Intel Switch 330T User Manual

Intel® Express 330T  
Stackable Hub  
Quick Start  
English  
Français  
Italiano  
Deutsch  
Español  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Information  
Stack the Hubs  
Up  
4
Hub 1  
Down  
Module  
Module  
Module  
A
A
A
Cascade  
Cascade  
Cascade  
• Unplug the power cords from all the hubs.  
Up  
• Use the included cascade cable to connect the  
hubs. Hubs can be stacked up to five high  
(mixed 16- or 24-port).  
Hub 2  
Down  
Up  
• When properly connected, the entire stack will  
Hub 3  
Down  
act as a single repeater with two segments  
(10Mbps and 100Mbps). The top hub in a stack  
will be numbered hub 1.  
Cascade Cable  
• The hub’s internal bridge automatically bridges  
the 10Mbps and 100Mbps segments (collision  
domains) for the entire stack.  
Stacking Hubs: The cascade cable  
connects from the “Down” connector  
on one hub to the “Up” connector on  
the hub below it.  
Changing MDI/MDI-X  
for Port 1  
5
6
Intel® Express 330T Stackal  
MDI  
1
2
3
4
• All ports on the hub are MDI-X. Pressing the  
MDI/MDI-X button switches Port 1 to MDI so  
you can connect to another hub or switch using  
a straight-through cable.  
MDI-X  
Class II  
• Because the 330T is a Class II hub, never  
daisy-chain a 330T hub to a Class I hub running  
at 100Mbps with UTP cable. Doing so can lead  
to poor network performance.  
MDI/MDI-X  
button  
MDI  
MDI-X  
Intel® Express 300 Series  
Ethernet Module  
Ethernet Module for  
Express 330T Hubs  
(EE300EM)  
Crossover  
Add Optional Modules  
MDI  
MDI-X  
Intel® Express 300 Series Fiber Module  
Duplex  
Fiber Module for  
Express 330T Hubs  
(EE300FX)  
• Both 16- and 24-port 330T hubs can accept  
optional modules (refer to the User Guide).  
Half  
Full  
TX  
RX  
• Use optional modules to manage a stack,  
connect to devices at full duplex, or to extend  
the network to another building or beyond  
100 meters.  
Intel® Express 300 Series  
Management Module  
EIA 232  
009027390005  
MAC Address  
Console: 9600-8-N-1  
Management Module for Express 330T Hubs (EE300MM)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Chinese  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Information  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Korean  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Information  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Démarrage rapide  
Armoire : utilisez les trois  
petites vis pour fixer les  
supports sur le hub.  
Installez le Hub  
1
Retirez le hub et les autres éléments de la  
boîte.  
• Fixez les supports livrés avec le hub si vous  
avez l’intention de monter celui-ci dans une  
armoire.  
® E  
xp  
In  
tel  
res  
s
3
30  
T
S
tac  
ka  
ble  
H
ub  
Mo  
dul  
e
A
MD  
I/  
MD  
I-X  
1
Stat  
us  
2
3
Link\  
Ac  
tiv  
ity  
4
5
Spee  
d
6
Mo  
du  
le  
7
Duplex  
B
8
9
M
od  
ule  
P
10  
rese  
nt  
11  
12  
13  
14  
15  
L
M
ana  
eft  
ge  
d
16  
Lin  
Coll  
is  
ion  
k
ivit  
titio  
=
Sol  
id  
G
ree  
g
link  
s
Act  
Par  
n
y
=
10  
Blin  
kin  
Mb  
ps  
bp  
G
ing  
ree  
Ora  
ned  
n
1
=
B
00M  
S
tatu  
s
s
Rig  
nge  
ht  
10M  
100  
Mb  
ps  
bps  
=
=
S
olid  
O
ff  
Ora  
nge  
• Installez le hub empilable Intel® Express 330T  
dans une armoire ou sur une étagère.  
Cla  
ss  
II  
Etagère : retirez la pellicule  
• Branchez le câble d’alimentation.  
adhésive et placez les supports  
en caoutchouc sous le hub.  
