
and within wall systems as well as behind “dot and dab”  
plasterboard installations. Speedfit 10mm Barrier Pipe is  
most commonly used to feed radiators.  
Horizontal Run Vertical Run  
4. Holes should be located between 0.25 and 0.4 times the span  
from the support.  
10 - 15mm  
22mm  
300mm  
500mm  
800mm  
500mm  
800mm  
Min 3 x hole dia.  
If incorporating fittings in this way, collet covers or collet  
clips must be used with the Standard range of fittings.  
28mm  
1,000mm  
D
19  
20  
Max. dia. of holes = 0.25D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
During the commissioning of a heating system, all air  
must be removed from the system before the boiler is  
allowed to fire. This will ensure pockets of air do not  
cause localized overheating within the system as this  
could have a detrimental affect on the pipework and  
boiler.  
RADIATOR SYSTEM AND HEAT GRADIENT  
By contrast, radiators transfer heat from a relatively small  
area at a much higher temperature than the space being heated.  
The radiator system heats mainly by convection. This  
results in the floor being the coolest place in the room,  
with the mass of warm air at ceiling level.  
UNDERFLOOR HEATING  
PROTECTION AGAINST RODENTS  
The Speedfit Underfloor Heating System has been designed  
to be as quick and easy as possible to install with component  
parts manufactured to UK and European standards.  
When used in locations vulnerable to rodent attack, all  
plastic pipes and fittings should be adequately protected  
within sealed ducts.  
For further advice on chemical flushing agents and  
inhibitor treatments, the following manufacturers should  
be contacted: Fernox Manufacturing Ltd., 01799 550811  
or Sentinel Betz Dearborn Ltd., 0151 420 9595.  
Underfloor heating provides the most comfortable even warmth  
of any heating system. It is economical to run and virtually  
maintenance free. The principle has been with us since  
Roman times but is still the system of choice in some  
European countries, accounting for 70% of installations.  
Speedfit products along with other materials such as  
electrical cables may be damaged if rodents are present.  
If vermin infestation is suspected then a rodent exterminator  
Ceiling  
24°C  
TECHNICAL ADVISORY SERVICE  
The JG Speedfit Technical Advisory Service is available to  
assist and advise on all aspects of using the Speedfit  
system. The service is available between 8.00am and 4.30pm,  
Monday to Friday on Telephone No. 01895 425333 and  
Fax No. 01895 425350. Products within this Product Guide  
are designed for use within UK plumbing and heating  
installations or in other countries where similar installation  
requirements apply. For information on products suitable  
for use in other countries please consult our Technical  
Advisory Service.  
should take appropriate action  
.
BIOLOGICAL  
The Speedfit System has water being pumped from a  
boiler to a pump pack, where it is mixed to approximately  
50ºC then distributed via a manifold to heating circuits  
made using Speedfit Barrier Pipe. The pipe is laid in  
concrete or suspended just below the surface of the floor.  
No taste, colour, odour or toxicity is imparted to water by  
Speedfit components, nor do they promote  
microbiological growth.  
Floor  
18°C  
In accordance with BS7291: Part 1 Clause 6.7, the opacity  
of both pipes and fittings allows insufficient light to pass  
for the growth of algae  
In concrete floors, the pipe is laid on insulation and then  
covered with a screed on which can be laid almost any type  
of floor covering.  
FEATURES & BENEFITS  
We take pride in the quality of our products and all complaints  
are investigated thoroughly. If you have a problem with a  
Speedfit Product please return both fitting and pipe to us  
for investigation. We will need at least 50mm of pipe to  
ensure an accurate analysis. If there is a suspicion that the  
pipe is faulty, please provide marking details from the pipe.  
The Speedfit Underfloor Heating System offers many benefits  
to the consumer. These include:  
Tests within the Water Regulations Advisory Scheme,  
have approved Speedfit pipe and fittings to BS 6920 for  
water quality.  
For timber floors, spreader plates are laid between the joists  
and the floor decking or on the underside of the floor.  
Speedfit Pipe is pushed into the grooves on the plates.  
Installation  
It is simple to install, requiring the minimum of installation  
effort and little maintenance.  
SYSTEM TESTING  
The floor area is typically warmed to between 25ºC and  
28ºC, providing an even distribution of heat at only slightly  
higher than room temperature. The system is controlled  
by one or more thermostats which signal the Pump Pack  
when heat is required.  
On completion of the plumbing and heating system it is  
essential that system checking and a hydraulic wet test  
takes place. Connections to boilers, radiators and  
sanitary ware should first be capped or plugged.  
Comfort  
The system uses radiant heat, the most comfortable form  
of heating, to give a good even distribution of warmth  
over the whole room.  
COMMON PROBLEMS AND IDENTIFICATION  
Problem: Burst or melted pipe.  
Testing should be carried out at  
2 bar for 10 minutes followed by 10  
bar for 10 minutes.  
Pipe will be distorted showing either a ‘Parrot beak’ look  
or a long opening with the edges of the pipe melted in a  
wave shape.  
Space  
UNDERFLOOR HEATING SYSTEM  
The system in unobtrusive and space saving which means  
every square metre of floor and wall space can be fully  
utilised giving freedom of interior design.  
An Underfloor Heating System heats mainly by radiation.  
Radiant energy is emitted by the floor giving an even  
distribution of heat. No cold spots, hot ceilings or cold feet.  
