TM
ProTech LCD Series Owner’s Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 FCC Notice......................................................................................1
3.2 Hyperthermia....................................................................................................4
3.3 Cautions..............................................................................................................4
4.0 Choosing A Location....................................................................6
4.1 Outdoor Location............................................................................................6
5.0 Power Requirements....................................................................7
6.0 Electrical Wiring Instructions ....................................................9
7.0 Start-Up Instructions..................................................................11
7.1 Filling The Spa................................................................................................11
7.2 Safety Check...................................................................................................11
7.3 Turn on Power.................................................................................................11
7.4 Initiating Water Circulation........................................................................11
7.5 Adding Start-Up Chemicals......................................................................12
7.6 Place Cover on Spa.....................................................................................12
8.1 Control Panel ..................................................................................................12
8.2 LCD Display.....................................................................................................13
8.3 Spa Features And Controls.......................................................................14
9.0 Operating Instructions...............................................................15
9.1 Set Spa to Heat.............................................................................................15
9.2 View....................................................................................................................15
9.3 Light ...................................................................................................................15
9.4 Activate Pump 1...........................................................................................16
9.5 Activate Pump 2/Pump 3........................................................................16
9.7 Adjusting Individual Jet Flow...................................................................17
9.8 Adjusting PowerPro Jets............................................................................17
9.9 Waterfall Feature...........................................................................................17
9.10 Air Controls......................................................................................................17
9.11 Optional Jacuzzi Premium Audio System...........................................17
Download from Www.Somanuals.com. All Manuals Search And Download.
10.0 Automatic Filtration Cycles .....................................................26
10.1 Standard Filtration Mode ..........................................................................26
10.2 Economy Filtration Mode..........................................................................26
10.3 Selecting The Filtration Mode.................................................................26
10.4 Preset Filter Cycles.......................................................................................27
10.5 Clean-Up Cycles............................................................................................27
11.1 Adjusting Time of Day................................................................................28
11.2 Changing Filter Cycles ...............................................................................28
11.4 Locking Filter Cycles...................................................................................30
11.5 Panel Lock.......................................................................................................30
11.6 Temperature Setting Lock.........................................................................30
12.0 Spa Maintenance .......................................................................30
12.1 Cleaning The Filters.....................................................................................31
12.2 Draining and Refilling.................................................................................32
12.3 Cleaning The Spa Interior.........................................................................33
12.4 Pillow Care ......................................................................................................33
12.5 Maintaining The Cover...............................................................................34
12.6 Maintaining The Wood Cabinet.............................................................34
12.7 Winterizing ......................................................................................................34
13.0 Water Quality Maintenance ....................................................36
13.1 pH Control.......................................................................................................36
13.3 Optional CD Ozone Water Maintenance System............................37
13.4 Summer Logic................................................................................................37
18.0 Wiring Diagram (50Hz J-350/J-360/J-370 Models).........44
19.0 Wiring Diagram (50Hz J-380 Model) ...................................45
20.0 Typical Spa Wiring Diagrams A-B (60Hz Models).............46
Download from Www.Somanuals.com. All Manuals Search And Download.
1.0 Important Spa Owner Information
Your Jacuzzi® Premium spa is constructed to the highest standards and is
capable of providing many years of trouble-free use. However, because heat
retentive materials are utilized to insulate the spa for efficient operation, an
uncovered spa surface directly exposed to sunlight and high temperatures for
an extended period is subject to permanent damage. Damage caused by
exposing the spa to this abuse is not covered by warranty. We recommend
that you always keep the spa full of water when it is exposed to direct sun-
light and that you keep the Jacuzzi Premium insulating cover in place at all
times when the spa is not in use. Read and carefully follow the requirements
for your spa’s support base found in section 4.0 titled, “Choosing a Location”
(Page 6).
Jacuzzi Premium constantly strives to offer the finest spas available, therefore
modifications and enhancements may be made which affect the specifica-
tions, illustrations and/or instructions contained herein.
2.0 FCC Notice
This equipment has been tested and found to comply with the limits
for a Class B Digital Device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful inter-
ference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the inter-
ference by one or more of the following measures:
1. Rearrange or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver
3. Connect the equipment into an outlet on a circuit different from the
circuit connected.
4. Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for
FCC compliance could void the user’s authority to operate this equipment.
Page 1
Download from Www.Somanuals.com. All Manuals Search And Download.
3.0 IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety pre-
cautions should always be followed, including:
1. READ AND FOLLOW ALL INSTRUCTIONS BEFORE OPERATING THE
SPA!
2. WARNING: To reduce the risk of injury, do not permit children to use this
product unless they are closely supervised at all times.
3. WARNING: A grounding wire connector is provided on this unit to con-
nect a minimum No. 8 AWG (8.4mm2) solid copper conductor between
this unit and any metal equipment, metal enclosures of electrical equip-
ment, metal water pipe, or conduit within 5 feet (1.5m) of the unit.
4. DANGER: Risk of Accidental Drowning. Extreme caution must be exer-
cised to prevent unauthorized access by children. To avoid accidents,
ensure that children cannot use this spa unless they are supervised at all
times.
5. DANGER: Risk of Injury. The suction fittings in this spa are sized to match
the specific water flow created by the pump. Should the need arise to
replace the suction fittings or the pump, be sure that the flow rates are
compatible. Never operate the spa if the suction fittings are broken or
missing. Never replace a suction fitting with one rated less than the flow
rate marked on the original suction fitting.
6. DANGER: Risk of Electric Shock. Install at least 5 feet (1.5m) from all metal
surfaces. As an alternative, a spa may be installed within 5 feet of metal
surfaces if each metal surface is permanently connected (bonded) by a
minimum No. 8 AWG (8.4mm2) solid copper conductor attached to the
wire connector on the grounding lug, inside the equipment compartment
on the equipment box.
7. DANGER: Risk of Electric Shock. Do not permit any electrical appliance,
such as a light, telephone, radio, television, etc. within 5 feet (1.5m) of a
spa, unless such appliances are built-in by the manufacturer.
8. ELECTRICAL SUPPLY: The electrical supply for this product must include
a suitably rated switch or circuit breaker to open all ungrounded supply
conductors to comply with section 422-20 of the National Electrical Code,
ANSI/NFPA 70. The disconnect must be readily accessible and visible to
the spa occupant but installed at least 5 feet (1.5m) from the spa water.
9. WARNING: To Reduce the Risk of Injury:
A. The water in a spa should never exceed 104 °F (40 °C). Water tempera-
tures between 100 °F (38 °C) and 104 °F (40°C) are considered safe for
a healthy adult. Lower water temperatures are recommended for young
children and when spa use exceeds 10 minutes.
Page 2
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Since excessive water temperatures have a high potential for causing fetal
damage during the early months of pregnancy, pregnant or possibly preg-
nant women should limit spa water temperatures to 100 °F (38 °C). If
pregnant, please consult your physician before using a spa.
C. Before entering the spa, the user should measure the water temperature
with an accurate thermometer since the tolerance of water temperature-
regulating devices may vary as much as 5 °F ( 2 °C).
D. The use of alcohol, drugs, or medication before or during spa use may
lead to unconsciousness with the possibility of drowning. Persons using
medication should consult a physician before using a spa since some
medication may induce drowsiness, while other medication may affect
heart rate, blood pressure, and circulation.
E. Persons suffering from obesity or a medical history of heart disease, low
or high blood pressure, circulatory system problems, or diabetes should
consult a physician before using a spa.
3.1 IMPORTANT CSA SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions
should always be followed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. A green colored terminal or a terminal marked G, Gr, Ground, Grounding
or the
symbol* is located inside the supply terminal box or compart-
ment. To reduce the risk of electric shock, this terminal must be con-
nected to the grounding means provided in the electric supply service
panel with a continuous copper wire equivalent in size to the circuit
conductors that supply this equipment (*IEC Publication 417, Symbol
5019).
3. At least two lugs marked “Bonding Lugs” are provided on the external
surface or on the inside of the supply terminal box/compartment. To
reduce the risk of electric shock, connect the local common bonding grid
in the area of the spa to these terminals with an insulated or bare
copper conductor not smaller than No. 6 AWG (10mm2).
4. All field-installed metal components such as rails, ladders, drains or other
similar hardware within 10 feet (3m) of the spa shall be bonded to
the equipment grounding buss with copper conductors not smaller than
No. 6 AWG (10mm2).
5. Save These Instructions:
A. WARNING: Children should not use spas without adult supervision.
B. WARNING: Do not use spas unless all suction guards are installed to
prevent body and hair entrapment.
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
C. WARNING: People with infectious diseases should not use a spa.
D. WARNING: To avoid injury, exercise care when entering or exiting the
spa.