Connectez les  
périphériques  
Du  
Au  
2
3
direct  
10/100  
Hub  
Tous les ports sont configurés de manière  
à détecter automatiquement la vitesse du  
périphérique connecté.  
PC/Serveur  
• Branchez les PC et les serveurs d’impression sur  
le hub à l’aide de câbles directs.  
10/100  
Hub  
Serveur d’impression  
• Utilisez un câble croisé pour connecter le hub  
à un autre hub ou à un commutateur.  
croisé  
10/100  
Hub  
si le port 1 est défini par MDI-X  
• Utilisez un câble direct pour connecter le hub  
à un autre hub ou à un commutateur si le port  
1 est défini par MDI.  
Hub ou commutateur  
direct  
10/100  
Hub  
• Utilisez un câble UTP (paires torsadées non blin-  
dées) CAT 5 pour brancher des périphériques 100  
Mbps. Choisissez un câble UTP CAT 3, 4 ou 5  
pour des périphériques 10 Mbps.  
10/100  
si le port 1 est défini par MDI  
Hub ou commutateur  
Gauche (Vert/Orange)  
Droite (Orange)  
Eteint = 100 Mbps  
Continu = 10 Mbps  
Vert : continu = Liaison valide  
Vert : clignotant = Activité sur le port  
Vérifiez les  
connexions  
• Vérifiez les témoins lumineux à gauche du  
port afin de déterminer l’état de la liaison.  
• Une lumière verte allumée en continu indique  
une liaison valide.  
Orange : clignotant = Partition  
Orange : continu = Désactivé par l’utilisateur  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Etapes facultatives  
Connectez les hubs  
en cascade  
• Débranchez le câble d’alimentation de tous  
les hubs.  
Up  
4
Hub 1  
Down  
Module  
Module  
Module  
A
A
A
Cascade  
Cascade  
Cascade  
Up  
Hub 2  
Down  
• Connectez les hubs en cascade à l’aide du câble  
prévu à cet effet. Vous pouvez combiner jusqu’à  
5 hubs (16 ou 24 ports).  
Up  
Hub 3  
• Lorsque les connexions sont établies correcte-  
ment, la pile fonctionne comme un répéteur uni-  
que reliant deux segments (10 Mbps et 100  
Mbps). Le hub figurant en haut de la pile porte le  
numéro 1.  
Down  
Câble de liaison en cascade  
Connexion des hubs en cascade :  
le câble doit être branché sur le  
connecteur « Bas » d’un hub et  
sur le connecteur « Haut » du hub  
figurant au-dessous.  
• Le pont interne du hub assure la liaison entre le  
segment à 10 Mbps et celui à 100 Mbps (domaine  
de collisions) pour toute la pile.  
Configurez le port 1  
Intel® Express 330T Stackal  
5
6
MDI  
1
2
3
4
MDI-X  
• Tous les ports des hubs sont de type MDI-X.  
Le bouton MDI/MDI-X permet de définir le port  
1 par MDI afin d’y connecter un autre hub ou un  
commutateur à l’aide d’un câble direct.  
Class II  
• Le hub 330T fait partie des appareils de classe II ;  
ne le raccordez jamais par chaînage à un hub de  
classe I fonctionnant à 100 Mbps à l’aide d’un  
câble UTP afin d’éviter une baisse des perfor-  
mances du réseau.  
Bouton  
MDI/MDI-X  
MDI  
MDI-X  
Intel® Express 300 Series  
Ethernet Module  
Module Ethernet pour  
les hubs Express  
330T (EE300EM)  
Crossover  
Ajoutez les modules  
disponibles en option  
MDI  
MDI-X  
Intel® Express 300 Series Fiber Module  
Duplex  
Module Fibre optique  
pour les hubs Express  
330T (EE300FX)  
• Les hubs 330T à 16 et 24 ports permettent la  
connexion de modules disponibles en option  
(consultez le Guide de l’utilisateur).  
