Jackson Dishwasher Chemical Sanitizing Dishmachine User Manual

CHEMICAL SANITIZING DISHMACHINE  
INSTALLATION/OPERATION & TECHNICAL  
MANUAL  
FOR JACKSON MODELS:  
Delta 5  
Delta 5 D  
Jackson WWS, INC.  
P.O. BOX 1060  
HWY. 25E  
BARBOURVILLE, KY. 40906  
PHONE (606) 523-9795  
March 8, 2013  
P/N 7610-003-37-08 (Revision D)  
FAX (606) 523-9196  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STOP!  
PARE!  
ARRET!  
CALL 1-888-800-5672 TO REGISTER THIS PRODUCT!  
FAILURE TO DO SO WILL VOID THE WARRANTY!  
LLAME AL 1-888-800-5672 PARA REGISTRAR ESTE PRODUCTO!  
AL NO HACERLO LA GARANTIA SERA ANULADA!  
S.V.P. APPELER 1-888-800-5672 POUR ENREGISTRER CE PRODUIT,  
LA GARANTIE SERA ANNULEE POUR TOUT PRODUIT NON- ENREGISTREE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REVISION/ REVISION  
MADE APPLICABLE  
DETAILS  
PAGE  
DATE  
BY  
ECN  
A
05-25-2007  
MAW  
N/A  
Release to production.  
24  
10-04-2007  
MAW  
7934  
Changed cover on power junction box.  
10  
B
05-20-2009  
04-26-2012  
ARL  
RLC  
QOF 339  
QOF 386  
Updated programming page diagram.  
Updated location of door switch on schematic.  
C
D
04-27-2012  
03-08-13  
RLC  
RLC  
QOF 386  
Added EnergyStar logo.  
QOF NDB-219 Updated company logo  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL  
Delta 5  
Delta 5 - Low temperature, chemically sanitizing, with a booster tank. Detergent, rinse aid & sanitizer  
chemical feeder pumps  
Delta 5 D - Dual door. Low temperature, chemically sanitizing, with a booster tank. detergent, rinse  
aid & sanitizer chemmical feeder pumps  
Jackson WWS, INC. provides technical support for  
all of the dishmachines detailed in this manual. We  
strongly recommend that you refer to this manual  
before making a call to our technical support staff.  
Model:  
Serial No.:  
Please have this manual with you when you call so  
that our staff can refer you, if necessary, to the prop-  
er page. Technical support is available from 8:00  
a.m. to 5:00 p.m. (EST), Monday through Friday.  
Technical support is not available on holidays.  
Contact technical support toll free at 1-888-800-  
5672. Please remember that technical support is  
available for service personnel only.  
Installation Date:  
Service Rep. Name:  
Phone No.:  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SECTION  
I.  
DESCRIPTION  
PAGE  
SPECIFICATION INFORMATION  
Specifications  
Dimensions  
2
3
II.  
INSTALLATION/OPERATION INSTRUCTIONS  
Installation Instructions  
5
Electrical Installation Instructions  
Operation Instructions  
6
7
Chemical Dispensing Equipment  
Universal Timer Operation  
Detergent Control  
9
10  
11  
III.  
IV.  
PREVENTATIVE MAINTENANCE  
13  
16  
TROUBLESHOOTING SECTION  
Common Problems  
V.  
PARTS SECTION  
Chemical Feeder Pump Assembly  
Solenoid Valve Repair Parts  
Control Box Assembly  
Peripump Box Assembly  
Electrical Connection Box Assembly  
Frame Assembly  
Hood Assembly  
Switch Panel Assembly  
Tub Assembly  
Frame & Motor Assembly  
Pump and Motor Assembly  
Booster Tank Assembly  
Incoming Plumbing Assembly  
Door Components  
18  
19  
22  
23  
24  
25  
26  
27  
29  
31  
32  
33  
34  
35  
36  
Front Panel Assembly  
VI.  
ELECTRICAL SCHEMATICS  
Delta 5 (115 Volt, 60 Hz, Single Phase)  
38  
40  
VII.  
JACKSON MAINTENANCE & REPAIR CENTERS  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1:  
SPECIFICATION INFORMATION  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1: SPECIFICATION INFORMATION  
SPECIFICATIONS OF THE DELTA 5  
F
ELECTRICAL REQUIREMENTS:  
OPERATING CAPACITY ( NSF RATED):  
WASH PUMP MOTOR HP  
3/4  
RACKS PER HOUR  
DISHES PER HOUR  
GLASSES PER HOUR  
29  
725  
725  
RINSE  
HEATER  
TYPICAL  
TOTAL ELECTRICAL  
VOLTS  
115  
PH  
1
HZ  
60  
RATINGS  
2KW@110V  
AMPS  
*16 A  
CIRCUIT  
20 AMP  
OPERATING CYCLES (SECONDS):  
NORMAL CYCLE:  
* This dishmachine is designed so that the wash motor is never  
running when the wash heater is on. Service load is based upon  
the higher of the two amperages.  
WASH TIME  
RINSE TIME  
TOTAL CYCLE TIME  
45  
25  
90  
NOTE: Typical Electrical Circuit is based upon (1) 125% of the  
full amperage load of the machine and (2) typical fixed-trip  
circuit breaker sizes as listed in the NEC 2002 Edition. Local  
codes may require more stringent protection than what is  
displayed here. Always verify with your electrical service  
contractor that your circuit protection is adequate and meets  
all applicable national and local codes. These numbers are  
provided in this manual simply for reference and may change  
without notice at any given time.  
WASH TANK CAPACITY (GALLONS):  
WASH PUMP CAPACITY (GPM):  
OPERATING TEMPERATURES:  
1.2  
61  
FRAME DIMENSIONS:  
WASH (MINIMUM)  
WASH (RECOMMENDED)  
RINSE (MINIMUM)  
(48.9°C) 120°F  
(60.0°C) 140°F  
(48.9°C) 120°F  
(60.0°C) 140°F  
WIDTH  
DEPTH  
(622.3mm)  
(641.35mm)  
(933.45mm)  
(990.6mm)  
24 1/2”  
25 1/4”  
36 3/4”  
39”  
RINSE (RECOMMENDED)  
DEPTH, WITH FRONT DOOR OPEN  
HEIGHT  
MAXIMUM WASH  
CHAMBER CLEARANCE  
WATER REQUIREMENTS:  
(292.1mm)  
11 1/2”  
WATER LINE SIZE NPT  
DRAIN LINE SIZE NPT  
FLOW PRESSURE  
1/2”  
2”  
20 5 PSI  
FRAME DIMENSION (DOUBLE DOOR):  
WIDTH  
DEPTH  
(622.3MM)  
(714.375MM) 28 1/8”  
24 1/2”  
DEPTH, WITH DOOR OPEN  
HEIGHT  
(1311.275MM)  
(990.6MM)  
51 5/8”  
39”  
MINIMUM CHLORINE REQUIRED (PPM):  
50  
CHAMBER CLEARANCE  
(292.1MM) 11 1/2”  
NOTE: Always refer to the machine data plate for specific  
electrical and water requirements. The material provided on  
this page is for reference only and may be subject to change  
without notice.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1: SPECIFICATION INFORMATION  
DIMENSIONS  
25 1/4  
(642 mm)  
A - Incoming Water Connection  
B - Drain Connection - 2" IPS  
C - Electrical Connection Point  
NOTE: All vertical dimensions are  
at lowest point due to adjustable  
bullet feet and may be raised an  
additional 2 3/4".  
24 1/2  
(622 mm)  
36 3/4  
(933 mm)  
11 1/2  
(292 mm)  
DISH  
CLEARANCE  
C
C
20  
(508 mm)  
39  
(991 mm)  
A
21 1/4  
(540 mm)  
12 1/4  
(311 mm)  
A
7 3/4  
(197 mm)  
17  
(432 mm)  
3 (76 mm)  
6 (152 mm)  
B
B
6 3/4 (171 mm)  
21 1/4  
(540 mm)  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INSTALLATION/OPERATION  
INSTRUCTIONS  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS  
INSTALLATION INSTRUCTIONS  
VISUAL INSPECTION: Before installing the unit, check the container and the machine for any damage. A damaged container  
could be an indication of damage to the unit. If there is damage to both the container and the unit, DO NOT throw away the  
container. The dishmachine has been inspected and packed at the factory with the expectation that it will arrive to you in new,  
undamaged condition. However, rough handling by carriers or others may damage the unit while in transit. If this situation does  
occur, do not return the unit to Ecolab; instead contact the carrier and ask them to inspect the damage to the unit and to com-  
plete an inspection report. You must contact the carrier within 48 hours of receiving the machine. Also, contact your Ecolab rep-  
resentative.  
UNPACKING THE DISHMACHINE: Remove the machine from the container and inspect for any missing parts. If an item  
appears to be missing, contact your Ecolab representative immediately to report it.  
LEVEL THE DISHMACHINE: The dishmachine(s) covered in this manual are designed to operate on  
a level surface. Ensure that the machine is level from side to side and from front to back; adjust the  
unit’s bullet feet as required. Failure to level the dishmachine may cause decreased washing perfor-  
mance.  
Lower  
Raise  
Frame with Adjustable Foot  
PLUMBING THE DISHMACHINE: All plumbing connections must comply with all applicable local, state and national plumbing  
codes. The plumber is responsible for flushing the incoming water line prior to connecting it to remove all foreign debris that  
may get trapped in the valves or cause an obstruction. Any valves that are fouled by matter left in the water line and the expens-  
es resulting are not the responsibility of the manufacturer.  
CONNECTING THE DRAIN LINE: The Omega 5 drain requires a minimum 2” NPT piping that is pitched  
at least 1/4” per foot. There must also be an air gap between the machine drain line and the floor sink  
or drain. If a grease trap is required by code, it should have a flow capacity of 5 gallons per minute.  
WATER SUPPLY CONNECTION: Install the water supply line (1/2” NPT minimum) to the dishmachine  
line y-strainer using copper pipe. It is recommended that a water shut-off valve be installed between the  
main supply and the machine to allow for service. The water supply line must be capable of 20 5 PSI  
Drain Connection  
“flow” pressure at the recommended temperature as indicated on the data plate.  
In areas where the water pressure fluctuates or is greater than the recommended pressure, it is sug-  
gested that a water pressure regulator be installed. The Omega 5 does not come with a water pressure  
regulator as standard equipment.  
It is also recommended that a shock absorber (not supplied with the Omega 5) be installed in the incom-  
ing water line. This prevents line hammer (hydraulic shock), induced by the solenoid valve, which can  
cause damage to the equipment.  