This testing combined with other  
relevant checks, should reveal most  
system problems. Any components  
within the system not designed  
to take these pressures should  
be disconnected.  
Identification: A ‘Parrot beak’ will have been formed by  
the pipe bursting due to the water freezing. If the Pipe has  
a melted appearance it will have been subject to a  
temperature in excess of 128 degrees Celsius. This will  
have been caused by direct contact with a heat source  
such as a blowtorch or flue pipe or by water or steam  
within the system rising above safety levels.  
Noise  
Compared to radiator systems the system is virtually silent running.  
The overall effectiveness of an UFH heating system can  
be seen below.  
Health  
Dust is minimised reducing the problem of house dust  
mites. Reduced numbers of hot surfaces and sharp edges  
minimise risk of burns or injury.  
The heat is concentrated where it is most needed for  
comfort and efficiency.  
Before carrying out a pressure test  
ensure all Speedfit pipe and fittings  
are installed correctly. Speedfit  
Barrier Pipe is printed with insertion  
marks to help ensure full insertion  
has been achieved.  
Problem: A fitting or part of a fitting dissolved - the fitting  
may have blown off the pipe and may have missing  
component parts.  
Economic  
Underfloor Heating Systems are designed to operate at  
lower temperatures than radiator systems, resulting in  
reduced energy consumption and lower heatloss from the  
building structure.  
Ceiling  
18°C  
Identification: The fitting will have failed because of a  
chemical attack. The most common attack is from acid  
based solder flux running down into the fitting during  
soldering of a nearby copper fitting or flux coming into  
contact with the fitting in some other way.  
Remember pressure testing is NOT a substitute for  
making sure fittings are clean and free of any grit, dirt or  
swarf and the pipe is correctly inserted (see Making a  
Good Connection, on page 06.  
Control  
The system is easy to control and the small temperature  
difference between the floor and air means the system is  
virtually self - regulating.  
Problem: Weep from fitting.  
SYSTEM COMMISSIONING AND FLUSHING  
Environment  
Identification : The pipe has not been fully inserted up to  
the pipe stop or one or both of the ‘O’ rings have been  
damaged by burrs or sharp edges on the end of pipe. See  
‘What Not to Do’ on page 06.  
Floor  
24°C  
With existing systems, flushing prior to the use of Speedfit is  
essential to remove any harmful contamination or chemical  
residues from elsewhere in the system.  
Underfloor heating is suitable for use with the most energy  
efficient and environmentally friendly heating systems  
including condensing boilers, solar power and heat pumps.  
For the installation of central heating systems flushing  
procedures must be in line with BS7593 code of practice  
for treatment of water in domestic hot water heating systems.  
Problem: The fitting has blown off the pipe. Fitting is  
missing the collet, the pipe insert is still inside the fitting  
after the pipe has come out.  
FLOOR FINISHES AND COVERING  
The Speedfit Underfloor Heating System is suitable for  
most floor finishes, including ceramic tiles, carpets, vinyl  
and laminate.  
Flux residues used in the soldering of capillary fittings are  
very corrosive. Dirt and grit, which can enter the system  
when Speedfit pipe is being pushed through underfloor or  
across a roof space, must be removed.  
Identification: If this happens on first fix, the most likely  
reason is that the pipe has not been fully inserted into the  
fitting, up to the pipe stop, and the system has not been  
pressure tested.  
The thermal resistance of floor covering will have a marked  
effect on the performance of the heating system.  
Advice on the use of floor coverings and their effect on  
the performance of a system is laid out in the Speedfit  
Underfloor Heating Manual.  
If the collet (gripping device) is missing everything will  
blow out. If the collet is there and the pipe support is still  
inside the connector but the pipe has still blown out, this  
means that full insertion had not been accomplished.  
Floor  
Heating  
System  
Radiator  
Heating  
System  
Ideal  
Heating  
System  
21  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PEX BARRIER PIPE  
WET AREA PROBE + COVER  
SPREADER PLATES  
PART  
DESCRIPTION  
SIZE  
PACK  
QTY  
SPEEDFIT SYSTEM COMPONENTS  
Speedfit Underfloor Heating Products have been designed  
and are manufactured to European and UK Standards,  
including ISO 9001 and DIN4726.  
NO.  
PART  
DESCRIPTION  
PACK  
QTY  
PART  
DESCRIPTION  
PACK  
QTY  
NO.  
NO.  
15BPEX-50C  
BARRIER PIPE  
15MM X 50M  
15MM X 100M  
15MM X 120M  
15MM X 150M  
1
1
1
1
JGUFHTHKIT  
WET AREA PROBE + COVER  
1
JGUFHSP400  
390mm x 1000mm  
390mm x 250mm  
165mm x 1000mm  
1
1
1
15BPEX-100C BARRIER PIPE  
15BPEX-120C BARRIER PIPE  
15BPEX-150C BARRIER PIPE  
JGUFHSP250  
JGUFHSP165  
Used in conjunction with the Room  
Thermostat with set back control or  
Digital Room Thermostat, the kit is used  
in areas where the use of 240v would be  
a problem.  
Spreader Plates are available for timber flooring using either traditional joists or TJI Joists.  
MANIFOLDS  
POLYBUTYLENE BARRIER PIPE  
PART  
NO.  
DESCRIPTION  
PACK  
QTY  
PART  
DESCRIPTION  
SIZE  
PACK  
QTY  
NO.  
Spreader Plates 390 x 1,000mm and 390 x 250mm are  
laid across traditional joists and fixed in place using a  
hand stapler.  
