101M 101M
air purifier with uv light
’
owners guide
TP101Mb040808
Download from Www.Somanuals.com. All Manuals Search And Download.
2
3
safeTy insTrucTions
iMPorTanT warnings
Uv Lamp Notice
UV light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision.
Never look directly at the UV lamp while it is illuminated-doing so could cause loss of vision!
Only view illumination through the window at the front of the unit. To prevent exposure to
ultraviolet light, disconnect the power to the unit before servicing any part of the Therapure™ 101
air purifier.
READ & SAvE THESE INSTRUCTIONS
WARNING: RISK OF ELECTRICAL SHOCK
Safety precautions should always be used when operating this or any electrical appliance.
Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the
warnings below.
Mercury Notice
Use only as described in this Therapure® manual. To reduce the risk of electric shock, do
not attempt to service the product in any way other than in the manner described in the
“Cleaning & Maintenance” section of this manual.
This device contains mercury in the sealed ultraviolet lamp(s). Do not place your used lamp(s) in the
trash. Disposal of any item containing mercury must be in accordance with any hazardous waste
disposal or recycling laws and regulations of your state.
READ ALL INSTRUCTIONS BEFORE OPERATING THE AIR PURIFIER.
Uv Lamp Disposal
»
»
»
This product operates at 120VAC, 60Hz only.
If the UV lamp breaks, turn off the unit. Do not operate the unit with a broken lamp. Do not use a
vacuum to clean up breakage. Sweep debris into a plastic bag and dispose of properly. Contact your
local waste management authority for instructions regarding recycling and the proper disposal of
Do not run power cord under carpets, and do not cover with throw rugs.
Do not operate the product in any greasy environment such as in the kitchen. This product is
not intended to filter oil or grease from air.
»
»
Do not use the Therapure® 101 air purifier in bathrooms or other humid environments, near
fireplaces or in areas where flammable or combustible vapors or products may exist.
Always unplug the power cord from electrical socket when the purifier is not in use, before
cleaning, inserting or removing parts or before moving to another location.
»
»
Never run air purifier unless it is fully assembled.
To reduce the risk of electric shock, this product has a polarized plug (one blade is wider than
the other). This plug will fit into a polarized outlet only one way. If the plug does not fit into the
outlet, contact qualified service personnel to install the proper outlet. Do not alter the plug in
any way.
»
»
Always turn off all controls before unplugging the Therapure® 101 air purifier from outlet.
Attempting to service the Therapure® 101 air purifier in any way that is not described in this
owner’s manual will cause the warranty to be voided and could cause serious personal injury to
the user and/or result in considerable damage to the unit.
»
»
Do not place the cord near a heated surface.
Never operate the Therapure® 101 air purifier if the plug or cord is damaged or appears damaged.
Only qualified service personnel should ever replace or attempt to replace a damaged power cord.
»
Never use the power cord to pick up, carry, drag, pull, or lift the Therapure® 101 air purifier. Do
not pull the cord against or around sharp corners and edges. This could result in injury to the
user or damage to the cord.
»
»
»
Always remove the plug from its power outlet by holding onto the plug itself and pulling gently.
Never pull on the cord itself to unplug it from its power outlet.
Use care when operating the Therapure® 101 air purifier by keeping all foreign objects, fingers,
body parts, hair, loose clothing and jewelry away from openings.
»
»
Never touch the Therapure® 101 air purifier or its plug when your hands are wet.
The Therapure® 101 air purifier is an electrical appliance. Adult supervision is required when
operating the Therapure™ 101 in the presence of children.
»
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any
solid-state speed control devices.
101M
Download from Www.Somanuals.com. All Manuals Search And Download.
4
5
ProducT benefiTs
Triple action purification:
Main ParTs
1. Permanent HEPA Type Filter: the permanent filter removes small visible and non-visible
particles down to 0.1 microns in size.
1. Permanent HEPA type Filter takes particles out of the air, purifying it.
2. UV lamp kills germs, such as viruses and bacteria.
2. 3-Speed Settings: there are 3 speed settings: low, medium and high for you to choose
according to the air quality needs in the room.
3. Photo catalyst filter removes VOCs (volatile organic compounds) from the air,
including toxic fumes and chemicals such as paint and new carpet fumes.
