Infinity Portable Generator CD 7 THRU CD 15 User Manual

TM  
CORONA DISCHARGE  
OZONE GENERATORS  
CD-7 THRU CD-15  
Main Power  
Ozone Power  
Vacuum  
High Coolant Temperature  
High Transformer Temperature  
Water Backflow Detector  
INSTALLATION & OPERATIONS MANUAL  
DEL INDUSTRIES, INC. · SAN LUIS OBISPO, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459  
012400 / 4-0401  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
1C. Warranty Summary  
LimitedWarranty:  
2 years on entire generator  
SECTION 1  
General Information  
In addition to the two (2) year warranty:  
3 years on weldments  
5 years on high voltage electrodes  
2 years on compressors that are maintained  
according to operation and maintenance manual.  
1A. Description  
The Infinity™ Corona Discharge series ozone generator  
described in this manual is designed to provide the ben-  
efits of ozonated water in an environmentally safe and  
effective manner. Infinity™generators are UL and NSF  
listed.The high quality, specially engineered components  
ensure efficient ozone output and reliable performance.  
SECTION 2  
Installation  
As a result of proper use of the Infinity™CD ozone gen-  
erators, unpleasant effects of traditional chemical use,  
(dry skin, red eyes, green hair) are virtually eliminated.  
The Infinity CD ozone generator is safe and harmless to  
2A. Location  
CD-7 and CD-15 are designed for either floor or wall mount-  
ing in a clean, protected area, either indoors or outdoors.  
Locate generator out of reach of sprinklers or drainage  
spouts. Allow sufficient access for maintenance and all  
tubing and electrical wires. Ozone generator should be  
installed no less than one foot above maximum water  
level.  
your equipment if installed properly.  
1B. Specifications  
Ozone Output:  
Ozone output (+10%): CD-7 .......... 7 g/hr  
CD-15 ........ 15 g/hr  
Flow rate (max):  
CD-7 .......... 7 scfh (3.5 lpm)  
CD-15 ........ 15 scfh (7 lpm)  
2.5-3.0%  
% weight O :  
3
Power Requirements:  
Domestic: CD-7 ..... 115VAC, 50/60 Hz, 1Ø, 6.0 Amp  
CD-15 .... 115VAC, 50/60 Hz, 1Ø, 7.5 Amp  
Export*: CD-7 ..... 230VAC, 50 Hz, 1Ø, 3.5 Amp  
CD-15 .... 230VAC, 50 Hz, 1Ø, 4.0 Amp  
CoolingWater Requirements:  
.1 GPM (.4 lpm) of clean, filtered, fresh water.  
NOTE:Typical pool water may be used for cooling.  
Generator efficiency and life will be improved at inlet  
temperatures of 80°F or less.  
Inlet temperature: 50°F - 90°F (10°C - 32°C)  
Inlet pressure:  
15.0 - 40 psi (100 - 270 kPa)  
ShippingWeight:  
CD-7: Approx. 135 pounds / 61 kilos  
CD-15: Approx. 150 pounds / 70 kilos  
Location Requirements**:  
Mounting:  
Floor or wall mount in a clean, protected  
area using supplied brackets.  
AmbientTemp:40°F - 100°F (5°C - 40°C)  
Ventilation: 6 air changes per hour.(min)  
Figure 1:Wall Mount  
* 230V/50Hz unit supplied with enclosed step down trans-  
former  
**Protection from weather elements must be provided for  
outdoor installations. Operating outside of the recom-  
mended temp. ranges may result in damage not covered  
under the manufacturers warranty.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
2B. Mounting  
2B-1.Wall Mount Option  
1. Attach two mounting brackets to wall using anchors  
appropriate for mounting surface. See figure 1.  
2. Using 1/4"-20 bolts (with washers as shown) se-  
cure generator to mounts.  
2B-2. Floor Mount Option  
1. Use the 4 1/4"-20 bolts with washers to secure feet  
to bottom of cabinet.  
2. Stand upright and securely fasten to concrete slab  
using appropriate anchors and bolts.  
