Ingersoll Rand Heat Pump AF1265SXXXXXX XX X User Manual

OPERATOR’S MANUAL & SALES AND ENGINEERING DATA  
RELEASED:  
(REV. 01)  
2-10-10  
INCLUDING: SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, TROUBLESHOOTING.  
INCLUDE MANUALS: AF1260-XX Air Motor (pn 97999-1474), 67300-XXX Lower Pump End (pn 97999-961) &  
S-632 General Information Manual (pn 97999-624).  
12” AIR MOTOR  
AF1265SXXXXXX-XX-X  
65:1 RATIO  
EXTRUSION PUMP SERIES  
6” STROKE  
Carbon Steel  
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,  
OPERATING OR SERVICING THIS EQUIPMENT.  
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.  
SERVICE KITS  
PUMP DATA  
Use only genuine ARO® replacement parts to assure compat-  
ible pressure rating and longest service life.  
MODEL AF1265SXXXXXX-XX-X  
637489 for repair of air motor section.  
637348-XXD for repair of lower pump end. Refer to the chart  
on page 2 for description of -XXX options.  
Air Inlet (female)  
3/4 - 14 N.P.T.F. - 1  
SPECIFICATIONS  
AF1260-XX Air Motor  
(see manual AF1260-XX)  
(refer to option chart)  
Model Series  
. . . . . . . . . . . AF1265SXXXXXX-XX-X  
Pump Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Operated, Extrusion  
Double Acting Pump  
“A”  
Spacer Section  
Connector (see figure 2)  
Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65:1  
Air Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AF1260-XX  
Motor Repair Kit. . . . . . . . . . . . . . . . . . . . . . . 637489  
Y6-128-C Hex Cap Screw (6)  
Y14-750-K Lock Washer (6)  
Motor Diameter . . . . . . . . . . . . . . . . . . . . . . . 12(30.5 cm)  
Stroke (double acting). . . . . . . . . . . . . . . . . 6(15.2 cm)  
Air Inlet (female) . . . . . . . . . . . . . . . . . . . . . . . 3/4 - 14 N.P.T.F. - 1  
Air Exhaust (female). . . . . . . . . . . . . . . . . . . . 1-1/4 - 11-1/2 N.P.S.M.  
Lower Pump End Series . . . . . . . . . . . . . . . . . . 67300-XXX  
Lower Pump Repair Kit . . . . . . . . . . . . . . . . 637348-XXD  
Material Outlet (female) . . . . . . . . . . . . . . . 1-1/4 - 11-1/2 N.P.T.F. - 1  
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 lbs (74.8 kgs)  
95438 Spring  
“B”  
93866 Spacer Rod (3)  
PUMP PERFORMANCE  
Air Inlet Pressure Range . . . 30 - 90 p.s.i.g. (2.1 - 6.2 bar)  
Fluid Pressure Range. . . . . . . . 1950 - 5850 p.s.i.g. (134.5 - 403.4 bar)  
Maximum Rec'd Cycles / Minute . . . . . . . . . 70  
Material Outlet (female)  
1-1/4 - 11-1/2 N.P.T.F. - 1  
“C”  
Displacement In.3 Per Cycle. . . . . . . . . . . . . . . . 20.0  
67300-XXX Lower Pump  
(see manual 67300-XXX)  
Volume / Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.08 oz. (327.6 ml)  
Cycles Per Gallon . . . . . . . . . . . . . . . . . . . . . . . . 11.55  
Flow @ 70 Cycles / Minute. . . . . . . . . . . . . . . . 6.06 g.p.m. (22.94 l.p.m.)  
Noise Level @ 60 p.s.i. - 40 c.p.m. . . . . . . . . 93.0 db(A)*  
Figure 1  
NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only.  
The pump sound pressure level has been updated to an Equivalent Continuous  
Sound Level (LAeq) to meet the intent of ANSI S1.13-1971, CAGI-PNEUROP S5.1  
using four microphone locations.  
*
(mm) (mm) (mm)  
“A”  
“B”  
30.375"  
“C”  
(489.0)  
19.250"  
(1304.9)  
(771.5)  
51.375”  
(for -1 model)  
53.460(1357.9)  
30.375" (771.5)  
19.250" (489.0)  
IMPORTANT  
This is one of four documents which support the pump. Re-  
placement copies of these forms are available upon request.  
AF1265SXXXXXX-XX-X Model Operator’s Manual (pn  
97999-1528)  
S-632 General Information - Industrial Piston Pumps (pn  
97999-624)  
67300-XXX Lower Pump End Operator’s Manual (pn 97999-961)  
AF1260-XX Air Motor Operator’s Manual (pn 97999-1474)  
INGERSOLL RAND COMPANY LTD  
209 NORTH MAIN STREET - BRYAN, OHIO 43506  
© 2010  
CCN 15334170  
(800) 495-0276 FAX (800) 892-6276  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL DESCRIPTION  
PUMP CONNECTION - UPPER / LOWER  
The chop-check pumps are primarily designed for the pumping  
of heavy viscous material with or without fibrous content. The  
models can be used with a gravity feed single post lift as a topper  
type assembly or with a two post lift as a force feed type assem-  
bly. The lower pump is designed for easy priming and the double  
acting feature is standard in all ARO industrial pumps. Material is  
delivered to the pump discharge outlet on both the up and down  
stroke.  