E. WARNING: Do not use drugs or alcohol before or during the use of a
spa to avoid unconsciousness and possible drowning.
F. WARNING: Pregnant or possibly pregnant women should consult a
physician before using a spa.
G. WARNING: Water temperature in excess of 38 °C (104 °F) may be
injurious to your health.
H. WARNING: Before entering the spa, measure the water temperature
with an accurate thermometer.
I. WARNING: Do not use a spa immediately following strenuous exercise.
J. WARNING: Prolonged immersion in a spa may be injurious to your
health.
K. WARNING: Do not permit electric appliances (such as light, telephone,
radio, television, etc.) within 5 feet (1.5m) of this spa unless factory
installed.
L. CAUTION: Maintain water chemistry in accordance with manufacturer’s
instructions.
M. WARNING: The use of alcohol or drugs can greatly increase the risk of
fatal hyperthermia in spas.
3.2 HYPERTHERMIA
Prolonged immersion in hot water may induce hyperthermia. A description of
the causes, symptoms, and effects of hyperthermia are as follows:
Hyperthermia occurs when the internal temperature of the body reaches a
level several degrees above the normal body temperature of 98.6 °F (37 °C).
The symptoms of hyperthermia include drowsiness, lethargy, and an increase
in the internal temperature of the body. The effects of hyperthermia include:
A Unawareness of impending hazard;
B. Failure to perceive heat;
C. Failure to recognize the need to exit spa;
D. Physical inability to exit spa;
E. Fetal damage in pregnant women; and
F. Unconsciousness and danger of drowning.
3.3 CAUTIONS
1. Persons suffering from heart disease, diabetes, high or low blood pres-
sure, and any condition requiring medical treatment, pregnant women,
the elderly, or infants should consult with a physician before using a spa.
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
2. The Consumer Products Safety Commission has stated that the water
temperature in a spa should not exceed 104 °F (40 °C). Immersion in
water in excess of 104 °F (40 °C) can be hazardous to your health.
3. Observe a reasonable time limit when using the spa. Long exposures at
higher temperatures can cause high body temperature. Symptoms may
include dizziness, nausea, fainting, drowsiness, and reduced awareness.
These effects could possibly result in drowning.
4. Do not use the spa under the influence of alcohol, narcotics, or other
drugs. Use of the spa under these conditions may lead to serious conse-
quences.
5. Always test the spa water temperature before entering the spa. Enter and
exit the spa slowly. Wet surfaces can be very slippery.
6. Never bring any electrical appliances into or near the spa. Never operate
any electrical appliances from inside the spa or when you are wet unless
such appliances are built-in by the manufacturer.
7. Proper chemical maintenance of spa water is necessary to maintain
safe water and prevent possible damage to spa components.
8. Use the straps and clip tie downs to secure the cover when not in use.
This will help to discourage unsupervised children from entering the spa
and keep the spa cover secure in high-wind conditions. There is no rep-
resentation that the cover, clip tie-downs, or actual locks will prevent
access to the spa.
3.4 GENERAL ELECTRICAL SAFETY INSTRUCTIONS
Your new Jacuzzi Premium spa is equipped with a "state-of-the-art" equip-
ment system. It contains the most advanced safety and self-protective equip-
ment in the industry. Nonetheless, this spa must be installed properly to
insure dependable usage. Please contact your dealer or local building
department should you have any questions regarding your installation.
Proper grounding is extremely important. Jacuzzi Premium spas are
equipped with a current collector system. A pressure wire connector is pro-
vided on the surface of the control box, located outside the equipment door
(Figure B, Page 10) to permit connection of a bonding wire between this
point and any ground metal equipment, metal water pipe or conduit within
5 feet (1.5m) of the spa, or copper clad grounding rod buried within 5 feet
(1.5m) of the spa. Bonding wire must be at least No. 8 AWG (8.4mm2)
solid copper wire. This is a most important safety assurance feature. Before
installing this spa, check with the local building department to insure instal-
lation conforms to local building codes.
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 Choosing A Location
IMPORTANT: Because of the combined weight of the spa, water and
users, it is extremely important that the base upon which the spa
rests be smooth, flat, level and capable of uniformly supporting this
weight, without shifting or settling, for the entire time the spa is in place. If
the spa is placed on a surface which does not meet these requirements, dam-
age to the skirt and/or the spa shell may result. Damage caused by improp-
er support is not covered under warranty. It is the responsibility of the spa
owner to assure the integrity of the support at all times.
We recommend a poured, reinforced concrete slab with a minimum thickness
of 4 inches (10cm). Wood decking is also acceptable provided it is con-
structed so that it meets the requirements outlined above. The spa must be
installed in such a manner as to provide drainage away from the spa. Placing
the spa in a depression without provisions for proper drainage could allow
rain, overflow and other casual water to flood the equipment and create a wet
condition in which it would sit. For spas which will be recessed into a floor or
deck, install so as to permit access to the equipment, either from above or
below, for servicing. Make certain that there are no obstructions which would
prevent removal of the cabinet side panels and access to the jets components,
especially on the side with the equipment bay doors.
4.1 Outdoor Location
In selecting the ideal outdoor location for your spa, we suggest that you take
into consideration:
1. The proximity to changing area and shelter (especially in colder weather).
2. The pathway to and from your spa (this should be free of debris so that
dirt and leaves are not easily tracked into the spa).
3. The closeness to trees and shrubbery (remember that leaves and birds
could create extra work in keeping the spa clean).
4. A sheltered environment (less wind and weather exposure can result in
lowered operation and maintenance costs).
5. The overall enhancement of your environment. It is preferable not to place
the spa under an unguttered roof overhang since run-off water will
shorten the life expectancy of the spa cover.
4.2 Indoor Location
For indoor installations, be certain to make provisions for proper ventilation.
When the spa is in use, considerable amounts of moisture will escape. This
can damage certain surfaces over time. If you have any questions regarding
the placement or installation of your spa, consult your authorized Jacuzzi
Premium dealer.
Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
5.0 Power Requirements
Jacuzzi Premium spas are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service as listed
in the tables below. If you prefer, your Jacuzzi Premium dealer can perform
a minor circuit board modification to allow the spa to accept different electri-
cal service. The operational considerations of these modifications are listed in
the footnotes below.
US/Canada J-350/J-360/J-370 Models (60Hz)
240V/50A*
240 VAC
3
240V/60A** 240V/30A***
Voltage:
Number of Wires:
Frequency:
240 VAC
3
240 VAC
3
60Hz
60Hz
60Hz
Current Draw:
Circuit Breaker:
36A
50A, 2-Pole
43A
60A, 2-Pole
24A
30A, 2-Pole
Important Information:
*
In 50A configuration, the heater will not operate while both jets
are running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
** In 60A configuration, the heater will operate while both jets pumps
are running in high speed. Note jets pump 2 runs only in high
speed.
*** In 30A configuration, the heater will not operate while either jets
pump is running in high speed. Note: jets pump 2 runs only in high
speed.
US/Canada J-380 Models (60Hz)
240V/60A*
240 VAC
3
240V/50A** 240V/40A***
Voltage:
Number of Wires:
Frequency:
240 VAC
3
240 VAC
3
60Hz
60Hz
60Hz
Current Draw:
Circuit Breaker:
46A
60A, 2-Pole
36A
50A, 2-Pole
31A
40A, 2-Pole
Important Information:
*
In 60A configuration, the heater will operate while any two jets
pumps are running in high speed. This is the factory setting.
** In 50A configuration, the heater will not operate while any two jets
pumps are running in high speed. Note: jet pumps 2&3 run only in
high speed.
*** In 40A configuration, the heater will not operate while any jets
pump is running in high speed. Note: jet pumps 2&3 runs only in
high speed.
Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Export J-350/J-360/J-370 Models (50Hz)
230V/40A* 230V/30A** 230V/20A***
Voltage:
Number of Wires
Frequency:
Current Draw:
Circuit Breaker:
230 VAC
3
50Hz
29A
230 VAC
3
50Hz
23A
230 VAC
3
50Hz
15A
40A
30A
20A
Important Information:
*
In 40A configuration, the heater will operate while both jets pumps
are running in high speed. This is the factory setting.
** In 30A configuration, the heater will not operate when both jets
pumps are running in high speed. Note jets pump 2 runs only in
high speed.
*** In 20A configuration, the heater will not operate while either jets
pump is running in high speed. Note: jets pump 2 runs only in high
speed.
All export models can be adapted to use higher amperage circuits when
available. Please contact your dealer for details. The electrical supply for
this product must comply with local electrical regulations.
