Invacare Scale JLS5 User Manual

JasmineScale JLS5  
Assembly, Installation and Operating Instructions  
SAVE THESE INSTRUCTIONS  
NOTE: Check all parts for shipping damage. In case of shipping damage, DO NOT use. Contact carrier/dealer for  
further instruction.  
To ensure the safe installation, operation and use of the Jasmine Scale, these instructions MUST be followed:  
WARNING  
DO NOT use this equipment without first reading and understanding these instructions. If you are  
unable to understand the Warnings, Cautions, and Instructions, contact distributor before  
attempting to use this equipment, otherwise, injury or damage may result.  
The weight capacity is limited to the lowest rated capacity of any one of the components in use (i.e.,  
Patient Lift, Sling or Scale). The patient’s weight MUST NOT exceed the lowest rated capacity of any  
component.  
After ANY adjustments, repair or service and before use, make sure that all attaching component  
parts are secure.  
ACCESSORIES WARNING  
Invacare products are specifically designed and manufactured for use in conjunction with Invacare  
accessories. Accessories designed by other manufacturers have not been tested by Invacare and are  
not recommended for use with Invacare products.  
Kit Description  
DESCRIPTION  
Load Cell Assembly  
Nylon Washers  
Swivel Bar Pin  
Locknut  
Mounting Screw  
Small Steel Washer  
QUANTITY  
1
2
1
1
1
1
Specifications  
Weight Range:  
Resolution:  
Display:  
Automatic Power Down:  
Size:  
Up to 500 lbs (226.7 Kg)  
+/- 0.2 lbs (0.1 Kg)  
Liquid Crystal Digital  
Two minutes  
5-3/4 L X 3-5/8 W X 4 H  
.55 lbs  
Weight:  
Power:  
Battery Life:  
Temperature Range:  
9-Volt Alkaline battery (included)  
Approximately 1500 readings  
50° To 104°F (10° To 40°C)  
Part No 1152408  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Jasmine Scale  
NOTE: For this procedure, refer to FIGURE 2.  
WARNING  
Patient and sling MUST be removed from the lift during ALL installation procedures.  
1. Position the load cell assembly of the Jasmine Scale into the boom mounting bracket (Detail ʺAʺ of  
FIGURE 2).  
2. Secure the Jasmine Scale to the boom mounting bracket with a bolt, washers, bushings, nylon  
washers, locknut and the top rubber cap. Securely tighten. Install the small rubber cap.  
NOTE: Refer to Detail ʺAʺ of FIGURE 2 for washer and small rubber cap orientation.  
NOTE: Ensure the shaft of the bolt passes through both sides of the boom mounting bracket.  
3. Insert swivel bar pin with an oring and a washer through the swivel bar (Detail ʺBʺ of FIGURE 2).  
4. Align the mounting holes in the swivel bar pin with the mounting holes in the load cell assembly  
(Detail ʺBʺ of FIGURE 2).  
5. Secure swivel bar pin to the load cell assembly with a screw and locknut. Tighten securely (Detail  
ʺBʺ of FIGURE 2).  
WARNING  
After ANY adjustments, repair or service and BEFORE use, make sure all attaching hardware is  
tightened securely - otherwise injury or damage may occur.  
6. Weigh the patient. Refer to Operating the Scale and Weighing the Patient in the Jasmine Patient Lift  
Owners Manual, Invacare P/N 1150704.  
DETAIL “A”  
DETAIL “B”  
Top Rubber  
Cap  
Jasmine  
Scale  
Boom  
Mounting  
Bracket  
Locknut  
Screw  
Bushing  
Washer  
Bolt  
Washer  
Bushing  
Locknut  
Swivel Bar  
Small  
Rubber  
Cap  
Nylon  
Washers  
O-Ring  
Jasmine  
Scale  
Washer  
Load Cell  
Assembly  
Swivel Bar Pin  
FIGURE 2 Installing the Jasmine Scale  
Part No 1152408  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating the Scale  
Keypad Functions  
INDICATOR  
DISPLAYED  
INDICATOR  
LOCATION  
KEY  
DEFINITION  
ON  
OFF  
OFF  
Center of Display Window  
Pressing this key will apply power to the  
scale and turn the unit on. When the scale  
is already on, pressing the button will turn  
the unit off.  
ZERO  
UNITS  
ZERO  
lb or kg  
LOCK  
Lower Left Corner of the  
Display Window  
Pressing this key when the scale is on will  
reset the weight shown in the display  
window to zero.  
Upper Right Corner of the  
Display Window  
The function of this key is to change the  
unit of measurement from pounds (lb) to  
kilograms (kg).  
LOCK  
UNLOCK  
Lower Right Corner of the Display  
Window  
This key is used to LOCK or UNLOCK a  
weight value in the display window.  
NOTE: Weight displayed is a STORED  
weight and not the current weight when  
the key is used in the lock position.  