2C. Electrical  
Main power circuit: Unit is supplied with a standard  
power cord. Plug cord into standard 110V grounded,  
grounding type receptacle only. NOTE: The circuit must  
be protected by a ground-fault circuit interrupter (GFCI)  
installed in accordance with electrical codes.  
2D. Plumbing  
Ozone gas is introduced to the pool circulation line using  
a venturi injector.Suction developed by the venturi allows  
the CD to operate safely under vacuum. See installation  
manual for MX-600-CD for proper venturi installation.  
2D-1. Ozone Gas Line  
1. Connect ozone tubing to generator outlet fitting.  
(3/8" stainless steel compression fitting.)  
2. Connect opposite end of ozone tubing to injector  
suction port. (Suction port fitting: 3/8" stainless  
steel compression fitting.) See figure 2.  
Figure 2: Plumbing Schematic  
2E. ORP Sensor Connection  
(For optional ORP Controller) Consists of mounting the  
NOTE:The ozone gas supply line must have a back flow  
prevention device (such as a check valve) installed be-  
tween the ozone generator cabinet and the point of  
injection to prevent water from backing up into the  
generator system. An ozone supply check valve is  
included with the MX-600-CD system.  
ORP probe and routing the sensor cables.  
2E-1. ORP Probe Mounting  
The sensor should be placed in the water stream at a  
point downstream from the ozone injector. See figure 2.  
1. Locate the point of insertion in the process pipe.  
NOTE: Install the ORP probe in a location which  
provides easy access for removal and cleaning of  
the probe.The probe should be installed such that  
the main stream ORP is measured. Locating the  
ORP probe upstream of the ozone measures the  
"pool" water.Locating the probe downstream of the  
ozone measures the ORP of water returning to pool.  
2. Install an appropriately sized tee in the process  
line or drill and tap a 1/2" FPT hole in the process  
pipe as shown in figure 3.  
2D-2. CoolingWater  
Cooling water must be supplied as specified in sec-  
tion 1B.  
1/4" FPT connections are supplied on the generator.  
See figure 2. Be sure that the tubing is appropriately  
matched with the marked inlet and outlet ports.Care-  
fully match and connect to water plumbing as shown  
in figure 2. Alternate method using connections at in-  
jector may be used.  
3. Remove the protective cap and apply Teflon tape  
to the sensor threads. Thread the sensor into the  
fitting or tapped hole. Save the protective sensor  
cap for storage.  
4. Start the circulation system and check for leaks  
around the sensor.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
Both (2) green indicator lights should be lit. If the optional  
ORP Controller is installed, it should be displaying a read-  
ing from the sensor probe and will automatically cycle the  
generator on and off as needed to maintain water quality.  
A high ORP (650-750 mV) is necessary for biological con-  
trol.  
However, the system will not start under any of the follow-  
ing conditions:  
1. If the optional ORP controller is installed the system  
will not start up if the ORP level is already above  
the setpoint of the ORP controller.  
Figure 3: ORP Probe  
2. The system will not start up if the door is not se-  
cured. A door interlock switch is incorporated into  
the system enclosure.  
3. The system will not start up if there is not enough  
vacuum being generated by water flow through  
injector.Red vacuum light will go out when proper  
vacuum is attained.  
2E-2. ORP Cable Routing:  
Route the cable away from other power wires and protect  
cable from damage. (i.e. Conduit or attached to plumb-  
ing.) Connect the sensor cable to the BNC connector lo-  
cated on the left exterior wall of the generator cabinet.  
4. System will not operate if there is too much  
vacuum. Red vacuum light will go out when  
proper vacuum is attained.  
SECTION 3  
Operation  
If you experience complications, seeTROUBLESHOOT-  
ING section 4C or call 800-676-1335 for assistance.  
3A. General  
To achieve optimal performance from the ozone system,  
the pool must be as clean as possible to start with.  
1. Backwash or clean filters one day before starting  
the ozone generator.  
3D. System Shut-Down  
The Infinity Corona Discharge ozone generator is a special-  
ized water cooled device that must be properly protected  
during shut-down/storage periods.The following sequence  
of steps must be used for servicing or for storage.  
