Chromatherapy Light Kit
instaLLation and operation instruCtions
The Jacuzzi Chromatherapy Lamp provides beautiful and
pLanning instaLLation
practical illumination to your bath. It includes vivid rotating colors
or penetrating white lighting to enhance your Jacuzzi experience,
and is built to give years of service and pleasure.
It is necessary to plan the location of the control box, control
panel, and each lamp before drilling any holes. A possible
configuration of the Chromatherapy equipment is shown in
Figure 1.
The Lamp can be installed on most Jacuzzi baths or on any
bath having sufficient flat space on the bath shell. The basic kit
consists of an electrical control box and one Chromatherapy
Lamp, with all necessary modular cables. The control box can
support up to four lamps. An additional lamp kit is available and
provides one lamp and one cable.
First, consider the location requirements for the control panel and
lamp(s), see Figure 2. The control panel cannot be immersed
in the bath water. Therefore it must be positioned at least one
inch above the level of the overflow drain. On the other hand,
the lamp(s) must be positioned a minimum of 4 inches below the
normal water line.
The installation requires drilling a hole in the bath shell for the
control panel and each lamp. The Installation and Operation
Instructions will provide all the information required for planning
the installation, completing the installation, and complete
operation of the equipment. The control box must be installed
meeting applicable local building and electrical codes on a stud
beam or wall.
Control panel
Lamp 1
Lamp 2
Contents
Basic Lamp Kit . . . . . . . . . . . . . . . . . . . . . . 1
Planning Installation . . . . . . . . . . . . . . . . . . . 1
Control Panel . . . . . . . . . . . . . . . . . . . . . 2
Chromatherapy Lamp . . . . . . . . . . . . . . . . 2
Mount the Control Box . . . . . . . . . . . . . . . . . . 3
Drill the Holes . . . . . . . . . . . . . . . . . . . . . . 3
Drill Hole for Control Panel . . . . . . . . . . . . . . 3
Drill Hole for Lamp(s) . . . . . . . . . . . . . . . . . 3
Install Panel and Lamp(s) . . . . . . . . . . . . . . . . 4
Mount Control Panel . . . . . . . . . . . . . . . . . 4
Mount Chromatherapy Lamp(s) . . . . . . . . . . . 4
Leak Test . . . . . . . . . . . . . . . . . . . . . . . . 5
Operate Chromatherapy Lighting . . . . . . . . . . . . 5
Use Chromatherapy Lighting . . . . . . . . . . . . . 5
Control Chromatherapy Lighting . . . . . . . . . . . 5
Control Color Lighting . . . . . . . . . . . . . . . 5
Control White Lighting . . . . . . . . . . . . . . 5
Figure 1. Possible configuation for Chromatherapy assembly
Top rim of bath
Hole for control panel
1 inch
Overflow drain
Normal water line
BasiC Lamp Kits
GD56000 Complete kit
One control box for wall mounting
One control panel and one control cable (RJ-45 plug)
One lamp and one lamp cable (RJ-11 plug)
4 inches (minimum)
GQ88000 Accessory lamp kit
One lamp and one lamp cable (RJ-11 plug)
Hole for lamp(s)
To add an additional lamp, up to four total, order the accessory
lamp kit. It includes one lamp and one lamp cable. Each lamp
is mounted in the same manner, and is connected to the control
box as described. To order additional lamps, please contact your
Jacuzzi dealer or agent.
Floor of bath
important: Read the instructions before beginning the
installation.
Figure 2. Locate the Holes for Control Panel and Lens(es)
Copyright © 2008 by Jacuzzi Whirlpool Bath Products
GQ99000 • 07-08
Download from Www.Somanuals.com. All Manuals Search And Download.
No. 10 Screw hole
(2 both sides)
mount the ControL Box
Mount the control box to a stud beam or secure wall using four
No. 10 screws, or four No. 20, 1/4 inch screws. The mounting
holes for the screws are shown in Figure 5.
No. 20, 1/4”
Screw hole
(2 both sides)
note: The modular plugs are also shown in the figure. Position
the control box in the most advantageous way, considering the
length and direction of the modular cables.
Caution: The power cable must be connected to a dedicated
ground fault circuit interruptor (GFCI). No other outlet is
acceptable to this equipment.
Attach the control box securely to the mounting location.
driLL the hoLes
Modular plug
for control panel
Modular plugs
for lamps (1 to 4)
3-Prong power cable
After preparation of the bath shell for drilling the hole for the
control panel and each Chromatherapy lamp, proceed with drilling
the holes. This should be completed by a technican experienced
in drilling through a fine acrylic material.
Figure 5. Control Box Connections
The areas of the holes have been covered with masking tape and
carefully outlined to indicate the location and size of the holes.
The tape will help prevent chipping of the acrylic.
Drill Hole for the Control Panel
The control panel has been located a minimum of one inch
above the level of the overflow drain. It has been marked for a
1-1/16 inch diameter with a 5/32 inch notch at the right center, see
Figure 3.
Caution: Drill the holes from the inside of the unit carefully
to prevent chipping or cracking of the acrylic shell. Use a drill
guide for best results and begin drilling at low speed until the
drill penetrates the acrylic layer, then use a high speed for the
remaining material.
1.
2.
First use a 5/32 inch drill bit to carefully drill the notch.
Use the 5/32 inch drill bit to drill a pilot hole for the
1-5/8 inch hole.
3.
4.
Use a 1-1/16 inch drill bit to complete the hole for the lamp.