Y-Strainer  
PLUMBING CHECK: Slowly turn on the water supply to the machine after connecting the incoming fill line and drain line. Check  
for leaks and repair as required. Leaks must be repaired prior to placing the machine in operation.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS  
ELECTRICAL INSTALLATION INSTRUCTIONS  
ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with all applicable portions of the  
National Electric Code (ANSI/NFPA 70) and/or other electrical codes that may apply.  
Disconnect the electrical power supply and lockout the disconnect switch to indicate that you are working on the circuit.  
The dishmachine data plate is located on the left front corner of the machine. Refer to this data plate for information concern-  
ing the unit’s specific electrical requirements.  
To install the incoming power lines, open the connection box by removing the con-  
nection box lid. Install 1/2” conduit into the pre-punched holes in the back of the con-  
nection box. Route the power wires and connect to the power block and grounding  
lug. Install the service wires (L1 and N) to the appropriate terminals as they are  
marked on the terminal block. Install the grounding wire into the lug provided. Wires  
should be firmly secured in place.  
It is recommended that “De-Ox” or another similar anti-oxidation agent be used on  
all voltage connections.  
VOLTAGE CHECK: Ensure that the machine is off and apply power to the machine.  
Check the incoming power at the terminal block and ensure it corresponds to the  
voltage on the machine data plate. Do not run the dishmachine if the voltage is too  
high or too low. Shut off the service breaker and mark it as being for the dishma-  
Power Block  
chine. Advise all personnel of the location of the service breaker. Replace all covers  
and tighten the screws.  
Ground Lug  
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on  
this page is for reference only and may be subject to change without notice.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS  
OPERATION INSTRUCTIONS  
OPERATIONAL START-UP AND CHECK: Before proceeding with the start-up, verify the following:  
1. Open the door and verify that the sump strainer is correctly installed in the sump.  
2. Verify that the drain stopper is in position.  
3. Check that the plugs are securely screwed into the ends of the wash arm.  
4. Check that the wash arm is securely screwed into the stationary base and that it rotates freely.  
5. Check the levels in all chemical containers and replace if necessary.  
INSTALLATION/INITIAL START-UP PROCEDURE:  
1. Turn on dishmachine  
a) Turn on the incoming power to the machine at the circuit disconnect box.  
b) Turn on the dishmachine by pressing the ON/OFF button. The red light will come on.  
c) Check voltage at incoming terminals L1& L2. The voltage measured at these points should match data plate voltage.  
d) If voltages are in required range, close the control box cover.  
2. Fill Rinse Booster Heater with Water  
a) Before the heater element can be energized, the rinse booster heater must be initially filled with water. Damage to the heater  
element will occur if the element is not submerged in water. To initially fill the booster heater with water:  
i) Press and hold the FILL button to turn on the incoming water solenoid valve. Continue holding the button until you hear water  
entering the wash chamber through the airgap, then release the button. The rinse booster heater is now filled with water.  
ii) Turn off the unit by pressing the on/off switch.  
3. Enable Heater Element  
a) For the initial start-up only, the heater element must be enabled. The machine is shipped from the factory with the heater ele-  
ment disabled. This is done to ensure that the heater element is not damaged by energizing the element without the element being  
submerged in water. To enable the heater element:  
i) Remove the booster heater cover panel.  
ii) Connect the tagged white/blue wires.  
iii) Replace heater cover.  
iv) Press the on/off switch, heaters will energize to maintain booster heater temperature.  
Note: Water must be in the sump while the machine is running to avoid running the pump dry and causing damage to the pump  
seal.  
4. Adjust dishmachine fill level.  
If the water level is not between the linses on the drain standpipe, it will require adjustment. Check to ensure that the recommended  
water pressure is being supplied to the machine (20 ±5 PSI is required). If the water pressure is correct then the electronic timer will  
need adjustment. Use the following steps to adjust the fill time.  
A. Open control box cover.  
B. Adjust fill time as per instructions on [aseio of this section.  
C.Open and close the door to run a cycle, then check the water level. Adjust as necessary then close the control box cover.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS  
OPERATION INSTRUCTIONS (CONTINUED)  
NOTE: The machine must run a complete cycle to drain and fill. If the machine is not allowed to drain, the water will build up inside  
the tub. After the initial fill, the rinse water for the current cycle will become the wash water for the next cycle.  
The dishmachine is now ready to proceed with the washing of dishes.  
WARNING: Certain materials, including silver, silver plate, aluminum and pewter, are attacked by sodium hypochlorite sanitizers  
(bleach).  
PREPARING DISHES: Preparation of the ware will help ensure good results and less re-washes. If not done properly the dishes will  
not be clean and will reduce the efficiency of the dishmachine.  
The following steps should be followed to ensure good results:  
A. Remove all scraps and gross soil into a garbage can.  
B. Separate and pre-soak silverware.  
C. Separate and pre-soak the egg and casserole dishes.  
D. Scrape all ware with a brush or spatula.  
E. Flush cups, bowls and glasses with running water.  
F. Prewash dishware by soaking or spraying with a pre-rinse hose.  
G. Place dishes and cups in dish rack. Cups should be upside down (so they don’t hold water).  
H. Place glasses and flatware in their respective racks. Scatter flatware loosely in rack. Glasses should be placed upside down in a  
properly sized rack. For optimal results, flatware should be washed twice, the first being horizontal, the second in a special rack to  
hold flatware vertical.  
DAILY MACHINE PREPARATION: Before proceeding with start-up, verify the following:  
A. Open door and verify that the sump strainer is in place in the sump.  
B. Verify that the drain stopper is in position.  
C. Check that the plugs are securely screwed into the ends of all wash arms.  
D. Check that the wash arms are securely screwed into the stationary bases and rotate freely.  
E. Check levels in all chemical containers and replace if empty.  
F. For initial fill, close doors then depress the “FILL” switch to the “FILL” position.  
WASHING A RACK OF WARE:  
A. Open doors, place a full rack into the machine, and close doors. Push the start switch and hold until unit starts (about 2 seconds).  
B. After cycle is completed open doors and remove rack.  
C. Repeat steps A and B.  
SHUT DOWN AND CLEANING:  
A. At the end of mealtime, move the “ON/OFF” switch to the “OFF” position.  
B. Open doors and manually remove drain stopper to drain the unit.  
C. Remove and clean upper and lower wash arms.  
D. Remove and clean the sump strainer.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS  
CHEMICAL DISPENSING EQUIPMENT  
WARNING: CHLORINE-BASED SANITIZERS CAN BE DETRIMENTAL TO YOUR MACHINE IF THE CHEMICAL  
SOLUTION IS TOO STRONG. SEE YOUR CHEMICAL PROFESSIONAL TO ENSURE YOUR DISPENSER IS SET  
UP CORRECTLY.  
This equipment is not recommend for use with deionized water or other aggressive fluids. Use of deionized water or  
other aggressive fluids will result in corrosion and failure of materials and components. Use of deionized water or  
other aggressive fluids will void the manufacturer's warranty.  
TO PREPARE CHEMICAL FEEDER PUMPS FOR OPERATION  
The Delta 5 dismachines are supplied with detergent, rinse additive and sanitizer dispensing chemical feeder pumps. Locate  
the open ends of the chemical tubes with the tube stiffeners and place each one in the appropriate container.  
A. Red Tubing = Detergent  
B. Blue Tubing = Rinse Aid  
C. White Tubing = Sanitizer  
PRIMING CHEMICAL FEEDER PUMPS  
Chemical feeder pumps need priming when the machine is first installed or if for some reason the chemical lines have been  
removed and air is allowed to enter.  
CAUTION: Water must be in the sump and wash tank prior to the dispensing of chemicals. Sanitizer in con  
centration is caustic and may cause damage without dilution.  
1. Verify that the proper chemical tube stiffener inlet is in the proper container.  
2. Use the prime switches located on the control panel at the bottom of the unit to prime each pump. The switches are clear-  
ly marked as to what chemical feeder pump they are assigned to.  
3. To prime the pumps, hold the switch in the momentary position until chemical can be observed entering the sump.  
4. Detergent is dispensed as required during the wash cycle by the universal timer. The amount of detergent may need to be  
increased or decreased depending on water quality and type of detergent.  
5. Rinse additive is dispensed as required into the final rinse. The amount of rinse aid may need to be adjusted depending on  
water hardness and results.  
6. Sanitizer (either chlorine or iodine) is dispensed into the final rinse. The amount of sanitizer may need to be adjusted  
depending on the concentration and type of sanitizer used.  
7. Please refer to the next page for instruction on adjusting the chemical feeder pumps on the universal timer.  
WARNING: Some of the chemicals used in dishwashing may cause chemical burns if they come in contact  
with your skin. Wear protective gear when handling these chemicals. If you do come in contact with these  
chemicals, immediately flush the affected area with fresh water.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS  
PROGRAMMING INSTRUCTIONS FOR CHEMICAL FEEDER PUMPS (FOR INSTALLATION TECHNICIAN ONLY)  
To access the programming mode, the machine must be ON, and idle (between cycles).  
On the timer board, press and hold both the MOVE and ENTER buttons on the timer board simultaneously for two seconds.  
The PROGRAM light will illumniate.  
Once in the programming mode, the MOVE button is used to scroll between the programming categories and the ENTER but-  
ton is used to select the category.  
Press the MOVE button to move the blinking light between FILL, RINSE AID, DETERGENT or SANITIZER.  
Press the ENTER button for the chosen category.  
The PROGRAM light will illuminate.  
To change the value of a parameter, use the MOVE button to illuminate the light next to the time option (time is in seconds). In  
the time categories, each second in use will light up. To deselect the option, press ENTER and the light will go off, press ENTER  
again and it will illuminate. Once you have set your time category, press the MOVE button to the ACCEPT option and press  
ENTER. This will save the changed parameters.  
Once you press the ENTER button when the ACCEPT option is illuminated, you will exit the programming mode. To change  
any other values, you will have to return to the programming mode. To revert back to a previous setting, you must return to that  
option and change the parameter back to the previous setting.  
Once in the programming mode, if there have been no keypad inputs for approximately 2 minutes, the system will automati-  
cally exit out of the programming mode. Any changes to parameters will be saved when the programming mode is automati-  
cally exited.  
The wash and drain settings are not adjustable.  
All time adjustments are in seconds. Refer to the chart below for the adjustable outputs.  
Timer Programming Board  
Time in Seconds  
Rinse Aid  
Fill  
Sanitizer  
Detergent  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS  
DETERGENT CONTROL  
Detergent usage and water hardness are two factors that contribute greatly to how efficiently your dishmachine will operate. Using deter-  
gent in the proper amount can become, in time, a source of substantial savings. A qualified water treatment specialist can tell you what  
is needed for maximum efficiency from your detergent, but you should still know some basics so you’ll understand what they are talking  
about.  
