Invacare Oxygen Equipment 1150693 User Manual

Owner’s Manual  
Invacare®Twilight™Full  
Face Mask  
LATEX  
FREE  
This owner’s manual is to be used in conjunction with the  
supplemental sheet provided, part no. 1150693.  
USER: Before using this product, read the owner’s manual  
and supplemental sheet and save for future reference.  
DEALER: The owner’s manual and supplemental sheet MUST  
be given to the end user.  
For more information regarding  
Invacare products, parts, and services,  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TABLE OF CONTENTS  
TABLE OF CONTENTS  
REGISTER YOUR PRODUCT  
The benefits of registering include:  
1. Safeguarding your investment.  
2. Ensuring long-term maintenance and servicing of your product.  
3. Receiving updates with product information, maintenance tips and industry  
news.  
Register ONLINE at warranty.invacare.com  
Please have your model number and purchase date available to complete your  
registration.  
Any registration information you submit will only be used by Invacare  
Corporation and protected as required by applicable laws and regulations.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 1—GENERAL GUIDELINES  
SECTION 1—GENERAL GUIDELINES  
WARNING  
SECTION 1 - GENERAL GUIDELINES contains important information for  
the safe operation and use of this product.  
If oxygen is used in conjunction with a PAP machine and the full face mask,  
the oxygen flow MUST be turned Off when the PAP machine is not  
operating. If the oxygen flow is left On, oxygen may accumulate within the  
tubing, machine enclosure, or the mask surroundings. Accumulated  
oxygen in the tubing, machine enclosure, or the mask surroundings may  
increase the risk of fire.  
CAUTION  
“Caution: Federal law restricts this device to sale or rental by or on order of a  
physician, or any other practitioner licensed by the law of the state in which  
he/she practices to use or order the use of this device.”  
At low CPAP pressures the flow through the exhalation port may be inadequate  
to clear all exhaled gas from the tubing. Some rebreathing may occur.  
This Twilight Full Face Mask should be used only with PAP systems  
recommended by your physician or respiratory therapist. A mask should not be  
used unless the PAP system is turned On and operating properly.  
This mask is a full face mask, which covers both the nose and the mouth.  
NEVER block the vent hole or holes associated with the mask.  
DO NOT use an electrically conductive breathing tube.  
PAP systems are intended to be used with special masks which have vent holes  
to allow continuous flow of air out of the mask. When the PAP machine is  
turned On and functioning properly, new air from the PAP machine flushes the  
exhaled air out through the mask exhalation vent holes. However, when the  
PAP machine is not operating, not enough fresh air is provided through the  
mask, and exhaled air may be rebreathed. Rebreathing of exhaled air for longer  
than several minutes can in some circumstances lead to suffocation. This  
warning applies to most models of PAP systems.  
The mask may not be suitable for those with risk of gastric regurgitation or  
similar conditions.  
For patients who are unable to remove the mask, it MUST be used under  
qualified supervision.  
At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen  
concentration will vary, depending on the pressure settings, patient breathing  
pattern, mask selection, and the leak rate. This warning applies to most types of  
CPAP systems.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 2—USING THE MASK ASSEMBLY  
SECTION 2—USING THE MASK ASSEMBLY  
Assembling the Cushion  
NOTE: For this procedure, refer to SECTION A in supplemental sheet provided.  
1. Remove the cushion from the plastic bag and install onto the mask  
frame.  
2. Align the keying features at the bottom and sides of the cushion to the  
mating keying features on the mask frame.  
3. Gently push the cushion ribbing down into the mounting channel on  
the mask frame.  
NOTE: The cushion is completely seated in the mounting channel when the  
cushion and the mask frame meet forming a gapless seam around the outside edge.  
Inspecting the Mask  
NOTE: For this procedure, refer to SECTION B in supplemental sheet provided.  
NOTE: Wash the headgear before using it for the first time, as dye may run. Refer  
NOTE: Invacare recommends washing your face before fitting the mask. This will  
remove excess facial oil and extend the life of the mask.  
Check the following:  
Check that the valve flap is clean and dry.  
Inspect the valve flap for any damage or wear.  
Ensure that the valve flap is mounted to the mask swivel.  
Ensure that the mask and tubing swivels rotate properly.  