Half  
Full  
TX  
RX  
• Ces modules permettent de gérer une pile, de  
connecter des périphériques en mode duplex  
intégral, de relier plusieurs bâtiments ou de  
prolonger le réseau de plus de100 mètres.  
Intel® Express 300 Series  
Management Module  
EIA 232  
009027390005  
MAC Address  
Console: 9600-8-N-1  
Module d’administration pour les hubs Express 330T  
(EE300MM)  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduzione rapida  
A rack: usare le tre  
piccole viti per fissare  
i supporti all’hub.  
Installazione degli  
1
hub  
• Rimuovere l’hub e le altre parti dalla  
confezione.  
• Se si intende montare l’hub a rack, fissare  
i supporti allegati.  
® E  
xp  
In  
tel  
res  
s
3
30  
T
S
tac  
ka  
ble  
H
ub  
Mo  
dul  
e
A
MD  
I/  
MD  
I-X  
1
Stat  
us  
2
3
Link\  
Ac  
tiv  
ity  
4
5
Spee  
d
6
Mo  
du  
le  
7
Duplex  
B
8
9
M
od  
ule  
P
10  
rese  
nt  
11  
12  
13  
14  
15  
L
M
ana  
eft  
ge  
d
16  
Lin  
Coll  
is  
ion  
k
ivit  
titio  
=
Sol  
id  
G
ree  
g
link  
s
Act  
Par  
n
y
=
10  
Blin  
kin  
Mb  
ps  
bp  
G
ree  
Ora  
ned  
n
1
00M  
=
B
S
tatu  
ing  
s
s
Rig  
nge  
ht  
10M  
100  
Mb  
ps  
bps  
=
=
S
olid  
Ora  
nge  
• Installare l’Intel® Express 330T Stackable Hub  
in un rack o su un ripiano.  
O
ff  
Cla  
ss  
II  
Su ripiano: rimuovere la protezione  
dell’autoadesivo dai piedini e farli  
aderire all’hub.  
• Collegare il cavo di alimentazione.  
Collegamento  
dei dispositivi  
Da  
Au  
2
3
diretto  
10/100  
• Tutte le porte sono in grado di rilevare la  
velocità del dispositivo collegato.  
Hub  
PC/Server  
• Collegare i server di stampa e i PC all’hub con  
un cavo diretto.  
10/100  
Hub  
Server di stampa  
Hub o Switch  
• Usare un cavo incrociato per connettere un  
hub a un altro hub o switch.  
incrociato  
10/100  
Hub  
quando la porta 1 viene impostata  
su MDI-X  
• Usare un cavo diretto per la connessione a un  
altro hub o switch quando la porta 1 viene  
impostata su MDI.  
diretto  
10/100  
Hub  
10/100  
• Usare soltanto UTP di CAT 5 per collegare  
i dispositivi a 100 Mbps. Per collegare  
dispositivi a 10 Mbps usare UTP di  
CAT 3, 4 o 5.  
quando la porta 1 viene impostata  
su MDI  
Hub o Switch  
Sinistra (verde/arancione)  
Verde costante = Collegamento  
Verde lampeggiante = Attività  
Destra (arancione)  
Spenta = 100 Mbps  
Accesa costante = 10 Mbps  
Controllo dei  
collegamenti  
• Controllare le spie LED delle porte per  
individuare lo stato del collegamento.  
• Una spia LED accesa con continuità (sulla  
sinistra) indica un collegamento valido.  
Arancione lampeggiante = Partizione  
Arancione costante = Disattivata dall’utente  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Informazioni opzionali  
Hub impilati  
Up  
4
Hub 1  
Down  
Module  
Module  
Module  
A
A
A
Cascade  
Cascade  
Cascade  
• Disconnettere il cavo di alimentazione dagli hub.  
Up  
• Utilizzare il cavo di collegamento in cascata  
incluso per connettere gli hub. È possibile  
impilare fino a 5 hub (misti a 16 o 24 porte).  