JGUFHMAN4  
JGUFHMAN6  
JGUFHMAN8  
JGUFHMAN10  
JGUFHMAN12  
4 ZONE MANIFOLD  
6 ZONE MANIFOLD  
8 ZONE MANIFOLD  
10 ZONE MANIFOLD  
12 ZONE MANIFOLD  
1
1
1
1
1
15BPB-50C  
15BPB-100C  
15BPB-120C  
15BPB-150C  
BARRIER PIPE  
BARRIER PIPE  
BARRIER PIPE  
BARRIER PIPE  
15MM X 50M  
15MM X 100M  
15MM X 120M  
15MM X 150M  
1
1
1
1
A 3 metre long cable connects a non electrical probe to a  
room thermostat.  
DIGITAL ROOM THERMOSTAT  
Spreader Plates 165 x 1000mm can be used with  
traditional and TJI joists. They are fixed to the underside  
of the floor using staples or screws.  
PART  
DESCRIPTION  
PACK  
QTY  
NO.  
Offered in PEX or Polybutylene, Speedfit Pipe has an  
inner barrier to prevent the ingress of atmosphere, it is  
manufactured and Kitemarked to British Standard  
BS7291 : Parts 1,2 & 3: Class S.  
Supplied with Speedfit Pipe Inserts and Collet Clips.  
JGUFHTHDIG  
DIGITAL ROOM  
THERMOSTAT  
1
Speedfit Manifolds are manufactured from high quality  
DZR brass to the highest UK and European standards.  
Speedfit Pipe is fixed in the grooves of the plates.  
When the plates and pipework have been installed,  
insulation is placed in the void below the plates to  
minimise downward heatloss.  
Works in conjunction with a Centralised or Remote System Timer  
A unique feature is that connections to the heating pipes  
are Speedfit Push Fit, offering much reduced installation  
time. Flow and return rails are offset and the angles can  
be altered, all making for an easy installation.  
It is lightweight and flexible making it especially suitable  
for underfloor heating installations.  
A mains operated room thermostat. The temperature is  
set manually to ‘Daytime’ temperature and reduced by  
4oC to ‘Setback’ temperature by a Centralised or Remote  
System Timer. It has a manual override for permanent  
‘Daytime’ or permanent ‘Setback’ temperature and can be  
used in conjunction with a Wet Area Probe.  
For screed systems, the pipe is attached directly to  
insulation with staples, floor clips or mounting rails.  
The manifolds are complete with adjustable flow gauge,  
drain valve and air bleed valve. They are pre assembled  
on wall brackets and supplied with screws and plugs.  
Spreader Plates are available for timber flooring using  
either traditional joists or TJI Joists.  
ACTUATOR VALVE  
PART  
DESCRIPTION  
PACK  
QTY  
NO.  
PIPE FIXING SYSTEMS  
Speedfit offer several ways of securing pipe to the  
insulation layer in a screeded floor.  
MANIFOLD EXTENSION KIT  
JGUFHA(240 v) 240 v CIRCUIT ACTUATOR VALVE  
1
PROGRAMMABLE ROOM THERMOSTAT  
PART  
DESCRIPTION  
PACK  
QTY  
Actuators are attached to the individual  
heating circuits on the manifold, providing  
individual control to a room or zone.  
NO.  
PART  
DESCRIPTION  
PACK  
QTY  
NO.  
PART  
NO.  
DESCRIPTION  
SIZE  
PACK  
QTY  
JGUFHMANEXT MANIFOLD EXTENSION KIT  
1
JGUFHPRS  
PROGRAMMABLE ROOM  
THERMOSTAT  
1
Enables a manifold to be extended  
by one or more zones.  
They open or close the flow of water and are controlled  
by a thermostat or programmer.  
JGUFHSTAPLE  
JGUFHGUN  
PIPE STAPLES  
STAPLE GUN  
60mm  
-
300  
1
The Programmable Room Thermostat is a fully programmable  
electronic room thermostat which can be set to give each  
zone an individual time and temperature control.  
Black Staples are barbed to ensure a secure fixing to  
the insulation. Easy fixing is carried out by using a  
Staple Gun, securing pipe to the insulation with an  
easy repeatable action.  
MANIFOLD ELBOW CONNECTOR  
MASTER WIRING CENTRE  
PART  
PACK  
QTY  
NO.  
PART  
DESCRIPTION  
PACK  
QTY  
NO.  
CENTRALISED SYSTEM TIMER  
JGUFHMANELB  
1 PAIR  
PART  
DESCRIPTION  
PACK  
NO.  
QTY  
PART  
DESCRIPTION  
PACK  
QTY  
JGUFH4ZM  
MASTER WIRING CENTRE 4 ZONE  
1
Enables  
a
Pump Pack and  
NO.  
JGUFHRAIL  
JGUFHPIN  
2 METRE LONG  
16  
Manifold to be installed at 90º to  
each other.  
JGUFHTIMER-C CENTRALISED SYSTEM TIMER  
1
RAIL PINS FOR ABOVE  
100  
To be used with a Speedfit Set Back Thermostat.  
Mounting Rails offer a quick installation of 15mm pipe.  
Supplied 2 metres long, the rails are pre scored every  
100mm for easy cutting. The rail can be secured to the  
insulation using red Rail Pins.  
Used to connect the wiring from thermostat, actuators,  
boiler and pump and manage the control of the underfloor  
heating system.  
