Infinity Start System
User Guide
F849 Rev. 1005
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
1 Introduction
Receiving Your Equipment . . . . . . . . . . . . . . . . . . . . . .1-1
Scope of this Instruction Guide . . . . . . . . . . . . . . . . . . .1-1
Infinity Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Optional Equipment . . . . . . . . . . . . . . . . . . . . .1-2
Infinity Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
2 Setup
General Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
Infinity Connection Panel . . . . . . . . . . . . . . . .2-2
Using your Infinity with an Electronic Timer 2-3
Microphone . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
On/Off Switch . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Adjusting PA Volume . . . . . . . . . . . . . . . . . . . .2-3
Speakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
External Strobe . . . . . . . . . . . . . . . . . . . . . . . . .2-4
3 Using Your Infinity Electronic Start System
Starter's Microphone . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Strobe Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Timer Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Operating Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
4 Maintenance and Troubleshooting
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Cable Harness . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
In Case of Difficulty . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2
Returning Your Infinity for Service . . . . . . . . . . . . . . .4-4
Replacing the Battery . . . . . . . . . . . . . . . . . . . .4-4
i
Download from Www.Somanuals.com. All Manuals Search And Download.
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Introduction
Thank you for purchasing Colorado Time Systems’ Infinity start system.
Its multi-purpose design makes the Infinity perfect for use as an electronic
start system or a limited public address system. Instructions for both of
these applications are included in this manual.
Receiving Your Equipment
When you receive your Colorado Time Systems’ equipment, follow these
steps:
1) Open all shipping boxes.
Note: We recommend that you save all shipping boxes and packing material.
You are responsible for damage to your equipment if an item is returned
improperly packed.
2) Check all concealed damage immediately upon receipt of equipment.
Report any damage directly to the freight carrier.
3) Use the Packing List included with the shipment to take an inventory of
all items. If you believe one or more parts to be missing, contact our
Customer Service Department immediately. They can be reached by email:
[email protected], or by telephone: 800-279-0653 x 256
in the U.S. and Canada, or at 970-667-1000 x256.
Scope of this Instruction Guide
This instruction guide addresses all issues related to the installation and
normal operation of your Infinity start system. A complete maintenance
and troubleshooting section covers the most common problems that are
user correctable. For any repairs or problems not found in this instruction
guide, call Colorado Time Systems’ Customer Service Department, ext.
256, toll-free at 800-279-0653 (U.S. and Canada) or 970-667-1000.
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Infinity Start System Features
Your portable Infinity Start System contains a number of features which
make it versatile and easy to use. It also serves as a limited public address
system, allowing you to make announcements to your swimmers at prac-
tice and to the swimmers and spectators at a meet.
Add to these features the peace of mind you get from knowing Colorado
Time Systems stands behind you with more than thirty years of expertise
in designing and building accurate, reliable and innovative products.
Public address system to address swimmers and spectators. A 0.5 second
dual tone electronic blast with simultaneous strobe flash. False start
recall: repeating dual tone.
Functions
Each Infinity start system has a safe, reliable internal gel-cell battery with
external charger and battery life indicator. The Infinity will not operate
while plugged in to AC power.
Battery Power
Note: Your Infinity Start System can be operated only from battery power,
keeping AC power away from the pool deck and reducing the possibility of
electric shock.
Bright 360° strobe light automatically flashes simultaneously when horn
sounds. Gives watch timers/officials a reliable start reference; provides fair
starts to hearing-impaired athletes.
Strobe Light
Speakers
The Infinity includes one built-in 40-watt, 8 ohm moisture and corrosion
resistant reflex speaker. An additional speaker with is available for far
lane starting.
Single microphone used to address swimmers, start the race and recall in
the event of a false start.
Microphone
Mounting Options
Place the Infinity module on a tabletop or pool deck, or use the optional
CTS tripod (TR-3) with its mounting bracket.
Interfaces to all Colorado Time Systems’ electronic timers using start
jumper cable, Model INF-SJ25 (25-foot cable) or Model INF-SJ50M (50
meter cable).
Connection to electronic timer
The following optional equipment is available for use with your Infinity
Start System. Call your Colorado Time Systems at 1-800-279-0111 x250
(U.S. and Canada) or 970-667-1000 to place an order.