Hub 2  
Hub 3  
Down  
Up  
• Se connesso in modo appropriato, l’intero stack  
si comporta come un singolo ripetitore con due  
segmenti (10 Mbps e 100 Mbps). Il primo hub in  
alto sarà l’hub numero 1.  
Down  
Cavo in cascata  
Il bridge interno dell’hub connette automatica-  
mente i segmenti da 10 Mbps e 100 Mbps  
(domini di collisione) in tutto lo stack.  
Hub impilate: il cavo in cascata  
collega il connettore “Down” di un  
hub al connettore “Up” dell’hub  
sottostante.  
Modifica MDI/MDI-X  
della Porta 1  
5
6
Intel® Express 330T Stackal  
MDI  
1
2
3
4
• Tutte le porte dell’hub sono di tipo MDI-X. Se si  
preme il pulsante MDI/MDI-X la Porta 1 diventa  
MDI, ed è possibile collegarla a un altro hub o  
switch usando un cavo diretto.  
MDI-X  
Class II  
• Dato che il 330T è un hub di Classe II, non  
connetterlo mai in daisy-chain (cascata) con un  
hub di Classe I a 100 Mbps con del cavo UTP  
(doppino ritorto non schermato). Questo tipo di  
collegamento provoca un abbassamento delle  
prestazioni della rete.  
Pulsante  
MDI/MDI-X  
MDI  
MDI-X  
Intel® Express 300 Series  
Ethernet Module  
Modulo Ethernet per  
Hub Express 330T  
(EE300EM)  
Crossover  
Aggiunta di moduli  
facoltativi  
• Gli hub 330T, sia quelli a 16 che a 24 porte,  
accettano moduli aggiuntivi (consultare la Guida  
dell’utente).  
MDI  
MDI-X  
Intel® Express 300 Series Fiber Module  
Duplex  
Modulo Fibre per  
Hub Express 330T  
(EE300FX)  
Half  
Full  
TX  
RX  
Intel® Express 300 Series  
Management Module  
EIA 232  
• Utilizzare i moduli opzionali per la gestione  
dello stack, per connettere i dispositivi in full-  
duplex o per estendere la rete ad un’altra  
costruzione o oltre i 100 metri.  
009027390005  
MAC Address  
Console: 9600-8-N-1  
Modulo Management Hub per Express 330T (EE300MM)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Schnellstart  
Rack: Befestigen Sie die  
Klammern mit den drei  
kleinen Schrauben am Hub.  
Installieren des Hubs  
1
• Entnehmen Sie den Hub und die Bauteile aus  
der Schachtel.  
• Befestigen Sie die enthaltenen Klammern,  
wenn Sie den Hub in einem Gestell montieren  
wollen.  
® E  
xp  
In  
tel  
res  
s
3
30  
T
S
tac  
ka  
ble  
H
ub  
Mo  
dul  
e
A
MD  
I/  
MD  
I-X  
1
Stat  
us  
2
3
Link\  
Ac  
tiv  
ity  
4
5
Spee  
d
6
Mo  
du  
le  
7
Duplex  
B
8
9
M
od  
ule  
P
10  
rese  
nt  
11  
12  
13  
14  
15  
L
M
ana  
eft  
ge  
d
16  
Lin  
Coll  
is  
ion  
k
ivit  
titio  
=
Sol  
id  
G
ree  
g
link  
s
Act  
Par  
n
y
=
10  
Blin  
kin  
Mb  
ps  
bp  
G
ing  
ree  
Ora  
ned  
n
1
=
B
00M  
S
tatu  
s
s
Rig  
nge  
ht  
10M  
100  
Mb  
ps  
bps  
=
=
S
olid  
O
ff  
Ora  
nge  
• Installieren Sie den Intel® Express 330T  
Stapelhub in einem Gestell oder Regal.  
Cla  
ss  
II  
Regal: Befestigen Sie die  
Klammern mit den drei kleinen  
Schrauben am Hub.  
• Schließen Sie das Stromkabel an.  
