The lightning flash with arrowhead
symbol, within an equilateral triangle is
intended to alert the user to the presence
of uninsulated “dangerous voltage”
within the product’s enclosure that may
be of sufficient magnitude to constitute a
risk of electric shock to persons.
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
To reduce the risk of electric shock. Do
not remove cover (or back). No user
serviceable parts inside. Refer servicing
to qualified service personnel.
CAUTION:
DT-V24G11Z
DT-V20L3GZ
accompanying the appliance.
INSTRUCTIONS
Table of Contents
MULTI FORMAT LCD MONITOR
Safety Precautions .............................................. 2
IMPORTANT SAFEGUARDS ........................... 2
Installation............................................................ 4
Daily Operations / Connections ......................... 6
Front panel ....................................................... 6
Rear panel........................................................ 8
Available signals............................................. 10
Menu Configuration—MAIN MENU .................. 12
Menu Configuration—SET-UP MENU............... 17
External Control................................................. 21
About the external control .............................. 21
Using the MAKE/TRIGGER system ............... 21
Using the serial communication ..................... 22
Troubleshooting................................................. 24
Self-check program ........................................ 25
Maintenance....................................................... 25
Specifications .................................................... 26
General........................................................... 26
LCD panel ...................................................... 26
Input/output terminals..................................... 26
Dimensions..................................................... 27
The illustration of the monitor is of DT-V24G11Z.
In the case that you use the monitor for many hours, we recommend that you set “NO
SYNC ACTION” in “SYNC FUNCTION” to “P.SAVE” in MAIN MENU. This will reduce power
consumption and relieve strain on the monitor.
For Customer Use:
Enter below the Serial No. which is located on the rear of the cabinet. Retain this information for future reference.
Model No. : DT-V24G11Z / DT-V20L3GZ Serial No. :
LCT2588-002A-H
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING: TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS
APPARATUS TO RAIN OR MOISTURE.
WARNING: THIS APPARATUS MUST BE CONNECTED TO A MAINS SOCKET OUTLET
WITH A PROTECTIVE EARTHING CONNECTION.
CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED.
REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE.
IMPORTANT SAFETY INSTRUCTIONS
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11) Only use attachments/accessories specified by the manufacturer.
12) Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid injury from tip-over.
13) Unplug this apparatus during lightning storms or when unused for long periods of
time.
14) Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed
to rain or moisture, does not operate normally, or has been dropped.
15) Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall
be placed on the apparatus.
FCC NOTICE
CAUTION: Changes or modifications not approved by JVC could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
IMPORTANT RECYCLING INFORMATION
This product has a fluorescent lamp that contains mercury. Disposal of these materials
may be regulated in your community due to environmental considerations. For disposal
or recycling information, please contact your local authorities or for USA, the Electronic
16) Batteries shall not be exposed to excessive heat such as sunshine, fire or the like.
17) When discarding batteries, environmental problems must be considered and the local rules or laws governing
the disposal of these batteries must be followed strictly.
The LCD panel and backlight have life expectancy. Due to the basic characteristics of the LCD panel, an
afterimage or uneven display may occur. It is recommended that you change images occasionally, activate the
power saving function, or often turn off the power to reduce the load on the LCD panel. Charges will apply for
repairs resulting from deterioration due to the passage of time.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Installation
• Do not rest your arm on the monitor or lean against the monitor.
• Do not touch the LCD panel when installing the monitor.
• Be sure to install the monitor securely to prevent the monitor from falling over, which may cause damage to the
monitor or injury.
CAUTION
To detach the stand
CAUTION
Lay the monitor on a cloth with the LCD panel facing down to prevent the LCD panel from being damaged.
Attachment screws
You can place the monitor in the following two ways when using it on the supplied stand.
You can tilt the monitor as follows.
When the stand plate is attached to the higher
position of the stand body (☞ “To adjust the stand
height” on page 5), you can place the monitor as
illustrated below.
Stand body
Screw holes for stand attachment
1 Remove the screws on the right side of the stand
(see the illustration below), then lift the stand up
by about 148°.
Monitor
About 148°
Screw
(silver)
Stand
About 6°
0°
About 6°
Monitor
The illustration of the monitor is of DT-V24G11Z.
2 Attach the removed screws and place the monitor
• When the monitor is not tilted (0°), the
guidelines align as illustrated below.
as illustrated below.
To install the stand
When attaching the stand to the monitor, insert the guides of the stand into the guide holes on the monitor to
place the stand in the correct position. Then fix the stand firmly with the attachment screws.
Guidelines
Guide holes
Guides
The illustration of the monitor is of DT-V24G11Z.
The illustration of the monitor is of DT-V24G11Z.
• You can select the stand height—higher position
or lower position (☞ “To adjust the stand height” on
page 5).
• To place the monitor as illustrated on the left again,
remove the screws on the right side of the stand,
return the monitor angle to 0°, then reattach the
removed screws.
Screw holes
for stand
attachment
CAUTION
CAUTION
• Be careful not to pinch your fingers in the gap
between the monitor and the stand.
• When the stand plate is attached to the lower
position of the stand body, you cannot tilt the
monitor downward.
• When lifting up the stand...
Stand plate
Monitor
– lay the monitor on a cloth with the LCD panel
facing down to prevent the LCD panel from being
damaged.
– be careful not to pinch your fingers in the moving
parts.
• Make sure of lifting the stand up until it stops
(about 148°); otherwise the monitor may fall over.
• Place the monitor on a mat to avoid scratching the
table surface.
Stand body
The illustration of the monitor is of DT-V24G11Z.
• Do not lift up the stand when the stand plate is
attached to the lower position of the stand body.
Download from Www.Somanuals.com. All Manuals Search And Download.
To adjust the stand height
To change the stand height, detach the stand from the monitor (☞ “To detach the stand” on page 4). Then,
change the position of the stand plate according to the stand height you want by choosing the screw holes to use.
To prevent an accidental fall
Fix the monitor to a wall by using strings.
Fixing the monitor
<Higher position>
<Lower position>
Attach the hook (not provided) to the VESA mounting holes on the rear panel (use the two holes on the upper
side) using M4 x 10 mm screws (not provided). Bind the hooks on the rear panel of the monitor to a wall or a pillar
using durable string.
Screw holes for higher position
Screw holes for lower position
VESA mounting holes
Stand plate
Stand plate
Hook and screw (M4 x 10 mm)
(not provided)
Hook (not provided)
The illustration of the monitor is of DT-V24G11Z.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Daily Operations / Connections
7 Front panel
• “NO EFFECT” is displayed when you press a button which is not available for the current input or signal format (the lamp lights even when the function does not
actually work).
Tally lamp
• The items controlled by the MAKE system cannot be controlled by the buttons on the front panel (“REMOTE ON” is displayed and the lamps do not light).
This lamp is controlled by the tally function of the
MAKE/TRIGGER terminal.
• You can select the color of the tally lamp from
“GREEN” or “RED” (☞ “TALLY SELECT” in
“FUNCTION SETTING” on page 17 and “External
Control” on page 21).
5
/
/
/
buttons
p SAFETY MARKER button/lamp
Displays/hides the safety marker.
t INPUT SELECT buttons/lamps
When a menu screen is displayed
Selects or adjusts menu items (☞ “Menu
Operations” on page 7).
Selects an input.
• Adjust the area of the safety marker in “MARKER”
of MAIN MENU (☞ page 13).
SDI 1:
SDI 2:
E. AUDIO HD/SD SDI (IN 1) terminal
E. AUDIO HD/SD SDI (IN 2) terminal
When no menu screen is displayed
Selects the audio channels of EMBEDDED AUDIO
signals (☞ “Audio Channel Selection” on page 7).
• Pressing button while holding button displays
the SET-UP MENU (☞ “Menu Operations” on
page 7).
• This function does not work when displaying the
picture in the 1:1 mode.
• This function does not work when “SAFETY
MARKER” or “R-SAFETY MARKER” is set to
“OFF” in “MARKER.”
DUAL LINK SDI:
E.AUDIO HD SDI (IN 1, IN 2) terminal
DVI: DVI-D (HDCP) terminal
COMPO./RGB: COMPO./RGB terminal
VIDEO 1: VIDEO (INPUT 1) terminal
VIDEO 2: VIDEO (INPUT 2) terminal
• The lamp for the selected input lights.
• When “SDI DUAL LINK” is set to “ON” in MAIN
q SCREENS CHECK button/lamp
Displays only the selected element (R, G, or B) of
the video signal.
6 MENU button
Activates/deactivates the display of the MAIN MENU.
(☞ “Menu Operations” on page 7)
The illustration of the monitor is of DT-V24G11Z.
• Each time you press this button, the picture
changes in the following order.
MENU, press SDI 1 or SDI 2 to select DUAL LINK
(☞ page 12).
1 Speakers (stereo)
7 COLOR OFF button/lamp
y Power lamp
Unlit:
RGB (Normal screen)
Blue screen
Red screen
The speakers emit the same audio signal emitted
from the AUDIO ASSIGN (MONITOR OUT)
terminals (☞ “ 8 AUDIO ASSIGN (MONITOR OUT)
terminals” on page 9).
Displays only the luminance signal.
• This function does not work for RGB input signals.
The monitor is completely off (the power
switch on the rear panel is turned off).
Green screen
8 1:1 button/lamp
w ASPECT button/lamp
Lights in Green:
The monitor is on.
Lights in orange:
The monitor is off (on standby).
Flashes in orange:
The monitor is in the P. SAVE (power
Displays the picture in the original resolution of the
input signal.