NOTE: All threads are right hand.  
1. Lay the pump assembly on a work bench.  
2. Remove the three (Y6-128-C) cap screws and (Y14-750-K) lock  
washers from the three spacer rods (see figure 1).  
3. Pull the air motor from the lower pump end until the motor  
piston rod is in the “downposition and the lower pump end  
rod is in the “upposition.  
4. Remove the three spacer rods by removing the three (Y6-128-  
C) cap screws and (Y14-750-K) lock washers.  
5. Using e-ring pliers, slide the “ering up far enough to allow the  
sleeve to move upward and release the two connectors (see  
figure 2).  
The motor is connected to the lower pump end by a spacer  
section. This allows for lubrication of the upper packing gland  
and prevents motor contamination because of normal wear and  
eventual leakage through the material packing gland. Be sure the  
solvent cup is adequately filled with lubricant to protect the upper  
packings and insure longest service life.  
HAZARDOUS PRESSURE. Do not exceed maxi-  
WARNING  
PUMP CONNECTION DETAIL  
mum operating pressure of 5850 p.s.i. (403.4 bar) at 90  
p.s.i. (6.2 bar) inlet air pressure.  
Pump Ratio X  
Inlet Pressure to Pump Motor  
=
Maximum Pump  
Fluid Pressure  
Pump ratio is an expression of the relationship between the pump motor area  
and the lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure  
is supplied to the motor of a 4:1 ratio pump, it will develop a maximum of 600  
p.s.i. (41.4 bar) fluid pressure (at no flow) - as the fluid control is opened, the flow  
rate will increase as the motor cycle rate increases to keep up with the demand.  
Pump Motor Piston Rod  
95069 “E” Ring  
94688 Connector (2)  
94689 Sleeve  
Refer to general information sheet for additional  
WARNING  
safety precautions and important information.  
NOTICE: Thermal expansion can occur when the fluid in the mate-  
rial lines is exposed to elevated temperatures. Example: Material  
lines located in a non-insulated roof area can warm due to sunlight.  
Install a pressure relief valve in the pumping system.  
Replacement warning label (pn 92325) is available upon  
request.  
Lower Pump Piston Rod  
TROUBLE SHOOTING  
Figure 2  
Pump problems can occur in either the air motor section or the  
lower pump end section. Use these basic guidelines to help deter-  
mine which section is affected.  
REASSEMBLY  
1. Align the pump motor with the lower pump end. Position the  
air inlet of the motor 120° from the material outlet.  
2. Install the two connectors (94688) and retain with the sleeve  
(94689). Slide the “ering (95069) back into position.  
3. Assemble the three spacer rods (93866) to the lower pump and  
secure using three (Y14-750-K) lock washers and (Y6-128-C)  
cap screws.  
Pump will not cycle.  
Be certain to first check for non-pump problems including  
kinked, restrictive or plugged inlet / outlet hose or dispens-  
ing device. Depressurize the pump system and clean out any  
obstructions in the inlet / outlet material lines.  
Refer to the motor manual for trouble shooting if the pump  
does not cycle and / or air leaks from the air motor.  
Damaged motor. Service the motor.  
4. Reinstall the spacer rods to the pump motor.  
5. Bring the motor and lower pump together and retain with  
three (Y14-750-K) lock washers and (Y6-128-C) cap screws.  
Pump cycles but does not deliver material.  
Refer to the lower pump end manual for further trouble shoot-  
ing.  
Page 3 of 4  
AF1265SXXXXXX-XX-X (en)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PERFORMANCE CURVES  
CYCLE PER MINUTE  
0
25  
50  
75  
6000  
5000  
4000  
3000  
2000  
1000  
300  
250  
200  
150  
100  
50  
90 PSI  
70 PSI  
70 PSI  
90 PSI  
40 PSI  
40 PSI  
0
0
2
4
6
0
U.S GALLONS PER MINUTE WATER DELIVER  
CYCLE PER MINUTE  
0
25  
50  
75  
400.00  
333.33  
266.67  
200.00  
133.33  
66.67  
18  
6.21 Bar  
4.83 Bar  
6.21 Bar  
4.83 Bar  
2.76 Bar  
15  
12  
9
2.76 Bar  
6
3
0.00  
0
8
16  
32  
0
LITERS PER MINUTE WATER DELIVER  
PN 97999-1528  
Page 4 of 4  
AF1265SXXXXXX-XX-X (en)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Infinity Speaker System TSS FMK4000 User Manual
InFocus Projector IN3116 User Manual
Jensen Car Amplifier XA4150 User Manual
JVC DVD Player XV S40BK User Manual
JVC VCR HR J280 User Manual
Kenmore Air Cleaner 152 User Manual
Kenmore Sewing Machine 010 User Manual
Kenwood Stereo Amplifier KAC PS811D User Manual
Kettler Patio Furniture 1038 000 User Manual
Klipsch Speaker V Series User Manual