Export J-380 Models (50Hz)
230V/40A* 230V/35A**
Voltage:
Number of Wires
Frequency:
Current Draw:
Circuit Breaker:
230 VAC
3
50Hz
32A
230 VAC
3
50Hz
26A
40A
35A
Important Information:
*
In 40A configuration, the heater will operate while any two jets
pumps are running in high speed. Note: jet pumps 2&3 run only in
high speed. This is the factory setting.
** In 35A configuration, the heater will not operate while any two jets
pumps are running in high speed. Note: jet pumps 2&3 run only in
high speed.
All export models can be adapted to use higher amperage circuits when
available. Please contact your dealer for details. The electrical supply for
this product must comply with local electrical regulations.
Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
6.0 Electrical Wiring Instructions
IMPORTANT NOTICE: The electrical wiring of this spa must meet
the requirements of the National Electrical Code (NEC) and any
applicable state or local codes. The electrical circuit must be
installed by a qualified electrician and approved by a local build-
ing/electrical inspection authority.
1. This spa must be permanently connected (hard-wired) to the power
supply. No plug-in connections or extension cords are to be used in
conjunction with the operation of this spa. Supplying power to
the spa which is not in accordance with these instructions will void
both the independent testing agency listing and the manufacturer’s
warranty.
2. The power supplied to this spa must be a dedicated circuit with no
other appliances or lights sharing the power provided by the circuit.
3. To determine the current and voltage and wire size required, refer to
section 5.0 “Power Requirements” (Page 7).
• Wire size must be appropriate per NEC and/or local codes.
• We recommend type THHN wire.
• All wiring must be copper to ensure proper connections. Do not use
aluminum wire.
• When using wire larger than #6 (10mm2), add a junction box near the
spa and reduce to short lengths of #6 (10mm2) wire to connect to spa.
4. The electrical supply for this product must include a suitably rated switch
or circuit breaker to open all ungrounded supply conductors to comply
with Section 422-20 of the National Electrical Code, ANSI/NFPA 70. The
disconnecting means must be readily accessible to the spa’s occupant
but installed at least 5 feet (1.5m) from spa water.
5. The electrical circuit supplied for the spa must include a suitable
ground fault circuit interruptor (GFCI) as required by NEC Article 680-42.
6. To gain access to the spa’s power terminal block, remove the screws
securing the panel under the controls. Then remove the four control box
door screws and door (Figure B, Page 10).
7. Select the power supply inlet you want to use (Figure A, Page 10) and
remove the short cabinet panel from the front of the spa to allow you to
feed the cable through to the control box. Install the cable with connec-
tor through the large opening provided in the bottom of the control box.
8. Connect wires, color to color, on terminal blocks TB1 and TB3 (Figures
C-D, Page 10). TIGHTEN SECURELY! All wires must be hooked up secure-
ly or damage could result.
9. Install control box door and screws and reinstall the cabinet side panels.
Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure-A
Equipment Area
Note: Pump Locations Vary by Model
9
4
10
1
Flow
7
3
5
6
6
2
2
Circulation Pump
Behind Load Box
8
1. Control Box
7. 1-Speed Pump #2
8. Circulation Pump
9. Optional CD Ozonator (Purchased Separately)
10.Optional Mazzei Injector (Required for CD Ozonator
Use - Purchased Separately)
2. Power Supply Entrance(s)
3. 2-Speed Pump #1
4. Heater
5. Spa Drain Valve
6. Pump Drain Plug(s)
Figure-B - Control Box
2
TB1
1
1. Terminal Block
2. Bonding Lug
3. Grounding Terminal
3
RED
RED
BLUE
BLUE
Figure-C
TB1
TB1
Figure-D
RED
1
1
2
BLK
BLK
BROWN
BROWN
BLK
2
to Circuit
Board
to Circuit
Board
Green
Green
PowerIn
PwoerIn
TB3
TB3
All Export J-350 / J-360 / J-370 / J-380
Models: 230 VAC, 3-Wire (50Hz)
US/Canada J-350 / J-360 / J-370 / J-380
Models: 240 VAC, 3-Wire Connection (60Hz)
Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
7.0 Start-Up Instructions
Congratulations! You are now all set to get your new spa ready to use. Simply
follow this step-by-step procedure and, before long, you will be enjoying your
first glorious experience in your Jacuzzi Premium spa. For best results, read
each step in its entirety before proceeding with that step.
7.1Filling the Spa
Clear all debris from the spa. Although the spa shell has been polished at
the factory, you may want to treat it with a specially formulated spa cleaner
and wax available from your dealer prior to filling the first time.
Remove the filter cover, then remove both filter cartridges as outlined in
section 12.1 (Page 31). Place the end of your garden hose into the exposed
pump #1 filter wall fitting without a mesh grill. Fill the spa half way, then
place end of your garden hose into the circulation pump filter wall fitting
with the mesh grill. Continue filling spa until the water level is 1 inch below
the lowest pillow and and above all jets. Do not over fill. Never fill with
water from a water softener.
If your water is extremely “hard”, it is preferable to fill half-way with hard
water and the rest of the way with softened water. Or, you may fill entirely
with hard water if you use a special water additive available from your
Jacuzzi Premium dealer. Always refill spa through both filter wall fittings
to purge trapped air from pump intakes. Failure to do so may cause air to
be trapped in either pump #1 or the circulation pump’s intake (air lock),
preventing either pump from circulating water. After filling, make sure
both filters are installed properly before applying power to the spa. Refer
to section 12.1 (Page 31) “Cleaning the Filter” for specific cleaning
and installation instructions.
7.2 Safety Check
Open the wood cabinet access panel and check all pump unions to make sure
they are hand tight. Loosening can occur during shipping and handling.
7.3 Turn on Power
Turn on power to spa at the home’s circuit breaker. The heater and circulation
pump will automatically activate. If the control panel LCD flashes water tem-
perature and “COOL” or “ICE”, the pump 1 will also activate in low speed. If
this occurs, refer to page 38-39 for additional information.
7.4 Initiating Water Circulation
Depress the JETS 1 sensor pad on the control panel twice to
activate pump #1 in high speed and initiate maximum water
flow to certain jets.
Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
7.5 Add Start-Up Chemicals
Add the spa water chemicals as recommended by your Jacuzzi Premium
Dealer. Refer to section 13.0 (Page 36) for general guidance.
7.6 Place Cover On Spa
Keeping the insulating cover in place anytime the spa is not in use will
reduce the time required for heating, thereby minimizing operating costs.
The time required for initial heat-up will vary depending on the starting water
temperature and the capacity of your spa. Smaller spas heat at a rate of
approximately 8 to 10 degrees per hour; larger spas heat at about 4 to 6
degrees per hour.
WARNING: RISK OF INJURY. Always check water temperature
carefully before entering spa.
8.0 Control Functions
8.1 Control Panel
E
D
A. Select Sensor Pad: filter
cycle programming
features.
C
B
I
A
B. Cycle Sensor Pad:
accesses filter cycle
program mode and next
cycle.
C. Mode Sensor Pad:
switches between
H
G
F
*Display shown for example purposes only, actual water temperature
display will vary
standard and economy filtration modes (Page 26).
D. Display Sensor Pad: displays time of day and initiates time setting
and locking functions.
E. Invert Sensor Pad: inverts the main 4-digit LCD display.
F. Warmer + / Cooler - Sensor Pads: these sensors display and
increase or decrease the temperature setting. They also display
other programmable features.
G. Light Sensor Pad: controls the spa light (Page 15).
H. JETS 1 Sensor Pad: controls the 2-speed pump #1 (Low, High, Off).
I. JETS 2 Sensor Pad: controls jet pumps 2&3 as follows:
• In J-350/J-360/J-370 Models: controls high-speed pump #2 (On, Off).
• In J-380 Models: controls high-speed pump 2&3 (On, Off)
Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
8.2 LCD Display
A
B
C
D
E
I
F
G
H
A. Lock Symbol indicates panel, set temperature, or filter cycle
programming is locked.
B. Heat Symbol: indicates heater is on (Sec. 9.1, Page 15).
C. Ozone Symbol indicates the optional CD Ozonator is on Sec. 13.3,
Page 37).
D. General Indicators: show which filter cycle is in progress or display
selected filter cycle programming features (Sec. 11.2, Page 28).
E. Set Indicators: these characters identify what is being shown on
the main 4-digit display.
F. Light Symbol: indicates spa light is on.
G. JETS 1 Symbol indicates 2-speed pump #1 is on. The symbol
changes according to speed selected and flashes during an
automatic operation.
H. JETS 2 Symbol indicates the following:
• On J-350, J-360, J-370 models, this symbol indicates high-speed
pump #2 is on.
• On J-380 models, this symbol indicates either high-speed pump
#2 and/or pump #3 are on.
I. Mode Annunciators: these characters identify which filtration mode
is currently selected (Page 26).
Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
8.3 Spa Features And Controls
J-370 model illustrated - Location of Features Varies by Model
1. Control Panel
11. Vertical Jets (Foot Jets)
2. Air Controls
12. Footwell Suction Fittings and
Filters. Filters protect pump 2
(and J-380 pump 3) plumbing
network from debris buildup.
13. Waterfall Feature
14. Mini PowerPro Jets (Calf Jets)
15. Micro PowerPro Jets (Wrist Jets)
16. Heater Return Fitting
3. Filter/Skimmer Cover
4. Diverter Valve #2
5. Maxx PowerPro Jets
6. PowerPro Jets/Mini-
PowerPro Jets
7. Diverter Valve #1
8. Remote Control Panel
9. Therapy Seat
17. Optional Audio System Speakers
18. Optional Audio System Receiver
10. Spa Light
Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
9.0 Operating Instructions
Your Jacuzzi Premium spa has a touch-sensitive control panel, diverter valves,
and air control knobs located on the top rim of the spa (Page 14). These con-
trols let you operate many of the special functions of your Jacuzzi Premium
spa. By familiarizing yourself with the following information, you will be able
to gain the full benefit afforded by the various functions of your spa.
9.1 Set Spa To Heat
To warm spa water, follow these steps:
1. The LCD display on the control panel displays the actual
temperature of the spa water. Press either the WARMER
( + ) or COOLER ( - ) sensor pad once to display the “set
temperature” for 5 seconds. If you want the water to heat
to a different temperature, simply press WARMER ( + ) or COOLER ( - )
within 5 seconds. The set temperature advances or decreases by one
degree each time one of these sensor pads is pressed.
2. The heater will turn off when the temperature corresponding to the
thermostat setting is achieved.
Important Heater Details:
• The maximum temperature for which the spa can be set is 104 °F
(40 °C) and the minimum is 80 °F (27 °C).
• If spa is powered by the minimum required amp service (Page 7-8)
turn off all high speed pumps to operate heater. Note: jets Pump 2
and J-380 Pump 3 run only in high speed.
• Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
• The heater operates until the water reaches the programmed “set
temperature”, then turns off. The heater will reactivate after the
water cools to approximately 1.5° below the “set temperature.”
9.2 View
Pressing this sensor pad inverts the main four-digit display on
the command center’s LCD screen to allow easy reading from
either inside or outside the spa.
9.3 Light
The spa light offers 6 constant color variations and a unique
random mode for enhanced spa enjoyment. Press the LIGHT
sensor pad once to turn the spa light on in “Random” mode,
Page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
then repeatedly press the sensor pad to turn the light off or to select one of
6 constant colors illustrated below.
RANDOM
OFF
RED
OFF
GREEN
OFF
BLUE
OFF
ORANGE
Spa Light Sequence
OFF
TEAL
OFF
VIOLET
OFF
You must press the LIGHT sensor pad within 5 seconds between each “off”
or “color” step in the light sequence to prevent it from resetting. Pressing
the sensor pad after 5 seconds restarts the sequence at “Random” mode.
This mode automatically changes the light color every 8 to 20 seconds.
Note: Any time the spa light is manually turned on, it will automatically turn
off after approximately 1 hour. If you desire more light at this time, simply
turn the light back on.
9.4 Activate Pump 1
The sensor pad labeled JETS 1 controls the 2-speed pump #1.
Pressing this sensor cycles pump #1 from off, to low speed, to
high speed, and back to off.
9.5 Activate Pump 2/Pump 3
On two pump J-350, J-360, J-370 models, the sensor pad
labeled JETS 2 controls the high-speed pump #2. Pressing this
sensor cycles pump #2 on and off.
On the three pump J-380 model, this sensor pad controls both pump #2 and
pump #3 in the following sequence:
A) Press once to turn on pump #2 in high-speed;
B) Press a second time to turn on pump #3 in high-speed;
C) Press a third time to turn off pump 2;
D) Press a fourth time to turn off pump #3.
Auto Turn Off — Anytime a pump has been manually turned on, it will
automatically turn off after approximately 20 minutes. If at this time you
desire more jet operation you may simply turn the pump(s) back on.
9.6 Selecting Desired Massage Action
Your Jacuzzi Premium spa is equipped to allow you to customize the massage
action you desire. Each model incorporates a diverter valve that allow you to
Page 16
Download from Www.Somanuals.com. All Manuals Search And Download.
customize the massage and performance by diverting water
between various jet systems. Simply turn diverter to position
A (Combo), B, or C to divert water pressure to various jet
groups. Note: The diverter valve(s) is designed to operate in
positions A (Combo), B, and C for optimum performance. It
B
C
A
is considered normal for sound levels within the valve to vary between posi-
tions due to the large amounts of water flowing through it! For optimum fil-
tration benefits, leave the valve in position A when spa is covered. Select
position B or C for maximum jet performance during spa use.
9.7 Adjusting Individual Jet Flow
The water flow to the individual jets in your spa
can be increased or decreased by rotating the outside
jet face (Except Maxx PowerPro Jets). Note: Always
keep at least 6 adjustable jets open at all times.
9.8 Adjusting PowerPro Jets
With the nozzles of the PowerPro Jets positioned straight
ahead, the jet stream will be stationary. Pushing the nozzle to
one side causes the jet nozzle to rotate, moving the jet stream
in a circular pattern.
9.9 Waterfall Feature
The waterfall feature allows you to independently control it for a customized
soothing effect. The JETS 1 button activates the waterfall feature. Then,
each fall is individually adjusted moving the control lever next to it forward or
backwards. To turn on, move lever inward. To turn off, move lever outward.
9.10 Air Controls
Certain jet systems have their own “push-button” air control.
Each control introduces air into the water lines that supply that
specific jet group. Simply press any air control button (once) to
open; then press a second time to close. To minimize heat loss,
all air controls should be closed when the spa is not in use.
9.11 Optional Jacuzzi Premium Audio System
Spas equipped with the optional Jacuzzi Premium Stereo
System offer enhanced spa enjoyment. These models include
an integrated AM/FM/CD receiver with two high-quality
marine speakers for unsurpassed sound quality and long-life.
Both speakers located on spa corners (Sec. 8.3, page 14) are designed for
manual exposure and retraction. To expose each speaker for audio, squeeze
Page 17
Download from Www.Somanuals.com. All Manuals Search And Download.
the latch tabs together at the top of each speaker enclosure to unlatch it’s
“pop-up” mechanism. To retract each speaker before covering spa, gently
press downward on each enclosure until you feel a slight “click”, then
release.
CAUTION: Never step or sit on a speaker enclosure! This type of misuse
will damage the speaker enclosure latching and track mechanism. Always
retract speakers prior to covering spa.
Optional Stereo Receiver - Basic Operation
VOL
VOL
LOUD
DISP
W1 1
W3 3
W2 2
RPT 4
JENSEN
Open
ST
AS/PS
W/B
CH
BAND
SEL/
PWR
SHF 5
SCN 6
8 x OVERSAMPLING
•
4 X 40 WATTS
MCD-9424RC
A. On/Off
PWR
Press red PWR button once to turn stereo on.
Press a second time to turn off.
B. Select Mode
VOL
Press blue SEL button to select
volume, treble, bass, balance,
and fader functions as shown.
SEL/
SEL/
(Volume)
Use blue VOL
or VOL
(Treble)
(Fader)
buttons to adjust selected
mode. Note: when mode
has not been adjusted for
3-seconds, display returns to
standard radio or CD display.
SEL/
SEL/
(Balance)
(Bass)
SEL/
C. Volume
VOL
Press blue VOL
or VOL
button to adjust
VOL
VOL
volume to desired listening level.
Page 18
Download from Www.Somanuals.com. All Manuals Search And Download.
SEL/
SEL/
D. Adjust Treble
Press blue SEL button two times to
select treble mode. Then press blue
VOL or VOL button to adjust treble
range from -7 to +7.
VOL
VOL
E. Adjust Bass
SEL/
SEL/
SEL/
Press blue SEL button three
times to select bass mode. Then press
blue VOL
or VOL
button to adjust bass range from
-7 to +7.
VOL
VOL
F. Adjust Balance
Press blue SEL button four times to
select balance mode. Then press
SEL/
SEL/
SEL/
SEL/
blue VOL
or VOL
button to
adjust speaker balance as desired.
VOL
VOL
G. Adjust Fader
SEL/
SEL/
SEL/
SEL/
SEL/
Press blue SEL button five times
to select balance mode. Then
press blue VOL
or VOL
button to adjust speaker balance
as desired. Note: F15 = Front
Speakers Only; R15 = Rear
Speakers Only.
