Harman Stove Company Indoor Fireplace 1 90 79700 User Manual

Owner's Manual  
Installation and Operation  
Model:  
Oakleaf  
Non-Catalytic, Top Load,  
Wood Burning Room Heater  
Item #1-90-797000  
NOTICE  
dO NOT dIsCaRd THIs MaNuaL  
Read, understand and Leave this manual with  
follow these instructions party responsible for use  
for safe installation and and operation.  
operation.  
Important operating and  
maintenance instructions  
included.  
WaRNINg  
WaRNINg  
pLEasE REad THIs ENTIRE MaNuaL  
BEfORE INsTaLLaTION aNd usE Of  
THIs WOOd-BuRNINg ROOM HEaTER.  
fa I L u R E TO f O L L O W T H E s E  
INsTRuCTIONs COuLd REsuLT IN  
pROpERTy daMagE, BOdILy INjuRy  
OR EvEN dEaTH.  
HOT suRfaCEs!  
gLass aNd OTHER suRfaCEs aRE HOT  
duRINg OpERaTION aNd COOL dOWN.  
HOT, WILL CausE BuRNs.  
dO NOT TOuCH gLass uNTIL IT Is COOLEd  
NEvER aLLOW CHILdREN TO TOuCH gLass  
kEEp CHILdREN aWay  
CaREfuLLy supERvIsE CHILdREN IN saME  
ROOM as fIREpLaCE.  
aLERT CHILdRENaNd aduLTs TO HazaRds Of  
HIgH TEMpERaTuREs.  
HIgH TEMpERaTuREs May IgNITE CLOTHINg  
OR OTHER fLaMMaBLE MaTERIaLs.  
kEEp CLOTHINg, fuRNITuRE, dRapERIEs aNd  
OTHER fLaMMaBLE MaTERIaLs aWay.  
dO NOT sTORE OR usE gasOLINE OR OTHER  
fLaMMaBLE vapORs aNd LIquIds IN THE  
vICINITy Of THIs OR aNy OTHER appLIaNCE.  
dO NOT OvERfIRE - If aNy ExTERNaL paRT  
sTaRTs TO gLOW, yOu aRE OvERfIRINg. CLOsE  
aIR CONTROLs. OvERfIRINg WILL vOId yOuR  
WaRRaNTy.  
• COMpLy WITH aLL MINIMuM CLEaRaNCEs TO  
COMBusTIBLEs as spECIfIEd. faILuRE TO  
COMpLy May CausE a HOusE fIRE.  
CauTION  
CHECk BuILdINg COdEs pRIOR TO INsTaLLaTION.  
CauTION  
TEsTEd aNd appROvEd fOR usE WITH dRy,  
sEasONEd CORdWOOd ONLy. dO NOT BuRN WET  
OR gREEN WOOd. BuRNINg aNy OTHER TypE Of  
fuEL WILL vOId yOuR WaRRaNTy.  
INsTaLLaTION MusT COMpLy WITH LOCaL, REgIONaL, sTaTE  
aNd NaTIONaL COdEs aNd REguLaTIONs.  
CONsuLT LOCaLBuILdINg, fIRE OffICIaLs ORauTHORITIEs  
HavINg juRIsdICTIONaBOuT REsTRICTIONs, INsTaLLaTION  
INspECTION, aNd pERMITs.  
3-90-798  
Rev: 5  
May, 2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
TaBLE Of CONTENTs  
section 1: Listing and Code approvals  
section 9: service & Maintenance  
A. Soot Formation (Removal)  
A. Appliance Certifications  
B. Mobile Home Approval  
C. Glass Specifications  
4
28  
29  
4
4
4
4
B. General Maintenance Procedures  
D. Electrical Rating  
section 10: Reference Materials  
A. Wiring Diagram (Blower Option)  
B. Service Parts Listing  
E. BTU & Efficiency Specifications  
31  
32  
35  
36  
section 2: special Warnings and Notes  
C. EPA Hang Tag  
D. Warranty Policy  
A. Carbon Monoxide Warnings &  
Considerations  
5
section 3: getting started  
A. Design, Installation & Location6  
B. Fire Safety  
6
7
7
8
C. Component Locator  
D. Flue Direction Conversion  
E. Pre-Use Checklist  
section 4: dimensions & Clearances  
A. Appliance Dimensions  
B. Clearances to Combustibles  
C. Floor Protection  
section 5: Chimneys and venting  
A. Draft  
9
10  
12  
This room heater must be connected to  
1) a chimney complying with the requirements for  
Type HT chimneys in the standard for Chimneys,  
factory-Built, Residential Type and Building  
Heating appliance, uL 103  
13  
13  
13  
14  
B. Chimney Connectors  
C. Wall Pass-Throughs  
D. The Chimney  
or  
2) a Code approved Masonry Chimney with a flue  
Liner.  
section 6: Mobile Home - (us only)  
A. Mobile Home Installation  
21  
section 7: appliance set-up  
A. Outside Air Attachment  
B. Leveling The Appliance  
C. Optional Cooking Grill  
22  
22  
22  
23  
23  
23  
D. Optional Blower Kit  
E. Optional Rear Vent Rear Shield  
F. Optional Bottom Heat Shield  
section 8: Operating Instructions  
A. Fuel Specifications  
24  
24  
25  
26  
26  
26  
B. General Operating Information  
C. Combustion Process  
D. User Controls  
E. Before Your First Fire  
F. Building & Maintaining a Fire  
3
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
Listing and Code approvals  
1
E. BTu & Efficiency specifications  
a. appliance Certification  
Model:  
Oakleaf Woodburning Stove  
OMNI-Test Laboratories, Inc.  
135-S-26-6.2  
Solid Fuel Room Heater / Wood  
Burning Type.  
Particulate Emissions  
Rating:  
2.2g/hr Avg  
Laboratory:  
Report No.  
Type:  
15,000 - 39,000 / hr  
*BTU Input:  
Heating Capacity:  
Firebox Size:  
Fuel:  
1,400-1,600 sq. ft.††  
1.7 cu. ft.  
Dry Cordwood  
430 lbs.  
Standard(s):  
UL1482-10, &  
ULC S627-00  
Shipping Weight:  
This appliance is also approved for installation in  
a shop.  
*BTU input based on EPA test fuel. Actual cordwood  
values will vary.  
B. Mobile Home approved  
††Heating capacity based on zones 1 and 2, covering  
the Northern United States.  