• The aspect ratio of the picture may change
depending on the input signal.
Changes the aspect ratio of the picture from 4:3
to 16:9 when the picture of 16:9 aspect ratio is
squeezed into 4:3 format signal.
• To return to 4:3, press the button again.
• This function does not work when displaying the
picture in the 1:1 mode.
2 VOLUME adjustment knob
Adjusts the volume.
3 Picture adjustment knob
PHASE: Adjusts the picture hue.
9 AREA MARKER button/lamp
Displays/hides the area marker.
CHROMA: Adjusts the picture color density.
BRIGHT: Adjusts the picture brightness.
CONTRAST: Adjusts the picture contrast.
• PHASE and CHROMA cannot be adjusted for
certain signal formats.
• When “COMPONENT PHASE” is set to
“DISABLE” and an NTSC signal is input, PHASE
can be adjusted (☞ page 17).
save) mode (☞ “NO SYNC ACTION” in
“SYNC FUNCTION” on page 15).
• Select the style of the area marker in “MARKER”
of the MAIN MENU (☞ page 13).
• This function works only when displaying the
picture in 16:9 aspect ratio.
• This function does not work when “AREA
MARKER” or “R-AREA MARKER” is set to “OFF”
in “MARKER.”
e SCOPE button/lamp
Displays/hides the indication of the wave form
monitor and vector scope (☞
on page 15).
• Each time you press this button, the window
changes in the following order.
u
button
“
SCOPE SETTING
”
Turns on and off (on standby) the monitor.
• The power switch is equipped on the rear panel of
the monitor (☞ 1 on page 8).
No display
Vector scope
r T.C. (time code) button/lamp
Wave form monitor
4 MUTING button
Turns off the sound when no menu screen is
displayed.
• To cancel the function, press the button again or
turn the VOLUME adjustment knob.
• Muting function is also canceled when
“BALANCE” of “AUDIO SETTING” in the MAIN
MENU is changed (☞ page 14).
Activates/deactivates the display of the time data
(time code) contained in the SDI signal (☞ “On the
Information Display” on page 7).
• Select the time code type in “INFORMATION” of
SET-UP MENU (☞ page 19).
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Operations
Audio Channel Selection
On the Information Display
On the Status Display
The monitor displays the information below.
• Make the setting to display/hide each information
using the MENU with the exception of 5,
controlled with T.C. button (☞ r on page 6).
• Select the position of the information display
(☞ “POSITION” in “INFORMATION” on page 19).
Select audio channels emitted from the speakers
(L/R) and the AUDIO ASSIGN (MONITOR OUT)
(OUT1(L)/OUT2(R)) terminals, when EMBEDDED
AUDIO signals come in to the E. AUDIO HD/SD
SDI terminal (IN1 or IN2) and SDI input (1 or 2) is
selected.
• You have to choose a group of selectable audio
channels before the channel selection (☞
“E.AUDIO GROUP” in “AUDIO SETTING” on
page 14).
If you press the INPUT SELECT button (☞ t on
page 6) currently lit, the status of the input signal
and setting of MUTING are displayed for about 3
seconds.
• Make the setting to display/hide the status in
“STATUS DISPLAY” of the “INFORMATION” (☞
page 19).
• When “STATUS DISPLAY” is set to “AUTO” or
“ON,” the status below is also displayed in the
following cases:
1 Display the menu.
To display the MAIN MENU
\ Press MENU button.
To display the SET-UP MENU
\ Press button while holding button.
MAIN MENU
• When a DUAL LINK SDI signal is input, it is
assigned to SDI 1.
• The setting is memorized for each input (SDI 1
and SDI 2).
– When you change the input
– When the signal condition of the current input
changes
Selected item
1 Audio level meter
Operation guide
SET-UP MENU
• Not displayed when “LEVEL METER ch” is set
to “OFF” (☞ “AUDIO SETTING” on page 14).
2 Signal format
– When you turn on the monitor
• When “STATUS DISPLAY” is set to “ON,” the
signal format will remain displayed 3 seconds
after the status is displayed.
1 Press or button when a menu
• Displayed when “STATUS DISPLAY” is set to
“ON” (☞ “INFORMATION” on page 19).
• For the contents displayed, see “Available
signals” and “On the signal format” on page
10.
is not displayed.
The screen for audio channel selection is
displayed.
Selected item
• The screen for audio channel selection
automatically disappears in about 30
seconds after the previous operation.
3 Source name assigned in “CHARACTER
SET.”
Operation guide
1 Signal format
Audio channel selection screen
• Displayed when “SOURCE ID” is set to “ON”
or “AUTO.”
• Displayed in large letters when “STATUS
DISPLAY” is set to “OFF” or “AUTO.”
☞ “INFORMATION” on page 19
4 CRC error indication
• For the contents displayed, see “Available
signals” and “On the signal format” on page
10.
2 Press
buttons to select an item,
then press button.
Selected item
2 Signal format of DVI input or setting of
“COMPO./RGB SEL.”
• For some items, adjustments will be made by
pressing
.
2 Press
buttons to select the left
buttons to select an
☞ “COMPO./RGB SEL.” on page 12, “DVI
INPUT SEL.” on page 20
Status indication of DUAL LINK/3G SDI
signal information
• Displayed when “CRC ERROR” is set to “ON”
(☞ “INFORMATION” on page 19).
• A red square is displayed when an error
occurs.
(L ch) or right (R ch).
3 Press
☞ “NOTE” on page 11
audio channel.
5 Time code
3 Displayed when “SYNC INPUT SEL.” is set
to “EXT.” (external synchronization)
☞ “ SYNC FUNCTION” on page 15
Detailed information of 3G SDI signal input
• Displays the sampling structure/pixel
resolution of the signal format.
• Displayed when the 3G SDI signal is input.
4 Setting of “MUTING”
• Each time you press the button, the audio
channel changes according to the settings of
“E.AUDIO GROUP” (☞ “NOTE” on page 14).
• When the input signal includes no time code,
“TC – –:– –:– –:– –” is displayed (☞ r on
page 6).
Ex.: When “MARKER” in the
MAIN MENU is selected
6 Data format
4 Press MENU button.
The screen for audio channel selection
disappears.
• Displayed when “STATUS DISPLAY” (☞
“INFORMATION” on page 19) is set to “ON”
and SDI signal is input (not all SDI signals) (☞
“CLOSED CAPTION” on page 16).
3 Press
then press
adjustments.
buttons to select an item,
buttons to make
• Displayed only when muting is activated (☞
4 on page 6).
• When any information of 1, 2, 3, 4, or 6
above is displayed while signals come in from
equipment other than a computer, the picture is
displayed without overlapping the information
display area.
Using the audio level meter
4 Press MENU button to finish the
You can check the conditions of the current
EMBEDDED AUDIO signals in the audio level meter
(☞ “On the Information Display” on the right,“LEVEL
METER SETTING” in “AUDIO SETTING” on page 14).
menu operation.
• Pressing MENU button repeatedly
deactivates the display of the menu.
However, the information display will overlap with
the picture when...
– displaying the picture with higher resolution
than the resolution of the panel in 1:1 mode.
– “SD4:3 LARGE” setting is “ON” (☞ “FUNCTION
SETTING” on page 17).
7
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Daily Operations / Connections (cont.)
7 Rear panel
1 POWER switch
Turns AC power on or off.
• You need to press
button (☞ u on page 6) to use the monitor after turning on the POWER switch.
2 AC IN terminal
AC power input connector.
Connect the provided AC power cord to an AC outlet.
• Attach the provided power cord holder to prevent accidental disconnection of the AC power cord (☞
“Attaching the power cord holder” on page 9).
CAUTION
Do not connect the power cord until all other connections are completed.
3 REMOTE terminal
Terminal for controlling the monitor by an external control (☞ “External Control” on page 21).
4 VIDEO (INPUT 1/INPUT 2) terminals (BNC)
Input (IN) and output (OUT) terminals for the composite signals.
5 COMPO./RGB (G/Y, B/PB/B-Y, R/PR/R-Y) terminals (BNC)
Input (IN) and output (OUT) terminals for the analog component (color difference) or analog RGB signals.
• Select the signal type in “COMPO./RGB SEL.” corresponding to the type of the input signal (☞ page 12).
6 EXT.SYNC (CS) terminals (BNC)
Input (IN) and output (OUT) terminals for the external composite sync (Cs) signals.
• To use these terminals, set “SYNC INPUT SEL.” to “EXT.” (☞ “SYNC FUNCTION” on page 15).
• The terminals are for all VIDEO (INPUT 1, INPUT 2) and COMPO./RGB.
• When an external sync signal is input, external synchronization has priority over all VIDEO 1, VIDEO 2 and
COMPO./RGB input.
1 2
7 AUDIO ASSIGN (IN 1/IN 2) terminals (pin jack)
Security slot
Attach a security wire to this slot.
Input terminals for the analog audio signals.
• Use this terminal for the analog audio connection of the SDI. When a superimposed signal (EMBEDDED
AUDIO signal on an SDI signal) is input, analog audio signals cannot be input.
• Select the video input to assign the audio signal in “AUDIO1 ASSIGN.” or “AUDIO2 ASSIGN.” (☞ “AUDIO
SETTING” on page 14).
The illustration of the monitor is of DT-V24G11Z.
Download from Www.Somanuals.com. All Manuals Search And Download.
8 AUDIO ASSIGN (MONITOR OUT) terminals (pin jack)
Attaching the power cord holder
Output terminals for the analog audio signal.
