Hitachi RAS 80YHA User Manual

SPLIT TYPE  
INDOOR UNIT/OUTDOOR UNIT  
MODEL  
RAS-80YHA/RAC-80YHA  
INDOOR UNIT  
OUTDOOR UNIT  
RAS-80YHA  
RAC-80YHA  
Instruction manual  
Page 1~22  
To obtain the best performance and ensure years of trouble free use, please read this instruction  
manual completely.  
PRECAUTIONS DURING OPERATION  
G
The product shall be operated under the manufacturer specification and  
not for any other intended use.  
G
Do not attempt to operate the unit with wet hands, this could cause fatal  
accident.  
G
When operating the unit with burning equipments, regularly ventilate the  
room to avoid oxygen insufficiency.  
G
Do not direct the cool air coming out from the air-conditioner panel to face  
household heating apparatus as this may affect the working of apparatus  
such as the electric kettle, oven etc.  
G
Please ensure that outdoor mounting frame is always stable, firm and  
without defect. If not, the outdoor unit may collapse and cause danger.  
G
Do not splash or direct water to the body of the unit when cleaning it as this  
may cause short circuit.  
G
Do not use any aerosol or hair sprays near the indoor unit. This chemical  
can adhere on heat exchanger fin and blocked the evaporation water flow  
to drain pan. The water will drop on tangential fan and cause water splashing  
out from indoor unit.  
C
A
U
T
I
G
Please switch off the unit and turn off the circuit breaker during cleaning, the  
high-speed fan inside the unit may cause danger.  
O
N
G
Turn off the circuit breaker if the unit is not to be operated for a long period.  
G
Do not climb on the outdoor unit or put objects on it.  
G
Do not put water container (like vase) on the indoor unit to avoid water  
dripping into the unit. Dripping water will damage the insulator inside the unit  
and causes short-circuit.  
G
Do not place plants directly under the air flow as it is bad for the plants.  
G
G
When operating the unit with the door and windows opened, (the room humidity is always above  
80%) and with the air deflector facing down or moving automatically for a long period of time,  
water will condense on the air deflector and drips down occasionally. This will wet your furniture.  
Therefore, do not operate under such condition for a long time.  
If the amount of heat in the room is above the cooling or heating capability of the unit (for  
example: more people entering the room, using heating equipments and etc.), the preset room  
temperature cannot be achieved.  
G
G
This appliance is not intended for use by young children or infirm persons unless they have been  
adequately supervised by a responsible person to ensure that they can use the appliance safely.  
Young children should be supervised to ensure that they do not play with the appliance.  
3 –  
NAMES AND FUNCTIONS OF EACH PART  
INDOOR UNIT  
AIR FILTER  
To prevent dust from coming into the  
indoor unit.  
(Refer page 21)  
FRONT PANEL (AIR INLET).  
INDOOR UNIT INDICATORS  
Light indicator showing the operating  
condition.  
(Refer page 5)  
G
HORIZONTAL DEFLECTOR  
VERTICAL DEFLECTOR (AIR  
OUTLET)  
(Refer page 16)  
G
REMOTE CONTROLLER  
Send out operation signal to the indoor  
unit. So as to operate the whole unit.  
(Refer page 6)  
OUTDOOR UNIT  
AIR INLET (BACK, LEFT SIDE)  
AIR OUTLET  
Blow out warm air.  
MODEL NAME AND DIMENSIONS  
DEPTH (mm)  
MODEL  
WIDTH (mm)  
1150  
HEIGHT (mm)  
245  
315  
RAS-80YHA  
RAC-80YHA  
333  
875  
925  
4 –  
OPERATION INDICATOR  
TEMPORARY SWITCH  
Temporary Switch  
Press  
Non-conductor Stick  
Use this switch to start and stop when the remote  
controller does not work. [Use non-conductor stick  
(example toothpick)]  
G By pressing the temporary switch, the operation is  
done in previously set operation mode.  
