www.dexpres s .com
Fax on Demand (775) 8 33-36 0 0
This Data Sheet Includes Information On
36"
Jenn-Air
Product Model Number (s):
•
•
36" Gas Cooktops:
JGC8536ADB, JGC8536ADW, JGC8536ADQ and
JGC8536ADS
3 13/16"
21 9/16"
Side View (not to scale)
•
Dimensions (Actual Size)
Overall width: 36"
•
Overall Dimensions
Top View (not to scale)
Overall depth: 21 9/16"
Distance from top of counter to bottom of unit: 3 13/16"
Cut-Out width: 34 7/8"
Cut-Out Dimensions
Countertop View
(not to scale)
Cut-Out depth: 20 13/16"
20 13/16"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the RIGHT: 8"
34 7/8"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the LEFT: 8"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the REAR: 3/4"
Minimum spacing to front edge of counter: 2"
Minimum distance between cooktop
30" min
and cabinet directly above:
Cabinet Requirements
Wall View
Minimum width of cabinet directly above: 36"
Maximum depth of cabinets directly
(not to scale)
13"
above and adjacent:
36"
30" min
Minimum distance between countertop
Minimum horizontal
clearance between the
edge of the appliance
and combustible
construction extending
from the cooking
surface to 18" above
the cooking surface is
8" (see solid areas)
and adjacent cabinet above: 18"
•
Additional Information
•
18"
• Distance from top of counter to bottom of gas stub is
4 9/16".
• Distance from top of counter including manifold
entrance is 7 1/2.
• Electrical requirements : 110/120 volt AC, 60hz. Must
be grounded. 15amp circuit required. Locate outlet
below the cooktop a minimum of 5" below the
countertop if not installing over an under counter oven.
Locate outlet below the oven or in an adjacent cabinet
when installing over an adjacent under counter oven.
• Minimum clearance from top of counter to combustible
material below is 4 7/16"
• Countertop must be supported within 3" of cutout.
• Unit may be installed over a Jenn-Air under counter
oven.
Top view of cutout
(not to scale)
1 3/4" to centerline of pipe from
back edge of cutout
Gas inlet location
See page 2 for additional information
1 3/4" from left side
of cutout to
centerline of pipe.
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of deter-
mining actual damages, liability of Dimension Express shall
not exceed $50.00.
Cooktop supplied with 1/2" NPT female inlet on regulator
Copyright © Dimension Express, 2003.
321
• NEVER reuse Data Sheets. Data Sheets are subject to change without
notice. Dimension Express is a FREE service bureau and is updated daily,
it makes far more sense to spend the time necessary to request new Data
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
• Call Dimension Express if you have any questions at (775) 833-3633 •
• Always refer to a current Code at a Glance or manufacturer directory •
• Data Sheet codes change on the first of odd numbered months at 12:01am •
BN182.34 • A321B149 • • 031111 • 115727 • 89750