The provided power cord holder prevents accidental disconnection of the AC power cord from the AC IN
terminal.
• The terminals output the audio signal through AUDIO ASSIGN (IN 1 or IN 2) terminals when you select the
video input you have selected for “AUDIO1 ASSIGN.” or “AUDIO2 ASSIGN.” in “AUDIO SETTING” (☞ page
14).
• The power cord holder consists of two parts, a case and a cover.
• The signal is output from this terminal only when the monitor is on or in “P.SAVE” (power save) mode (☞
“NO SYNC ACTION” on page 15).
• The EMBEDDED AUDIO signal...
– is decoded into an analog signal, then emitted.
– is emitted only when “SDI 1” or “SDI 2” is selected, and when EMBEDDED AUDIO signals come in to the
E. AUDIO HD/SD SDI (IN 1 or IN 2) terminal.
1
2
3
To detach the cover
AC IN
terminal
Cover
Case
– has priority over the audio signal input to AUDIO ASSIGN (IN 1 or IN 2) terminals when “SDI-1” or “SDI-2”
is selected for “AUDIO1 ASSIGN.” or “AUDIO2 ASSIGN.” and the EMBEDDED AUDIO signal is input to
E.AUDIO HD/SD SDI (IN 1 or IN 2) terminal.
9 E. AUDIO HD/SD SDI (IN 1, IN 2) terminals (BNC)
Input terminals for the HD/SD SDI signals.
CAUTION
• Use only the provided screws.
• Make sure the plug will not be pulled out after the cover is attached to the case.
• The terminals accept also EMBEDDED AUDIO signals including up to 12 audio channels with a sampling
frequency of 48 kHz.
• Use both terminals when selecting DUAL LINK SDI for the input.
p E. AUDIO HD/SD SDI (SWITCHED OUT) terminal (BNC)
Output terminal for the HD/SD SDI signals.
• The SDI signals of the current input (SDI 1 or SDI 2) are re-clocked, then emitted.
• When an input other than SDI 1 and SDI 2 is selected, the SDI signal of the input selected last time is
emitted from this terminal.
• The signals are emitted from this terminal only when the monitor is on or in “P.SAVE” (power save) mode.
• No signals are emitted when DUAL LINK SDI is selected for the input.
q DVI-D (HDCP) terminal
Input terminal for the DVI-D signal compatible with HDCP.
• When the picture is not displayed correctly, change the setting of “DVI INPUT SEL.” (☞ page 20).
Note for connections
• Before making any connections, turn off all the equipment.
• Use a cord whose plugs correctly match the terminals on this monitor and the equipment.
• Plugs should be firmly inserted; poor connections could cause noise.
• When unplugging a cord, be sure to grasp its plug and pull it out.
• DO NOT connect the power cord until all connections are complete.
• Refer also to the user manual of each piece of equipment.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Daily Operations / Connections (cont.)
7 Available signals The following signals are available for this monitor.
Video signals
Input terminal
E. AUDIO SDI (IN 1, IN 2)*2
Signal format shown in the
status display (☞ page 7)
√: Acceptable
—: Not acceptable
No.
Signal name
NTSC
VIDEO
COMPO./RGB(Analog
DVI-D (HDCP)
(Digital component/Digital RGB)
(INPUT1, INPUT2) component/Analog. RGB)*1
SD/HD (1.5G)
3G SDI
—
—
—
—
—
—
—
—
—
—
—
—
√
DUAL LINK
*1 Analog component/analog RGB
signals are compatible with G on
sync signal, Y on sync signals, and
composite sync signals (CS). The
separate sync signal (HS/VS) is
not compatible.
1
2
3
4
5
6
7
8
9
NTSC
√
—
—
—
—
√
—
—
—
—
—
√
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
√
—
—
—
—
—
—
—
√
PAL
PAL
√
B/W50
B/W50
√
B/W60
B/W60
√
480/60i
480/59.94i
576/50i
480/60p
480/59.94p
480/60i
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
*2 Compatible with EMBEDDED
AUDIO signals.
480/59.94i
576/50i
√
*3 The signal is recognized as
1080/60i, and the status is
displayed as “1080/60i.”
√
√
480/60p
√
—
—
—
—
—
√
*4 The signal is recognized as
1080/59.94i, and the status is
displayed as “1080/59.94i.”
480/59.94p
576/50p
√
√
10 576/50p
√
√
11 640*480/60p
12 640*480/59.94p
13 720/60p
640*480/60p
640*480/59.94p
720/60p
—
—
√
√
√
On the signal format
√
The following messages appear
depending on the type of input
signals and their conditions.
14 720/59.94p
15 720/50p
720/59.94p
720/50p
√
√
√
√
√
√
√
√
16 720/30p
720/30p
√
√
√
—
—
—
—
—
√
When a DVI-D signal protected
with HDCP is input
17 720/29.97p
18 720/25p
720/29.97p
720/25p
√
√
√
\
“*” (at the end of the indication)
When no video signal comes in
\ “NO SYNC”
√
√
√
19 720/24p
720/24p
√
√
√
20 720/23.98p
21 1080/60i
720/23.98p
1080/60i
√
√
√
When a noncompliant video
signal comes in
√
√
√
\ “Out of range”
22 1080/59.94i
23 1035/60i
1080/59.94i
1035/60i
√
√
√
√
√
When “COLOR SYSTEM” (☞
“FUNCTION SETTING” on
page 17) is set to “AUTO” and
the noncompliant composite
video signals come in
\ “OTHERS”
√*3
√*4
√
√
—
—
√
—
—
√
√*3
√*4
√
24 1035/59.94i
25 1080/50i
1035/59.94i
1080/50i
√
√
26 1080/60p
27 1080/59.94p
28 1080/50p
29 1080/30p
30 1080/29.97p
31 1080/25p
32 1080/24p
33 1080/23.98p
34 1080/30psF
35 1080/29.97psF
36 1080/24psF
37 1080/23.98psF
38 1080/25psF
1080/60p
1080/59.94p
1080/50p
1080/30p
1080/29.97p
1080/25p
1080/24p
1080/23.98p
1080/30psf
1080/29.97psf
1080/24psf
1080/23.98psf
1080/25psf
—
—
—
√
—
—
—
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√*3
√*4
√
√*3
√*4
√
√
√
—
—
—
—
—
√
√
√
√
√
√
√
√
—
—
√
√
Download from Www.Somanuals.com. All Manuals Search And Download.
Computer signals (preset)
DVI-D (HDCP) terminals
Specification of the DVI-D (HDCP) terminal
Connect it to the DVI-D output terminal on a personal computer.
Resolution
Frequency
Pin
No.
Pin
No.
Pin
No.
Input signal
Input signal
Input signal
No.
Signal name
Scan system
Horizontal
Horizontal
Vertical
Vertical (Hz)
(kHz)
31.5
31.5
37.9
48.4
47.8
55.9
64.0
65.2
75.0
74.0
45.0
67.5
37.5
56.25
1
2
3
4
5
6
7
8
T.M.D.S Data 2–
T.M.D.S Data 2+
T.M.D.S Data 2 shield
NC
9
T.M.D.S Data 1–
T.M.D.S Data 1+
T.M.D.S Data 1 shield
NC
17
18
19
20
21
22
23
24
T.M.D.S Data 0–
T.M.D.S Data 0+
T.M.D.S Data 0 shield
NC
1
2
3
4
5
6
7
8
9
VGA60
640
852
480
480
59.9
59.9
60.3
60.0
60.0
60.0
60.0
60.0
60.0
60.0
60.0
60.0
50.0
50.0
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
10
11
12
13
14
15
16
WVGA60
SVGA60
800
600
XGA60
1024
1280
1440
1280
1680
1600
1920
1280
1920
1280
1920
768
NC
NC
NC
WXGA (1280)
WXGA+60
SXGA60
768
DDC Clock
DDC Data
NC
+5 V Power
GND
T.M.D.S Clock shield
T.M.D.S Clock+
T.M.D.S Clock–
900
1024
1050
1200
1200
720
Hot Plug Detect
WSXGA+60
UXGA60*5
10 WUXGA60*5
NOTE
11 720/60p
12 1080/60p*5
13 720/50p
Status indication of DUAL LINK/3G SDI signal information
When DUAL LINK and 3G SDI signals come in, the status of DUAL LINK is displayed. When “SDI DUAL
LINK” (☞ page 12) in MAIN MENU is set to “OFF” and a 3G SDI signal comes in, the 3G SDI signal
information is displayed.
1080
720
14 1080/50p*5
1080
*5 For DT-V20L3GZ: When No. 9, 10, 12 or 14 signals come in, thin lines will become obscured because their
signal resolution is higher than the screen resolution.
Status indication of DUAL LINK
• Non-preset signals may not be displayed normally even if their frequency is within the acceptable range (☞
“Horizontal/vertical frequency (computer signal)” on page 26).
• When a preset signal comes in, the signal format is shown on the status display. For other signals, the
resolution is shown.
When “SDI DUAL LINK” (☞ page 12) in MAIN MENU is set to “ON” and an SDI signal is selected, “DUAL
LINK” is displayed.
Status indication of 3G SDI signal information
Following signal information can be displayed when a 3G SDI signal comes in.
3G A-1:
3G A-2:
3G A-3:
3G A-4:
Level A mapping structure 1
Level A mapping structure 2
Level A mapping structure 3
Level A mapping structure 4
3G B-DS1: Level B data stream 1
3G B-DS2: Level B data stream 2
3G B-DUAL: Level B DUAL LINK
11
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Menu Configuration—MAIN MENU
For the operation procedure, see page 7.
