1 GENERAL  
1 General  
1.1 Symbols and Signal Words  
Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. See the  
information below for definitions of the signal words.  
DANGER  
ƽ
Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.  
WARNING  
ƽ
Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  
CAUTION  
ƽ
Caution indicates a potentially hazardous situation which, if not avoided, may result in property damage or minor injury or  
both.  
IMPORTANT  
!
Indicates a hazardous situation that could result in damage to property if it is not avoided.  
Gives useful tips, recommendations and information for efficient, trouble-free use.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1 GENERAL  
1.2 Limited Warranty  
PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW  
APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.  
This warranty is extended only to the original purchaser/user of our products.  
This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state.  
Invacare Continuing Care, Inc. (ICC1) warrants its bathing/whirlpool products to be free from defects in materials and workmanship for a period of three  
years from the date of purchase. The door seal is warranted for the life of the tub. Warranty obligation is limited to parts replacement only. Warranty  
replacement parts are only covered for the duration of the warranty period. All purchased replacement parts will carry a 30-day warranty from the date of  
shipment. If within such warranty period any such product shall be proven to be defective, such product shall be repaired or replaced, at ICCI's option. This  
warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product. ICCI's sole obligation and  
your exclusive remedy under this warranty shall be limited to such repair and/or replacement.  
For warranty service, please contact the dealer from whom you purchased your ICCI product. In the event you do not receive satisfactory warranty service,  
please write directly to ICCI at the address below. Provide dealer's name, address, model number, date of purchase, indicate nature of the defect and, if the  
product is serialized, indicate the serial number.  
ICCI will issue a return authorization. The defective unit or parts must be returned for warranty inspection using the serial number, when applicable, as  
identification within thirty days of return authorization date. DO NOT return products to our factory without our prior consent. C.O.D. shipments will be  
refused; please prepay shipping charges.  
LIMITATIONS AND EXCLUSIONS: THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO  
ADHERE TO THE ENCLOSED INSTRUCTIONS. LABOR; EXPENDABLE ITEMS, I.E. SHOWER HOSES, VALVES, “O” RINGS, SEALS; PARTS BROKEN  
DUE TO ABUSE OR IMPROPER USE; ITEMS THAT BECOME INOPERABLE DUE TO LACK OF MAINTENANCE, OR NON COMPATIBLE  
CHEMICALS; STAINS DUE TO HARD WATER, IODINE SOLUTIONS, OR OTHER UNAPPROVED CHEMICALS; “SPIDER” CRACKS OR  
“CRACKING” DUE TO MISHANDLING OR ABUSE. IN ADDITION, THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED  
PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED; PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER  
OPERATION, MAINTENANCE OR STORAGE; OR PRODUCTS MODIFIED WITHOUT ICCI'S EXPRESS WRITTEN CONSENT INCLUDING, BUT  
NOT LIMITED TO: MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS: PRODUCTS DAMAGED BY  
REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF ICCI; PRODUCTS DAMAGED BY  
CIRCUMSTANCES BEYOND ICCI'S CONTROL; PRODUCTS REPAIRED BY ANYONE OTHER THAN AN ICCI DEALER, SUCH EVALUATION  
SHALL BE SOLELY DETERMINED BY ICCI.  
THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESS OR  
IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE SOLE  
REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE  
PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN. THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT  
EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN. THE MANUFACTURER SHALL NOT BE LIABLE FOR  
ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER.  
THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2 SAFETY  
2 Safety  
The Safety section contains important information for the safe operation and use of this product.  
2.1 General Guidelines  
WARNING  
ƽ
DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and  
any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional  
equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical  
personnel before attempting to use this equipment - otherwise, injury or damage may occur.  
ACCESSORIES WARNINGS  
Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by  
other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products.  
ƽ
!
NOTICE  
THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE.  
2.2 Important Safety Information  
DANGERS - ELECTRICAL SHOCK HAZARD  
Grounding is required.  
The installation and maintenance of the tub MUST be done by a qualified technician, certified electrician or plumber.  
Disconnect electrical supply or turn off circuit breaker before installing or performing any maintenance on the tub.  