Optional Equipment
TR-3 Tripod: disassembles easily for storage. Adjustable height.
Portable.
INF-SP (125 or 200): 40-watt speaker with 125- or 200-foot cable for
far lane speaker mounting.
EXTSTROBE: External strobe light.
M-(25, 50, 100 or 200): Replacement Microphone with 25, 50, 100 or
200-foot cable.
INF-SJ (25 or 50M): Start jumper cable for electronic timer with 25-
foot or 50-meter length.
BP-3: Spare battery and external charger.
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Infinity Specifications
Model INF-SSM: Loudspeaker Start System consisting of a start module
General
with built-in strobe, built-in 40-watt corrosion-resistant speaker, internal
gel-cell battery, external battery charger wall brick, one plug-in micro-
phone, and instruction guide.
Height:
Length:
Width:
9.75 inches
14.25 inches
7.25 inches
12 lbs (5.4 kg)
Physical
Weight:
Temperature: 0°C - 50°C
Humidity: 90% (non-condensing)
Altitude: 0 to 3000 m
Environmental
DC Supply: 18 VDC @ 1.2A. The 18 V power adapter is used for recharg-
ing only.
Electrical, Base Unit
Note: Your Infinity Start System can be operated only from battery
power, keeping AC power away from the pool deck and reducing the possi-
bility of electric shock.
Type: One 12 V Gel Cell
Operating Time: 8 hours of normal use
Recharge Time: 8 hours
Battery
Fuses
Battery - 5A Time Lag, 5mm x 20mm
Input and Output
Connections
Microphone Ports: Input - 5V
External Charging Power: Input - 18 VDC @ 1.2A
Speaker Port: Output - 18 VAC @ 5A max.
Start Port: Opto - Isolator Transistor
This product is intended to be used in an indoor or outdoor swimming pool
environment. When it is operated in the United States, it must be used in
accordance with the National Electric Code. When it is operated elsewhere
it must be used in accordance with all applicable national and local codes
and regulations.
Installation/Maintenance
When charging, the Infinity Start System power supply must be used with
a grounded outlet. This equipment is intended to be connected to a circuit
protected by a ground-fault circuit interrupter when used outdoors or near
a pool. This product is equipped with a 3-wire grounding-type plug, a plug
having a third (grounding) pin. This plug will only fit into a grounding-
type power outlet. This is a safety feature. If you are unable to insert the
plug into the outlet, contact a qualified electrician to replace your obsolete
outlet. Do not defeat the purpose of the grounding-type plug.
Using the Infinity Start System in a manner not specified by Colorado
Time Systems may cause the protection provided by the equipment to be
impaired. Other than those maintenance items described in the Infinity
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
user manual, there are no user serviceable parts on the Infinity Start
System. When servicing those parts shown in the user manual, use only
replacement parts specified. Replacing of fuses or similar servicing shall be
performed only while the unit is disconnected from the source of supply.
Strobe
Speaker
Connector Panel
Figure A: Infinity Start System Components
1-4
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Setup
This chapter contains instructions for setting up your Infinity Electronic
Start System. The instructions in this chapter cover standard configura-
tions. Your start system configuration may vary depending on specific
requirements and optional equipment purchased.
General Guidelines
Select an appropriate location for your start system module—usually the
scorer’s table. Using the optional TR-3 tripod can give greater freedom to
place your Infinity in the most convenient location.
Location
Important: When installing your start system in a pool area, always place
the start system module in a location where there is no chance that it could
fall into the pool.
When using the built-in strobe light, the start system module should be
positioned so that officials and spectators can start their watches from the
strobe rather than the start tone, improving the accuracy of watch starts.
The Infinity start system operates on its built-in 12 VDC power source.
When the battery is fully charged, typical operation is eight hours, depend-
ing on usage. Using the microphone as a public address system sub-
stantially reduces battery life.
Battery
The Infinity connection panel has a battery life indicator LED. The LED
will shine green when the battery is fully charged. It will turn yellow when
the battery has 5-6 hours of use remaining. It is best to recharge the bat-
tery when the indicator turns yellow. The battery indicator will turn red
when only 1-2 hours of battery power remain. While the Infinity is plugged
in and charging, the LED flashes green, and turns solid green when
charged.