VOL
VOL
Page 19
Download from Www.Somanuals.com. All Manuals Search And Download.
H. Bass Boost
Press grey LOUD button to increase the bass output.
LOUD appears on the display.
LOUD
I. Set Clock
DISP
Press and hold grey DISP button
for 3-seconds until time display
flashes. Within 3 seconds, press blue
+ or - button to set displayed hours
and minutes. Unit stores clock settings and
returns to normal operation 3-seconds after last
key press.
Optional Stereo Receiver -
Weather Band and Radio Operation
A. Select a Weather Band
The stereo receiver has a three channel
W/B
NOAA Weather Radio receiver. NOAA
Weather Radio broadcasts National
Weather Service warnings, watches, fore-
W1 1
casts, and other hazard information 24-
hours a day.
W2 2
Press the grey WB button to change radio to
weather radio receiver. Then press green
W1, W2, or W3 to change between three
W3 3
weather channels in your area.
Page 20
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Select a Radio Station
BAND
1. Slow Scan:
Press blue + button or
- button for less than
one second to advance
radio frequency up or
down one step.
2. Quick Scan: Press blue +
button or - button for more than one second to quickly scan radio
frequencies. Frequencies continue to change until button is released.
W1 1
W3 3
W2 2
C. Program a Station Preset
Six numbered green PRESET buttons (1-6)
store and recall stations for each radio band.
RPT 4
SHF 5
SCN 6
BAND
Save a Station Preset:
1. Press grey BAND button to select desired
radio band, if necessary.
2. Select radio station by pressing
blue + button or - buttons.
W3 3
3. Press green PRESET button for
3-seconds until receiver beeps, then
release. Radio station is now stored
in memory.
ST
CH
Radio
Band
Station
Preset
Number
Page 21
Download from Www.Somanuals.com. All Manuals Search And Download.
BAND
W3 3
D. Recall a Station Preset
1. Press grey BAND button to select
desired radio band, if necessary.
2. Press green PRESET button to
recall station preset.
ST
CH
E. Automatically Store Stations
Function selects 6 strongest stations and stores them in
current band.
1. Press grey BAND button to select desired radio
band, if necessary.
2. Press grey AS/PS button for more than
3-seconds (receiver beeps and flashes AST
on display). The new stations replace station
presets previously stored in that band.
BAND
AS/PS
F. Prescan Stations
Scans stations stored in current band.
1. Press grey BAND button to select desired
radio band, if necessary.
2. Press grey AS/PS button for less than
3-seconds. The radio pauses for 5-seconds at
each station. Press grey AS/PS button again to
stop scanning when desired station is reached.
BAND
AS/PS
Page 22
Download from Www.Somanuals.com. All Manuals Search And Download.
Optional Stereo Receiver - CD Player Operation
A. Insert and Eject CD
1. Press orange OPEN
button on front flip-over
panel. Gently push a CD
into slot and flip panel up
to close. The CD will
begin to play.
OPEN
X
Insert
2. Press orange OPEN
button on front flip-over
panel, then flip-open
EJECT CD
panel. Press black EJECT
button on inner side of flip-open panel to stop CD play and eject CD.
Receiver switches to radio operation. Flip panel up to close.
B. Skip Tracks
Press blue + button or - button to advance to
next track. Track numbers show on display.
C. Fast Forward and Fast Reverse
Press and hold blue + button or - button to
fast forward or fast reverse CD. CD play
starts from when you release the button.
D. Repeat the Same Track
RPT 4
Press green RPT button to continuously repeat
same track. Press again to stop repeat.
Page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
E. Shuffle Play All Tracks
SHF 5
Press green SHF button to play all tracks on CD
in random order one time. Press again to stop
shuffle play.
F. Scan (Preview) All Tracks
Press green SCN button to play first ten seconds of
each track on current CD. SCAN appears on display.
Press green SCN button again to stop SCAN and
listen to track.
SCN 6
G. Pause CD Play
Press grey PLAY/PAUSE button to pause CD play.
PAUS appears on display. Press grey PLAY/PAUSE
button again to resume play.
WARNING!
A. Avoid splashing water directly on unit. Unit is
not waterproof!
B. Never insert CD into player while wet!
C. Inserting wet CD into player will damage unit!
D. Never operate unit without rubberized face
shield installed! Shield protects electronics
from moisture damage! Operating unit without
rubberized face shield may void factory warranty!
Page 24
Download from Www.Somanuals.com. All Manuals Search And Download.
Optional Stereo Receiver Specifications
CD Player
Signal/noise ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>86 dB
Frequency response . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Hz - 20 kHz
Channel separation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>65 dB
D/A converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Bit/CH
Weather Radio
Tuning Range . . . . . . . . . . . . . . . . . . . . . . . . .NOAA weather channels
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162.400, 162.475, 162.550
FM Tuner
Tuning range . . . . . . . . . . . . . . . . . . . . . . . . . . .87.5 MHz - 107.9 MHz
FM mono sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 dBf
50 dB quieting sensitivity (stereo) . . . . . . . . . . . . . . . . . . . . . . .16 dBf
Stereo separation @ 1 kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 dBf
Am Tuner
Tuning Range . . . . . . . . . . . . . . . . . . . . . . . . . . . .530 kHz - 1720 kHz
Amplifier
Total system power . . . . . . . . . . . . . . . . . . . . . . . . . . .160 watts peak
Power output . . . . . . . . . . . . . . . . . . . .front: 2 x 40W; rear: 2 x 40W
General
Power supply . . . . . . . . . . . . . . . . . . . . .11 - 16 VDC, negative ground
Speaker output impedance . . . . . . . . . . . . . . . . . . . . . . . . . .4-8 Ohms
Fuses . . . . . . . . . . . . . . . . . . . .fast blow AGC (0.5 Amp and 10 Amp)
Dimensions . . . . . . . . . . . .7” x 7” x 2” (178 mm x 178 mm x 51 mm)
Specifications subject to change without notice.
Page 25
Download from Www.Somanuals.com. All Manuals Search And Download.
10.0 Automatic Filtration Cycles
Your Jacuzzi Premium controls have been designed to provide maximum
convenience, as well as economy of operation. By selecting the appropriate
filtration mode, you can ensure that your spa will be ready to use
anytime with the lowest possible energy consumption.
Your spa’s control system activates automatic filter cycles, during which
pump #1 turns on in low speed to move water through the filter. This water
movement also provides important skimming action to remove debris and
suspensions from the water’s surface, minimizing the “bathtub ring” effect.
10.1 Standard Filtration Mode
In standard mode, water temperature is held to the set temperature by the
24-hour circulation pump and heater which turns on as needed to maintain
the set temperature. After the set temperature is reached, the heater turns
off and the circulation pump continues to operate continuously to filter and
clean the spa water, unless programmed otherwise (Sec. 11.3, Page 29).
10.2 Economy Filtration Mode
In economy mode, water temperature is not thermostatically controlled. The
low speed pump #1 and heater turn on only during a programmed filter
cycle. Note: you can change pump #1 to high speed or turn it off during a
filter cycle, however, it will automatically revert back to low speed in 20 min-
utes for the duration of the filter cycle.
10.3 Selecting the Filtration Mode
Press the MODE button to select either “Standard” or “Economy” mode.
The control panel’s annunciator on the right side of the LCD changes to
indicate which mode is selected.
When an automatic filter cycle activates, the LCD screen displays the
following message:
FILTER
CYCLE
ON
Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Summer Logic: In warm weather, the water temperature in the spa may
exceed the set temperature. This condition may occur due to heat trans-
ference from the main pump and 24-hour circulation pump. If the water
temperature is higher than 95°F (35°C) and rises two degrees above the
set temperature, a “Summer Logic” condition occurs that deactivates the
circulation pump and ozonator (if equipped). This safety feature can-
not be altered! The circulation pump and ozonator will remain off until
the water temperature cools to the set temperature (except
between12AM-2AM when the circulation pump runs for it’s mandatory
2-hour “clean-up” cycle). To help prevent a “Summer Logic” condition,
it may be necessary to reduce filter cycle and/or circulation pump run
times in warm weather.
10.4 Preset Filter Cycles
Your spa comes with four 30-minute filter cycles already programmed in,
beginning at 6:00 a.m., noon, 6:00 p.m. and midnight. You can easily
change the start time, or the cycle length for any of these cycles to suit
your individual needs by following the steps in the next sections.
10.5 Clean-Up Cycle
The clean-up cycle is once per day in both Standard and Economy mode at
12:00 PM for two minutes. This is not user programmable. Pump #2 (and
J-380 Pump #3) activate for one minute to circulate any water in the
plumbing. After 1 minute pump #2 (and J-380 Pump #3) turn off and
pump #1 continues to run for 1 minute. If the filter cycle is also set at
12:00 PM, pump 1 will continue to run for the duration of the filter cycle.
Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
11.0 Programming Instructions
11.1 Adjusting Time of Day
The control system remembers the time of day even in the event of a
prolonged power outage. However, it may occasionally be necessary to reset
the time of day. For example: if you are not in the Pacific Time Zone you will
want to reset the time for your own time zone. (The system will automatical-
ly adjust to and from daylight savings time.) To accomplish this, press DIS-
PLAY, MODE and DISPLAY within five seconds each. A number represent-
ing the hour will be displayed, followed by AM or PM. The hour will advance
or decrease each time WARMER ( + ) or COOLER ( - ) is pressed within five
seconds. Then, press DISPLAY again to display the minutes. Adjust the min-
utes as necessary by pressing WARMER ( + ) or COOLER ( - ) After 5 sec-
onds, the display will return to normal.
11.2 Changing Filter Cycles
The control system allows you to easily adjust two separate aspects of each
of the filtration cycles: 1) the time of day at which each cycle begins; and
2) the duration of each cycle.
To make adjustments, first press CYCLE to enter the filter cycle programming
mode. The LCD screen will display the following in the upper right corner:
ADJUST
FILTER
CYCLE
START TIME
START TIME
This means the system is ready to accept your changes to the start time for
filter cycle number one. Simultaneously, the large four-digit display in the
center of the screen displays the currently programmed start time for that fil-
tration cycle.
At this point, you have four options. You may:
1. Press WARMER ( + ) or COOLER ( - ) to adjust the start time in incre-
ments of 30 minutes.
2. Press CYCLE to display and adjust each subsequent filter cycle start time.
With each press, the currently programmed status will be shown in the
large four digit display. To adjust any display value, simply press WARMER
( + ) or COOLER ( - ).
3. Press SELECT to move down the menu from Start Time to Duration.
With each press, the currently programmed duration will be shown in the
Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
large four-digit display. Press WARMER ( + ) or COOLER ( - ) to adjust
duration in increments of 15 minutes.
4. Press DISPLAY to make the filter cycle programming characters disap-
pear from the screen and the main display return to showing the water
temperature. If no sensor is pressed within 30 seconds, the screen auto-
matically returns to the standard water temperature display.
At any time, you may check the programming of any aspect of any filter cycle
by first pressing CYCLE then moving through the menu by pressing either
CYCLE or SELECT. The programming is changed only by pressing WARMER
( + ) or COOLER ( - ) during this process.
11.3 Programming Circulation Pump Run Time
The control system allows you to easily adjust two separate aspects of
circulation pump operation:
1. The time of day (start time) the circulation pump begins operating.
2. The length of time (duration) the circulation pump operates.
The factory default start time is 12:00AM (Midnight). The default duration
is 24 hours. To make adjustments, press the sensor labeled CYCLE five
times to enter the circulation pump programming mode. The LCD screen
will display ADJUST Circ. At this time the system is ready to accept your
changes.
• Press the SELECT sensor once. The previously programmed start time
appears on the LCD display.
• Press WARMER ( + ) or COOLER ( - ) sensors to adjust the start time
in 30-minute increments.
• Press the SELECT sensor to program duration.
• Press WARMER ( + ) or COOLER ( - ) sensors to program the duration
time in 2 hour increments.
• Press DISPLAY to make the circulation pump programming characters
disappear from the screen and the main display return to showing the
water temperature. If no sensor is pressed within 30 seconds, the
screen will automatically return to the normal water temperature display
Note: In standard filtration mode only, the circulation pump automatically
activates if the spa requires heat regardless of the programmed start time
and duration.
Page 29
Download from Www.Somanuals.com. All Manuals Search And Download.
11.4 Locking Filter Cycles
You may keep the filter cycle programs from being inadvertently
altered by electronically “locking” them. To accomplish this, simply
press CYCLE then, within 30 seconds, press DISPLAY, MODE and
WARMER ( + ), within five seconds each.
LOCKED
A padlock symbol will appear on the screen. In this state, the status of the
cycle programming may be checked, but may not be altered. To unlock the
filter cycle programming to make changes, simply press DISPLAY, MODE
and COOLER ( - ) within five seconds each.
11.5 Panel Lock
To help prevent unauthorized use of your spa, the Sentry controls
incorporate a unique panel locking system which disables the con-
trols on the panel.
LOCKED
To Lock The Panel: Press the DISPLAY, MODE, and WARMER ( + ) sensor
pads, in order, within five seconds. A padlock symbol will appear on the LCD
screen. With the panel locked, none of the components can be turned on
and the only settings that can be adjusted are the standard/economy oper-
ating mode and changing the time of day. All automatic spa functions will
operate normally.
To Unlock The Panel: Press DISPLAY, MODE, and COOLER ( - ), in order,
within five seconds. The “lock” symbol will disappear. All sensor pads are now
active.
11.6 Temperature Setting Lock
To electronically lock the temperature setting, first enter the “temperature set-
ting” mode by pressing WARMER ( + ) or COOLER ( - ). Then, within five
seconds, press the three sensors described under “Panel Lock” above. This
will prevent the temperature setting from being changed by unauthorized per-
sons but all other sensors will remain active.
To unlock the temperature setting so that it can be adjusted, simply follow the
instructions above under “To Unlock The Panel.”
12.0 Spa Maintenance
Proper and regular maintenance of your spa will help it retain its beauty and
performance. Your authorized Jacuzzi Premium dealer can supply you with all
Page 30
Download from Www.Somanuals.com. All Manuals Search And Download.
the information, supplies, and accessory products you will need to accomplish
this.
12.1 Cleaning The Filters
Your Jacuzzi Premium spa is equipped with high-performance filter cartridges
located inside the filter skimmer. Fine debris is filtered by the circulation pump
drawing water through the circulation pump cartridge. Larger debris is also
filtered by the 2-speed pump drawing water through the main pump cartridge
during normal operation and at each filter cycle. Both cartridges provide
unsurpassed water quality by trapping suspended particles on their outer
surface.
All models include filters on their footwell suction covers (Page 14) that
prevent debris from entering pump 2 (and J-380 pump 3), when
operating. These filters must remain in place to protect the pump 2
(and J-380 pump 3) plumbing network(s). They should be cleaned every
2 months, or when weak pump performance is observed.
To ensure optimum performance, clean and reuse both cartridges once a
month. ALWAYS TURN POWER TO SPA OFF BEFORE CLEANING THE
FILTER CARTRIDGES! Refer to the filter cleaning/replacement procedure
below:
TURN POWER TO SPA OFF!
A
B
C
D
filter cover
handles
handle
(Inside Spa View)
(Inside Spa View)
Skimmer Well
Lift upward on filter cover handles to
unsnap and remove it from mating
retainer clips.
Rotate each filter cartridge handle
counterclockwise to unthread from
mating wall fitting.
Remove both cartridges from
skimmer well.
Page 31
Download from Www.Somanuals.com. All Manuals Search And Download.
E
F
G
top
top
Cartridge 1
Cartridge 2
(Inside Spa View)
(Inside Spa View)
Rinse debris from filter pleats on
each cartridge using a garden hose
and high-pressure nozzle. Start at
top and work downward to handle.
Repeat until all pleats are clean.
Place each cartridge back into
1. Install filter cover by sliding it
down into position over mating
retainer clips.
skimmer well , then rotate each
*
cartridge handle clockwise to
thread back into wall fitting. DO
NOT OVERTIGHTEN!
2. Turn power to spa back on.
Note: to maximize filter life, switch filter cartridge positions at each cleaning. The circulation pump's filter wall
fitting is easily identified by it's mesh grill.
*
Periodically, both filter cartridges will need a more thorough cleaning to
remove imbedded oils and minerals. For this, we suggest cleaning as illus-
trated above (Step E), followed by soaking the filter overnight in a plastic con-
tainer filled with a solution of water and a specially formulated filter cleanser
available from your Jacuzzi Premium dealer. We also recommend switching
your two filter cartridges during each cleaning to maximize life. The average
life expectancy of each filter cartridges is approximately two years with prop-
er care, rotation, and water quality maintenance. Replacement cartridges may
be purchased from your Jacuzzi Premium dealer.
12.2 Draining and Refilling
About every 3 to 6 months, you will want to replace the spa’s water. The fre-
quency depends on a number of variables including the amount of use, atten-
tion paid to water quality maintenance, etc. You will know it is time for a
change when you cannot control sudsing and/or you can no longer get the
normal feel or sparkle to the water even though the key water balance mea-
surements are all within the proper parameters.
WARNING! READ THIS BEFORE DRAINING: To prevent damage
to the spa’s components, turn off power to the spa at the circuit
breaker before draining it. Do not turn the power back on until
your spa has been refilled.
