Intel® IP Network Server NSC2U
Configuration Guide System / Spares / Accessories List
March 2008
Rev 2.2
Reference guide to assist customers and the field in ordering the servers,
accessories and spares
~Subject to Change Without Notice~
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
I. INTRODUCTION ..............................................................................................4
3/28/2008
v 2.2
3 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
I. Introduction
Product Description:
The Intel® IP Network Server NSC2U system is the second generation product of 2U
Intel® IP Network Server products, having long product life and 20-inch depth
chassis. This server combines network port density and processor performance in a
compact 2U package. The NSC2U supports a number of processor speeds for the
Quad-Core Intel® Xeon® 5300 and 5400 series processors, coupling high performance
with power efficiency to provide improved performance-per-watt over previous-
generation rack-mount servers. The NSC2U also supports a number of processor
speeds for the Dual-Core Intel® Xeon® 5100 series processors.
The NSC2U is an excellent choice for network data applications with large I/O
requirements, while providing extended lifecycle support, DC power capabilities,
compact form factor, and the ruggedness found on carrier-grade servers. Ideal for
network security, it is an excellent choice for intrusion detection/intrusion
prevention, VPN/firewall, and unified threat management solutions. In addition, it
is a valuable platform for running Telco SoIP, including IMS, IPTV, Video on Demand
(VoD), SIP application servers, IP-PBX, and IP-PSTN Gateways. Other network
applications well-suited for this platform are enterprise application acceleration and
content caching.
More product information is available at the following websites:
NSC2U Product Overview:
NSC2U Product Support:
Purpose of this Document:
This document provides details on what parts are available for ordering of the Intel®
IP Network Server NSC2U production systems. This includes PID and MM#
information for System SKUs, Accessories & Spares, as well as other Intel parts that
are supported by the NSC2U product.
Supported third-party components are not covered by this document, and may be
found in the Tested Hardware and Operating System List (THOL) for this product.
3/28/2008
v 2.2
4 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
II. Production System SKUs
The NSC2U Production System SKUs that can be ordered are listed below:
Product
Identification Code
Min. Order
Description
MM#
Qty.
Intel® IP Network Server NSC2U,
Base Model 0 with AC Power Supply
NSCA0201W
NSCD0201W
889358
1
Intel® IP Network Server NSC2U,
Base Model 0 with DC Power Supply
889357
1
See the NSC2U Base Model 0 Configuration table further down in this section for a
list of components included in each base model 0 SKU.
Production SKUs are offered as either an AC or DC version. The Product
Identification code, or PID, of all SKUs contains either the letter “A” for AC or “D”
for DC as the 4th digit of the PID.
Both Production SKUs are base model 0 SKUs, (no processor, heatsink, memory, hard
drive, power cord, operating system, or plug-in adapters are provided). Those
components must be ordered separately as Accessories from Intel or from third
party vendors listed in the Tested Hardware and Operating System List (THOL).
Power Cords are not included with the Mod 0 system. For AC Power cords, order the
NA – North American power cord below. This power cable is RoHS-compliant.
PID
MM#
Comments
This AC power cable can be ordered by North
America (NA) customers. International customers
should procure their specific power cords directly.
PWRCABLEUS 816324
Note: Ensure that customers have the appropriate technical support and contact
before placing their first order.
3/28/2008
v 2.2
5 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
NSC2U Base Model 0 Configuration:
All Production SKUs are base model 0 SKUs (no processor, heatsink, memory, hard drive,
power cord, operating system, or plug-in adapters are provided). Those components must
be ordered separately as Accessories from Intel or from third party vendors listed in the
Tested Hardware and Operating System List (THOL).
The table below lists which components are included in the base model 0 SKUs and which
ones must be ordered separately or as optional accessories.