Anschließen  
der Geräte  
2
Von  
Zum  
Direkt  
• Alle Anschlüsse stellen automatisch die Ge-  
schwindigkeit des angeschlossenen Gerätes fest.  
10/100  
Hub  
PC/Server  
• Schließen Sie PCs und Druckserver über eine  
direkte Kabelverbindung an den Hub an.  
10/100  
Verwenden Sie zur Verbindung des Hubs mit  
einem anderen Hub oder Switch ein  
Nullmodemkabel.  
Hub  
Druckserver  
Nullmodemkabel  
Verwenden Sie zur Verbindung mit einem anderen  
Hub oder Switch eine direkte Kabelverbindung,  
wenn Anschluß 1 auf MDI eingestellt ist.  
10/100  
Hub  
wenn Anschluß 1 auf MDI-X  
Hub oder Switch  
Direkt  
Verwenden Sie für den Anschluß von 100 MBs-  
Geräten aussschließlich CAT 5 UTP. Für den  
Anschluß von 10-MB/s-Geräten verwenden Sie  
CAT 3, 4 oder 5 UTP.  
10/100  
Hub  
10/100  
wenn Anschluß 1 auf MDI  
Hub oder Switch  
Links (Grün/Orange)  
Ununterbrochen aufleuchtendes  
Grün = Verbindung  
Rechts (Orange)  
Aus = 100 MB/s  
Ununterbrochen  
Überprüfen der  
Verbindungen  
Blinkendes Grün = Aktivität  
aufleuchtend = 10 MB/s  
3
Überprüfen Sie die Anschluß-LEDs, um den  
Verbindungsstatus zu bestätigen.  
Eine ununterbrochen aufleuchtende grüne  
LED (links) signalisiert eine gültige  
Verbindung.  
Blinkendes Orange = Partitionierung  
Ununterbrochen aufleuchtendes Orange = Benutzer deaktiviert  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Weitere Optionen  
Stapeln der Hubs  
Up  
4
Hub 1  
Down  
Module  
Module  
Module  
A
A
A
Cascade  
Cascade  
Cascade  
• Lösen Sie die Stromkabel von allen Hubs.  
Up  
Verwenden Sie das beiliegende Kaskadenkabel,  
Hub 2  
Down  
um die Hubs miteinander zu verbinden. Es  
können bis zu fünf Hubs übereinandergestapelt  
werden(mit 16- oder 24-poligen Anschlüssen).  
Up  
Hub 3  
• Wenn alle Hubs richtig miteinander verbunden  
Down  
sind, funktioniert der gesamte Spapel als  
Einzelübertrager mit zwei Segmenten (10 MB/s  
und 100 MB/s). Der oberste Hub im Stapel erhält  
die Nummer 1.  
Kaskadenkabel  
Stapeln der Hubs: Mit dem  
Kaskadenkabel wird der Down-  
Anschluß des einen Hubs mit  
dem Up-Anschluß des Hubs  
darunter verbunden.  
• Die interne Brücke des Hubs überbrückt auto-  
matisch die 10-MB/s- und 100-MB/s-Segmente  
(Kollisionsdomänen) für den gesamten Stapel.  
Ändern von MDI/MDI-X  
für Anschluß 1  
Alle Anschlüsse des Hubs sind MDI-X-Anschlüsse.  
Durch Drücken der MDI/MDI-X-Taste wird  
Anschluß 1 auf MDI umgeschaltet, und es kann ein  
anderer Hub oder Switch über eine direkte  
5
Intel® Express 330T Stackal  
MDI  
1
2
3
4
MDI-X  
Class II  
Kabelverbindung angeschlossen werden.  
• Da es sich beim 330T um einen Hub der Klasse II  
handelt, darf ein 330T-Hub niemals per Prioritäts-  
verkettung (Daisychain) mit einem Hub der Klasse I  
mit 100 MB/s und UTP-Kabel verbunden werden.  
Dies kann zu verminderter Netzwerkleistung führen.  