The unit MUST be connected only to a supply circuit that is protected by a ground fault circuit-interrupter (GFCI).  
Be certain ALL electrical work is performed by a qualified electrician and is in compliance with local electrical codes.  
ALL electrical connections are to be water resistant.  
ƽ
DANGER - RISK OF SCALDING  
The hot water supply to the tub MUST not exceed 110°F (43° C) to protect the user from scalding.  
ƽ
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2 SAFETY  
WARNING - PLUMBING  
Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes.  
ƽ
ƽ
WARNING - FLOOR LOAD CAPACITY  
The installation area MUST be able to support the 66 pounds per square inch (45 n/cm²) load capacity of the tub. Otherwise, injury or  
damage might occur.  
WARNINGS - SAFE USE  
ƽ
Use this unit only for its intended use as described in this manual.  
If any part of the system is not functioning properly, DO NOT use the tub.  
NEVER drop or insert any object into any opening.  
DO NOT operate the tub without the jet assemblies installed.  
The tub MUST be cleaned and disinfected after each use. Refer to Cleaning and Disinfecting on page 23.  
Keep hair and body away from the jet assemblies when pump is running.  
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of  
98.6° F. The symptoms of hyperthermia include an increase of the internal temperature of the body, dizziness, lethargy, drowsiness, and  
fainting.  
The tub is specifically designed to be used with a bath lift. ICCI recommends use of the Traverse Lift Model 1900 ONLY. Bath lifts  
designed by other manufacturers are NOT to be used with the tub. Use the Traverse Lift Model 1900 to maintain resident safety and  
product utility. Refer to the lift owner’s manual for complete lift operating and safety instructions.  
To reduce the risk of injury, DO NOT permit children or infirm persons to use this tub UNLESS THEY ARE SUPERVISED AT ALL  
TIMES.  
Recommended length of time spent in a bath is 5 to 10 minutes. However, if you or the person you are caring for becomes nauseated or  
dizzy or the person develops a headache, get out of the tub at once and safely bring the body temperature back to normal (98.6°F).  
Seek medical attention if symptoms or sickness persist. Check with the physician BEFORE using the tub again.  
Anyone under a doctor’s supervision, pregnant, or with poor health should check with a physician BEFORE using this tub.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 OVERVIEW  
Fill Spout  
Shower/Massage Wand  
Overflow  
Flow Control  
Valve  
Adjustment for angle of  
wand in cradle  
Shower Spray  
Adjustment  
Whirlpool Jet  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 OVERVIEW  
3.2 Product Labeling  
Model 3652G  
Labels located inside the Cabinet Door  
Models 3602GXL  
Cabinet Door  
Label located on interior hardware  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3 OVERVIEW  
3.3 Typical Product Parameters  
3602GXL  
3652G  
Weight  
Tub (shipping weight)  
Tub (empty)  
Tub (filled without user)  
Floor Load Capacity  
324 pounds (147 kg)  
274 pounds (124 kg)  
380 pounds (172 kg)  
66 PSI (45 n/cm²)  
313 pounds (142 kg)  
263 pounds (119 kg)  
350 pounds (158 kg)  
66 PSI (45 n/cm²)  
Minimum Space Requirements:  
Exterior Length/Interior Length:  
Exterior Width/Interior (Seat) Width:  
Overall Height/Rim Height:  
Side Access Door Swing:  
Volume Capacity (without user):  
Lift Base Clearance:  
7 feet x 6 feet  
72 inches/56 inches  
34 inches/23 inches  
42.75 inches/35.5 inches  
40 inches  
67 inches/56 inches  
32 inches/26 inches  
45 inches/35.5 inches  
38.5 inches  
64 gallons  
6 inches  
6 1/4 inches  
Whirlpool Motor (each):  
Number of Jet Outlets:  
115VAC, 60Hz, 0.7 Amps  
4
Tub Material:  
Double-wall gel coated fiberglass  
2 inch dial, 75° to 120° F (25° - 50° C)  
Moen ExactTemp®  
Thermometer:  
Anti-Scald Water Regulator:  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3 OVERVIEW  
3.4 Minimum Floor Space and Clearance Requirements  
Model 3602GXL  
Tub is shown with Model 1900 Traverse lift.  
