Daewoo DPB 280LH User Manual

Service Manual  
FLOOR STANDING AIR CONDITIONER  
Model: DPB-280LH  
DAEWOO ELECTRONICS CO., LTD.  
OVERSEAS SERVICE DEFT.  
1. INSTALLATION GUIDE  
1
IN STALLATIO N P LACE  
NIndoor unit  
NOutdoor unit  
• Flat and strong place in the room  
• No obstacles in front of air in/out grille  
• A place no reach of direct ray of sun (if necessary, shield the  
light)  
• Easy place to connect drain hose to outside of room  
• Easy place to connect copper tube with outdoor unit  
• No obstacles in front of air in/out grille  
• A place having a drain out-let  
• Secure enough distance from neighboring objects as • Easy place to connect copper tube with indoor unit  
shown below.  
• Secure enough distance from neighboring objects as shown  
below.  
• Secure enough distance from neighboring objects as  
shown below.  
CAUTION : Do not hang the outdoor unit on the wall of building, in case of falling, it may cause a serious trouble and damage.  
2
SPACE TO IN STALL  
Secure enough space from the neighboring objects as shown below.  
This is required to operate the unit efficiently.  
10cm  
50cm  
5cm  
(Indoor unit)  
(Outdoor unit)  
NNSpecifica tion a nd method of copper tube  
Connection method of copper tube is to make connection with flare nut at the end of the copper tube with a flare tool.  
Flare specification  
Unit: mm  
A
B
Nominal diameter  
B
Lquid  
Gas  
3/8”  
5/8”  
12~12.4  
18.6~19  
9.52  
15.88  
Torque  
Unit: mm  
Torque  
Lquid  
Gas  
3/8”  
5/8”  
300Kg cm  
500Kg cm  
2
IN STALLATIO N O F IN DO O R UN IT  
3
1) Drain hose should maintain downward slope to outside of room.  
2
2) Indoor unit should be fixed firmly with the bracket to avoid falling down.  
The bracket has several holes to fix the unit any direction needed  
(fore/back/right/left)  
1
IN STALLATIO N O F O UTDO O R UN IT  
4
5
1) Cushion rubbers absorb vibration of outdoor unit  
2) The unit must be grounded for safety in accordance with local  
electrical codes. (Grounding resistance should be under 100 ohms)  
2
1
REFRIG ERAN T TUBE CO N N ECTIO N  
IDU TERMINAL BLOCK  
CAUTION  
Use designated diameter and thickness of tube.  
Connect all tube as short as possible and fix firmly.  
Less than 3M of the difference of height between indoor  
and outdoor unit is desirable.  
3
2
1
Y
N
L
Fill up more refrigerant if the connection tube is longer  
than 5M (50g/M).  
(The refrigerant volume filled from the factory is suitable  
for 5M connection)  
Be careful not to let in any dust or motes into the tube  
when the tube passes the wall.  
3
2
1
Y
N
L
When insulating the connection, use foam rubber or  
equivalent.  
ODU TERMINAL BLOCK  
(Connecting method)  
3
Spec  
Color  
BLUE  
3
2
1.25mm2  
1.25mm2  
1.25mm2  
1.25mm2  
1.25mm2  
1.25mm2  
1.25mm2  
2.0mm2  
SIGNAL LINE  
SIGNAL LINE  
BLACK  
1
RED  
SIGNAL LINE  
Y
N
BROWN  
SIGNAL LINE  
BROWN  
MAIN POWER (INDOOR)  
MAIN POWER (INDOOR)  
MAIN POWER (INDOOR)  
MAIN POWER (OUTDOOR)  
MAIN POWER (OUTDOOR)  
MAIN POWER (OUTDOOR)  
YEL/GRN  
RED(or BLUE)  
BLACK  
L
N
2.0mm2  
2.0mm2  
YEL/GRN  
WHITE  
L
(Specification of harness)  
6
ELECTRICAL W IRIN G  
CAUTION  
Be sure to use designated wires and make it as short as possible  
Use an exclusive power supply for the air conditioner  
Use an electricity leakage interrupter having suitable capacity.  
Grounding resistance should be under 100 ohms and the grounding wire should be connected firmly to the  
terminal of out door unit.  
NNWire connection of indoor and outdoor unit  
When connecting wires of indoor and outdoor unit, the numbers of terminal block and terminals of connecting wires should  
match exactly as shown below.  
Terminals of connecting wires should be fixed firmly using wire fixing tool to the same direction of terminal board.  
(Diagram of wire connection)  
4
2. SPECIFICATIONS  
NDPB-280LH  
MODEL  
DPB-280LH  
ITEM  
Function  
Class  
COOLING  
HEATING  
T
Power  
220~240V/ 50Hz  
Capacity  
W
Btu/h  
l/h  
8,200  
28,000  
-
8,200  
28,000  
-
Dehumidification  
Running Current  
Power Input  
Starting Current  
Type  
A
14  
14  
Electrical  
Data  
W
2,800  
2,800  
A
-
Scroll  
Compressor  
Model  
ZR36K3-PFJ-501  
50µF/370V AC  
Capacitor  
Indoor Unit  
Sirocco  
Outdoor Unit  
Propeller fan  
8µF/370V AC  
A2935BA010  
Type  
Fan  
Capacitor  
5µF/400V AC  
DE112  
Motor Model Number  
Control  
Capillary  
2,000  
Refrigerant  
(R-22)  
Charge Q'ty  
Type  
g
Flare  
Connection  
OD (Liquid/Suction)  
in(mm)  
mm  
3/8(9.52mm)  
500 x 1,830 x 350  
40  
5/8(15.88mm)  
872 x 675 x 325  
66  
Dimensions (W x H x D)  
Net Weight  
kg  
5
3. OUTLINE  
IN DO O R UN IT  
1
NDPB-2 8 0 LH  
4
5
3
2
7
6
1
No  
1
Part Name  
Quantity  
Description  
Remarks  
Connecting Hole  
Evaporator  
3
1
1
1
1
1
1
ø60X100 (Left, Right, Back)  
Heat Exchanger  
Air Inlet  
2
3
Suction Grille  
Discharge Grille  
Fan Blower  
4
Air outlet  
5
Sirocco Type  
6
Joint (Gas)  
OD ø15.88mm  
OD ø9.52mm  
7
Joint (Liquid)  
6
O UTDO O R UN IT  
2
NDPB-2 8 0 LH  
No  
1
Part Name  
Quantity  
Description  
Remarks  
Service Valve (Liquid)  
Service Valve (Gas)  
Service Door  
Fan Guard  
1
1
1
1
1
1
1
1
1
1
OD ø9.52mm Flare Type  
OD ø15.88mm Flare Type  
2
3
4
Fan Protector  
5
Fan Blower  
Propeller type  
6
Condenser  
Heat Exchanger  
Foor propeller fan  
Depend on Models  
Ground  
7
Fan motor  
8
Compressor  
9
Earth Bolt  
10  
Connection Hole  
Power & Control wire  
7
4. OPERATION  
1
PARTS O F N AM E AN D FUN CTIO N  
Indoor Unit  
AIR OUT  
- According to the operation mode, it  
is opened/closed automatically.  