Battery Life Indicator LED
Green - fully charged
Yellow - needs charging
Red - almost out of power
Flashing green - charging
Battery Charging
Your Infinity will not operate while plugged into AC power for charging. It
is therefore important that you make sure the battery is fully
charged before each day’s swimming (the Battery Life indicator
should be green). Pay attention to the battery life indicator and
recharge your battery after each use, especially when the indicator turns
yellow. The Battery Life indicator will blink green on/off when charging.
The best time to recharge the internal battery is immediately after each
day’s use. To recharge the internal battery, remove the Infinity from the
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
pool area, plug the battery charger into a 115VAC outlet. Attach the cable
from the battery charger to the Charger connector on the Infinity con-
nection panel, shown in Figure B below. Turn the power switch to Off to
charge the battery. Keep the charger plugged in until the next use.
The charging circuit in the Infinity prevents overcharging, allowing you to
leave the battery charger plugged in for extended periods of time without
damaging the battery or any other components. If you do not use your
Infinity for two or more months, recharge the battery before use. It is nor-
mal for rechargeable batteries to lose some power when not in use.
The battery will lose 20% of its charge in two to three months if it
is not left plugged in.
Note: Make sure the power switch is in the Off position while charging.
An optional spare battery and external charger (BP-3) are also available
for facilities to ensure that their Infinity always has a charged battery
ready.
Note: Do not change the internal battery near water. Bring unit to a dry
location before removing internal battery.
12v Battery
Charger Input
Power Switch
Speaker Volume
Control
Battery Life
Indicator LED
Wired Microphone
or External Strobe
Inputs
CTS Timer Output
External Speaker
Figure B: Infinity Connection Panel
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are using your Infinity with an electronic sports timer, connect the
timer start cable from the cable harness or deck plate to the Start input on
your Infinity connection panel.
Using your Infinity with
an Electronic Timer
The Infinity sends only Normally Open (N.O.) start pulses, which work
with all Colorado Time Systems’ electronic timers. If your timer requires a
Normally Closed start pulse, contact your Colorado Time Systems repre-
sentative for factory modifications.
Connect the microphone to either of the microphone jacks on the Infinity
connector panel.
Microphone
Note: Your Infinity electronic start system is designed for use only with facto-
ry-supplied microphones.. For reliable operation, do not connect any other
devices other than CTS-supplied microphones or external strobes to the
microphone jacks.
To turn on your Infinity start system, flip the power switch to the On
position. The location of the power switch is shown in Figure B on page 2-
2. Regardless of start or PA operation, the Infinity consumes power when-
ever it is turned on. Therefore, it is very important that you remember to
flip the power switch to the Off position when your Infinity is not in use.
Failure to do so will result in a discharged battery after a few days. To pre-
vent battery discharge, always remember to turn off the power switch and
recharge the battery overnight as soon as possible after using your
Infinity.
On/Off Switch
To adjust the PA volume, turn on the Infinity, and adjust the volume knob
on the connector panel. Rotating the volume control clockwise increases
the volume; rotating the volume control counter-clockwise decreases the
volume. Test the volume level by speaking into the microphone.
Adjusting PA Volume
The volume control affects only the PA volume—start and recall tones
always function at maximum volume.
Note: To avoid feedback noise, do not hold the microphone close to the
speakers when testing the output volume. Also, turn the volume down to
decrease feedback.
The Infinity has one built-in speaker. At the start impulse, this speaker
amplifies the start tone.
Speakers
One optional external speaker can be added. When using an external
speaker, connect it to the External Speaker jack on the connector panel.
Note: Attach only the CTS-approved Infinity external speaker to the speaker
connector on your Infinity connection panel. Attaching any other type of
speakers can cause your start system to fail.
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
To connect the external strobe, plug one end of a DC3 cable into the
external strobe and the other end into either microphone 1 or 2 on the
infinity start system. Either microphone plug will work.
External Strobe
2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Using Your Infinity Electronic
Start System
Starter’s Microphone
To use the starter’s microphone for public address, press the push-to-
talk switch located on the top left side of the microphone and speak into
the grille on the front of the microphone.