1. Toggle the main system power switch to theOFF”  
position to shut down generator.  
2. Superchlorinate pool water using a chlorine based  
shock treatment.  
3. Test pool chemistry and adjust pH between 7.4 and  
7.6. Adjust total alkalinity between 80 and 120 ppm.  
4. Run pool filtration continuously for 24 hours prior to  
starting ozone system.  
2. After the generator has been shut down, the pro-  
cess water circulation pump may be turned off.  
3. If the system is going to be shutdown and stored  
during freezing weather, it is very important that  
the cooling water jacket be drained to protect it from  
rupture or damage.  
3B. Initial System Start-Up  
Upon completing all of the generator system connections  
and cleaning the pool as outlined above, you are ready to  
begin start up procedures.  
1. Check electrical fittings.  
2. Check for proper voltage.  
3. Turn on circulation pump.  
4. Check for leaks.  
NOTE:Process water flow must not be shut down when  
the ozone generator is operating. Doing so may cause  
water to backflow into the system and damage the gen-  
erator module and electrodes.  
5. Check cooling water.  
6. Adjust injector by-pass to attain required vacuum.  
(Red vacuum light will go out)  
7. Turn main power switch to "ON" position.  
3E. Water Chemistry  
Regular chlorine/bromine testing should be performed as  
normal. Ozone will be eliminating the majority of contami-  
nants. Therefore, only a small amount of chemicals will  
need to be added - just enough to maintain a minimum of  
residual level of .5-1.0 ppm chlorine or 1.0-2.0 ppm bro-  
mine. Ozone has very little if any impact on pH, reducing  
pH adjustments to a minimum.  
3C. Normal Operation  
At this point, the systems cooling fans will start up. The  
oxygen concentrator will begin operating and the output  
solenoid valve will open.The ozone generator should be  
producing ozone and injecting it into the process line.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
4A-3. Internal Components  
SECTION 4  
Maintenance and Service  
1. Corona Discharge (CD) Module: Generator  
module consists of stainless steel water jacket  
and ground tubes and two end housings.  
4A. System Electro-Mechanical Overview  
Refer to Figure 4 for component locations.  
4A-1. Indicator Lights  
Enclosed inside the module are the high voltage  
glass tube electrodes.The top end housing (the  
cylindrical glass chamber) encloses the high  
voltage connection for the electrodes and allows  
for visual inspection.  
1. Main Power: Green light indicates that power is  
being supplied to the ozone generator.  
2. Ozone Power: Green light indicates that power is  
being supplied to the high voltage Corona Discharge  
circuits and that ozone is being produced.  
3. Vacuum:Red light indicates proper vacuum being  
supplied from the venturi injector.Light will be lit for  
either low or high vacuum conditions.  
4. High Coolant Temperature: Red light indicates  
coolant temperature is over 150°F - resulting from  
loss of cooling water flow. (Refer to TROUBLE-  
SHOOTING section.)  
5. HighTransformerTemperature: Red light indicates  
transformer temperature is over 150°F - resulting  
from high current through the transformer.(Refer to  
TROUBLESHOOTING section.)  
6. Water Backflow Detected:Red light indicates wa-  
ter backflow from injector into generator. (Refer to  
TROUBLESHOOTING section.)  
2. HighVoltageTransformer(s):Transformer raises  
supplied voltage up to the voltage necessary for  
ozone production.Transformer is thermally  
protected by a temperature switch attached to the  
transformer casing.  
3. Air Compressor: Compressor produces and  
supplies compressed air to oxygen concentrator.  
4. Oxygen Concentrator: Supplies concentrated,  
dry, oxygen feed gas to the ozone generator.  
5. Lo Limit Vacuum Switch: If the vacuum in the  
ozone output supply line falls below 2 in. Hg the  
switch will open causing the system to shut down.  
6. Hi Limit Vacuum Switch: If the vacuum in the  
ozone output supply line rises above 10 in. Hg the  
switch will open causing the system to shut down.  