MAIN CONTROLS/  
REMOTE SENSOR  
AIR IN  
- It is to suck warm air.  
- There is an air filter inside this grille.  
The method to open the air suction  
grille  
Pull the upper side of grille with  
both hands.  
LCD REMOTE CONTROLLER  
- Operative distance is within 7m from  
the indoor unit.  
- Use toward to the remote sensor  
8
ROOM TEMPERATURE / DESIRED TEMPERATURE INDICATOR  
- It displays current room temperature and desired room temperature.  
FAN MODE INDICATOR  
AUTO FAN SPEED INDICATOR  
FAN SPEED INDICATOR  
AUTO MODE INDICATOR  
TIMER/SLEEP INDICATOR  
COOL MODE INDICATOR  
QUICK MODE  
INDICATOR  
ECONOMY MODE  
INDICATOR  
MODE BUTTON  
HEAT MODE  
INDICATOR  
(ONLY HEAT PUMP  
MODEL)  
ON/OFF BUTTON  
- Whenever you push this button.  
It repeats on -> off -> on -> off.  
MILD MODE INDICATOR  
ECONOMY MODE BUTTON  
DEHUMIDIFIER MODE  
INDICATOR  
FAN SPEED BUTTON  
- AUTO -> LOW -> MIDDLE ->  
HIGH -> NATURAL  
TEMPERATURE BUTTONS  
- Each time you push  
- Each time you push  
this button, temperature  
this button, temperature  
goes up by 1˚C.  
falls by 1˚C.  
9
Outdoor Unit  
OUTDOOR UNIT AIR OUT  
SERVICE VALVES(GAS TUBE)  
SERVICE VALVES(LIQUID TUBE)  
CAUTION  
Do not install the outdoor unit on  
unstable place like outside wall of  
building or outside of balcony. In case  
of falling, it may cause serious trouble  
and damage.  
OUTDOOR UNIT AIR IN  
- If there is any obstacle in front  
of the grille, the efficiency of  
the unit can be lowered.  
10  
2
REM O TE CO N TRO LLER  
Na m e of Ea ch Button  
AUTO  
Display  
Displays information  
pertaining to unit.  
ON/OFF Button  
Press to turn the unit  
on or off.  
TEMPERATURE Buttons  
Press to raise or lower  
the desired temperature.  
FAN SPEED Button  
Press to select the fan speed  
(Auto, High " ", Middle " ",  
Low " ", Natural).  
FAN DIR.  
Button  
MODE  
SLEEP  
FAN SPEED  
FAN DIR.  
Press to select up/down  
direction for fan.  
MODE Button  
FAN DIR.  
TIMER  
FAN DIR.  
Button  
Press to cycle through the modes  
(Auto/Quick/Cool/Fan/Dehumidifier/  
Heat)  
Press to select left/right  
direction for fan.  
ON/OFF  
ENTER/  
TURBO/MILD  
CANCEL  
TURBO/MILD  
Press to be more silent and  
comfortable room condition  
SLEEP Button  
Press to set the unit for  
the sleep mode.  
TIMER ON/OFF Button  
Press to set the unit off or on time.  
(0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8,  
10, 12, 16, 20, 24hr)  
TIMER ENTER/CANCEL Button  
Press to enter a timer setting or  
to cancel timer setting  
COVER  
Slide down to access most  
of the remote buttons.  
Slide down further to  
access the battery  
compartment.  
11  
3
REM O TE CO N TRO LLER DISP LAY  
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)  
Lights to indicate the mode selected.  
AUTO  
FAN Indicators  
Lights to indicate  
the fan speed.  
FAN DIRECTION Indicators  
Lights to indicate the  
fan direction.  
NATURAL Indicator  
Lights to indicate the  
speeds simulating a breeze.  
TIMER Indicators  
Lights to indicate the timer function mode.  
TEMPERATURE & RESERVATION TIME lndicator  
Lights to indicate the temperature or time.  
Repla cing Ba tteries  
TIMER  
Slide down the cover to  
access most of the  
remote buttons. Slide  
down further to access  
the battery compart-  
ment.  
Insert two AAAsize  
Alkaline batteries  
following the polarity  
diagram below.  
ON/OFF  
ENTER/  
CANCEL  
TURBO/MILD  
2
1
+
+
12  
4
DESCRIP TIO N O F FUN CTIO N S  
OFF-Tim er  
If you set time in OFF-Timer Mode, the unit will stop at the set time.  
Unit ON  
ON  
Unit OFF  
OFF  
SET Time  
HOUR  
ON-Tim er  
If you set time in ON-Timer Mode, the unit will run at the set time.  
