(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
IMPORTANT
SAFETY RULES
Read, Understand, and Follow all
Instructions Carefully before
Installing and using this Product.
Krystal Clear™
Model 634 Filter Pump
220 - 240 V~, 50 Hz, 360 W
Hmax 1.5 m, H min 0.19 m, IPX4
Max. Water Temperature 35 °C
For illustrative purposes only.
Don’t forget to try these other fine Intex products: Pools, Pool Accessories,
Inflatable Pools and In-Home Toys, Airbeds and Boats available at fine
retailers or visit our website.
©2006 Intex Marketing Ltd. - Intex Development Co. Ltd. - Intex Recreation Corp.
All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle
Rechte vorbehalten.
Printed in China/Imprimé en Chine/Impreso en China/Gedruckt in China.
®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous
licence de/Marcas registradas utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen
Ländern der Welt in Lizenz von/Intex Marketing Ltd. to/à/a/an Intex Development Co. Ltd., 8th Floor, Dah Sing
Financial Centre, 108 Gloucester Road, Wanchai, Hong Kong & Intex Recreation Corp., P.O. Box 1440, Long Beach,
CA 90801 • Distributed in the European Union by/Distribué dans l’Union Européenne par/Distribuido en la unión Europea
por/Vertrieb in der Europäischen Union durch/Intex Trading B.V., P.O. Box nr. 1075 – 4700 BB Roosendaal – The
Netherlands
110**-A0-0701
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
IMPORTANT SAFETY RULES
Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
• To reduce the risk of injury, do not permit children to use this product. Always
supervise children and those with disabilities.
• Risk of electric shock. Connect this product only to a grounding type receptacle
protected by a ground-fault circuit interrupter (GFCI) or residual current device
(RCD). Contact a qualified electrician if you cannot verify that the receptacle is
protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD,
which has a maximum rate of 30mA. Do not use a portable residual current device
(PRCD).
• Do not bury electrical cord. Locate cord where it will not be damaged by lawn
mowers, hedge trimmers, and other equipment.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
• To reduce the risk of electric shock, do not use extension cords, timers, plug
adaptors or converter plugs to connect unit to electric supply; provide a properly
located outlet.
• Assembly and disassembly by adults only.
• Do not attempt to plug in or unplug this product while standing in water or when
your hands are wet.
• Position this product away from pool to prevent a child from climbing on pump to
access the pool.
• Children must stay away from this product and electrical cord(s).
• Do not operate this product when pool is occupied.
• Always unplug this product from the electrical outlet before removing, cleaning,
servicing or making any adjustment to the product.
• This product is for use with storable pools only. Do not use with permanently
installed pools. A storable pool is constructed so that it may be readily
disassembled for storage and reassembled to its original configuration.
• Keep this product more than 2m away from the pool.
• Keep this product more than 3.5m away from the pool (for France only).
• Keep the plug of this product more than 3.5m away from the pool.
• The plug shall be accessible after product installed.
• This product is intended to be used only for the purposes described in the manual!
FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN
PROPERTY DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR
OTHER SERIOUS INJURY OR DEATH.
These product warnings, instructions and safety rules provided with the product represent
some common risks of water recreation devices and do not cover all instances of risk and
danger. Please use common sense and good judgement when enjoying any water activity.
Page 3
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
PARTS LIST
1
2
5
8
3
4
6
9
7
10
11
14
12
15
13
16
NOTE: Drawings for illustration purpose only. May not reflect actual product. Not to scale.
SAVE THESE INSTRUCTIONS
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
PARTS REFERENCE
Before assembling your product, please take a few minutes to check the contents
and become familiar with all the parts.
1
2
3
4
5
6
7
8
3
2
NOTE: Drawings for illustration purpose only. May not reflect actual product. Not to scale.
DESCRIPTION
THREADED FILTER HOUSING COLLAR
AIR RELEASE VALVE/SEDIMENT RELEASE VALVE
VALVE O-RING
REF. NO.
QTY. SPARE PART NO.
1
2
3
4
5
6
7
8
1
2
2
1
1
1
1
2
10491
10460
10264
10490
10492
FILTER HOUSING COVER
FILTER HOUSING O-RING
FILTER CARTRIDGE (59905)
AIR RELEASE VALVE B (WITH O-RING)
PUMP HOSE WITH NUTS
10725
10494
When ordering parts, be sure to quote the model number and part numbers.
