Jenn Air Cooktop JRC120012A User Manual

JENN-AIR® DETAILED PLANNING DIMENSIONS  
1 of 4  
36" Jx3GAS DOwNDRAfT COOkTOP  
JGD3536W – 36" x 1838" x 2112"  
PRODUCT DIMENSIONS  
A
MODEL #  
JGD3536W  
in  
cm  
Overall width  
36  
91.4  
54.6  
87.7  
31.8  
46.8  
10.2  
3.4  
A
B
C
D
E
F
Overall depth  
2112  
3412  
1212  
1838  
4
B
Width of recessed cooktop  
Width of blower motor assembly  
Height from blower motor to countertop  
Height of recessed cooktop  
Height with grates  
138  
TOp VIEW  
G
H
I
Height from gas inlet to countertop  
Depth of recessed cooktop  
Height from plenum to countertop  
734  
19.8  
50.0  
42.8  
193/4  
1678  
J
A
G
C
F
H
E
D
FRONT VIEW  
B
I
J
E
SIDE VIEW  
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing  
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.  
JRC120012A 07/2012  
Download from Www.Somanuals.com. All Manuals Search And Download.  
JENN-AIR® DETAILED PLANNING DIMENSIONS  
3 of 4  
DUCT-fREE kIT  
JDA7000WX – 1758" x 1038" x 712"  
Jx3DOwNDRAfT COOkTOPS wITH DUCT-fREE VENTILATION  
The duct-free filter kit (JDA7000WX) is approved for use with JX3™ downdraft cooktop models  
JGD3536W, JGD3430W, JED4536W, JED3536W, JED4430W and JED3430W. The kit filters the air  
from the downdraft system and ventilates the conditioned air into the room through the toe kick  
of the base cabinet. Do not ventilate the air from the downdraft system into the base cabinet,  
base cabinet pedestal, crawl space, wall or attic.  
PRODUCT DIMENSIONS  
MODEL #  
JDA7000WX  
in  
1758  
1038  
712  
3
cm  
44.7  
26.5  
19.0  
7.6  
Width of housing  
A
B
C
D
E
Height of housing  
Depth of housing  
Minimum height of toe kick  
Minimum depth to toe kick  
B
212  
6.4  
A
EXHAUST CUTOUT LOCATION  
The cutout location in the toe kick area of the cabinet floor is  
dependent upon the dimensions of the cooktop and base cabinet.  
FRONT VIEW  
C
Airflow  
D
Floor  
E
SIDE VIEW  
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing  
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.  
JRC120012A 07/2012  
Download from Www.Somanuals.com. All Manuals Search And Download.  
JENN-AIR® DETAILED PLANNING DIMENSIONS  
4 of 4  
DOwNDRAfT COOkTOP DUCTING ARRANGEMENTS  
The diagrams below show typical duct arrangements for downdraft cooktops. JX3™ downdraft cooktops  
also offer a duct-free installation option. For more details, refer to page 3.  
DUCTING CONfIGURATIONS  
DUCTING REQUIREMENTS  
Roof jack  
COOKTOp  
DUCT LENGTH  
DUCT SIzE  
5" (12.7 cm)  
diameter*  
10' (3.0 m) or less*  
6" (15.2 cm)  
diameter  
314" x 10"  
Gas  
314" x 10"  
(8.3 cm x 25.4 cm) duct –  
54' (16.5 m) max.  
Between 10' (3.0 m)  
and 60' (18.3 m)  
(8.3 cm x 25.4 cm)  
5" (12.7 cm)  
diameter**  
10' (3.0 m) or less**  
6" (15.2 cm)  
diameter  
314" x 10"  
Electric  
Between 10' (3.0 m)  
and 60' (18.3 m)  
Transition elbow  
(8.3 cm x 25.4 cm)  
*Gas cooktops must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.  
**May be used to vent straight out the back of the cooktop and directly  
through the wall.  
CALCULATING MAXIMUM DUCTING LENGTH  
• Maximum ducting length is 60' (18.3 m).  
• Each 90° elbow equals 5' (1.5 m) duct.  
• Use no more than three 90° elbows.  
REAR DUCTING IN WALL TO ROOF  
• Flexible metal vent is not recommended.  
• Do not install two elbows together.  
NOTES:  
• For ducting runs up to 30' (9.1 m), install cooktop as shipped.  
• For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the  
restricter ring on the blower inlet housing.  
• For altitudes above 4500' (1272.0 m), reduce recommended  
vent run by 20% for best performance.  
REAR DUCTING THROUGH WALL TO OUTSIDE  
6" (15.2 cm) diameter duct –  
5112' (15.7 m) max.  
5" (12.7 cm ) to 6" (15.2 cm)  
diameter transition  
Transition elbow  
314" x 10"  
(8.3 cm x 25.4 cm) duct  
6" (15.2 cm)  
diameter elbow  
6" (15.2 cm)  
diameter wall cap  
SIDE DUCTING IN TOE KICK TO OUTSIDE  
THROUGH FLOOR BETWEEN JOISTS TO OUTSIDE  
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing  
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.  
JRC120012A 07/2012  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Washer IWC 61251 User Manual
JBL Portable Speaker MR25 User Manual
John Lewis Oven JLBIOS601 User Manual
JVC Projector DLA G10E User Manual
Karcher Vacuum Cleaner NT 65 2 ECO User Manual
Kenwood Stereo System M 707I User Manual
Kidde Smoke Alarm 0913 User Manual
Klipsch Portable Speaker Sattelite Speaker User Manual
Kodak Digital Camera C503 User Manual
Konica Minolta All in One Printer C30P User Manual