G When the operation is done using the temporary switch  
after the power source is turned off and turn on again,  
the operation is done in automatic mode.  
INDOOR UNIT INDICATORS  
TIMER LAMP  
This lamp lights when the timer is working.  
OPERATION LAMP  
This lamp lights during operation.  
The OPERATION LAMP flashes in the following cases  
during heating.  
(1) During preheating  
For about 23 minutes after starting up.  
(2) During defrosting  
Defrosting will be performed about once an hour  
when frost forms on the heat exchanger of the  
outdoor unit, for 510 minutes each time.  
FILTER LAMP  
When the device is operated for a total of about 200  
hours, the FILTER lamp lights to indicate that it is time  
to clean the filter. The lamp goes out when the  
(AUTO SWING)button is pressed while the  
device is on STANDBY MODE.  
5 –  
NAMES AND FUNCTIONS OF EACH PART  
REMOTE CONTROLLER  
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting  
is controlled electronically, the range of control may be shorter.  
This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can  
be controlled from the remote controller.  
G Signal emitting window/transmission sign  
Point this window toward the indoor unit when controlling it.  
The transmission sign blinks when a signal is sent.  
G Display  
This indicates the room temperature selected, current time, timer status,  
function and intensity of circulation selected.  
G START/STOP button  
Press this button to start operation. Press it again to stop operation.  
G FAN SPEED selector  
This determines the fan speed. Every time you press this button, the intensity  
of circulation will change from (AUTO) to (HI) to (MED) to (LOW)  
(during the  
(FAN) mode, from  
HI to  
MED to  
LOW).  
G AUTO SWING button  
Controls the angle of the horizontal air deflector.  
G TEMPERATURE buttons  
Use these buttons to raise or lower the temperature setting. (Keep pressed,  
and the value will change more quickly.)  
G SLEEP button  
Use this button to set the sleep timer.  
G TIME button  
Use this button to set and check the time and date.  
G RESET buttons  
G FUNCTION selector  
Use this button to select the operating mode. Every time you press it,  
the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to  
(COOL) and to  
(FAN) cyclically.  
G PARALLEL SWING button  
Controls the angle of the vertical air deflectors to parallel.  
G SYMMETRY SWING button  
Controls the angle of the vertical air deflectors to symmetry.  
G TIMER control  
Use this button to set the timer.  
G OFF-TIMER button Select the turn OFF time.  
G ON-TIMER button Select the turn ON time.  
G RESERVE button Time setting reservation.  
G CANCEL button Cancel time reservation.  
Precautions for Use  
G Do not put the remote controller in the following places.  
G In direct sunlight.  
G In the vicinity of a heater.  
G Handle the remote controller carefully. Do not drop it on the floor,  
and protect it from water.  
G Once the outdoor unit stops, it will not restart for about 3 minutes  
(unless you turn the power switch off and on or unplug the power  
cord and plug it in again).  
This is to protect the device and does not indicate a failure.  
G If you press the FUNCTION selector button during operation, the  
device may stop for about 3 minutes for protection.  
– 6 –  
VARIOUS FUNCTIONS  
I Auto Restart Control  
G
G
If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode  
and airflow direction.  
(As the operation is not stopped by remote controller.)  
If you intend not to continue the operation when the power is resumed, switch off the power supply.  
When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and airflow  
direction.  
Note: 1. If you do not require Auto Restart Control, please consult your sales agent or OFF by remote control.  
2. Auto Restart Control is not available when Timer or Sleep Timer mode is set.  
AUTOMATIC OPERATION  
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current room  
temperature. The selected mode of operation will change when the room temperature varies.  
Press the FUNCTION selector so that the display indicates the  
(AUTO) mode of operation.  
G
When AUTO has been selected, the device will automatically determine the mode of  
operation, HEAT, COOL or DEHUMIDIFY depending on the current room temperature.  
If the mode automatically selected by the unit is not satisfactory, manually change the  
mode setting (heat, dehumidify, cool or fan).  