Page 5
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
PARTS REFERENCE (continued)
Before assembling your product, please take a few minutes to check the contents
and become familiar with all the parts.
11
12
13
14
15
9
10
16
NOTE: Drawings for illustration purpose only. May not reflect actual product. Not to
scale.
DESCRIPTION
PLUNGER VALVE (HOSE O-RING & STEP WASHER INCLUDED)
HOSE O-RING
REF. NO.
QTY. SPARE PART NO.
9
2
10747
10262
10745
10256
10255
10744
10253
10
11
12
13
14
15
STEP WASHER
STRAINER NUT
FLAT STRAINER RUBBER WASHER
THREADED STRAINER CONNECTOR
STRAINER GRID
LARGE STRAINER (COMBINATION OF STRAINER NUT, FLAT
STRAINER RUBBER WASHER, THREADED STRAINER
CONNECTOR & STRAINER GRID)
16
2
10746
Page 6
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
STRAINER & PLUNGER VALVE SET-UP
The Krystal Clear™ filter pump assembly includes two strainer-control
mechanisms that are to be installed in the pool liner’s two pre-cut holes. The
strainer grid prevents large objects from jamming and/or damaging the filter
pump and the plunger valve assembly prevents water from flowing into the
filter pump while the filter cartridge is being placed or cleaned. For Easy
Set™ Pools, install the strainer and plunger valve before inflating the pool
liner top ring.
1. Grasp the strainer and plunger valve
1
mechanism.
2
2. In a counter-clockwise motion unscrew
plunger valve union from the threaded
strainer connector (14). Be careful not
to lose the step rubber washer (11).
Place the plunger valve on the ground
1
in a safe place (see drawing 1).
3. In a counter-clockwise motion unscrew
the strainer nut (12) from the threaded
connector (14). Leave the flat
2
3
INSIDE
LINER WALL
washer (13) on the connector (14).
4. From the inside of the pool liner insert
the connector (14) into one of the
pre-cut holes with the washer remaining
on the connector to be placed against
the inside of the liner wall.
5. With the flat side of the strainer nut (12)
facing the outside wall of the liner in a
clockwise motion screw the strainer
nut (12) back onto the threaded
12
13 14 15
connector (14) (see drawing 2). Before
assembly, lubricate the threads with a
petroleum jelly.
1
6. Finger tighten the strainer grid (15) and
the strainer nut (12) onto the threaded
connector (14).
2
7. Grasp the plunger valve assembly. Make
sure the step washer (11) is in place.
8. In a clockwise motion screw the plunger
valve union back onto the threaded
connector (14) (see drawing 3).
4.1
INSIDE
LINER
WALL
1
2
9. Examine the plunger valve to see if the
handle is pushed fully down to the "0/1"
position. If not, then grasp the handle at
the top and push down turning the
handle in a clockwise direction until the
plastic protruding notch anchors in
the "0/1" position. This will prevent
water from flowing out during filling
(see drawings 4.1 & 4.2).
4.2
10. Repeat steps 1 through 9 for the 2nd
liner pre-cut hole.
11. The pool liner is now ready to fill with
water. Consult the above-ground-pool
owner’s manual for filling instructions.
Page 7
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
FILTER PUMP HOSE CONNECTION SET UP
1. Remove the Krystal Clear™ filter pump and hoses from the packaging.
2. Place the filter pump in a location for hose (8) connections to the plunger valve
assemblies.
Note: Some regional regulations may require the filter pump to be
mounted on a stationary platform. There are two mounting holes located
in the pump base for this reason. Consult your local authorities for
filter-pump mounting requirements.
3. Grasp the two pump hoses (8) and connect the hose nuts to the filter pump.
4. In a counter-clockwise motion unscrew the threaded filter housing collar (1)
from the filter housing. Place it in a safe place.
5. The Filter Pump is an airtight system. In a counter-clockwise motion turn both
air release valves (2 & 7) 1 - 2 turns to open. DO NOT remove air release
valves as water will expel with force if the motor is turned on and injury
may occur.
6. Grasp and remove the filter housing cover (4). Check to see if a cartridge is
inside the housing. If yes, replace the cover, finger tighten the housing collar (1)
back onto the filter housing.