If specified, one timer is needed for each manifold in the  
system. The timer provides centralised control of the set  
back functions for the whole manifold via a digital  
programmer. The timer acts as a timed switch to alternate  
between ‘daytime’ and ‘Set Back’ time.  
PUMP PACK  
PART  
NO.  
DESCRIPTION  
PACK  
QTY  
PART  
DESCRIPTION  
PACK  
NO.  
QTY  
JGPUMPPACK  
PUMP PACK  
1
JGUFHCLIP  
FLOOR CLIP  
100  
1
Manufactured in DZR brass, the pack  
consists of a pump, mixing valve and  
overheat temperature thermostat.  
WIRING CENTRE SLAVE  
JGUFHTOOL FOR EASY FIXING OF FLOOR CLIPS  
PART  
DESCRIPTION  
PACK  
QTY  
REMOTE SYSTEM TIMER  
NO.  
Floor Clips screw easily into insulation, they  
are best installed using a Fixing Tool.  
PART  
DESCRIPTION  
PACK  
QTY  
NO.  
JGUFH4ZS  
JGUFH6ZS  
WIRING CENTRE SLAVE 4 ZONE  
WIRING CENTRE SLAVE 6 ZONE  
1
1
JGUFHTIMER-R  
REMOTE SYSTEM TIMER  
1
EDGE INSULATION STRIP  
Hot water is taken from the boiler, mixed to the required  
temperature and circulated via the manifold to the  
heating circuits, the temperature and volume of water is  
constantly altered to maintain the requirements of the  
system. Flow temperature can be altered by turning the  
hand wheel on the mixing valve unit.  
Connects to a Master Wiring Centre to  
give an additional 4 or 6 zones.  
PART  
DESCRIPTION  
PACK  
QTY  
NO.  
JGUFHEDGE  
25 METRE ROLL  
1
A 4 channel programmer. Ideal for installations where the  
system timer needs to be located away from the manifold.  
Can also be used, via a Master Wiring Centre, to control  
the set back for up to 4 Speedfit Room Thermostats. On a  
larger system the Remote System Timer can be used to  
replace a number of individual programmers, controlling  
say underfloor heating, radiators and hot water.  
Supplied in 25 metre rolls, the edge insulation  
strip is placed round the edge of each room to  
provide insulation of the heated floor.  
ROOM THERMOSTAT  
The pack is light and compact so a wall bracket is not  
needed and flat face unions make for an easy connection  
to the manifold.  
PART  
DESCRIPTION  
PACK  
QTY  
NO.  
FLOOR PANELS  
JGUFHTH  
ROOM THERMOSTAT WITH  
1
SET BACK TEMPERATURE REDUCTION MODE  
PART  
NO.  
DESCRIPTION  
PACK  
QTY  
Works in conjunction with a Centralised or Remote System Timer  
UNDERFLOOR HEATING SPARE PARTS  
JGUFHTILE  
Floor Tile  
12  
PART  
DESCRIPTION  
PACK  
QTY  
1400mm x 800mm  
A mains operated room thermostat. The temperature is set  
manually for ‘daytime’ temperature. A ‘set back’ mode,  
reducing the temperature by 4oC, is controlled by a Centralised  
or Remote System Timer. The Thermostat has a manual  
override for permanent ‘Daytime’ or permanent ‘Set back’  
temperature and can be used in conjuncton with a Wet Area  
Probe.  
NO.  
Supplied in packs of 12, Speedfit Floor Tiles  
have an 11mm layer of insulation for support  
and additional thermal insulation.  
SPUFH1  
SPUFH2  
SPUFH3  
SPUFH4  
SPUFH5  
SPUFH6  
MIXING VALVE CARTRIDGE KIT  
PUMP PACK FLOW TEMP GAUGE  
OVER HEAT STAT  
1
1
1
1
1
1
MANIFOLD FLOWMETER  
MANIFOLD BALANCING VALVE  
DUST CAP FOR BALANCING VALVE  
23  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SINGLE ROOM UNDERFLOOR HEATING PACK  
The floor is cleared  
of dust and debris  
and insulation is laid  
across the area.  
TIMBER FLOOR INSTALLATIONS  
SPEEDFIT SYSTEM COMPONENTS  
PART  
NO.  
DESCRIPTION  
PACK  
QTY  
JGUFHPACK20  
UNDERFLOOR HEATING PACK  
1
Spreader plates are available  
2
for timber flooring which  
uses either traditional  
joists or TJI joists.  
For conservatories or room extensions up to 20m .  
SINGLE ROOM CONTROL UNIT  
PART  
DESCRIPTION  
PACK  
QTY  
Pack contains: • Single Room Control Unit  
• Programmable Room Thermostat  
• 15mm x 150m coil Polybutylene Pipe  
with Pipe Clips and Pipe Inserts  
NO.  
JGROOMPACK SINGLE ROOM CONTROL UNIT  
1
The new Speedfit Underfloor Heating  
Control Unit is the ideal way to provide  
heating to a conservatory or room  
extension, up to 30m2.  
Speedfit Pipe is laid  
in a pre-determined  
pattern and fixed in  
position with staples.  
SINGLE ROOM UNDERFLOOR HEATING PACK  
Spreader plates 390mm x  
1,000mm and 390mm x  
250mm are designed for  
use with traditional joists  
at 400mm centres. They  
are laid across the joists  
and fixed in place using a  
hand stapler. The 15mm  
Speedfit Pipe is pushed  
into the grooves in the  
plate and the floor decking  
laid on top.  
