		 Residential & Light Commercial HVAC   
					Split System Air Conditioner   
					11⁄   
					208/230 Volt, 1-Phase, 60 Hz   
					2 
					thru 5 Tons   
					Performance:   
					Efficiency rating of 13 SEER and 14 SEER   
					Cooling capacities from 11⁄   
					to 5 tons   
					2 
					Refrigerant Circuit:   
					Factory installed liquid line filter drier   
					Long life copper tubes, aluminum fins   
					State-of-the-art compressors   
					Large, wrap-around coil surface   
					Quality Built:   
					Galvanized steel exterior cabinet with   
					1,000-hour salt spray, powder-coated finish   
					Powder-coated fan guard   
					Full louvered panel to protect coil   
					Formed base with 21⁄2" ground clearance   
					Limited 5-year warranty on parts   
					Easy To Install:   
					Factory-charged with R-22 refrigerant   
					Only three screws to access electrical controls   
					Easy access to service valves   
					Rated in Accordance with ARI Standard 210.   
					Certification Applies Only When Used with   
					Proper Components as Listed with ARI.   
					Additional rating information can be found   
					
					Model   
					Number   
					Size   
					(tons)   
					Nominal   
					BTUH   
					Min. Circuit   
					Ampacity   
					Max. Fuse or   
					Breaker   
					Operating Dimensions   
					H x W x D (inches)   
					Min. Mounting Ship / Operating   
					Pad Size (inches)   
					Weight (lbs)   
					144 / 138   
					142 / 136   
					169 / 163   
					189 / 180   
					213 / 204   
					217 / 208   
					230 / 220   
					1 
					1 
					1 
					1 
					C18ABD1VF   
					C24ABD1VF   
					C30ABD1VF   
					C36ACD1VF   
					C42ACD1VF   
					C48ACD1VF   
					C60ACD1VF   
					1 ⁄2   
					18,000   
					24,000   
					30,000   
					36,000   
					42,000   
					48,000   
					60,000   
					9.1   
					15   
					15   
					20   
					30   
					35   
					40   
					50   
					26 ⁄2 X 21 ⁄2 X 21 ⁄2   
					24 x 24   
					1 
					1 
					1 
					2 
					11.5   
					14.3   
					18.7   
					20.3   
					23.1   
					30.1   
					26 ⁄2 X 21 ⁄2 X 21 ⁄2   
					24 x 24   
					1 
					1 
					1 
					1 
					2 ⁄2   
					32 ⁄2 X 21 ⁄2 X 21 ⁄2   
					24 x 24   
					1 
					1 
					1 
					3 
					32 ⁄2 X 29 ⁄2 X 29 ⁄2   
					32 x 32   
					1 
					1 
					1 
					1 
					3 ⁄2   
					32 ⁄2 X 29 ⁄2 X 29 ⁄2   
					32 x 32   
					1 
					1 
					1 
					4 
					5 
					32 ⁄2 X 29 ⁄2 X 29 ⁄2   
					32 x 32   
					1 
					1 
					39 X 29 ⁄2 X 29 ⁄2   
					32 x 32   
				Product Specifications   
					ARI CERTIFIED COMBINATION PERFORMANCE RATINGS   
					Cooling Capacity (BTUH)   
					Factory   
					Supplied   
					Enhancement   
					UNIT   
					SIZE   
					Outdoor Unit   
					Indoor Unit   
					SEER1   
					EER   
					Total   
					Sensible   
					AC1A024A   
					AFPB24A1   
					TXV   
					17,500   
					17,500   
					18,000   
					21,600   
					21,600   
					21,600   
					21,600   
					26,600   
					26,600   
					26,600   
					28,000   
					28,000   
					34,000   
					34,000   
					35,000   
					35,000   
					40,000   
					40,000   
					41,500   
					44,000   
					44,000   
					53,000   
					53,000   
					12,750   
					12,750   
					13,500   
					15,750   
					15,750   
					17,000   
					17,000   
					19,500   
					19,500   
					19,500   
					21,000   
					21,000   
					24,750   
					24,750   
					25,500   
					25,500   
					29,250   
					29,250   
					31,000   
					32,250   
					32,250   
					38,750   
					38,750   
					13   
					13   
					14   
					13   
					13   
					14   
					14   