12’  
80TO 98”  
40” MIN  
6” to 24”  
9” RECOMMENDED  
SERVICE ACCESS  
AWAY FROMWALL  
Allow for a 40”  
door swing  
9’  
12’  
12”  
36” MIN  
36”  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 OVERVIEW  
Model 3652G  
Tub is shown with Model 1900 Traverse lift.  
12’  
76.5” to 94.5”  
6” to 24”  
38.5”  
9” RECOMMENDED  
SERVICE ACCESS  
AWAY FROMWALL  
8.5’  
12’  
36” MIN  
36”  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 OVERVIEW  
3.5 Dimensions  
Model 3602GXL  
Connection  
Location  
Type  
C
9.5” (241 mm) from  
left side of tub, 5.5”  
(140 mm) up from  
floor  
3/4” Cold water stub  
(with recommended shut  
off valve)  
D
E
16.5” (419 mm) inside 2” Drain (floor drain  
of the door recommended)  
27” (686 mm) from left 115V AC, 60 Hz 15 A  
side of tub, 14” (355  
mm) up from floor  
Input  
H
7” (178 mm) from left 3/4” Hot water stub (with  
side of tub, 5.5” (140  
mm) up from floor  
recommended shut off  
valve)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 OVERVIEW  
Model 3652G  
Connection  
Location  
Type  
C
4.625” (117 mm) from 3/4” Cold water stub  
centerline, 5.5” (140  
mm) up from floor  
(with recommended shut  
off valve)  
D
E
4” (102 mm) from left 2” Drain (floor drain  
inside wall, 5” (127  
mm) from front inside  
wall of tub  
recommended)  
4.875” (124 mm) from 115V AC, 60 Hz 15 A  
centerline, 9” (229  
mm) up from floor, 4”  
(102 mm) up from  
bottom of tub  
Input  
H
4.875” (124 mm) from 3/4” Hot water stub (with  
centerline, 5.5” (140  
mm) up from floor  
recommended shut off  
valve)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 INSTALLATION  
4 Installation  
WARNINGS  
ƽ
Check all parts for shipping damage. In case of damage, DO NOT use. Contact the carrier for further instruction.  
The installation area MUST be able to support the 66 pounds per square inch (45 n/cm²) load capacity of the tub. Otherwise, injury or  
damage may occur.  
Access for servicing the tub MUST be provided. Install the tub in a location that will permit access to the service panels, plumbing and  
electrical hookups.  
CAUTIONS  
DO NOT lift the tub by the plumbing.  
DO NOT modify the tub in any way. Modifications to the system or any component may cause the system to malfunction and will void the  
warranty.  
ƽ
ICCI assumes no responsibility for code infractions or damage to components due to improper installation.  
Use extreme care during installation.  
After installation and before use ensure all parts are properly and securely installed.  
Ensure the bathroom floor is dry and free of obstructions before transporting or assembling the unit.  
4.1 Preparing the Work Area  
Access for servicing the tub MUST be provided.  
1. Determine location for the tub installation.  
Follow the recommended floor plan when installing the tub. Refer to Minimum Floor Space and Clearance Requirements on page 12.  
2. Carefully remove the tub from the carton and inspect for shipping damage. If damage is found, contact the carrier.  
3. Remove the tub from the shipping pallet by removing the screws from the leg mounting pads.  
4. Remove the four screws securing the service access panel on the back of the tub.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4 INSTALLATION  
4.2 Electrical and Plumbing Hook-up Locations on the Tub  
Model 3602GXL  
Model 3652G  
Electrical Line  
Routing Hole  
Electrical Line Routing Hole  
¾-inch Hot and  
Cold Water  
Inlets  
Hot Water Inlet  
Cold Water Inlet  
2-inch Drain PVC Pipe  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4 INSTALLATION  
4.3 Securing the Tub  
SECURING LEGS TO FLOOR  
WARNINGS  
Protective eye wear MUST be worn when drilling to  
avoid possible eye injury.  
