		 Scaltrol Option   
					Installation Sheet   
					1 . 8 8 8 . 8 0 0 . 5 6 7 2   
					w w w . j a c k s o n m s c . c o m   
					Out to dishmachine   
					Item Description   
					Qty   
					Part Number   
					Scaltrol mounting   
					bracket   
					1 
					2 
					3 
					4 
					5 
					Scaltrol Unit   
					1 
					1 
					3 
					1 
					1 
					4730-003-05-76   
					Buy Locally   
					Buy Locally   
					4730-212-05-00   
					Buy Locally   
					3/4” NPT Ball Valve   
					3/4” NPT Close Nipple   
					3/4” NPT Union   
					3/4” NPT Check Valve   
					2 
					5 
					4 
					Note: The Scaltrol (item 1) ships with the check valve (item 5). All of the   
					others items shown are for a suggested installation. Installations must com-   
					ply with all applicable regulatory, health and building codes. It is the respon-   
					sibility of the installer to ensure that requirements are met. It is also the   
					responsibility of the installer to ensure that plumbing is properly supported.   
					3 
					Unit Mounting Instructions:   
					1. The Scaltrol is to be securely mounted to a wall or piece of equipment   
					using the attached mounting bracket. It must be installed so that the car-   
					tidge is pointing towards the floor. The Scaltrol unit will not operate correctly   
					otherwise. Ensure that whatever the unit is mounted to is able to support the   
					weight of the Scaltrol.   
					From system potable   
					water supply.   
					2. The unit should be mounted with a shut-off valve (as shown with item 2).   
					This will allow for easy cartidge replacement.   
					3. The check valve should be mounted with the direction arrow pointing   
					away from the Scaltrol.   
					1 
					4. Connect to dishmachine’s incoming plumbing.   
					WARNING   
					The Scaltrol should never be installed in direct sunlight or in an area exposed to excessively cold/freezing temperatures!   
					Cartridge Replacement Instructions:   
					Replace when the level in the cartridge reaches the bottom red end cap. Use the attached wrench to unscrew the cartridge chamber and remove the   
					cartridge. Once replaced with a new one (contact your chemical specialist regarding replacement parts), screw the cartridge chamber back on and   
					tighten by hand. DO NOT USE THE SUPPLIED WRENCH TO TIGHTEN THE CARTRIDGE CHAMBER!   
					You may order a replacement cartridge using part number RSC-100. This entire kit (ScalTrol unit, check valve and this instruction sheet) can be   
					ordered using part number 6401-003-05-80.   
					Specifications:   
					1. Check valve - 3/4” NPT, brass construction with 3 lbs cracking pressure.   
					2. Scaltrol, 3/4” NPT inlet and outlet, plastic body with replaceable cartridge.   
					Specifications subject to change without notice   
					07610-002-18-72B (06/05)   