7. Gently finger tighten the sediment release valve located at the bottom of the
housing to be sure that water does not leak out.
8. When the pool is filled connect the hose from the bottom of the filter housing to
the highest strainer assembly. The hose connection is made at the bottom of
the plunger valve assembly. Use the hose nut to attach the hose.
9. Connect the 2nd hose to the middle of the motor housing and to the remaining
liner connection.
WARNING
Position this product away from pool to prevent a child from
climbing the pool.
WATER LEVEL
PLUNGER VALVE
ASSEMBLY
HOSE NUT
OUTLET HOSE
STRAINER
FILTER HOUSING
COVER
INSIDE
LINER WALL
AIR RELEASE
VALVE
FILTER HOUSING
COLLAR
STRAINER
MOTOR
HOUSING
FILTER CARTRIDGE
INSIDE
INLET HOSE
POWER CORD
HOSE O-RING
OUTSIDE
LINER WALL
(ILLUSTRATION NOT TO SCALE)
Page 8
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
OPERATING INSTRUCTIONS
1. Make sure the filter pump switch is "OFF". The switch is located on the motor
housing.
2. Connect the power cord to a GFCI protected electrical outlet.
WARNING
Risk of electric shock. Connect this product only to a grounding type
receptacle protected by a ground-fault circuit interrupter (GFCI) or residual
current device (RCD). Contact a qualified electrician if you cannot verify
that the receptacle is protected by a GFCI/RCD. Use a qualified electrician
to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a
portable residual current device (PRCD).
IMPORTANT
To prevent air lock, open the lower plunger valve (connected inlet hose)
first and then the upper plunger valve (connected outlet hose). Open air
release valves, wait until water starts to flow out of the air release valves,
close air release valves.
3. Grasp a plunger valve handle. Turn the handle counter-clockwise, pull up until
it stops, and then turn it clockwise until the metal protruding notch anchors in
the "0/1" position. Repeat for the 2nd plunger valve. This opens the valves to
allow water to flow into the filter pump.
4. With water flowing into filter pump, the water pressure will allow the air trapped
inside to escape from the air release valves (2 & 7). When all the air has
escaped water will flow out of the valves (2 & 7). When this occurs gently finger
tighten the valves (2 & 7) in a clockwise direction.
5. Turn the switch "ON". The filter pump is now filtering the water.
6. Operate the filter pump until the desired water clarity is obtained.
FILTER CARTRIDGE CLEANING OR REPLACEMENT
It is recommended that the filter cartridge be replaced at least
every 2 weeks.
1. Make sure the filter pump is turned off, and disconnect the power cord from the
electrical outlet.
2. Grasp a plunger valve handle. Turn the handle counter-clockwise, push down
until it stops and then turn it clockwise until the plastic protruding notch anchors
in the "0/1" position. Repeat for the 2nd plunger valve. This prevents the water
from flowing out of the pool.
3. Gently turn the top air release valve 1-2 turns in a counter-clockwise direction.
This will allow the housing cover to be easily removed.
4. In a counter-clockwise direction remove the filter housing collar (1). Place it in a
safe location.
5. Remove the housing cover (4).
Page 9
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
FILTER CARTRIDGE CLEANING OR REPLACEMENT (continued)
6. Remove the "OLD" filter cartridge.
7. Examine the inside of the filter housing.
8. If dirt or sediment is located on the bottom of the housing then:
A. In a counter-clockwise motion gently unscrew and remove the sediment
valve (2) located at the bottom of the housing. Place it in a safe place.
B. With a bucket of water or a garden hose pour water into the housing
flushing out the sediment.
C. In a gentle clockwise motion return the sediment valve (2) to its location.
Do not over-tighten.
9. Place a new cartridge filter in the housing.
10. Return the housing cover (4) to its position and in a clockwise direction rescrew
the housing collar (1) onto the filter housing.
11. Turn both plunger valve handles in a counter-clockwise direction, pull up until
they stop, and then turn them clockwise until the metal protruding notch
anchors in the "0/1" position.
12. When the trapped air has escaped through the air release valve gently
retighten the valve (2) in a clockwise direction.
13. Reconnect the power cord.
14. Turn the pump "ON".
FILTER PUMP STATIONARY MOUNTING OPTION
Some countries, especially in the European community, require the filter-pump to
be secured to the ground or to a base in a permanent upright position. Check your
local authorities to determine if there is a regulation in your area regarding
above-the-ground swimming pool filter-pumps. If yes, then the filter-pump can be
mounted to a platform using the two holes located in the base. See drawing below.