G
1
START  
STOP  
Press the  
Operation starts with a beep.  
Press the button again to stop operation.  
(START/STOP) button.  
RESET  
I
As the settings are stored in memory in the remote controller, you only have to press the  
(START/STOP) button next time.  
You can raise or lower the temperature setting as necessary by maximum of 3°C.  
Press the temperature button and the temperature setting will change by  
°C  
1°C each time.  
G
G
The preset temperature and the actual room temperature may vary somewhat depending on  
conditions.  
The display does not indicate the preset temperature in the AUTO mode. If you change the  
setting, the indoor unit will produce a beep.  
Press the  
(FAN SPEED) button, AUTO and LOW is available.  
I Condition of Automatic Operation  
Initial room temperature  
Function  
Temperature setting  
27°C  
FAN SPEED  
(approx.)  
HI at start, MED or LOW  
after the preset temperature  
is reached  
Over 27°C  
23~27°C  
COOL  
DEHUMIDIFY  
HEAT  
Slightly lower than the  
room temperature  
LOW  
HI at start, MED or LOW  
after the preset temperature  
is reached  
Under 23°C  
23°C  
– 7 –  
HEATING OPERATION  
G Use the device for heating when the outdoor temperature is under 21°C.  
When it is too warm (over 21°C), the heating function may not work in order to protect the device.  
Press the FUNCTION selector so that the display indicates  
(HEAT).  
1
Set the desired FAN SPEED with the (FAN SPEED) button  
(the display indicates the setting).  
(AUTO): The fan speed is HI at first and varies to  
MED or LOW automatically when the preset  
temperature has been reached.  
2
(HI)  
: Economical as the room will become warm  
quickly.  
But you may feel a chill at the beginning.  
(MED) : Quiet.  
(LOW) : More quiet.  
Set the desired room temperature with the TEMPERATURE  
buttons (the display indicates the setting).  
The range of 18-22°C is recommended as the  
room temperature for heating.  
If the temperature setting is 20°C, the room  
temperature will be controlled at around 20°C.  
3
The temperature setting and the actual room temperature may  
vary somewhat depending on conditions.  
Press the  
(START/STOP) button. Heating operation starts  
START  
STOP  
with a beep. Press the button again to stop operation.  
I As the settings are stored in memory in the remote controller, you only  
have to press the (START/STOP) button next time.  
– 8 –  
DEHUMIDIFYING OPERATION  
Use the device for dehumidifying when the room temperature is over 16°C.  
When it is under 15°C, the dehumidifying function will not work.  
Press the FUNCTION selector so that the display indicates  
(DEHUMIDIFY).  
The FAN SPEED is set at LOW automatically.  
The FAN SPEED button does not work.  
1
2
Set the desired room temperature with the TEMPERATURE  
button (the display indicates the setting).  
°C  
The range of 20-26˚C is recommended as  
the room temperature for dehumidifying.  
START  
STOP  
Press the  
(START/STOP) button. Dehumidifying operation  
starts with a beep. Press the button again to stop operation.  
I As the settings are stored in memory in the remote controller, you  
only have to press the (START/STOP) button next time.  
I Dehumidifying Function  
When the room temperature is higher than the temperature setting: The device will dehumidify the room,  
reducing the room temperature to the preset level.  
When the room temperature is lower than the temperature setting: Dehumidifying will be performed at  
the temperature setting slightly lower than the current room temperature, regardless of the temperature  
setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature  
becomes lower than the setting temperature.  
– 9 –  
COOLING OPERATION  
Use the device for cooling when the outdoor temperature is 21-43°C.  
If humidity is very high (over 80°C) indoors, some dew may form on the air outlet grille of the indoor unit.  
Press the FUNCTION selector so that the display indicates  
(COOL).  
1
Set the desired FAN SPEED with the  
(the display indicates the setting).  
(FAN SPEED) button  
(AUTO): The FAN SPEED is HI at first and varies to  
MED or LOW automatically when the preset  
temperature has been reached.  
