Intel Server NSW1U User Manual

Intel® IP Network Server  
Intel® NSW1U (1Ux20”D)  
Configuration Guide  
System / Spares / Accessories List  
Rev 1.2  
A reference guide to assist customers and the field in ordering these  
servers, accessories and spares  
~Subject to Change Without Notice~  
NSW1U  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Document Table of Contents  
I.  
CHANGE HISTORY  
6
7
II.  
INTRODUCTION  
III.  
IV.  
V.  
VI.  
PRODUCTION SKUS  
9
PRODUCTION SPARES/ACCESSORY LIST  
ADDING BYPASS ETHERNET PORTS  
DOCUMENTATION  
17  
21  
23  
24  
APPENDIX A. BASE MODEL 0 SYSTEMS CONFIGURATION  
APPENDIX B. RACK MOUNTING OPTIONS FOR 1U AND 2U INTEL®  
COMMUNICATIONS RACK MOUNT SERVERS  
27  
5/18/2007  
v1.2  
3 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I. Change History  
Revision  
1.0  
Date  
Comments  
11/10/2006 Original version.  
1.1  
3/19/2007 Updated at SRA. Added Front NIC Bypass SKU.  
1.2  
5/17/2007 Updated Spares list; new Rack Mount appendix; misc.  
updates  
5/18/2007  
v1.2  
4 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. Introduction  
The Intel® IP Network Server NSW1U system is the first 1U rack mount server to  
join the Intel® IP Network Server family, characterized by having long product  
life and a 20” depth chassis. The NSW1U uses the Dual-Core Intel® Xeon®  
Processor 5100 Series with 4M cache, and supports a number of CPU speeds.  
Intel® IP Network Servers are suited to a host of applications in the network  
security and industrial environment. The server is targeted to applications  
requiring rugged systems including Intrusion Detection, Intrusion Protection,  
Firewall, VPN, SSL VPN, and Application Secure Gateways. It can also support  
manufacturing, industrial, utility and military applications where a rugged,  
highly reliable server is required for harsh environments such as dust, high  
altitude, fire hazard, earthquake propensity, and high ambient temperatures.  
The NSW1U product has several phases before being released for general  
customer availability (SRA – Ship Release Authorization). These phases include a  
Beta, Silver, and Production phase. This document details the options available  
on the Production systems.  
5/18/2007  
v1.2  
5 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. Production SKUs  
Intel IP Network Servers:  
Production NSW1U Server – Rear NIC (AC Supply) - Product Code NSWA0201W  
Production NSW1U Server – Rear NIC (DC Supply) - Product Code NSWD0201W  
Production NSW1U Server – Front NIC (AC Supply) - Product Code NSWA0301W  
Production NSW1U Server – Front NIC with Bypass (AC Supply) - Product Code  
NSWA0401W  
All listed Production SKUs are model 0 SKUs (no CPU, heatsink, memory, hard  
drive or plug-in adapters are provided). Those components must be ordered  
separately as Accessories from Intel or from third party vendors listed in the  
Tested Hardware and Operating System List (THOL). See Appendix A –  
Production SKU Configuration for a list of components included in each  
Production model 0 SKU.  
NSW1U is designed for the Dual-Core Intel® Xeon® Processor 5100 Series with 4M  
L2 cache, and 1066MHz/1333MHz FSB.  
Check the following site for more information on the NSW1U:  
tm  
Intel® Network Server NSW1U support web site:  
Please note the following:  
Please refer to the Intel® IP Network Server NSW1U product  
documentation.  
AC Power cords are not provided with the base system. Customers  
must procure the power cords separately (for AC systems, order the NA  
– North American - power cord as indicated).  
Ensure customers have the appropriate technical support and contact  
before placing the first order.  
The NSW1U base configuration comes with a riser to support 1 PCI-  
Express slot. An optional replacement riser may be ordered to support  
a 1 slot PCI-X.  