Unit ON  
ON  
Unit OFF  
OFF  
SET Time  
HOUR  
Control of Room Tem pera ture  
(1) Range of setting temperature: 18~32°C  
(2) Setting temperature: Operating temperature of compressor  
COMP (ON)  
COMP (ON)  
COMP (OFF)  
COMP (OFF)  
-1°C  
°
+1˚C  
(RT-DT)  
-1°C  
+1˚C  
(DT-RT)  
(COOLING)  
(HEATING)  
*RT: ROOM TEMPERATURE  
DT: DESIRED TEMPERATURE  
(3) During the time of test operating, Fan (Indoor, Outdoor) and Compressor is running regardless of room  
temperature.  
Buzzer  
If the Indoor Unit Display receive the signal of Remote Controller, you can hear the signal "beep " or "beep,  
beep".  
(1) In the case of receiving ON/OFF signal-beep” “beep”  
(2) And so on-beep”  
13  
Fa n Speed (Indoor Unit)  
(1) Motor speed (high speed, middle speed, low speed).  
(2) Remote controller setting fan speed. (Auto, L, M, H, Natural)  
(3) Relation of operating mode between fan speed. (legned: X-no relation)  
DEHUMI-  
FAN ONLY  
COOL  
AUTO  
QUICK  
HEAT  
DIFICATION  
H
H
H
L
L
H
H
H
H
M
M
M
M
M
L
L
L
L
L
L
H
H
L
Auto  
X
Auto  
Auto  
Auto  
Natural  
Natural  
Natural  
L
Natural  
H
Natural  
(4) Automatic Operation  
If the unit is set in 'AUTO' mode, the unit operates automatically according to the room temperature to keep the  
room temperature comfortable.  
(COOLING)  
H
M
L
0°C  
1°C  
2°C  
(RT-DT)  
(HEATING)  
H
M
L
0°C  
1°C  
2°C  
3°C  
(DT-RT)  
14  
Sleep Mode  
(1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature.  
(The unit will not operate after 4 hour)  
(2) For changing the temperature.  
DT  
DT  
+0.5°C  
+0.5°C  
0.5°C  
+0.5°C  
0.5°C  
0.5°C  
0
0.5  
1.0  
HOUR  
0
0.5  
1.0  
HOUR  
(COOLING CYCLE)  
(HEATING CYCLE)  
(3) To cancel sleep mode, press the SLEEP button again or press the MODE button once.: the SLEEP  
indicator will disappear in the display.  
Frost Prevention of Indoor Unit  
When the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coil  
temperature is lower than -2°C at the end of 10 minutes of continuous compressor operation from the start, the  
microcomputer of the unit stops the compressor to protect the unit from the frost. The control procedure for  
indoor coil freeze protection.  
1) The compressor and outdoor fan turn off.  
2) Indoor fan operates according to user set speed.  
3) The normal operation returns when the indoor coil  
ON  
Compressor and  
OFF  
temperature is higher than 7°C or equal to 7°C.  
Outdoor Fan  
-2°C  
7°C  
(Indoor coil temperature)  
15  
3 m in. Tim e Dela y of Com pressor  
In normal operation, there is a time delay of three minutes between turn off and turning back on including initial  
3 Seconds Tim e Dela y of Indoor Fa n Motor  
When the speed of indoor fan motor changes, there is a time delay of 3 seconds at each speed step.  
Auto Mode  
(1) In Auto Mode  
After the indoor fan is operated for 20 seconds in the Auto Mode, the unit will operate automatically by selecting  
operating Mode according to the room temperature  
RT: Room temperature  
DT: Desired  
(
)
ROOM TEMPERATURE  
OPERATING MODE  
<
DT+3˚C RT  
Cooling  
<
<
DT-2˚C  
RT DT+2˚C  
Dehumidifier  
Heating  
>
DT -2°C RT  
(2) Selecting Operating Mode Again  
Room temperature meets desired temperature and the compressor stops running over 30 minutes, then the unit  
selects operating Mode again.  
16  
Dehum idifica tion Mode  
1DT+1˚C < RT  
Outdoor Fan, Compressor : ON  
Indoor Fan : Low speed  
<
<
2DT-1˚C RT DT+1˚C  
Outdoor Fan, Compressor : 3 min/ON, 5 min/OFF  
Indoor Fan : Low speed  
3DT-1˚C > RT  
Outdoor Fan, Compressor : OFF  
Indoor Fan : Low speed  
Air Discha rge Direction  
1. Press fan direction button to select fan direction  
Press desired fan direction button, "UP DOWN" or "LEFT RIGHT" control louver moves, press  
again to stop  
FAN DIR.  
FAN DIR.  
Quick Mode(Pow erful Cooling & Hea ting)  
(1) Cooling Mode  
(1) Heating Mode  
* When the room temperature is higher than 22˚C or  
equal to 22˚C  
* When the room temperature is lower than 22˚C  
1Fan Speed: high speed (Fixed)  
1Fan Speed: high speed (Fixed)  
2Air discharge direction: The control is available.  
3Set temperature: 18°C (Fixed)  
2Air discharge direction: The control is available.  
3Set temperature: 32°C (Fixed)  
Self-Dia gnostic Function  
The control will contain diagnostic test to verify the integrity of the system.  
(1) Error Code Display : RT (Room Temperature) LED  
ERROR CODE  
DISPLAY  
E2”  
ERROR CONTENTS  
Indoor unit sensor open or short  
Outdoor unit sensor open or short  
1
2
E2”  
Compressor, Electrical parts of  
comp. Gas leak  
3
E3 ”  
17  
5. CIRCUIT DIAGRAM  
1
W IRE CO N N ECTIO N O F IN DO O R AN D O UTDO O R UN IT  
NNDPB-2 8 0 LH  
18  
M AIN ELECTRIC PARTS  
2
NNDPB-2 8 0 LH  
Object/part No.  