					13   
					13   
					13   
					14   
					14   
					13   
					13   
					14   
					14   
					13   
					13   
					14   
					13   
					13   
					13   
					13   
					11.3   
					11.3   
					12.0   
					11.3   
					11.3   
					12.2   
					12.2   
					11.4   
					11.4   
					11.4   
					12.0   
					12.0   
					11.4   
					11.4   
					11.8   
					11.8   
					11.5   
					11.5   
					12.0   
					11.5   
					11.5   
					11.5   
					11.5   
					18   
					24   
					C18ABD1VF   
					TXV/TDR   
					TXV/TDR   
					TXV   
					AC1A036 + FV80A070-4   
					AC1A024A   
					AFPB24A1   
					TXV/TDR   
					TXV/TDR   
					TXV/TDR   
					TXV   
					C24ABD1VF   
					C30ABD1VF   
					AC1A042A + FV80A070-4   
					AC1A042A + FV80A085-4   
					AC1A030A   
					AC1A036A   
					TXV   
					30   
					AFPB36A1   
					TXV/TDR   
					TXV/TDR   
					TXV/TDR   
					TXV   
					AC1A060A + FV80A085-4   
					AC1A060A + FV80A115-5   
					AC1A036A   
					AFPB36A1   
					TXV/TDR   
					TXV/TDR   
					TXV/TDR   
					TXV   
					36   
					42   
					C36ACD1VF   
					C42ACD1VF   
					AC1A060A + FV80A085-4   
					AC1A060A + FV80A115-4   
					AC1A042A   
					AFPC48A1   
					TXV/TDR   
					TXV/TDR   
					TXV   
					AC1A060A + FV80A115-5   
					AC1A060A   
					48   
					60   
					C48ACD1VF   
					C60ACD1VF   
					AFPC48A1   
					TXV/TDR   
					TXV   
					AC1A060A   
					AFPC60A1   
					TXV/TDR   
					1. TDR required to obtain SEER rating   
					Notes:   
					a. Fedders coils include factory installed TXV. Fedders gas furnaces and air handlers   
					contain the TDR as standard equipment.   
					b. TDR kit available as accessory. Part Number TDR001A.   
					c. Tested outdoor and indoor combinations have been tested in accordance with   
					DOE test procedures for central air conditioners.   
					d. Above ratings based on 80ºF (27ºC) DB and 67ºF (19ºC) WB indoor entering   
					air temperature and 95ºF (35ºC) DB air entering outdoor unit.   
					EER   
					- 
					- 
					- 
					- 
					Energy Efficiency Ratio   
					Seasonal Energy Efficiency Ratio   
					Time-Delay Relay   
					SEER   
					TDR   
					TXV   
					Thermostatic Expansion Valve   
					3 
					Specifications subject to change without notice.   
				Product Specifications   
					LINE SET LENGTH AND SIZE   
					SUCTION LINE SIZES   
					LIQUID LINE SIZES   
					25 ft. 50 ft.   
					3/8" 3/8"   
					BTUH   
					15 ft.   
					3/4"   
					3/4"   
					7/8"   
					7/8"   
					7/8"   
					7/8"   
					1 1/8"   
					25 ft.   
					3/4"   
					3/4"   
					7/8"   
					7/8"   
					7/8"   
					7/8"   
					1 1/8"   
					50 ft.   
					3/4"   
					3/4"   
					7/8"   
					7/8"   
					7/8"   
					7/8"   
					1 1/8"   
					75 ft.   
					3/4"   
					15 ft.   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					1/2"   
					75 ft.   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					1/2"   
					18   
					24   
					30   
					36   
					42   
					48   
					60   
					3/4"   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					1/2"   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					3/8"   
					1/2"   
					7/8"   
					7/8"   
					1 1/8"   
					1 1/8"   
					1 1/8"   
					Recommended liquid and suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and   
					15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied   
					by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet   
					vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.)   
					Note: See unit installation instructions for proper installation.   