5/18/2007  
v1.2  
6 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Special instructions for Ordering of Processors:  
The NSW1U supports a range of processor speeds from 1.6 GHz to 3.0 GHz.  
Ordering details for the CPU for use in NSW1U are listed below, and includes  
both Tray (for OEMs) and Boxed (Retail channel) processors.  
Dual-Core Intel® Xeon® Processors Supported by NSW1U:  
Processor  
Speed  
FSB  
TDP Boxed Processor Tray Processor  
Number  
Product Code  
BX805565160A  
BX805565150A  
BX805565140A  
BX805565130A  
BX805565120A  
BX805565110A  
BX805565148A  
N/A  
Product Code  
HH80556KJ0804M  
HH80556KJ0674M  
HH80556KJ0534M  
HH80556KJ0414M  
HH80556KH0364M  
HH80556KH0254M  
HH80556JJ0534M  
HH80556JH0364M  
5160  
3.00 GHz  
2.66 GHz  
2.33 GHz  
2.00 GHz  
1.86 GHz  
1.6 GHz  
1333 MHz  
1333 MHz  
1333 MHz  
1333 MHz  
1066 MHz  
1066 MHz  
1333 MHz  
1066 MHz  
80W  
65W  
65W  
65W  
65W  
65W  
40W  
40W  
5150  
5140  
5130  
5120  
5110  
LV 5148  
LV 5128  
2.33 GHz  
1.86 GHz  
Notes:  
Although all of the above processors are tested and supported, Intel  
recommends the use of the following processors from Intel’s Infrastructure  
Processor Division (IPD) for long availability and support.  
o 5140 (2.33 GHz, 1333MHz FSB, 65W)  
o 5130 (2.00 GHz, 1333MHz FSB, 65W)  
o LV 5148 (2.33 GHz, 1333MHz FSB, 40W)  
o LV 5128 (1.86 GHz, 1066MHz FSB, 40W)  
The boxed CPUs listed above include a Active/Passive Heatsink Kit.  
Simply remove the fan from the Kit, and install into the system as shown  
in the product documentation.  
For Tray CPUs, you will need to procure a Heatsink Kit (TMWHSNK01W)  
and thermal grease for each processor.  
Note that CPU product codes can change, and that the above is a snapshot  
current as of 5/17/2007. Please consult with your Intel representative for SSpec  
or MM# which may be needed for ordering the CPU. Any differences in  
functionality is reported in Monthly Specification updates available on  
5/18/2007  
v1.2  
7 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Production SKUs that can be ordered (see Appendix A for content of each  
SKU) are listed below.  
PID Order Code  
Description  
MM#  
Minimum  
Order  
Size  
NSWA0201W  
NSWD0201W  
NSWA0301W  
NSWA0401W  
Intel® IP Network Server NSW1U, 1U,  
Rear NIC, Base Model 0*.  
Includes 450W AC Power Supply.  
885432  
885433  
885501  
888296  
1
1
1
1
Intel® IP Network Server NSW1U, 1U,  
Rear NIC, Base Model 0*.  
Includes 450W DC Power Supply.  
Intel® IP Network Server NSW1U, 1U,  
Front NIC, Base Model 0*.  
Includes 450W AC Power Supply.  
Intel® IP Network Server NSW1U, 1U,  
Front NIC with Bypass, Base Model 0*.  
Includes 450W AC Power Supply.  
*Note: See definition of “base model 0” at beginning of section III.  
Power Cords are not included. For AC Power cords, order the power cord below.  
This power cable is RoHS-compliant.  
PID  
MM#  
Comments  
This AC power cable may be ordered by North America  
PWRCABLEUS 816324 (NA) customers. International customers should  
procure their specific power cords directly.  
5/18/2007  
v1.2  
8 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV. Production Spares/Accessory List  
Below are the Spares parts and Accessories that may be ordered with the NSW1U  
system. Any of these parts may be ordered as spares for part replacement  
purposes or as additional customer inventory. Some of the parts below are not  
included in the NSW1U system base model and may be ordered as accessories for  
purposes of upgrading the base model to include additional features.  