This appliance is approved for Installation in mobile/  
manufactured homes in the us only. The structural  
integrity of the mobile home floor, ceiling and walls  
must be maintained. The appliance must be properly  
grounded to the frame of the mobile home, and must  
never be installed in a room designated for sleeping.  
The unit must have provisions for an outside air source  
when installed in a mobile home.  
C. glass specifications  
This appliance is equipped with 5mm ceramic glass.  
Replace glass only with 5mm ceramic glass. Please  
contact your dealer for replacement glass if needed.  
d. Electrical Rating  
Optional Blower: 115 VAC, 60 Hz. <1 Amps  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
special Warnings and Notes  
2
Carbon monoxide, referred to as CO, is a colorless,  
CO detectors are very sensitive and may sound an alarm  
for fumes other than CO or CO from sources other than  
the stove such as car or lawn mower exhaust.  
If the alarm sounds  
odorless gas that is produced during combustion of wood  
and other fuels. CO fumes are toxic and can be fatal.  
The Oakleaf is a natural draft system which relies on  
a properly designed chimney to remove CO and other  
combustion by-products from the stove.  
1. Increase ventilation by opening windows or doors.  
2. Make sure the stove doors and lid are closed and latched.  
3. Check stove for smoking or puffing condition. Open  
by-pass and increase air-flow to firebox, if needed.  
4. Check chimney for possible blockage or down-draft.  
5. Check for false alarm.  
Even though this stove is designed to be as safe as  
possible, it is important that you install a CO detector.  
This is true for oil, gas, or coal burning products as well.  
CO is not specifically heavier or lighter than air.  
Therefore, it is best to install the detector at table top level  
rather than on the ceiling like a smoke detector.  
Never use gasoline, lantern fuel, kerosene,  
charcoal lighter fluid, or similar liquids to start  
or “freshen up” a fire in this heater. keep all  
such liquids well away from the heater while it  
is in use.  
NEvER CONNECT THIs uNIT TO a CHIMNEy  
fLuE sERvINg aNOTHER appLIaNCE.  
Installation and repair of this stove should  
be done by a qualified service person. We  
recommend that the stove be inspected  
before use and at least annually by a qualified  
service person. periodic cleaning is required  
throughout the heating season and at the end  
of each winter for the stove to work efficiently.  
spECIaL NOTE:  
duE TO asH BuILdup, IT Is sTRONgLy  
RECOMMENdEd TO HavE yOuR sTOvE  
pROfEssIONaLLyCLEaNEdaNdsERvICEd  
aNNuaLLy. THIs INCLudEs aLL paRTs Of  
THE sTOvE, aNd THE vENTINg sysTEM.  
dO NOT CONNECT TOaNyaIR dIsTRIBuTION  
duCT OR sysTEM.  
If INsTaLLINg ON a COMBusTIBLE fLOOR,  
THE BOTTOM HEaT sHIELd MusT BE  
INsTaLLEd aLONg WITH pROpER fLOOR  
pROTECTION MaTERIaL.  
5
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
getting started  
3
a. design, Installation & Location  
Considerations  
B. fire safety  
Maintain the designated clearances to combustibles.  
Insulation must not touch the chimney. You must  
maintain the designated air space around the chimney.  
This space around a chimney is necessary to allow  
natural heat removal from the area. Insulation in this  
space will cause a heat buildup, which may ignite wood  
framing. NOTE: Clearances may only be reduced  
by means approved by the regulatory authority  
having jurisdiction.  
1. appliance Location  
Consideration must be given to safety, convenience,  
traffic flow, and the fact that the appliance will need  
a chimney and chimney connector. It is a good  
idea to plan your installation on paper, using exact  
measurements for clearances and floor protection,  
before actually beginning the installation. When  
installing on a combustible floor, the optional bottom  
heat shield must be installed along with using proper  
floor protection material. See page 12 for details.  
To provide reasonable fire safety, the following should  
be given serious consideration:  
1. Install at least one smoke detector on each floor  
of your home. Detectors should be located away  
from the heating appliance and close to sleeping  
areas. Follow the smoke detector manufacturer's  
placement and installation instructions, and be  
sure to maintain regularly.  
Maintain specified vent clearance to combustible  
requirements listed by the vent manufacturers  
instructions and all clearance to combustibles listed in  
this manual.  
2. A conveniently located Class A fire extinguisher  
to contend with small fires resulting from burning  
embers.  
3. A practiced evacuation plan, consisting of at least  
two escape routes.  
Check with your local building code agency before  
you begin your installation. Be sure local codes do not  
supersede UL specifications and always obtain the  
required permit so that insurance protection benefits  
cannot be unexpectedly cancelled. If any assistance is  
required during installation, please contact your dealer.  
4. A plan to deal with a chimney fire as follows:  
In the event of a chimney fire:  
a. Evacuate the house immediately.  
b. Notify Fire Department.  
c. Never apply water to a suspected chimney fire.  
Serious damage could occur.  
We recommend that a qualified building inspector and  
your insurance company representative review your  
plans before and after the installation.  
Be sure to provide a source of fresh air to the room  
or directly to the appliance. Make-up air is needed to  
replace what the chimney draws away through the  
appliance.  
WaRNINg  
fIRE HazaRd  
dO NOT OpERaTE appLIaNCE  
BEfORE REadINg aNd  
CauTION  
uNdERsTaNdINg THE OpERaTINg  
INsTRuCTIONs.  
faILuRE TO OpERaTE pROpERLy  
May CausE a HOusE fIRE.  
dO NOT CONNECT THIs uNIT TO a CHIMNEy fLuE  
sERvICINg aNOTHER appLIaNCE.  
dO NOT CONNECT TO aNy fORCEd aIR  
dIsTRIBuTION duCT OR sysTEM.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
C. Component Locations  
Top Load Door  
Top Load Opening  
Bypass Damper  
Control Handle  
Front Load Door  
Air Control  
Front Load  
Door Latch  
Ash Door  
Level  
adjuster  
Ash Door  
Latch  
d. flue direction Conversion  
The Oakleaf features an adjustable flue collar for rear or top exit. Follow these instructions for changing the  
direction. First, remove the upper rear heat shield by removing 8 tek screws that secure it. Reaching upward  
through the firebox and the open bypass damper, loosen the retainer bolts on each of the flue collar and the cast  
iron plate. With the bolts loosened, turn the retainer to allow the piece to come free of the stove body. Reposition  
the flue collar and the cast iron plate and secure them with the retainers by tightening the bolts. You will now need  
to install a different upper rear heat shield. (See page 23).  
7
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
E. pre- use Check List  
1.  