AC Mod 0
Configuration Configuration
DC Mod 0
Component Description
AC power supply (600 W)
DC power supply (600 W)
1 included
-
-
1 included
Filler Panel in 2nd power supply bay
Chassis (bezel, sheet metal, top cover, PCI carrier)
Server Board T5000PAL
1 included
1 included
1 included
Bezel (gray)
1 included
PCI Riser FH-FL (two PCI-Express and one PCI-X slots)
PCI Riser LP (two PCI-Express slots)
FB-DIMM slots (memory not included)
Trays for hot-swap 2.5” SAS Hard Disk Drives
Filler Panel in optical device bay
Rear Panel GbE NIC (Cu) ports (via Server Board)
Server Deployment Toolkit (CD)
Quick Start Guide
1 included
1 included
8 included
6 included
1 included
2 included
1 included
1 included
Power Cable
SW RAID 0/1/10
Purchase separately1
Included
HW RAID 5
Optional Accessories2
Optional Accessory2
Optional Accessory2
Optional Accessory2
Optional Accessories2
Optional Accessory2
Optional Accessory2
Optional Accessory4
Purchase separately5
Accessory or purchase separately
Purchase separately5
Purchase separately5
Purchase separately5
Intel® Z-U130 Value Solid State Drive
Mounting kit for Intel® Z-U130 Value Solid State Drive
Remote Management Module 2
PCI-X FH-FL Riser (3 PCI-X slots)
Ethernet I/O Module (dual Gigabit rear ports)
SAS I/O Expansion Module (x4 external rear port)
Rack Mount Kits
Processor (refer to “Details on Ordering Processors”)
Heatsink
Memory
Hard Disk Drive
Optical Drive
Accessories for NIC-in-Front Capability3
Quad Port Bypass Adapter (Copper)
Quad Port Bypass Adapter (Fiber)
Optional Accessory3
Optional Accessory3
Optional Accessory3
Optional Accessory3
Quad NIC-in-Front Mounting Kit (Copper)
Quad NIC-in-Front Mounting Kit (Fiber)
1Refer to AC power cord accessory in this section
2Refer to “Production Spares/Accessories List” in section III
3Refer to “Quad Port Bypass NIC Capability” in section IV
4Refer to “Rack Mounting Options” in the Appendix
5Should be purchased separately (parts not listed in this document)
3/28/2008
v 2.2
6 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes on the NSC2U Model 0 Configuration and Options:
PCI Risers
o The base configuration comes standard with two PCI Risers supporting up
to five PCI slots. These include:
¾ One low-profile riser supporting two PCI-Express (PCIe) slots
¾ One full-height, full-length riser supporting three slots: two PCIe
x4 and one PCI-X.
o Additional full-height, full-length risers (below) are supported and
available as accessories (refer to “Production Spares/Accessories List” in
section III).
¾ PCI-X (active): three independent PCI-X, each with maximum 133
MHz
¾ PCI-X (passive): two PCI-X with maximum 100 MHz and one PCI-X
(66 MHz) all on a shared PCI bus
HW RAID
o While SW RAID 0/1/10 is supported on the base configuration, HW RAID 5
support can be enabled via a set of optional accessories (refer to
“Production Spares/Accessories List” in section III).
o Components required are NSCRAID01W (NSC2U RAID5 Kit – includes the I-
Button (license), battery cable) and the AXXMINIDIMM (128 MB Mini DIMM
registered DDR-2 for RAID cache.)
o An additional option is the AXXRSBBU3 (Intel® RAID Smart Battery Backup
module provides up to 72 hours of cache memory retention when used
with AXXMINIDIMM). The cable to connect the battery is included in the
NSCRAID01W kit.
Intel® Z-U130 Value Solid State Drive
o Support for the Intel® Z-U130 Value Solid State Drive is available via a
selection of optional accessories (refer to “Production Spares/Accessories
List” in section III).
o Components required are an Intel® Z-U130 Value Solid State (select
desired capacity) as well as a mounting kit (TMWVSSDRIVE01W) to mount
it inside the chassis.
o Solid state drives are available in several sizes, enabling an array of
product customization options. These drives securely mount inside the
chassis offering
¾ Storage: independent of traditional disk drives
¾ Boot OS from solid state drive; store data on hard drive
¾ Store backup image of boot drive
¾ Add a server partition to the server
¾ Any other customer design options
3/28/2008
v 2.2
7 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
IO Option Modules
o These modules, available as optional accessories, attach to the system
board via a proprietary connector, and provide additional IO through the
rear bulkhead.
¾ The AXXGBIOMO option module provides two Gigabit Ethernet NICs.
¾ The AXXSASIOMOD option module provides one x4 external SAS
port.
o For ordering details, refer to “Production Spares/Accessories List” in
section III.
Quad Port Bypass NIC Capability
o The NSC2U is capable of supporting up to eight ports of front or rear-
accessible Gigabit Ethernet (either Copper or Fiber) using Quad NIC
adapters designed by Intel. Optional accessories are available to enable
these features. For more information and ordering details, refer to
“Quad Port Bypass NIC Capability” in section IV.