The filter-pump can be mounted on a cement base or onto a wooden platform to
prevent accidental falling over. Total assembly must exceed 18kg. The European
norm EN 60335-2-41 requires this product be secured to the ground or to a base.
1. The mounting holes are 6.4 mm in diameter and spaced 165 mm apart.
2. Use two bolts and lock nuts with a maximum of 6.4 mm in diameter.
Page 10
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
POOL CARE AND CHEMICALS
•
All pools require care to keep the water clear and hygienically clean. With
proper chemical control, your filter will help attain this objective. Consult your
pool supply dealer for instructions regarding the proper use of chlorine,
algaecide and other chemical agents required for sparkling clear water.
Keep pool chemicals away from children.
•
•
Do not replenish chemicals in pool while pool is occupied. Skin or eye irritations
could occur.
•
Daily pH checking and chemical treatment of the water is very important and
can not be overemphasized. Chlorine, algaecide and maintenance of proper pH
levels are required when filling the pool as well as during the season. Consult
your local swimming pool supply store for instructions.
•
The season's first filling of the pool may have brackish water requiring extra
water additives and extra filter changes. Do not allow swimming in pool until the
pH level is balanced. Consult your local swimming pool supply store for
instructions.
•
•
Keep spare filter cartridges on hand. Replace cartridges every two weeks.
Chlorinated water may damage lawns, gardens or shrubbery as children play
in the pool and splash water outside the pool. Lawn areas underneath the
pool liner will be destroyed. Note that some types of grass may grow through
the liner but function is not affected.
•
Filter run time depends on pool size, weather and usage level. Experiment with
various run times so as to produce clean clear water.
CAUTION
Concentrated chlorine solutions may damage the pool liner. Always
follow the chemical manufacturer’s directions, and the health and hazard
warnings.
Page 11
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
LONG TERM STORAGE
1. Before emptying your pool for long term storage, or relocation, be sure the
water is directed towards an acceptable drain water receptacle away from the
house. Check local regulations for specific directions regarding disposal of
swimming pool water.
2. Disconnect power cord from electrical outlet.
3. After pool is empty of all water disconnect all hoses from pump and plunger
valves and remove strainers from pool wall.
4. Drain all water from inside filter pump.
5. Leave filter pump pieces & hoses outside to thoroughly air dry.
6. Twist the plunger collar counter-clockwise removing the water flow control
mechanism from the plunger housing.
7. Coat the following O-rings and washers with petroleum jelly for long term
storage:
•
•
•
•
•
Air release valve & sediment O-rings (3).
Filter housing cover O-ring (5).
Pump hose O-rings (10).
Strainer valve assembly step washers (11).
Flat strainer rubber washers (13).
8. Discard "OLD" used filter cartridge. Have 1-2 new cartridges available for next
season’s use.
9. Place all dry pieces in the original packaging for storage or place in an airtight
plastic bag.
10. Store the filter pump and accessories in a dry, cool storage location.
Page 12
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
TROUBLESHOOTING GUIDE
TROUBLE
CHECK
POSSIBLE SOLUTIONS
FILTER MOTOR
FAILS TO START
• Not plugged in.
•
Filter cord must be plugged into a 3 wire
outlet that is protected by a Class A
Ground Fault Circuit Interrupter, or RCD.
• Fuse box needs checking.
• GFCI/RCD circuit breaker
tripped.
• Reset circuit breaker. If circuit breaker
trips repeatedly, your electrical system
may have a defect. Turn off circuit
breaker and call an electrician to
correct the problem.
• Motor too hot and overload protection
shut motor off. Let motor cool down.
FILTER DOESN’T
CLEAN POOL
• Improper chlorine or pH
levels.
• Filter cartridge dirty.
• Cartridge damaged.
• Excessively dirty pool.
• Strainer screen restricting
flow.
•
Adjust chlorine and pH level. Consult
your local swimming pool supply stores.
• Clean or replace cartridge.
• Check for holes in cartridge. Replace
if damaged.
• Operate filter for longer periods.
• Clean strainer screen at pool wall inlet.