The unit is pre-assembled and pre-wired  
to allow for a fast and simple installation.  
PART  
NO.  
DESCRIPTION  
PACK  
QTY  
The control unit has integral ball valves to allow for  
isolation from the primary heating system, an adjustable  
blending valve and a 6 metre head circulation pump. An  
anti-vibration mounting bracket ensures silent operation.  
JGUFHPACK30  
UNDERFLOOR HEATING PACK  
1
2
For conservatories or room extensions up to 30m .  
Pack contains: • Single Room Control Unit  
• Programmable Room Thermostat  
Speedfit push in connections make for a fast connection  
to pipework.  
• 2 x 15mm x 100m coils of Polybutylene Pipe  
• 300 x 15mm Pipe Clips  
Fit the Speedfit Manifold  
to the wall and connect the  
Pump Pack.  
• 8 x 15mm Pipe Inserts  
Speedfit recommend connection to the main central  
heating flow and return distribution system, but it is also  
possible to connect to the nearest radiator supply pipe.  
• 2 x 15mm Speedfit Equal Tees  
• 2 x 15mm Speedfit Swivel Elbows  
A full and detailed installation guide is provided with each unit.  
Insulation can be placed  
between joists to the  
underside of the plates  
either before or after the  
plates have been laid.  
The Speedfit Underfloor Heating Control Unit is suitable  
for use when:  
INSTALLATION IS QUICK AND EASY  
SOLID FLOOR INSTALLATIONS  
SCREEDS  
The boiler serving the existing heating system has  
the capacity to take the extra output from 2KW to 3KW  
Connect the ends of the  
pipes to the Manifold.  
The boiler is compatible with the additional pump  
The maximum area to be heated is 30 sq metres  
The screed is an important and integral part of the UFH  
system, transferring energy from the pipes to the area to  
be heated. The response of this ‘thermal mass’ will depend  
on its depth and make up.  
The Control Unit is designed to be used with Speedfit  
Barrier Pipe. The amount of pipe needed is determined  
not only by the size and shape of the room but by the  
resistance of the floor finish to heat transfer.  
Spreader plates 165mm x  
1000mm can be used  
with either traditional or  
TJI joists and with the  
floor already in place.  
They are fixed to the  
underside of the floor  
using staples or screws.  
The Speedfit Pipe is  
The usual depth of screed is 65 - 75mm thick but it is possible  
depths can be reduced to assist in improving performance.  
The system is filled and  
pressure tested.  
The table below shows examples of low resistance (tiles)  
and high resistance (carpet with underlay) finishes.  
PIPE LAYOUT IN SOLID FLOOR INSTALLATIONS  
The shape of the room and the position of the outside  
walls and windows will determine the pattern of the pipe  
layout. The counterflow pattern is recommended although  
other options are shown below.  
COIL SIZE TO AREA  
Part  
No.  
Coil Size Staples Max Area Temp/Tiles Temp/Carpet Max Output  
2
(m)  
Required  
(m )  
(ºC)  
(ºC)  
(KW)  
fixed in to the groove.  
15BPEX-150C 150  
15BPEX-120C 120  
15BPEX-100C 100  
15BPEX-50C 50  
240  
200  
170  
100  
20  
17  
14  
7
44  
44  
44  
44  
58  
58  
58  
58  
1.8  
1.5  
1.2  
0.6  
When the plates and  
pipework have been  
installed, the insulation  
is placed in the floor  
void to minimise  
The screed should be laid  
whilst the pipe is pressurised.  
downward heat loss.  
The underfloor heating  
system should not be used  
to dry the concrete screed.  
Single Serpentine  
Double Serpentine  
Triple Serpentine  
Counterflow  
25  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EQUAL TEE  
MAKING A GOOD CONNECTION  
PRODUCT RANGE  
PART NO.  
SIZE MM  
JG201B  
JG202B  
20  
25  
Cut pipe square using pipe cutters, remove burrs and  
sharp edges. Always use a pipe insert.  
EQUAL STRAIGHT CONNECTOR  
PART NO.  
SIZE MM  
Cold water only  
JG401B  
JG402B  
20  
25  
UNDERGROUND FITTINGS  
APPLICATIONS  
Cold water only  
Speedfit underground fittings for metric size polyethylene  
cold water service pipe have been designed for  
connection of:  
Pipe insert  
The fitting is supplied ready  
for installation and requires  
no adjustment. Push the  
pipe into the fitting.  
Push pipes into fitting  
Collet  
REDUCING STRAIGHT CONNECTOR  
1. Blue MDPE pipes to BS 6572 - used for underground  
PE-COPPER COUPLER  
service pipes for potable water.  
PART NO.  
SIZE MM  
PART NO.  
SIZE MM  
JG501B  
25 x 20  
JG601B  
JG603B  
JG602B  
20 x 15  
25 x 15  
25 x 22  
Collet Cover  
ʻOʼ ring  
2. Black MDPE pipes to BS6730 - used for conveyance  
of potable water above ground or for industrial  
services above or below ground.  
Cold water only  
Push the pipe up to the  
pipe stop. The collet has  
teeth that grip the pipe  
whilst the ‘O’ ring provides  
a permanent leak proof  
seal.  