					EXTENDED COOLING CAPACITIES   
					RATINGS AT   
					CONDENSER ENTERING AIR TEMPERATURE DEGREES (F)   
					OUTDOOR   
					UNIT MODEL   
					STANDARD CONDITIONS   
					INDOOR UNIT   
					BTUH SEER*   
					CFM   
					80   
					85   
					90   
					95   
					100   
					105   
					110   
					115   
					TOTAL   
					SENSIBLE 13,900 13,550 13,150 12,750 12,250 11,800 11,300 10,850   
					TOTAL 19,700 19,100 18,600 18,000 17,400 16,900 16,300 15,800   
					SENSIBLE 14,300 14,000 13,800 13,500 13,200 12,900 12,500 12,100   
					TOTAL 23,700 22,900 22,150 21,600 20,700 19,950 19,150 18,400   
					SENSIBLE 17,300 16,750 16,200 15,750 15,100 14,550 14,000 13,500   
					TOTAL 24,000 23,200 22,400 21,600 20,600 19,800 19,000 18,200   
					SENSIBLE 17,900 17,600 17,300 17,000 16,600 16,300 16,000 15,700   
					TOTAL 29,150 28,300 27,500 26,600 25,650 24,750 23,850 23,000   
					SENSIBLE 21,300 20,750 20,100 19,500 18,750 18,100 17,500 16,800   
					TOTAL 31,000 30,000 29,000 28,000 27,000 26,000 25,000 24,200   
					SENSIBLE 22,200 21,800 21,400 21,000 20,600 20,200 19,800 19,400   
					TOTAL 37,000 36,200 35,150 34,000 32.900 31,800 30,700 29,650   
					SENSIBLE 27,000 26,450 25,650 24,750 24,000 23,250 22,500 21,650   
					TOTAL 39,000 37,600 36,400 35,000 34,000 33,000 31,800 30,600   
					SENSIBLE 27,200 26,600 26,200 25,500 25,000 24,600 24,200 23,600   
					TOTAL 43,450 42,300 41,150 40,000 38,800 37,650 36,550 35,500   
					SENSIBLE 31,750 30,850 30,100 29,250 28,350 27,500 26,700 25,950   
					TOTAL 47,650 46,400 45,250 44,000 42,700 41,550 40,330 39,200   
					SENSIBLE 34,750 33,850 33,100 32,250 31,200 30,500 29,400 28,650   
					TOTAL 56,600 55,400 54,150 53,000 51,800 50,600 49,500 48,600   
					19,100 18,550 18,025 17,500 16,800 16,150 15,550 14,850   
					AC1A024A   
					17,500   
					18,000   
					21,600   
					21,600   
					26,600   
					28,000   
					34,000   
					35,000   
					40,000   
					44,000   
					53,000   
					13   
					14   
					13   
					14   
					13   
					14   
					13   
					14   
					13   
					13   
					13   
					650   
					C18ABD1VF   
					C24ABD1VF   
					C30ABD1VF   
					C36ACD1VF   
					AC1A036A + FV80A070-4   
					AC1A024A   
					640   
					810   
					AC1A042A + FV80A070-4 /   
					AC1A042A + FV80A085-4   
					810   
					AC1A030A   
					1,000   
					1,000   
					1,150   
					1,150   
					1,350   
					1,550   
					1,750   
					AC1A060A + FV80A085-4 /   
					AC1A060A + FV80A115-5   
					AC1A036A   
					AC1A060A + FV80A085-4 /   
					AC1A060A + FV80A115-5   
					C42ACD1VF   
					C48ACD1VF   
					C60ACD1VF   
					AC1A042A   
					AC1A048A   
					AC1A060A   
					SENSIBLE 41,250 40,500 39,550 38,750 37,850 36,950 36,150 35,500   
					*TDR required to obtain SEER rating.   
					4 
					Specifications subject to change without notice.   
				Product Specifications   
					5 
					Specifications subject to change without notice.   
				Product Specifications   
					Residential & Light Commercial   
					AC Condensing Units   
					Model Number Identification   
					C 24 A B D 1 V F * A   
					Product Type   
					C = Air Conditioner   
					CH = Heat Pump   
					Brand   
					Fitting Type   
					V = Sweat   
					Nominal Capacity   
					18 = 18,000 BTUH [5.28 kW]   
					24 = 24,000 BTUH [7.03 kW]   
					30 = 30,000 BTUH [8.79 kW]   
					36 = 36,000 BTUH [10.55 kW]   
					42 = 42,000 BTUH [12.31 kW]   
					48 = 48,000 BTUH [14.07 kW]   
					60 = 60,000 BTUH [17.58 kW]   
					Electrical Designation   
					1 = 208 / 230 Volts, 1 Phase, 60 Hz   
					2 = 220 Volts, 1 Phase, 50 Hz   
					3 = 208 / 230 Volts, 3 Phase, 60 Hz   
					4 = 460 Volts, 3 Phase, 60 Hz   
					5 = 230 Volts, 3 Phase, 50 Hz   
					6 = 380 Volts, 3 Phase, 50 Hz   
					Series   
					Chassis Size   
					Refrigerant Variations   
					D = R-22 Refrigerant   
					B = 211⁄2" W x 211⁄2" D x H - Determined by BTU Size   
					C = 291⁄2" W x 291⁄2" D x H - Determined by BTU Size   
					Fedders Corporation   
					505 Martinsville Rd.   
					Liberty Corner, NJ 07938   
					(908) 604-8686   
					All product specifications reflect available information at the printing of this brochure.   
					Fedders reserves the right to revise or modify products and/or specifications without notice.   
					©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.   
					FD-071 0507   
					Form No. F-C13   
				 |