FILTER DOESN’T
PUMP WATER OR
FLOW IS VERY
SLOW
• Inlet/discharge clogged.
• Air leak on intake line.
• Scale or buildup on cartridge.
• Excessively dirty pool.
• Filter cartridge dirty.
• Look for obstructions in intake hose or
discharge hose inside pool wall.
• Tighten hose nuts, check hoses for
damage, check pool water level.
• Replace cartridge.
• Clean cartridge more often.
• Clean inside plunger valve.
•
Pull valve handle to full upright position.
PUMP DOESN’T
WORK
• Low water level.
• Fill pool to correct water level.
• Clean strainer screens at pool inlet.
• Tighten hose nuts, check hose for damage.
• Check & clear any sticks or leaves in
intake to pump.
• Strainer screen plugged up.
• Air leak on intake hose.
• Faulty motor or impeller
jammed.
• Air lock inside cartridge
chamber.
• Turn & pull valve handle to full upright
position.
TOP COVER
LEAKING
• O-ring missing.
• Cover not tight.
• Filter cartridge dirty.
• Remove cover & check for O-ring.
• Tighten cover (Manually).
• Replace or clean cartridge.
HOSE LEAKING
AIR LOCK
• Hose nuts.
• Tighten/reinstall hose nut.
• Pump housing and inlet hose
air trapped.
• Inlet and outlet hoses
connection reversed.
•
Open air release valves, wait until water
starts to flow out of the air release
valves, close air release valves.
• Lower position of pool outlet connect
to filter pump water inlet, upper
position of pool inlet connect to filter
pump water outlet.
IMPORTANT
If you continue to experience difficulty, please contact our
Consumer Service Department for assistance. See back cover for
contact information.
Page 13
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
COMMON POOL PROBLEMS
PROBLEM
DESCRIPTION
CAUSE
REMEDY
ALGAE
• Greenish water.
• Green or black
spots on pool liner.
• Pool liner is
• Chlorine and pH levels • Super chlorinate with shock
need adjustment.
treatment. Correct pH to your
pool store's recommended
level.
slippery and/or has
a bad odor.
• Vacuum pool bottom.
• Maintain proper chlorine
level.
COLORED
WATER
• Water turns blue,
brown, or black
when first treated
with chlorine.
• Copper, iron or
manganese in water
being oxidized by the
added chlorine.
Common.
• Adjust pH to recommended
level.
• Run filter until water is clear.
• Clean cartridge frequently.
SUSPENDED
MATTER IN
WATER
• Water is cloudy or
milky.
• "Hard water" caused
by pH level being too
high.
• Chlorine content is low.
• Foreign matter in
water.
• Correct pH. Check with pool
dealer for water treatment.
• Check for proper chlorine
level.
• Clean or replace your filter.
CHRONIC
LOW WATER
LEVEL
• Level is lower than
on previous day.
• Rip or hole in pool
liner or hoses. Tighten
caps.
• Repair with patch kit.
• Finger tighten all caps.
SEDIMENT
ON POOL
BOTTOM
• Dirt or sand on
pool floor.
• Heavy use, getting in
and out of pool.
• Use Intex pool vacuum to
clean bottom of pool.
SURFACE
DEBRIS
• Leaves, insects
etc.
• Pool too close to
trees.
• Use Intex pool skimmer.
Page 14
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
GENERAL AQUATIC SAFETY
Water recreation is both fun and therapeutic. However, it involves
inherent risks of injury and death. To reduce your risk of injury, read
and follow all product, package and package insert warnings and
instructions. Remember, however, that product warnings, instructions
and safety guidelines cover some common risks of water recreation,
but do not cover all instances or risk and or danger.
For additional safeguards, also familiarize yourself with the following
general guidelines as well as guidelines provided by nationally
recognized Safety Organizations:
• Demand constant supervision.
• Learn to swim.
• Take the time to learn CPR and first aid.
• Instruct anyone who is watching your children about potential pool
hazards and about the use of protective devices such as locked doors,
barriers, etc.
• Teach children what to do in case of an emergency.
• Always use common sense and good judgement when enjoying any
water activity.
• Supervise, Supervise, Supervise.
Page 15
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
LIMITED WARRANTY
PARTS LIST
Your Krystal Clear™ Filter-Pump has been manufactured using the highest quality
materials and workmanship. All Intex products have been inspected and found free of
defects prior to leaving the factory. This Limited Warranty applies only to the Krystal
Clear™ Filter-Pump.