Motor-compressor  
Outdoor fan motor  
Indoor fan motor  
Manufacturer/trademark  
Copeland  
Type/model  
ZR36K3-PFJ  
Technical data  
AC220-240V 50Hz R22  
AC 230V 50Hz  
AC 230V 50Hz  
AC 250V  
Standard  
Mark(s) of confirmity  
DEMKO  
DMI  
A2935BA010  
DE112  
NONE  
O-YANG  
NONE  
Thermal protector for Korea Taxas  
17AM035A5  
fan motor  
Instruments  
Jaeil engineering  
ST-16  
AC 220-240V 50/60Hz  
AC 220-240V 50/60Hz  
VDE  
Synchronous motor  
Namyang Precision NYM-16H-1  
(Alter)  
NONE  
Stepping motor  
Hyup jin precision  
Samwha capacitor  
Samwha capacitor  
Donglim  
MSFCC20F02  
37H08500B  
PEB-958  
DC 12V  
NONE  
Dual capacitor for  
compressor and  
outdoor fan motor  
8/50µF 370VAC  
5µF 400VAC  
TUV, UL, CSA  
TUV, UL, CSA  
Running capacitor  
for indoor fan motor  
Terminal block  
Transformer  
DTB-8P  
AC 300V 25A  
AC 220V/18VDC 50/60Hz  
AC 220-240V 50Hz  
AC 220V 40W  
AC 220-240V 25A  
AC 250V 5A  
NONE  
NEMKO  
NONE  
NONE  
VDE  
Namsung electronics DWA-5401FN  
Reversing valve  
Ranco japan  
V26110D  
Compressor heater Young chang  
AC Control realy  
Relay  
Omron electronics  
G7L-2A-TUB  
Chung won electronics CS11-12H  
TUV, UL, CSA  
VDE  
Fuse  
Triad electronics  
Pilkor electronics  
50T  
AC 250V 3.15A  
AC 275V  
X2 capacitor  
Photocoupler  
Varistor  
PCX2 335  
VDE, N.S.  
VDE  
Toshiba electronics TLP560J  
AC 250V  
Marcon electronics  
TNR15G561K  
504-616V 50A  
600V 3A  
UL  
Triac  
Toshiba electronics SM3JZ47  
UL  
19  
3
P CB CIRCUIT DIAG RAM  
20  
NO  
1
Part Code  
3108803400  
5FVLB3152L  
3107000600  
3108802500  
3108802600  
3108802700  
3108802900  
3108803000  
3108801900  
3108801910  
3108802000  
3108804100  
3108802200  
D15G561K--  
DZN4004A--  
CCXE1H102Z  
CCXE1H103M  
CCXE1E104M  
CDXE1H104M  
CEXE35338M  
CEXE1V108C  
CEXE1E477C  
CEXE1C106C  
CEXE1C475C  
CN4XD104M  
RN-4K1272F  
RD-4K103J-  
RD-4K842F-  
RD-4K562J-  
RD-4K102J-  
RD-4K301J-  
RD-4K101J-  
Part Name  
PIN  
Quantity  
Specification  
GP881206-2(187)  
3
1
2
1
1
1
1
1
1
1
1
1
1
1
6
1
1
8
1
1
1
1
1
1
1
2
10  
2
2
3
4
1
2
FUSE  
250V 50T 3.15A  
AFC-520  
3
FUSE CLIP  
WAFER  
4
YW396-03AVD  
YW396-03AVD (RD)  
YW396-03AVD (BK)  
YW396-05AVD  
YW500-02V  
5
WAFER  
6
WAFER  
7
WAFER  
8
WAFER  
9
WAFER  
SMW250-04  
SMW250-04(RD)  
SMW250-06  
SMW250-07  
SMW250-10 (RD)  
15G561K  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
WAFER  
WAFER  
WAFER  
WAFER  
VARISTOR  
DIODE  
1N4004 TAPE  
102Z,50VDC  
103Z,50VDC  
104Z,25VDC  
104Z,CR0561B-Z5U  
3300uF 35V SD  
1000uF 35V SD  
470uF 25V SD  
10uF 50V SS  
4.7uF 50V SS  
F4 104Z  
C-CERA  
C-CERA  
C-CERA  
C-MULTI  
C-ELEC  
C-ELEC  
C-ELEC  
C-ELEC  
C-ELEC  
CAPA. ARRAY  
RESISTOR  
RESISTOR  
RESISTOR  
RESISTOR  
RESISTOR  
RESISTOR  
RESISTOR  
1/4W-12.7KF  
1/4W-10KJ  
1/4W-8.4KF  
1/4W-5.6KJ  
1/4W-1KJ  
1/4W-300J  
1/4W-100J  
21  
NO  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
Part Code  
RD-2K200J-  
RD-2K390J-  
RD-2K121J-  
RD-2K102J-  
CLV-B3104M  
4EFR-37071  
3105796100  
3106002900  
3105698200  
52C131J003  
3109400100  
3109400100  
3104398700  
5SC0101128  
1KA7812AP-  
1KA7805AP-  
TKRC102M--  
1KA7042P--  
4850103610  
TSM3JZ47--  
1TLP560J--  
13GS87PH46  
13GT4051B-  
13GT62004A  
13GT62783A  
Part Name  
RESISTOR  
RESISTOR  
RESISTOR  
RESISTOR  
C-LINE ACROSS  
SNUBBER  
HEAT SHINK  
WASHER  
Quantity  
Specification  
1
2
5
1
1
1
1
1
1
1
32  
1
1
5
1
1
2
1
1
1
1
1
1
2
1
1/2W-20J  
1/2W-39J  
1/2W-150J  
1/2W-1KJ  
275V 104K  
0.1UF 120 300V  
33(H)X23X17  
HEAT SINKøÎ  
DP-2520BA  
130uH 3A  
BUZZER  
COIL  
JUMPER  
10mm  
JUMPER OPTION  
PCB MAIN  
RELAY  
10mm  
162X169  
CS11-SH12  
KIA7812P  
IC REGULATOR  
IC REGULATOR  
TR  
KIA7805P  
KRC102M  
KIA7042P  
IC RESET  
RESONATOR  
TRIAC  
CST8.00MGW  
SM3JZ47  
PHOTO COUPLER  
IC MICOM  
IC MUX  
TLP560J  
TMP87C846AN  
TC4051BP  
TD62004AP  
TD62783AP  
IC DRIVE  
IC DRIVE  
22  
4
P CB DRIVIN G DESCRIP TIO N  
Pow er Supply(1 )  
12V  
5V  
CL1  
VAR  
D2  
AC 220V  
D1  
D4  
IC2  
275V  
104K  
IC3  
7812  
7805  
CC2  
CE2  
+
CC3  
CE3  
FUSE1  
3.15A  
CC1  
CE1  
+
VI VO  
VI VO  
+
D3  
104  
16V  
100µF  
25V  
470µF  
35V  
1000µF  
104  
104  
POWER TRANS  
DESCRIPTIO N  
DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac Driving  
Photo Triac, Buzzer Driving, Stepping Motor. AC voltage of secondary Power Transformer is rectified by Bridge  
Diode, and it is filtering by Main Condensor CE1.  