Used to connect PE Pipe to  
copper or Speedfit Plumbing Pipe  
Cold water only  
Suitable for Tables X & Y Copper  
3. Pipe to ISO 161/1, ISO 3607 and DIN 16893.  
Making the connection could not be easier. All you need is  
the pipe, the fitting and a pair of hands. The range is  
designed to provide a long service life and includes adaptors  
for screwed pipe, copper and imperial sized LDPE.  
MALE ADAPTOR  
PART NO.  
SIZE  
JG101B  
JG102B  
20mm x 1/2” BSP  
25mm x 3/4” BSP  
TO DISCONNECT  
PIPE INSERT  
Ensure that the system is  
depressurised. Release and  
pull back collet cover.  
Push in collet square against  
the face of fitting.  
PART NO.  
SIZE MM  
Cold water only  
INSTALLATION BENEFITS  
UTS147 - DB  
UTS197 - DB  
20  
25  
Easy to use in confined spaces, no tools required.  
Fast installation with resulting cost savings.  
Lightweight and slimline.  
With the collet held in this position, the pipe can be withdrawn.  
FEMALE ADAPTOR  
We recommend the replacement of the ‘O’ ring and collet  
before making a new connection.  
PART NO.  
SIZE  
INCH CHANGE KIT  
JG4501B  
JG4502B  
20mm x 1/2” BSP  
25mm x 3/4” BSP  
Ready for immediate installation, no dismantling.  
No adjustments required after fitting.  
PART NO.  
SIZE MM  
JGK01E  
JGK02E  
1/2”  
3/4”  
CONNECTING TO IMPERIAL SIZE LDPE  
Using the Inch Change Kit shown on page 28.  
Cold water only  
Cold water only  
Adaptors for screwed pipe, copper and imperial LDPE.  
Remove collet cover, pull  
out metric size collet and  
‘O’ ring. Keep with metric  
pipe support liner for future use.  
To convert metric size fittings for  
use with imperial size LDPE to  
BS1972 Class C or Class D  
PERFORMANCE BENEFITS  
Maintenance free.  
PLUGS  
PART NO.  
SIZE MM  
Carefully push imperial size  
‘O’ ring and collet into  
position, ensuring seal is  
clean before insertion.  
Durable with high resistance to impact.  
Patented collet ensures high resistance to pull out.  
Lead free and non toxic.  
JG801E  
JG802E  
20  
25  
Cold water only  
SPARE PARTS  
Replace the snap-fit collet  
cover and, having inserted  
the imperial pipe support,  
connect the pipe as  
Will not support biological growth.  
COLLETS  
A reliable and trouble free leakproof connection.  
PART NO.  
SIZE MM  
EQUAL ELBOW  
shown above.  
20 UPC  
25 UPC  
20  
25  
PART NO.  
SIZE MM  
JG301B  
JG302B  
20  
25  
Cold water only  
‘O’ RING  
PART NO.  
SIZE MM  
20 UOR  
25 UOR  
20  
25  
STEM ELBOW  
PART NO.  
PIPE  
OD  
STEM  
OD  
JG222025B  
JG222525B  
20mm  
25mm  
25mm  
25mm  
27  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TECHNICAL CHECKLIST -  
UNDERGROUND FITTINGS  
TECHNICAL CHECKLIST -  
PLUMBING AND HEATING FITTINGS  
TECHNICAL CHECKLIST -  
UNDERFLOOR HEATING  
Fittings and pipe should be kept clean and undamaged before use.  
Chlorine. Speedfit is not suitable for use in systems where the water  
Applications. Speedfit Underground Fittings are designed to connect  
MDPE pipes (MRS-PE80) used above or below ground, to convey  
potable water from distribution mains to individual properties.  
Applications. Underfloor Heating Installations in solid or timber floors.  
Pipes. 15mm JG Speedfit Barrier Pipe to BS 7291, Parts 1, 2 and 3 Class S.  
contains high levels of chlorine. e.g. swimming pools, fountains etc.  
Sizes. 10mm to 28mm diameter.  
Exposure to sunlight. Speedfit products, when used indoors, are not  
affected by sunlight. When used outdoors protect from ultra violet light  
by lagging or painting.  
Pipe clips. Pipe clips should not be fitted any closer than 60mm from the  
end of the fitting. Pipe should be adequately supported by pipe clips to  
prevent undue stress (side load) on fittings.  
Pipes. Speedfit fittings can be used with:  
Sizes. 20mm and 25mm with adaptors for:-  
- Copper to BS2871 Part 1 / BS EN1057. Table X and Table Y.  
- Screwed pipe.  
DO NOT USE Speedfit UFH Products for Gas, fuel oil or compressed  
Copper pipe to BS EN 1057  
Speedfit Barrier Pipe to BS7291.  
air applications.  
- LDPE (to BS1972 Class C and Class D) in 1/2” and 3/4” inch sizes.  
Speedfit fittings cannot be used on stainless steel pipe.  
Floor Insulation. Should be a suitable material and thickness to comply  
Pipes. Speedfit Underground Fittings can be used with:-  
with current regulations.  
Standards. Speedfit products are designed and manufactured  
under a fully integrated system assessed by B.S.I. to BS EN ISO9001.  
They are approved by the WRAS and BBA. Speedfit PEM, PSE and SFM  
Fittings and Speedfit Barrier Pipe are Kitemarked to BS7291 Parts 1, 2  
and 3, Class S. (Licence No. KM39767)  
- Blue MDPE pipe to BS6572.  
- Black MDPE pipe to BS6730.  
Pipe inserts. Must be used on all installations when using plastic pipe  
Minimum Bending Radii. For Speedfit B-PEX Pipe is 175mm.  