The provisions of this Limited Warranty apply only to the original purchaser and is not
transferable. This Limited Warranty is valid for a period of one (1) year from the date of the
initial retail purchase. Keep your original sales receipt with this manual, as proof of
purchase will be required and must accompany warranty claims or the Limited Warranty is
invalid.
If a manufacturing defect is found within this one (1) year period, please contact the
appropriate Intex Service Center listed in this manual. The Service Center will determine
the validity of the claim.
IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN
NO EVENT SHALL INTEX, THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE
TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL
DAMAGES OR LIABILITIES.
This Limited Warranty does not apply if the Krystal Clear™ Filter-Pump is subject to
negligence, abnormal use or operation, accident, improper operation, improper voltage or
current contrary to operating instructions, or to damage by circumstances beyond Intex’s
control, including but not limited to, ordinary wear and tear and damage caused by
exposure to fire, flood, freezing, rain, or other external environmental forces. This Limited
Warranty applies only to those parts and components sold by Intex. The Limited Warranty
does not cover unauthorized alterations, repairs or disassembly by anyone other than Intex
Service Center personnel.
The costs associated with the loss of pool water, chemicals or water damage are not
covered by this warranty. Injury or damage to any property or person is not covered by this
warranty.
Page 16
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
For service questions or to order replacement parts, please contact the appropriate office
questions.
AREAS
LOCATION
AREAS
LOCATION
COMEXA S.A
SAN IGNACIO 0201, PARQUE
INDUSTRIAL PORTEZUELO,
QUILICURA, SANTIAGO, CHILE
TEL: 56-2-339 9000
•
CHILE / ARGENTINA /
PERU / URUGUAY
•
ASIA
INTEX DEVELOPMENT CO. LTD.
8TH FLOOR,
DAH SING FINANCIAL CENTRE,
108 GLOUCESTER ROAD,
WANCHAI, HONG KONG
TEL: 852-28270000
FAX: 56-2-339 9022
FAX: 852-23118200
E-mail: [email protected]
SAUDI ARABIAN MARKETING &
AGENCIES CO. LTD.
PRINCE AMIR MAJED STREET,
AL-SAFA DISTRICT. JEDDAH,
KINGDOM OF SAUDI ARABIA
TEL: 966-2-693 8496
E-mail: [email protected]
INTEX TRADING B.V.
POSTBUS 1075, 4700 BB ROOSENDAAL,
THE NETHERLANDS
TEL: 31-(0)165-593939
•
SAUDI ARABIA
•
•
•
•
EUROPE
FRANCE
GERMANY
ITALY
FAX: 31-(0)165-593969
FAX: 966-2-271 4084
E-mail: [email protected]
INTEX SERVICE (FRANCE) SAS
52, ROUTE NATIONALE
39190 BEAUFORT, FRANCE
TEL: 08 90 71 20 39 (0.15 TTC/min)
FAX: 03 84 25 18 09
E-mail: [email protected]
STEINBACH GMBH GERMANY
AN DER WELLE 4
60322 FRANKFURT
E-mail: [email protected]
STEINBACH GMBH AUSTRIA
AISTINGERSTRAßE 2
4311 SCHWERTBERG
TEL: 0800 468397665
FAX: 07262 61439-0
E-mail: [email protected]
INTEX TRADING S.R.O.
BENESOVSKA 23,
101 00 PRAHA 10
CZECH REPUBLIC
TEL: 420-2-717 32247
FAX: 420-2-673 12552
E-mail: [email protected]
N.V. NICOTOY S.A.
•
•
AUSTRIA
CZECH REPUBLIC /
EASTERN EUROPE
TEL: 0800 468397665
FAX: 07262 61439-0
E-mail: [email protected]
A & A MARKETING SERVICE
OFFICE: VIA DEI MESTIERI 8, 20049
CONCOREZZO, MILANO - ITALY
TEL: 39-039-6886260
•
•
BELGIUM
DENMARK
MOESKROENSESTEENWEG 383 C,
8511 AALBEKE
TEL: 0800 92088
FAX: 39-039-6043603
E-mail: [email protected]
WAREHOUSE: C/O ALVI, VIALE DELLA
REPUBBLICA 10 - 27100 PAVIA - ITALY
TOY BROKERS LTD
MARKETING HOUSE,
BLACKSTONE ROAD
HUNTINGDON, CAMBS.