Place the appliance in a location near the  
final installation and follow the procedures  
below:  
WaRNINg  
INspECT appLIaNCE aNd  
COMpONENTs fOR daMagE. daMagEd  
paRTs May IMpaIR safE OpERaTION.  
2.  
Open the appliance and remove all articles  
packed inside. Inspect all items for shipping  
damage. Notify dealer of any missing or  
damaged goods.  
All safety warnings have been read and  
followed precisely.  
This Owner's Manual has been read in it's  
entirety.  
Floor protection requirements have been  
read and followed.  
The flue connector has been installed in  
accordance with the instructions herein.  
The proper clearances from the appliance  
and chimney connector to combustibles  
have been met.  
The masonry chimney has been cleaned  
and inspected by a professional, or the  
factory built metal chimney is installed  
according to the manufacturers instructions.  
The chimney meets the minimum height  
requirements.  
All labels and hang tags have been removed  
from the glass.  
All plated surfaces have been wiped clean,  
if applicable.  
The optional air distribution blower  
has been installed properly.  
A properly grounded electrical receptacle is  
available within reach of the blower's power  
cord (if installed).  
dO NOT INsTaLL daMagEd  
COMpONENTs.  
dO NOT INsTaLL INCOMpLETE  
COMpONENTs.  
dO NOT INsTaLL suBsTITuTE  
COMpONENTs.  
3.  
4.  
5.  
6.  
7.  
REpORT daMagEd paRTs TO dEaLER.  
WaRNINg  
fIRE RIsk.  
HEaRTH & HOME TECHNOLOgIEs  
dIsCLaIMs aNy REspONsIBILITy  
fOR, aNd THE WaRRaNTy WILL  
BE vOIdEd By, THE fOLLOWINg  
aCTIONs:  
8.  
INsTaLLaTION aNd usE Of aNy daMagEd  
appLIaNCE.  
9.  
MOdIfICaTION Of THE appLIaNCE.  
INsTaLLaTION OTHER THaN as INsTRuCTEd By  
HEaRTH & HOME TECHNOLOgIEs.  
INsTaLLaTION Of paRTs OR COMpONENTs NOT  
suppLIEd OR appROvEd By HEaRTH & HOME  
TECHNOLOgIEs.  
OpERaTINg appLIaNCE WITHOuT THE LEgs  
aTTaCHEd.  
OpERaTINg appLIaNCE WITHOuT fuLLy  
assEMBLINg aLL COMpONENTs.  
dO NOT OvERfIRE.  
10.  
11.  
12.  
13.  
OR aNy suCH aCTION THaT May CausE a fIRE  
HazaRd.  
There are two brick clips located in the Owner’s manual bag. With the bricks in place, install the clips in the front corners  
as shown. The long portion of the clip will fit between the brick and the wall of the stove, with the short hook over-hanging  
to the inside of the firebox.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
dimensions & Clearances  
4
a. appliance dimensions  
25"(635mm)  
air Intake  
29.2"  
(742mm)  
10.2"  
(259mm)  
27.2"  
(691mm)  
When configured for rear flue; floor to center of flue  
measures 23.5" (597mm)  
NOTICE: When using rear flue configuration, a new  
upper rear heat shield, #1-00-797066 must be installed  
in place of the existing shield.  
26.2"  
(665.5mm)  
Centered  
Weight  
430 lbs  
Flue Size  
6 inch  
Log Length Recommended  
Average Emissions  
Outside Air size  
18"  
27.6"  
(701mm)  
2.2 Grams Per Hr.  
4.5 inch I.D.  
25.6"  
(650mm)  
18.9"  
(480mm)  
The Harman Oakleaf meets the  
U.S. Environmental Protection  
Agency’s emission limits for wood  
heaters sold after July 1, 1990.  
9
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
B. Clearances To Combustibles  
CLEaRaNCE TO COMBusTIBLEs: vertical venting Configuration  
Location  
pipe clearance may be reduced using double wall  
or insulated connector pipe, provided that you  
adhere to the specified clearances from the stove  
itself. follow pipe manufacturer's guidelines.  
a
B
C
d*  
unit to side Wall  
unit to Back Wall  
vent pipe to side Wall  
vent pipe to Back Wall  
17" / 432 mm  
14" / 356 mm  
26.75" / 679 mm  
*17.5" / 444 mm  
d*  
B
C
* Nfpa 211 specifies 18" clearance to  
single wall connector pipe. This lower  
clearance is based on actual safety  
test conditions.  
a
for clearance reduction methods, refer to Nfpa 211 or Local Codes  
CLEaRaNCE TO COMBusTIBLEs: vertical vent, Horizontal Exit  
Location  
pipe clearance may be reduced using double wall  
a
B
C
d*  
E*  
f
unit to side Wall  
unit to Back Wall  
vent pipe to side Wall  
vent pipe to Back Wall  
vent pipe to Ceiling  
Minimum vertical  
16" / 407 mm  
13" / 330 mm  
25.25" / 641 mm  
*17" / 432 mm  
*16" / 407 mm  
0" / 0 mm  
or insulated connector pipe, provided that you  
adhere to the specified clearances from the stove  
itself. follow pipe manufacturer's guidelines.  
* Nfpa 211 specifies 18" clearance to  
single wall connector pipe. This lower  
clearance is based on actual safety  
test conditions.  
E
E
f
C
d
C
a
B
a
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
pipe clearance may be reduced using double wall or insulat-  
ed connector pipe, provided that you adhere to the specified  
clearances from the stove itself. follow pipe manufacturer's  
guidelines.  
CLEaRaNCE TO COMBusTIBLEs: Corner Installation,  
vertical vent  
Location  
a
B
shield Corner to Wall  
vent pipe to Wall  
14" / 356 mm  
21.75" / 552 mm  
B
a
B
a
B
a
CLEaRaNCE TO COMBusTIBLEs: Corner Installation  
vertical vent, Horizontal Exit  
Location  
a
B
shield Corner to Wall  
vent pipe to Wall  
14" / 356 mm  
21.75" / 552 mm  
*for clearance reduction methods, refer to Nfpa 211 or Local Codes  
CLEaRaNCE TO COMBusTIBLEs: Horizontal venting Configuration  
Location  
a
B
C
unit to side Wall  
unit to Back Wall  
vent pipe to side Wall  
17" / 432 mm  
13" / 330 mm  
26.5" / 673 mm  
Corner Installation  
d
E
shield Corner to Wall  
Nfpa 211 specifies clearance of  
14" / 356 mm  
18" / 457 mm  
(although vent clearance may be reduced using double-wall pipe, d must be  
followed)  
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in  
place of the existing shield.  