Filtered DC voltage is about +18V, is regulated +12V DC by Regulator IC7812.  
And it is regulated +5V DC by Regulator IC7805.  
VAR is serge filter and CC1, CC2, CC3 is Noise filter.  
Oscilla tor(2 )  
5V  
19  
CC13  
104  
OSC  
8M  
20  
DESCRIPTIO N  
Oscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency.  
Ocillatory wave is as following Fig 2-1.  
VDD-10%  
VSS+10%  
Fig 2-1  
23  
Sensor(3 )  
Room temperature and Evaporator temperature Sensor Input  
5V  
CN10  
EVA  
R32  
330  
1
2
3
4
5
1
23  
MICOM  
PT-K43C  
Room  
R37  
12.7K  
CA1  
104  
MUX  
SMW250-04  
R31  
330  
PT-K43C  
R38  
12.7K  
CA1  
104  
DESCRIPTIO N  
Number 23 of Micom is Terminal of A/D convertor Input.  
Room temperature and Evaporator temperature is sensing by change of Thermister Resistance, Micom is put  
in 5V by ratio between R37 (12.7K) and R38 (12.7K).  
Relation between temperature and voltage is following Table 3-1.  
CA1 is Noise filter.  
Resistance & Voltage of the Sensor  
temp(°C) resistance1() Vout(V)  
temp(°C) resistance1() Vout(V)  
temp(°C) resistance1() Vout(V)  
10  
9  
8  
7  
6  
5  
4  
3  
2  
1  
0
1
2
3
4
5
6
7
8
54,769  
52,070  
49,579  
47,272  
44,116  
42,190  
40,390  
37,902  
36,368  
34,235  
32,279  
31,064  
29,358  
27,781  
26,794  
25,400  
24,101  
22,888  
21,752  
20,687  
19,685  
19,050  
18,143  
17,286  
16,476  
15,708  
14,979  
0.941  
0.980  
1.020  
1.059  
1.118  
1.157  
1.196  
1.255  
1.294  
1.353  
1.412  
1.451  
1.510  
1.569  
1.608  
1.667  
1.725  
1.784  
1.843  
1.902  
1.961  
2.000  
2.059  
2.118  
2.176  
2.235  
2.294  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
14,288  
13,629  
13,002  
12,405  
12,021  
11,468  
10,939  
10,432  
9,947  
9,634  
9,182  
8,890  
8,467  
8,060  
7,79,  
7,415  
7,168  
6,809  
6,577  
6,239  
6,020  
5,806  
5,597  
5,392  
5,094  
4,901  
4,711  
2.353  
2.412  
2.471  
2.529  
2.569  
2.627  
2.686  
2.745  
2.804  
2.843  
2.902  
2.941  
3.000  
3.059  
3.095  
3.157  
3.196  
3.255  
3.294  
3.353  
3.392  
3.431  
3.471  
3.510  
3.569  
3.608  
3.647  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
4,526  
4,435  
4,255  
4,080  
3,908  
3,739  
3,656  
3,493  
3,332  
3,253  
3,098  
3,021  
2,870  
2,795  
2,721  
2,576  
2,504  
2,433  
2,363  
2,293  
2,156  
2,088  
2,020  
1,954  
1,888  
1,822  
1,758  
3.686  
3.706  
3.745  
3.784  
3.824  
3.863  
3.882  
3.922  
3.961  
3.980  
4.020  
4.039  
4.078  
4.098  
4.118  
4.157  
4.176  
4.196  
4.216  
4.235  
4.275  
4.294  
4.314  
4.333  
4.353  
4.373  
4.392  
9
10  
11  
12  
13  
14  
15  
16  
24  
Tria c Driving(4 )  
12V  
N
L
L1  
AC 220V  
1
2
TLP561  
PT1  
1
2
130µH  
3A  
SN1  
MICOM  
0.1µF  
T1  
SM3JZ47  
120Ohm  
IC4  
KID 65004  
R2  
TO MOTOR  
7
10  
32  
1K  
1/2W  
DESCRIPTIO N  
Number 32 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is supplied  
Trigger Signal.  
Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Time  
delay part according to Fan Speed. (Ref. Fig 4-1) SN1 is Snubber.  
AC220V  
TRIGGER  
LOW SPEED  
MI  
D
D
L
E
S
P
E
E
D
HIGH SPEED  
MOTOR  
INPUT  
Fig 4-1  
25  
Rem ote Controller(5 )  
DESCRIPTIO N  
Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gotten  
fid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1.  
But in Secondary Wave Custom Code is Reversed Face.  