To start a race, hold down the push-to-talk switch and press the start
button on the top left side of the microphone.
To recall a false start, hold down the push-to-talk switch and hold down
the start button a second time. The recall must be made within five (5)
seconds of the start pulse.
A convenient microphone rest is built into the Infinity to the left of the
connection panel. When the microphone is not in use, make a habit of
snapping the microphone on to the rest. Using the microphone rest keeps
the microphone out of the way and prevents accidental drops and potential
damage.
Microphone Rest
Strobe Light
Timer Output
The strobe light flashes automatically whenever the start system receives
a start pulse.
When properly connected to an electronic timing system, the Infinity auto-
matically sends a start pulse to the timer whenever the microphone start
button is pressed. If your electronic timer does not start properly, check
the start cable connections both at the timer cable harness or deck plate,
and at your Infinity.
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Notes
Using your Infinity electronic start system during training sessions is one
of its most useful features. Swimmers will quickly become accustomed to
electronic starting and will thereby improve their start reflexes.
Training
The volume control on the Infinity Connector Panel module affects only
the PA volume. The start and recall tones always operate at full volume. If
the start tone drops in volume or becomes longer, the battery is getting
low and needs to be recharged.
Volume Control
Battery Indicator
Check the Battery Life indicator LED to verify your battery’s remaining
power. Its different colors indicate:
Green - fully charged
Yellow - needs charging
Red - almost out of power
Flashing green - in charging mode
If coaches, parents and spectators attempt to start their stopwatches from
the start tone, they will not get accurate starts. The relatively slow speed
of sound (compared with the speed of light) generally results in late stop-
watch starts for observers at any distance from the speakers. Educate your
coaches, parents and spectators to use Infinity’s built-in strobe or external
strobe to trigger their stopwatch starts. The strobe flash is unaffected by
poor acoustics and the fast speed of light ensures that all observers see the
flash at the same time, resulting in more accurate stopwatch starts. The
strobe also ensures fair starts for hearing-impaired athletes.
Strobe Light Usage
3-2
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Maintenance and
Troubleshooting
This chapter contains maintenance and troubleshooting information
which helps you keep your Infinity in good working order and helps you
solve common problems quickly and easily.
Your Infinity electronic start system has been carefully designed to pro-
vide years of trouble-free service. No routine maintenance is necessary,
but following a few simple steps will ensure that your Infinity delivers the
trouble-free service for which it was designed.
You can extend the usable life of the internal battery by always keeping it
fully charged—never allow the battery to discharge completely. Leave the
Infinity plugged in when not in use and always make sure the power
switch is in the Off position after every use. If the Battery Life indicator
turns red, your battery needs immediate recharging. See page 2-1 for more
details.
Battery
Do not allow your speakers, speaker connections, cable harness terminals
and timer start cable connector to remain wet constantly. Colorado Time
Systems uses the finest quality materials available for these items, but the
pool environment is very harsh. The corrosive action of chemically-treated
Cable Harness
Storage
4-1
In Case of Difficulty
Colorado Time Systems has taken great care to ensure that your Infinity
electronic start system provides years of trouble-free service. If, however,
you should experience difficulties with your Infinity, first attempt to locate
and solve the problem using the Troubleshooting guide. Locate the prob-
lem you are experiencing and follow the remedies one at a time in the
order presented, checking your Infinity for proper operation between each
recommended remedy.
Solving simple problems yourself will save you time and money. If the
problem you are experiencing is not mentioned in the Troubleshooting
guide or the recommended steps do not solve the problem, call Customer
Service, ext. 256, toll-free at 800-287-0653 (U.S. and Canada) or 970-667-
1000 for assistance.
Troubleshooting
This section helps you solve common start system problems quickly.
Locate the difficulty you are experiencing in the Symptom column and
then follow the recommendations in the Action column one at a time, in
the order they appear. If the problem you are experiencing is not listed or
the recommended remedies do not have the desired effect, write a summa-
ry of the problem and all steps you have taken to correct it and call
Colorado Time Systems’ Customer Service Department, ext. 256, toll-free
at 800-CTS-0653 (U.S. and Canada) or 970-667-1000.
