1.888.830.1326
Table of Contents
Congratulations on purchasing
What to Expect with
Your Installation
Tools Needed
Mounting Options
Ceiling Bracket
your new Hunter® ceiling fan! It will
provide comfort and performance
in your home or office for many
years. This installation and operation
manual contains complete
instructions for installing and
operating your fan.
2
3
7
4
5
We are proud of our work and
appreciate the opportunity to
supply you with the best ceiling fan
available anywhere in the world.
Preparation
Downrod
Wiring
Canopy
To register your fan, please visit:
Save your receipt for proof of purchase.
6
10
16
11
Maintenance
& Cleaning
Blades
Switch Housing
Light Kit
Troubleshooting
?
?
?
12
13
14
17
1
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Tools Needed
Pliers
Wire Strippers
Screwdrivers
Ladder
9/64” Drill Bit
(optional)
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
O
34
CEILING
1.888.830.1326
Mounting Options
If you have a flat ceiling:
Hang your fan by a standard downrod (included).
Standard
Mounting
Support
Structure
Support
Structure
If you have an angled ceiling:
Ceiling
Outlet Box
(required)
1. You will need a longer downrod (sold separately).
Angled
Mounting
2. If your ceiling angle is greater than 34°, you will
also need an Angled Mounting Kit (sold separately).
Ceiling
Outlet Box
(required)
Standard
Mounting
Style
Angled
Mounting
Style
Use the three steps below to determine if your ceiling angle is greater than 34°
1
2
3
34°
PLACE
SLIDE
toward ceiling
FOLD
against wall
on dotted line
Guide Touches
BOTH Ceiling & Wall
Guide Touches
but NOT Ceiling
Wall
Use Standard Mounting
or Low-Profile Mounting
Use Angled Mounting
to hang the fan from a
to hang the fan from a flat ceiling.
vaulted or angled ceiling.
You need BOTH
a Longer
You need ONLY
a Longer
Downrod &
an Angled
Downrod
Mounting Kit
*most common
4
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Ceiling Bracket
For angled ceilings, point
opening toward peak.
OFF
Use wood screws
(included) when securing
to support structure with
Use machine screws
(provided with outlet
box) when securing to
Make sure all four (4) bumpers
If you are unable to do this,
call Technical Support at
1-888-830-1326.
are still attached.
approved electrical outlet existing ceiling fan-rated
box. Drill 9/64” pilot holes
in support structure to aid
outlet box. Make sure
it is securely installed
in securing ceiling bracket and is acceptable for fan
with hardware found in support of 31.8 kg (70 lbs)
the
hardware bag.
or less.
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
Refer to warning w.1 on pg. 2
5
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Preparation
Ceiling Bracket (continued)
Time Saver Tip: Get a helper
to insert grommets, found in
the hardware bag, into the
blades while you’re doing the
next couple of steps.
Remove the shipping blocks from the
motor. Save the screws. They will be
needed for blade iron installation.
Note: Some fans will have a shipping
ring instead of shipping blocks. Please
remove the ring and save the screws.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Downrod
Standard
skip to next page
Downrod
for ceilings 8-10’ high
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Longer
Downrod
for angled
ceilings or
ceilings 10’ or
higher
1
2
3
4
5
Shorter
Downrod
for fans installed
close to ceiling
10
9
8
7
6
Steps 6-10 to reassemble with new pipe
7
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Downrod (continued)
Remove the pre-installed
setscrew so that the downrod
can be inserted.
The wires can be cut, but
leave at least 8” extending
from the top of the downrod.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
8”
3/8”
If the setscrew is not tightened
securely, the fan may fall.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Downrod (continued)
Put the wires and downrod through the
canopy. Let the canopy sit loosely on top
of the fan.
DO NOT PICK THE FAN UP BY THE
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Wiring
Note: To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then twist
clockwise until tight.
M
I
N
O
R
G
F
For Dual Switches
Using the orange wire
connectors from
Green/Yellow
Stripe
the
hardware bag,
connect the white wire
(grounded) from the
For a Single Switch
Using the orange wire
connectors from
ceiling to the white wire
from the fan.
Using an orange wire
connector from
the
hardware bag, connect
Connect the black wire
(ungrounded) from the
ceiling to the black wire
from the fan. Connect the
second (ungrounded) wire
from the ceiling to the blue
wire from the fan.
the
hardware bag,
connect the 3 grounding
wires (green, green/
yellow stripe, or bare
copper) coming from the
ceiling, downrod, and
hanging bracket.
the black wire (ungrounded)
from the ceiling to the black
and the blue wires from the
fan. Connect the white wire
(grounded) from the ceiling to
the white wire from the fan.