PICTURE FUNCTION
Setting for the picture quality
DT-V24G11Z
Item
APERTURE*1
(For DT-V24G11Z)
To do
Setting value
OFF, ON
Activates/deactivates the function at the level set in
“APERTURE LEVEL.”
APERTURE FREQ.*1 Select the frequency of the luminance signal compensated in
OFF, LOW, HIGH
(For DT-V20L3GZ)
“APERTURE LEVEL.”
APERTURE
Compensate the frequency response of the luminance signal of 01 – 10
the video signal.
LEVEL*1
CTI
Adjust the clearness of the outlines of the chrominance signal.
Adjust the clearness of the outlines of the luminance signal.
Selects a proper mode corresponding to the input picture.
OFF, NORMAL,
HARD
LTI
OFF, NORMAL,
HARD
I/P MODE
sub menu
reset
NORMAL, CINEMA,
FIELD
Operation guide
Shows the buttons for each operation.
Display the sub menu which enables you to adjust the items of “PICTURE FUNCTION”
while viewing the actual picture.
Restore the default settings for all the items in “PICTURE FUNCTION.”
*1 Memorized for each input.
Setting value: –20 – +20
DT-V20L3GZ
BACK LIGHT
Adjusts the brightness of the display.
• Adjust according to the ambient light conditions.
Setting value: DS1, DS2
3G SDI LEVEL B
Selects the data stream from two HD SDI signals multiplexed when a 3G SDI level B signal comes in.
Setting value: OFF, ON
SDI DUAL LINK
Activates/deactivates the DUAL LINK function of SDI signals.
• “DUAL LINK” is displayed when the setting is set to “ON.” No other status indications of SDI signals are
displayed.
Operation guide
Shows the buttons for each operation.
• Set this setting to “OFF” when an SDI signal other than DUAL LINK SDI is input.
Setting value: COMPO. (COMPONENT), RGB
COMPO./RGB SEL.
Selects the signal type you want to use for COMPO./RGB terminals.
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
Download from Www.Somanuals.com. All Manuals Search And Download.
MARKER*1*2
Settings for marker functions
1/2
Item
To do
Setting value
AREA MARKER*3
Activate/deactivate the area marker and select the
style of it.
☞ “NOTE”
MARKER ASPECT*3
Select the aspect ratio of the area marker.
4:3, 14:9, 13:9, 2.35:1, 1.85:1,
1.66:1
SAFETY MARKER
Activate/deactivate the safety marker and select
the style of it.
☞ “NOTE”
SAFETY AREA
FRAME
Adjust the area of the safety marker.
80% – 100%
Operation guide
Shows the buttons for each operation.
Displays/hides the frame indicating the area of the OFF, ON
specified aspect ratio.
CENTER MARKER
LINE BRIGHTNESS
Displays/hides the marker indicating the center
position of the picture.
OFF, ON
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
Adjust the brightness of the marker.
HIGH, LOW
2/2
Item
To do
Setting value
R-AREA MARKER*3
Activate/deactivate the area marker and select the
style of it.
☞ “NOTE”
NOTE
R-MARKER ASPECT*3
R-SAFETY MARKER
R-SAFETY AREA
Select the aspect ratio of the area marker.
4:3, 14:9, 13:9, 2.35:1, 1.85:1,
1.66:1
Setting of “AREA MARKER”, “SAFETY MARKER”, “R-AREA MARKER”,
“R-SAFETY MARKER”
The setting values and features are as follows.
OFF:
LINE:
HALF:
HALF+L:
Activate/deactivate the safety marker and select
the style of it.
☞ “NOTE”
Adjust the area of the safety marker.
80% – 100%
Deactivate the marker.
Displays the area with an outline.
• The area marker or the safety marker is displayed by using AREA MARKER or SAFETY MARKER button, or
external control.
• Select either non-“R-” items or “R-” items to activate by using external control (☞ “External Control” on page 21).
• When a picture is displayed in 4:3 aspect ratio, the safety marker for the 4:3 area is displayed.
• To display the safety marker for the area of a picture displayed in 16:9 aspect ratio, hide the area marker
(☞ “NOTE”).
The area outside the specified aspect ratio of the screen is displayed at 50% transparency.
The area of the specified aspect ratio of the screen is indicated by an outline, and the area
outside of that is displayed at 50% transparency.
The area outside the specified aspect ratio of the screen is black. Only the portion of the
picture within the designated area is displayed.
BLK.:
BLK. +L:
The area of the specified aspect ratio of the screen is indicated by an outline, and the area
outside of that becomes black so that only the area inside the line is displayed.
*1 Memorized for each input.
*2 Not displayed when picture is displayed in the 1:1 mode.
*3 Displayed only when picture is displayed in 16:9 aspect ratio.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Menu Configuration—MAIN MENU (cont.)
For the operation procedure, see page 7.
AUDIO SETTING
Settings for the audio output balance, EMBEDDED AUDIO signals and level meter
Item
To do
Setting value
BALANCE
AUDIO1 ASSIGN.
Adjust the balance between the right and left speakers.
L5 – L1, 0, R1 – R5
Select the video input which the audio signal through
AUDIO ASSIGN (IN 1) terminal is assigned to.
SDI-1, SDI-2, DVI, COMP/
RGB, VIDEO-1, VIDEO-2
AUDIO2 ASSIGN.
Select the video input which the audio signal through
AUDIO ASSIGN (IN 2) terminal is assigned to.
E.AUDIO GROUP*1
Select the audio channel group of the EMBEDDED AUDIO
signals.
☞ “NOTE”
☞ “NOTE”
LEVEL METER
Adjust the level meter display for the EMBEDDED AUDIO
signals.
Adjustment bar
SETTING*1
Displayed when selecting
“BALANCE.”
Operation guide
Shows the buttons for each
operation.
LEVEL METER ch Select how the audio channels are displayed on the level
OFF, LINE (Displays
the channels 1 – 6 at
the left of the screen
and 7 – 12 at the right.),
DIVIDE (Displays the odd
channels at the left of
the screen and the even
channels at the right.)
meter.
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
BAR TYPE
Select the color of the level meter display.
3COLORS (3 colors to
indicate variations in input
levels), W.100 (white)
NOTE
REFERENCE
LEVEL
Select the standard input level indicated on the level meter. –20dB, –18dB
Settings of “E.AUDIO GROUP”
The setting values and selectable audio channels of EMBEDDED AUDIO signals are as follows.
OVER LEVEL
Select the input level’s lower limit indicated in red for the
“3COLORS” display.
–10dB, –8dB, –6dB,
–4dB, –2dB
(G means GROUP)
1G:
channel(s) 1/2/3/4/1+2/3+4/1 – 4 (1G)
BAR
BRIGHTNESS
Select the brightness of the level meter.
LOW, HIGH
2G:
channel(s) 5/6/7/8/5+6/7+8/5 – 8 (2G)
1-2G:
3G:
channel(s) 1/2/3/4/5/6/7/8/1+2/3+4/5+6/7+8/1 – 4 (1G)/5 – 8 (2G)/1 – 8 (1G+2G)
channel(s) 9/10/11/12/9+10/11+12/9 – 12 (3G)
PEAK HOLD
Activates/deactivates the peak hold function of the level
meter.
OFF, ON
1-3G:
channel(s) 1/2/3/4/5/6/7/8/9/10/11/12/1+2/3+4/5+6/7+8/9+10/11+12/1 – 4 (1G)/5 – 8 (2G)/
9 – 12 (3G)/1 – 8 (1G+2G)/1 – 12 (1-3G)
*1 Memorized for each input.
Example of the level meter display—Level meter position and audio channels
Ex.: When “LEVEL METER ch” is set to “LINE” and “BAR TYPE” is set to “3COLORS”
OVER LEVEL
REFERENCE LEVEL
Red
Yellow
Green
• The level meter with no audio signal input is displayed in white for “3COLORS”, and in gray for “W.100.”
• You can select the position of the level meter display—top or bottom of the screen (☞ “POSITION” in
“INFORMATION” on page 19).
• When “PEAK HOLD” is set to “ON,” the maximum level meter value will remain displayed for a set period of
time. (At the time the signal input level reaches the highest value.)
Download from Www.Somanuals.com. All Manuals Search And Download.
SCOPE SETTING*1
Settings for the wave form monitor and vector scope
Item
To do
Setting value
–10 – +10
GAIN
Adjust the gain level for the incoming wave form data.
Select the size of the wave form monitor and vector scope window.
SIZE*2
POSITION*2
NORMAL, LARGE
Select the position of the wave form monitor and vector scope
window.
1 (lower right), 2
(lower left), 3 (upper
left), 4 (upper right)
TRANSPARENT Activates/deactivates the function to make the window translucent.
ON (translucent),
OFF (normal)
AUTO OFF
Activates/deactivates the function to make the wave form monitor and ON, OFF
vector scope window go off automatically 15 minutes after displaying it.
WAVE DISPLAY Select the wave form for the wave form monitor.
Operation guide
Shows the buttons for each
operation.
Y/Pb/Pr (HD signals)
Y/Cb/Cr (SD signals)
R/G/B (RGB signals)
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
WAVE FILTER
Activates/deactivates the low-pass filter for the incoming wave form
data.
FLAT (no filter),
LOWPASS
WAVE OVER
LEVEL
Adjust the over level for the incoming luminance (Y) and RGB
signals.