First, you must understand that hard water greatly effects the performance of the dishmachine. Water hardness is the amount of dis-  
solved calcium and magnesium in the water supply. The more dissolved solids in the water, the greater the water hardness. Hard water  
works against detergent, thereby causing the amount of detergent required for washing to increase. As you use more detergent, your  
costs for operating the dishmachine will increase and the results will decrease. The solids in hard water also may build-up as a scale on  
wash and rinse heaters, decreasing their ability to heat water. Water temperature is important in removing soil and sanitizing dishes. If  
the water cannot get hot enough, your results may not be satisfactory. This is why Jackson recommends that if you have installed the  
machine in an area with hard water, that you also install some type of water treatment equipment to help remove the dissolved solids  
from the water before it gets to the dishmachine.  
Second, hard water may have you adding drying agents to your operating cycle to prevent spotting, when the real problem is deposit-  
ed solids on your ware. As the water evaporates off of the ware, the solids will be left behind to form the spotting and no amount of dry-  
ing agent will prevent this. Again, using treated water will undoubtedly reduce the occurrences of this problem.  
Third, treated water may not be suitable for use in other areas of your operation. For instance, coffee made with soft water may have  
an acid or bitter flavor. It may only be feasible to install a small treatment unit for the water going into the dishmachine itself. Discuss  
this option with your qualified water treatment specialist.  
Even after the water hardness problems have been solved, there still must be proper training of dishmachine operators in how much  
detergent is to be used per cycle. Talk with your water treatment specialist and detergent vendor and come up with a complete training  
program for operators. Using too much detergent has as detrimental effects as using too little. The proper amount of detergent must be  
used for job. It is important to remember that certain menu items may require extra detergent by their nature and personnel need to be  
made aware of this. Experience in using the dishmachine under a variety of conditions, along with good training in the operation of the  
machine, can go a long way in ensuring your dishmachine operates as efficiently as possible.  
Certain dishmachine models require that chemicals be provided for proper operation and sanitization. Some models even require the  
installation of third-party chemical feeders to introduce those chemicals to the machine. Jackson does not recommend or endorse any  
brand name of chemicals or chemical dispensing equipment. Contact your local chemical distributor for questions concerning these sub-  
jects.  
Some dishmachines come equipped with integral solid detergent dispensers. These dispensers are designed to accommodate deter-  
gents in a certain sized container. If you have such a unit, remember to explain this to your chemical distributor upon first contacting  
them.  
As explained before, water temperature is an important factor in ensuring that your dishmachine functions properly. The data plate locat-  
ed on each unit details what the minimum temperatures must be for either the incoming water supply, the wash tank and the rinse tank,  
depending on what model of dishmachine you have installed. These temperatures may also be followed by temperatures that Jackson  
recommends to ensure the highest performance from you dishmachine. However, if the minimum requirements are not met, the chances  
are your dishes will not be clean or sanitized. Remember, a dish can look clean, but it may not be sanitized. Instruct your dishmachine  
operators to observe the required temperatures and to report when they fall below the minimum allowed. A loss of temperature can indi-  
cate a much larger problem such as a failed heater or it could also indicate that the hot water heater for your operation is not up to capac-  
ity and a larger one may need to be installed.  
There are several factors to consider when installing your dishmachine to ensure that you get the best possible results from it and that  
it operates at peak efficiency for many years. Discuss your concerns with your local chemical distributor and water treatment specialist  
before there is a problem.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 3:  
PREVENTATIVE MAINTENANCE  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 3: PREVENTATIVE MAINTENANCE  
PREVENTATIVE MAINTENANCE  
The dishmachines covered in this manual are designed to operate with a minimum of interaction with the operator. However,  
this does not mean that some items will not wear out in time. Jackson highly recommends that any maintenance and repairs  
not specifically discussed in this manual should be performed by QUALIFIED SERVICE PERSONNEL ONLY. Performing main-  
tenance on your dishmachine may void your warranty if it is still in effect.  
There are many things that operators can do to prevent catastrophic damage to the dishmachine. One of the major causes of  
component failure has to do with prescrapping procedures. A dishmachine is not a garbage disposal; any large pieces of mate-  
rial that are put into the machine shall remain in the machine until they are either broken up (after spreading out on your ware!)  
or physically removed. Strainers are installed to help catch debris, but they do no good if they are clogged. Have operators reg-  
ularly inspect the pan strainers to ensure (1) that they are free of soil and debris and (2) they are laying flat in the tub.  
When cleaning out strainers, do NOT beat them on waste cans. The strainers are made of metal and can be forgiving; but once  
severe damage is done, it is next to impossible for the strainer to work in the way it was designed to. Wipe out strainers with  
a rag and rinse under a faucet if necessary. For stubborn debris, a toothpick should be able to dislodge any obstructions from  
the perforations. Always ensure that strainers are placed back in the machine before operation and that they lay flat in the tub.  
You may wish to also refer to the page entitled “Detergent Control” in order to learn more about how your water hardness will  
effect the performance of your machine. Hard water makes dishmachines work harder and decreases efficiency.  
Again, it is important to remind operators that trying to perform corrective maintenance on the dishmachine could lead to larg-  
er problems or even cause harm to the operator. If a problem is discovered; secure the dishmachine using proper shut down  
procedures as listed in this manual and contact a QUALIFIED SERVICE AGENCY.  
Some problems, however, may having nothing to do with the machine itself and no amount of preventative maintenence is  
going to help. A common problem has to do with temperatures being too low. Verify that the water temperatures coming to your  
dishmachine match the requirements listed on the machine data plate. There can be a variety of reasons why your water tem-  
perature could be too low and you should discuss it with a QUALIFIED SERVICE AGENCY to determine what can be done.  
By following the operating and cleaning instructions in this manual, you should get the most efficient results from your machine.  
As a reminder, here are some steps to take to ensure that you are using the dishmachine the way it was designed to work:  
1. Ensure that the water temperatures match those listed on the machine data plate.  
2. Ensure that all strainers are in place before operating the machine.  
3. Ensure that all wash and/or rinse arms are secure in the machine before operating.  
4. Ensure that drains are closed/sealed before operating.  
5. Remove as much soil from dishes by hand as possible before loading into racks.  
6. Do not overfill racks.  
7. Ensure that glasses are placed upside down in the rack.  
8. Ensure that all chemicals being injected to machine have been verified as being at the correct concentrations.  
9. Clean out the machine at the end of every workday as per the instructions in the manual.  
10. Always contact a QUALIFIED SERVICE AGENCY whenever a serious problem arises.  
11. Follow all safety procedures, whether listed in this manual or put forth by local, state or national codes/regulations.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 4:  
TROUBLESHOOTING  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 4: TROUBLESHOOTING SECTION  
COMMON PROBLEMS  
WARNING: Inspection, testing and repair of electrical equipment should be performed only by qualified service per  
sonnel. Certain procedures in this section require electrical tests or measurements while power is applied to the  
machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect power, attach test  
equipment and reapply power to test. When replacing electrical parts, disconnect power at source circuit breaker.  
Problem: Water overflow from bottom of door.  
1. Clogged drain. Remove obstruction.  
2. Machine not level. Level machine, or increase height to the front.  
3. Excessive inlet pressure. Install pressure reducing valve, or adjust if one is present. Ensure flow is 20 5 PSI.  
4. Detergent foaming. Reduce detergent quantity.  
5. Excessive fill time. Adjust timer fill time as per Section 2.  
Problem: Wash motor doesn’t operate on manual wash.  
1. Loose or broken wires. Reconnect or replace wires in motor.  
2. Defective manual wash switch. Replace.  
3. Defective motor starting relay. Replace.  
Problem: Motor operates on manual wash/delime but not on automatic.  
1. Defective circuit in manual wash switch. Replace switch.  
Problem: No water comes through the rinse arms when the “FILL” switch is depressed.  
1. Water not turned on. Turn water on.  
2. Defective solenoid valve. Replace solenoid valve.  
Problem: Little or no water coming through the rinse assemblies.  
1. Limed up rinse heads or piping. Delime rinse heads.  
2. Low water pressure. Increase pipe size to machine. Adjust pressure regulator.  
Problem: Rinse water runs continuously with breaker turned off.  
1. Defective plunger in solenoid valve. Replace.  
2. Defective diaphragm in solenoid valve. Replace diaphragm.  
Problem: Wash temperature not at required reading on thermometer.  
1. Check that white/blue wires are connected. See note on page 12.  
2. Defective thermometer. Replace.  
3. Defective thermostat. Adjust thermostat. Replace thermostat.  
4. Rinse heater defective. Replace heater element.  
5. Defective heater contactor R2. Replace.  
6. Incoming inlet water temperature below required minmum.  
7. Defective heater delay relay (R4). Replace  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTON 4: TROUBLESHOOTING SECTION  
COMMON PROBLEMS  
WARNING: Inspection, testing and repair of electrical equipment should be performed only by qualified service personnel.  
Certain procedures in this section require electrical tests or measurements while power is applied to the machine. Exercise  
extreme caution at all times. If test points are not easily accessible, disconnect power, attach test equipment and reapply  
power to test. When replacing electrical parts, disconnect power at source circuit breaker.  
Problem: Rinse water not at required temperature range.  
1. Check that white/blue wires are connected. See note in installation instructions.  
2. Thermometer is defective. Replace.  
3. Thermostat is defective. Adjust the thermostat. Replace if necessary.  
4. Incoming rinse water does not meet minimum criteria indicated on machine data plate. Adjust as required.  
Problem: No indication of pressure.  
1. Water turned off. Turn water on.  
2. Pressure gauge defective. Replace pressure gauge.  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5:  
PARTS SECTION  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
CHEMICAL FEEDER PUMP ASSEMBLY  
Squeeze Tube Lubricant  
Housing Kit (Red roller)  
Mfg. No.: 04320-121-37-10  
Motor, 36 RPM 115V  
Detergent/Sanitizer Feeder Pump  
Mfg. No.: 04320-111-35-14  
Motor, 14 RPM 115V  
Rinse Aid Feeder Pump  
Mfg. No.: 04320-111-35-13  
Motor, 36 RPM 240V  
Detergent/Sanitizer Feeder Pump  
Mfg. No.: 04320-111-47-47  
Squeeze Tube, Detergent/Sanitizer  
(Use with the red roller.)  