2
3
(HI)  
: Economical as the room will become cool  
quickly.  
(MED) : Quiet.  
(LOW) : More quiet.  
Set the desired room temperature with the TEMPERATURE  
button (the display indicates the setting).  
The range of 25-28°C is recommended as the  
room temperature for cooling.  
If the temperature setting is 27°C, the room  
temperature will be controlled at around 27°C.  
The temperature setting and the actual room temperature may  
vary somewhat depending on conditions.  
Press the  
(START/STOP) button. Cooling operation starts  
START  
STOP  
with a beep. Press the button again to stop operation. The  
cooling function does not start if the temperature setting is  
higher than the current room temperature (even though the  
(OPERATION) lamp lights). The cooling function will start as  
soon as you set the temperature below the current room  
temperature.  
I As the settings are stored in memory in the remote controller, you  
only have to press the (START/STOP) button next time.  
– 10 –  
FAN OPERATION  
You can use the device simply as an air circulator. Use this function to dry the interior of the indoor  
unit at the end of summer.  
Press the FUNCTION selector so that the display indicates  
(FAN).  
1
Press the  
(FAN SPEED) button.*  
2
Press the  
(START/STOP) button. Fan operation starts with  
START  
STOP  
RESET  
a beep. Press the button again to stop operation.  
.....  
FAN SPEED (AUTO)  
When the AUTO fan speed mode is set in the cooling/heating operation:  
G The fan speed will automatically change according to the temperature  
of discharged air.  
G When the difference of room temperature and setting temperature is  
large, fan starts to run at HI speed.  
For the heating operation  
G When the room temperature reaches setting temperature, fan speed  
changes to LOW automatically.  
G When the difference of room temperature and setting temperature is  
large, fan starts to run at HI speed.  
G After room temperature reaches the preset temperature, the cooling  
operation, which changes the fan speed and room temperature to obtain  
optimum conditions for natural healthful cooling will be performed.  
For the cooling operation  
– 11 –  
HOW TO SET THE TIMER  
Time, Day, Month  
1
Set the current month and  
day with the TIMER control  
button.  
TIME, DAY,  
MONTH  
(current time,  
day, month)  
After you change the  
batteries;  
M
D
M
D
OFF TIMER  
RESET  
ON TIMER  
RESERVE  
CANCEL  
OFF-Timer  
1
Press the  
button. The  
on the display.  
(OFF-TIMER)  
(OFF) mark blinks  
AM  
Start  
STOP  
You can set the device to turn off  
at the present time.  
ON-Timer  
1
Press the  
button the  
on the display.  
(ON-TIMER)  
(ON) mark blinks  
Stop  
Start  
G The device will turn on  
at the designated times.  
AM  
1
Press the  
button so that the  
mark blinks.  
(ON-OFF)  
(OFF)  
2
Set the turn-off time  
with the TIMER control  
button.  
3
Press the  
(ON-  
ON/OFF-Timer  
TIMER) button so that the  
(OFF) mark lights and  
the (ON) mark blinks.  
Start  
Stop  
Press the  
button.  
(RESERVE)  
G
G
G
The device will turn on (off) and off  
(on) at the designated times.  
The switching occurs first at the  
preset time that comes earlier.  
The arrow mark appearing on the  
display indicates the sequence of  
switching operations.  
PM  
PM  
PM  
AM  
How to Cancel Reservation  
Point the signal window of the remote controller toward the indoor unit, and press the  
button.  
(CANCEL)  
The (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit.  
NOTE  
You can set only one of the OFF-timer,  
ON-timer and ON/OFF-timer.  
– 12 –  
3
Set the current time with the  
TIMER control button.  
4
Press the  
The time indication starts lighting  
instead of flashing.  
(TIME) button again.  
2
Press the  
(TIME) button.  
G The time indication will disappear  
automatically in 10 second.  
G To check the current time setting,  
PM  
AM  
PM  
PM  
press the  
(TIME) button twice.  