For more detailed information on the NSC2U, refer to the web links below.
Additional Product Details
Check the following web site for more information on the NSC2U:
Support.Intel.Com Users
Product information including specifications, compatibility, user’s guides, drivers,
firmware, and software associated with the Intel® Network Server NSC2U is
available from Intel Customer Support.
Intel® Network Server NSC2U Support Web Site
If you can not access the documents using the links provided, please contact your
FAE/FSE for assistance.
3/28/2008
v 2.2
8 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Details on Ordering Processors:
The NSC2U is designed for the Quad-Core Intel® Xeon® 5400 and 5300 processor series,
and also supports selected SKUs from the Dual-Core Intel® Xeon® 5100 series processors.
Ordering details for the supported processors for the NSC2U are listed below. These
include the choice of either Tray (for OEMs) or Boxed (Retail channel) processors.
Intel® Xeon® Processors Supported by NSC2U:
Processor
Number
E5440
Long
Life
Yes
Boxed Processor
Tray Processor
Product Code
Cores
Speed
TDP
FSB
Product Code
MM#
MM#
Quad
2.83 GHz
80W
1333 MHz
BX80574E5440P 894824
EU80574KJ073N
893484
L5410
E5345
E5335
E5320
E5310
5160
Yes
Yes
Yes
No
Quad
Quad
Quad
Quad
Quad
Dual
Dual
Dual
Dual
2.33 GHz
2.33 GHz
2.00 GHz
1.86 GHz
1.60 GHz
3.00 GHz
2.33 GHz
2.00 GHz
1.86 GHz
50W
80W
80W
80W
80W
80W
65W
65W
40W
1333 MHz
1333 MHz
1333 MHz
1066 MHz
1066 MHz
1333 MHz
1333 MHz
1333 MHz
1066 MHz
BX80574L5410P 894835
EU80574JJ053N
893491
891115
891116
BX80563E5345P 892334 HH80563QJ0538M
BX80563E5335P 892335 HH80563QJ0418M
BX80563E5320P 892337 HH80563QH0368M 891118
BX80563E5310P 892333 HH80563QH0258M 891121
No
No
BX805565160P
BX805565140P
BX805565130P
N/A
892200
892169
884531
N/A
HH80556KJ0804M
HH80556KJ0534M
HH80556KJ0414M
HH80556JH0364M
891706
891730
891731
891704
5140
Yes
Yes
Yes
5130
LV 5128
Notes:
Although all of the above processors have been certified on the NSC2U, Intel recommends the
use of the following processors from Intel’s Embedded Communications and Processor Division
(ECG) for long availability and support:
o E5440 (Quad-Core, 2.83 GHz, 1333 MHz FSB, TDP=80 W)
o L5410 (Quad-Core, 2.33 GHz, 1333 MHz FSB, TDP=50W)
o E5345 (Quad-Core, 2.33 GHz, 1333 MHz FSB, TDP=80 W)
o E5335 (Quad-Core, 2.00 GHz, 1333 MHz FSB, TDP=80 W)
o 5140
o 5130
(Dual-Core, 2.33 GHz, 1333MHz FSB, TDP=65W)
(Dual-Core, 2.00 GHz, 1333MHz FSB, TDP=65W)
o LV 5128 (Dual-Core, 1.86 GHz, 1066MHz FSB, TDP=40W)
Heatsinks
o This product requires Passive heatsinks. The boxed processors listed above include a
Passive Heatsink Kit, made of aluminum. Do not use Active Fan Heatsinks, which are
provided in some Retail Boxed Processors.
o For Tray processors, you will need to procure a Heatsink for each processor (see
NSCSNKCLP01 in the Spares/Accessories list below). This is a copper heatsink. There
are no clips needed for this heatsink, since the heatsink includes captive screws.
o If ordering other Boxed Processors (not listed here), do not use the fansink, which
might be included.
Note that processor product codes can change, and that the above is a snapshot current as of
3/28/2008. Please consult with your Intel representative for SSpec or MM# which might be
needed for ordering the processor. Any differences in functionality are reported in the
3/28/2008
v 2.2
9 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
III. Production Spares/Accessories List
Below are the Spare parts and Accessories that can be ordered with the NSC2U system.