3. Uv Lamp Button: the germicidal UV light is used to kill harmful airborne bacteria,
germs and viruses.
»
»
Effectively removes smoke, pollen, dust, animal dander, dust mites, mold and bacteria.
3 speed fan setting–lets you select the desired cleaning level.
4. Locking Latch
5. Air Inlet Grill
6. Air Outlet Grill
7. Uv Lamp view Window
8. Base of Unit
9. Uv Lamp Access
101M
Download from Www.Somanuals.com. All Manuals Search And Download.
6
7
®
oPeraTingTheTheraPure 1 0 1 M
®
oPeraTingTheTheraPure 1 0 1 M
Before using your Therapure® 101 air purifier, please read the following important information.
Electrical Ratings:
Controls/Settings
There is an OFF button and a Speed Knob on the Control Panel. Just turn the Speed Knob
to the setting you want.
120V Setting: 120Vac, 60 Hz
Power consumption: 38 watts at high fan speed,
3 watt UV light bulb
Net weight: 6.5 lbs.
Dimension (LxWxH): 10” x 7.5” x 16”
OFF
–turns unit off.
LOW –at this setting, the unit will run at low speed.
MED –at this setting the unit will run at medium speed.
HI
–at this setting the unit will run at high speed.
Replacement Parts:
Lamp – TPP1010
Filter – TPP1011
Press the UV lamp button to turn on the UV lamp to kill harmful airborne
bacteria and germs. Press it again to turn off the UV lamp.
Safety
1. Do not blow air directly into air purifier.
2. Keep both sides of the unit at least 1 foot away from a wall.
3
Do not place the unit near curtains.
4. Placing the unit close to the source of air pollution is an effective way to improve
indoor air quality.
1.
2.
3.
4.
Locate a level surface on which to place your Therapure® 101 air purifier and a 120V outlet (follow
warnings in the “SAFETY INSTRUCTIONS”, “IMPORTANT WARNINGS” sections of this manual).
Position your Therapure® at least one foot (12 inches) from the wall. Plug in the unit. You are now
ready to turn on your Therapure® 101 air purifier!
101M
Download from Www.Somanuals.com. All Manuals Search And Download.
8
9
oPeraTion
To operate your Therapure® 101 air purifier, rotate the Speed Knob to the speed of your choice to
activate your air purifier. There are three speed settings controlled by the Speed Knob. The different
settings are LOW, MED and HI. Turn the Speed Knob to rotate through the settings and select the
setting you desire.
cleaning&MainTenance
With very little effort, the Therapure® 101 air purifier delivers cleaner, fresher, sanitized air to your
indoor environments.
Keep your Therapure® 101 functioning properly by cleaning the Permanent HEPA type Filter. More
frequent cleaning will be necessary if the unit is located in an area with a high level of airborne
contaminants (excessive amounts of smoke, pet dander, etc.).
Your Therapure® 101 air purifier has triple action purification. First, the Permanent HEPA type Filter
removes pollutants such as dust, pollen, smoke and pet dander from the air. Second, the powerful
UV technology kills airborne germs, bacteria, viruses, mold and mildew. Third, the photo catalyst
filter removes odors and toxic chemicals and fumes.
Exposing your Therapure® to candle/oil/fireplace soot and smoke is not recommended and will
require more frequent cleaning.
Remember: Always make sure your air purifier is turned off and unplugged before cleaning.
Cleaning the Permanent HEPA type Filter
a. Clean the Permanent HEPA type Filter after each month of use.
b. Be sure to turn off and unplug the unit before cleaning.
1. Release the inlet grill by pressing on the Locking Latch (see diagram of Main Parts).
2. Remove the inlet grill from the unit as shown below.
3. Grasp the left and right frames of the Permanent HEPA type Filter through the indentations on
the sides of the filter enclosure and remove the filter.
4. To clean the Permanent HEPA type Filter, use the brush attachment with your vacuum cleaner.
Run the attachment along the inlet and outlet side of the filter, cleaning between the crevices as
much as possible. Do not use water or any household cleaners or detergents to clean the
Permanent HEPA type Filter.
1.
2.
Control Panel
3.
4.
101M
Download from Www.Somanuals.com. All Manuals Search And Download.