☞ “NOTE”
MARKING
Activates/deactivates the function to change the color of a wave form OFF, ON
when the signal exceeds the limit specified on “LEVEL” (☞ below).
NOTE
LEVEL
Adjust the lower limit for the over level.
070 – 109
*1 Wave form monitor does not work for DVI signals (PC input). Vector scope does not work for RGB signals.
*2 When you set “SIZE” to “LARGE,” the window is displayed in the center of the screen regardress of the “POSITION”
setting.
Example of the vector scope
Ex.: When the color bar is displayed
Example of the wave form monitor
Ex.: When the luminance signal is Y, “MARKING” is set to “ON”
and “LEVEL” is set to “080”
Red
White
SYNC FUNCTION
Settings for the synchronization with signals
Item
To do
Setting value
NO SYNC ACTION Select the screen status when no signal is coming in.
OFF, P.SAVE (power save
mode), GRAY B. (gray screen)
DELAY TIME
Select the period until the screen status changes as selected 30sec., 5min., 15min.
in “NO SYNC ACTION” after signals stop coming in.
SYNC INPUT
Select the sync signal for the VIDEO1, VIDEO2 and
COMPO./RGB input.
INT. (Internal sync),
EXT. (External sync)
SEL.*3
Y
LOW LATENCY
Activates/deactivates the function to shorten the time
taken to display the picture (low latency function).
• If the picture is not displayed steadily while “ON” is
selected, select “OFF.”
ON, OFF
Video signal
Start
End
• While “ON” is selected, the displayed picture may
become unstable when an operation using buttons on
the front panel or the menu is performed, or when the
signal format changes.
• The wave which goes over the value set on “LEVEL” is
indicated in red.
• The display differs depending on the input signal or the
setting of “WAVE DISPLAY.”
• When setting “NO SYNC ACTION” to “GRAY B.,” the screen color changes to gray and the power consumption
of the back light is saved by half. Selecting “P.SAVE” (power save mode) saves more power consumption by
turning off the back light.
• In the initial setting, “NO SYNC ACTION” is set to “P.SAVE”, and “DELAY TIME” set to “15min.” Change the
settings if necessary.
*3 Memorized for each input.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Menu Configuration—MAIN MENU (cont.)
CLOSED CAPTION*1
For the operation procedure, see page 7.
Settings for CLOSED CAPTION functions
Video input (NTSC, B/W60)
Item
To do
Setting value
OFF, ON
CLOSED CAPTION Activate/deactivate the closed caption.
DATA FORMAT
Select the data format of closed caption.
708,
608ANC,
608(708),
608VBI*2
SDI input (DATA FORMAT: 608)
DECODE CH
Selects the type of closed caption.
Selects the type of service block.
CC1, CC2, CC3, CC4,
TEXT1, TEXT2, TEXT3,
TEXT4
SERVICE BLOCK
SERV.1, SERV.2, SERV.3,
SERV.4, SERV.5, SERV.6
Operation guide
Shows the buttons for each
operation.
SDI input (DATA FORMAT: 708)
• CLOSED CAPTION does not work for the video input formats PAL and B/W50.
• CLOSED CAPTION does not work for the COMPO./RGB/DVI input.
• CLOSED CAPTION does not work for the SDI input formats 1035/60i, 1035/59.94i, 1080/60p, 1080/59.94p,
1080/50p and 3G SDI Level A.
• Depending on signal format, there maybe a case that the closed captions are not displayed properly.
• When using the 1:1 mode, closed captions may not be displayed properly.
*1 Memorized for each input.
*2 Displayed only when SD SDI signal is input.
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration—SET-UP MENU
For the operation procedure, see page 7.
FUNCTION SETTING
Settings for the sub menu display, color system, color of the tally lamp, picture size, intensity of the button lamps
and the PHASE adjustment.
Item
To do
Setting value
sub menu
POSI.
Select the contents and displaying position of “sub menu.”
☞ “NOTE”
COLOR
SYSTEM
Select the color system.
• If the picture is unstable with “AUTO,” select “NTSC” or “PAL.”
AUTO, NTSC, PAL
TALLY SELECT Select the color of the tally lamp.
GREEN, RED
☞ “NOTE”
SD4:3 LARGE
DIMMER
Change the picture size of 4:3 format signal.
Select the intensity of the button lamps.
NORMAL, DARK
COMPONENT
PHASE
Deactivates the function of PHASE adjustment (Picture adjustment knob ENABLE, DISABLE
and “PICTURE SUB ADJ.” in SET-UP MENU) except when an NTSC
signal comes in (☞ 3 on page 6).
Operation guide
Shows the buttons for each
operation.
PICTURE SUB ADJ.
Adjusts the standard level for the picture adjustment and selects the set-up level for the input video signal.
Item
CONTRAST*1
To do
Setting value
–20 – +20
Adjust the standard level for the contrast adjusted with the
CONTRAST knob on the front panel.
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
BRIGHT*1
Adjust the standard level for the brightness adjusted with the
BRIGHT knob on the front panel.
–20 – +20
CHROMA*1
PHASE*1, *2
NTSC SETUP
Adjust the standard level for the chroma adjusted with the CHROMA –20 – +20
knob on the front panel.
Adjust the standard level for the phase adjusted with the PHASE
knob on the front panel.
–20 – +20
NOTE
Select the set-up level of the input NTSC signal.
00 (compliant with
0% set-up signal),
7.5 (compliant with
7.5% set-up signal)
Settings of “sub menu POSI.”
The setting values and features are as follows.
COMPO. LEVEL Select the level of the analog component signal (480i and 576i only). B75 (compliant
LOWER1:
UPPER1:
LOWER2:
UPPER2:
Displays the current setting and adjustment bar at the lower part of the screen.
Displays the current setting and adjustment bar at the upper part of the screen.
Displays the current setting at the lower part of the screen.
with BetacamVTR
7.5% set-up signal),
B00 (compliant
with BetacamVTR
0% set-up signal),
SMPTE (compliant
with M2VTR signals)
Displays the current setting at the upper part of the screen.
• The adjustment bar is not displayed for some items.
Settings of “SD4:3 LARGE”
The setting values and features are as follows.
sub menu
reset
Display the sub menu which enables you to adjust the items in “PICTURE SUB ADJ.” while
viewing the actual picture.
OFF:
ON:
Fit the vertical picture size into the pixel numbers of the monitor display.
Fit the vertical picture size into that of the monitor display.
Restore the default settings for all the items in “PICTURE SUB ADJ.”
*1 Memorized for each input.
*2 When “COMPONENT PHASE” is set to “DISABLE” and an NTSC signal is input, PHASE can be adjusted.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Menu Configuration—SET-UP MENU (cont.)
For the operation procedure, see page 7.
SIZE/POSI. ADJ.
Adjusts the size and position of the picture.
Item
H SIZE*1
To do
Setting value
Setting value varies depending on the signals.
Adjust the horizontal picture size.
H POSITION*1 Adjust the horizontal picture position.
V SIZE*1
Adjust the vertical picture size.
V POSITION*1 Adjust the vertical picture position.
sub menu
Display the sub menu which enables you to adjust the items of “SIZE/POSI. ADJ.” while
viewing the actual picture.
reset
Restore the default settings for all the items in “SIZE/POSI. ADJ.”
*1 Memorized for each signal format.
WHITE BALANCE SET.
Selects the GAMMA correction value, color temperature and adjusts the drive level and cutoff point of each color
(R/G/B).
Operation guide
Shows the buttons for each
operation.
Item
To do
Setting value
GAMMA
Select the GAMMA correction value.
2.2 (equivalent to Υ 2.2)
2.35 (equivalent to Υ 2.35)
2.45 (equivalent to Υ 2.45)
2.6 (equivalent to Υ 2.6)
COLOR TEMP. Select the color temperature.
9300K, 6500K, USER
R DRIVE
G DRIVE
B DRIVE*2
Adjust the drive level of each color (red, green, and blue). MIN – 000 – MAX (in 256 grades)
R CUT OFF
G CUT OFF
B CUT OFF*2
Adjust the cutoff point of each color (red, green, and blue). MIN – 000 – MAX (in 256 grades)
sub menu
Display the sub menu which enables you to adjust the items in “WHITE BALANCE SET.” while
viewing the actual picture.
reset
Restore the default settings for the drive levels and cutoff points of the selected color
temperature.
*2 Memorized for each color temperature.
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
Download from Www.Somanuals.com. All Manuals Search And Download.
(☞ “External Control” on pages 21 to 23)
REMOTE SETTING
Settings for the external control
Item
To do
Setting value
SERIAL TYPE
Select the input terminal used for external control by RS232C, RS485
serial communication.
PARALLEL TYPE
Select the external control method for the MAKE/
TRIGGER terminal.
MAKE, TRIGGER, SET
PIN1
PIN2
PIN3
PIN4
PIN5
Assign the control functions to the pins of the MAKE/
TRIGGER terminal.
• Assign a function to each pin terminal by selecting
“SET” in “PARALLEL TYPE” mentioned above.
(The functions are assigned for “PIN6” – “PIN8”
and you cannot change the assignment of these
functions.)
☞ “Functions controlled by the
MAKE/TRIGGER system” on
page 22
Operation guide
Shows the buttons for each
operation.
INFORMATION
Settings for the information display of the monitor
Item
To do
Setting value
POSITION
UPPER, LOWER
Select the position to show the information display (☞ “On the
Information Display” on page 7).
SOURCE ID
Select whether the name assigned in “CHARACTER SET.” is
displayed on the screen (☞ “On the Information Display” on page 7).