N/A  
LO BAT  
Center of Display Window  
Indicator is shown in the display window  
to notify when battery is low.  
Display  
Window  
Operation  
Keys  
Jasmine Scale  
JLS5  
CAPACITY 500 LB, 227 KG  
FIGURE 3 Operating the Scale - Keypad Functions  
Weighing the Patient  
WARNING  
The weight capacity is limited to the lowest rated capacity of any one of the components in use  
(e.g. Patient Lift, Sling or Scale). The patient's weight MUST NOT exceed the lowest rated  
capacity of any component.  
1. Attach sling straps to the swivel bar. For proper attachment instructions refer to Attaching a Sling  
to the Swivel Bar in the Jasmine Patient Lift Owners Manual, Invacare P/N 1150704.  
NOTE: For improved accuracy on the patient lift, attach all sling straps to the center hooks on both sides of the  
swivel bar. However, patient comfort may require a different configuration of sling straps.  
2. Press the ON/OFF key.  
4
Part No 1152408  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
DO NOT operate key strokes with pointed objects (e.g. pencils, pens, fingernails, etc.) Otherwise  
damage to the key pad will result.  
NOTE: The display will indicate the last weight that was measured. The word ʺLOCKʺ will be seen in the display  
box.  
NOTE: The ZERO key is pressed in order to avoid capturing the weight of the sling and the hardware. If the  
ZERO key is not pressed the weight of the sling and the weight of the hardware will be included in the weight  
displayed. NOT ZEROING OUT WILL GIVE A FALSE READING OF THE USERʹS TRUE WEIGHT.  
3. Press the ZERO key. When the ZERO key is pushed the following will happen:  
A. The scale will reset to zero and the word ʺZEROʺ will appear in the display.  
B. The lock function will then be turned off and the word ʺLOCKʺ will disappear from the display.  
NOTE: The scale is now active and continually updating the weight display.  
4. Place the patient in the sling. For patient placement instructions refer to Operation in the Jasmine  
Patient Lift Owners Manual, Invacare P/N 1150704.  
5. Activate the lift mechanism to raise the patient until they are completely supported by the lift. For  
patient lifting instructions, refer to Lifting the Patient in the Jasmine Patient Lift Owners Manual,  
Invacare P/N 1150704.  
6. Note the weight display.  
7. When the weight display becomes stable press the LOCK button to lock the weight display. This will  
be indicated by the word ʺLOCKʺ appearing in the display window.  
NOTE: Should it be necessary to unlock the weight while the patient is still supported by the lift, the UNLOCK  
button may be pressed. The weight will unlock and the word ʺLOCKʺ will disappear from the display window.  
The weight value will then be updated. Once the weight becomes stable the weight can be locked again by pressing  
the LOCK button.  
NOTE: Stable being defined as the weight fluctuating ± two tenths of a pound. For example, a patient weighing  
one hundred lbs the scale will fluctuate between 99.8 and 100.2 until the LOCK key is pressed. Fluctuation of the  
weight displayed is normal as noted above. Press the LOCK button to lock the weight.  
NOTE: The UNITS button can be pressed to toggle between units of pounds and kilograms. This is indicated by  
lb or kg appearing in the display window.  
8. The lift may now be lowered and the sling removed from the patient.  
NOTE: The patientʹs weight will continue to be seen in the display window. The display will turn off  
automatically after a two minute period of nonuse [no changes in weight exceeding five pounds (2 kilograms)].  
You can NOT adjust the time delay for automatic shut off. After the display has turned off, the weight may be  
recalled by pressing the ON/OFF button. The unit can be turned off by pressing the ON/OFF button a second  
time.  
Part No 1152408  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacing the Battery  
NOTE: For this procedure, refer to FIGURE 4.  
NOTE: The scale is powered by a 9volt alkaline battery that should provide approximately 1500 readings before  
needing replacement.  
When battery replacement is needed, LO BAT will appear on the display. Perform the following:  
1. Slide the battery door open in the direction of the arrow.  
2. Remove existing battery.  
3. Install the NEW battery.  
4. Reinstall the battery door.  
Assembled  
Scale  
9V Battery  
Battery  
Door  
Arrow  
FIGURE 4 Replacing the Battery  
Calibrate the Jasmine Scale  
NOTE: For this procedure, refer to FIGURE 5 on page 7.  
NOTE: The Jasmine Scale will be precalibrated at the factory with the load cell. Should it be necessary to recalibrate  
the scale, follow the instructions outlined below.  
1. The patient and the sling MUST be removed from the scale to properly calibrate the Jasmine Scale. Refer  
to Operation in the Jasmine Patient Lift Owners Manual, Invacare P/N 1150704, for further instructions.  
2. For sling detachment instructions, refer to Lifting the Patient in the Jasmine Patient Lift Owners Manual,  
Invacare P/N 1150704.  
3. Turn the scale display power on by pressing the ON/OFF key.  
4. Rotate the Swivel Bar until the back of the scale display is visible.  
5. Insert the tip of a paper clip or similar tool into the small hole on the back of the scale display and press  
the CAL button.  