Roller, Red (Detergent/Sanitizer)  
Mfg. No.: 04320-111-36-70  
Motor, 14 RPM 240V  
Rinse Aid Feeder Pump  
Mfg. No.: 04320-111-47-46  
Mfg. No.: 05700-111-35-29  
Roller, White (Rinse Aid)  
Mfg. No.: 04320-002-82-28  
Clear Squeeze Tube, Rinse Aid  
(Use with the white roller.)  
Mfg. No.: 05700-011-76-41  
Motor, 14 RPM 24V  
Rinse Aid Feeder Pump  
Mfg. No.: 04320-011-63-33  
Roller, Black  
Mfg. No.: 04320-111-65-27  
Tube, Small 7/32”  
(Use with the black roller.)  
Mfg. No.: 05700-011-65-21  
1/4” Sight Tube  
3/8” Sight Tube  
Ecolab No.: 92001017  
Ecolab No.: 96569496  
Mfg. No.: N/A  
Mfg. No.: 05700-111-35-33  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
SOLENOID VALVE REPAIR PARTS KITS  
Screw  
Data Plate  
Cap Screw  
Coil and Housing  
Data Plate  
Valve Bonnet  
Cap  
Spring & Plunger Kit  
06401-003-07-40  
Spring position is moved  
for clarity. Goes below  
the plunger.  
Cap Retainer  
O-Ring & Diaphragm  
06401-003-07-41  
Diaphragm  
Retainer  
O-Ring  
Plunger  
Screen Retainer  
Valve Body  
Components of Repair  
Kit 06401-003-06-23  
Body  
Mesh Screen  
Complete Vacuum Breaker Assembly, 1/2” NPT  
04820-003-06-13  
Water Hammer Arrestor Assembly  
05700-002-64-67  
Complete 110 Volt Solenoid Valve Assembly, 1/2”  
04810-100-12-18  
Water Hammer  
Arrestor, 1/2" NPT  
06685-100-05-00  
Coil & Housing only, 1/2”  
06401-003-07-43  
Complete 220 Volt Solenoid Valve Assembly, 1/2”  
04810-100-09-18  
Coil & Housing only, 1/2”  
06401-003-07-44  
Close Nipple, 1/2”  
04730-207-15-00  
Tee, 1/2” x 1/2” x 1/2”  
04730-211-27-00  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
CONTROL BOX ASSEMBLY  
1
9, 10  
5
2
3
6
Normal/Delime  
7
Rinse Aid/Detergent  
8
4
Sanitizer  
11, 27  
11, 27  
14  
15  
12, 13, 28  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
CONTROL BOX ASSEMBLY  
16, 27  
32  
29  
19  
17, 28  
18, 27  
30  
31  
17, 28  
20  
21  
24, 27  
25, 26, 27  
27  
22, 23  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
CONTROL BOX ASSEMBLY (CONTINUED)  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
1
2
3
4
5
6
7
8
1
1
1
4
1
1
1
1
1
1
2
1
1
4
1
5
2
1
1
1
1
1
2
1
1
1
18  
4
1
1
1
1
Control Box Weldment  
Control Box Cover  
05700-003-38-84  
05700-003-30-54  
09905-100-75-93  
05305-011-39-36  
09905-003-32-56  
05930-301-21-18  
05930-011-35-27  
05930-111-38-21  
05310-374-01-00  
05311-174-01-00  
05945-109-05-69  
05945-003-33-09  
05700- 003-02-08  
05975-011-49-03  
05975-011-65-51  
04730-011-39-01  
05945-111-35-19  
05940-021-94-85  
05700-003-35-37  
05975-003-33-28  
05700-003-35-48  
05990-111-35-38  
05305-002-32-38  
05940-002-78-97  
05940-001-97-91  
09905-003-09-30  
05310-373-01-00  
05310-373-03-00  
05700-003-35-34  
05700-003-35-36  
05700-003-35-35  
05700-003-35-49  
Decal, Warning - Disconnect Power  
Screw, 10-32 x 1/2’’ Long, Phillips Tusshead  
Decal, Peri-pump Prime  
Switch, Delime/Normal  
Detergent/Rinse Aid Pump Prime Switch  
Sanitizer Pump Prime Switch  
Locknut, 1/4”-20 S/S Hex with Nylon Insert  
Washer, 1/4”-20 S/S  
Contactor  
Timer, Universal  
Bracket, Timer  
Fitting, Conduit, Heyco 1/2’’  
Fitting, 1/2’’ Straight Snap In  
Clamp, 5/8” Nylon  
Relay, 2 Pole  
Terminal Board  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
Harness, Switch Panel  
Fitting, 1/2’’ 90 Deg. Snap In  
Conduit, 1/2” x 40”  
Cycle Counter, 115V  
Screw, 4-40 x 1/4” Phillips Pan Head  
Terminal Board  
Terminal Board  
Decal, Terminal Board 8 Position  
Locknut, 10-24 S/S Hex with Nylon Insert  
Locknut, 6-32 S/S Hex with Nylon Insert  
Harness, Wash Pump  
Harness, Drain Solenoid  
Harness, Peri-pump  
Conduit, 1/2” x 14”  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
PERI-PUMP BOX ASSEMBLY  
7
6
9
1  
15  
5
4
1
8
2
10  
3
16  
12  
18  
14  
17  
13  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
1
2
3
4
5
6
7
8
2
1
1
1
1
1
1
1
5
3
3
1
1
1
1
1
1
1
Peri-pump Assembly, 36 RPM  
Peri-pump Assembly, 14 RPM  
Drip Channel  
Weldment, Peri-pump Box  
Weldment, Peri-pump Box Cover  
Fitting, Conduit, Heyco 1/2’’  
Clamp, 5/8” Nylon (Located inside of box)  
Clamp, 1” Nylon  
Screw, 10-32 x 1/2’’ Long, Phillips Tusshead  
Locknut, 10-24 S/S Hex with Nylon Insert  
Tube Stiffener (Not Shown)  
Tubing, 1/4’’ OD x 60” Long, Blue  
Tubing, 1/4’’ OD x 60” Long, White  
Tubing, 1/4’’ OD x 60” Long, Red  
Terminal Board (Not Shown)  
Tubing,1/4 OD x 120 Long Blue  
Tubing,1/4 OD x 120 Long Write  
Tubing,1/4 OD x 120 Long Red  
05700-002-96-08  
05700-002-96-09  
05700-003-32-89  
05700-003-32-00  
05700-003-33-80  
05975-011-65-51  
04730-011-39-01  
04730-002-41-88  
05305-011-39-36  
05310-373-01-00  
05700-002-66-49  
05700-002-52-34  
05700-002-52-33  
05700-011-63-18  
05940-001-97-91  
05700-011-37-17  
05700-011-37-13  
05700-011-37-15  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
ELECTRICAL CONNECTION BOX ASSEMBLY  
1
5
2
3
7
10  
A
A
6
5
4
8
11  
A
9
ITEM QTY  
DESCRIPTION  
Box, Power Junction Weldment  
Terminal Block Spacer  
Terminal Block  
Locknut, 6-32 with Nylon Insert  
Locknut, 10-24 with Nylon Insert  
Lug, Ground  
Decal, Power Connection  
Decal, Warning to Disconnect Power  
Screw, 10-32 x 1/2’’ Long, Phillips Trusshead  
Decal, Copper Conductors Only  
Cover, Solenoid Box  
ECOLAB No.  
96633058  
96025127  
96025119  
88460050  
88429063  
83118000  
96028402  
96039821  
N/A  
Mfg. No.  
1
1
1
1
1
5
1
1
1
1
2
1
05700-003-30-58  
05700-011-40-05  
05940-500-09-61  
05310-373-03-00  
05310-373-01-00  
05940-200-76-00  
09905-011-47-64  
09905-100-75-93  
05305-011-39-36  
09905-011-47-35  
05700-003-46-72  
2
3
4
5
6
7
8
9
10  
11  
96021365  
96634672  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
FRAME ASSEMBLY  
5
ITEM QTY  
DESCRIPTION  
Mfg. No.  
1
2
3
4
5
6
7
8
1
1
4
1
1
1
1
8
1
4
5
1
1
1
Frame Weldment  
Frame Weldment Double Door  
Foot, 3” Adjustable  
Plate, Hinge Weldment  
Washer, Hinge Weldment  
Spacer, PB Bolt  
05700-003-09-40  
05700-003-28-12  
05340-002-14-55  
05700-003-10-11  
05700-002-54-62  
05700-000-29-40  
05700-000-35-05  
05311-174-01-00  
05700-003-09-31  
05310-374-01-00  
05310-274-01-00  
05700-002-51-93  
05700-003-14-53  
05305-274-02-00  
Clamp, Pipe  
Washer, 1/4”-20 S/S  
9
Keeper, Door Panel Latch  
Locknut, 1/4”-20 S/S Hex with Nylon Insert  
Nut, Hex 1/4”-20  
Booster Mounting Plate Weldment  
Bracket, Temperature Gauge  
Bolt, 1/4”-20 x 1/2” Long  
10  
11  
12  
13  
14  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
HOOD ASSEMBLY  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
1
1a  
2
3
4
5
6
7
8
1
1
Hood Weldment  
Hood Weldment Double Door  
Switch, 115V Reed  
Bracket, Limit Switch  
Locknut, 10-24 with Nylon Insert  
Clamp, Pipe 5/8”  
Rack Rail Weldment  
Washer, 1/4”-20 I.D.  