The setting of the current time is  
now complete.  
Example: The current time is 1:30 p.m.  
3
Point the signal window of the remote controller toward the indoor unit, and  
press the (RESERVE) button.  
The (OFF) mark starts lighting instead of flashing and the sign  
2
Set the turn-off time with the  
TIMER control button.  
(RESERVED)  
(TIMER) lamp lights on the indoor unit.  
lights. A beep occurs and the  
PM  
PM  
Example: The device will turn off at 11:00p.m.  
The setting of turn-off time is now complete.  
2
Set the turn-on time with the  
TIMER control button.  
3
Point the signal window of the remote controller toward the indoor unit, and  
press the (RESERVE) button.  
The (ON) mark starts lighting instead of flashing and the  
(RESERVED) sign  
(TIMER) lamp lights on the indoor unit.  
lights. A beep occurs and the  
Example:  
AM  
The device will automatically turn on earlier so that the preset  
temperature can be reached at 7:00 a.m.  
AM  
The setting of the turn-on time is now complete.  
5
Point the signal window of the remote controller toward the indoor unit, and  
press the (RESERVE) button.  
The (ON) mark starts lighting instead of flashing and the  
4
Set the turn-on time with the  
TIMER control button.  
(RESERVED) sign  
(TIMER) lamp lights on the indoor unit.  
lights. A beep occurs and the  
PM  
PM  
Example:  
The device will turn off at 10:30 p.m. and then automatically  
turn on earlier so that the preset temperature can be reached  
at 7:00 a.m.  
AM  
The settings of the turn-on/off times are now complete.  
AM  
G The timer may be used in three ways: off-timer, on-timer, and ON/OFF (OFF/ON)-timer. Set  
the current time at first because it serves as a reference.  
G As the time settings are stored in memory in the remote controller, you only have to press  
the  
(RESERVE) button in order to use the same settings next time.  
13 –  
HOW TO SET THE SLEEP TIMER  
Set the current time at first if it is not set before (see the pages for setting  
the current time). Press the  
shown below.  
(SLEEP) button, and the display changes as  
Mode  
Sleep timer  
Indication  
4
4
4
4
1 hour  
2 hours  
3 hours  
7 hours  
H
1
Sleep timer off  
Sleep Timer: The device will continue working for the designated  
number of hours and then turn off.  
Point the signal window of the remote controller toward the indoor  
unit, and press the SLEEP button.  
SLEEP  
The timer information will be displayed on the remote controller.  
The TIMER lamp lights with a beep from the indoor unit. When the  
sleep timer has been set, the display indicates the turn-off time.  
Example: If you set 3 hours sleep  
time at 11:38 p.m., the turn-off  
time is 2:38 a.m.  
H
The device will be turned off by the sleep  
timer and turned on by on-timer.  
Sleep  
timer  
Start  
1
2
Set the ON-timer.  
Press the  
(SLEEP) button and set the sleep timer.  
Example:  
AM  
AM  
In this case, the device will turn off  
in 2 hours (at 1:38 a.m.) and turn  
on early so that the preset  
H
temperature will be almost reached  
at 6:00 next morning.  
How to Cancel Reservation  
Point the signal window of the remote controller toward the indoor unit, and press the  
button.  
(CANCEL)  
The (RESERVED) sign goes out with a beep and the  
(TIMER) lamp turns off on the indoor unit.  
14 –  
Explanation of the sleep timer  
The device will control the FAN SPEED and room temperature  
automatically so as to be quiet and good for peoples health.  
NOTE  
G If date or current time is not set, sleep timer can not be set.  
G If you set the sleep timer after the off-, on/off- or off/on-  
timer has been set, the sleep timer becomes effective instead  
of the off-, on/off- or off/on-timer set earlier.  
G You can not set other timer during sleep timer operation.  
G After sleep timer time is up and when press sleep button  
again, the sleep timer will be set as last setting.  
G Sleep timer effective only once.  