Page 32
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION: There are certain precautions to keep in mind when
draining your spa. If it is extremely cold, and the spa is outdoors,
freezing could occur in the lines or the equipment (see “WINTERIZ-
ING”, page 34). On the other hand, if it is hot outdoors, do not leave
the spa’s surface exposed to direct sunlight.
To drain your spa, perform the following steps:
1. Turn off power to spa at breaker.
1. Turn off power to spa.
2. Locate drain valve on front/lower plastic pan.
Hold larger (rear) body to prevent it from
2.
turning, then loosen and remove the front
cap to expose underlying male hose threads.
3. Attach garden hose to exposed threads.
3.
4. Gently rotate larger (rear) valve body 1/3 turn
counterclockwise to unlock drain valve.
5. Pull larger (rear) body outward to open drain.
6. After spa drains, perform steps 2-5 in reverse
Unlock
Drain
4.
5.
order to close drain prior to refilling spa.
After refilling, turn on power to the spa and
follow the steps listed under “Start-Up
Instructions.” Always fill your spa through
both filter wall fittings (page 11).
Open Drain
12.3 Cleaning The Spa Interior
To preserve the sheen of your spa's surface, it is crucial that you avoid
using abrasive cleaners or cleaners which have adverse chemical effect on the
surface. If you are not certain as to the suitability of a particular cleanser, con-
sult your authorized Jacuzzi Premium dealer.
Regardless of the cleanser used, use extreme care to assure that no soap residue
is left on the surface. This could cause severe sudsing when the spa is refilled.
Your Jacuzzi Premium dealer offers a specially formulated surface sealant which
aids in cleaning the spa surface and adds a protective coating to enhance the
luster of the surface.
12.4 Pillow Care
Remove and clean the headrest pillows as needed with soapy water using a cloth or
soft-bristle brush. To maintain water resistance and luster, apply a quality vinyl condi-
tioner once a month. Always remove the pillows when adding chemical shock treat-
ment to the spa water. The pillows can be returned to the spa when the sanitizer
reading drops below 5 ppm.
Page 33
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION: Never attempt to remove the pillows by pulling on them! The
pillows utilize a bolt-on design that prohibits removal without tools.
To remove pillows:
1. Grasp center pillow insert (A) with
finger tips and gently pry outward from
pillow base (C).
2. Use a standard screwdriver to loosen
and remove mounting bolts (B) from
pillow base.
3. Assemble in reverse order after
cleaning. DO NOT overtighten
pillow mounting bolts!
12.5 Maintaining the Cover
Using the Jacuzzi Premium insulating spa cover anytime the spa is not in use will
significantly reduce your operating costs, heat-up time and maintenance require-
ments. To prolong the life of the cover, handle it with care and clean it regularly
using mild soap and water. Periodic treatments with a special conditioner developed
for Jacuzzi Premium spa covers will help protect against deterioration caused by UV
rays from the sun. Never allow anyone to stand or sit on the cover, and avoid drag-
ging it across rough surfaces.
12.6 Maintaining The Wood Cabinet
With time and exposure to the elements, the wood on your spa will tend to lose its
new appearance. Protecting or reviving the wood surfaces is a fairly simple process.
Light sanding with fine-grit sandpaper will help smooth any roughness and regular
applications of a penetrating wood preservative will enhance and protect the rich-
ness of the wood. A specially formulated wood stain available from your Jacuzzi
Premium dealer is ideal for this.
NOTE: Do not apply varnish, shellac or other surface sealants to the
wood. These tend to react with the chemicals in the wood and the UV
rays of the sun, causing yellowing, flaking and peeling.
12.7 Winterizing
Your Jacuzzi Premium spa is designed to automatically protect itself against
freezing when operating properly. During periods of severe freezing tempera-
tures, you should check periodically to be certain that the electrical supply to
Page 34
Download from Www.Somanuals.com. All Manuals Search And Download.
the spa has not been interrupted. In extreme, bitter cold weather less than
-20 °F (-29 °C), reset the filter cycles for 24-hour operation to protect the spa
(i.e. four 6-hour cycles).
If you do not intend to use your spa, or if there is a prolonged power outage
during periods of severe freezing temperatures, it is important that all water
be removed from the spa and equipment to protect against damage from
freezing.
For expert winterization of your spa, contact your authorized Jacuzzi
Premium dealer. In emergency situations, damage can be minimized by tak-
ing the following steps:
1. Follow the directions on page 32 for draining the spa.
2. As the water level drops below the seats, use whatever means
necessary to get the water out of the recessed seating areas and into
the footwell.
3. When the water level ceases to drop, use whatever means available to
remove any remaining water from the footwell.
4. Turn off power to the spa.
5. Remove the equipment-side cabinet panels and locate the drain plugs
in the front of the pump(s) (Figure-A, Page 10). Remove these plugs to
allow the water to drain out of the pumps and heater. Note:
Approximately one to two gallons will be released during this
procedure. Use a wet/dry vacuum or other means to keep this from
flooding the equipment compartment. Replace the drain plugs.
6. Loosen hose clamp at bottom of heater behind the control box (Figure-
A, Page 10) and pull hose off of heater fitting (twist the hose back
and forth while pulling downward). Tip hose down and allow to drain,
then reinstall hose and clamp.
7. Re-install cabinet side panels and cover spa so that no casual moisture
can enter into it.
Consult your Authorized Jacuzzi Premium dealer if you have any questions
regarding winter use or winterizing.
12.8 Restarting Your Spa in Cold Weather
If you want to start up your spa after it has sat empty for a time in freezing
temperatures, be aware that the water remaining in certain sections of the
piping may still be frozen. This situation will block water flow preventing the
spa from operating properly and possibly damaging the equipment. We rec-
ommend you consult your dealer for guidance before attempting to re-start
your spa under these conditions.
Page 35
Download from Www.Somanuals.com. All Manuals Search And Download.
13.0 Water Quality Maintenance
Maintaining the quality of the water within specified limits will serve to
enhance your enjoyment and prolong the life of the spa's equipment. It is a
fairly simple task, but it requires regular attention because the water chemistry
involved is a balance of several factors. There is no simple formula, and there
is no avoiding it. A careless attitude in regard to water maintenance will result
in poor and potentially unhealthful conditions for soaking and even damage
to your spa. For specific guidance on maintaining water quality, consult your
Authorized Jacuzzi Premium dealer who can recommend appropriate chemi-
cal products for sanitizing and maintaining your spa.
CAUTION: Never store spa chemicals inside the spa's equipment bay.
13.1 pH Control
pH is a measure of relative acidity or alkalinity of water and is measured on a
scale of 0 to 14. The midpoint of 7 is said to be neutral, above which is alka-
line and below which is acidic. In spa water, IT IS VERY IMPORTANT TO
MAINTAIN A SLIGHTLY ALKALINE CONDITION OF 7.2 to 7.8. Problems
become proportionately severe the further outside of this range the water
gets. A low pH will be corrosive to metals in the spa equipment. A high pH
will cause minerals to deposit on the interior surface (scaling). In addition, the
ability of the sanitation agents to keep the spa clean is severely affected as
the pH moves beyond the ideal range. That is why almost all spa water test
kits contain a measure for pH as well as sanitizer.
13.2 Sanitizing
To destroy bacteria and organic compounds in the spa water, a sanitizer
must be used regularly. Chlorine and Bromine are the two most popular
sanitizers used to date. Many other additives are available for your spa.
Some are necessary to compensate for out-of-balance water, some aid in
cosmetic water treatment and others simply alter the feel or smell of the
water. Your Authorized Jacuzzi Premium dealer can advise you on the use of
these additives.
CAUTION: Do not use chlorine tablets (Trichlor) in your spa. This chemical
can have an extremely corrosive effect on certain materials in the spa.
Damage caused by use of this chemical, or improper use of any chemicals,
is not covered under the spa's warranty.
Page 36
Download from Www.Somanuals.com. All Manuals Search And Download.
13.3 Optional CD Ozone Water Maintenance System
If you have elected to have your spa equipped with the optional Jacuzzi
Premium CD Ozone water purification system you will find that your water
stays fresh and clear with significantly less chemical sanitizer usage. You will
also probably be able to go longer between complete spa drainings. The
CD ozone unit operates in conjunction with the circulation pump.
13.4 Summer Logic
When the actual spa water temperature reaches up to 2 °F
(1 °C) above the set temperature, the spa goes into “sum-
mer logic.” The circulation pump will turn off automatically
to avoid adding additional heat to the water, eventually cre-
ating an overheat condition. This setting is not user-pro-
grammable.