Gasket, Side Panel (5.3 Feet)  
05700-003-09-56  
05700-003-28-17  
05930-002-36-80  
05700-021-71-18  
05310-373-01-00  
05700-000-35-06  
05700-002-45-67  
05311-174-01-00  
05700-003-35-51  
1
1
4
2
2
2
1
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
SWITCH PANEL ASSEMBLY  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
Complete Side Panel Assembly  
Complete Side Fanel Assembly (Double Door)  
Side Panel Weldment  
05700-003-24-38  
05700-003-24-40  
05700-003-24-36  
05700-003-24-37  
05700-003-14-91  
05700-003-14-92  
05945-504-06-18  
05945-504-07-18  
09905-003-08-63  
05975-011-65-51  
04730-011-60-21  
05310-373-01-00  
05311-173-02-00  
09905-003-38-95  
05975-011-49-03  
05930-002-36-80  
05700-021-71-18  
05940-001-97-91  
1
1a  
2
3
4
5
6
7
8
1
1
2
1
1
1
1
1
3
6
6
Side Panel Weldment (Double Door)  
(3) Switch, Prime Assembly  
Switch, On/Off Assembly  
(2) Light, Amber  
(2) Light, Red  
Decal, Switch Panel  
Fitting, .25-.546  
(2) Plug, 3/4” hole  
9
Locknut, 10-24 with Nylon Insert  
Washer, #10  
10  
11  
12  
13  
14  
15  
1
Decal Switch Panel (Double Door Only)  
Fitting (Double Door Only)  
switch (Double Door Only)  
bracket (Double Door Only)  
Terminal Board  
1
1
1
1
ALL NUMBERS THAT ARE IN PARENTHISES ARE FOR THE DOUBLE DOOR  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
TUB ASSEMBLY  
14b  
14c  
14a  
27b  
27a  
16a  
16b  
30e  
30d  
30c  
30b  
30a  
17c  
17b  
17a  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
TUB ASSEMBLY CONTINUED  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
1
1a  
2
3
4
5
6
7
8
1
1
1
2
1
1
1
23  
1
1
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
18  
3
1
1
1
1
1
1
3
6
1
1
1
4
1
2
1
1
1
4
1
1
Tub Weldment  
05700-003-09-51  
05700-003-28-15  
05700-002-45-51  
05700-111-35-03  
05700-021-34-38  
05700-111-34-52  
05700-031-37-86  
05310-374-01-00  
05330-111-35-15  
09515-011-46-61  
05305-276-10-00  
05311-011-35-36  
05311-276-01-00  
05310-276-01-00  
05700-003-31-60  
05700-003-31-61  
05700-003-31-59  
05330-002-60-69  
05700-021-35-97  
05700-002-60-50  
05700-021-33-29  
05700-121-35-54  
05700-002-45-52  
05700-002-40-83  
05310-275-01-00  
05700-002-38-10  
05315-011-60-09  
05700-002-45-61  
05311-174-01-00  
05325-002-42-65  
05700-002-45-62  
05700-002-45-63  
03110-002-45-09  
05700-002-52-95  
05700-002-52-94  
03110-002-45-09  
05305-274-02-00  
05305-274-24-00  
05700-003-23-48  
05700-003-23-49  
05700-003-16-65  
04730-002-55-61  
05330-003-24-17  
04730-002-41-88  
05700-003-09-61  
05700-003-35-88  
04810-200-11-00  
05310-373-01-00  
09905-100-75-93  
05700-003-30-25  
Tub Weldment (Double Door)  
Lower Manifold Weldment  
Manifold Gasket  
Drain Seat Insert  
Spillway Gasket  
Spillway Weldment  
Locknut, 1/4”-20 S/S Hex with Nylon Insert  
Manifold O-Ring  
Modified Casting Wedge  
Bolt, 3/8”-16 x 1 1/4” S/S  
Washer, 3/8” Bevel-Square Iron  
Lockwasher, 3/8”  
9
10  
11  
12  
13  
14  
14a  
Nut, 3/8”-16 S/S Hex  
Complete Wash Arm Assembly  
Wash Arm Weldment w/ End Plugs  
Wash Arm End Plugs  
Wash Arm O-ring  
Wash Arm Bearing Assembly  
Sump Strainer  
Stand Pipe Weldment  
Stopper, Stand Pipe  
Drain Link Assembly  
Drain Link  
14b  
14c  
15  
16a  
16b  
17  
17a  
17b  
17c  
18  
19  
20  
21  
22  
22a  
22b  
23  
23a  
23b  
24  
25  
26  
27  
27a  
27b  
28  
29  
30  
30a  
30b  
30c  
30d  
30e  
Nut, Hex, 5/16”-18  
Drain Link Connector  
Hair Pin, 1/8” to 1”  
Fill Tube Weldment  
Washer, 1/4”-20 I.D.  
Chemical Tube Grommet  
(2) Pivot Plate, Left Door Complete Assembly  
Door Pivot Plate Left Weldment  
Door Pivot Plate Bearing  
(2) Pivot Plate, Right Door Complete Assembly  
Door Pivot Plate Right Weldment  
Door Pivot Plate Bearing  
Bolt, 1/4”-20 x 1/2” Long  
Screw, 1/4”-20 x 5/8” Long  
Air Gap Weldment  
Halo Assembly  
Halo Weldment  
Spray Nozzle and Receptacle  
Gasket, Air Gap  
Clamp, 1” Nylon (Not Shown, located on bottom of tub.)  
Drain Solenoid Box Assembly  
Solenoid Box Weldment  
Drain Solenoid, 115V  
Locknut, 10-24 with Nylon Insert  
Decal, Warning  
Solenoid Box Cover  
ALL NUMBERS THAT ARE IN PARENTHISES ARE FOR THE DOUBLE DOOR  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
FRAME AND MOTOR ASSEMBLY  
10  
1
11  
See Motor  
Assembly  
Page  
4
2
11  
11  
3a  
3b  
See Plumbing  
Assembly  
Page  
6
See Booster  
Assembly  
Page  
12  
5
8
9
7
See Frame  
Assembly  
13  
Page  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
FRAME AND MOTOR ASSEMBLY (CONTINUED)  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
1
2
3
3a  
3b  
4
5
6
7
8
9
10  
11  
12  
13  
1
1
1
2
1
1
1
1
Discharge Tube Connector  
Pump Suction Hose  
05700-011-70-34  
05700-002-40-82  
05700-002-45-58  
04730-011-93-99  
05700-002-45-59  
05700-002-84-69  
05700-003-33-25  
05700-002-51-95  
05305-274-02-00  
05310-374-01-00  
05311-174-01-00  
04730-719-06-09  
04730-719-18-00  
04730-207-15-00  
06685-111-68-48  
Discharge Hose Assembly  
Fitting, 1/2” Pushlock, Female, Brass  
Hose, 1/2” x 22 1/2” Long  
Wash Restrictor  
Accumulator Strainer Weldment  
Accumulator Weldment  
Bolt, 1/4”-20 x 1/2” Long  
Locknut, 1/4”-20 S/S Hex with Nylon Insert  
Washer, 1/4”-20 S/S  
Hose Clamp, 13/16 TO 1 1/2”  
Hose Clamp, 1 1/16” to 2 1/4”  
Close Nipple, 1/2” Brass  
Gauge, Thermometer  
8
18  
18  
1
3
1
1
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
MOTOR & PUMP ASSEMBLY  
Complete Pump & Motor Assembly  
Mfg. No.: 06105-002-16-29  
Pump Only Assembly  
Mfg. No.: 05700-002-79-49  
Motor Only  
Mfg. No.: 06105-002-79-61  
Impeller Assembly  
Mfg. No.: 05700-002-81-86  
Shim Kit  
Mfg. No.: 05700-002-82-58  
Pump Casing  
Mfg. No.: 05700-002-84-99  
Case O-Ring  
Mfg. No.: 05330-002-81-83  
Seal Plate  
Mfg. No.: 05700-002-81-87  
Mechanical Seal  
Mfg. No.: 05330-002-34-22  
Other parts not shown.  
Drain Plug  
Mfg. No.: 04730-002-81-89  
Case Capscrew  
Mfg. No.: 05305-002-81-88  
Motor Mounting Bracket  
Mfg. No.: 05700-002-55-52  
Lockwasher, 3/8”  
Mfg. No.: 05311-276-01-00  
Nut, Hex 3/8”-16 S/S  
Mfg. No.: 05310-276-01-00  
Bolt, 3/8” x 3/4” Long Hex Head  
Mfg. No.: 05306-011-71-60  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
BOOSTER TANK ASSEMBLY  
13  
3
12  
10  
11  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
1
2
3
4
5
6
7
8
1
1
1
1
1
1
4
4
2
1
1
1
1
1
Booster Tank Weldment  
Heater, 120V, 2000 Watts  
Heater Gasket  
Thermostat  
Fitting, Imperial Brass  
Plug, 1/4” Brass  
05700-002-45-56  
04540-002-45-13  
05330-100-01-10  
05930-003-13-65  
05310-924-02-05  
04730-209-01-00  
05311-275-01-00  
05310-275-01-00  
05310-373-03-00  
05700-002-39-07  
09905-100-75-93  
05305-173-12-00  
05975-003-35-32  
05975-003-35-33  
Lockwasher, 5/16”  
Nut, 5/16”-18 S/S Hex  
Locknut, 6-32 S/S Hex w/ Nylon Insert  
Booster Tank Cover  
Decal, Warning, Disconnect Power  
Screw, 10-32 x 3/8”  
9
10  
11  
12  
13  
13a  
Fitting, 1/2” NPT x 90 Deg. Elbow  
Nut, 1/2” NPT Nylon  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
INCOMING PLUMBING ASSEMBLY  
5
4
3
2
6
ITEM QTY  
DESCRIPTION  
Mfg. No.  
1
2
3
4
5
6
1
1
1
1
1
1
Incoming Plumbing Assy.  
Y-Strainer  
Nipple, Close, 1/2’’ NPT, Brass  
Valve, Solenoid, 1/2’’ NPT, 115V  
Plumbing, incoming Union  
Fitting, Liquidtiht  
05700-003-38-08  
04730-217-01-10  
04730-207-15-00  
04810-100-12-18  
05700-003-39-37  
05975-011-49-03  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
DOOR ASSEMBLY  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
Complete Door Assembly  
(2) Door Weldment  
(2) Magnet, Reed Switch  
(2) Locknut, 6-32 S/S Hex with Nylon Insert  
(4) Locknut, 1/4”-20 S/S Hex with Nylon Insert  
(2) Nut, Hex 1/4”-20 S/S  
(2) Bolt, 1/4”-20 Eye, S/S  
(2) Spring, Door  
05700-003-35-30  
05700-003-35-29  
05930-002-68-53  
05310-373-03-00  
05310-374-01-00  
05310-274-01-00  
05306-002-55-59  
05340-011-44-58  
1
2
3
4
5
6
7
2
2
4
2
2
2
2
ALL NUMBERS THAT ARE IN PARENTHISES ARE FOR THE DOUBLE DOOR  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5: PARTS SECTION  
FRONT PANEL ASSEMBLY  
Double Door Only  
Panel Clips  
2 per machine  
05340-003-22-95  
(Double Door Only)  
Back Panel Weldment  
1 per machine  
05700-003-24-42  
ITEM QTY  
DESCRIPTION  
Mfg. No.  
Complete Panel Assembly  
Panel Weldment  
Handle  
Back panel weldment  
Panel clips  
05700-003-09-53  
05700-003-09-54  
05340-001-96-30  
05700-002-24-42  
05700-033-22-95  
1
2
3
4
1
1
1
2
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6:  
ELECTRICAL SCHEMATICS  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6: ELECTRICAL SCHEMATICS  
DELTA 5 115V, 50/60 HERTZ, SINGLE PHASE  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7:  
JACKSON MAINTENANCE &  
REPAIR CENTERS  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS  
ALABAMA TO FLORIDA  
ALABAMA  
CALIFORNIA  
P & D APPLIANCE  
GCS SERVICE INC.  