Many of these parts are common to the Intel® Carrier Grade Server TIGW1U  
product. For a listing of additional compatible accessories, such as Optical  
Devices for use with the CD-ROM carrier, please refer to the Tested Hardware  
and Operating System List (THOL).  
Included  
in Base  
Model  
PID Order Code  
Description  
Contents  
MM#  
Minimum  
Order  
Size  
(Y/N)  
TIGW1U AC Power Supply  
TIGW1U DC Power Supply  
TIGW1U CPU Heatsink  
Y
TMWACPSU01W  
TMWDCPSU01W  
TMWHSNK01W  
886492  
886537  
887151  
1
1
AC power supply  
one in AC  
SKU  
DC power  
supply, input  
power connector  
Y
one in DC  
SKU  
N
N
12  
Heatsink  
(order in  
multiples of 12)  
Carrier, PBA,  
screws, pwr  
cable, signal  
cable  
Board, cable,  
screws (mini-SD  
flash memory  
not included)  
TIGW1U CD-ROM Carrier; i/f board  
(no drive)  
TMWCDRMC01W  
TMWSYSCON01W  
886842  
886484  
1
1
1
TIGW1U Syscon Board  
N
Intel® Remote Management Module 2  
(RMM2) - Single Pack  
Intel® Remote Management Module 2  
(RMM2) - Bulk Pack (10)  
N
N
RMM2 with GCM  
(single-pack)  
AXXRMM2  
888501  
888498  
AXXRMM2BULK  
1
RMM2 with GCM  
(10-pack)  
(specify ‘1’ for  
each 10-pack)  
Cable, PCI  
NSW1U NIC Cable  
N
NSWDBCBL01W  
886591  
5
Support Bracket,  
escutcheon,  
screws  
(order in  
multiples of 5)  
Riser, screws  
TIGW1U PCI-X Riser  
N
Y
TMWPCIXRSR01W  
TMWPCIERSR01W  
886491  
886490  
1
1
Riser, screws  
TIGW1U PCI-Express Riser  
5/18/2007  
v1.2  
9 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Production Spares/Accessories List (continued)  
Included  
in Base  
Model  
PID Order Code  
Description  
Contents  
MM#  
Minimum  
Order  
Size  
(Y/N)  
Bezel  
Bezel  
NSW1U Bezel - Rear NIC  
Y
NSWFBZL01W  
NSWFBZL02W  
NSWCBLBRK01W  
886614  
886615  
886590  
1
1
one in Rear  
NIC SKU  
NSW1U Bezel – Front NIC  
Y
one in Front  
NIC SKU  
Bracket for  
chassis face  
NSW1U Cable Management Bracket  
N
N
5
(order in  
multiples of 5)  
Escutcheons  
(48-pack)  
NSI2U Fiber Escutcheon packaged in  
cartons of 48  
NSIESCFBR100  
880102  
48  
(order in  
multiples of 48)  
CD filler  
NSW1U CD-ROM filler  
NSW1U SATA HDD Carriers  
NSW1U Fanset  
N
Y
Y
Y
NSWCDFILL01W  
NSWSATAHDD01W  
NSWFANSET01W  
TMWCBL01W  
886841  
886589  
886544  
886613  
1
1
1
1
2 carriers  
Fans, bracket,  
air ducts  
System cables—  
Flex, CD-ROM  
power, CD-ROM  
signal, SATA  
Signal, Front  
Panel Panel,  
Battery  
TIGW1U Cables, CD-ROM power,  
spare  
Board  
TIGW1U Power Distribution Board  
Y
TMWPDB01W  
NSWEFPR01W  
886538  
886540  
1
1
Board, litepipe  
Board, litepipe  
Board  
NSW1U Ethernet Front Panel I/O  
Board - Rear NIC, Litepipe  
Y
one in Rear  
NIC SKU  
NSW1U Ethernet Front Panel I/O  
Board - Front NIC, Litepipe  
Y
NSWEFPF01W  
886543  
886849  
886853  
886812  
1
1
1
1
one in Front  
NIC SKU  
NSW1U Baseboard - Rear NIC  
Y
NSWBSBRDR01W  
NSWBSBRDF01W  
NSWBYPSBRD01W  
one in Rear  
NIC SKU  
Board  
NSW1U Baseboard - Front NIC  
Y
one in Front  
NIC SKU  
Board  
NSW1U Ethernet Front Panel - Front  
NIC with Bypass  
Y
one in Front  
NIC SKU  
5/18/2007  
v1.2  
10 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V. Adding Bypass Ethernet ports  
The NSW1U comes standard with 4 Gb Ethernet ports either in the front or rear  
of the chassis. By adding the Intel® Pro/1000 PT or PF Quad Port Bypass Server  
Adapter, four additional ports of Gbit ethernet (either Copper or Fiber) may be  
added. These NIC adapters may be purchased separately via normal distribution  
channels.  