10
11
cleaning&MainTenance
NOTE:
cleaning&MainTenance
Before replacing the Uv lamp, make sure your Therapure® air purifier
is turned off and unplugged.
» vacuuming will restore performance of the Permanent HEPA type Filter. However, the
filter may appear stained. This is normal and does not affect performance in any way.
Replacing the Uv Lamp:
» Do not use water or any household cleaners or detergents to clean the Permanent HEPA
type Filter.
1. Take out the screw from the bottom cover (see Figure 1.). Rotate the cover
counter-clockwise to remove the cover.
» The Permanent HEPA type Filter has been designed to never need replacing. However, it
does need servicing. We recommend that under normal conditions of continuous use, the
filters be cleaned every month to maintain optimal functioning.
2. Pull out the lamp base assembly by rotating the assembly counter-clockwise to unlock.
3. Pull out the old UV lamp from the lamp base assembly.
4. Install the new UV lamp into the lamp base assembly.
5. Insert the UV lamp base assembly into the unit. Make sure the UV lamp base assembly snaps
into place. Turn the base clockwise to lock it in.
6. Replace the cover (rotate cover clockwise) and the screw.
» The inlet grill may be cleaned (after unit is turned off and unplugged) with a vacuum
or a slightly damp cloth.
Uv lamp
1.
3.
5.
2.
4.
6.
The lifetime of the UV lamp is up to 18 months of continuous, effective operation. After this time,
the bulb may remain illuminated, but its effectiveness is greatly reduced. For maximum germicidal
protection, please replace the UV bulb annually.
If the lamp stops functioning, please call 1.800.875.8577 to order a replacement lamp.
Cleaning External Surfaces
O
C
N
K
1. Turn off and unplug unit.
2. Use a washcloth slightly dampened with a little water and dishwashing soap to wipe
the outer case surfaces.
3. Do not allow water to slip into the internal parts as this could damage your unit and result
in electrical shock and injury to you.
4. Allow the unit to thoroughly dry before use.
O
C
N
K
101M
Download from Www.Somanuals.com. All Manuals Search And Download.
12
13
TroubleshooTing
PROBLEM
one-yearliMiTedwarranTy
ONE YEAR LIMITED WARRANT Y
REASON
SOLUTION
Your Therapure® 101 air purifier is warranted to be free from defects in materials and workmanship
for one year from the original purchase date, excluding the lamp. Should the product have a defect
in materials or workmanship, we will repair or replace it without charge to you (a shipping and
processing fee may apply). To obtain service under warranty, simply call our Customer Service
Center toll-free at 1.800-554-6168.
Unit will not operate.
Speed Knob has not been
turned on.
Turn on Speed Knob.
This warranty does not cover any damage caused by accident, misuse or any use other than as
intended and described in this owner’s guide, or damage resulting from failure to maintain and clean
this product as specified in this product manual. This warranty applies only to the original purchaser
of the Therapure® 101 air purifier.
Unit is unplugged.
Check to ensure unit
is plugged in.
The inlet grill has not been
installed & locked into place.
Check to mke sure filters
are properly installed & locked
into place.
Contact Info for Warranty Service:
Ionic Pro
|
| 90028
P.O. Box 4135 Hollywood, CA
The UV lamp cover has
not been installed or locked
in place.
Check to make sure the cover
is properly installed and locked
into place.
|
©2007-2008 Ionic Pro, LLC. All Rights Reserved.
Reduced airflow or
poor filtering.
The inlet or outlet grill may
be blocked.
Check to ensure nothing is
blocking air inlet & air outlet.
Permanent filter may
be clogged.
Check & clean filter,
if necessary.
UV button is not turned on.
UV lamp is broken.
Check that the UV button
is turned on.
No visible light in the
Uv light view window.
Replace the UV lamp.
101M
Download from Www.Somanuals.com. All Manuals Search And Download.