7. Water Backflow Detector:Backflow detector  
senses water present in ozone tubing in generator.  
If water is detected, system will close solenoid  
valve to prevent additional water backflow from  
occuring.Water in the generator will cause severe  
damage to the high voltage electrodes.  
8. Ventilation Fan:Cooling fan operates when main  
power switch is ON.  
9. Air Filter: Filter cleans ventilation air entering the  
enclosure.  
10. Door Interlock Switch: Interlock switch will shut  
down entire system if door is opened. Securing  
the door will bring the system back into operation.  
11. Relay Panel: Contains control relays for system  
interlocks, indicator lights and main power control.  
4A-2. Remaining External Components  
1. Main Power Switch:Power switch is used for sys-  
tem start-up and shut-down. Switch activates the  
control system allowing the generator to start up.  
2. Flowmeter: Flowmeter controls and indicates the  
oxygen flow through the system.  
3. Circuit Breaker: Circuit breaker protects the gen-  
erator from over current conditions. Push the breaker  
button to reset.  
4. ORP Controller (optional): ORP controller receives  
a millivolt (mV) signal from the ORP sensor mounted  
in the process water line. ORP (Oxidation-Reduc-  
tion Potential) is a measure of the relative oxida-  
tion strength of the water.As ozone is added to the  
water system the ORP level will rise. As ozone is  
used up in the water system the ORP level will  
drop.The ORP controller continuously analyses the  
sensor signal, compares it to the setpoint that has  
been programmed, indicates the ORP level on the  
digital display, and relays the signal to the ozone  
generator.  
4B. Preventative Maintenance Schedule  
The InfinityCorona Discharge ozone system requires very  
little maintenance beyond general housekeeping practices.  
DAILY:  
1. Check ozone generator for proper operation.  
- Make sure no red indicator lights are lit.  
- Make sure flow meter is indicating proper air flow.  
2. Practice normal pool maintenance.  
MONTHLY:  
5. Variac (Optional):Variac adjusts high voltage  
power supplied to the ozone generator module  
controlling ozone output concentration.  
1. Remove and clean ORP probe.  
- Remove from water stream.  
- Clean tip of probe with non-abrasive cleanser to  
remove any contaminant build up on probe.  
- If there is a heavy build up on probe surface,  
clean with a mild muriatic solution.  
- Rinse and return to water stream.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
Figure 4: Component Locations  
2. Remove and clean air filter.  
8. Gently glide glass tube electrodes out from module.  
Inspect for damage.  
9. Wipe down electrodes using a solvent such as de-  
natured alcohol and set in a safe area.  
- Remove filter housing to access filter.  
- Rinse filter in warm, soapy water and blow dry.  
- Replace filter.  
3. Perform general cleaning of cabinet interior.  
ANNUALLY:  
10. Swab out the stainless steel tubes using a solvent  
such as denatured alcohol or acetone.  
1. Remove, disassemble and clean CD module.  
See GENERATOR SERVICING section 4C.  
BIANNUALLY:  
11. Replace electrodes - be sure to wipe off any finger-  
prints, and reassemble module in reverse order.  
1. Rebuild compressor.  
4C-2. Air Compressor  
See GENERATOR SERVICING section 4C.  
Air compressor requires a rebuild every two (2) years  
or 15,000 hours of operation.  
1. Purchase rebuild kit from DEL Industries, Inc.  
See Section 5 for ordering information.  
2. Follow instructions in kit to rebuild compressor.  
4C. Generator Servicing  
Before performing any servicing to the ozone generator,  
make sure the power is off by disconnecting electrical  
plug from wall socket.  
4C-1. Corona Discharge (CD) Module  
1. Disconnect the wires from the thermostat switch and  
ground terminal attached to the generator housing.  
2. Unplug high voltage cable(s) from the top end of  
the CD module.  
4D. Trouble Shooting  
Knowledge of electrical applications is required for  
trouble shooting. Contact a certified electrician if you  
are unsure of your ability to service the equipment.  
If any condition persists, call 800-676-1335 for  
technical assistance.  