C
B
a
E
d
11  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
C. floor protection Requirements  
daNgER: The appliance legs may not be removed  
for installation.  
Minimum Size floor protection (USA) is 48" Deep By  
32.5" Wide.  
L
floor protection  
Requirements  
Inches  
Millimeters  
8
203  
457  
203  
Wall  
Sides- USA /CANADA *  
Front- USA /CANADA *  
Rear- USA  
j
k
L
L
18  
8
j
j
Rear- CANADA  
Wall  
k
* Floor protection for the front and sides as measured  
from the appliance door opening.  
floor protection Requirements  
If the Oakleaf is being installed on a combustible  
floor, the bottom heat shield (part # 1-00-797058) must  
be installed along with proper floor protection material.  
(See page 25). Floor protection must be a minimum  
3/8" (9.5mm) thickness of material having an insulating  
value equal to or better than 0.84k/in. (The lower the k  
value, the better the protection.)  
Minimum 60" corner floor protection (USA & CANADA).  
Another method for calculating floor protection is in  
R value. This requirement would be for an R value of  
0.45 or higher. (The higher the R value, the better the  
protection). Example- 1 inch of Durock® = 0.52R  
In all installations, the area under and around the  
stove must be protected from falling ash and live coals.  
The area under a horizontal run of chimney connector  
must also be protected, extending two (2) inches  
beyond the measurement of the horizontal connector.  
Further guidelines for floor protection are as follows:  
In the U.S. the floor protector must be completely  
under the stove, and extending 16" in front of the door  
opening, 8" to each side and 8" to the back.  
In Canada, the floor protection must extend 18"  
(457mm) in front of the door opening, 8" (203mm) to  
each side and extend to the wall behind the stove.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
The Chimney Connector shall Not pass Through an  
attic or Roof space, Closet or similar Concealed space,  
a floor or Ceiling.  
Chimneys and venting  
5
Assemble the connector beginning at the flue collar,  
with the crimped ends pointing towards the stove (to  
keep debris or residue inside the system). Each joint,  
including the one to the stove’s flue collar and the one  
to the chimney itself should be secured with at least  
three sheet metal screws. Screws may be a maximum  
of 3 inches apart. A 1-1/4" (30 mm) overlap is required  
at each joint, including the flue collar attachment. No  
more than two 90 degree elbows should be used, and  
the total length of connector should not exceed 10 feet  
(3 m). All horizontal runs of connector must have a  
minimum upward slope of 1/4"(6 mm) per foot (20 mm  
per meter).  
a. draft  
Draft is widely misunderstood. It is important that  
you, the stove operator, realize that draft is a variable  
effect, not a given quantity. Stoves and chimneys  
do not have draft, yet draft is the key to your stove’s  
performance.  
Draft is a force, produced by an operating stove  
and the chimney to which it is attached. It is created by  
hot gases rising up the chimney, creating a pressure  
difference between the inside of your home and the  
outside air. It continually moves fresh combustion air  
into the stove, and hot exhaust gases out of the stove;  
without this constant flow, the fire will go out.  
Other factors, such as barometric pressure,  
winds, the airtightness of the home, the total inside  
chimney volume, chimney height and the presence  
of venting devices such as exhaust fans also play a  
role in maintaining an adequate draft. Low barometric  
pressures, super insulated homes and exhaust fans can  
reduce draft; winds can play havoc with draft; and too  
large or too small a chimney volume can cause reduced  
draft due to the excessive cooling or not enough room  
to vent exhaust gases. Introducing outside air directly  
to the stove may help remedy a low draft problem.  
Some signs of inadequate draft are smoking, odor,  
difficulty in maintaining the fire, and low heat output.  
Overdraft can be caused by a very tall chimney even if  
it is the recommended size, and can cause overfiring  
of your stove. Signs of an overdraft include rapid fuel  
consumption, inability to slow the fire, and parts of the  
stove or chimney connector glowing red. It is important  
that you follow the chimney guidelines in this manual,  
including size, type, and height to avoid draft problems.  
When installed and operated according to this  
manual, the Oakleaf will produce enough hot gases  
to keep the chimney warm so that adequate draft is  
maintained throughout the burn cycle.  
The chimney connector diameter should correspond  
to the size of the flue collar opening. Do not use  
makeshift compromises. No part of the chimney  
connector may pass through an attic or roof cemented  
in place with refractory cement.  
C. Wall pass-thrus  
Depending on your local building codes, and the  
pertinent provincial or national codes, there are several  
choices for passing the chimney connector safely  
through a wall. Before beginning your installation,  
contact local officials, and also the chimney connector  
and chimney manufacturer for specific requirements.  
Canada. Three methods are approved by the  
Canadian Standards Association. The diagram on the  
next page shows one method requiring an 18"(450 mm)  
air space between the connector and the wall. It allows  
use of one or two covers as described in the diagram.  
The two other methods are described in detail in the  
current issue of CAN/CSA B365, the national standard.  
United States In the U.S., the national code is NFPA  
211. While many localities adopt this standard, be sure  
to check with local authorities before beginning your  
installation.  
The NFPA(National Fire ProtectionAgency) permits  
four methods for passing through a combustible wall. A  
commonly used method to pass through a wall directly  
to a masonry chimney is to clear a minimum 12"(300  
mm) around the entire chimney connector, and fill it  
with brick masonry which is at least 3.5"(90 mm) thick.  
A fireclay liner, minimum 3/8" (9 mm) wall thickness  
must run through the brick wall to the chimney liner (but  
not beyond the inner surface of the liner). It must be  
cemented in place with refractory cement. This method  
is illustrated on the next page. For details on the other  
three options, refer to the most recent edition of the  
NFPA 211 code.  
B. Chimney Connectors  
In general, following these guidelines will ensure  
compliance with all national and provincial codes;  
prior to beginning your installation, check with your  
local building code official to check on additional  
local regulations which may influence the design and  
placement of your venting system.  
TheHarmanOakleaf maybeinstalledwithaminimum  
(.6 mm) 24 gauge chimney connector pipe. The size of  
the connector should correspond to the size of the flue  
collar opening. Do not use makeshift compromises. No  
part of the chimney connector may pass through an  
attic or roof space, closet or other concealed space,  
or through a floor or ceiling. Whenever possible, avoid  
passing the connector through a combustible wall; if you  
must, use an approved wall pass-through, described  
later in this section.  
13  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
Non-combustible cover,  
one side only. If two  
covers are used, each  
must be mounted on  
non-combustible spacers  
at least 7/8" (21mm) away  
from the wall.  