• When “AUTO” is selected, the display color synchronizes with the
color of the tally lamp while the tally lamp is lit.
OFF, ON, AUTO
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
CHARACTER
Assign a name to each video source as you like (10 characters at
maximum).You can also enter a name using the RS-232C system.
☞ “NOTE”
SET.*1
STATUS DISPLAY
Select whether the status of the current input and the setting of
MUTING are displayed on the screen (☞ “On the Status Display” on
page 7).
AUTO, OFF, ON
2
TIME CODE
CRC ERROR
Select the type of the TIME CODE display.
VITC
D-VITC
*
2, LTC
*
,
NOTE
Select whether the CRC error indication for the input HD SDI signal is
displayed on the screen (☞ “On the Information Display” on page 7).
ON, OFF
Setting of “CHARACTER SET.”
Assign a name for each video source.
SUB HOUR METER Display the hours of use (unit: hour).You can reset this item.
1 Change the input to one that you want to assign a video source name for.
2 Select “CHARACTER SET.”
MODEL
Display the model name of the monitor.
Display the version of the monitor.
VERSION
HOUR METER
3 Press
buttons to select the first character.
• Each time you press button, the character changes as follows. Press button to reverse the order.
Display the total hours of use (unit: hour). This item is used for maintenance of the
monitor.You cannot reset this item.
Space
*1 Memorized for each input.
*2 Ancillary time code
4 Press button to move the arrow to the next space.
• The characters entered before moving the arrow are memorized.
5 Repeat steps 3 and 4 (10 characters at maximum).
6 Press MENU button to store the name.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
20
Menu Configuration—SET-UP MENU (cont.)
For the operation procedure, see page 7.
Setting value: OFF, VOL.LOCK, ALL LOCK
CONTROL LOCK
Settings for disabling the buttons on the front panel.
• The following operations are not available when “VOL.LOCK” is selected.
– VOLUME adjustment knob
– Picture adjustment knob
• The “ALL LOCK” function disables to control the buttons on the front panel. But following operations are
available.
– Turning on/off (on standby) the monitor
– Displaying the SET-UP MENU (by pressing button while holding button) and turning “CONTROL LOCK”
to “OFF”
– Operating the monitor by an external control
If you try other operations, “
Control lock on!” appears on the screen.
Setting value: AUTO, COMPO., RGB, PC
DVI INPUT SEL.
When “AUTO” is selected, the format of signals come in to the DVI-D (HDCP) terminal is automatically
recognized. (Normally, select “AUTO.”)
• Select “COMPO.,” “RGB” or “PC” when the picture is not displayed correctly with “AUTO.”
• DVI-D input of the monitor is compatible with HDCP.
Operation guide
Shows the buttons for each
operation.
Setting value: AUTO, MS1YCbCr, MS2YCbCr, MS3YCbCr, MS4YCbCr, MS2 RGB, MS3 RGB, 3G-B-DS
SDI FORMAT
• The menu automatically disappears in about 30 seconds after the previous operation.
• Some items may not appear on the menu depending on the input or the input signal.
• The items controlled by the MAKE system do not appear on the menu.
When “AUTO” is selected, 3G SDI/HD-SDI DUAL LINK signals are automatically recognized. (Normally select
“AUTO.”)
• If the picture is unstable with “AUTO”, select the setting value according to the input signal format.
• “M” is displayed on the status display when a setting other than “AUTO” is selected.
all reset
Restores all the settings and adjustments of the monitor to the default.
• “HOUR METER” and the settings done by using the adjustment knobs on the front panel will not be reset.
• After performing “all reset,” the monitor is turned off then turned on automatically.
Download from Www.Somanuals.com. All Manuals Search And Download.
External Control
7 About the external control
7 Using the MAKE/TRIGGER system
This monitor has three external control terminals.
The MAKE/TRIGGER terminal is configured as follows.You can assign a function to each pin terminal in
“REMOTE SETTING” (☞ “PIN1, PIN2, PIN3, PIN4, PIN5” in “PARALLEL TYPE” on page 19).
• You cannot change the functions assigned to the pin terminals from 6th to 8th.
• MAKE/TRIGGER terminal (RJ-45): The following external control systems are available.
(1) MAKE (make contact) system: Controls the monitor by short-circuiting the corresponding pin terminal to
the GND pin terminal, or disconnecting (opening) it.
(2) TRIGGER (trigger) system: Controls the monitor by sending the pulse signal instantaneously to the
corresponding pin terminal.
☞ “Using the MAKE/TRIGGER system” on the right
Pin No.
Pin name
1
2
3
4
5
6
7
8
PIN1
PIN2
PIN3
PIN4
PIN5
TALLY*1
• RS-485 terminals (RJ-45): Controls the monitor with the RS-485 system (☞ “Using the serial communication”
on page 22).
• RS-232C terminal (D-sub 9-pin): Controls the monitor with the RS-232C system (☞ “Using the serial
communication” on page 22).
This is a female terminal.
Set the following items of “REMOTE SETTING” in SET-UP MENU according to the external control terminal and
control system (☞ “SERIAL TYPE,” “PARALLEL TYPE” on page 19).
ENABLE*2
GND
The settings of this unit
Control terminal
Control system
MAKE
“PARALLEL TYPE”
setting
“SERIAL TYPE” setting
*1 The 6th pin terminal controls turning on or off the tally lamp (available to control even when the 7th pin terminal
is invalid).
MAKE/TRIGGER
terminal
—
—
MAKE
TRIGGER
—
*2 The 7th pin terminal makes the external control valid/invalid. Make sure to control the terminal by the MAKE
system.
TRIGGER
RS-485 terminal
RS-232C terminal
Serial
RS-485
RS485*1
RS232C*1
communication
RS-232C
—
To assign the functions to the pin terminals
*1 For a monitor connected to a personal computer etc, select the terminal the equipment is actually connected to.
For other monitors, select “RS485.”
For the operation procedure, see page 7.
1 Select “REMOTE SETTING” on the SET-UP MENU.
Control priority is as follows.
MAKE > TRIGGER = serial communication = buttons and menu on the monitor
2 Set “PARALLEL TYPE” to “SET.”
3 Select a pin name (“PIN1” – “PIN5”) for which you want to assign a function, then select the function you want
to assign.
• You can use external control even when “CONTROL LOCK” is set to “VOL.LOCK” or “ALL LOCK” (☞ page 20).
• When the monitor is off (on standby), external control is not available. But certain external controls (starting/
terminating communication, turning on the monitor) are available through the serial communication (☞ page 23).
• For the selectable functions, see the table on page 22.
<MAKE/TRIGGER system>
Operation of the external control
You can control the monitor by a personal computer or dedicated controller*2.
• “Using the MAKE/TRIGGER system” on the right.
1 Set “PARALLEL TYPE” of “REMOTE SETTING” to “MAKE” or “TRIGGER” in the SET-UP MENU.
2 Short-circuit the 7th pin terminal (ENABLE) to the 8th pin terminal (GND) so that the monitor can be controlled
by the external control.
*2 The controller is not commercially available. Consult your dealer if you need it.
3 When the “MAKE” system is selected: Operate each function by short-circuiting the corresponding pin terminal
<Serial communication>
to the 8th pin terminal (GND) or opening it.
When the “TRIGGER” system is selected: Operate each function by pulse control, that is short-circuiting the
corresponding pin terminal to the 8th pin terminal (GND) for about 1 second and opening it.
PC, etc.
• When changing the input with MAKE system, only one pin terminal must be short-circuited. (Other pin terminals
must be opened.)
• When selecting the “TRIGGER” system, you can operate only one function at a time. Operate the functions one
by one.
RS-485 RS-485
OUT IN
RS-485
OUT
RS-485
IN
RS-485
OUT
RS-485 IN
or
RS-232C
• For the details, see page 22.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
22
External Control (cont.)
*5 While controlling with the MAKE system, the wave form monitor and vector scope is switched between
<Functions controlled by the MAKE/TRIGGER system>
displayed (short-circuting) and hidden (opening) regardless of the “AUTO OFF” setting in the MAIN MANU.
While controlling with the TRIGGER system, the screen is switched in the same way as when pressing the
SCOPE button (☞ e on page 6). If the wave form monitor and vector scope are input at the same time, the
wave form monitor is displayed.
Display
TALLY SEL
Functions to be controlled
Selects the color of the tally lamp.
Changes the input to “SDI 1.”
Changes the input to “SDI 2.”
Changes the input to “DVI.”
Changes the input to “COMPO./RGB”
Changes the input to “VIDEO 1.”
Changes the input to “VIDEO 2.”
Changes the sync signal.
Opening
Green
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Internal sync
DS 1
Short-circuiting
Red
Valid
Valid
Valid
Valid
Valid
Valid
External sync
DS 2
On
SDI 1
*6 While controlling with the MAKE system, the screen is switched between normal screen (opening) and blue
screen (short-circuiting). While controlling with the TRIGGER system, the screen changes in the same way as
when pressing SCREENS CHECK button (☞ q on page 6).
SDI 2
DVI
*7 Must be controlled with the TRIGGER system. The mode changes in the order of “NORMAL”
“FIELD.” (This function cannot be controlled with the MAKE system.)
\
“CINEMA”
\
COMP./RGB
VIDEO 1
VIDEO 2
EXT.SYNC
3G-B.DS
DUAL LINK
A.MARKER
S.MARKER
FRAME
• You cannot assign the same function to different pin terminals.
• The TRIGGER system switches each function by short-circuiting the pin terminal for about 1 second and
opening it.
Selects the “3G SDI LEVEL B” data stream.
