Ingersoll Rand Water Pump 66266 XXX B User Manual

OPERATOR’S MANUAL  
66266-XXX-B  
1-8-99  
RELEASED:  
REVISED:  
(REV. 04)  
INCLUDING: SERVICE KITS, TROUBLESHOOTING, PARTS LIST,  
DISASSEMBLY & REASSEMBLY.  
10-18-10  
CHOP-CHECK STYLE  
LOWER PUMP ENDS  
Also covers 637074-X43-B service kits  
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,  
OPERATING OR SERVICING THIS EQUIPMENT.  
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.  
SERVICE KITS  
LOWER PUMP END DESCRIPTION CHART  
Use only genuine ARO® replacement parts to assure com-  
patible pressure rating and longest service life.  
637074-X43-B for general repair of 66266-XXX-B lower  
pump ends.  
66266 - X 4 3 - B  
y
y
Packing Material  
3 - Glass filled PTFE (upper and lower)  
C - UHMW-PE (upper and lower)  
G - UHMW-PE / Leather staggered (upper and lower)  
P - UHMW-PE / Glass filled PTFE staggered (upper)  
- UHMW-PE (lower)  
GENERAL DESCRIPTION  
R - Glass filled PTFE / UHMW-PE staggered (upper)  
- Glass filled PTFE (lower)  
WARNING DO NOT EXCEED MAXIMUM OPERATING  
PRESSURE AS INDICATED ON PUMP MODEL PLATE.  
WARNING REFER TO GENERAL INFORMATION SHEET  
FOR ADDITIONAL SAFETY PRECAUTIONS AND IMPOR-  
TANT INFORMATION.  
Spring Arrangement  
4 - Multiple wave spring  
This manual only covers the lower pump section. It is one  
of four documents which support an ARO pump. Replace-  
ment copies of these forms are available upon request.  
y
y
Plunger Type  
3 - Hardened stainless steel with hard chrome plating  
Service Kit Selection  
66266 - X 4 3 - B  
637074 - X 4 3 - B  
Packing  
650XXX-X Pump Model Operator’s Manual.  
General Information for Air Operated or Hydraulically  
Operated Pumps.  
Lower Pump End Operator’s Manual.  
Air or Hydraulic Motor Operator’s Manual.  
Example: Lower Pump End # 66266-C43-B  
Service Kit # 637074-C43-B  
Plunger  
:
TROUBLE SHOOTING  
The chop-check design provides for easy priming of the  
lower foot valve. The double acting feature is standard  
in all ARO industrial pumps. Material is delivered to the  
pump discharge outlet on both the up and down stroke.  
No material at outlet (pump continually cycles).  
Check material supply. Disconnect or shut off the air sup-  
ply and replenish the material, reconnect.  
y
MAINTENANCE  
Material on one stroke only (fast downstroke).  
The (21) check may not be seating in the (22) seat (see  
lower pump disassembly). Remove the check from the  
seat, clean and inspect the check and seat area. If the  
check or seat is damaged, replace.  
y
The air / hydraulic motor is completely separate from the  
lower pump end. This helps to keep the motor from being  
contaminated by the material being pumped. Periodically,  
flush entire pump system with a solvent that is compatible  
with the material being pumped.  
Keep solvent cup filled with this compatible solvent. This will  
keep material from drying on the piston rod, which would  
drag thru the packings, ruin them and eventually scour the  
piston rod.  
Provide a clean work surface to protect sensitive internal  
moving parts from contamination from dirt and foreign mat-  
ter during disassembly and reassembly.  
Before reassembling, lubricate parts as required. When as-  
sembling “O” rings, or parts adjacent to “O” rings, exercise  
care to prevent damage to “O” rings and “O” ring groove sur-  
face.  
Material on one stroke only (fast upstroke).  
The (34) valve rod may not be seating in the (28) seat (see  
lower pump disassembly). Remove the valve rod from the  
seat, clean and inspect the valve rod and seat area. If the  
valve rod or seat is damaged, replace. Check for worn or  
damaged packings. Replace the packings as necessary.  
y
Material leakage out of the solvent cup or material ap-  
pears on the pump plunger rod.  
Relieve the pressure in the pump and tighten the solvent  
cup until leakage discontinues. If this procedure does not  
aid in stopping the leakage problem, the upper packings  
may be worn (see lower pump disassembly). Replace the  
packings as necessary.  
y
INGERSOLL RAND COMPANY LTD  
209 NORTH MAIN STREET – BRYAN, OHIO 43506  
(800) 495-0276 FAX (800) 892-6276  
CCN 99768657  
© 2010  
y
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST / 66266-XXX-B  
UPPER PACKING  
51  
51  
52  
52  
1  
51  
53  
43  
115  
1 - 11-1/2 N.P.T.F. - 1  
6
7
26  
9
10  
MIDDLE PACKING  
28  
11  
7
47  
57  
36  
24  
25  
21  
23  
22  
15  
30  
55  
55  
56  
34  
37  
65  
23  
56  
54  
LUBRICATION / SEALANTS  
c
d
Keep solvent cup filled with a lubricant such as  
Wet Sol "Plus" or equivalent.  
Apply Loctite® 242® to threads when assembling.  
31  
32  
33  
Figure 1  
66266-XXX-B (en)  
Page 3 of 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(34) valve rod (beveled end first).  
8. Thread the (34) valve rod to the (26) plunger rod and  
tighten, using the wrench flats provided.  
9. Assemble one (23) “Oring, the (22) seat (large o.d. cham-  
fer facing down) and the other (23) “O” ring into the (15)  
pressure chamber body.  
10. Assemble the (26) plunger rod and components into the  
(15) pressure chamber body with the (30) primer rod go-  
ing in first. Slide the (25) check stop into place in the (25)  
pressure chamber body.  
11. Place the (7) gasket in the (25) check stop.  
12. Lubricate the middle packing assembly and the inside of  
the (9) suction tube and carefully slide the suction tube  
over the (26) plunger rod and middle packing assembly  
and into the (25) check stop.  
13. Install the three (10) tie rods.  
14. Place the (7) gasket on the end of the (9) suction tube.  
NOTE: Apply a small amount of grease on the gasket to  
help keep it in place.  
15. Assemble the (6) pump body over the (26) plunger rod  
and onto the (10) tie rods. Seat the (9) suction tube into  
the (6) pump body.  
16. Assemble the (43) wave spring, (53) male packing  
washer, (51 and 52) “V” packings and (115) backup onto  
the (26) plunger rod and into the (6) pump body (refer to  
page 3).  
17. Install the (1) solvent cup assembly and hand tighten.  
18. Push the (26) plunger rod down to expose the (30)  
primer rod at the bottom of the pump. Assemble the (31)  
primer plate and the (32) primer button (beveled edge  
away from the pump) onto the (30) primer rod, securing  
with the (33) lock nut.  
19. Push up on the (30) primer rod until the primer rod is  
inside the (15) pressure chamber body, then tighten the  
(1) solvent cup assembly.  
PN 97999-829  
Page 4 of 4  
66266-XXX-B (en)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Invacare Respiratory Product IRC5LXO2 IRC5LX User Manual
JVC DVD Player XV NA7SL User Manual
JVC Speaker System UX V9RMD User Manual
Keating Of Chicago Fryer 20 TS Gas User Manual
Kenmore Washer 11026832692 User Manual
Kenwood CD Player 467FM User Manual
Kenwood Stereo Receiver C V751 User Manual
Kettler Rowing Machine ST2520 64 User Manual
Keys Fitness Home Gym 835R User Manual
KitchenAid Ice Maker W10515677C User Manual