Closest  
Combustible  
Material  
Minimum 2" (50mm)  
Clearance to Brick  
Hole with a minimum clear-  
ance of 18" (450 mm) be-  
tween connector and wall.  
Minimum 12"  
Liner  
(300mm) to Brick  
Fire Clay  
Thimble  
Chimney  
Connector  
1" (25mm)  
Clearance  
Masonry Chimney Built to  
NFPA 211 Specifications.  
Minimum 12" (300mm)  
to Combustibles  
AN APPROVED CANADIAN  
WALL PASS-THROUGH  
AN APPROVED U.S.  
WALL PASS-THROUGH  
d. The Chimney  
This unit must be installed into a chimney approved  
for use with solid-fuel appliances. In the U.S., it must  
be connected to (1) a prefabricated chimney complying  
with the requirements for Type HT chimneys in the  
Standard for Chimneys, Factory-Built, Residential Type  
and Building HeatingAppliances, UL103, or (2) a code-  
approved masonry chimney with a flue liner.  
In Canada, this unit is listed for use with prefabricated  
chimneys tested and listed to the high temperature (650  
degrees C) chimney standard, ULC S-629, or with a  
code approved masonry chimney.  
Do not connect this unit to a chimney  
flue servicing another appliance.  
NOTE: The restriction of not venting more than one appliance  
to the same flue applies to the U.S. specifically. While it is not  
recommended that you use the same chimney for more than  
one appliance, in Canada certain exceptions may be made.  
Be sure to contact your building code inspection official to  
see if this option is allowed in your area, and to find out the  
specific requirements for such an installation.  
For mobile homes, (US only) it must only be installed  
with a factory built stainless steel chimney. The  
chimney system should include all required installation  
components, such as vapor barriers and roof flashing,  
as tested for use in mobile homes.  
The minimum recommended height for any chimney  
is 16 ft. (4.8 m) above flue collar height. For non-mobile  
home installations, a round flue (either masonry or  
approved prefabricated), of either 6" (150 mm), 7"  
(180 mm) or 8" (200 mm) may be used. For square or  
rectangular masonry chimneys, nominal sizes of 8" x  
8" or 7" x 12" (200mm x 200 mm, 180 mm x 300 mm)  
may be used.  
More Than 10 ft. (3m)  
Height Necessary  
Above Any Roof  
Surface Within 10ft.  
10 ft. (3m)  
(3m)  
2 ft. (0.6m) min.  
3ft. (0.9m)  
minimum  
above  
exit  
point  
Ridge  
Codes require that solid-fuel chimneys extend 3 ft.  
(0.9 m) above the highest point at which they exit from  
the roof. Then, the chimney must extend 2 ft. (0.6 m)  
above the highest point within a 10 ft (3 m) radius. Thus,  
the 3 foot, 2 foot, 10 foot rule:  
Chimney  
The 3-foot, 2-foot, 10 foot rule  
3ft. - Above roof exit point  
2ft. - Higher than anything within-  
10ft. of the chimney.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
1. Existing Masonry Chimneys  
If you plan on using a pre-existing masonry chimney,  
have it thoroughly inspected and cleaned. Any faults  
which make the chimney unsafe and unusable must  
be repaired prior to use. These can include improper  
height, structural defects, blockages, inadequate  
clearance to combustibles, unsealed openings into  
other rooms of the house, signs of creosote or smoke  
leakage, a loose or absent clean-out door, or absence  
of a liner.  
2. venting to a Masonry Chimney  
When connecting to a masonry chimney, several  
provisions are standard. First, whether the chimney  
connector is vented to the chimney through a thimble  
or a breech pipe, neither must pass beyond the inner  
surface of the chimney liner, and both must be firmly  
cemented in place with refractory cement. (Athimble is  
a masonry pipe which is inserted through the chimney  
wall, and is frequently the preferred method; a breech  
pipe is a piece of steel pipe used the same way.) In  
Canada, a breech pipe has ridges or protrusions to  
lock it firmly into the refractory cement. In either case,  
the chimney connector vents to the chimney through  
the thimble or breech pipe.  
Using a thimble, the connector slides completely  
inside the masonry to the inner edge of the flue liner,  
and may be easily removed for chimney and connector  
inspection. A breech pipe must extend at least 2" (50  
mm) into the room, so the connector can be attached  
with sheetmetal screws.  
4. Installing to a prefabricated Chimney  
When venting using a prefabricated chimney, be sure  
to contact local building code authorities, and to follow  
the manufacturer’s instructions exactly. Use only the  
manufacturer’s parts; do not use makeshift installation  
techniques. All prefabricated chimneys must be  
tested to either the U.S. or Canadian high-temperature  
standards, UL 103 or ULC S629.  
3. venting to a Masonry fireplace Chimney  
5. Other Considerations  
Insomesituations, acodecompliantchimneyoriginally  
used for a masonry fireplace may be used. In addition  
to the requirements found in the previous paragraphs,  
it is important to be aware that all clearances must be  
met, including those from the chimney connector to  
combustibles. Do not forget to include floor protection  
in your plans. (See Clearances and Floor Protection  
in this section.) Since many fireplaces have exposed  
wooden mantels and trim, pay special attention to the  
clearances necessary to these materials.  
If your fireplace chimney is behind a combustible wall,  
you must use an approved wall pass-through system  
to gain access to the masonry chimney. The chimney  
connector must enter the chimney at a place where it is  
lined, and the fireplace must be made inoperable. For  
example, you might remove the damper, replacing it  
with a secure, airtight, noncombustible seal (removable  
for inspection); this also satisfies the requirement that  
no room air must be allowed to enter the chimney.  
Do not burn any fuel other than dry cordwood. Never  
use highly volatile substances in your stove, such as  
gasoline, which could cause an explosion.  
When solid fuels are burned completely, they produce  
water and carbon dioxide. However, in long slow  
burns, a substantial amount of carbon monoxide may  
be produced. If allowed to build up, carbon monoxide  
(which is odorless) can prove fatally poisonous. Proper  
ventilation and draft will prevent this from happening.  
If you smell smoke, thoroughly ventilate your dwelling,  
and contact your dealer for service.  
Other causes of poor ventilation or draft are icing,  
exhaust fans, a blocked outside air inlet, and room  
air starvation. If your stove is sluggish and you get  
occasional odor, check these possibilities and increase  
the air flow in your home.  