3. Very carefully disconnect the oxygen feed and  
ozone output lines by removing the stainless steel  
compression nuts.  
Symptom: Main powerlight out when system switch is  
in the "ON" position.  
1. No power to the generator module from the power supply:  
a. Check the circuit breaker at the facility power dis-  
tribution box.  
4. Drain cooling water from ozone module and dis-  
connect cooling water lines.  
5. Remove module from cabinet.  
b. Check for loose connections or wiring breaks  
from the power distribution box to the generator.  
6. Carefully remove glass end housing, inspect for  
damaged glass or retainer springs, and set aside.  
7. Remove the opposite end (aluminum discharge end)  
taking care not to lose retainer springs. Inspect for  
damage and set aside.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
2. G.F.C.I. has tripped.*  
2. Excessive ambient temperatures in installation area.  
a. Generator should not be exposed to ambient  
temperatures above 100°F. Higher temperatures  
may damage generator components.  
a. Check power cord and reset G.F.C.I.  
3. Circuit breaker has tripped.*  
a. Reset breaker.  
*If G.F.C.I. or breaker continue to trip after reset, call  
for technical assistance.  
Symptom:Water backflow detectedindicator light is on.  
1. Water has backed into generator from injector.  
a. Establish proper water flow through injector and  
correct suction.  
Symptom: Ozone powerindicator light out.  
1. If optional ORP is installed, ORP may have shut down  
the generator when ORP level reached setpoint.  
a. Wait for ORP to come down.Generator will  
restart when ORP level is below set point.  
2. Abnormal operating condition exists.  
b. Drain Back Flow Preventer by first routing drain  
tubing out of cabinet.opening cabinet and opening  
1/4" stainless steel ball valve.  
c. After water has completly drained close drain  
valve, secure cabinet door and restart system.  
a. Check red fault indicator lights. Refer to corre-  
sponding symptom and corrective action.  
Symptom: CD Module is not operating. Ozone output  
has dropped.  
1. No power to the generator module from the power supply:  
a. Check H.V.cables for breaks or loose connections,  
replace if necessary.  
Symptom:Vacuumindicator light is on indicating out of  
range vacuum being supplied.  
1. Injector not supplying adequate suction.  
a. Check pump and ensure water is flowing through  
injector.  
b. Check for power at input terminals of the H.V.  
transformers.*  
c. Check ozone power relay for loose connections  
or faulty operation.  
b. Check by-pass valve and adjust if necessary to  
obtain proper pressure differential in order to  
reestablish suction.  
2. Injector supplying too much suction.  
a. Check by-pass valve and adjust to obtain proper  
suction.  
b. Check system back pressure and increase to  
reduce suction.  
3. Another abnormal condition exists causing ozone out-  
put solenoid valve to be closed.  
*CAUTION:HIGHVOLTAGE.  
Symptom:No air flow through the generator.The air flow  
meter indicates 0 scfh flow.  
1. Flowmeter control valve is improperly set:  
a. Open flowmeter valve until proper air flow is  
indicated (~8 scfh for CD-7, ~14 scfh for CD-15).  
2. Air compressor is not operating properly.  
a. Listen for air compressor operation.  
a. Check red fault indicator lights. Refer to corre-  
sponding symptom and corrective action.  
b. Solenoid valve may be stuck in closed position.  
Free solenoid plunger and return system to  
normal operation.  
b. Check all tubing connections from the air compres-  
sor through the system for leaks.  
SECTION 5  
Replacement Parts and Order Information  
Symptom: High coolant temperatureindicator light is  
on indicating ozone module temperature over 150°F.  
1. Coolant water flow has been interupted.  
a. Check all tubing connections, ensureing tight,  
leak free connections.  
5A. Ordering information:  
For replacement parts call DEL at 1-800-676-1335.  
Be prepared with the following information:  
· Customer Name · Customer Address  
· DEL Model Number · DEL Serial Number  
· Date Purchased · Proof of Purchase  
b. Trace tubing and look for blockage of flow.  
c. Re-establish proper coolant water flow.  