Leg  
ƽ
Leg Mounting Pad  
DO NOT adjust height of legs more than 1 inch (25.4  
mm) for Model 3652G or 2 inches (50.8 mm) for  
model 3602GXL; leg will disassemble from leg  
mounting pad and serious injury may occur.  
Lag Bolt  
1. Set the tub in place.  
Lag Bolt  
2. Ensure the plumbing and electrical hook-ups have been installed.  
3. Mark the locations of the anchor holes, using pre-drilled holes in leg  
mounting pads as a template.  
Anchors  
LEVELING SIDE TO SIDE  
4. Move the tub away from the mounting area.  
Level  
5. Drill anchor holes in floor. Use jack-drill and carbide bit in concrete  
or a wood bit for wood floors.  
6. Reposition the tub in the mounting area, aligning the holes in the leg  
mounting pads with the holes drilled in STEP 4.  
4.4 Leveling the Tub  
1. Level the tub by adjusting the telescopic legs either up or down,  
using a wrench, to arrive at the desired height.  
LEVELING END TO END  
Level  
2. Check to make sure the tub is level by placing a level on the front  
and sides of the tub.  
3. Repeat STEPS 1 and 2 until the tub is level.  
4. Secure the legs to the floor using fasteners appropriate to the floor  
material and in keeping with local codes.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4 INSTALLATION  
4.5 Electrical Installation  
DANGERS - ELECTRICAL SHOCK HAZARD  
Grounding is required.  
The installation and maintenance of the tub MUST be done by a qualified technician, certified electrician or plumber.  
Disconnect electrical supply or turn off circuit breaker before installing or performing any maintenance on the tub.  
ƽ
The National Electric Code requires the use of a ground fault circuit interrupter on all therapeutic pools and tubs (hydro therapeutic  
tanks). Failure to follow this requirement could result in serious or fatal injury. Use a 15 AMP GFCI breaker only.  
Be certain ALL electrical work is performed by a qualified electrician and is in compliance with local electrical codes.  
ALL electrical connections MUST be water resistant.  
WARNINGS  
ƽ
The unit MUST be connected only to a supply circuit that is protected by a ground fault circuit-interrupter (GFCI). Such a GFCI should  
be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt  
power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, GFCI is defective. If the GFCI  
interrupts power to the bathtub without the test button being pushed, a ground current is flowing, indicating the possibility of an electric  
shock. DO NOT use this tub. Disconnect the tub and have the problem corrected by a qualified service representative BEFORE use.  
All electrical conduit, fittings and wire to unit are to be supplied and installed by a professional electrician in accordance with the National  
electrical code as a minimum requirement, including the supply and installation of a Ground Fault Circuit Interrupter (GFCI).  
For Canadian installation, ground fault interrupter and a 30-minute maximum timer MUST be installed in the electrical circuit. (Parts not  
supplied by ICCI). The unit must be operated through the circuit. The 30-minute timer must be located in a position where a person in  
the unit cannot reach the timer.  
Use a 15 AMP GFCI breaker only.  
Ensure a 15 AMP GFCI breaker is installed to protect the unit. Insert the plug into a pre-installed GFCI protected hospital grade receptacle.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4 INSTALLATION  
4.6 Plumbing Installation  
DANGER  
ƽ
Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes.  
WARNINGS  
ƽ
Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes.  
Some state and local plumbing codes require the installation of a “reduced pressure zone” (RPZ) assembly on both the incoming hot and  
cold supply lines to prevent back flow contamination into the potable water system. Invacare recommends you check local plumbing  
code requirements to determine if RPZs are required on your tub installation. RPZs are NOT supplied by Invacare and are to be  
provided by the customer if required.  
CAUTIONS  
ƽ
Purge water lines. Hot and cold lines MUST be purged (blown down) to clear lines of debris prior to connection. Valves and spray heads  
may become inoperable and/or damaged if lines are not properly cleared. Items damaged in this way are not covered under the warranty.  
When operating water pressure exceeds 55 PSI, pressure regulators (similar to the ¾-inch Watts U5) MUST be installed.  
1. Refer to Electrical and Plumbing Hook-up Locations on the Tub on page 17 for the location of the hot water stub and cold water stub.  