PHILADELPHIA, PA  
(215)925-6217  
800-441-9115  
FAX: (215) 925-6208  
4220-C ROSEVILLE ROAD  
NORTH HIGHLANDS, CA 95660  
(916) 974-2772  
800-824-7219  
FAX:(916) 974-2774  
JONES-McLEOD APPLIANCE SVC BARKERS FOOD MACHINERY  
1616 7TH AVE. NORTH  
BIRMINGHAM, AL 35203  
(205) 251-0159  
SERVICES  
5367 SECOND STREET  
IRWINDALE, CA 91706  
(626) 960-9390  
800-821-1150  
ELMER SCHULTZ SERVICE  
FAX: (205) 322-1440  
800-258-6999  
FAX: (626) 337-4541  
COMMERCIAL APPLIANCE SER- 36 BELMONT AVE.  
VICE, INC.  
WILLMINGTON, DE 19804  
281 LATHROP WAY, #100  
SACRAMENTO, CA 95815  
(916) 567-0203  
(302) 655-8900  
800-225-0599  
FAX: (302) 656-3673  
JONES-McLEOD APPLIANCE SVC  
854 LAKESIDE DRIVE  
MOBILE, AL 36693  
GCS SERVICE INC.  
LOS ANGELES, CA  
(213) 683-2090  
(800) 464-2222  
(251) 666-7278  
(916) 567-0324 FAX  
800-237-9859  
FAX: (251) 661-0223  
800-327-1433  
FAX: (213) 683-2099  
EMR SERVICE DIVISION  
106 WILLIAMSPORT CIRCLE  
SALISBURY, MD 21804  
(410) 543-8197  
COLORADO  
ALASKA  
GCS SERVICE INC.  
SANTA ANA, CA  
GCS SERVICE INC.  
SHERIDAN, CO  
(303) 371-9054  
FAX: (410) 548-4038  
RESTAURANT APPLIANCE SER- (714) 542-1798  
VICE  
800-540-0719  
800-972-5314  
FLORIDA  
7219 ROOSEVELT WAY NE  
SEATTLE, WA 98115  
(206) 524-8200  
800-433-9390  
FAX: (206) 525-2890  
FAX: (714) 542-4787  
FAX: (303) 371-4754  
COMMERCIAL APPLIANCE SER-  
GCS SERVICE INC.  
S. SAN FRANCISCO, CA  
(650) 635-0720  
800-969-4427  
FAX: (650) 871-4019  
HAWKINS COMMERCIAL APPLI- VICE  
ANCE SERVICE  
3000 S. WYANDOT ST.  
ENGLEWOOD, CO 80110  
(303) 781-5548  
8416 LAUREL FAIR CIRCLE  
BLDG 6, SUITE 114  
TAMPA, FL 33610  
(813) 663-0313  
ARIZONA  
(800) 624-2117  
800-282-4718  
COMMERCIAL APPLIANCE SER- FAX: (303) 761-5561  
FAX: (813) 663-0212  
net  
AUTHORIZED COMMERCIAL  
FOOD EQMT. SVC  
4832 SOUTH 35TH STREET  
PHOENIX, AZ 85040  
(602) 234-2443  
VICE, INC.  
6507 PACIFIC AVENUE, SUITE  
102  
STOCKTON, CA 95207  
(916) 567-0203  
METRO APPLIANCE SERVICE  
1640 S BROADWAY  
DENVER, CO 80210  
(303) 778-1126  
GCS SERVICE INC  
MIAMI, FL  
(305) 621-6666  
800-766-8966  
800-824-8875  
(800) 464-2222  
FAX: (602) 232-5862  
(916) 567-0266 FAX  
800-525-3532  
FAX: (303) 778-0268  
FAX: (305) 621-6656  
GCS SERVICE INC.  
SAN DIEGO, CA  
(858) 549-8411  
GCS SERVICE INC.  
PHOENIX, AZ  
GCS SERVICE INC  
ORLANDO, FL  
CONNECTICUT  
(602) 474-4510  
800-422-7278  
(407) 841-2551  
800-510-3497  
FAX: (602) 470-4511  
FAX: (858) 549-2323  
GCS SERVICE INC.  
HARTFORD, CT  
(860) 549-5575  
800-423-1562  
800-338-7322  
FAX: (407) 423-8425  
INDUSTRIAL ELECTRIC SVC.  
5662 ENGINEER DRIVE  
HUNTINGTON BEACH, CA 92649 FAX: (860) 527-6355  
(714) 379-7100  
(800-457-3783  
ARKANSAS  
NASS PARTS AND SERVICE, INC.  
1144 BELVILLE ROAD, UNIT 359  
DAYTONA BEACH, FL 32114  
(386) 226-2642  
BROMLEY PARTS & SVC  
10TH AND RINGO  
SUPERIOR KITCHEN SERVICE  
P.O. BOX 1688  
FAX: (714) 379-7109  
INC.  
(800) 432-2795  
LITTLE ROCK, AR 72202  
(501) 374-0281  
800-482-9269  
FAX: (501) 374-8352  
22 THOMPSON ROAD  
WINDSOR, CT 06088  
(888) 590-1899  
(386) 736-7695 FAX  
P & D APPLIANCE SVC  
100 SOUTH LINDEN AVE.  
S. SAN FRANCISCO, CA 94080  
(650) 635-1900  
GCS SERVICE INC  
TAMPA, FL  
(813) 626-6044  
800-282-3008  
(888) 590-1996 FAX  
800-424-1414  
DELAWARE  
FAX: (650) 635-1919  
FAX: (813) 621-1174  
GCS SERVICE,INC.  
3717 CHERRY ROAD  
MEMPHIS, TN 38118  
(901) 366-4587  
FOOD SERVICE EQMT.  
2101 PARKWAY SOUTH  
BROOMALL, PA 19008  
(610) 356-6900  
800-262-9155  
FAX: (901) 366-4588  
FAX: (610) 356-2038  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS  
FLORIDA TO MARYLAND  
JONES-McLEOD APPLIANCE  
SVC  
854 LAKESIDE DRIVE  
MOBILE, AL 36693  
(251) 666-7278  
800-237-9859  
FAX: (251) 661-0223  
HAWAII  
INDIANA  
CERTIFIED SERVICE CENTER  
1051 GOODWIN DRIVE  
LEXINGTON, KY 40505  
(606) 254-8854  
800-432-9269  
FAX: (606) 231-7781  
FOOD EQMT. PARTS &  
SERVICE CO.  
300 PUUHALE RD.  
HONOLULU, HI 96819  
(808) 847-4871  
GCS SERVICE INC.  
INDIANAPOLIS, IN  
(317) 545-9655  
800-727-8710  
FAX: (317) 549-6286  
FAX: (808) 842-1560  
B622 LA PAS TRAIL  
INDIANAPOLIS, IN 46268  
(317) 290-8060  
GCS SERVICE INC.  
LOUISVILLE, KY  
(502) 367-1788  
800-752-6160  
FAX: (502) 367-0400  
NASS PARTS AND SERVICE, INC.  
1108 SOUTH WOODS AVENUE  
ORLANDO, FL 32805  
(407) 425-2681  
IDAHO  
(800) 410-9794  
RESTAURANT APPLIANCE SVC. (317) 290-8085 FAX  
(800) 432-2795  
7219 ROOSEVELT WAY NE  
(407) 425-3463 FAX  
SEATTLE, WA 98115  
(206) 524-8200  
IOWA  
GCS SERVICE INC.  
LEXINGTON, KY  
(606) 255-0746  
GOODWIN TUCKER GROUP  
NASS PARTS AND SERVICE, INC. 800-433-9390  
1376 HEIDE AVENUE  
PALM BAY, FL 32907  
(321) 952-2012  
FAX: (206) 525-2890  
2900 DELAWARE AVENUE  
DES MOINES, IA 50317  
(515) 262-9308  
800-432-9260  
FAX: (606) 255-0748  
(800) 432-2795  
RON'S SERVICE  
800-372-6066  
LOUISIANA  
(321) 953-0266 FAX  
703 E 44TH STREET STE 10  
GARDEN CITY, ID 83714  
(208) 375-4073  
FAX: (515) 262-2936  
HERITAGE SERVICE GROUP  
1532 RIVER OAKS WEST  
NEW ORLEANS, LA 70123  
(504) 734-8864  
(800) 499-2351  
(504) 733-2559 FAX  
GEORGIA  
FAX: (208) 375-4402  
CONES REPAIR SVC.  
1056 27TH AVENUE SW  
CEDAR RAPIDS, IA 52404  
(319) 365-3325  
800-747-3326  
FAX: (319) 365-0885  
GCS SERVICE INC  
ATLANTA, GA  
(770) 452-7322  
800-334-3599  
ILLINOIS  
CONES REPAIR SVC.  
2408 40TH AVE.  
MOLINE, IL 61265  
(309) 797-5323  
800-716-7070  
FAX: (309)797-3631  
FAX: (770) 452-7473  
MAINE  
HERITAGE FOODSERVICE  
GROUP OF ATLANTA  
2100 NORCROSS PKWY. SUITE  
130  
NORCROSS, GA 30071  
(770) 368-1465  
KANSAS  
GCS SERVICE INC.  
CHELSEA, MA  
(617) 889-9393  
800-225-1155  
FAX: (617) 889-1222  
GCS SERVICE INC.  
KANSAS CITY, MO  
(816) 920-5999  
800-229-6477  
FAX: (816) 920-7387  
EICHENAUER SERVICES INC.  
130 S OAKLAND ST.  
DECATUR, IL 62522  
(217) 429-4229  
800-252-5892  
FAX: (217) 429-0226  
866-388-9837  
FAX: (866) 388-9838  
MASSACHUSETTS RESTAU-  
RANT SUPPLY  
34 SOUTH STREET  
SOMERVILLE, MA 02143  
(617) 868-1930  
GENERAL PARTS, INC.  
1101 E. 13TH STREET  
KANSAS CITY, MO 64106  
(816) 421-5400  
WHALEY FOODSERVICE  
REPAIRS  
109-A OWENS INDUSTRIAL  
DRIVE  
800-338-6737  
FAX: (617) 686-5331  
(800) 279-9967  
SAVANNAH, GA 31405  
(912) 447-0827  
888-765-0036  
GCS SERVICE INC.  