Turns on or off “SDI DUAL LINK.”
The area marker indication
The safety marker indication
Indication of the area of the specified aspect ratio
The center marker indication
Selects the items of “MARKER”*1
Changes the aspect ratio.
7 Using the serial communication
Off
You can control the monitor from a personal computer etc. via the RS-485 or RS-232C terminal.
• Consult your dealer for the details of the external control specification.
Off
On
Off
On
<Communication specifications>
Off
On
Input
terminal
Terminal
specification
C.MARKER
MARK.SEL
ASPECT
1:1
Off
On
Cable
Communication specifications
Non-“R-” items
4:3
“R-” items
16:9
RS-485
RS-232C
A straight LAN cable
Baud Rate: 4800 bps
Data Bits: 8 bits
Parity: No parity
Stop Bits: 1 bit
Flow Control: No control
Communication Code: ASCII Code
A straight cable with a D-sub
9-pin connector (male for the
monitor, female for the personal
computer etc.)
Displays in 1:1 mode.
Off
On
☞ See below
STATUS
Status display*2
☞ “On the Status Display” on page 7
3
L.METER
TIME CODE
SOURCE ID
WAVE FORM
VECTOR
C.C.
Audio level meter display
*
Time code display
Off
On
4
5
5
*
*
*
<Specifications of the RS-485 terminal>
Pin No.
☞ “SOURCE ID” in “INFORMATION” on page 19
Wave form monitor display
Vector scope display
IN terminal signal OUT terminal signal
1
2
3
4
5
6
7
8
TXD +
TXD +
TXD –
RXD +
NC
Closed caption display
Off
On
TXD –
RXD +
NC
COLOR OFF
SCR CHECK
I/P MODE
MUTING
DIMMER
– – –
Color off
Color
Monochrome
6
7
Screens check
*
*
Change a mode according to a input picture.
Muting on/off
NC
NC
Off
NORMAL
—
On
DARK
—
RXD –
NC
RXD –
NC
This is a female terminal.
Change the intensity of the button lamps.
No function
GND
GND
*1 Selects which functions in “MARKER” are activated, non-“R-” items or “R-” items (☞ “MARKER” on page 13).
*2 Displays the information shown when INPUT SELECT button of the current input is pressed (☞ “On the Status
Display” on page 7). While controlling with the MAKE system, the information is displayed only at the moment of
short-circuiting.
<Specifications of the RS-232C terminal>
Pin No.
Signal
1
2
3
4
5
6
7
8
9
NC
*3 While controlling with the MAKE system, the level meter is switched between displayed (short-circuiting) and
hidden (opening). When “LEVEL METER ch” is set to “OFF,” the level meter is not displayed (“NO EFFECT”
appears).
RXD
TXD
NC
While controlling with the TRIGGER system, the pattern of the audio channel display is switched.
*4 While controlling with the MAKE system, the available set-up options will be the setting value currently selected
in “SOURCE ID” (“ON” or “AUTO” [short-circuiting]) and “OFF” (opening). While controlling with the TRIGGER
system, uses the same set-up option as those in the SET-UP MENU (☞ “SOURCE ID” in “INFORMATION” on
page 19).
GND
NC
This is a female terminal.
RTS
CTS
NC
• The 7th terminal and the 8th
terminal are connected.
Download from Www.Somanuals.com. All Manuals Search And Download.
<Command outline>
All commands consist of the following segments.
Example of communication procedures
1Starting the communication:
Header
Monitor ID
Command ID
Function
Data
Cr (0Dh)
connection command (!00BCN1Cr)
Monitor
On Header
2Monitor’s status (@00BOKCr)
“!”: Operation commands from the personal computer, etc. For details, see <Basic command list> below.
“?”: Reference commands from the personal computer, etc.
“@”: Status returns from the monitor
3Selecting “SDI 1” input (!00BINACr)
4Monitor’s status (@00BOKCr)
To start communication, send the connection command from the personal computer etc.
To terminate the communication, send the termination command from the personal computer etc.
PC, etc.
5Terminating the communication:
termination command (!00BCN0Cr)
6Monitor’s status (@00BOKCr)
<Basic command list>
No.
1
Commands
Functions
Data
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
**1
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
I
N
N
D
D
D
D
E
P
O
D
D
E
W
W
N
N
N
N
N
N
I
1
0
Cr
Cr
E
Starts communication (connection)
Terminates communication (termination)
x*2 Cr Assigns the control ID
No data
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
2
No data
3
S
R
D
C
N
Cr
W
J
T
T
x
Cr
x
01 – 99
4
I
E
Initializes the control ID
x*2 Cr Displays/hides the ID
No data
5
I
S
P
00: Hide, 01: Display
00: Hide, 01: Display
No data
6
I
H
U
K
x
x*2 Cr Flashes/hides the selected ID No. of the monitor
Displays the MAIN MENU/Quits the menu operation
Moves the cursor upward ( )
7
M
U
D
A
A
S
P
P
I
Cr
8
No data
9
N
R
Cr
Cr
Cr
P
No data
Moves the cursor downward ( )
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Makes setting/adjustment (
Makes setting/adjustment (
Displays the SET-UP MENU
Turns on the monitor
)
)
No data
J
L
No data
T
U
Cr
No data
1
Cr
Cr
Cr
Cr
Cr
Cr
Cr
Cr
P
No data
0
Turns off the monitor (on standby)
Selects “SDI 1” input
No data
A
B
C
D
E
F
No data
I
Selects “SDI 2” input
No data
I
Selects “DVI” input
No data
I
Selects “COMPO./RGB” input
Selects “VIDEO 1” input
Selects “VIDEO 2” input
Displays the status*3
No data
I
No data
I
No data
D
A
A
S
U
P
Cr
E
x*2 Cr
No data
M
S
T
x
x*2 Cr Turns muting on/off
00: Off, 01: On
00: 4:3, 01: 16:9
x
Changes the aspect ratio
• “Cr” is 0Dh.
• The commands for starting communication (connection) (No. 1), terminating communication (termination) (No. 2), and turning on the monitor (No. 13) can be used while the monitor is off (on standby).
*1 Enter the monitor’s ID for “ **.” The initial setting of the monitor’s ID is “00.” When connecting several monitors, “00” is a command for controlling all monitors at once.
*2 Enter the appropriate data to “xx.”
*3 Displays the information shown when the INPUT SELECT button currently lit is pressed (☞ “On the Status Display” on page 7).
23
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Troubleshooting
Solutions to common problems related to the monitor are described here. If none of the solutions presented here
solve the problem, unplug the monitor and consult an authorized dealer or service center.
Symptom
Probable cause and corrective action
Page
Symptom
Probable cause and corrective action
Page
6
8
8
• Adjust the picture contrast or brightness by using the adjustment
knobs on the front panel. Or, adjust “CONTRAST” or “BRIGHT” of
“PICTURE SUB ADJ.” in the SET-UP MENU.
6, 17
• Press the
• Firmly insert the AC power plug.
• Turn on the POWER switch on the rear panel.
button.
The picture becomes
blurred.
No power supply
• Check whether the setting of 1:1 or ASPECT buttons is appropriate.
• Check whether the input signal format is acceptable on the monitor.
Wrong picture position, • Adjust the picture size (H SIZE/V SIZE) or position (H POSITION/V
6
• Select the correct input using the INPUT SELECT buttons.
• Connect the signal cable firmly.
• Turn on the power of the connected component and set the output
correctly.
6
8
—
10, 11
18
No picture with the
power on
wrong picture size.
POSITION) of “SIZE/POSI. ADJ.” in the SET-UP MENU.
• For some signals, the picture cannot be displayed fully in the effective
screen area. There is no sure method to solve this problem.
—
—
• Check whether the input signal format is acceptable on the monitor.
10, 11
• Adjust the volume level.
6
6
8
• The items which are not available for the current input or the current
input signal are not displayed on the menu. Change the input or the
input signal.
• The items controlled by the MAKE system do not appear on the
menu.
• Deactivate the muting function.
• Connect the signal cable firmly.
• Turn on the power of the connected component and set the output
correctly.
No sound
Some items do not
appear on the menu.
—
21
“OTHERS” or “Out of
range” appears.
• Check whether the input signal format is acceptable on the monitor.
10, 11
• Set “CONTROL LOCK” in the SET-UP MENU to “OFF.”
• You cannot use the buttons for the items controlled by the MAKE
system. Disable the external control.
20
21, 22
Buttons on the monitor
do not work.
• Select the correct input using the INPUT SELECT buttons.
• Connect the signal cable firmly.
6
8
• Turn on the power of the connected component and output video
signals. Or, check whether the video output of the component (video
output setting of the VCR or graphic board of the computer) is set
correctly.
—
“NO SYNC” appears.
• Adjust each picture adjustment knob on the front panel or adjust the
items of “PICTURE SUB ADJ.” in the SET-UP MENU. Or, perform
“reset” in “PICTURE SUB ADJ.”
6, 17
• Check whether the setting of COLOR OFF or SCREENS CHECK
buttons are appropriate.
6
Wrong color, no color
• Select the proper color system (“COLOR SYSTEM”) in “FUNCTION
SETTING” of the SET-UP MENU.
• Adjust the items of “WHITE BALANCE SET.” in the SET-UP MENU.
Or, perform “reset” in “WHITE BALANCE SET.”
17
18
The following are not malfunctions.
• When a still image is displayed for a long time, it may remain indistinctly on the screen after the picture has
changed. Though the remaining picture will disappear after a while, there may be a case that it remains
for a long period depending on the length of time the still image was displayed for. This is due to the
characteristics of the LCD display and is not a malfunction.