2. Measure the location of the drain on the unit.  
3. Install the drain in the floor in the appropriate location determined in STEP 2.  
4. Purge water lines. Hot and cold lines MUST be purged (blown down) prior to connection, to clear lines of debris.  
5. Install On/Off valves at wall and use unions between valves and stubs.  
6. Connect hot and cold supply lines to ¾-inch copper pipes found on back of tub in accordance with applicable building codes.  
7. Connect 2-inch drains in accordance with local plumbing codes.  
8. Attach the shower/massage wand and flow valve. Be sure to use the washers supplied.  
9. Check for leaks in supply or drain lines and check operation of tub. Refer to Operating Instructions on page 22.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4 INSTALLATION  
Check local codes regarding maximum water temperature allowed at hot water outlets for facility type.  
In House Water Service  
COLD  
HOT  
Optional Pressure Regulator  
Tub Spout  
Mixing Valve  
Shower Control Valve  
Tub Fill Valve  
Shower  
Wand  
Backflow Preventor  
(located inside tub cabinet)  
4.7 Post Installation Checklist  
Before putting the tub into service, check the following:  
Water lines have been purged of any foreign matter.  
Both hot and cold water lines are properly connected to the tub.  
Dedicated 115V 15 AMP AC power line is properly wired to the unit.  
Power line is protected by a 15 AMP GFCI.  
All water lines are checked for leaks.  
ICCI skin care and cleaning products have been ordered. To place your order, call 800-668-2337.  
ICCI representative has been called to arrange for an In-Service on the tub. To schedule, call 800-668-2337.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 OPERATING INSTRUCTIONS  
5 Operating Instructions  
5.1 Overview  
WARNINGS  
ƽ
Read and understand ALL information in this manual BEFORE use.  
Clean and disinfect the tub after EACH use to avoid resident infection and contamination of the tub.  
DO NOT clean or disinfect the tub when it is occupied. Otherwise injury may occur.  
To reduce the risk of injury, DO NOT permit children or infirm persons to use this tub UNLESS THEY ARE SUPERVISED AT ALL TIMES.  
Recommended length of time spent in a bath is 5 to 10 minutes. However, if you or the person you are caring for becomes nauseated or  
dizzy or the person develops a headache, get out of the tub at once and safely bring the body temperature back to normal (98.6°F). Seek  
medical attention if symptoms or sickness persist. Check with the physician BEFORE using the tub again.  
Anyone under a doctor’s supervision, pregnant, or with poor health should check with a physician BEFORE using this tub.  
Water Temperature Thermometer  
Whirlpool On/Off Button  
Water Temperature Control  
Fill Button  
(Push-in once to auto-fill,  
push-in and hold to add  
additional water to tub)  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 OPERATING INSTRUCTIONS  
Perform these procedures in the following order:  
1. Make sure that the tub has been cleaned, disinfected and BEFORE use. Refer to Cleaning and Disinfecting on page 23.  
2. Open the tub door.  
3. Transfer the resident to the tub.  
4. Use the shoulder and waist straps to help stabilize the resident in the tub as necessary. Refer to Shoulder and Waist Straps on page 27.  
5. Fill the tub.  
6. Bathe the resident.  
7. Drain the tub.  
8. Remove the shoulder and waist straps (if used).  
9. Open the door.  
10. Transfer the resident from the tub.  
11. Clean and disinfect the tub, including the door seal, shoulder and waist straps.  
12. Leave the door ajar when tub is not in use to avoid compressing the seal. This will prolong the life of the door seal.  
5.2 Cleaning and Disinfecting  
WARNINGS  
ƽ
ƽ
Clean and disinfect the tub after EACH use to avoid resident infection and contamination of the tub.  
DO NOT clean or disinfect the tub when it is occupied. Otherwise injury may occur.  
Read and understand ALL information on disinfecting BEFORE use.  
ALWAYS wear rubber gloves, an apron and a face shield when using disinfectant. In case of eye or skin contact, follow procedures on the  
disinfectant container.  