ELMHURST, IL  
(630) 941-7800  
(816) 421-1270 FAX  
PINE TREE FOOD EQUIPMENT  
175 LEWISTON ROAD  
GRAY, ME 04039  
KENTUCKY  
FAX: (912) 447-0826  
800-942-9689  
FAX: (630) 941-6048  
CERTIFIED SERVICE CENTER  
127 DISHMAN LANE  
BOWLING GREEN, KY 42101  
(270) 783-0012  
(207) 657-6400  
(800) 540-5427  
(207) 657-5464 FAX  
PIERCE PARTS & SERVICE  
2422 ALLEN ROAD  
MACON, GA 31216  
(478) 781-6003  
GCS SERVICE INC.  
ST. LOUIS, MO  
(314) 683-7444  
(877) 907-0012  
MARYLAND  
800-368-2512  
800-284-4427  
FAX: (270) 783-0058  
FAX: (478) 781-7186  
FAX: (314) 638-0135  
EMR SERVICE DIVISION  
700 EAST 25TH STREET  
BALTIMORE, MD 21218  
(410) 467-8080  
800-879-4994  
FAX: (410) 467-4191  
CERTIFIED SERVICE CENTER  
RAMCO BUSINESS PARK  
4283 PRODUCE ROAD  
LOUISVILLE, KY 40218  
(502) 964-7007  
GENERAL PARTS, INC.  
248 JAMES STREET  
BENSONVILLE, IL 60106  
(630) 595-3300  
(800) 880-3604  
800-637-6350  
FAX: (630)595-0006  
FAX: (502) 964-7202  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS  
MARYLAND TO NEW YORK  
EMR SERVICE DIVISION  
106 WILLIAMSPORT CIRCLE  
SALISBURY, MD 21804  
(410) 543-8197  
MICHIGAN  
GCS SERVICE INC.  
ST. LOUIS, MO  
(314) 638-7444  
NEW HAMPSHIRE  
GCS SERVICE INC.  
LIVONIA, MI  
GCS SERVICE INC.  
CHELSEA, MA  
800-284-4427  
888-687-8080  
FAX: (410) 548-4038  
(248) 426-9500  
800-772-2936  
FAX: (248) 426-7555  
FAX: (314) 638-0135  
(617)889-9393  
800-225-1155  
FAX: (617) 889-1222  
KAEMMERLIN PARTS & SVC.  
2728 LOCUST STREET  
ST. LOUIS, MO 63103  
(314) 535-2222  
FAX: (314) 535-6205  
EMR SERVICE DIVISION  
5316 Sunnyside Ave.  
Beltsville, MD 20715  
(301) 931-7000  
ACE SERVICE CO.  
95 HAMPTON AVE.  
NEEDHAM, MA 02494  
(781) 449-4220  
800-225-4510 MA & NH  
FAX: (781) 444-4789  
JACKSON SERVICE COMPANY  
3980 BENSTEIN RD.  
COMMERCE TWSHP, MI 48382  
(248) 363-4159  
800-332-4053  
FAX: (248) 363-5448  
800-348-2365  
FAX: (301) 931-3060  
GCS SERVICE INC.  
SILVER SPRING, MD  
(301) 585-7550 (DC)  
(410) 792-0338 (BALT)  
(800) 638-7278  
GENERAL PARTS, INC.  
1101 EAST 13TH STREET  
KANSAS CITY, MO 64106  
(816) 421-5400  
(800) 279-9967  
(816) 421-1270 FAX  
GCS SERVICE INC.  
GRAND RAPIDS, MI  
(616) 241-0200  
800-823-4866  
FAX: (616) 241-0541  
MASSACHUSETTS RESTAURANT  
SUPPLY  
34 SOUTH STREET  
SOMERVILLE, MA 02143  
(617) 868-1930  
FAX: (301) 495-4410  
MONTANA  
800-338-6737  
MASSACHUSETTS  
MINNESOTA  
FAX: (617) 868-5331  
RESTAURANT APPLIANCE SVC.  
7219 ROOSEVELT WAY NE  
SEATTLE, WA 98115  
(206) 524-8200  
800-433-9390  
FAX: (206) 525-2890  
ACE SERVICE CO.  
95 HAMPTON AVE.  
NEEDHAM, MA 02494  
(781) 449-4220  
800-225-4510 MA & NH  
FAX: (781) 444-4789  
GCS SERVICE INC.  
MINNEAPOLIS, MN  
(612) 546-4221  
800-345-4221  
FAX: (612) 546-4286  
NEW JERSEY  
JAY HILL REPAIRS  
90 CLINTON RD.  
FAIRFIELD, NJ 07004  
(973) 575-9145  
800-836-0643  
GENERAL PARTS, INC.  
MASSACHUSETTS RESTAURANT 11311 HAMPSHIRE AVENUE  
NEBRASKA  
FAX: (973) 575-5890  
SUPPLY  
SOUTH  
GOODWIN - TUCKER GROUP  
34 SOUTH STREET  
SOMERVILLE, MA 02143  
(617) 868-1930  
BLOOMINGTON, MN 55438-2456 7535 D STREET  
GCS SERVICE INC.  
EAST RUTHERFORD, NJ  
(973) 614-0003  
(952) 944-5800  
OMAHA, NE 68124  
(402) 397-2880  
(800) 279-9980  
800-338-6737  
(800) 279-9980 FAX  
800-228-0342  
800-399-8294  
FAX: (617) 868-5331  
FAX: (402) 397-2881  
FAX: (973) 614-0230  
MISSISSIPPI  
GCS SERVICE INC.  
CHELSEA, MA  
(617) 889-9393  
GCS SERVICE INC.  
PHILADELPHIA, PA  
(215) 925-6217  
GCS SERVICE INC.  
JACKSON, MS  
NEVADA  
800-225-1155  
(601) 956-7800  
HI TECH COMMERCIAL SERVICE 800-441-9115  
FAX: (617) 889-1222  
800-274-5954  
FAX: (601) 956-1200  
1840 STELLA LAKE STREET  
NORTH LAS VEGAS, NV 89106  
(702) 649-4616  
(877) 924-4832  
FAX: (702) 649-4607  
FAX: (215) 925-6208  
GCS SERVICE INC.  
HARTFORD, CT  
(860) 549-5575  
ELMER SCHULTZ SERVICES  
201 W. WASHINGTON AVE.  
PLEASANTVILLE, NJ 08232  
(609) 641-0317  
GCS SERVICE INC.  
MEMPHIS, TN  
(901) 366-4587  
800-723-1562  
FAX: (860) 527-6355  
800-262-9155  
800-378-1641  
FAX: (901) 366-4588  
5454 LOUIE LANE  
RENO, NV 89511  
(775) 852-9696  
FAX:(609) 641-8703  
SUPERIOR KITCHEN SERVICE  
INC.  
MISSOURI  
399 FERRY STREET  
EVERETT, MA 02149  
(617) 389-1899  
(888) 590-1899  
(617) 389-1996 FAX  
FAX: (775) 852-5104  
NEW YORK  
GCS SERVICE INC.  
KANSAS CITY, MO  
(816) 920-5999  
800-229-6477  
FAX: (816) 920-7387  
GCS SERVICE INC.  
LAS VEGAS, NV  
(702) 450-3495  
800-500-9060  
FAX: (702) 450-3491  
APPLIANCE INSTALLATION AND  
SERVICE CORP.  
1336 MAIN STREET  
BUFFALO, NY 14209  
(716) 884-7425  
800-722-1252  
FAX: (716) 884-0410  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTER  
NEW YORK TO PENNSYLVANIA  
B.E.S.T. INC.  
AUTHORIZED APPLIANCE  
SERVICECENTER  
904 S. MARSHALL ST.  
WINSTON-SALEM, NC 27403  
(336) 725-5396  
OHIO  
OREGON  
3003 GENESEE STREET  
BUFFALO, NY 14225  
(716) 893-6464  
800-338-5011  
FAX: (716) 893-6466  
CERTIFIED SERVICE CENTER  
890 REDNA TERRACE  
CINCINNATI, OH 45215  
(513) 772-6600  
RON'S SERVICE  
16364 SW 72ND AVE  
PORTLAND, OR 97224  
(503) 624-0890  
FAX:(336) 721-1289  
800-543-2060  
800-851-4118  
AUTHORIZED APPLIANCE  
SERVICECENTER  
104 HINTON AVE.  
WILMINGTON, NC 28403  
(910) 313-1250  
FAX:(910) 313-6130  
FAX: (513) 612-6600  
FAX: (503) 684-6107  
DUFFY'S EQUIPMENT SVC.  
3138 ONEIDA STREET  
SAUQUOIT, NY 13456  
(315) 737-9401  
800-443-8339  
FAX: (315) 737-7132  
CERTIFIED SERVICE CENTER  
171J-K NORTH HAMILTON RD.  
COLUMBUS, OH 43213  
(614) 751-3769  
(866) 862-1252  
FAX: (614) 751-5792  
PENNSYLVANIA  
A.I.S. COMMERCIAL PARTS &  
SERVICE  
1816 WEST 26TH STREET  
ERIE, PA 16508  
(814) 456-3732  
800-332-3732  
WHALEY FOODSERVICE  
8334-K ARROWRIDGE BLVD  
CHARLOTTE, NC 28273  
(704) 529-6242  
FAX: (704) 529-1558  
NORTHERN PARTS & SVC.  
21 NORTHERN AVENUE  
PLATTSBURGH, NY 12903  
(518) 563-3200  
800-634-5005  
FAX: (800) 782-5424  
CERTIFIED SERVICE CENTER  
6025 N. DIXIE DRIVE  
DAYTON, OH 45414  
(937) 898-4040  
(800) 257-2611  
FAX: (937) 898-4177  
FAX: (814) 452-4843  
WHALEY FOODSERVICE  
REPAIRS  
203-D CREEK RIDGE RD.  
GREENSBORO, NC 27406  
(336) 333-2333  
ELMER SCHULTZ SVC.  
540 NORTH 3RD STREET  
PHILADELPHIA, PA 19123  
(215) 627-5400  
FAX: (215) 627-5408  
GCS SERVICE INC.  
BROOKLYN, NY  
(718) 486-5220  
FAX: (336) 333-2533  
COMMERCIAL PARTS & SVC.  
OF COLUMBUS  
800-969-4271  
FAX: (718) 486-6772  
5033 TRANSAMERICA DRIVE  
COLUMBUS, OH 43228  
(614) 221-0057  
800-837-8327  
FAX: (614) 221-3622  
GCS SERVICE INC.  