The Quad Copper NIF Bypass adapters require purchase of the NSWDBCBL01W  
kit, which includes 5 of the NIF cables designed for the NSW1U system, as well as  
the Escutcheons and associated screws to complete the installation of the Bypass  
adapter in the system.  
The Quad Fiber NIF Bypass adapters require purchase of the NSIESCFBR100  
escutcheon accessory.  
Intel LAD NIC Order Codes:  
PID order code  
Description  
MM#  
Minimum  
Order Size  
Quad Copper Gb Bypass NIC,  
5 PACK  
Quad Copper Gb Bypass NIC  
in Front, 5 PACK  
Quad Fiber Gb Bypass NIC, 5  
PACK  
EXPI9014PTBLK  
EXPI9024PTBLK  
EXPI9014PFBLK  
876697  
876699  
876696  
5
5
5
Quad Fiber Gb Bypass NIC in  
Front, 5 PACK  
EXPI9024PFBLK  
876694  
5
Note: For a list of other tested Network Interface Cards (NICs) refer to the  
Tested Hardware and Operating System List (THOL).  
5/18/2007  
v1.2  
11 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VI. Documentation  
More Product Details:  
Check the following web site for more information on the TIGW1U:  
tm  
Support.Intel.Com Users:  
Product information including specifications, compatibility, user’s guides,  
drivers, firmware, and software associated with the Intel® Network Server  
NSW1U is available from Intel Customer Support.  
Intel® Network Server NSW1U support web site:  
If you can not access the documents using the links provided, please contact your  
FAE/FSE for assistance.  
5/18/2007  
v1.2  
12 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A. Base Model 0 Systems Configuration  
All Production SKUs are base model 0 SKUs (no CPU, heatsink, memory, hard  
drive or plug-in adapters are provided). Those components must be ordered  
separately as Accessories from Intel or from third party vendors listed in the  
Tested Hardware and Operating System List (THOL). The below table lists how  
many of each component is included in the Production model 0 SKU.  