Ensure the port is plugged.  
Ensure the exhalation vent holes are clear.  
Check Valve Function  
WARNING  
DO NOT use the mask if the valve flap is damaged or missing.  
NOTE: If the valve flap is damaged, distorted, or torn, it should be replaced with  
a new part.  
NOTE: For this procedure, refer to SECTION C in supplemental sheet provided.  
1. Connect a standard 22mm bore, 6-foot tube from your flow generator  
to the hose swivel by pressing the tube end over the swivel.  
2. Turn On the flow generator.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
SECTION 2—FITTING THE MASK  
3. Check that the valve functions properly by sealing off the cushion  
facial opening. The valve flap should cover and seal the large opening  
in the mask swivel.  
4. Turn the flow generator Off. The flap should return to a straight  
position and not be blocking the large opening in the mask swivel.  
WARNING  
DO NOT place the mask on your face unless the PAP machine is  
turned On. Otherwise, injury may occur.  
Fitting the Mask  
NOTE: For this procedure, refer to SECTION D in the supplemental sheet.  
1. Before fitting the mask, unfasten one or both of the headgear clips  
from the mask frame (D-1).  
2. Place the mask on the face with the headgear straps behind the head  
(D-2).  
3. Fit the mask loosely over the nose and mouth with minimal pressure.  
4. Reattach both headgear clips to the mask frame (D-2).  
5. Adjust the mask as follows:  
A. Lift the forehead lever to the unlocked position (D-3).  
B. Slide the forehead support up or down until it contacts the  
forehead and the upper portion of the cushion lightly touches the  
bridge of the nose (D-3).  
C. Lower the forehead lever to lock the forehead support in the  
desired position (D-4).  
WARNING  
DO NOT pull the straps too tight. This can cause skin irritation and  
may deform the cushion causing a leak. If the mask and headgear are  
adjusted correctly and a problem persists, contact your health care  
professional.  
6. Adjust the strap length as needed using the hook and loop fasteners  
(D-5 and D-6).  
NOTE: If a leak occurs, adjust the forehead support. If this does not work, tighten  
or loosen the headgear straps by readjusting the hook-and-loop fasteners.  
NOTE: Proper mask fit should allow full contact of the cushion without excessive  
pressure on the face.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 2—REMOVING THE MASK AND HEADGEAR  
Removing the Mask and Headgear  
NOTE: For this procedure, refer to SECTION D in the supplemental sheet  
provided.  
1. Place your thumb and forefinger around one of the headgear clips  
(D-1).  
2. Gently pull the headgear clip away from your face.  
NOTE: It is not necessary to remove the headgear straps from the clips or the  
forehead support when removing the mask.  
3. Pull the mask forward and lift it upwards and over the head.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 3—CLEANING THE MASK  
SECTION 3—CLEANING THE MASK  
Disassembling the Mask for Cleaning  
NOTE: For this procedure, refer to SECTION B, SECTION C, SECTION E, and  
SECTION F on supplemental sheet.  
1. Detach the headgear from the forehead support by unfastening the  
hook-and-loop fastener tabs from the headgear and sliding the straps  
out of the slot in the forehead support (SECTION C).  
NOTE: It is not necessary to detach the clips from the headgear for daily washing  
unless desired.  
NOTE: It is not necessary to completely disassemble the mask for daily cleaning  
in the home. The mask can be cleaned and rinsed while still assembled. It is  
recommended to disassemble the mask for cleaning at least once per week.  
2. Lift the forehead lever to the unlocked position (E-2).  
3. Rotate the forehead support and remove from mask frame (E-3).  
4. Rotate the forehead lever outward and remove from the mask frame  
(E-4).  
NOTE: It is not necessary to remove the forehead support after every use. It can  
be cleaned and rinsed while it is mounted to the mask frame.  
5. Remove the cushion from the mask frame by slowly pulling the  
cushion off (SECTION B).  
6. Remove the retaining ring on the outside of the mask swivel (F-1).  
7. Remove the mask swivel by rotating it back through the opening in  
the mask frame (F-2).  
8. Remove the hose swivel by pulling it off the mask swivel (F-3).  
9. Gently remove the valve flap by pulling it out of the mask swivel (F-3).  
10. Uncover the port by grabbing the tab on the port plug and gently  
pulling up (F-4).  