CAUTION  
NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners will  
make the gel-coat finish of your tub scratched and dull. NEVER use cleaners containing Iodine, Household Bleach, Bromine, Betadine® or  
Methylene Blue. The use of these types of cleaners will cause the tub to stain. Use of unapproved cleaners will dry out the rubber seals  
and gaskets and the tub will not function properly.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 OPERATING INSTRUCTIONS  
1. Use the drain plug to close the drain.  
2. Remove and disassemble all jet assemblies. Lay all pieces in the bottom of the tub.  
Rotate each jet assembly counterclockwise and pull away from the jet casing. (Detail “A”).  
Remove each impeller cap by rotating it clockwise (Detail “B”).  
Remove each impeller (Detail “C”).  
Detail “A”  
Jet Casing  
Detail “B”  
Detail “C”  
Impeller Cap  
Impeller  
Impeller  
Jet Assembly  
3. Remove the shoulder and waist straps from the mounting attachment points. Put the straps into the bottom of the tub.  
4. Clean the pieces and spray all surfaces of the tub with Dispatch® Cleaner and Disinfectant. Take a long handled brush and thoroughly clean the interior  
surfaces of the tub and the jet casings.  
5. Allow the Dispatch Cleaner and Disinfectant to sit on the surfaces for one minute.  
6. Rinse all surfaces and pieces in the footwell of the tub with water.  
7. Use a clean towel to dry all tub surfaces. Allow the shoulder and waist straps to air dry.  
WARNING  
ƽ
DO NOT put the shoulder and waist straps in the dryer, otherwise damage to the straps may occur.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 OPERATING INSTRUCTIONS  
8. Replace the impeller and impeller cap on each jet assembly by  
rotating them counterclockwise.  
WARNING  
Jet Casing  
ƽ
Cross-threading the jet assembly onto the casing may  
cause damage to the whirlpool motor. After installation,  
ensure that the jet assembly is flush against the jet casing.  
Sanijet®  
Logo  
9. Assemble each jet assembly to the jet casings.  
Position the Sanijet® logo and RED indicator at the 11 o’clock  
position.  
Insert the jet assembly into the jet casing and rotate the jet  
assembly clockwise until it locks into place.  
Jet  
Assembly  
Removing Soap Film and Hard Water Deposits  
Use a commercially available cleaner such as Invacare Heavy Duty Cleaner.  
Remove the jet assemblies. Remove the impeller caps. Thoroughly spray the  
exposed surfaces, including the jet casings. Use a long handled soft brush or  
similar product to wipe down all surfaces and allow the heavy duty cleaner  
to remain in contact with the exposed surfaces for approximately ten  
minutes. Rinse off surfaces using the shower wand, adjusted to spray  
position.  
Removing Calcium Deposits, Scale and Lime Build-up  
Spray a commercially available cleaner (full strength) for the intended application on all surfaces to be cleaned. Allow the cleaner to remain in contact  
with surfaces for at least five minutes to as long as 12 hours. Rinse off surfaces using the shower wand, adjusted to the spray position. Use the cleaner  
according to the manufacturer's instructions.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 OPERATING INSTRUCTIONS  
5.3 Opening/Closing the Tub Door  
Door Handle Safety Pin  
WARNINGS  
ƽ
DO NOT open the door when water is in the tub,  
serious injury could result.  
Model 3602GXL  
DO NOT fill or use the tub if the door does not lock  
- otherwise serious injury or damage may occur.  
Opening the Tub Door  
1. Place one hand on top of the door handle.  
Door  
2. Use the other hand to pull the safety pin out and release the door  
handle.  
Model 3652  
3. Lift up on the door handle and open the door.  
Safety Pin  
Closing the Tub Door  
1. Close the door.  
2. Push down on the door handle to lock the door into position.  
3. Lift the door handle to ensure the safety pin has engaged the door  
properly.  
Door Handle  
Door  
4. If the door handle lifts, repeat STEPS 1-3.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 OPERATING INSTRUCTIONS  
5.4 Shoulder and Waist Straps  
The shoulder and waist straps are a positioning guide only. They are not designed for use as a safety device or as a restraint.  
The straps MUST be washed and disinfected after each use. Refer to Cleaning and Disinfecting on page 23.  