NSW1U Production SKU Configuration  
Configuration  
Configuration  
Component Description  
AC SKU  
DC SKU  
Chassis (bezel, sheet metal, top cover, PCI  
carrier)  
1
1
S5000PHB Baseboard  
1
1
(Dual-Core Intel® Xeon® Processor 5100  
Series with 4M L2 cache, and 1066MHz and  
1333MHz FSB) – CPUs not included  
FH-FL Bracket with PCI-Express Riser  
AC power supply (450W)  
DC power supply (450W)  
Power Supply Filler Panel  
SATA HDD Carrier  
1
1
-
1
1
-
1
1
2
2
Server Deployment Toolkit (CD)  
Quick Start Guide  
1
1
1
1
Power cable1  
Purchase separately  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Purchase separately  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
Optional Accessory  
CD-ROM Carrier  
PCI-X Riser2  
Syscon Board2  
Intel® Remove Management Module 22  
NIC Cable2  
Cable Management Bracket2  
Bypass Ethernet Ports3  
Rack Mount Kits4  
Some items above available as optional accessories as noted:  
1Refer to AC power cord accessory in section III  
2Refer to “Production Spares/Accessory List” in section IV  
3Refer to “Adding Bypass Ports” in section V  
4Refer to “Rack Mounts” in Appendix B  
Note: For these SKUs to be functional, one or more of the following is  
required: Power cord, CPU, Memory, Hard Drive, Operating System, Heatsinks  
5/18/2007  
v1.2  
13 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B. Rack Mounting Options for 1U and 2U Intel®  
Communications Rack Mount Servers  
Rack mounting kits for 2-post or 4-post, 19-inch or 23-inch racks are offered for  
this product. Please refer to the tables below for the correct options to suit your  
needs.  
All rack mount kits listed are suitable for 1U and 2U Intel® Communications Rack  
Mount Servers. Installation instructions are included in each kit.  
2-post Rack Mounting Kit Options  
Rack width  
Post depth  
Rack fastener hole spacing  
Applicable kits:  
19 inch 23 inch 3 inch 5 inch EIA-Wide EIA-Universal ETSI  
TMLCMOUNT21 ꢂ  
TMLPMOUNT41 ꢂ  
TMLPMOUNT51 ꢂ  
TMLPMOUNT52  
4-post Rack Mounting Kit Options  
Front-post to  
rear-post distance  
Rack fastener  
hole spacing  
Rack width  
Applicable kits:  
Min  
(inches)  
Max  
EIA-  
EIA-  
19 inch 23 inch  
ETSI  
(inches) Wide Universal  
TMLPMOUNT41 ꢂ  
TMLPMOUNT51 ꢂ  
TMLPMOUNT52  
20  
20  
24  
24  
20  
24  
TMLPSLIDE01ꢂ  
22.5  
28 or 34††  
The TMLPSLIDE01 kit contains server securing brackets. The rails and other  
options for mounting the server are available through other venders such as  
††34-inch span requires the optional Accuride "Long Bracket" kit.  
5/18/2007  
v1.2  
14 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TMLCMOUNT21  
The TMLCMOUNT21 kit mounts Intel® Communication Rack Mount Servers to a 2-  
post, central office type, 19” wide rack. This kit consists of simple L-shaped  
brackets; which fasten to the sides of the server and to the rack.  
TMLCMOUNT21  
5/18/2007  
v1.2  
15 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TMLPMOUNT41, TMLPMOUNT51 and TMLPMOUNT52  
TMLPMOUNT41/51/52 series mounts Intel® Communication Rack Mount Servers  
to 2-post or 4-post racks.  
TMLPMOUNT41 and TMLPMOUNT51 are used for mounting servers on 19” wide  
racks. These racks are considered standard EIA (universal hole spacing) racks.  
TMLPMOUNT52 is used for mounting servers on 23” wide racks. These racks could  
be standard EIA (universal or wide hole spacing) or ETSI (European) racks.  
TMLPMOUNT41/51/52 series are designed with a slide-in rail-type system.  
Although the mounts are designed as rails, they are not sliding rails. This means  
the servers can be slid into the racks for installation purpose, but the rails are  
not designed to support a mounted server during service.  
TMLPMOUNT4x/5x feature comparison  
Plastic  
strips2  
Not  
included  
Side  
TMLPMOUNT41  
TMLPMOUNT51  
TMLPMOUNT52  
No1  
Yes  
Yes  
EIA-Universal  
Interference  
access6  
Xylan  
EIA-Wide or EIA-  
Universal4  
Front  
access  
No  
Included5  
coating3  
Interferance  
Xylan  
EIA-Wide, EIA-  
Universal or ETSI  
Front  
access  
Included5  
N/A  
coating3  
Notes:  
1. Extra care must be exercised with TMLPMOUNT41 to securely hold the  
server with one's hands when sliding it out of the rack, else the server may  
fall to the ground as its being removed.  