11. Remove the port plug from the mask frame by holding it near the  
attachment point and gently pulling it straight out (F-4).  
NOTE: Placing the components in the wash solution first can ease in the removal  
of the port plug from the mask frame.  
NOTE: It is not necessary to remove the valve flap and the port plug completely  
after every use. They can be cleaned and rinsed while attached to the mask frame.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SECTION 3—CLEANING THE MASK AND HEADGEAR  
Cleaning the Mask and Headgear  
CAUTION  
ALWAYS be sure to remove any foreign material (dirt, lint, etc.)  
from the exhalation vents.  
DO NOT use bleach, chlorine, aromatic-based cleaning solutions,  
scented oils, or moisturizing or antibacterial soaps to clean the mask  
components. These solutions may cause hardening and reduce the life  
of the product.  
Alcohol may be used to clean the silicone cushion ONLY. DO NOT  
use alcohol to clean the mask frame, headgear or air tubing.  
WARNING  
DO NOT expose any part of the mask system or tubing to direct  
sunlight as it may cause mask deterioration.  
ALWAYS rinse mask thoroughly after cleaning. Insufficient rinsing of  
cleaning agents can result in severe skin rash, irritation and skin  
breakdown. Discontinue using the mask if there is an allergic reaction  
to any part of the mask, and contact your healthcare professional.  
Washing the mask in an automatic dishwasher is not recommended.  
Doing so may damage or affect the life of the valve flap or the  
product. Also, the automatic dishwasher cleaning and rinsing agents  
may leave a residue on the mask, which may cause skin irritation.  
For multi-patient use/reuse, clinicians should refer to the Mask  
Disinfection and Sterilization Guide (p/n 1130216).  
The headgear cannot be disinfected or sterilized. Refer to instruc-  
tions below for washing the headgear.  
NOTE: Wash the entire mask system (except the headgear) after each use.  
NOTE: Wash the headgear at least once per week.  
NOTE: ALWAYS hand wash the headgear to increase the life of the product.  
2. Hand wash the headgear in warm or cool water using a mild  
detergent.  
3. Rinse the headgear thoroughly and allow to air dry.  
4. Hand wash the mask components using a mild detergent, such as  
hand dishwashing detergent, in warm water.  
5. Rinse the mask components thoroughly and allow them to air dry.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SECTION 3—ASSEMBLING THE MASK  
Assembling the Mask  
CAUTION  
Replace the mask or mask component if damaged or deteriorated.  
Dispose of any damaged or broken parts in an environmentally  
friendly manner or as normal household waste.  
WARNING  
DO NOT use the mask if the valve flap is damaged or missing.  
NOTE: For this procedure, refer to SECTION A, SECTION C, SECTION E, and  
SECTION F on supplemental sheet provided.  
1. Inspect all components for damage or wear.  
2. Replace the port plug onto the mask frame by pushing the barb on the  
port plug into the hole in the mask frame while gently pulling the barb  
through from the other side until the barb snaps into place (F-4).  
3. Push the port plug down over the port on the mask frame to seal the  
port (F-4).  
4. Check that the valve flap is clean and dry (F-3).  
5. Slide the valve flap into the slot in the mask swivel. Gently pull it  
through from the inside while pushing it in from the outside until it  
snaps into place (F-3).  
6. Snap the hose swivel onto the mask swivel (F-3).  
7. Insert the mask swivel through the opening in the mask frame from  
the inside (F-2).  
8. Lock the mask swivel into place on the outside of the mask frame by  
slipping the retaining ring over the mask swivel (F-2).  
9. Push the retaining ring into the groove on the swivel until it snaps in  
place (F-1).  
NOTE: Align the keying features at the bottom and sides of the cushion to  
the mating keying features on the mask frame (SECTION A).  
10. Gently push the cushion ribbing down into the mounting channel on  
the mask frame.  
NOTE: The cushion is completely seated in the mounting channel when the  
cushion and the mask frame meet forming a gapless seam around the outside edge.  
11. If necessary, reattach the forehead support as follows:  
A. Slide the forehead lever onto the mask frame (E-4).  
B. Position the forehead lever into the unlocked position (E-3).  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
WARRANTY  
C. Slide the forehead support into the mask frame and place at  
desired position (E-2).  