Symptom: High transformer temperatureindicator light  
is on indicating high voltage transformer temperature over  
150°F.  
5B. Standard replacement parts list:  
1. Compressor rebuild kit, CD-7 .................. 9-1007  
2. Compressor rebuild kit, CD-15 ................ 9-1015  
3. Ventilation air filter................................... 7-0401  
4. High voltage electrode............................. 9-0540  
5. Ozone tubing, Teflon ............................... 7-0126  
6. Ozone tubing, Stainless Steel ................. 8-0098  
7. Ozone module gasket (1 ea.) .................. 7-0801  
8. Installation & Operations Manual ............ 4-0401  
1. Enclosure ventilation is blocked.  
a. Check air filter on bottom left-hand side of  
enclosure for blockage.  
b. Clear blockage or clean filter.  
c. Restart system and allow transformer to cool.  
When temperature returns to normal system will  
return to normal operation.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
DEL INDUSTRIES, INC.  
LIMITED WARRANTY  
The limited warranty set forth below applies to products manufactured by DEL INDUSTRIES, Inc. - 3428  
Bullock Lane, San Luis Obispo, California 93401, and sold by DEL INDUSTRIES and its authorized dealers.  
This limited warranty is given only to the first retail purchaser of such products and is not transferable to any  
subsequent owners or purchasers of such products.  
DEL INDUSTRIES warrants that it or its authorized dealers will repair or replace, at its option, any part of  
such products proven to be defective in materials or workmanship within two (2) years of the date of final  
commissioning by DEL INDUSTRIES or its authorized agent.Warranties on systems not commissioned by  
an authorized DEL INDUSTRIES representative shall be deemed null and void. DEL INDUSTRIES reserves  
all rights to determine and authorize DEL INDUSTRIES representatives.This policy pertains to ALL instal-  
lations.This warranty is extended to three (3) years on weldments and five (5) years on high voltage  
electrodes. Compressors shall be covered under the two (2) year warranty when, and only when, maintained  
per operation and maintenance manual. Required maintenance includes a compressor rebuild after one (1)  
year.Warranty does not include parts for rebuild kit.This warranty specifically excludes any components  
not manufactured by DEL INDUSTRIES that are external to the products covered, such as pumps, air  
compressors, monitors or related components. DEL INDUSTRIES will assist with all warranty claims for  
such components purchased through DEL INDUSTRIES;limited to the extent of the manufacturers stan-  
dard warranty. ANY REPAIR OR REPLACEMENT WILL BE WARRANTED ONLY FORTHE BALANCE OF  
THE ORIGINALWARRANTY PERIOD.  
NOTE:  
USE ONLY DEL AUTHORIZED REPLACEMENT PARTS. USE OF ANY OTHER PART(S)WILL  
AUTOMATICALLYVOIDTHISWARRANTY.  
Any replaced parts must be returned to DEL Industries for evaluation.  
THIS LIMITEDWARRANTY DOES NOT INCLUDE ANY OFTHE FOLLOWING: (a) any repair or replace-  
ment of such parts necessitated by faulty installation, improper maintenance, improper operation, misuse,  
abuse, negligence, accident, fire, repair materials, and/or unauthorized accessories; (b) any such products  
installed without regard to required local codes and accepted trade practices; (c) ANY IMPLIED WAR-  
RANTY OF MERCHANTABILITY OR IMPLIEDWARRANTY OF FITNESS FOR PARTICULAR PURPOSE,  
AND SUCHWARRANTIES ARE HEREBY DISCLAIMED;AND (d) DEL INDUSTRIES SHALL NOT BE  
LIABLE UNDER ANY CIRCUMSTANCES FOR LOSS OF USE OF SUCH PRODUCTS, LOST PROFITS,  
DIRECT DAMAGES, INDIRECT DAMAGES, CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL  
DAMAGES.  
This warranty gives you specific legal rights.You may have other rights which vary from state to state.  
