GSC13  
Split SyStem Air Conditioner  
13 Seer / r-22  
to 5 tonS  
Contents  
Nomenclature....................................... 2  
Product Specifications .......................... 3  
Expanded Cooling Data ....................... 4  
AHRI Ratings ....................................... 18  
Dimensions ......................................... 18  
Wiring Diagram .................................. 19  
Accessories .......................................... 20  
Standard Features  
Cabinet Features  
Energy-efficient compressor  
Quiet condenser fan system  
Factory-installed liquid-line filter drier  
Copper tube/aluminum fin coil  
For use with R-22 refrigerant;  
charged with inert gas for shipping  
R-22 piston kit included  
Brass liquid and suction service  
valves with sweat connections  
Contactor with lug connections  
Ground lug connection  
Louver design sound control top  
Steel louver coil guard  
Heavy-gauge galvanized-steel cabinet  
Attractive Architectural Gray powder-paint  
finish with 500-hour salt-spray approval  
When properly anchored, meets the 2010  
Florida Building Code unit integrity  
requirements for hurricane-type winds  
(Anchor bracket kits available.)  
ETL Listed  
* Complete warranty details available from your  
SS-GSC13  
11/13  
Supersedes 9/13  
Product SPecificationS  
SpeCifiCAtionS  
GSC13  
0181G*  
GSC13  
0241F*  
GSC13  
0301E*  
GSC13  
0361G*  
GSC13  
0421C*  
GSC13  
0481C*  
GSC13  
0601D*  
Cooling Capacities  
Tonnage  
1½  
76  
2
2½  
72  
3
3½  
76  
4
5
Decibels  
76  
75  
76  
77  
Compressor  
RLA  
6.8  
40  
10.8  
56  
13.5  
68  
13.4  
74  
15.4  
87  
19.2  
112  
21.8  
137  
LRA  
Condenser Fan Motor  
Horsepower  
1/8  
1/8  
1/8  
0.7  
1/6  
1.1  
¼
¼
¼
FLA  
0.65  
0.65  
1.5  
1.5  
1.5  
Refrigeration System  
Refrigerant Line Size  
Liquid Line Size (“O.D.)  
Sucꢀon Line Size (“O.D.)  
Refrigerant Connecꢀon Size  
Liquid Valve Size (“O.D.)  
Sucꢀon Valve Size (“O.D.) ³  
Valve Type  
⅜"  
¾"  
⅜"  
¾"  
⅜"  
¾"  
⅜"  
⅞"  
⅜"  
⅜"  
⅜"  
1⅛"  
1⅛"  
1⅛"  
⅜"  
¾"  
⅜"  
¾"  
⅜"  
¾"  
⅜"  
¾" ³  
Sweat  
77  
⅜"  
¾" ³  
⅜"  
⅞" 4  
Sweat  
128  
⅜"  
⅞" 4  
Sweat  
118  
Sweat  
87  
Sweat  
77  
Sweat  
66  
Sweat  
108  
Refrigerant Charge  
Electrical Data  
AC Volts-Hz  
208-230/ 60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60  
Min. Circuit Ampacity¹  
Max. Overcurrent Device²  
Min / Max Volts  
Electrical Conduit Size  
Equipment Weight (lbs)  
Ship Weight (lbs)  
9.2  
15  
14.2  
25  
17.6  
30  
17.9  
30  
20.8  
35  
25.5  
40  
28.8  
50  
197/253  
½" or ¾"  
116  
197/253  
½" or ¾"  
116  
197/253  
½" or ¾"  
142  
197/253  
½" or ¾"  
141  
197/253  
½" or ¾"  
141  
197/253  
½" or ¾"  
176  
197/253  
½" or ¾"  
207  
130  
130  
159  
159  
159  
194  
225  
¹
Wire size should be determined in accordance with Naꢀonal Electrical Codes; extensive wire runs will require larger wire sizes  
²
³
Must use ꢀme-delay fuses or HACR-type circuit breakers of the same size as noted.  
Installer will need to supply ¾” to ⅞” adapters for sucꢀon line connecꢀons.  
Installer will need to supply ⅞” to 1⅛” adapters for sucꢀon line connecꢀons.  
Notes  
Always check the S&R plate for electrical data on the unit being installed.  
Charge with refrigerant charge listed on S&R plate; 15’ of ⅜” line included in this charge.  
System charge must be adjusted per Installaꢀon Instrucꢀons Final Charge Procedure.  
SS-GSC13  
3
Product SPecificationS  
expAnded rAtinGS — GSC130181G*  
4
SS-GSC13  
Product SPecificationS  
expAnded rAtinGS — GSC130181G* (Cont.)  
SS-GSC13  
5
Product SPecificationS  
expAnded rAtinGS — GSC130241f*  
6
SS-GSC13  
Product SPecificationS  
expAnded rAtinGS — GSC130241f* (Cont.)  
SS-GSC13  
7
Product SPecificationS  
expAnded rAtinGS — GSC130301**  
8
SS-GSC13  
Product SPecificationS  
expAnded rAtinGS — GSC130301** (Cont.)  
SS-GSC13  
9
Product SPecificationS  
expAnded CoolinG dAtA — GSC130361G*  
10  
SS-GSC13  
Product SPecificationS  
expAnded CoolinG dAtA — GSC130361G* (Cont.)  