Remove any and all burrs or roughness from the inside of
the hole.
Drill Hole for the Lamp(s)
The lamp(s) has been located a minimum of 4 inches below the
normal water level. It has been marked for a 1-5/8 inch diameter,
see Figure 4.
Caution: Drill the holes from the inside of the unit carefully
to prevent chipping or cracking of the acrylic shell. Use a drill
guide for best results and begin drilling at low speed until the
drill penetrates the acrylic layer, then use a high speed for the
remaining material.
1.
Use the 5/32 inch drill bit to drill a pilot hole for the 1-1/16
inch hole.
2.
Use a 1-5/8 inch drill bit to complete the hole for the control
panel.
Jacuzzi© Chromatherapy: Installation and Operation
Page ꢀ of 5
GQ99000 • 07-08
Download from Www.Somanuals.com. All Manuals Search And Download.
3.
Remove any and all burrs or roughness from the inside of
the hole.
Apply silicone
behind panel
Clean away all debris and tools from the area. Use a moist cotton
cloth to wipe the inside and shelf of the bath rim.
Modular
cable
INSTALL PANEL AND LAMP(S)
Install the control panel and each lamp as described below.
Control
panel
Hole for control panel
(see detail below)
Mount Control Panel
The hole for the control panel has a notch to ensure proper
mounting alignment of the control panel on the bath, see Figure 6.
Figure 6. Mount the Control Panel
1.
Apply clear silicone to the back side of the control panel and
insert the panel into place.
Caution: Do not permit silicone to enter the plug area at the
back of the panel. Failure to comply may result in damage to the
equipment.
Bath shell (Outisde of bath)
2.
Press the panel fast against the inside surface of the bath.
Make sure the panel is pressed completely against the
shell.
3.
Remove excess silicone from around the control panel.
Chromatherapy
lamp or control
panel (Inside of
bath)
4.
Alow the silicone to cure to ten to fifteen minutes
undisturbed.
Plug from control
panel or lamp
5.
Attach the control cable from the control panel to the control
box, see Figure 7. The proper plug for the control panel is
shown in Figure 5.
Mount Chromatherapy Lamp(s)
The hole is ready to mount the lamp(s), see Figure 8.
Figure 7. Attach plug to Chromatherapy device
1.
Remove the retainer nut from the lamp assembly.
2.
Apply clear silicone around the back of the edge of the
lamp.
Apply silicone
behind panel
Hole,
1-1/16”
Retainer
nut
Caution: Do not permit silicone to enter the plug area at the
back of the lamp. Failure to comply may result in damage to the
equipment.
3.
Insert the lamp housing through the hole in the bath shell
so that the edge of the lamp housing is tightly against the
inside surface of the bath. Make sure the lamp is pressed
completely against the shell to prevent leakage.
Inside surface
of bath shell
4.
From the outside of the bath shell, screw the retainer nut
over the threaded body, as shown in the figure. Hand-
tighten the retainer nut onto the lens threads. Do not permit
the lamp to rotate while tightening the retainer nut.
Lamp
assembly
Figure 8. Hole for Chromatherapy Lamp(s)
5.
6.
7.
Remove any excess silicone from around the lamp.
Allow the silicone to cure for ten to fifteen minutes.
Attach the light cable from the back of the lamp to the
control box see Figure 7. The proper plug for the lamp(s) is
shown in Figure 5.
note: There are four plugs for up to four lamp cables. Any of the
four plugs can be used for proper operation. Jacuzzi recommends
that you start with the left-most plug, closest to the control box
cable plug to attach each lamp.
Jacuzzi© Chromatherapy: Installation and Operation
Page ꢁ of 5
GQ99000 • 07-08
Download from Www.Somanuals.com. All Manuals Search And Download.
LeaK test
Allow the silicone to cure for 24 hours before performing the Leak
Test. Fill the bath with water and check for leakage at the lamp
location(s).
operate Chromatherapy Lighting
The Chromatherapy Control Panel is located for easy access
while using the bath, see Figure 8. It is controlled by a three-
button panel. The three button panel controls the Light Switch
(center button), and two arrow keys (the Up Arrow and the Down
Arrow), see Figure 9.
Figure 9. Chromatherapy Control Panel
Use Chromatherapy Lighting
1. Press the Control Panel Light Switch to initiate the
Chromatherapy Lighting. The color that shines is the last
color that was on when the Chromatherapy Lighting was
turned off (Programmed Color).
2. Press the Light Switch again to initiate the simple White
Lighting.
3. Press the Light Switch a third time to turn off the
Chromatherapy Lighting.
Control Chromatherapy Lighting
The use of the arrow keys provides beautiful and useful options
for the lighting.
ControL CoLor Lighting
When you initiate the Chromatherapy Lighting, the Programmed
Color will shine. Use the Up Arrow to initiate cycling through the
colors. The scrolling through the wonderful colors indeed provides
a "chromatherapeutic" effect.
note: The color cycle is: Orange, red, pink, violet, blue, green,
yellow, and orange again. (If you use the Down Arrow, the color
cycling will follow the reverse order through the colors.)
If you want to stop at a particular color, simply use the Up Arrow
again to stop the cycling.
ControL White Lighting
In the White Lighting setting there are two positions for a brighter
light, controlled by the Up Arrow; and two positions for the dimmer
light, using the Down Arrow.
Jacuzzi© Chromatherapy: Installation and Operation
Page 5 of 5
GQ99000 • 07-08
Download from Www.Somanuals.com. All Manuals Search And Download.
|