9ms  
4.5ms  
16bit  
24bit  
8bit  
16bit  
0.56ms  
1.69ms  
0.56ms  
1.12ms  
bit 0  
2.25ms  
bit 1  
CUSTOM  
CODE  
DATA  
CODE  
CHECK  
SUM  
LEADER CODE  
TAILER  
Fig 5-2  
BIT STRUCTURE  
Fig 5-1  
26  
Micom Pow er Supply(7 )  
5V  
VDD 42  
+
CE4  
10µF  
16V  
CC5  
104  
41  
40  
MICOM  
39  
OSC  
8MHz  
19  
20  
21  
CC7  
104  
VSS  
22  
DESCRIPTIO N  
MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Using Oscillator, CC7 is noise filter.  
27  
Reset(8 )  
5V  
R4  
5.6K  
IC6  
7042P  
+
CE5  
4.7µF  
50V  
MICOM  
18  
DESCRIPTIO N  
Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect  
Power ON and Voltage less than 4.25V, and then send Reset Signal.  
Vcc (+5V)  
4.25V  
t
DELAY TIME  
FOR POWER ON  
H
RESET  
L
t
POWER  
ON  
28  
Function Selecting(9 )  
R22  
R23  
R24  
R25  
JS1  
JS2  
JS3  
JS4  
27  
26  
25  
24  
MICOM  
DESCRIPTIO N  
Selecting function is as following table 9-1.  
* When power source is put at first, Funtion selection input is recognized.  
And when the unit is running the microcomputer ignore variation of funtion selection input.  
SHORT  
SIMPLE  
132  
OPEN  
LCD  
JS1  
JS2  
JS3  
JS4  
180  
MILD  
HIGH  
Heat Pump  
Cooling Only  
Table 9-1  
Buzzer Driving(1 0 )  
VCC  
12V  
DESCRIPTIO N  
MICOM  
R7  
1K  
BZ  
Micom 34 Terminal put out Buzzer Driving Pulse,  
its output is driving Buzzer through Buffer.  
Ocillatory Frequency of buzzer is selected by  
internal Micom.  
KID 65004  
6
11  
34  
This unit is setting at 2KHz.  
29  
Zero Crossing Detect(1 1 )  
VCC  
R5  
10K  
TR2  
KRC102M  
R6  
1K  
D5  
MICOM  
1
2
1
31  
TRANS  
OUTPUT  
R3  
5.6K  
CC8  
103  
D6  
2
1
DESCRIPTIO N  
It detect Zero Cross part of Trans output voltage, Transistor TR2 is used to put in the Micom.  
Detail Driving is as following Fig 11-1.  
AC18V  
The  
Number  
31 of  
H
Micom  
terminal  
L
DETECT POINT  
Fig 11-1  
30  
Stepping Motor Driving(1 2 )  
12V  
CN11  
1
2
3
IC4  
+
B
9
Ø 1  
M1  
10  
Ø 2 FOR SWING  
4
MICOM  
11  
12  
5
6
Ø 3  
Ø 4  
KID65004  
DESCRIPTIO N  
There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.  
It is driving as following Fig 12-1. (Ring Count Method of 8 Status)  
Ø 4  
Ø 3  
Ø 2  
Ø 1  
(Normal Rotating)  
(Reversed Rotating)  
Fig 12-1  
31  
MICOM  
Display Output  
1 P77(HSO)  
2 P76(HSCK)  
3 P75(SO)  
4 P74(SI)  
5 P73(SCK)  
6 P72(PDO/PWM)  
7 P71(INT4)  
8 P70(INT3/TC3)  
9 P07  
VDD 42  
(XTOUT)P22 41 Key Input  
(XTIN)P21 40  
(INT5/STOP)P20 39  
P17 38 Compressor Heater Driving  
P16 37  
(TC2)P15 36  
(PPG)P14 35 Outdoor Unit Motor Driving  
(DVO)P13 34 Buzzer Driving  
(INT2/TC1)P12 33 Remocon Input  
(INT1)P11 32 Indoor Unit Motor Driving  
(INTO)P10 31 Zero Crossing Detect  
(AIN7)P67 30 Display Driving  
(AIN6)P66 29  
Stepping Motor  
10 P06  
11 P05  
12 P04  
13 P03  
Compressor Relay Driving  
14 P02  
15 P01  
(AIN5)P65 28  
Auto Swing Driving  
4-way Valve Driving  
16 P00  
(AIN4)P64 27 Fuction Select  
(AIN3)P63 26  
17 TEST  
18 RESET  
19 XIN  
(AIN2)P62 25  
Reset Circuit  
Oscillation  
(AIN1)P61 24  
20 XOUT  
21 (VASS)VSS  
(AIN0)P60 23 Temperature Sensor Input  
VAREF 22  
32  
DARLINGTON ARRAYS (KID65004)  
IN1 1  
IN2 2  
IN 3 3  
IN 4 4  
IN5 5  
IN6 6  
IN7 7  
GND 8  
16 OUT 1  
15 OUT 2  
14 OUT 3  
13 OUT 4  
12 OUT 5  
11 OUT 6  
10 OUT 7  
COMMON  
OUTPUT  
INPUT  
10.5K  
7.2K‰  
GND  
9 COMMON FREE  
WHEELING DIODES  
VOLTAGE REGULATOR (KIA7805AP-5VDC)  
SCHEMATIC DIAGRAM  
INPUT  
100  
100  
10K  
100K  
500  
240  
0.3  
200  
3.3  
K
OUTPUT  
1
2
3
2K  
6K  
0.19K  
1.4  
2.7  
K
30pF  
28K  
1K  
K
Fin 2 is ground  
for Cose 221A.  
Case is ground  
for Case 1.  