MDI/MDI-X  
Taste  
MDI  
MDI-X  
Intel® Express 300 Series  
Ethernet Module  
Ethernet-Modul für  
Express 330T-Hubs  
(EE300EM)  
Crossover  
Hinzufügen optionaler  
MDI  
MDI-X  
6
Module  
• Optionale Module können sowohl in Hubs mit  
16- als auch mit 24-poligen Anschlüssen  
Intel® Express 300 Series Fiber Module  
Duplex  
Fiber-Modul für  
Express 330T-Hubs  
(EE300FX)  
Half  
Full  
TX  
RX  
installiert werden (siehe Benutzerhandbuch).  
Intel® Express 300 Series  
Management Module  
EIA 232  
Verwenden Sie optionale Module zur Verwaltung  
eines Stapels, Verbindung von Geräten mit  
Vollduplex oder zur Erweiterung des Netzwerks  
zu anderen Gebäuden oder über Entfernungen  
von mehr als 100 m.  
009027390005  
MAC Address  
Console: 9600-8-N-1  
Management-Modul für Express 330T-Hubs (EE300MM)  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Inicio rápido  
Bastidor: Utilice los  
tres tornillos pequeños  
para fijar los soportes  
al concentrador.  
Instalación del  
concentrador  
• Extraiga el concentrador y las piezas de la  
caja.  
1
• Monte los soportes que se incluyen si piensa  
montar el concentrador en un bastidor.  
® E  
xp  
In  
tel  
res  
s
3
30  
T
S
tac  
ka  
ble  
H
ub  
Mo  
dul  
e
A
MD  
I/  
MD  
I-X  
1
Stat  
us  
2
3
Link\  
Ac  
tiv  
ity  
4
5
Spee  
d
6
Mo  
du  
le  
7
Duplex  
B
8
9
M
od  
ule  
P
10  
rese  
nt  
11  
12  
13  
14  
15  
L
M
ana  
eft  
ge  
d
16  
Lin  
Coll  
is  
ion  
k
ivit  
titio  
=
Sol  
id  
G
kin  
B
ree  
g
link  
s
Act  
Par  
n
y
=
10  
Blin  
Mb  
ps  
bp  
G
ing  
ree  
Ora  
ned  
n
1
=
00M  
S
tatu  
®
s
s
Rig  
nge  
ht  
10M  
100  
Mb  
ps  
bps  
=
=
S
olid  
O
ff  
Ora  
nge  
• Instale el concentrador Intel Express 330T  
apilable en un bastidor o en una estantería.  
Cla  
ss  
II  
Estantería: Retire la cobertura  
protectora y fije los soportes  
de goma al concentrador.  
• Conecte el cable de alimentación.  
Conexión de los  
dispositivos  
• Todos los puertos detectan automáticamente la  
velocidad de los dispositivos conectados a ellos.  
2
De  
A
directo  
10/100  
Concentrador  
PC/Servidor  
• Conecte PC y servidores de impresión al  
concentrador con cables directos.  
10/100  
• Utilice un cable cruzado para conectar un  
concentrador a otro concentrador o conmutador.  
Concentrador  
Servidor de impresión  
cruzado  
• Utilice un cable directo para conectar con otro  
concentrador o conmutador cuando el puerto  
1 esté configurado en MDI.  
10/100  
cuando el puerto 1 está  
establecido en MDI-X  
Concentrador  
Concentrador  
o conmutador  
• Utilice sólo CAT 5 UTP para conectar  
a dispositivos de 100 Mbps. Para  
conexiones con dispositivos de 10 Mbps, utilice  
CAT 3, 4, o 5 UTP.  
directo  
10/100  
10/100  
cuando el puerto 1 está  
establecido en MDI  
Concentrador  
Concentrador  
o conmutador  
Izquierda (Verde/Naranja)  
Verde fijo = Enlace  
Verde parpadeante = Actividad  
Derecha (Naranja)  
Apagado = 100 Mbps  
Fijo = 10 Mbps  
Comprobación de las  
3
conexiones  
• Compruebe los LED del puerto para confirmar  
el estado del enlace.  