14
15
arbiTraTion agreeMenT
uVlaMPrePlaceMenTschedule
THIS ARBITRATION AGREEMENT (“AGREEMENT”) AFFECTS YOUR LEGAL RIGHTS AND REMEDIES BY
PROVIDING THAT DISPUTES BETWEEN YOU AND THE SELLER OF THIS PRODUCT (“COMPANY”), MUST
BE RESOLVED THROUGH BINDING ARBITRATION, RATHER THAN IN A COURT. PLEASE READ THIS
AGREEMENT CAREFULLY. YOU ACCEPT THE TERMS OF THIS AGREEMENT BY RETAINING THE PRODUCT(S)
SHIPPED IN CONNECTION WITH THIS AGREEMENT (THE “PRODUCT”) FOR MORE THAN FOURTEEN (14)
DAYS AFTER RECEIPT. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, YOU MAY RETURN
THE PRODUCT TO COMPANY WITHIN FOURTEEN (14) DAYS OF RECEIPT AT NO COST TO YOU.
We recommend that you replace the Uv lamp on an annual basis.
UV lamp replaced on:
Purchased at:
1. RESOLUTION OF CLAIMS OR DISPUTES.
Any claim or dispute between you and Company (or any of Company’s subsidiaries or affiliates) arising out
of or relating in any way to the Product or this Agreement shall be resolved through final, binding arbitration.
This arbitration obligation applies regardless of whether the claim or dispute involves a tort, fraud,
misrepresentation, product liability, negligence, violation of a statute, or any other legal theory. Both you
and Company specifically acknowledge and agree that you waive your right to bring a lawsuit based on such
claims or disputes and to have such lawsuit resolved by a judge or jury.
UV lamp replaced on:
Purchased at:
2. LIMITATION OF LEGAL REMEDIES.
All arbitrations under this Agreement shall be conducted on an individual (and not a class-wide) basis, and an
arbitrator shall have no authority to award class-wide relief. You acknowledge and agree that this Agreement
specifically prohibits you from commencing arbitration proceedings as a representative of others or joining in
any arbitration proceedings brought by any other person.
UV lamp replaced on:
Purchased at:
3. ARBITRATION PROCEDURES.
a. Before commencing any arbitration proceedings under this Agreement, you must first present the claim or
dispute to Company by calling 818.217.2500 and asking for the Legal Department and allowing Company the
opportunity to resolve the claim or dispute. If your claim or dispute is not resolved within sixty (60) days, you
may commence arbitration proceedings in accordance with the terms of this Agreement.
b. The arbitration of any claim or dispute under this Agreement shall be conducted pursuant to the
American Arbitration Association’s (“AAA”) United States Commercial Dispute Resolution Procedures and
Supplementary Procedures for Consumer-Related Disputes. These rules and procedures are available by
UV lamp replaced on:
Purchased at:
c. The arbitration of any claim or dispute under this Agreement shall be conducted in the State of
California or the location in which you received this Agreement.
d. All administrative expenses of arbitration proceedings commenced under this Agreement shall be
divided equally between you and Company, except that: (a) if the claim or dispute that is the subject of the
arbitration proceedings is less than ten thousand dollars (US$10,000), you will be responsible for no more
than one hundred twenty-five dollars (US$125) in administrative expenses; (b) if the claim or dispute that
is the subject of the arbitration proceedings is more than ten thousand dollars (US$10,000) but less than
seventy-five thousand dollars (US$75,000), you will be responsible for no more than three hundred seventy-
five dollars (US$375) in administrative expenses; and (c) if the claim or dispute that is the subject of the
arbitration proceedings is more than seventy-five thousand dollars (US$75,000), then you will be responsible
for administrative expenses in accordance with the Commercial Fee Schedule provided by the AAA. You
acknowledge and agree that each party shall pay the fees and costs of its own counsel, experts
and witnesses.
UV lamp replaced on:
Purchased at:
UV lamp replaced on:
Purchased at:
4. CHOICE OF LAW.
This Agreement shall be governed by the United States Federal Arbitration Act and the laws of the
State of California.
5. SEvERABILITY.
UV lamp replaced on:
Purchased at:
If any provision of this Agreement is declared or found to be unlawful, unenforceable or void, such provision
will be ineffective only to the extent that it is found unlawful, unenforceable or void, and the remainder of the
provision and all other provisions shall remain fully enforceable.
101M
Download from Www.Somanuals.com. All Manuals Search And Download.
16
17
noTes
noTes
101M
Download from Www.Somanuals.com. All Manuals Search And Download.
|