Ingersoll Rand Marine Sanitation System 65142X XX User Manual |
OPERATOR’S MANUAL
65142X-XX
RELEASED: 11-10-92
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
REVISED:
(REV. H)
12-11-07
MATERIAL FILTER
MAXIMUM INLET PRESSURE 6,000 P.S.I. (414 Bar)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
THIS MANUAL COVERS THE FOLLOWING MODELS:
CARBON STEEL 300 STAINLESS STEEL
CARTRIDGE
94597-3T
94597-30
93944-40
93944-70
93944-100
93944-200
MESH SIZE
None
30
651422-3T
651422-30
651420-40
651420-70
651420-100
651422-40
651422-70
651422-100
40
70
100
200
SERVICE KITS
Use only genuine ARO replacement parts to assure compatible
y
y
pressure rating and longest service life.
Refer to figure 3 to order replacement parts.
MATERIAL FILTER DATA
Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . see Model Description Chart
for “-XXX” (optional screen)
Material. . . . . . . . . . . . . . . . . . . . . . . . . . . see Model Description Chart
Maximum Fluid Pressure . . . . . . . . . 6,000 p.s.i.g. (414 bar)
OPERATING AND SAFETY PRECAUTIONS
Read and heed all warnings, cautions and safety precau-
y
tions before operating this pump.
HAZARDOUS PRESSURE. Can result in serious
WARNING
injury or property damage. Do not service or clean pump,
hoses or dispensing valve while the system is pressurized.
Be certain all operators of this equipment have
CAUTION
been trained for safe working practices, understand it’s
limitations, and wear safety goggles / equipment when re-
quired.
Figure 1
Do not exceed the maximum inlet air pressure
WARNING
as stated on the air motor model plate. Operating pump at
GENERAL DESCRIPTION
higher pressure may cause pump damage.
The ARO model 65142X-XX material filter is used to separate for-
eign materials, like dirt, stones and sweeping compound, from
the material handling section. Material filters and strainers can be
installed in a system to combat this problem, thereby achieving
longer service life. Filters and strainers are normally located in one
of two places in the pumping system. At this point, where the fluid
enters the material handling section, the strainer prevents foreign
material from entering the system.
HAZARDOUS MATERIALS. Can cause serious in-
WARNING
jury or property damage. Do not attempt to return a pump
to the factory or service center that contains hazardous
material. Safe handling practices must comply with local
and national laws and safety code requirements. Obtain
Material Safety Data Sheets on all materials from the sup-
plier for proper handling instructions.
DISASSEMBLY
1. Unscrew and remove (1) cap from the (7) body.
2. Remove (2) gasket from (1) cap.
3. Remove (3) spring and (4) button guide from the (7) body.
4. Pull the (6) cartridge and (5) ball from the (7) body.
INGERSOLL RAND COMPANY LTD
P.O. BOX 151 ONE ARO CENTER BRYAN, OHIO 43506-0151
y
y
© 2007
CCN 99445959
(800) 276-4658 FAX (800) 266-7016
y
ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
|