5K  
500  
6K  
5K  
GND  
VOLTAGE REGULATOR (KIA7812AP-12VDC)  
INPUT  
10K  
10K  
210  
16K  
100  
300  
200  
36K  
64K  
300  
50K  
012  
520  
50  
200  
40  
pF  
OUTPUT  
60K  
26K  
29K  
20K  
Pin 1. INPUT  
2. GROUND  
3. OUTPUT  
20K  
GND  
(Equivalent Ciircuit)  
33  
RESET IC (KIA 7042P)  
1
3
VCC  
OUT  
KIA70  
42P  
2
GND  
INPUT  
OUTLINE  
GROUND  
OUTPUT  
34  
6. REFRIGERANT CYCLE  
INDOOR UNIT  
OUTDOOR UNIT  
HIGH PRESSURE SWITCH  
INDOOR  
HEAT EXCHANGER  
M
UNION  
SERVICE VALVE  
FAN  
M
FILTER  
DISTRIBUTER  
OUTDOOR  
HEAT EXCHANGER  
COMPRESSOR  
CAPILLARY TUBE  
Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter.  
Model Name  
Cooling  
Heating  
Contents  
Capillary tube(  
×L×  
)
IDØ1.4 x 1000mm(6.0l/min) x 5EA  
ODØ2.0 x 250mm  
Charge Quantity  
2000 g  
35  
Trouble  
Is the  
unit display  
normal?  
Is the power  
applied to the  
unit  
NO  
Check power supply mains  
or interconnection wires  
YES  
YES  
Outdoor unit does  
not run?(note. 1)  
NO  
Is the  
power normal?  
check the voltage between  
L & N of terminal  
block  
NO  
Check the wiring of indoor  
YES  
Does  
the compressor run  
normally?  
NO  
YES  
press the power ON/OFF  
button on remote controller  
YES  
YES  
NO  
Indoor unit does  
not run(note 1)  
NO  
Is the unit  
display  
mormal?  
YES  
Does the  
beeper beep two  
times?  
Normal  
Does  
control PCB  
Check the failure  
code according to  
the self diagnostic  
(note 2)  
NO  
status LED repeat one  
second "on and  
off"?  
NO  
YES  
check the  
connecting  
point of  
magnetic  
contactor  
YES  
control PCB fault  
Micom or reset  
IC fault  
NO  
Is the display  
all off?  
YES  
YES  
check the failure  
code according to  
the self-diagonostic  
(note 2)  
Check the connector on display  
PCB connected to control PCB  
Check the display PCB itself  
Check the remote signal receiver  
Check the connection between signal  
receiver and control PCB  
1
Neither Indoor Unit nor Outdoor Unit Runs  
The power is applied to the unit  
Rating voltage  
Check the  
Breaker or Fuse  
under 90%  
L
Check the voltage between  
and  
N
of terminal block  
Rating voltage more than 90%  
No  
No  
Check the indoor unit display  
is the display all off?  
Self Diagnostic  
function is ON  
Yes  
Yes  
Press the ON/OFF switch of  
Remote Control  
No  
Check according to  
self Diagnostic function  
Is the indoor unit display all off?  
Control P.C.B defect  
Pull out the power plug  
and then insert the power plug  
after 5 second  
Control P.C.B is normal  
Recheck from the beginning  
37  
2
Outdoor Unit Runs but Indoor Unit Do Not Run  
Check rotation of indoor fan  
NO  
Check the Fan Motor  
bearing and fan  
Rotate indoor fan by hand  
YES  
Check the power P.C.B.  
The circuit for triac control  
Rating voltage  
under 90%  
Check input Voltage of Fan  
Motor connector at power P.C.B  
Rating Voltage more than 90%  
Open or short  
Check the winding resistance of  
Indoor unit fan motor  
Change of fan motor  
Normal  
Check the fan motor capacitor  
Check the connecting wire of  
indoor fan motor  
Run again  
38  
3
Outdoor Fa n Do Not Run  
Rating voltage  
L
Check the voltage between  
and  
Check the  
N
of outdoor unit terminal  
connecting wire  
under 90%  
Check the wiring  
and voltage  
Rating voltage  
under 90%  
L
Check the voltage between  
and  
and  
N
of indoor unit terminal  
within doors  
Rating voltage  
under 90%  
Check the  
connecting wire  
L
Check the voltage between  
2
of outdoor unit terminal  
Check outdoor fan motor individually  
39  
4
Only Com pressor Do not Run  
- Check the following at cooling mode  
Check the voltage between  
Check the connecting  
wire between indoor  
and outdoor.  
Rating voltage  
less than 90%  
N
and  
Y
of outdoor unit terminal  
Rating voltage more than 90%  
Check the control P.C.B  
the circuit for relay  
driving.  
Rating voltage  
less than 90%  
N
Check the voltage between  
and  
Y
of indoor unit terminal  
Rating voltage more than 90%  
Check the magnetic contactor  
Check the wiring of outdoor unit  
NG  
Change the magnetic  
contactor.  
Check the compressor  
(Check the winding resistance)  
Open or Short  
Change the  
compressor.  
OK  
Check the compressor capacitor  
40  
5
REMO TE CO NTRO LLER ASSMBLY FUNCTIO NAL TEST METHO D  
TEST START  
No  
Power supply again  
Power Supply  
No  
Is Display at the  
beginning ON?  
Select ON/OFF button  
Check the Following  
BATTERY SPRING  
MICOM  
PCB  
Yes  
No  
Is Display at the  
beginning ON?  
LCD  
Select Mode button  
No  
ERROR  
Is it normal?  
Select FAN SPEED button  
No  
Is it normal?  
ERROR  
L
Select FAN DIR. button  
(
)
LL  
No  
ERROR  
ERROR  
Is it normal?  
No  
Is display at the  
begining ON?  
(Whenever you selectted Temp.  
Button, it is changed by 1°C (18~32°C)  
Select TEMP. Button (,)  
Is it normal?  
No  
ERROR  
Select ON/OFF button  
41  
No  
No  
No  
No  
ERROR  
ERROR  
ERROR  
ERROR  
Is LCD display OFF?  