Expansion (PEX - Pipe). 1% on length between 20˚C and 82˚C.  
- Pipes conforming to ISO161/1, ISO3607 and DIN16893.  
and should be fully inserted. Only use a Speedfit Insert with Speedfit Pipe.  
Working Temperatures and Pressures. Maximum working pressure  
Metal Joists. When ʻcablingʼ plastic pipe through metal joists ensure rubber  
grommets are in place to prevent damage to pipe. Use of collet covers or  
collet clips on fittings recommended.  
12 Bar @ 20˚C.  
Cleaners, Inhibitors and Descalents. For advice on the replenishment of  
additives such as corrosion inhibitors, the following manufacturers  
should be contacted Fernox Manufacturing Limited on 01799 550811 or  
Applications.  
Standards. Speedfit Underground Fittings are approved by the  
Mains fed and indirect cold water systems  
Vented and unvented hot water systems  
Vented and sealed central heating systems  
Connection to boilers. A minimum 1000mm run of copper pipe must be  
Water Regulations Advisory Scheme.  
Sentinel, BetzDearborn Limited on 0151420 9595.  
installed between the boiler and the Speedfit system, as per BS5955: Part 8.  
Performance. The fittings are manufactured from tough plastic  
material well able to meet the stringent requirements of the water  
industry. They have been approved by the WRAS and, as such,  
have passed the ʻpull out testʼ where a force shown below is applied  
to a connection between MDPE pipes and a fitting for 5 minutes  
without the connection failing.  
Connection to copper pipe. 450mm is the minimum distance to make  
a solder connection on copper pipe inserted into a Speedfit Fitting. Ensure  
that any residual flux solder does not come into contact with the fitting.  
Concrete and masonry. Speedfit pipe and fittings can be laid in concrete  
and masonry providing they are installed in conduit pipe with access boxes  
for the fittings. This is to enable the pipe to expand and provide accessibility  
for both pipe and fittings. As stated in Water Regulation Scheme 2.7 and BS  
8000 : Part 15, fittings and pipe should be removable for possible replacement.  
Insulation is also recommended to protect against heat loss and the effects  
of frost.  
Paint and Chemicals. Only use water or oil based paint. DO NOT ALLOW  
CONTACT WITH cellulose based paints, paint thinners or strippers, solder  
flux or acid based descalents or aggressive household cleaning products.  
Do not use for Gas, fuel oil or compressed air applications.  
Working temperatures and pressures  
Exposure to sunlight. Speedfit products, when used indoors, are not  
Application  
Usual working  
temperature, ºC  
Maximum working  
temperature, ºC  
Maximum working  
pressure, bar  
affected by sunlight. When used out doors protect from ultra violet light  
Size  
by lagging or painting.  
Cold Water  
(indirect and direct mains)  
20  
20  
12  
Test Force  
Newtons  
lbs  
20mm  
1900  
427  
25mm  
2500  
562  
Pipe Inserts. Must be used on all installations when using plastic pipe and  
Central Heating  
82  
65  
105, short term  
3
should be fully inserted.  
malfunction at 114  
Electrical Components. Electrical products in the Speedfit Underfloor Heating  
Hot Water  
(including unvented cylinders)  
95  
6
Electrical continuity. If Speedfit is used in an existing metal system which  
DO NOT USE FOR Gas, fuel oil or compressed air applications  
or hot water.  
Systems are designed only to be used in U.K. Electrical Supply situations.  
may have been used for earthing, electrical continuity should be reinstated.  
Valves and taps. Plastic 15mm and 22mm valves and taps available from  
Electrical Continuity. If Speedfit is used in an existing metal system which  
Burst Pressure (fittings). With copper or plastic pipe at 20°C: Speedfit  
fittings used with copper or Speedfit Barrier Pipe will withstand pressures  
well in excess of normal service conditions.  
JG Speedfit Ltd are not suitable for central heating installations.  
Chemical Effects. For below ground applications the fittings require  
no additional preparations - coating etc. When used above ground,  
avoid contact with aggressive chemical compounds. Protect from frost  
where necessary. In the United Kingdom, potable water does not  
contain high levels of chemicals (eg chlorine etc) that would adversely  
affect Speedfit Underground Fittings.  
may have been used for earthing, electrical continuity should be reinstated.  
Collet Covers. Collet covers provide added security against pipe  
disconnection, e.g. the fittings coming into contact with rigid surfaces  
and behind dry-lining walls. They are offered in white as standard and  
in red or blue to provide colour coding of pipe.  
Collet Clips. Grey collet clips are used with standard fittings to prevent  
accidental pipe disconnection. Red or blue clips provide colour coding  
of pipe. Red and blue clips should not be used to prevent accidental  
release of pipe.  
System testing. To ensure the pipework and fittings have been installed  
correctly, whether it be on a new or extended system, it is essential that the  
system is checked and hydraulically wet tested. Testing should be at 2 bar  
for 10 minutes and 10 bar for 10 minutes. This testing, combined with other  
relevant checks, should reveal installation problems and is regarded as good  
plumbing practice. However, system testing should not be regarded as a  
substitute for correct installation (see also “Making a Good Connection”).  
System flushing. As is usual practice for any plumbing installation, flushing  
of the system prior to the use of Speedfit is recommended to remove any  
contaminants/chemical residue from elsewhere in the system.  