SS-GSC13  
11  
Product SPecificationS  
expAnded rAtinGS — GSC130421C*  
12  
SS-GSC13  
Product SPecificationS  
expAnded rAtinGS — GSC130421C* (Cont.)  
SS-GSC13  
13  
Product SPecificationS  
expAnded rAtinGS — GSC130481C*  
14  
SS-GSC13  
Product SPecificationS  
expAnded rAtinGS — GSC130481C* (Cont.)  
SS-GSC13  
15  
Product SPecificationS  
expAnded rAtinGS — GSC130601d*  
16  
SS-GSC13  
Product SPecificationS  
expAnded rAtinGS — GSC130601d* (Cont.)  
SS-GSC13  
17  
Product SPecificationS  
AHRI RAtIngs  
Cooling Ratings  
Outdoor  
Unit  
Coil  
CFM  
AHRI #  
Total¹  
22,800  
27,600  
Sens.¹  
17,600  
21,000  
SEER²  
13  
EER³  
11  
GSC130241F*  
GSC130301(D,E)*  
GSC130481C*  
GSC130421C*  
GSC130363B*  
GSC130361G*  
GSC130601D*  
GSC130603C*  
GSC130483C*  
GSC130181G*  
GSC130484BD  
GSC130604BD  
CA*F1824*6B*+EEP  
CA*F3030*6B*+EEP  
CA*F4961*6A*+EEP  
CA*F4860*6B*+EEP  
CA*F3642*6C*+EEP  
CA*F3642*6C*+EEP  
CA*F4961*6A*+EEP  
CA*F4961*6A*+EEP  
CA*F4961*6A*+EEP  
CA*F1824*6B*+EEP  
CA*F4961*6A*+EEP  
CA*F4961*6A*+EEP  
800  
4700186  
4705227  
5528473  
5528472  
5528487  
5528471  
5528476  
5528477  
5528474  
5897360  
6468399  
6468400  
13  
11  
950  
44,500  
39,500  
33,400  
33,400  
53,000  
53,000  
44,500  
18,000  
44,500  
53,000  
33,800  
28,200  
24,200  
24,200  
38,000  
38,000  
33,800  
13,000  
33,800  
38,000  
13  
13  
13  
13  
13  
13  
13  
13  
13  
13  
11  
11  
11  
11  
11  
11  
11  
11  
11  
11  
1,600  
1,400  
1,200  
1,200  
1,600  
1,600  
1,600  
600  
1,600  
1,600  
¹
BTU/h  
²
³
Seasonal Energy Efficiency Raꢀo; tested and rated per AHRI 210/240  
Energy Efficiency Raꢀo @ 80 °F/67 °F Inside - 95 °F  
Notes  
Always check the S&R plate for electrical data on the unit being installed.  
When matching the outdoor unit to the indoor unit, use the piston supplied with the out-  
door unit or that specified on the piston kit chart supplied with the indoor unit.  
EEP: Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is  
not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling ꢀme delay.  
18  
SS-GSC13  
Product SPecificationS  
WIRIng DIAgRAm  
N L O Y R O C A T N T C O L E O P  
L E U B D O E T R E N A L T A  
SS-GSC13  
19  
Product SPecificationS  
DImensIons  
W
D
Dimensions  
Model  
H
W"  
26  
D"  
26  
H"  
GSC130181G*  
GSC130241F*  
GSC130301E*  
GSC130361G*  
GSC130421BC*  
GSC130481C*  
GSC130601D*  
27½  
25¾  
30¼  
30¼  
30¼  
36¼  
40  
23½  
26  
23½  
26  
29  
29  
29  
29  
29  
29  
29  
29  
AccessoRIes  
GSC13  
018**  
GSC13  
024**  
GSC13  
030**  
GSC13  
036**  
GSC13  
042**  
GSC13  
048**  
GSC13  
060**  
Model  
Description  
ABK-20  
ABK-21  
ASC-01  
CSR-U-1  
CSR-U-2  
CSR-U-3  
FSK01A  
LSK01A  
0263M00019  
OT18-60A  
Anchor Bracket Kit  
Anchor Bracket Kit  
X
X
X
X
X
X
X
X
X
X
X
Anꢀ-Short Cycle Kit  
Hard-start Kit  
X
X
X
X
X
X
X
X
X
X
X
Hard-start Kit  
Hard-start Kit  
Freeze Protecꢀon Kit 1  
Liquid Line Solenoid Kit 2  
Crankcase Heater  
Outdoor Thermostat  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Contains 20 brackets; four brackets needed to anchor unit to pad  
Installed on indoor coil  
¹
²
Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocaꢀng  
compressors require the use of start-assist components when used in conjuncꢀon with an indoor coil  
using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit.  
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without  
notice or without incurring obligations. © 2013 • Goodman Manufacturing Company, L.P. Houston, Texas • Printed in the USA.  
20  
SS-GSC13  

Briggs Stratton 460000 User Manual
Canon Printer H12 4608 User Manual
Carrier 48SS036 User Manual
Friedrich Air Conditioner 2004 User Manual
Friedrich Air Conditioner CP15 User Manual
Friedrich SQ10N10 User Manual
Heat Controller Inc Air Conditioner BG 101A User Manual
HoMedics MASSEUR IN A BOXTM RMM 300H 2EU User Manual
HP Hewlett Packard J3600 User Manual
HP Hewlett Packard LaserJet M1005 MFP User Manual