15 –  
ADJUSTING THE AIR DEFLECTOR  
Adjustment of the conditioned air in the upward and downward  
directions.  
1
The horizontal air deflector is automatically set to the proper  
angle suitable for each operation. The deflector can be swung  
up and down continuously and also set to the desired angle  
using the “  
(AUTO SWING)button.  
G If the “  
(AUTO SWING)button is pressed once,  
the horizontal air deflector swings up and down. If the  
button is pressed again, the deflector stops in its current  
position. Several seconds (about 6 seconds) may be  
required before the deflector starts to move.  
G Use the horizontal air deflector within the adjusting range  
shown on the right.  
G When the operation is stopped, the horizontal air deflector  
moves and stops at the position where the air outlet  
closes.  
Horizontal air deflector  
CAUTION  
G In Coolingoperation, do not keep the horizontal and  
vertical air deflector swinging for a long time. Some dew  
may form on the horizontal and vertical air deflector and  
dew may drop.  
Adjustment of the conditioned air in the left and right directions.  
2
G If the “  
(PARALLEL SWING)button is pressed  
once, the vertical air deflectors swing left and right to  
parallel. If the button is pressed again, the deflectors  
stop in their current position. Several second (about 6  
seconds) may be required before the deflectors start to  
move.  
G If the “  
(SYMMETRY SWING) button is pressed  
once, the vertical air deflectors swing left and right to  
symmetry. If the button is pressed again, the deflectors  
stop in their current position. Several seconds (about 6  
seconds) may be required before the deflectors start to  
move.  
G PARALLEL SWING  
PARALLEL  
SWING  
G SYMMETRY SWING  
SYMMETRY  
SWING  
16 –  
HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER  
Remove the cover as shown in the figure and take out the  
old batteries.  
1
Push and pull to the  
direction of arrow  
=
Install the new batteries.  
The direction of the batteries should match the marks in the  
case.  
2
CAUTION  
1. Do not use new and old batteries, or different kinds of batteries  
together.  
2. Take out the batteries when you do not use the remote  
controller for 2 or 3 months.  
17 –  
THE IDEAL WAYS OF OPERATION  
Suitable Room Temperature  
Install curtain or blinds  
Warning  
Freezing temperature  
is bad for health and a  
waste of electric power.  
It is possible to  
reduce heat  
entering the  
room through  
windows.  
Ventilation  
Effective Usage Of Timer  
At night, please use the sleep timer operation  
mode, together with your wake up time in the  
morning. This will enable you to enjoy a  
comfortable room temperature. Please use the  
timer effectively.  
Caution  
Do not close the room for a long period of  
time. Occasionally open the door and windows  
to allow the  
entrance of  
fresh air.  
Do Not Forget To Clean The Air Filter  
Please Adjust Suitable Temperature  
For Baby And Children  
Dusty air filter will reduce the air volume and  
the cooling efficiency. To prevent from wasting  
electric energy, please clean the filter every 2  
weeks.  
Please pay attention to the room temperature  
and air flow direction when operating the unit  
for baby, children and old folks who have  
difficulty in movement.  
18 –  
FOR USER’S INFORMATION  
The Air Conditioner And The Heat Source In The Room  
Caution  
If the amount of heat in the room is above the cooling  
capability of the air conditioner (for example: more  
people entering the room, using heating equipments  
and etc.), the preset room temperature cannot be  
achieved.  
Not Operating For A Long Time  
When the indoor unit is not to be used for a long  
period of time, please switch off the power from the  
mains. If the power from mains remains ON, the  
indoor unit still consumes about 8W in the operation  
control circuit even if it is in OFFmode.  
OFF  
When Lightning Occurs  
Warning  
To protect the whole unit during lightning, please  
stop operating the unit and remove the plug from the  
socket.  
UV-LED  
UV-LED will be ONwhen the START/STOP button is pressed. Light UV glare is visible when the UV-  
LED is ONand this is normal (not malfunction).  