PHILADELPHIA, PA  
(215) 925-6217  
800-441-9115  
FAX: (215) 925-6208  
WHALEY FOODSERVICE  
REPAIRS  
335-105 SHERWEE DRIVE  
RALEIGH, NC 27603  
(919) 779-2266  
ALL SERVICE KITCHEN  
EQUIPMENT REPAIR  
10 CHARLES ST.  
NEW HYDE PARK, NY 11040  
(516) 378-1176  
FAX: (919) 779-2224  
GCS SERVICE INC.  
COLUMBUS, OH  
(614) 476-3225  
GCS SERVICE INC.  
HARRISBURG, PA  
(717) 564-3282  
FAX: (516) 378-1735  
ALL ISLAND REPAIRS  
40-9 BURT DRIVE  
DEER PARK, NY 11729  
(631) 242-5588  
WHALEY FOODSERVICE  
REPAIRS  
6418-101 AMSTERDAM WAY  
WILMINGTON, NC 28405  
(910) 791-0000  
800-282-5406  
FAX: (614) 476-1196  
800-367-3225  
FAX: (717) 564-9286  
ELECTRICAL APPLIANCE  
REPAIR SVC.  
5805 VALLEY BELT ROAD  
CLEVELAND, OH 44131  
(216) 459-8700  
GCS SERVICE INC.  
PITTSBURGH, PA  
(412) 787-1970  
800-738-1221  
FAX: (412) 787-5005  
FAX: (631) 242-6102  
FAX: (910) 791-6662  
NORTH CAROLINA  
AUTHORIZED APPLIANCE  
SERVICECENTER  
1020 TUCKASEEGEE RD.  
CHARLOTTE, NC 28208  
(704) 377-4501  
NORTH DAKOTA  
800-621-8259  
FAX: (216) 459-8707  
K & D PARTS AND SERVICE CO.  
1833-41 N CAMERON STREET  
HARRISBURG, PA 17103  
(717) 236-9039  
GCS SERVICE INC.  
MINNEAPOLIS, MN  
(612) 546-4221  
OKLAHOMA  
(800) 532-6127  
800-345-4221  
800-932-0503  
FAX:(704) 377-4504  
FAX: (612) 546-4286  
HAGAR RESTAURANT EQMT.  
1229 W MAIN STREET  
OKLAHOMA CITY, OK 73106  
(405) 235-2184  
800-445-1791  
FAX: (405) 236-5592  
FAX: (717) 238-4367  
AUTHORIZED APPLIANCE  
SERVICECENTER  
800 N. PERSON ST.  
RALEIGH, NC 27604  
(919) 834-3476  
GENERAL PARTS, INC.  
10 SOUTH 18TH STREET  
FARGO, ND 58103  
(701) 235-4161  
(800) 279-9987  
(701) 235-0539 FAX  
CLARK SERVICE & PARTS  
306 AIRPORT DRIVE  
BOX 10  
SMOKETOWN, PA 17576  
(717) 392-5590  
FAX:(919) 834-3477  
(717) 392-5735  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS  
RHODE ISLAND TO WISCONSIN  
RHODE ISLAND  
WHALEY FOODSERVICE  
REPAIRS  
4740-A FRANCHISE STREET  
N. CHARLESTON, SC 29418  
(843) 760-2110  
GCS SERVICE INC.  
HOUSTON, TX  
(713)785-9187  
800-868-6957  
FAX: (713) 785-3979  
GCS SERVICE INC.  
VIRGINIA BEACH, VA  
(757) 464-3500  
800-476-4278  
FAX: (757) 464-4106  
GCS SERVICE INC.  
EAST PROVIDENCE, RI  
(401) 434-6803  
800-462-6012  
FAX: (843) 760-2255  
FAX: (401) 438-9400  
GCS/STOVE PARTS  
2120 SOLANA STREET  
FORT WORTH, TX 76117  
(817) 831-0381  
WASHINGTON  
SUPERIOR KITCHEN SERVICE  
INC.  
SOUTH DAKOTA  
GCS SERVICE INC.  
SEATTLE, WA  
669 ELMWOOD AVENUE  
PROVIDENCE, RI 02907  
(888) 590-1899  
GCS SERVICE INC.  
MINNEAPOLIS, MN  
(612) 546-4221  
800-433-1804  
FAX: (817) 834-7754  
(206) 763-0353  
800-211-4274  
FAX: (206) 763-5943  
(401) 781-1996 FAX  
800-345-4221  
FAX: (612) 546-4286  
UTAH  
RESTAURANT APPLIANCE SER-  
VICE  
SOUTH CAROLINA  
GENERAL PARTS, INC.  
10 SOUTH 18TH STREET  
FARGO, ND 58103  
(701) 235-4161  
(800) 279-9987  
(701) 235-0539 FAX  
LA MONICA'S RESTAURANT  
EQMT. SVC.  
6182 SOUTH STRATLER AVENUE (206) 524-8200  
MURRAY, UT 84107  
(801) 263-3221  
800-527-2561  
7219 ROOSEVELT WAY, NE  
SEATTLE, WA 98115  
AUTHORIZED APPLIANCE  
SERVICECENTER  
1811 TAYLOR ST.  
COLUMBIA, SC 29202  
(803) 254-8414  
800-433-9390  
FAX: (206) 525-2890  
FAX: (803) 254-5146  
FAX: (801) 263-3229  
TENNESSEE  
WEST VIRGINIA  
AUTHORIZED APPLIANCE  
SERVICECENTER  
2249 AUGUSTA RD.  
GREENVILLE, SC 29605  
(864) 235-9616  
GCS SERVICE INC.  
MEMPHIS, TN  
(901) 366-4587  
800-262-9155  
FAX: (901) 366-4588  
VERMONT  
STATEWIDE SERVICE, INC.  
603 MAIN AVE.  
NITRO, WV 25143  
(304) 755-1811  
(800) 441-9739  
FAX: (304) 755-4001  
NORTHERN PARTS & SVC.  
4874 S. CATHERINE STREET  
PLATTSBURGH, NY 12901  
(518) 563-3200  
800-634-5005  
FAX: (800) 782-5424  
FAX: (864) 235-9623  
WHALEY FOODSERVICE  
REPAIRS  
I 26&US1  
GCS SERVICE INC.  
NASHVILLE, TN  
(615) 244-8050  
WISCONSIN  
P.O. BOX 4023  
800-831-7174  
WEST COLUMBIA, SC 29170  
(803) 791-4420  
800-877-2662  
FAX: (803) 794-4630  
FAX: (615) 244-8885  
GCS SERVICE INC.  
CHELSEA, MA  
(617)889-9393  
800-225-1155  
APPLIANCE SERVICE CENTER,  
INC.  
2439 ATWOOD AVE  
MADISON, WI 53704  
(608) 246-3160  
TEXAS  
ARMSTRONG REPAIR CENTER FAX: (617) 889-1222  
5110 GLENMOUNT DRIVE  
800-236-7440  
WHALEY FOODSERVICE  
REPAIRS  
HOUSTON, TX 77081  
(713) 666-7100  
VIRGINIA  
FAX: (608) 246-2721  
748 CONGAREE ROAD  
GREENVILLE, SC 29607  
(864) 234-7011  
800-494-2539  
FAX: (864) 234-6662  
800-392-5325  
FAX: (713) 661-0520  
DAUBERS, INC.  
7645 DYNATECH COURT  
SPINGFIELD, VA 22153  
(703) 866-3600  
APPLIANCE SERVICE  
CENTER, INC.  
6843 W. BELOIT RD.  
WEST ALLIS, WI 53219  
(414) 543-6460  
COMMERCIAL KITCHEN REPAIR 800-554-7788  
CO.  
FAX: (703) 866-4071  
1377 N BRAZOS  
P.O BOX 831128  
SAN ANTONIO, TX 78207  
(210) 735-2811  
800-292-2120  
FAX: (210) 735-7421  
800-236-6460  
FAX: (414) 543-6480  
WHALEY FOODSERVICE  
REPAIRS  
1406-C COMMERCE PL.  
MYRTLE BEACH, SC 29577  
(843) 626-1866  
GCS SERVICE INC.  
SILVER SPRING, MD  
(301) 585-7550(DC)  
(410) 792-0388(BALT)  
800-638-7278  
APPLIANCE SERVICE  
CENTER  
786 MORRIS AVE  
GREEN BAY, WI 54304  
(920) 496-9993  
800-236-0871  
FAX: (920) 496-9927  
FAX: (843) 626-2632  
FAX: (301)495-4410  
GCS SERVICE INC.  
DALLAS, TX  
(972) 484-2954  
800-442-5026  
GCS SERVICE INC.  
RICHMOND, VA  
(804) 672-1700  
FAX: (972) 484-2531  
800-899-5949  
FAX: (804) 672-2888  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS  
WISCONSIN TO WYOMING/INTERNATIONAL  
GENERAL PARTS, INC.  
W223 N735 SARATOGA DRIVE  
WAUKESHA, WI 53186  
(262) 650-6666  
(800) 279-9946  
(262) 650-6660 FAX  
WYOMING  
HAWKINS COMMERCIAL APPLI-  
ANCE SERVICE  
3000 S. WYANDOT ST.  
ENGLEWOOD, CO 80110  
(303) 781-5548  
(800) 624-2117  
FAX: (303) 761-5561  
METRO APPLIANCE SERVICE  
1640 S BROADWAY  
DENVER, CO 80210  
(303) 778-1126  
800-525-3532  
FAX: (303) 778-0268  
INTERNATIONAL  
GLOBAL PARTS AND SUPPLY  
7758 NW 72ND ST  
MIAMI, FL 33166  
(305) 885-6353  
H.D. SHELDON AND CO  
19 UNION SQUARE, WEST  
NEW YORK, NY 10003  
(212) 627-1759  
(212) 924-6920  
CANADA  
THE GARLAND GROUP  
1177 KAMATO ROAD  
MISSISSAUGA, ONTARIO L4W  
1X4  
(905) 206-8380  
SALES  
(905) 624-1419  
FAX: (905) 624-1851  
SERVICE  
800-427-6668  
FAX: 800-361-7745  
March 13, 2007  
Delta 5 Installation & Operation Manual 7610-003-37-08  
Issued: 05-25-2007 Revised: 03-08-2013  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Intel Personal Computer DP45SG User Manual
Intel Server S5500HCV User Manual
iSymphony Portable Stereo System B1B User Manual
John Lewis Freezer JLFZW1812 User Manual
JVC Computer Monitor LCT2141 001A H User Manual
JVC DVD Player XV 515GD User Manual
JVC Stereo System CA MXJ900 User Manual
Kenmore Dehumidifier 5751 User Manual
Kenmore Dishwasher 6651378 User Manual
Kenwood Mixer CHEF KM030 User Manual