TO OBTAINWARRANTY SERVICE:  
DEL Industries, Inc.CD Department  
3428 Bullock Lane, San Luis Obispo, CA 93401  
Customer Service Number: 800-676-1335  
Fax Number:805-541-8459  
PROVIDE:  
1. Project, contact name, mailing address and telephone number.  
2. Installer/Mechanical Contractor.  
3. Serial # and date of commissioning.  
4. The date of failure.  
5. A description of the failure.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
APPENDIX “A”  
SAFETY  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator  
HEALTH HAZARDS OF OZONE  
FIRST AID  
Detection Levels  
General  
Ozone can be detected in air by its distinctive odor at  
concentrations of about 0.02 ppm. Although each nose  
varies, olfactory fatigue occurs quickly. As a result, DO  
NOT RELY ON ODOR AS AWARNING OF HIGH  
OZONE CONCENTRATIONS.  
First Action  
1. If exposure to ozone causes headache or shortness  
of breath, immediately remove the patient to a fresh  
air environment.  
Second Action  
1. Workers who have been exposed to low concentra-  
tions of ozone should be given oxygen to breathe  
while under the observation of trained personnel.  
2. If exposure is sever, send for medical assistance  
immediately.  
The permissible exposure level (PEL) or time weighted  
concentration for ozone to which workers may be  
exposed os 0.1 ppm averaged over 8 hours, 5 days a  
week (OSHA).The short term exposure limit is 0.3 ppm  
average over 15 minutes.The concentration of 10 ppm  
ozone in air is generally accepted as immediately  
Dangerous to Life or Health (DLH).  
Inhalation  
First Action  
Effects on Humans  
1. Assess patient's breathing.  
2. All unconscious patients must be placed in the  
drainage position (on their sides), so that fluids can  
drain from the airways once breathing has been  
restored.  
3. Check pulse.  
Second Action  
1. If breathing has ceased, start artificial respiration  
(rescue breathing is the most effective) method until  
breathing has been restored.  
Ozone acts as a primary irritant, affecting mainly the  
eyes, upper respiratory tract and the lungs. Onset of  
pulmonary edema (fluid buildup in the lungs) may be  
delayed for a few hours after exposure. Inhaling ozone  
at concentrations of 50 ppm for 30 minutes can be fatal.  
Many people exposed to airborne ozone rapidly develop  
a headache, which often disappears after a few minutes  
in fresh air.  
2. Send for medical assistance immediately.  
3. If absent, begin cardiopulmonary resuscitation  
(CPR).  
Reduction in lung function due to scar tissue forming in  
the lung may occur due to long-term exposure to ozone  
at concentrations above 0.2 ppm, or a single high  
exposure. Although medical studies show no evidence  
of ozone causing cancer or lung allergies or harming the  
unborn, there is some evidence that the oxidizing power  
of ozone could lead to premature aging of the body as a  
whole.  
Eye Contact  
First Action  
1. Effective irrigation should start immediately. Eyes  
should be irrigated for 30 minutes by the clock with  
running tap water or preferably normal saline.  
Second Action  
1. Effective irrigation must be continued while en route  
to hospital.  
The owner of any ozone installation should advise any  
person who may be exposed to ozone that those with a  
history of heart or respiratory disease should take every  
precaution to avoid exposure to ozone.  
Precautions  
Workers with a previous cardiopulmonary (heart and  
lung) condition must consult their physician prior to  
working in an area in which they may be exposed to  
ozone. Significant alterations in cardiopulmonary  
functions have been documented when such workers  
have been exposed to low concentration of ozone.  
END OF DOCUMENT.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  

Insignia Computer Monitor NS 24EM51A14 User Manual
Interlink electronic Computer Accessories 94 01441 User Manual
ION Turntable QUICK PLAY FLASH User Manual
Ives Door 7253 User Manual
Ives Heat Pump S 634 User Manual
John Deere Lawn Mower 335C User Manual
Johnson Controls Film Camera R 22 S1 1TVM2 User Manual
JVC Stereo System CA MXKB1 User Manual
JVC VCR HR J245EE User Manual
Kodak Scanner A 61576_EN User Manual