2. Plastic strips on TMLPMOUNT41 have peeled off in some customer  
installations. Consequence: The parts are usable, but the server may have  
somewhat of a "scrape-in feel" rather than "slide in". Also, the rails will fit  
sloppier, so the side-located chassis securing screws may be difficult to  
align in 2-post installations. Replacement material is available from the  
plastic strip manufacturer.  
3. Xylan is a tough, low-friction coating similar to Teflon.  
5/18/2007  
v1.2  
16 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. EIA-Wide spacing doesn't have the interstitial hole that is present in EIA-  
Universal. TMLPMOUNT51 contains an adapter bracket to overcome this  
EIA-Wide issue.  
5. This component (2U Nut Bar) enables installation of a rail kit into a 1U  
rack slot when there is already equipment installed both above and below  
that open slot.  
6. The sides of the server must be accessible when using TMLPMOUNT41 in 2-  
post racks.  
5/18/2007  
v1.2  
17 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The diagrams above summarize the components and “slide-in rail-type” system  
of the TMLPMOUNT41. It can be adapted for a 2-post or 4-post installation.  
5/18/2007  
v1.2  
18 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The main difference between the TMLPMOUNT41 and TMLPMOUNT51/52 series is  
that the TMLPMOUNT41 series uses a screw to lock the server in place via the  
Universal Mounting Bracket, whilst the TMLPMOUNT51/52 series has an  
additional Slide Pull-Out Locking feature.  
The Universal Front Mounting Bracket on the TMLPMOUNT41  
The Slide Pull-Out Locking feature on the TMLPMOUNT51/52  
5/18/2007  
v1.2  
19 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TMLPSLIDE01  
The TMLPSLIDE01 is an accessory kit designed for use in conjunction with slide  
rails to produce a rack mounted serviceable server. The TMLPSLIDE01 kit  
contains two Universal Front Mounting Brackets that secure the server to the  
front of the rack. The sliding rails and optional mounting brackets required to  
mount the server must be purchased through the channel. For example, the  
Accuride 22-inch Model 305A-LR slide rails are designed to mount a server for  
“in-rack service.” This example would also use an Accuride mounting bracket kit  
and the TMLPSLIDE01.  
Universal Front Mounting Bracket with securing tab  
Note: Using slide rails may result in non-compliance with Seismic Zone 4  
requirements of NEBS-3 certification.  
Ordering Information  
Minimum Order  
PID  
Non-RoHS MM#  
RoHS MM#  
Quantity  
TMLCMOUNT21  
TMLPMOUNT41  
TMLPMOUNT51  
TMLPMOUNT52  
TMLPSLIDE01  
862501  
838890  
851760  
851745  
845583  
881904  
881907  
881934  
881935  
881915  
10  
10  
1
1
10  
5/18/2007  
v1.2  
20 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Customers should order RoHS items for shipments going to the European Union  
(EU).  
Although these mounts have been designed for industry standard racks, please  
consult with your Intel Field Application or Sales Engineer before selecting racks  
for these servers.  
Compatible rack mounting kits may also be obtained from 3rd party suppliers.  
5/18/2007  
v1.2  
21 of 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Intel Chipper 945G User Manual
Interphase Tech Fish Finder DC 1000 User Manual
Invacare Mobility Aid Color Collection User Manual
JL Audio Speaker Subwoofe User Manual
John Lewis Washer JLWM 1200 User Manual
JVC Camcorder GR AX275 User Manual
JVC Car Stereo System GET0091 001A User Manual
Kalorik Hot Beverage Maker JK 39825 User Manual
Kenwood Marine Radio TS 570DG User Manual
Kodak Scanner 9090DB User Manual