Symptom
Action
Notes
Nothing Works
1. Check power On/Off switch
If power switch is on, and the LED
indicator is red, the battery is discharged.
2. Recharge battery
See instructions beginning on page 2-1.
3. Check all connections on Infinity
Connector Panel.
See Figure B on page 2-2 for locations of
these items.
Battery will not charge
1. Check power AC outlet—use a working
lamp to check for power at outlet
2. Check charger connection on
the Infinity Connector Panel
See Figure B for location of this item. The
Battery indicator will flash green when
charging.
3. Replace battery
See instructions beginning on page 4-4.
4-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Action
Notes
Infinity does not start
electronic timer but start
horn sounds properly.
1. Check cable connections at timer,
cable harness (or deck plate) and Infinity.
2. Make sure you are using a Colorado
Time Systems timer (Normally Open
circuit)
3. Possible electronic timer failure —
attempt to start timer manually.
No start or recall tones at
speaker(s).
1. Make sure the starter is holding down See instructions on page 3-1.
the push-to-talk thumb switch when
pressing the start button on the
microphone.
2. Check wired microphone connector
on the Infinity connector panel.
See Figure B for location of this item.
3. Check speaker connector at external
speaker and on Infinity connector panel.
4. The microphone switch may be bad—
substitute another microphone.
No public address output at
speaker(s).
1. Check volume control level on the
Infinity connector panel.
See Figure B for location of this item.
See Figure B for location of this item.
2. Check speaker connector at external
speaker and on Infinity connector panel.
3. Check microphone connection on the
Infinity connector panel.
Strobe does not flash
1. Allow a few seconds between starts
for strobe to recharge.
2. Return Infinity to CTS for repair
Experiencing Feedback
1. Move further away from the base unit
or behind the speakers in use.
2. Turn down the speaker volume
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Returning Your Infinity For Service
If you are experiencing a problem not found in the Troubleshooting guide
or not corrected by the troubleshooting instructions, it may be necessary
to send part or all of your Infinity to the factory for service. Depending on
the problem, it may be necessary to return the entire start system. The
following list contains the components which can be returned to the facto-
ry individually after removal from the Infinity module.
Warning: Before attempting to remove any components, make sure the
Infinity power switch is in the Off position and the battery charger is
unplugged.
Detach the speaker connector from the Infinity module connector panel.
Return the defective speaker.
External Speaker
For any of the cables used, detach all connections and return the cable.
Cables
Return the entire system if you suspect that the strobe light portion of
your start system is damaged. First try the troubleshooting tips described
on page 4-3.
Strobe Light
If you have tried to charge the 12v battery and it no longer is holding a
charge, you may need to replace it with a new battery. The battery indica-
tor LED will shine red if, after charging, the battery did not hold the
charge.
12v Gel-cell Battery
To replace the battery, place the Infinity unit on a table in a dry location,
away from the pool deck.
1. With a Phillips-head
screwdriver, unscrew the
Battery
three screws on the back
battery cover as shown in
Figure C. Remove the back
panel of the Infinity.
Clip
Screws
2. Lift up the battery clip
and slide the 12-volt gel-
cell battery partway out so
you have easier access to
the connectors.
3. Disconect the two con-
nectors by wiggling them
from side to side while
pulling them off of the bat-
tery posts.
Figure C: 12v Battery Compartment
4. Remove the battery.
5. Lift up the battery clip and slide the new battery into the chamber with
the battery connectors facing the opening. Let the battery clip snap down
on to the battery to hold it in place.
4-4
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Connect the colored wire connectors to the corresponding connectors on
the battery. Do not pull excessively on the wires or you may dislodge them
from the main circuit board.
7. Replace the back panel and tighten the three screws to hold the panel in
place.
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Colorado Time Systems
1551 East 11th Street
Loveland, CO 80537 USA
Sales: U.S. and Canada: 1-800-279-0111 x250
Service: U.S. and Canada: 1-800-287-0653 x256
Sales and Service outside U.S. and Canada: +1 970-667-1000
Fax: 970-667-1032
4-6
Download from Www.Somanuals.com. All Manuals Search And Download.
|