Any of these parts can be ordered as spares for part replacement purposes or as additional
customer inventory. Some of the parts below are not included in the NSC2U system base
model and can be ordered as accessories for purposes of upgrading the base model to
include additional features.
For a listing of additional compatible accessories, such as Optical Devices for use with the
CD-ROM carrier, please refer to the Tested Hardware and Operating System List (THOL).
Included in
Base Model MM#
(Y/N)
Min.
Order
Qty
PID Order Code
Description
Contents
Y (one in AC
880110
SKU)
AC power supply
TIGI2U AC Power Supply
TIGI2U DC Power Supply
NSC2U Processor Heatsink
1
1
1
TLIACPSU003
TLIDCPSU003
NSCSNKCLP01
DC power supply,
input power connector
Y (one in DC
880116
SKU)
Heat sink (copper)
N
891200
12
Bezel, packaged in
cartons of 12
Y
(order in
multiples
of 12)
NSC2U Bezel (Unpainted), 12-pack
NSCBEZEL01W
889820
(one bezel)
Unpainted blank
48
2 blank panels
installed in base
model
NSC2U Blank Escutcheons (unpainted)
– 48 pack
escutcheon panel
(filler panel if front-
NICs are not present)
(order in
multiples
of 48)
NSCESCBLNK01W
HW RAID
897011
890202
I-Button (license),
battery cable (battery
or mini-DIMM not
included)
NSC2U RAID5 Kit
N
N
1
5
NSCRAID01W
Intel® RAID Smart Battery Backup
module: for use with Intel® Integrated
Server RAID (requires NSCRAID01W
plus mini DIMM), provides up to 72
hours of cache memory retention when
used with AXXMINIDIMM.
(order in
multiples
of 5)
Battery backup kit
Mini-DIMM
AXXRSBBU3
883471
881258
5
128 MB Mini DIMM registered DDR-2
for RAID cache. Note: enabling RAID
capability also requires Intel RAID
Activation Key– NSCRAID01W
(order in
multiples
of 5)
N
AXXMINIDIMM
Remote Management
Intel® Remote Management Module 2
(RMM2) - Single Pack
RMM2 with GCM
(single-pack)
N
N
1
AXXRMM2
894383
894385
1
(specify
‘1’ for
Intel Remote Management Module 2
(RMM2) – 10-Pack
RMM2 with GCM (10-
pack)
AXXRMM2BULK
each 10-
pack)
3/28/2008
v 2.2
10 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Production Spares/Accessories List (continued)
Included in
Min.
Order
Qty
MM#
PID Order Code
Description
Contents
Base Model
(Y/N)
PCI Risers and I/O Options
SR2400 (2U) Full Height PCI-Express
riser (two PCI-Express slots, one PCI-
X slot)
Riser
Riser
Y
1
ASR2500FHR
880515
SR2500 (2U) Full Height PCI-X
"active" high performance riser card
(three PCI-X slots)
N
N
1
1
ADRACTRIS
ADRPCIXRIS
856546
863135
SR2500 (2U) Full Height PCI-X
“passive” riser card (three PCI-X slots)
Riser
Riser
Two-slot Low Profile PCI-Express riser
Dual Gigabit Ethernet I/O Module
Y
N
N
1
1
1
FSR2500LPR
880516
880518
880517
Dual Gigabit rear
ports
AXXGBIOMOD
Four-port external SAS I/O Expansion
Module
x4 external rear port
AXXSASIOMOD
Solid State Drives
Mounting kit for Intel® Z-U130
Value Solid State Drive
Interposer board,
cable, mounting
screws (flash drive
not included)
N
1
TMWVSSDRIVE01W
893165
Requires Intel® Z-U130 Value Solid State
Drive (purchased separately).
Intel® Z-U130 Value Solid State Drive
- 1 GB, Low Profile Connector
1 GB Module – Low
Profile Connector
N
N
N
10
10
10
SSDUSMS0001GL10
SSDUSMS0002GL10
SSDUSMS0004GL10
890945
890943
890941
Requires TMWVSSDRIVE01W
Intel® Z-U130 Value Solid State Drive
– 2 GB, Low Profile Connector
2 GB Module – Low
Profile Connector
Requires TMWVSSDRIVE01W
Intel® Z-U130 Value Solid State Drive
- 4 GB, Low Profile Connector
4 GB Module – Low
Profile Connector
Requires TMWVSSDRIVE01W
Spares
Power distribution
board, with integrated
wire harness
NSC2U Power Distribution Board
Y
Y
1
1
NSCPWRDISBDW
889805
889812
NSC2U Front Panel IO Board with LED
pipe
Board, set of front
panel light pipes
NSCFPIOBDLPW
Board
NSC2U T5000PAL Server board
NSC2U SAS Backplane
NSC2U Bridge board
Y
Y
Y
1
1
1
NSCSASBSBDW
NSCSASBKPLNW
NSCBRIDGEBDW
889828
889829
889852
Backplane
Board, insulator
3/28/2008
v 2.2
11 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Production Spares/Accessories List (continued)
Included in
Min.