Select TIMER ON Button  
Is it normal  
Select Timer Enter Button  
display?  
TIMER  
Select CANCEL Button  
Is all display OFF?  
Select ON/OFF Button  
Select OFF (Timer) Button  
(0.5~24 HOUR)  
No  
ERROR  
ERROR  
ERROR  
Is it normal?  
Select SLEEP Button  
No  
No  
SLEEP MODE  
Display ON?  
Select SLEEP Button  
Is display at the  
beginning ON?  
TEST OK!  
42  
8. EXPLODED DIAGRAM  
1
INDOOR UNIT  
NO  
1
Part Code  
3100090100  
3100042301  
3100602801  
3108008600  
3101501900  
3106600210  
3106903100  
3100025000  
3105200300  
3100301600  
3101501100  
3100503901  
3104398800  
5EPK560120  
3100042501  
3100042603  
3100042802  
3100042903  
3105100400  
3102707930  
3101402700  
3100048310  
3100043000  
3107000400  
3100087200  
3104202700  
3105501800  
3104301010  
3103401510  
3103401610  
3100090620  
3100604700  
Part Name  
ASSY CABNET BODY  
BASE MOTOR ASSY  
BRACKET PAN DRAIN  
MOTOR IDU  
Quantity  
Remarks  
1
1
1
1
3
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
3
4
5
CUSHION MOTOR  
SCROLL HOUSING  
CAPACITOR MOTOR IDU  
BLOWER ASSY  
6
7
8
9
WASHER STOPPER  
BASE  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
CUSHION BASE  
BOX CONTROL  
ASSY MAIN PCB  
TRANS  
PAN DRAIN ASSY  
EVAPORATOR ASSY  
PIPE DISCHARGE ASSY  
PIPE SUCTION ASSY  
SPRING SENSOR  
HARNESS COIL SENSOR  
COVER EVAP. L  
ASSY COVER EVAP. R  
COVER EVAP. TOP ASSY  
CLIP THERMO  
COVER HOUSING ASSY  
PANEL CONTROL  
WINDOW  
ASSY CONTROL PCB  
KNOB SELECTION  
KNOB POWER  
ASSY PANEL FRONT  
BRACKET FRONT L  
44  
NO  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
Part Code  
3100604800  
3102201600  
310P40086E  
3108005300  
3101101300  
3100702100  
3106501430  
3106501530  
3107801000  
3107802200  
3106700100  
3106301100  
3106503000  
3101203400  
3101408000  
3100090200  
3102403720  
3102500901  
3102501001  
3107900100  
3104504700  
3100056510  
3108912340  
Part Name  
BRACKET FRONT R  
Quantity  
Remarks  
1
1
1
1
1
1
5
1
1
1
1
1
6
2
1
1
1
1
1
4
8
1
1
FRAME DISCHARGE  
SWING MOTOR ASSY  
MOTOR STEPPING  
CASE MOTOR  
BUSHING MOTOR  
BLADE HORIZONTAL 1  
BLADE HORIZONTAL 2  
LINK GUIDE R  
LINK M  
CAM  
BAR VERTICAL  
BLADE VERTICAL  
PUSH MOUNT TIE  
COVER BOX CONTROL  
ASSY COVER TOP  
GRILLE SUCTION  
GUIDE FILTER L  
GUIDE FILTER R  
MAGNET  
PLATE MAGNET  
FILTER AIR ASSY  
TERMINAL BLOCK  
45  
2
OUTDOOR UNIT  
NO  
1
Part Code  
3100041704  
3107103000  
3107103200  
7400208411  
7392801211  
3102800300  
3100031223  
3102402100  
3100041100  
3100041201  
3105401300  
3105401200  
3106002300  
3100086810  
3100079310  
3101407900  
3100031702  
3104201601  
3108912340  
5SC0202700  
3109508000  
3105300400  
3108008500  
3101802001  
3100031400  
3100031500  
3100041400  
3102102000  
3101402500  
Part Name  
BASE PAN PAINT ASSY  
COMPRESSOR ASSY  
CUSHION COMP  
Quantity  
Remarks  
1
1
4
4
4
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
3
4
WASHER PLAIN  
5
NUT LOCK  
6
CRANKCASE HEATER  
CONDENSER ASSY  
GRILLE COND  
7
8
9
GUIDE POST P/T ASSY  
BRK SERVICE P/TAS  
SERVICE VALVE G  
SERVICE VALVE L  
BOLT HEX  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
PIPE REVERSING ASSY  
PIPE FILTER ASSY  
COMP COVER  
PLT PARTITION ASSY  
PANEL CONTROL  
TERMINAL BLOCK  
POWER RELAY  
CAPACITOR DUAL  
SUPPORT MOTOR  
MOTOR ODU  
FAN PROPELLER  
CABINET FRONT P/T AS  
CABINET SIDE P/T AS  
PANEL TOP ASSY  
GRILLE DISCHARGE  
COVER SERVICE  
47  
DAEWOO ELECTRONICS CO., LTD.  
686, AHYEON-DONG MAPO-GU SEOUL, KOREA  
C.P.O. BOX 8003 SEOUL, KOREA  
TELEX: DWELEC K28177-8  
CABLE: DAEWOOELEC”  
FAX: 02) 360-8184  
TEL: 02) 360-8182/8178~9  
PRINTED DATE: APR.1999  

Blue Sea Systems Battery Charger PN7520 User Manual
Briggs Stratton 6B SF User Manual
Briggs Stratton Automobile Parts 110000 User Manual
Brother Printer MFC J432W User Manual
Carrier 38AK User Manual
Dell All in One Printer 924 User Manual
Fisher Price V4341 User Manual
Hisense Group KFR 25GWE User Manual
Honda Automobiles Backup Sensors 4622040M User Manual
HP Hewlett Packard HP LASERJET 3150 User Manual