• Un LED verde fijo (a la izquierda) indica un  
enlace válido.  
Naranja parpadeante = Partición  
Naranja fijo = Inhabilitado por el usario  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Información opcional  
Apilación de los  
concentradores  
Up  
4
Concen-  
trador 1  
Down  
Module  
Module  
Module  
A
A
A
Cascade  
Cascade  
Cascade  
• Desconecte el cable de alimentación de todos  
los concentradores.  
Up  
Concen-  
trador 2  
Down  
• Utilice el cable en cascada para conectar los  
concentradores. Se pueden apilar hasta 5  
concentradores (16 o 24 puertos).  
Up  
Concen-  
trador 3  
Down  
• Cuando se conecta correctamente, todo el conjunto  
actuará como un solo repetidor con dos segmentos  
(10 Mbps y 100 Mbps). El concentrador superior  
de una pila tendrá el nombre de concentrador 1.  
Cable en cascada  
Apilamiento de concentradores:  
El cable en cascada se conecta  
desde el conector “Inferior” de un  
concentrador al conector “Superior”  
del concentrador debajo de éste.  
• El puente interno del concentrador puenteará  
automáticamente los segmentos de 10 Mbps y  
100 Mbps (dominios de colisión) para toda la pila.  
Cambio de MDI/MDI-  
X para el puerto 1  
Intel® Express 330T Stackal  
5
6
MDI  
1
2
3
4
MDI-X  
• Todos los puertos del concentrador son MDI-X. Si  
pulsa el botón MDI/MDI-X cambiará el puerto 1 a  
MDI para poder conectar con otro concentrador o  
conmutador mediante un cable directo.  
Class II  
• El concentrador 330T es de Clase II, por ello,  
nunca conecte en cadena un concentrador 330T  
con un concentrador de Clase I que funcione a 100  
Mbps con un cable UTP. Esto podría causar un  
bajo rendimiento de la red.  
Botón  
MDI/MDI-X  
MDI  
MDI-X  
Intel® Express 300 Series  
Ethernet Module  
Módulo Ethernet para  
concentradores Express  
330T (EE300EM)  
Crossover  
Adición de módulos  
opcionales  
• Los concentradores 330T de 16 y 24 puertos  
pueden aceptar módulos opcionales (consulte  
el Manual del usuario).  
MDI  
MDI-X  
Intel® Express 300 Series Fiber Module  
Duplex  
Módulo de fibra para  
concentradores Express  
330T (EE300FX)  
Half  
Full  
TX  
RX  
Intel® Express 300 Series  
Management Module  
EIA 232  
• Con los módulos opcionales puede gestionar  
una pila, conectar con dispositivos a dúplex  
completo, o ampliar la red a otro edificio  
o más allá de 100 metros.  
009027390005  
MAC Address  
Console: 9600-8-N-1  
Módulo de gestión para concentradores Express 330T  
(EE300MM)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Copyright © 1999,  
Intel Corporation.  
All rights reserved.  
*Other product and corporate names  
may be trademarks of other companies  
and are used only for explanation and to  
the owners’ benefit, without intent to  
infringe.  
Intel Corporation assumes no  
responsibility for errors or omissions in  
this manual. Nor does Intel make any  
commitment to update the information  
contained herein.  
Intel Corporation  
5200 NE Elam Young Parkway  
Hillsboro OR 97124-6497  
Customer Support:  
First Edition  
April 1999  
732040-001  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Infinity Speaker PS210 User Manual
JVC Camcorder LYT2043 001C M User Manual
JVC Digital Camera GR DVM1DU User Manual
JVC Flat Panel Television LT Z26SX5 User Manual
Kathrein Satellite TV System UAS 177 User Manual
Keating Of Chicago Griddle Security Package User Manual
Kenmore Gas Grill 1191623 User Manual
Keys Fitness Fitness Equipment ST DFIDL User Manual
KitchenAid Ice Maker KUIS15NRTBO User Manual
Kodak Printer E2635 User Manual