Order
Qty
MM#
PID Order Code
Description
Contents
Base Model
(Y/N)
Spares
Flex cable (SAS
interface, front panel
signals), front panel
power cable, serial
port cable, CD-ROM
cable, alarm cable,
TAM module cable
NSC2U System Interconnect Cable Kit
Y
1
NSCCBLMSCW
889819
80 mm CPU fans (2),
40 mm PCI fans (2),
plastic fasteners (8)
NSC2U Fan Assembly (set of four)
NSC2U DVD Drive Engagement Tab
Y
Y
1
1
NSCFANSETW
889822
889845
Blue plastic
engagement bracket
and black plastic
locking clip, screws
NSCDVDENGTABW
10
Carrier, black plastic
filler, screws (4)
(order in
multiples
of 10)
TIGW1U SAS HDD carrier
Y
FXX25HDDCAR
881681
Note: There are also accessories/spares specific to Quad Port Bypass NIC capability. For
these items, please refer to Section IV “Quad Port Bypass NIC Capability”.
3/28/2008
v 2.2
12 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
IV. Quad Port Bypass NIC Capability
This section is intended for customers that plan to use the Quad Port NIC with Bypass
capability on the NSC2U. It describes what parts must be ordered to enable this capability.
The NSC2U is capable of supporting:
• Up to eight ports of front-accessible Gigabit Ethernet (either Copper or Fiber) using
Quad NIC adapters designed by Intel. The front-accessible NIC configuration also
requires the purchase of an internal cabling/mounting kit including an escutcheon for
securing the front ports.
• Up to eight ports of rear-accessible Gigabit Ethernet (Copper or Fiber) using Quad NIC
adapters also designed by Intel.
The Quad Bypass adapters and the cabling/mounting kits come in packages of five units
each. These kits include five of the NIC cables designed for the NSC2U system, as well as
the escutcheons, cable management bracket, and associated screws to complete the
installation of the Bypass adapter in the system. Also there are bulk pack (48 count)
escutcheon kits (copper, fiber, and filler panel) available to streamline the customization
and painting process of the system.
Below are the Accessories that may be ordered to enable the Quad Port Bypass NIC
capability on the NSC2U system. Note: For a list of other tested Network Interface Cards
(NICs) refer to the Tested Hardware and Operating System List (THOL).
Included in
Base Model MM#
(Y/N)
Min.
Order
Qty
PID
Order Code
Description
Contents
Copper NIC
Quad-port design,
based on two Intel®
82571GB dual-port
PCI Express*
Intel® PRO/1000 PT Quad Port
Bypass Adapter (Copper)
– 5 Pack
EXPI9014PTBLK
(Bypass rear access)
N
N
5
876697
876699
GbE controllers
Quad-port design,
based on two Intel®
82571GB dual-port
PCI Express*
Intel® PRO/1000 PT Quad Port
Bypass Adapter (Copper, NIC-in-
Front) – 5 Pack
EXPI9024PTBLK
(Bypass NIC-in-front)
5
5
GbE controllers
Quad NIC-in-front
cable assembly,
escutcheon and
screws for copper
ports, cable
NSC2U Quad NIC-in-Front
Mounting Kit (Copper) – 5 Pack
N
N
NSCCBLFNICW
890325
(order in
multiples
of 5)
management bracket
and screw
Unpainted
48
escutcheons for use
with NSCCBLFNICW
Intended for prep
(painting) purposes.
Note: Five
escutcheons are
included in
NSC2U Escutcheons for Copper
ports (unpainted) – 48 Pack
(order in
multiples
of 48)
NSCESCCPR01W
898020
NSCCBLFNICW
3/28/2008
v 2.2
13 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Included in
Base Model MM#
(Y/N)
Min.