F
N
A
O
M
M
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
10
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Canopy
Screw
Holes
Position the canopy so that, when
lifted into place, the canopy fits into
Lift the canopy into place so that
the screw holes are aligned.
Insert the two canopy screws
found in the
hardware bag.
the hanging bracket as shown.
Note: Fan style may vary.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Blades
Remember the screws that
you kept after removing the
shipping blocks (page 6)? You
need them plus five more from
the hardware bag for this step.
Insert grommets found in the
hardware
Lightly attach the blade irons to the
motor with screws found in
bag into the holes in the blades, then
secure each blade to a blade iron with
the
hardware bag, then securely
screws found in the
hardware bag.
tighten after both screws are attached.
Your blades are shielded with Dust Armor® which
is a nanotechnology coating that repels dust. For
cleaning the fan, use soft brushes or cloths to prevent
scratching. Cleaning agents may damage the finishes.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Switch Housing
Feed the wire plug through the center
hole of the upper switch housing, then
wrap keyhole slots around the screws and
twist counterclockwise.
Screw two (2) housing assembly screws
from the hardware bag halfway into
the motor housing. It does not matter
which two screw holes you choose.
Insert the third screw, found in
hardware bag, into place and then
tighten all three (3) screws.
the
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
housing fixture falling.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Light Kit
Screw
Holes
Install the three switch housing screws
found in the hardware bag.
Lift the lower switch housing up until its
screw holes are aligned with the screw holes
in the upper switch housing.
Connect the plugs from the upper and
lower switch housings. Make sure to line up
the colored markings on the connectors.
Make sure the lower switch housing is securely attached to
the upper switch housing. Failure to properly secure all three
assembly screws could result in the light fixture falling.
Want to install your fan without a light kit?
“How do I install my fan without the light kit?”
14
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Light Kit (continued)
Fan
Pull
Chain
Metal
Plate
Light
Pull
Chain
Globe
Globe
Keeper
Finial
Cap
Finial
Press the globe and globe keeper
flush against the metal plate. Thread
the light pull chain through the hole
in the center of the finial cap and
thread the fan pull chain through the
hole in the side of the cap. Finally,
thread only the light pull chain
Connect the appropriate pull
chain pendant to each of the short
chains coming from the finial
and finial cap. The fan pull chain
controls the speed: from high to
off. The light pull chain controls
the light fixture: on and off.
Install a bulb into each of
the sockets. When necessary,
replace with bulbs of the same
type and wattage.
See next page for fan
operation instructions.
through the hole in the finial and
screw the finial onto the threaded rod.
Note: In compliance with US federal energy regulations, this ceiling fan
contains a device that restricts its light output. Exceeding the wattage
limit marked on the MAX wattage sticker affixed to the light socket(s)
may result in fire hazard or improper operation.
Note: Globe style and number of
lights may vary.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Maintenance & Cleaning
Metal
Plate
ON
Globe
Globe
Keeper
Finial
Cap
Reverse
Switch
Finial
Changing the direction of air
flow - move the reverse switch
to the opposite position.
Cleaning the fan - use soft
brushes or cloths to prevent
scratching. Cleaning products
may damage the finishes.
Changing the bulbs - unscrew
the finial and remove it from the
threaded rod. Remove the finial cap
and unscrew the globe keeper while
supporting the globe with your other
hand. Carefully remove the globe.
Unscrew bulbs and replace with
bulbs of same type and wattage.
Reinstall the globe assembly.
For questions regarding removing a light kit, call
customer service 1-888-830-1326.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
1.888.830.1326
Troubleshooting
Fan doesn’t work
Noisy Operation
Lights dim when turned on or
do not turn on at all.
Excessive wobbling
• Make sure power switch is on.
• Tighten the blade and blade
iron screws until they are snug.
• Tighten all of the blade and
blade iron screws until they
are snug.
• Make sure the wattage of the
light bulbs installed matches
the specifications on the light
sockets.
• Pull the pull chain to make sure
it is on.
• Check to see if any of the
blades are cracked. If so, replace
all of the blades.
• Turn the power off, support
the fan carefully, and check
that the hanger ball is
properly seated.
•
Push the motor reversing switch
firmly left or right to ensure that
it is engaged.
• Check the circuit breaker to
ensure the power is turned on.
• Use the provided balancing
kit and instructions to balance
the fan.
• Make sure the blades spin freely.
• Turn off power from the circuit
breaker, then loosen the canopy
and check all the connections
according to the wiring diagram
on page 10.
• Check the plug connection in
the switch housing.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
M0050-01 • 01/30/14 • © Hunter Fan Company
|