• Red spots, blue spots and green spots on the panel surface are a normal characteristic of LCD displays,
and not a problem. The LCD display is built with very high precision technology; however, be aware that a
few pixels may be missing or constantly lit.
• The following symptoms are problems only when pictures or sounds are not played back normally.
– A slight electric shock occurs when you touch the monitor.
– The top and/or rear panel of the monitor becomes hot.
– The monitor emits a cracking noise.
– The monitor emits a mechanical noise.
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
Troubleshooting (cont.)
Unplug this product from the wall outlet before cleaning.
7 Self-check program
This monitor has a self-check function, which allows it to detect malfunctions and alert you. This makes
troubleshooting easier. Whenever a problem occurs, one or some of the INPUT SELECT lamps will flash. If this
happens, follow the steps below and contact your dealer to resolve the problem.
Screen
To avoid irreparable change in appearance of the screen such as uneven color, discoloration, scratches, be
careful about the following:
• Do not paste or stick anything using any glues or adhesive tapes.
• Do not write anything on the screen.
• Do not strike the screen with a hard object.
• Avoid condensation on the screen.
• Do not wipe the screen with solvent such as alcohol, thinner, or benzine.
• Do not wipe the screen forcefully.
Wipe stains off the screen with a soft cloth. If the screen gets heavily stained, wipe it with a soft cloth soaked in
water-diluted neutral detergent and wrung well, then wipe with a soft dry cloth.
Cabinet
To avoid the deterioration or damages of the cabinet such as its paint’s peeling away, be careful about the
following:
• Do not wipe the cabinet using solvent such as alcohol, thinner, or benzine.
• Do not expose the cabinet to any volatile substance such as insecticides.
• Do not allow any rubber or plastic in contact for a long time.
• Do not wipe the cabinet forcefully.
The illustration of the monitor is of DT-V24G11Z.
Wipe stains off the cabinet with a soft cloth. If the cabinet gets heavily stained, wipe it with a soft cloth soaked in
water-diluted neutral detergent and wrung well, then wipe with a soft dry cloth.
When the screen goes blank, and one or some of the INPUT SELECT lamps (COMPO./RGB, VIDEO1,
VIDEO2) on the front control panel start flashing...
Ventilation openings
Use a vacuum cleaner to get rid of the dust around the intakes (all the openings). If a vacuum cleaner is not
available, use a cloth and wipe it off. Leaving the dust around the intakes may prevent proper temperature control
and cause damage to the product.
1 Check which lamps are flashing.
2 Press
button to turn off (on standby) the monitor.
3 Turn off the power switch on the rear panel.
4 Disconnect the AC power cord from the AC outlet.
5 Contact your dealer with the information about which lamps were flashing.
• If you turn on the monitor soon after turning it off (or after a short-term power failure), the INPUT SELECT
lamps may flash and no image may be displayed.
When this happens, turn off power and wait at least 10 seconds before turning on the monitor again.
If the INPUT SELECT lamps do not flash, you can use the monitor as normal.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
26
Specifications
7 General
7 LCD panel
Model name
DT-V24G11Z
DT-V20L3GZ
Type 20 wide format
Model name
Type
DT-V24G11Z
DT-V20L3GZ
Type
Multi format LCD monitor
Type 24 wide format
16:10
24˝ wide, active matrix TFT
20˝ wide, active matrix TFT
Screen size
Aspect ratio
Effective screen size
Width:
518.4 mm (20 1/2˝)
Height: 324 mm (12 7/8˝)
Width:
433.4 mm (17 1/8˝)
Height: 270.9 mm (10 3/4˝)
Number of pixels displayed
Number of colors displayed
Viewing angle (TYP.)
Brightness (TYP.)
1 920 x 1 200
1 680 x 1 050
Horizontal/vertical frequency
(computer signal)
H: 31.469 kHz – 75.000 kHz
V: 48 Hz – 65 Hz
16.77 million
* Some signals within this frequency range may not be displayed (“Out of
range” is displayed).
178° (Horizontally), 178° (Vertically)
400 cd/m2
178° (Horizontally), 178° (Vertically)
470 cd/m2
Compliant video signal format
Format
☞ “Available signals” on page 10
Contrast ratio (TYP.)
1000:1
700:1
3G SDI: SMPTE424M/SMPTE425M
DUAL LINK HD SDI:
SMPTE372M
7 Input/output terminals
HD SDI: BTA S-004C, SMPTE292M
SD SDI: ITU-R BT.656: 525/625
SMPTE259M: 525
EMBEDDED AUDIO:
SMPTE299M, SMPTE272M
CLOSED CAPTION:
Model name
DT-V24G11Z
DT-V20L3GZ
VIDEO (INPUT 1)
Input/output of composite signal:
2 line, BNC connector x 4,
1 V(p-p), 75 Ω
VIDEO (INPUT 2)
DVI-D (HDCP)
* The input (IN) and output (OUT) terminals are bridge-
connected (auto termination).
EIA/CEA-608, EIA/CEA-708
Audio output
Internal speaker: 1.0 W + 1.0 W
DVI-D signal input (compatible with HDCP):
DVI-D connector x 1 (compatible with DDC2B)
Operating conditions
Operating temperature: 5°C – 35°C (41°F – 95°F)
Operating humidity: 20% – 80% (non-condensing)
(Slightly variable depending on ambient conditions for installation.)
COMPO./RGB (G/Y, B/PB/B-Y, Input/output of analog component signal/analog RGB signal:
R/PR/R-Y)
1 line, BNC connector x 6
Power requirements
Rated current
AC 120 V, 50 Hz/60 Hz
G/Y: 1 V(p-p), 75 Ω (including sync signal)
B/PB/B-Y, R/PR/R-Y: 0.7 V(p-p), 75 Ω
* The input (IN) and output (OUT) terminals are bridge-
connected (auto termination).
1.15 A
1.00 A
External dimensions
(excluding protruding parts)
Width:
Width:
564 mm (22 1/4˝) 564 mm (22 1/4˝)
477 mm (18 7/8˝) 477 mm (18 7/8˝)
Height:
394.6 mm (15 5/8˝) 354 mm (14˝)
Depth:
243 mm (9 5/8˝)
EXT.SYNC (CS)
Input/output of composite sync signal:
Height:
1 line, BNC connector x 2,
0.3 V(p-p) – 4 V(p-p),
75 Ω (tri-level sync, negative polarity sync (bi-level), and BB)
(including no video signal)
* The input (IN) and output (OUT) terminals are bridge-
connected (auto termination).
448.6 mm (17 3/4˝) 408 mm (16 1/8˝)
Depth:
243 mm (9 5/8˝)
99 mm (4˝)
99 mm (4˝)
(with the stand)
(without the stand)
(with the stand)
(without the stand)
Weight
11.5 kg (25.3 lbs) (with the stand)
8.6 kg (18.9 lbs) (without the stand)
10.6 kg (23.3 lbs) (with the stand)
7.7 kg (16.9 lbs) (without the stand)
E. AUDIO HD/SD SDI (IN 1)
E. AUDIO HD/SD SDI (IN 2)
Digital signal input (compatible with EMBEDDED AUDIO/DUAL LINK signals):
auto detection, 2 line, BNC connector x 2
Accessories
AC power cord, Power cord holder x 1, Screw x 2 (for power cord holder)
E. AUDIO HD/SD SDI
(SWITCHED OUT)
Digital signal output (compatible with EMBEDDED AUDIO signals):
1 line switched out, BNC connector x 1
Notice on transportation
This monitor is precision equipment and needs dedicated packing material for transportation.
Never use any packing material supplied from sources other than JVC or JVC-authorized dealers.
AUDIO ASSIGN (IN 1)
AUDIO ASSIGN (IN 2)
Analog audio signal input:
2 line, RCA connector x 4,
500 mV (rms), high impedance
AUDIO ASSIGN
(MONITOR OUT)
Analog audio signal output: 1 line, RCA connector x 2,
500 mV (rms)
• For easy understanding, pictures and illustrations are shown by being emphasized, omitted or composed,
and may be slightly different from actual products.
• Design and specifications are subject to change without notice.
• All company names and product names mentioned herein are used for identification purposes only, and
may be the trademarks or registered trademarks of their respective companies.
REMOTE (MAKE/TRIGGER)
REMOTE (RS-485)
☞ “Using the MAKE/TRIGGER system” on page 21
☞ “Using the serial communication” on page 22
REMOTE (RS-232C)
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications (cont.)
Unit: mm (inch)
7 Dimensions
DT-V24G11Z
<Front view>
<Side view>
<Rear view>
99 (4)
51.9 (2 1/8)
1.3 (1/16)
VESA mounting holes
(Size: 4-M4, depth: 10 mm)
564 (22 1/4)
100
51 (2 1/8)
300 (11 7/8)
243 (9 5/8)
DT-V20L3GZ
<Front view>
<Side view>
<Rear view>
99 (4)
52.7 (2 1/8)
1.3 (1/16)
VESA mounting holes
(Size: 4-M4, depth: 10 mm)
477 (18 7/8)
100
51 (2 1/8)
300 (11 7/8)
243 (9 5/8)
* at the higher position
**at the lower position
27
Download from Www.Somanuals.com. All Manuals Search And Download.
DT-V24G11Z/DT-V20L3GZ MULTI FORMAT LCD MONITOR
© 2011 Victor Company of Japan, Limited
0111TMH-MW-MT