Note: The summer logic does not take effect until the spa water tempera-
ture reaches 95 °F (35 °C). This condition is more likely in excessively hot
weather. Remember, the spa’s ability to cool is directly affected by the
ambient temperature. An excessively hot ambient temperature may prevent
the spa from cooling down because it’s fully insulated construction is
designed to retain heat and to minimize operating costs.
14.0 Troubleshooting - Display Messages
There are a number of unique functions designed into your Jacuzzi Premium
spa to protect it from damage and/or to aid in troubleshooting. Following is
a listing of all the possible messages along with their meanings:
MESSAGE
MEANING
Overheat Protection (Heater is deactivated, pump’s
low speed is activated). Water temperature is
above acceptable limits. Do not enter the water!
When the actual water temperature is approxi-
mately 2 °F (1 °C) above the set temperature, the
circulation pump will stop operating to reduce
(frictional) heating. Remove spa cover to speed
cooling (CAUTION! Never leave spa uncovered
when children are present!) See “WATER IS
TOO HOT” on page 41. If condition persists,
contact your authorized Jacuzzi Premium dealer.
Page 37
Download from Www.Somanuals.com. All Manuals Search And Download.
If the spa water is more than 20 °F (-7 °C) cooler
than the temperature setpoint, the low speed
pump #1 and heater will automatically activate to
provide freeze protection. The spa will stay in this
mode until the water temperature reaches 15 °F
(-9 °C) below the set temperature. No corrective
action is necessary.
FLOW SWITCH (Heater is deactivated. Pump may
also be deactivated). Proper flow of water is inhibit-
ed or a flow switch has malfunctioned. Check for
proper water level and for a clogged circulation
pump filter cartridge (Sec. 12.1, Page 31). Contact
your dealer or service center.
*
*NOTE: THIS MESSAGE CAN ALSO APPEAR IF THE PUMP HAS NOT
REGAINED PRIME AFTER THE SPA HAS BEEN DRAINED AND
REFILLED. IF YOU SUSPECT THAT THIS IS THE CASE, SEE THE
INSTRUCTIONS ON PAGE 40 UNDER “PUMP DOES NOT OPERATE...”
Panel sensors have been pressed too many times in a
short period of time. Because this could cause exces-
sive wear on equipment components, panel sensors
are temporarily deactivated. Panel sensors will
automatically re-activate if no sensor is pressed for 30
seconds.
Circuit board temperature has exceeded acceptable
limit. This message will disappear when the circuit
board temperature drops below acceptable limit. If
condition persists, provide shade for equipment side
of spa.
FREEZE PROTECTION
A potential freeze condition has been detected. No
action is required. Pump(s) operate until the spa is out
of danger. Note: This error commonly occurs when
the spa is first filled because tap water is often very
cold.
Page 38
Download from Www.Somanuals.com. All Manuals Search And Download.
Communication between the control panel and/or
remote control panel and circuit board is faulty.
Contact your dealer or service center.
"WATCHDOG" (spa is deactivated)
A problem has been detected which could cause
damage to the spa or its components. Contact your
dealer or service center.
OPEN SENSOR (heater disabled) OR
SHORTED SENSOR (spa is deactivated)
The high-limit temperature sensor is non-functional. This
must be repaired only by a dealer or authorized service
center.
OPEN OR SHORTED SENSOR (heater disabled)
The main sensor is non-functional. This must be
repaired only by a dealer or authorized service
center.
CLOSED OR SHORTED FLOW SWITCH ON
SYSTEM STARTUP (system disabled) Flow switch
is non-functional. This must be repaired only by a
dealer or qualified service organization.
15.0 Troubleshooting - Procedures
In the unlikely event your spa is not working the way you believe it should,
please first review all installation and operating instructions in this manual and
check the message on the panel display; second, if you are still not satisfied
it is working properly, please follow the appropriate troubleshooting instruc-
tions.
PROBLEM
PROCEDURE
NONE OF THE
COMPONENTS
OPERATE (i.e.
pump, light)
Check the control panel lights.
1. If there are letters or symbols displayed on the
screen, refer to the previous section to
determine meaning and action required.
Page 39
Download from Www.Somanuals.com. All Manuals Search And Download.
2. If nothing appears on the screen:
a. Check the household circuit breaker.
b. Contact you dealer or authorized service center.
PUMP DOES
Depress "JETS" sensor.
NOT OPERATE
BUT LIGHT DOES
1. If no sound is detected or if a "buzzing" sound is
detected, turn off power to the spa and
contact your dealer or authorized service center.
2. If motor operates but no water flows to jets:
a. Pump may not be properly primed. See
instructions below.
b. Contact dealer or authorized service center.
Pump Priming Instructions: TURN SPA OFF!
Remove waterfall side filter cartridge and insert end of garden hose into
its fitting. Seal-off pipe opening around hose using a large, clean rag and
turn on maximum water flow through the hose. After about 30 seconds,
turn off water, remove hose and rag, reinstall filter and activate pump #1
on high speed. Another method of priming the spa’s pump(s) is as fol-
lows:
1. Turn off the power to the spa.
2. Remove the handle from diverter valve #1 (Sec, 8.3, Page 14)
3. Loosen the diverter valve cap slightly (counterclockwise), listening for
the air to seep out.
4. Tighten the cap finger-tight, replace the diverter valve handle, and turn
the spa’s power back on.
Note: This method must be used for the single speed pump(s) in all spas
because pump #2 (and J-380 pump #3) are not connected to the filter.
CAUTION: If freezing conditions exist and pump is not opera-
tional, take measures to protect the system from freeze damage.
See “Winterizing” (Page 34).
POOR JET ACTION
1. Make certain the pump is on high speed.
2. Check position of diverter valve
3. Open air control for selected jet system.
4. Check for adequate water level.
5. Check for dirty filter cartridge.
6. Check for dirty filters on both pump #2
footwell suction covers (Page 14).
Page 40
Download from Www.Somanuals.com. All Manuals Search And Download.
footwell suction covers (Page 14).
WATER IS TOO HOT.
NO HEAT
1. Reduce thermostat setting.
2. Reduce filtration cycle length. Even with heater
off, water temperature can increase from pro-
longed pump operation (Page 28).
1. Check thermostat setting.
2. Keep the cover in place while heating.
3. Verify which filtration mode is selected, stan-
dard or economy (Page 26).
4. If “heater on” indicator is lit, but no tempera-
ture rise is experienced after a reasonable peri-
od of time, contact your dealer or authorized
service center.
Should checking the above steps fail to correct the problem, please call your
dealer so that he may arrange service.
Jacuzzi Premium builds the best spas in the industry. Nonetheless, we are
always striving to improve the quality and features of our products. Your input
as a Jacuzzi Premium spa owner is a cherished part of this process. If you
have any comments or suggestions, or if you wish to be informed on any new
products for your spa, please write to us.
CONGRATULATIONS on your good taste and welcome to the happiest and
most relaxed family in the world!
Page 41
Download from Www.Somanuals.com. All Manuals Search And Download.
20.0 Typical Spa Wiring Diagrams A-B
US/Canada 60Hz Models Only
2-Pole Circuit Breaker with 2-Wire Grounded Load Connection
A
(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)
240 VAC
White (N)
Bonding Lug
Black (L1)
Red (L2)
2-Pole
TB1
GFCI
Breaker
Red (L2)
Black (L1)
Main
Service
Panel
with
Green
GFCI
Ground Lug
No Load Neutral Wire
Note: service disconnect not
shown in this diagram.
The control box TB1 terminal
position varies between models.
Pigtail
Neutral Bus
Ground
Main Panel with Secondary GFCI Shut-Off Box Using a
2-Pole GFCI Breaker with 2-Wire Grounded Connection
(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)
B
Main Panel*
Bonding Lug
GFCI Sub Panel*
Red (L2)
TB1
2-Pole
GFCI
Black (L1)
Breaker
Red (L2)
Black (L1)
240 VAC
Ground Lug
Green
White (N)
Green (Ground)
No Load Neutral Wire
Pigtail
Neutral Bus
Ground
Note: service disconnect not
shown in this diagram.
The control box TB1 terminal
position varies between models.
*GFCI Sub Panel commonly
used when recommended GFCI
does not install in Main Panel.
D.A.L. 07/01/2002
Page 46
Download from Www.Somanuals.com. All Manuals Search And Download.
.
Download from Www.Somanuals.com. All Manuals Search And Download.
.
Download from Www.Somanuals.com. All Manuals Search And Download.
.
Download from Www.Somanuals.com. All Manuals Search And Download.
Jacuzzi® Premium
14525 Monte Vista Ave. • Chino, CA 91710
6530-224, Rev. C
© 2002 Jacuzzi Premium
Printed in U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
|