Order
Qty
PID
Order Code
Description
Contents
Fiber NIC
Quad-port design,
based on two Intel®
82571GB dual-port
PCI Express*
EXPI9014PFBLK
(Bypass rear access)
Intel® PRO/1000 PF Quad Port
Bypass Adapter (Fiber) – 5 Pack
N
N
5
876696
876694
GbE controllers
Quad-port design,
based on two Intel®
82571GB dual-port
PCI Express*
Intel® PRO/1000 PF Quad Port
Bypass Adapter (Fiber, NIC-in-
Front) – 5 Pack
EXPI9024PFBLK
(Bypass NIC-in-front)
5
5
GbE controllers
Quad NIC-in-front
escutcheon, and LED
cable for fiber ports,
cable management
bracket and screw
NSC2U Quad NIC-in-Front
Mounting Kit (Fiber) – 5 Pack
N
NSCCBLFNICFBRW
NSCESCFBR01W
897002
898021
(order in
multiples
of 5)
Unpainted
escutcheons for use
with
NSCCBLFNICFBRW
Intended for prep
(painting) purposes.
N
48
Note: Five
escutcheons are
included in
NSCCBLFNICFBRW
NSC2U Escutcheons for Fiber
ports (unpainted) – 48 Pack
(order in
multiples
of 48)
Miscellaneous
48
Unpainted blank
2 blank panels
installed in base
model
NSC2U Escutcheons filler panel
(unpainted) – 48 pack
escutcheon panel
(filler panel if front-
NICs are not present)
(order in
multiples
of 48)
NSCESCBLNK01W
897011
Overview of Intel® PRO/1000 Quad Port Bypass Server Adapters:
The Intel® PRO/1000 PT and PF Quad Port Bypass Server Adapters provide in-line server
appliances, such as Intrusion Protection Servers (IPSes), with high-performance, low-latency,
in-line connectivity, and a bypass mode to ensure business continuity. These adapters also use
the PCI Express* serial bus for greater throughput, and they support Intel® I/O Acceleration
Technology (Intel® I/OAT) for further performance enhancement, including the reduced
overhead so important to IPS applications.
The Intel® PRO/1000 PT and PF Quad Port Bypass Server Adapters are intended for use by
equipment manufacturer hardware designers in application-specific in-line server appliances,
where a bypass mode is desirable. Given that equipment manufacturers typically write specific
software applications for their in-line platforms, Intel only provides open source reference
drivers for these adapters. Interested hardware designers may contact their local Intel
representative for additional product or purchase information.
More information on Intel® PRO/1000 Quad Port Bypass Server Adapters is available at:
3/28/2008
v 2.2
14 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A. Rack Mounting Options for 1U and 2U
Intel® Communications Rack Mount Servers
Rack mounting kits for 2-post or 4-post, 19-inch or 23-inch racks are offered for this
product. Please refer to the tables below for the correct options to suit your needs.
All rack mount kits listed are suitable for 1U and 2U Intel® Communications Rack Mount
Servers. Installation instructions are included in each kit.
2-post Rack Mounting Kit Options
Rack width
Post depth
Rack fastener hole spacing
Applicable kits:
19 inch
23 inch
3 inch
5 inch
EIA-Wide
EIA-Universal ETSI
TMLCMOUNT21
TMLPMOUNT41
TMLPMOUNT51
TMLPMOUNT52
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
4-post Rack Mounting Kit Options
Front-post to
Rack fastener
hole spacing
Rack width
rear-post distance
Applicable kits:
Min
(inches)
Max
(inches)
EIA-
Wide
EIA-
Universal
19 inch
23 inch
ETSI
TMLPMOUNT41
TMLPMOUNT51
TMLPMOUNT52
TMLPSLIDE01†
√
√
20
20
24
24
√
√
√
√
√
√
√
20
24
√
√
22.5
28 or 34††
†The TMLPSLIDE01 kit contains server securing brackets. The rails and other options for
mounting the server are available through other venders such as Accuride
††34-inch span requires the optional Accuride "Long Bracket" kit.
3/28/2008
v 2.2
15 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
TMLCMOUNT21
The TMLCMOUNT21 kit mounts Intel® Communication Rack Mount Servers to a 2-post,
central office type, 19-inch wide rack. This kit consists of L-shaped brackets that fasten to
the sides of the server and to the rack.
