Ingersoll Rand Water Pump 650632 X C User Manual

OPERATOR’S MANUAL  
650632--X--C  
SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, TROUBLESHOOTING  
INCLUDE MANUALS: 6695X--X LOWER PUMP END (PN 97999--002) &  
RELEASED: 11--15--96  
REVISED:  
6--4--10  
S--632 GENERAL INFORMATION MANUAL (PN 97999--624)  
(REV. 02)  
650632--X43--C  
6” AIR MOTOR  
4:1 RATIO  
FOUR BALL PUMP SERIES  
6” STROKE  
CARBON STEEL, ELECTROLESS NICKEL PLATED  
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,  
OPERATING OR SERVICING THIS EQUIPMENT.  
SERVICE KITS  
PUMP DATA  
Use only genuine AROR replacement parts to assure compatible  
pressure rating and longest service life.  
MODEL 650632-X43-C  
61355 for repair of Air Motor section.  
Service Note: The Air Motor Service/Parts Manual is not shipped  
with the pump but it is included with each Service Kit. If this Service/  
PartsInformationisneeded,requesttheAirMotorOperator’sManu-  
al from ARO. (Manual 6564X--X, PN 97999--174).  
Air Inlet  
1/2--14 NPTF--1(f)  
(Not Shown)  
637230- X43 for repair of Lower Pump section.  
Refer to the chart on page 2 for description of --X43 options.  
Air Motor  
65665--B  
SPECIFICATIONS  
(See Manual 6564X--X)  
38-5/8  
(981 mm)  
Model Series (Refer to option chart) . . 650632--X43--C  
Type . . . . . . . . . . . . . . . . . . . . Air Operated, Four Ball  
Ratio . . . . . . . . . . . . . . . . . . . . 4:1  
Air Motor . . . . . . . . . . . . . . . . . 65665--B  
Motor Repair Kit . . . . . . . . . . 61355  
Motor Diameter . . . . . . . . . . . 6” (15.2 cm)  
Stroke . . . . . . . . . . . . . . . . . . 6’’  
Air Inlet . . . . . . . . . . . . . . . . . 1/2’’ -- 14 NPTF--1(f)  
Air Exhaust . . . . . . . . . . . . . . 1--1/4’’, 11--1/2 NPTF--1(f)  
Lower Pump End Series . . . . . 66953--X43  
Lower Pump Repair Kit . . . . . 637230--X43  
Material Outlet . . . . . . . . . . . 3/4” NPTF--1(f)  
Spacer Section  
NUT Y85--29--N (3)  
WASHER Y14--625 (3)  
CONNECTOR  
See Figure 2  
SPRING 94457  
SPACER ROD 93233--2  
SPACER ROD 93233--1 (2)  
17-25/32  
(452 mm)  
Material Outlet  
3/4’’ NPTF--1(f)  
75_ FROM AIR EXHAUST  
PERFORMANCE  
Air Inlet Pressure Range . . . . . 30 -- 150 PSI (2 -- 10.3 bar)  
Fluid Pressure Range . . . . . . . 120 -- 600 PSI (8.3 -- 41.4 bar)  
Max. Rec’d Cycles / Minute . . . 70  
14-21/32  
(372 mm)  
Lower Pump  
66953--X43  
(See Manual 6695X--X)  
Displacement In3 Per Cycle . . . 82  
Volume/Cycle . . . . . . . . . . . . . 45.4 oz. (1343 ml)  
Cycles Per Gallon . . . . . . . . . . 2.8  
Flow @ 60 Cycles / Minute . . . . 21.3 GPM (80.6 lpm)  
Noise Level @ 60 Psi - 40 Cpm 84.8 db(A) *  
FIGURE 1  
Accessories Available: 91790 Silencer, 66101 Wall Bracket.  
* The pump sound pressure level has been updated to an Equivalent Continuous Sound  
Level (L ) to meet the intent of ANSI S1. 13--1971, CAGI--PNEUROP S5.1 using four  
Aeq  
IMPORTANT  
microphone locations.  
This is one of the four documents which support the pump.  
Replacement copies of these forms are available upon request.  
= 650632--X--C MODEL OPERATOR’S MANUAL  
- GENERAL INFORMATION -- INDUSTRIAL PISTON PUMPS  
- 6695X--X LOWER PUMP END OPERATOR’S MANUAL  
- 6564X--X AIR MOTOR OPERATOR’S MANUAL  
INGERSOLL RAND COMPANY LTD  
209 NORTH MAIN STREET – BRYAN, OHIO 43506  
(800) 495-0276 FAX(800) 892-6276  
© 2010  
CCN 99711836  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Intermec PDAs Smartphones CN2G User Manual
Jura Capresso Coffee Grinder IMPRESSA X7 S User Manual
JVC CRT Television 0403 NIC JMT User Manual
JVC CRT Television AV32L2EU AV28L2EU AV32X10EU AV28X10EU AV28WH5EU User Manual
JVC Portable CD Player XL PG3B User Manual
Kawasaki Radio VULCAN 1700 VOYAGER User Manual
Key Digital Network Card ES381 User Manual
KitchenAid Refrigerator KBFS25ETBL00 User Manual
Kodak Digital Camera Z1485 IS User Manual
Konica Minolta Digital Camera S404 User Manual