PE29 6EF. UK
TEL: 01480 414361
FAX: 32-56.20.37.61
E-mail: [email protected]
K.E. MATHIASEN A/S
SINTRUPVEJ 12
DK-8220 BRABRAND
DENMARK
TEL: +45 89 44 22 00
FAX: +45 86 24 02 39
E-mail: [email protected]
LEKSAM AB
BRANDSVIGSGATAN 6,
S-262 73 ÄNGELHOLM,
SWEDEN
TEL: +46 431 44 41 20
FAX: +46 431 190 35
E-mail: [email protected]
NORSTAR AS
PINDSLEVEIEN 1
N-3221 SANDEFJORD
NORWAY
TEL: +47 33 48 74 10
•
•
•
UK
FAX: 01480 414761
•
•
•
•
SWEDEN
NORWAY
FINLAND
RUSSIA
E-mail: [email protected]
GWM AGENCY
GARTEN-U. WOHNMÖBEL
RÄFFELSTRASSE 25
POSTFACH
CH-8045 ZURICH/SWITZERLAND
TEL: + 41 - (0)900 - 455 456
FAX: 41 44 455 50 65
E-mail: [email protected]
KOKIDO BVI LIMITED
C/PLOMO 5-7, NAVE 19 POLÍGONO
INDUSTRIAL AIMAYR SAN MARTÍN DE
LA VEGA 28330 MADRID SPAIN
TEL: 34-90-2351045
SWITZERLAND
SPAIN / PORTUGAL
FAX: +47 33 48 74 11
E-mail: [email protected]
NORSTAR OY
RUUKINTIE 20
FIN-02330 ESPOO
FINLAND
TEL: +358 9 8190 530
FAX: +358 9 8190 5335
E-mail: [email protected]
LLC BAUER
KIEVSKAYA STR., 20,
121165 MOSCOW, RUSSIA
TEL: 095-249-9400/8626/9802
FAX: 095-742-8192
E-mail: [email protected]
KATHAY HASTER
UL. LUTYCKA 3,
60-415 POZNAN
TEL: +48 61 8498 381/380
FAX: +48 61 8474 487
E-mail: [email protected]
RECONTRA LTD.
H-1113 BUDAPEST, DARÓCZI ÚT 1-3,
HUNGARY
FAX: 34-91-6912709
E-mail: [email protected]
E-mail: [email protected]
HUNTER OVERSEAS PTY LTD
LEVEL 1, 225 BAY STREET,
BRIGHTON, VICTORIA
AUSTRALIA
•
•
AUSTRALIA
TEL: 61-3-9596-2144 or 1800-224-094
FAX: 61-3-9596-2188
E-mail: [email protected]
HAKA NEW ZEALAND LIMITED
UNIT 5, SENTINEL PARK,
25 AIRBORNE ROAD, ALBANY
PO BOX 302171,
NORTH HARBOUR,
AUCKLAND 1330
NEW ZEALAND
TEL: 649-4159213
FAX: 649-4159212
E-mail: [email protected]
FIRST GROUP TRADING
AL MOOSA GROUP BUILDING, 1ST
FLOOR, OFFICE 102 & 103, UMM HURAIR
ROAD, KARAMA, DUBAI, UAE
TEL: 00971-4-3373322
NEW ZEALAND
•
•
•
POLAND
HUNGARY
BRAZIL
•
•
MIDDLE EAST
REGION
TEL: +361 372 5200/113
FAX: +361 209 2634
E-mail: [email protected]
KONESUL MARKETING & SALES LTDA
RUA INÁCIO BORBA, 835 - CEP. 04715-020,
CHÁCARA SANTO ANTONIO - SÃO
PAULO - SP - BRASIL
TEL: 55 (11) 5183 8866
FAX: 55 (11) 5183 8866
E-mail: [email protected]
FAX: 00971-4-3375115
E-mail: [email protected]
WOOD & HYDE
15-17 PACKER AVENUE, INDUSTRIA 2,
CAPE TOWN, SOUTH AFRICA 7460
TEL: 27-21-0800-204-692
FAX: 27-21-505-5600
SOUTH AFRICA
E-mail: [email protected]
Page 17
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
|