D. Lower the forehead lever to lock the forehead support in the  
desired position (E-1).  
12. Attach the headgear to the mask by sliding the upper headgear straps  
through the loophole of the forehead support. The tan side of the  
headgear goes against the head and the Invacare label will be on the  
outside of the upper strap (SECTION C).  
13. Loosely secure each side of the upper headgear strap by folding them  
back and using the hook-and-loop fastening strips to secure the ends  
of the straps to the upper headgear strap (SECTION C).  
14. Slide the lower headgear strap through the loopholes of the headgear  
clips (SECTION C).  
15. Loosely secure each side of the lower headgear strap by folding them  
back and using the hook-and-loop fastening strips to secure the ends  
of the straps to the lower headgear strap (SECTION C).  
NOTE: Prior to use, inspect the mask and check the valve function. Refer to  
WARRANTY  
PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY  
WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER  
JULY 4, 1975.  
This warranty is extended only to the original purchaser/user of our products.  
This warranty gives you specific legal rights and you may also have other legal rights  
which vary from state to state.  
Invacare warrants the Twilight Full Face Mask to be free from defects in materials and  
workmanship for a period of 90 days from date of purchase. If within such warranty  
period any such product shall be proven to be defective, such product shall be repaired or  
replaced, at Invacare's option. This warranty does not include any labor or shipping  
charges incurred in replacement part installation or repair of any such product.  
Invacare's sole obligation and your exclusive remedy under this warranty shall be limited  
to such repair and/or replacement.  
For warranty service, please contact the dealer from whom you purchased your Invacare  
product. In the event you do not receive satisfactory warranty service, please write  
directly to Invacare at the address on the back cover, provide dealer's name, address,  
date of purchase, indicate nature of the defect and, if the product is serialized, indicate  
the serial number. Do not return products to our factory without our prior consent.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT  
APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN  
REMOVED OR DEFACED, PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT,  
IMPROPER OPERATION, MAINTENANCE OR STORAGE, COMMERCIAL OR  
INSTITUTIONAL USE, PRODUCTS MODIFIED WITHOUT INVACARE'S EXPRESS  
WRITTEN CONSENT (INCLUDING, BUT NOT LIMITED TO,  
MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR  
ATTACHMENTS; PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY  
COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE, OR TO A  
PRODUCT DAMAGED BY CIRCUMSTANCES BEYOND INVACARE'S CONTROL,  
AND SUCH EVALUATION WILL BE SOLELY DETERMINED BY INVACARE. THE  
WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR  
OR FAILURE TO ADHERE TO THE FOLLOWING INSTRUCTIONS.  
THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY  
OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESS OR IMPLIED,  
INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS  
FOR A PARTICULAR PURPOSE, AND THE SOLE REMEDY FOR VIOLATIONS OF  
ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR OR  
REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS  
CONTAINED HEREIN. THE APPLICATION OF ANY IMPLIED WARRANTY  
WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS  
WARRANTY PROVIDED HEREIN. THE MANUFACTURER SHALL NOT BE LIABLE  
FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER.  
THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL  
LAWS AND REQUIREMENTS.  
Invacare Corporation  
USA  
Manufactured by:  
Invacare Corp.  
One Invacare Way  
Elyria, Ohio USA  
44036-2125  
2101 E. Lake Mary Blvd.  
Sanford, FL 32773  
800-832-4707  
800-333-6900  
Technical Services  
800-832-4707  
All rights reserved. Trademarks are  
identified by ™ and ®.  
All trademarks are owned by or  
licensed to Invacare Corporation  
unless otherwise noted.  
R
© 2007 Invacare Corporation  
Part No 1130237  
Rev A - 9/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Indesit Water System SIXL 145 User Manual
Infinity Speaker System CC225 User Manual
Ingersoll Rand Impact Driver 1215Ti and 1225Ti User Manual
Intel Computer Hardware SASMF8I User Manual
Jet Tools Saw JPS 10 User Manual
JVC Scanner KD S731R User Manual
JVC Speaker System SX XDC33 User Manual
KitchenAid Cooktop W10440551A User Manual
KitchenAid Microwave Oven KCMS1555 User Manual
Kodak Digital Camera C1450 User Manual