British Gas Service has accepted the John Guest Speedfit fittings as being  
suitable for open vented and sealed central heating systems and as eligible  
for acceptance onto its service contracts.  
Vermin. Speedfit products will need special protection in vermin infested areas.  
Maximum Torque figures (BSP & BSPT). Plastic threads are not generally as  
strong as brass threads. Customers and end users should be aware of this  
when choosing products for their applications. Overtightening of plastic threads  
will cause undue stress and eventual cracking and leakage. The maximum  
torque figures for BSP and BSPT threads used on Speedfit plumbing products  
in mating threads conforming to the relevant BS or International thread  
standards are shown below.  
Collet Clips. White and Grey collet clips are used with standard fittings to  
prevent accidental pipe disconnection. Red or blue clips provide colour  
coding of pipe. Red and blue clips should not be used to prevent accidental  
High temperatures. Can withstand 114°C intermittently for short periods.  
The Speedfit system should not be used on an uncontrolled heat source.  
release of pipe.  
Insulation. Should comply with BS6700 and BS5422, as for copper.  
Exposure to sunlight. Permanent exposure to direct sunlight will  
Pre-Screed System Testing. To ensure the pipework has been installed  
Minimum bend radii (PEX)  
correctly and prior to the screed being laid, it is essential that the system  
necessitate lagging the fittings.  
Pipe diameter  
10mm 15mm 22mm 28mm  
100mm 175mm 225mm 300mm  
is checked and hydraulically wet tested.  
Pipe Inserts. Pipe inserts must be used and fully inserted on all  
Min radius with clips  
connections to MDPE or LDPE pipe.  
Testing should be carried out at 2 bar for 10 minutes and 10 bar for  
10 minutes.  
Min radius with cold forming bend 30mm 75mm 110mm  
-
System Testing. Pressure test to 1.5 times working pressure for 10  
minutes before connecting to the mains supply. It is recommended  
that all pipe and fitting installations are pressure tested after  
installation before handing over to the final user  
Clip spacing (in mm).  
This testing, combined with other relevant checks, should reveal installation  
problems and is regarded as good plumbing practice.  
For surface mounted pipes  
Pipe Diameter  
Clip Spacing  
Pressurisation During Screed Laying & Curing. In accordance with  
BS1264-4, the system should be left under pressure at a minimum of 6 bar for  
the duration of the laying and curing of the screed.  
Maximum Torque Figures. The maximum torque figures for BSP  
Horizontal Run  
Vertical Run  
500mm  
800mm  
and BSPT threads used on Speedfit products are as follows:-  
10 - 15mm  
22mm  
28mm  
300mm  
500mm  
800mm  
Size  
1/2  
3/4  
Maximum Torque  
3.0 Nm  
Under NO circumstances should the UFH System be used to quicken  
the screed drying process.  
1,000mm  
4.0 Nm  
System Flushing. As is usual practice for any plumbing installation,  
Where pipe is concealed, clipping may only be required where necessary.  
flushing of the system prior to the use of JG Speedfit is recommended to  
It is recommended that all installations are checked prior to use to  
determine that a seal has been made.  
The maximum torque figures quoted for use with Speedfit fittings are  
dependent on the mating thread conforming to the relevant British  
International thread standards.  
remove any contaminants/chemical residue from elsewhere in the system.  
Expansion (PEX pipe). 1% on length between 20°C and 82°C.  
Flow rates. Comparable with metal systems.  
Vermin. Speedfit products should not be used in vermin infested areas.  
Frost Protection. During the installation process it is important that pipe  
Cleaners, inhibitors and descalents. For advice on the replenishment of  
additives such as corrosion inhibitors, the following manufacturers should  
be contacted: Fernox Manufacturing Limited on 01799 550811 or Sentinel,  
BetzDearborn Limited on 0151 420 9595.  
containing water be protected from frost.  
Paint and Chemicals. Use only water or oil based paint. Collet covers  
prevent paint ingress into fittings. DO NOT ALLOW CONTACT WITH  
Threads  
Plastic  
Size  
1/2”  
3/4”  
1/2”  
3/4”  
Maximum Torque  
3.0 Nm  
4.0 Nm  
oil based jointing compounds, cellulose based paints, paint thinners, paint  
strippers, solder flux, acid based descalents or aggressive cleaning products.  
Brass  
4.0 Nm  
5.0 Nm  
Solder Flux. No fluxes of any types should come into contact with  
JG Speedfit Pipe and Fittings. If fluxes are to be used in an environment  
where Speedfit is installed, then (1) extreme care should be taken to ensure  
that no such contact takes place and (2) JG recommend installers only use  
fluxes tested and approved in writing in advance by JG. At the date of this  
It is recommended that all installations are checked prior to use to determine  
that seal has been made.  
Side Loads. Fittings should not be subject to excessive side loads and they  
should not be used as support brackets. Tubing and fittings should be adequately  
supported to prevent excessive side loading.  
publication, the only such approved flux is Fernox Flux.  
29  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Grinder 16574063 User Manual
Interex Projector MHL331D User Manual
Interquartz Telephone IQ331 User Manual
IOGear Network Card GBU241W6 User Manual
Jura Capresso Coffeemaker IMPRESSA701 User Manual
JVC Computer Monitor GD V422U User Manual
JVC Flat Panel Television 1004MKH VT VT User Manual
Kenmore Cooktop 7904380 User Manual
KitchenAid Cooktop KEC507BWH1 User Manual
Kodak Camera Accessories D 45 User Manual