Interference From Electrical Products  
Inverter-type  
fluorescent  
lamp.  
Caution  
To avoid noise interference, please place the indoor  
unit and its remote controller at least 1m away from  
electrical products.  
TV  
To prevent  
interference,  
place at least  
1m away.  
19 –  
ATTACHING THE AIR CLEANSING AND DEODORIZING FILTERS  
CAUTION  
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,  
stop operation and switch off the power supply.  
Open the front panel.  
G Pull up the front panel by holding it at both sides  
1
with both hands.  
Remove the filter.  
G Push upward to release the claws and pull out the  
2
filter.  
Attaching the air cleansing and deodorizing filters  
to the filter.  
G Attach the air cleansing and deodorizing filters to  
the frame by gently compress its both sides and  
release after insertion into filter frame.  
3
Claws  
(4 places)  
CAUTION  
Do not bend the air cleansing  
and deodorizing filter as it may  
cause damage to the structure.  
Attach the filters.  
G Attach the filters by ensuring that the surface written  
4
FRONTis facing front.  
G After attaching the filters, push the front panel at  
three arrow portion as shown in figure and close it.  
NOTE  
G In case of removing the air-cleansing & deodorizing filters, please follow the above procedures.  
G The cooling capacity is slightly weakened and the cooling speed becomes slower when the air-cleansing  
& deodorizing filters are used. So, set the fan speed to "HIGH" when using it in this condition.  
G Air-cleansing & deodorizing filters are not washable and can be use in 1 year time. Type number for  
this air cleansing filter is <SPX-CFH13>. Please use this number for ordering when you want it.  
G Do not operate the air conditioner without filter. Dust may enter the air conditioner and fault may occur.  
20 –  
MAINTENANCE  
CAUTION  
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,  
stop operation and switch off the power supply.  
1. AIR FILTER  
Clean the air filter, as it removes dust inside the room. In case the air filter is full of dust, the air flow  
will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean the  
filter following the procedure below.  
PROCEDURE  
Open the front panel and remove the filter  
G Gently lift and remove the air cleansing and  
1
deodorizing filter from the air filter frame.  
Vacuum dust from the air filter and air cleansing  
2
and deodorizing filter using vacuum cleaner. If  
there is too much dust, rinse under running tap  
water and gently brush it with soft bristle brush.  
Allow filters to dry in shade.  
G Re-insert the air cleansing and deodorizing  
3
filter to the filter frame. Set the filter with  
FRONTmark facing front, and slot them into  
the original state.  
G After attaching the filters, push the front panel  
at three arrow portions as shown in figure  
and close it.  
NOTE:  
G Air cleansing and deodorizing filter should be cleaned every month or sooner if noticeable loading  
occurs. When used overtime, it may loose its deodorizing function. For maximum performance, it is  
recommended to replace it every 3-6 months depending on application requirements.  
CAUTION  
G Do not wash with hot water at more than 40°C. The filter may shrink.  
G When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to  
the sun. The filter may shrink.  
G Do not use detergent on the air cleansing and deodorizing filter as some detergent may deteriorate  
the filter electrostatic performance.  
21 –  
Attaching the minus ion stick to the  
filter frame.  
G Put the minus ion stick to the lower  
hooks and install it so as to push up the  
upper hooks at the left side of front  
cover.  
Upper hook  
Minus ion stick  
Lower hook  
2. Washable Front Panel  
G Remove the front panel and wash with clean  
water.  
Wash it with a soft sponge.  
After using neutral detergent, wash thoroughly  
with clean water.  
G When front panel is not removed, wipe it with  
a soft dry cloth. Wipe the remote controller  
thoroughly with a soft dry cloth.  
G Wipe the water thoroughly.  
If water remains at indicators or signal  
receiver of indoor unit, it causes trouble.  
Method of removing the front panel.  
Be sure to hold the front panel with both hands  
to detach and attach it.  