15  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
standard Ceiling Installation with  
factory Built Chimney  
Cathedral Ceiling Installation with  
factory Built Chimney  
Chimney Cap  
storm Collar  
Chimney  
sections  
Chimney Cap  
Roof flashing  
Roof Radiation  
shield  
Roof  
Radiation  
factory-Built  
Metal Chimney  
shield  
attic  
Radiation  
shield  
sealed storm Collar  
Roof flashing  
Cathedral style  
Chimney support  
Minimum air space  
with Chimney Listing  
Chimney  
support  
finishing  
Collar  
Chimney  
Connector  
Chimney  
Connector  
The Chimney Connector shall Not pass Through an attic or Roof space, Closet or similar Concealed space, a  
floor or Ceiling.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
Chimney Breach fireplace Conversion with Non-Combustible Wall  
Minimum Clearance  
to unprotected  
Ceiling 16"  
Chimney Connector  
sealed at Thimble  
flue Liner with  
Required air space  
airtight  
insulated  
Clean-  
out  
Three sheet Metal  
screws per joint of  
Chimney Connector  
Mantel and Trim  
protection  
damper  
Closed  
and sealed  
with Non-  
Combustible  
Material.  
floor protection*  
Combustible floor  
* floor protection in accordance  
with solid fuel appliance Listing  
The Chimney Connector shall Not pass Through an attic or Roof space, Closet or similar Concealed space, a  
floor or Ceiling.  
17  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
Oakleaf to flue fireplace Conversion (Minimum Nfpa 211 Liner Connection)  
flue Liner with Required  
air space  
airtight  
insulated  
Clean-Out  
stainless steel Chimney  
Connector Must Extend  
to flue Liner  
Minimum 8" Masonry  
Thickness in front of  
smoke Chamber  
use damper adapter  
or seal with Non-  
Combustible Material  
damper plate  
is Removed or  
fastened in Open  
position  
Listed fireplace  
Trim protection for  
Reduced Clearance  
floor protection*  
Combustible floor  
*floor protection in accordance with solid fuel appliance Listing  
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in  
place of the existing shield.  
The Chimney Connector shall Not pass Through an attic or Roof space, Closet or similar Concealed space, a  
floor or Ceiling.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
full Relining fireplace Conversion: freestanding appliance  
uL1777 stainless steel Liner system or  
Other approved lining system  
follow liner manufacturer's  
instructions on insulation and  
support  
uL1777 Insulated stainless  
steel flex Liner or Other  
approved Lining system in  
Offsets.  
Listed fireplace Trim protection for  
Reduced Clearance  
damper plate Removed or  
fastened in Open position  
use damper adapter  
or seal with Non-  
Combustible Material  
floor protection*  
Combustible floor  
*floor protection in accordance with solid fuel appliance Listing  
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in  
place of the existing shield.  
The Chimney Connector shall Not pass Through an attic or Roof space, Closet or similar Concealed space, a  
floor or Ceiling.  
19  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
Chimney Breach fireplace Conversion with Combustible Wall  
Minimum Clearance from  
Chimney Connector to  
unprotected Ceiling  
16"**  
flue Liner with Required air space  
Listed or approved Thimble assembly  
Combustible  
Wall  
1"Clearance for Complexity  
Exterior Chimney or 2"  
Clearance for Interior  
Chimney and 2" Clearance  
for Nfpa 211-Type  
sheetrock  
airtight  
insulated  
Clean-out  
approved Thimbles  
Mantel & Trim  
protection  
damper Closed  
and sealed with  
Non-Combustible  
Material.  
floor protection*  
Combustible floor  
* floor protection in accordance with solid fuel appliance Listing  
** Check with your local building codes for clearance.  
The Chimney Connector shall Not pass Through an attic or Roof space, Closet or similar Concealed space, a  
floor or Ceiling.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
Mobile Home  
6
a. Mobile Home Installation  
CauTION  
Mobile home approval - u.s. only.  
dO NOT INsTaLL IN a MOBILE HOME IN CaNada.  
MaINTaIN sTRuCTuRaL INTEgRITy Of MOBILE HOME:  
fLOOR, WaLL, CEILINg aNd/OR ROOf.  
1. An outside air inlet must be provided for combustion  
air, and must remain clear of leaves, debris,  
ice, and/or snow. The outside air path must be  
unrestricted while the appliance is in operation.  
2. The combustion air intake system must be of  
metal construction. It must permit zero-clearance  
to combustible materials, and contain a rodent  
screen.  
dO NOT CuT THROugH:  
fLOOR jOIsT, WaLL sTuds, OR CEILINg  
TRussEs.  
aNy suppORTINg MaTERIaL THaT WOuLd  
affECT THE sTRuCTuRaL INTEgRITy.  
3. The appliance must be secured to the mobile  
home structure by bolting it to the floor. There are  
brackets included, you'll need to secure with the  
proper length lag bolts.  
4. The appliance must be grounded to the metal  
framing of the mobile home  
CauTION  
NEvER dRaW OuTsIdE COMBusTION aIR fROM:  
WaLL, fLOOR OR CEILINg CavITy.  
ENCLOsEd spaCE suCH as aN aTTIC OR  
gaRagE  
5. All clearances to combustibles and floor protection  
requirements must be followed.  
6. Follow the vent manufacturer's instructions when  
installing in a mobile home.  
7. Installation shall be in accordance with the  
Manufactured Home and Safety Standard (HUD)  
CFR 3280, Part 24  
8. The appliance must never be installed in a room  
designated for sleeping.  
WaRNINg  
INsTaLLaTION MusT COMpLy WITH  
MaNufaCTuREd HOME aNd safETy sTaNdaRd  
(Hud), CfR 3280, paRT 24.  
This diagram shows the bracket that was used to  
bolt the stove to the pallet. Use at least two of these  
brackets for securing the appliance through the floor  
in a mobile home installation. The bracket will slip  
over the top of the leveling adjuster. The installer will  
need to determine and obtain the properly sized lag  
bolts.  
WaRNINg  
NEvER INsTaLL IN a ROOM INTENdEd fOR sLEEpINg.  
21  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
appliance set-up  
7
a. Outside air attachment  
B. Leveling the appliance  
Parts and Supplies Needed: 1 piece of metal flexible  
pipe, 4" X needed length. 1 Rodent Screen, and  
aluminum tape. Plus, a trim ring for finishing around  
the pipe on the inside wall.  
To adjust the leveling bolts, you must first loosen  
the locking nut. Turn the leveling bolt to the desired  
position, and tighten the locking nut against the cast  
iron leg.  
1. Determine an appropriate hole location, through  
the wall. Be sure there are no studs or other  
supporting members. Also ensure there are no  
electrical wires or plumbing contained within the  
wall.  
