| H808C   Convertible Dehumidifier Controller   4. Remove the humidity controller assembly by prying   Application   with a screwdriver in the notch on the bottom of the case   (Fig. 1).   The H808C Dehumidifier Controller provides automatic   5. Position the case horizontally over the wires with the   low voltage control of dehumidifiers in central heating   arrows on the tabs pointing up and secure the case to the   systems. The humidity controller has an spst, snap-acting,   wall using the two screws provided.   dust-proof switch and is designed for wall or surface duct   6. Connect the wires to the humidity controller assem-   mounting.   bly using leadwires and wire nuts provided (see Wiring   section and Fig. 2).   7. Tuck the wires into the bottom of the case.   8. Snap the cover assembly into the case (Fig. 2).   MODELS:   I H808C1029: Premier White™.   I H808C1037: Beige.   ELECTRICAL RATING: 50 VA at 24 Vac.   Fig. 1—Removing humidity controller assembly   from case.   MAXIMUM AMBIENT TEMPERATURE: 125° F [52° C].   SWITCH DIFFERENTIAL: 5 percent RH, nonadjustable.   SET POINT ADJUSTMENT RANGE: 20 to 80 percent   RH; positive ON and OFF positions.   Installation   CAUTION   1. Installer must be a trained, experienced service   technician.   2. Disconnect power supply before beginning   M9262   installation.   3. Conduct a thorough checkout before leaving   installation.   Fig. 2—Wiring connections on humidity   controller.   WALL MOUNTING   1. Locate the humidity controller about 5 ft [1.5m]   above the floor on an inside wall.   QUICK-CONNECT   WIRE LEAD   NOTES:   a. Be sure the humidity controller is subject to average   room temperature and average relative humidity.   The maximum temperature at the location selected   must not exceed 125° F [52° C].   b. The humidity controller can be mounted directly on   COVER   WIRE   NUT   the wall.   HUMIDIFIER   LEADWIRE   CASE   2. Drill a small hole in the wall.   UP   UP   3. Run low voltage wiring to the location and pull about   UP   6 in. [152 mm] of wire through the hole.   MOUNTING   HOLE (2)   NOTE: Plug the opening to prevent drafts from affecting   M9263   humidity controller operation.   J.F. • 3-94 • ©Honeywell Inc. 1994 • Form Number 69-0821   Download from Www.Somanuals.com. All Manuals Search And Download.   Fig. 5—Typical parallel wiring diagram of H808C with T87F/Q539A combination for dehumidification   and mildew control.   H808C   T87F/Q539A INTERNALSCHEMATIC   T87F   FIXED   R1   COOL   ANTICIPATOR   FILTER   LIGHT   TEMPERATURE   FALL   ADJUSTABLE   HEAT   ANTICIPATOR   W1   Y1   HEAT OFF COOL   AUTO FAN ON   HEAT   OFF   COOL   3 2 R H X B O W Y G R HEATING   RELAY OR   VALVE COIL   COOLING   CONTACTOR   COIL   FAN RELAY   COIL   1 PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS   AS REQUIRED.   HEATING DAMPER MOTOR, IF USED.   2 3 CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION.   1 M18627   Fig. 6—Typical series wiring diagram of H808C with T87F/Q539A combination for dehumidification and   mildew control.   H808C   T87F/Q539A INTERNALSCHEMATIC   T87F   FIXED   R1   COOL   ANTICIPATOR   FILTER   LIGHT   TEMPERATURE   FALL   ADJUSTABLE   HEAT   ANTICIPATOR   W1   Y1   HEAT OFF COOL   AUTO FAN ON   HEAT   OFF   COOL   3 2 R H X B O W Y G R HEATING   RELAY OR   VALVE COIL   COOLING   CONTACTOR   COIL   FAN RELAY   COIL   1 PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS   AS REQUIRED.   HEATING DAMPER MOTOR, IF USED.   2 3 CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION.   1 M18626   3 69-0821   Download from Www.Somanuals.com. All Manuals Search And Download.   DUCT MOUNT HUMIDITY CONTROLLER   If the temperature at the humidity controller location   on the return air duct is less than 80° F [27° C] ,use the   procedure for wall mounted humidity controllers.   If the air surrounding the humidity controller is greater   than 80° F [27° C], reset the recommended settings to   compensate for the higher ambient temperature. High ambi-   ent temperatures will cause the humidity controller to control   at an increased setting. To determine the compensated set   point for surface mounted humidity controllers with high   ambient temperatures, use the following procedure:   1. With a bulb type thermometer, accurately determine   the surrounding duct temperature at the humidity controller   location.   Fig. 7—Typical wiring diagram for H46C,E.   HUMIDITY   1 RISE   DEHUMIDIFIER   L1   EXHAUST FAN   (HOT)   OR AIR   CONDITIONER   H46C, E CONTROLLER   L2   1 POWER SUPPLY. PROVIDE DISCONNECT MEANS   AND OVERLOAD PROTECTION AS REQUIRED.   M9297   WIRING   All wiring must comply with local codes and ordi-   nances. Make wiring connections according to to dehu-   midifier instructions if available; otherwise, see typical   wiring diagrams in Figs. 5 and 6.   2. Decrease the recommended setting about five percent   for each 5° F [3° C] above 80° F [27° C] at the humidity   controller.   For example, if the humidity controller is set at 25 per-   cent and the temperature at the humidity controller is 90° F   [32° C], the compensated set point should be 15 percent.   (This is the 25 percent setting less 10 percent for the 10° F   [6° C] above ambient temperature.)   Settings   HUMIDITY CONTROLLER ADJUSTMENT   The humidity comfort range of a living space is gener-   ally between 25 and 50 percent RH. However, as the   outdoor temperature changes, the humidity level on the   humidity controller may need to be reset to assure maxi-   mum comfort.   To reduce the relative humidity, reduce the set point ap-   proximately three percent RH every 24 hours. To increase   the relative humidity, increase the set point approximately   three percent RH every 24 hours.   Checkout   Place the system in operation and observe through at   least one complete cycle to make certain that all compo-   nents are functioning properly.   WALL MOUNT HUMIDITY CONTROLLER   Set the humidity set point according to the prevailing   outdoor temperature to provide optimum relative humidity   control for most installations. Adjust the humidity level to   a particular structure using the procedure above.   Home and Building Control   Honeywell Inc.   1985 Douglas Drive North   Golden Valley, MN 55422   Home and Building Control   Honeywell Limited—Honeywell Limitée   740 Ellesmere Road   Scarborough, Ontario   M1P 2V9   Helping You Control Your World   QUALITY IS KEY   PrintedinU.S.A.   Download from Www.Somanuals.com. All Manuals Search And Download.   |