TMLCMOUNT21
3/28/2008
v 2.2
16 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
TMLPMOUNT41, TMLPMOUNT51 and TMLPMOUNT52
TMLPMOUNT41/51/52 series mounts Intel® Communication Rack Mount Servers to 2-
post or 4-post racks.
TMLPMOUNT41 and TMLPMOUNT51 are used for mounting servers on 19-inch wide racks.
These racks are considered standard EIA (universal hole spacing) racks.
TMLPMOUNT52 is used for mounting servers on 23-inch wide racks. These racks could be
standard EIA (universal or wide hole spacing) or ETSI (European) racks.
TMLPMOUNT41/51/52 series are designed with a slide-in rail-type system. Although the
mounts are designed as rails, they are not sliding rails. This means the servers can be slid
into the racks for installation purpose, but the rails are not designed to support a mounted
server during service.
TMLPMOUNT4x/5x Feature Comparison
Plastic
strips2
Not
included
Side
TMLPMOUNT41
TMLPMOUNT51
TMLPMOUNT52
No1
Yes
Yes
EIA-Universal
Interference
No Interference
N/A
access6
Xylan
EIA-Wide or EIA-
Universal4
Front
access
Included5
Included5
coating3
Xylan
EIA-Wide, EIA-
Universal or ETSI
Front
access
coating3
Notes:
1. Extra care must be exercised with TMLPMOUNT41 to securely hold the server with one's hands
when sliding it out of the rack; otherwise, the server could fall to the ground as it is being
removed.
2. Plastic strips on TMLPMOUNT41 have peeled off in some customer installations. The result of
this is that the parts are usable, but the server could have somewhat of a "scrape-in feel" rather
than "slide in". Also, the rails will fit sloppier, so the side-located chassis securing screws could
be difficult to align in 2-post installations. Replacement material is available from the plastic
strip manufacturer.
3. Xylan is a tough, low-friction coating similar to Teflon.
4. EIA-Wide spacing doesn't have the interstitial hole that is present in EIA-Universal.
TMLPMOUNT51 contains an adapter bracket to overcome this EIA-Wide issue.
5. This component (2U Nut Bar) enables installation of a rail kit into a 1U rack slot when there is
already equipment installed both above and below that open slot.
6. The sides of the server must be accessible when using TMLPMOUNT41 in 2-post racks.
3/28/2008
v 2.2
17 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
The diagrams above summarize the components and “slide-in rail-type” system of the
TMLPMOUNT41. It can be adapted for a 2-post or 4-post installation.
3/28/2008
v 2.2
18 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
The main difference between the TMLPMOUNT41 and TMLPMOUNT51/52 series is that the
TMLPMOUNT41 series uses a screw to lock the server in place using the Universal
Mounting Bracket, whilst the TMLPMOUNT51/52 series has an additional Slide Pull-Out
Locking feature.
Universal Front Mounting Bracket on the TMLPMOUNT41
Slide Pull-Out Locking feature on the TMLPMOUNT51/52
3/28/2008
v 2.2
19 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
TMLPSLIDE01
The TMLPSLIDE01 is an accessory kit designed for use in conjunction with slide rails to
produce a rack mounted serviceable server. The TMLPSLIDE01 kit contains two Universal
Front Mounting Brackets that secure the server to the front of the rack. The sliding rails
and optional mounting brackets required to mount the server must be purchased through
the channel. For example, the Accuride 22-inch Model 305A-LR slide rails are designed to
mount a server for “in-rack service.” This example would also use an Accuride mounting
bracket kit and the TMLPSLIDE01.
Universal Front Mounting Bracket with securing tab
Note: Using slide rails could result in non-compliance with Seismic Zone 4 requirements of
NEBS-3 certification.
Ordering Information
Minimum Order
PID
Non-RoHS MM#
RoHS MM#
Quantity
TMLCMOUNT21
TMLPMOUNT41
TMLPMOUNT51
TMLPMOUNT52
TMLPSLIDE01
862501
838890
851760
851745
845583
881904
881907
881934
881935
881915
10
10
1
1
10
Customers should order RoHS items for shipments going to the European Union (EU).
Although these mounts have been designed for industry standard racks, please consult
with your Intel Field Application or Sales Engineer before selecting racks for these servers.
Compatible rack mounting kits can also be obtained from 3rd party suppliers.
3/28/2008
v 2.2
20 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
|