2. Make the hole through the exterior wall using a  
hole saw or reciprocating saw. You'll want the hole  
to be just slightly larger than the metal flex pipe.  
3. Attach the rodent screen to one end of the flex  
pipe, and insert it through the wall until the back  
of the screen cover is against the outside surface.  
4. Hold the flex pipe in place to make an accurate  
determination of the length needed. Cut the flex  
pipe to length.  
5. Slide the trim ring onto the flex for the inside wall  
portion.  
6. Slide the other end of the metal intake flex pipe  
into the stub on the rear of the Oakleaf and secure  
it with aluminum tape. This air intake will supply  
outside air for the secondary combustion within the  
FireDome.  
C. Optional Cooking grill  
The optional cooking grill #1-00-08121 installs easily  
in the top load opening of the Oakleaf.  
The grill handle (B) fits in the slots (C) on each side.  
To remove the handle, lower and turn.  
When installed, the grill hangs in the opening by the  
hooks (A).  
When grilling, you'll want to keep the fire size  
small and the bypass damper in the open position.  
Depending on the grilling being done, you may get  
grease dripping on the glass causing it to become  
dirty and obstructed. When you burn your next hot  
fire, the glass will likely clean itself.  
7. Secure the trim ring in place for finishing the inside  
wall area.  
8. Seal around the rodent screen on the exterior wall,  
using silicone caulking.  
a
CauTION  
B
NEvER dRaW OuTsIdE COMBusTION aIR fROM:  
WaLL, fLOOR OR CEILINg CavITy.  
ENCLOsEd spaCE suCH as aN aTTIC OR gaRagE  
a
C
C
a
Outside Air  
Attachment  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
d. Optional Blower Installation  
E. Optional Rear-vent Rear shield  
The optional blower kit #1-00-797032 installs easily to  
the rear of the Oakleaf.  
Hold the blower assembly into place and secure it with  
the two bolts provided. You'll need a 3/8" wrench or  
socket to tighten the bolts.  
Whenever a rear vent configuration is used, the upper  
rear heat shield, #1-00-797066 must be purchased  
and installed, to accomodate the flue collar. There  
are eight screws that secure the existing shield. You'll  
need to break away the tabbed portion of the lower  
shield flue cut-out. Remove the screws from the top-  
vent shield and install the rear vent shield in it's place.  
Height adjustment for blower use is done the same  
as with the top-vent shield in place. See D. Optional  
Blower Installation (above) for detailed instructions.  
If not installing the  
optional blower, the  
upper knockout will  
need to be removed.  
secure blower with one bolt on each end of the  
mounting plate.  
Notice: When installing the optional blower, the  
upper rear shield must be moved upward to create  
the air passage.  
shown with lower shield  
knockout removed.  
Loosen the eight screws to remove the rear shield.  
Raise the shield to the upper set of holes, re-install the  
shield, and tighten the screws.  
f. Optional Bottom Heat shield  
Part #1-00-797058 must be purchased and installed  
whenever the Oakleaf is installed on a protected  
combustible floor. The shield installs on four bolts that  
are protruding downward from the base of the stove  
body. Slide the shield under the stove from the back,  
as this is the only way it will fit. Lift into place guiding  
the bolts through the holes in the shield and secure  
with the nuts that are included with the shield.  
WaRNINg  
ROuTE pOWER CORdaWay fROM THEappLIaNCE.  
dO NOT RuN THE CORd uNdER OR IN fRONT Of  
THE appLIaNCE.  
Plug the blower into a properly grounded electrical  
outlet.  
You can turn the blower on at any time using the rocker  
switch on the rear of the blower housing. Setting the  
switch to "AUTO" will keep the blower off until there  
is a significant amount of heat from the stove. In this  
setting, the blower will also shut off when the stove  
cools. Keep the blower on low speed or off during low  
fires. As you get out of the low burn range, the speed  
can be set wherever desired, or kept off.  
23  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
Operating Instructions  
8
CauTION: approved for use with wood fuel only.  
The use of any other fuel will void the product  
warranty and may cause damage to the appliance  
and/or your home.  
CauTION:  
aLWays WEaR fIRE RETaRdaNT gLOvEs  
WHEN OpERaTINg THE sTOvE.  
safETy NOTICE  
If THIs appLIaNCE Is NOT pROpERLy INsTaLLEd,  
OpERaTEd aNd MaINTaINEd, a HOusE fIRE  
May REsuLT. fOR yOuR safETy, fOLLOW  
WaRNINg  
"NEvER usE gasOLINE, gasOLINE-TypE LaNTERN  
fuEL, kEROsENE, CHaRCOaL LIgHTER fLuId, OR  
sIMILaR LIquIds TO sTaRT OR "fREsHEN up " a  
fIRE IN THIs HEaTER. kEEp aLL suCH LIquIds  
WELL aWay fROM THE HEaTER WHILE IN usE".  
INsTaLLaTION dIRECTIONs.  
CONTaCT  
LOCaL BuILdINg OR fIRE OffICIaLs aBOuT  
REsTRICTIONs aNd INsTaLLaTION INspECTION  
REquIREMENTs IN yOuR aREa.  
dO NOT BuRN gaRBagE OR fLaMMaBLE LIquIds  
suCH as gasOLINE, NapTHa, OR ENgINE OIL.  
a. fuel specifications  
Select only dry, seasoned wood. Wood for burning  
should never be exposed to rain or extremely damp  
conditions. Hardwoods are favored because they are  
heavier and contain more heating capacity (BTU’s) per  
load than do softwoods. Fuel wood should be split and  
stored under cover for “seasoning” - at least a year is  
recommended. Your stove is not an incinerator - do  
not burn garbage, painted or treated wood, plastic, or  
other debris.  
Keep the area around the stove free from clutter.  
Keep all combustibles, including fuel, beyond the code-  
required clearance distance (48" or 1215 mm in the  
U.S., 1525 mm or 60" in Canada). Never store fuel  
in front of the stove where it could interfere with door  
operation, safe loading, and ash removal.  
B. general Operating Information  
1. draft  
Before you install and operate your Oakleaf  
wood stove, please read the entire contents of this  
manual. Pay particular attention to the explanation  
of draft and its effect on stove performance in  
the Installation section. By following the installation  
and operating guidelines, you will ensure proper draft  
and gain maximum efficiency and enjoyment from your  
stove.  
dO NOT aLTER THE pOsITION Of THE aNdIRONs.  