Installation  
On each end of the straps, insert the lead into the round portion of the slot in the attachment point, slide the lead up and turn it.  
Use  
1. Pass the right end of the shoulder strap under the right arm pit and across the chest Pass the left end of the shoulder strap under the left arm  
pit and around the resident. Secure the ends together with the plastic clasp.  
2. Bring both ends of the waist strap around the resident. Secure the ends together with the plastic clasp.  
3. Adjust the straps for comfort as necessary.  
Strap attachment point  
Strap  
Attachment  
Point  
Waist Strap shown in place  
(attached to tub shell in two places)  
Tub Shell  
Strap Lead  
Plastic clasp  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 OPERATING INSTRUCTIONS  
5.5 Water Temperature Setting  
WARNING  
ƽ
The causes, symptoms and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of  
the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia include an  
increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:  
Failure to perceive heat  
Failure to recognize the need to exit the spa or hot tub  
Unawareness of impending hazard  
Fetal damage in pregnant women  
Physical inability to exit the spa or hot tub  
Unconsciousness resulting in the danger of drowning  
The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia.  
Flow Water Thermometer - measures the temperature of water coming from the tub fill spout or shower/massage wand.  
Water Temperature Control Valve - sets and maintains constant temperature for all incoming water.  
Flow Water  
Thermometer  
Hot (RED)  
Cold (BLUE)  
Water Temperature  
Control Valve  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 OPERATING INSTRUCTIONS  
5.6 Filling the Tub  
DANGER - RISK OF SCALDING  
ƽ
Check that the water temperature is between 95° and 105°F (35°C and 41°C) to avoid scalding the resident. Monitor the incoming  
water temperature on the flow water thermometer. ALWAYS hand test the incoming water temperature and the water temperature in  
the tub.  
WARNING  
ƽ
DO NOT stand in the tub. The tub surfaces are slippery when wet. Serious injury may occur.  
1. Close the drain with the blue stopper.  
2. Push the tub fill button to start the auto tub fill.  
The tub will fill to a predetermined level. To stop the tub from filling, press the fill button a second time (there will be a 5 second  
delay). After the tub has auto-filled, push in and hold the tub fill button to add additional water.  
3. Use the water temperature control valve to adjust the water temperature while watching the flow water thermometer. Test the water  
temperature with your hand.  
4. After the tub has auto-filled, push in and hold the tub fill button to add additional water.  
5.7 Using the Shower/Massage Wand  
Make sure that the Shower/Massage wand is in the holster and the shower wand head is over the tub. The angle of the wand holster  
can be adjusted to accommodate the user’s needs.  
1. Turn the shower/massage on by pushing the ON/OFF button.  
2. Adjust the water temperature using the water temperature valve while watching the flow water thermometer. Test the water temperature with  
your hand.  
3. Adjust the flow of the water by turning the flow control.  
4. Adjust the shower spray by rotating the shower wand head.  
5. Turn the shower/massage off by pressing the ON/OFF button again.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 OPERATING INSTRUCTIONS  
Refer to the following chart for shower head adjustment settings.  
Stream  
Pulse Massage  
Shower Spray  
Mixture of Shower Spray and Pulse Massage  
Flow Control serves as a volume control and water saver.  
The use of the Flow Control permits the reduction of water flow without the need for readjustment of water temperature during bathing.  
A trickle of water through the Flow Control when in the closed position is normal.  
5.8 Using the Whirlpool Function  
1. If the water level does not cover the whirlpool jets, push the tub fill button to auto-fill the tub.  
2. After the water level covers the whirlpool jets and after bathing the resident, add Invacare Defoamer to the bath water. Refer to the Defoamer  
bottle for directions.  
3. Push the whirlpool button to start whirlpool jets. After use, press the whirlpool button again to stop the whirlpool jets.  
4. Drain the tub completely.  
5. Transfer the resident from the tub.  
6. Clean and disinfect the tub, including the door seal. Refer to Cleaning and Disinfecting on page 23.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6 INSPECTION AND TROUBLESHOOTING  
6 Inspection and Troubleshooting  
If any part of the system is not functioning properly, DO NOT use the system. For parts and technical service information please contact ICCI  
Technical Service at (800) 668-2337, Extension 2.  