Removing the Front Panel  
Attaching the Front Panel  
Flange  
Projection  
Hole  
G When the front panel is fully opened with  
both hands, push the right arm to the inside  
to release it, and while closing the front panel  
slightly, put it out forward.  
G Move the projections of the left and right  
arms into the Flanges in the unit and  
securely insert them into the holes.  
CAUTION  
G Do not splash or direct water to the body of the unit when cleaning  
it as this may cause short circuit.  
G Never use hot water (above 40°C), benzine, gasoline, acid, thinner or  
a brush, because they will damage the plastic surface and the coating.  
22 –  
CAUTION  
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,  
stop operation and switch off the power supply.  
3. MAINTENANCE AT BEGINNING OF LONG OFF PERIOD  
G Run the unit by setting the operation mode to  
(COOL), the temperature to 32°C and the fan speed  
to HI for about half a day on a fine day, and dry the  
whole of the unit.  
Air  
Blow  
G Switch off the power plug.  
Note :  
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly  
qualified persons in order to avoid a hazard.  
REGULAR INSPECTION  
PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONAL EITHER  
EVERY HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT OR SERVICE SHOP.  
Is the earth line disconnected or broken?  
1
Is the mounting frame seriously affected by rust and is the  
outdoor unit tilted or unstable?  
2
Is the plug of power line firmly plugged into the socket?  
(Please ensure no loose contact between them).  
3
Confirm  
23 –  
AFTER SALE SERVICE AND WARRANTY  
WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS.  
CONDITION  
CHECK THE FOLLOWING POINTS  
G Is the fuse all right?  
G Is the voltage extremely high or low?  
G Is the circuit breaker ON?  
When it does not operate  
G Was the air filter cleaned?  
G Does sunlight fall directly on the outdoor unit?  
G Is the air flow of the outdoor unit obstructed?  
G Are the doors or windows opened, or is there any source of  
heat in the room?  
When it does not cool well  
When it does not hot well  
G Is the set temperature suitable?  
Notes  
G In quiet operation or stopping the operation, the following phenomena  
may occassionally occur, but they are not abnormal for the operation.  
(1) Slight flowing noise of refrigerant in the refrigerating cycle.  
(2) Slight rubbing noise from the fan casing which is cooled and then  
gradually warmed as operation stops.  
G The odor will possibly be emitted from the room air conditioner because  
the various odor, emitted by smoke, foodstuffs, cosmetics and so on,  
sticks to it. So the air filter and the evaporator regularly must be cleaned  
to reduce the odor.  
G
G
Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above  
inspections. Inform your agent of the model of your unit, production number, date of installation. Please also  
inform him regarding the fault.  
Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the  
specified capacity.  
24 –  
Please note:  
On switching on the equipment, particularly when the room light is dimmed, a slight brightness fluctuation  
may occur. This is of no consequence.  
The conditions of the local Power Supply Companies are to be observed.  
Note  
G
Avoid to use the room air conditioner for cooling operation when the outside temperature is below  
21°C (70°F).  
The recommended maximum and minimum operating temperatures of the hot and cold sides  
should be as below:  
Cooling  
Heating  
Minimum  
Maximum  
Minimum  
Maximum  
Dry bulb °C  
Wet bulb °C  
Dry bulb °C  
Wet bulb °C  
21  
15  
21  
15  
32  
23  
43  
26  
20  
12  
2
27  
19  
21  
15  
Indoor  
Outdoor  
1
MEMO  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
25 –  
MEMO  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
.....................................................................................................................................................................................  
26 –  

ADTRAN 7000 Series User Manual
Carrier 38CKC User Manual
Fisher Price Fisher price J2457 User Manual
Fisher Price T4841 User Manual
Graco Baby Accessories PD213968B User Manual
Heat Controller Inc Air Conditioner EKTC User Manual
Hisense Group KFR 33GWE User Manual
Honeywell HERCULINE 2000 User Manual
HP Hewlett Packard LaserJet 4100mfp User Manual
HP Hewlett Packard MLP145 User Manual