NOTE: Once the CAL button is pressed, “CAL1” will be seen in the display window.  
6. Press the UNITS key. The display reads CAL2.  
7. Press the LOCK/UNLOCK key. The display reads UNLD.  
8. Press the ZERO key. The display reads LOAD.  
9. Hang 200 pounds of calibrated weight from the scale and press the ZERO key.  
10. Press the ZERO key. The display reads DONE.  
6
Part No 1152408  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
11. Remove the weight. Press the LOCK/UNLOCK key.  
NOTE: The scale is now in test mode.  
12. Press the ZERO key. The display reads 0.00 lb.  
NOTE: The scale will now be in normal operation.  
BACK VIEW OF SCALE DISPLAY  
CAL button  
FRONT VIEW OF SCALE DISPLAY  
Display Window  
MODEL JLS5  
CAPACITY 500 lb, 227 kg  
Troubleshooting  
SYMPTOM  
PROBABLE CAUSE  
SOLUTION  
Unit does NOT work properly.  
Battery failure.  
Check battery. Replace if necessary.  
Contact Invacare.  
Battery has been replaced and unit still does  
NOT work properly.  
Display Codes  
CAL  
CALIBRATION REQUIRED Indicates improper stored calibration data, calibration is necessary.  
OCAP  
OVER CAPACITY Indicates a weight exceeding the capacity has been loaded on the scale.  
Part No 1152408  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LIMITED WARRANTY  
PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW  
APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.  
This warranty is extended only to the original purchaser/user of our products.  
This warranty gives you specific legal rights and you may also have other legal rights which vary from state to  
state.  
Invacare warrants the products manufactured (excluding the 9V battery) to be free from defects in materials  
and workmanship for a period of two years from the date of purchase. If within such warranty period any such  
product shall be proven to be defective, such product shall be repaired or replaced, at Invacare’s option. This  
warranty does not include any labor or shipping charges incurred in replacement part installation or repair of  
any such product. Invacare’s sole obligation and your exclusive remedy under this warranty shall be limited to  
such repair and/or replacement.  
For warranty service, please contact the dealer from whom you purchased your Invacare product. In the event  
you do not receive satisfactory warranty service, please write directly to Invacare at the address on the back  
cover, provide dealer’s name, address, date of purchase, indicate nature of the defect.  
Invacare Corporation will issue a serialized return authorization. The defective unit or parts MUST be  
returned for warranty inspection using the serial number, when applicable as identification within 30 days of  
return authorization date. DO NOT return products to our factory without our prior consent. C.O.D.  
shipments will be refused; please prepay shipping charges.  
LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL  
NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED, PRODUCTS  
SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE,  
PRODUCTS MODIFIED WITHOUT INVACARE’S EXPRESS WRITTEN CONSENT (INCLUDING, BUT  
NOT LIMITED TO, MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR  
ATTACHMENTS; PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT  
WITHOUT THE SPECIFIC CONSENT OF INVACARE, OR TO A PRODUCT DAMAGED BY  
CIRCUMSTANCES BEYOND INVACARE’S CONTROL, AND SUCH EVALUATION WILL BE SOLELY  
DETERMINED BY INVACARE. THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM  
NORMAL WEAR OR FAILURE TO ADHERE TO THE INSTRUCTIONS IN THIS MANUAL.  
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES.  
IMPLIED WARRANTIES, IF ANY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE  
EXPRESSED WARRANTY PROVIDED HEREIN AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED  
WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT  
PURSUANT TO THE TERMS CONTAINED HEREIN. INVACARE SHALL NOT BE LIABLE FOR ANY  
CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER.  
SOME STATES DO NOT ALLOW EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL  
DAMAGE, OR LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE  
EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU.  
THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE OR PROVINCIAL LAWS AND  
REQUIREMENTS.  
Invacare Corporation  
USA  
Canada  
All rights reserved. Trademarks are identified  
by ™ and ®. All trademarks are owned by or  
licensed to Invacare Corporation unless  
otherwise noted.  
One Invacare Way  
Elyria, Ohio USA  
44036-2125  
570 Matheson Blvd. E Unit 8  
Mississauga Ontario  
L4Z 4G4 Canada  
800-668-5324  
800-333-6900  
©2008 Invacare Corporation  
Part No 1152408  
Rev B - 10/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

JAMO Speaker IW 626 LCR User Manual
John Lewis Washer JLWM1201 User Manual
JVC Personal Computer LYT1116 001A User Manual
Kenmore Dishwasher 6651628 User Manual
Kensington Switch SE 20 User Manual
KitchenAid Refrigerator W10608689A User Manual
KitchenAid Ventilation Hood KICU265BAL0 User Manual
Klipsch Headphones $299 User Manual
Kodak Digital Camera Auto Focus Camera User Manual
K Tec Blender HP3A User Manual