6.1 Safety Inspection Checklists  
Every six months or as necessary have a qualified technician perform a thorough inspection and servicing. Routine  
maintenance will extend the life and efficiency of your tub.  
Initially  
Ensure that the maximum water supply temperature does not exceed 110°F.  
Ensure that the maximum water pressure does not exceed 55 PSI.  
Verify the water flow temperature with a separate thermometer.  
Visually inspect for cracks in the tub surface.  
Ensure that the door handle locks the door closed.  
Ensure that the safety pin properly engages the door.  
Check that all labels are present and legible. Replace if necessary.  
Before Each Use  
Ensure that the maximum water fill temperature does not exceed 110°F (43° C).  
Ensure that the maximum water pressure does not exceed 55 PSI.  
Visually inspect for cracks in the tub surface.  
Ensure that the door handle locks the door closed.  
Ensure that the safety pin properly engages the door.  
Every Six Months  
Verify the water flow temperature with a separate thermometer.  
Check that all labels are present and legible. Replace if necessary.  
Clean the Water Temperature Control Valve to remove lime deposits.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6 INSPECTION AND TROUBLESHOOTING  
6.2 Troubleshooting  
If problems are not remedied, contact technical support at 1-800-668-2337, Extension 2.  
SYMPTOMS  
FAULTS  
SOLUTION  
Check and reset breaker  
Hydromassage System  
System will not start  
No electrical power to tub  
Switch air hose disconnected  
Water deposits in whirlpool jets  
Reconnect hose to switch and controller  
Disassemble and clean whirlpool jets  
System is ineffective  
System is noisy  
Whirlpool jets are turned on without water  
completely covering the jet assemblies  
Turn off the whirlpool jets. Add water to the tub to  
completely cover the jet assemblies and test the whirlpool  
function again.  
Tub Operation  
No water flow  
Water supply turned off  
Turn on water supply  
Restricted water flow  
Water temperature control valve  
Inspect and clean the water temperature control valve.  
Search for Model 3371 ExactTemp Temperature Control  
Valve, Service Manual Number 153768.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6 INSPECTION AND TROUBLESHOOTING  
6.3 Maintenance Record  
DATE  
MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED  
NOTES  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6 INSPECTION AND TROUBLESHOOTING  
DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED  
NOTES  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 INSPECTION AND TROUBLESHOOTING  
DATE  
MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED  
NOTES  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Invacare Corporation  
USA  
Manufacturing Location  
899 Cleveland Street  
Elyria, Ohio 44036  
© 2011 Invacare Corporation. All rights  
reserved. Republication, duplication or  
modification in whole or in part is prohibited  
without prior written permission from Invacare.  
Trademarks are identified by ™ and ®. All  
trademarks are owned by or licensed to  
Invacare Corporation or its subsidiaries unless  
otherwise noted.  
One Invacare Way  
Elyria, Ohio USA  
44036-2125  
Canada  
994 Hargrieve Road  
London, Ontario  
Canada N6E IP5  
Dispatch is a registered trademark of The  
Chlorox Company.  
Customer Service  
1-800-668-2337  
Technical Support  
1-800-668-2337,  
Extension 2  
Sanijet and Pipeless TM are registered  
trademarks of Maple Industries, LLC, d.b.a.  
Sanijet.  
ExactTemp is a registered trademark of Moen  
Incorporated.  
Betadine is a registered trademark of Purdue  
Pharma LP.  
For more information regarding Invacare products, parts, and Part No. 1167457  
Rev C - 12/11  
Invacare Continuing Care, Inc. is a subsidiary of Invacare  
Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Ingersoll Rand Nail Gun 1077XPA User Manual
JBL Speaker PSW D112 User Manual
JVC CD Player KD AHD59 User Manual
JVC Digital Camera GR AX937 User Manual
JVC Projection Television HD 56G786 User Manual
JVC Security Camera TK S241U User Manual
Kawasaki Oven J8472 User Manual
Kenmore Washer 11012502100 User Manual
Kenwood Car Video System DDX3048 User Manual
Koss Stereo Receiver KS5845 2 User Manual