BuILdINg a fIRE TOO CLOsE TO THE gLass May  
CausE daMagE TO THE gLass, CREaTINgasERIOus  
RIsk Of fIRE aNd pROpERTy daMagE.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
2. doors  
Your stove has a large glass-paneled door for loading  
and fire viewing, a separate smaller door for removing  
ashes and a top loading door.  
C. The Combustion process  
Combustion in the Harman Oakleaf is precisely  
controlled and is best explained in two parts.  
Front Door  
During a wood fire, combustion air enters at the  
bottom front of the stove where it travels upward through  
channels at either side of the front door. From the  
manifold located above the front door, it is directed into  
the firebox as a sheet of air flowing between the glass  
and the wood. This concept helps to keep the glass  
clean, while providing the oxygen needed to sustain  
burning. This is what is known as "Primary Combustion".  
Additional air enters at the bottom rear of the stove  
body. Some of this air enters through holes in the rear  
bricks where it is used to revitalize the fire at the rear  
of the firebox. The remainder is delivered into the  
"Firedome" combustion package where the "Secondary  
Combustion", or re-burning of the smoke, occurs.  
During combustion, the burning of wood proceeds  
through several stages. The initial or evaporation stage  
is where the moisture in the wood is driven off in the  
form of steam. A second stage is where the volatile  
gases contained in the wood are released and burned.  
This represents most of the wood's heating capacity.  
The final stage is the charcoal stage where the charcoal  
burns the remaining heat content in the wood fuel. Ash  
remains after the burning is complete. Within the primary  
firebox two or more of these stages of combustion are  
occurring at once.  
Before opening, always check for wood, embers, or  
ash that may be ready to fall out of the door.  
To open the glass door, open the bypass damper  
first, then turn the handle clockwise and pull out; to  
close the door, push the door closed with the handle  
in the open position, then turn, counter-clockwise, to  
engage the latch.  
Ash Door  
To open the ash door, lift up the handle and pull out.  
Close the door by pushing in and pushing the handle  
all the way down.  
Top Load Door  
To open the top load door, open the bypass damper  
and then lift to open the top load door.  
All doors must be closed while the stove is in normal  
operation, and the gaskets routinely examined for wear  
and replaced when necessary. Good door seals are  
important for maintaining control of the stove. Never  
operate with the ash door open. Operating the stove with  
the ash door open, or with a door inadequately sealed,  
could create a serious overfiring condition (discussed  
later in this section).  
The glass used in your Oakleaf is manufactured  
to exact standards to withstand the high heat of the  
fire, but like all glass, it must be treated with common  
sense and care. Never abuse the glass by slamming  
the door shut or striking the glass with a heavy object.  
If the glass is broken or damaged, do not operate the  
stove until it has been replaced  
Always be sure to provide adequate ventillation  
to the room where the apliance is located, to prevent  
air starvation. In tight construction, consider installing  
outside air to the appliance.  
(See instructions in the Maintenance section.)  
3. grates  
EXHAUST STREAM  
The Harman Oakleaf's unique grate system  
consists of one flat bottom grate, and two front  
andirons. The bottom grate has slots which  
allow the ash to fall into the ash pan by passing  
a poker back and forth across the grate. The  
andirons keep the fuel from coming into direct  
contact with the glass, and keep hot coals and  
embers from spilling out while reloading. Never  
build a fire directly against the glass.  
The grates and andirons must remain  
in place at all times. do not tamper with  
or change the configuration of this grate  
system.  
SECONDARY AIR  
THRU BRICK  
SECONDARY AIR THRU  
RAMP BRICK  
SECONDARY AIR ENTERING  
EXHAUST STREAM  
PRIMARY AIR FLOW  
SECONDARY AIR FLOW  
PRIMARY & SECONDARY AIR FLOW  
25  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
For low burn, slide the air control to the left. For  
medium burns, use notches 1 to 2. Maximum heat is  
attained with the air control all the way to the right. Do  
not burn the stove continuously at the maximum setting.  
If maximum heat is required day after day, the stove is  
too small for the area you are trying to heat.  
If your wood is not seasoned long enough or is high  
in moisture content, you may need to adjust the primary  
air slightly higher to sustain a low burn rate with the  
cleanest possible exhaust.  
d. user Controls  
Two important controls - the damper bypass handle  
and the air control lever regulate the operation and  
output of the stove.  
To open the top or front loading door, you must open  
the damper bypass, or smoke will come in the room. In  
this mode of operation the combustion gases go directly  
from the main combustion chamber to the flue collar  
and exit into the chimney.  
NOTE: The bypass damper must be open for  
smokeless loading. Open the bypass damper by  
turning the handle clockwise while facing handle.  
E. Before your first fire  
Be sure the appliance is installed properly and  
that all safety requirements have been met.  
Pay particular attention to the clearances to  
combustibles, floor protection and the venting  
instructions.  
Test your smoke detector(s) and CO detector(s)  
to the specifications of the manufacturer.  
Double check that the ash pan and internal  
firebox are empty.  
Bypass Damper  
Bypass Damper  
Closed  
Open  
Be sure to read this entire manual.  
dO NOT OvERLOad THE appLIaNCE. dOORs MusT  
BE CLOsEd WHEN IN OpERaTION.  
f. Building and Maintaining a fire  
Begin with the bypass damper open, and the air  
control lever at the maximum setting, all the way to the  
right. Be sure the ash pan door is closed and latched.  
Start with a bed of crumpled paper and kindling sized  
about finger width; place several 1" - 2" (25mm - 50mm)  
split pieces of dry wood on top of the kindling, followed by  
a few 2" - 3" (50 mm - 80 mm) split pieces. Lay the wood  
in a crossed pattern to allow maximum air flow. Ignite  
thepaper and close the loading door(s).Allow this start-  
up fire to burn for a few minutes, keeping the bypass  
damper open. Add about five more pieces of wood in  
the 2 to 3 inch (50 - 80mm) size range, making sure  
that the fuel bed is all the way across the firebox and  
staggered to allow airflow. Close the door and allow this  
loading to burn a few minutes.  
Minimum  
Primary Air  
Maximum  
Primary Air  
Add increasingly larger pieces of wood to the fire until  
you have a thick bed of hot embers, approximately 2  
to 3 inches deep at the back of the grate and at least  
an inch deep at the front. You must have this charcoal  
bed established before you close the bypass damper.  
The air control lever is located directly below the load  
door. Sliding this lever allows you to vary the amount  
of air to the fire, creating a range of heat outputs. The  
lowest heat output setting is to the left, and the highest  
is to the right. The notches are provided as a reference  
for your comfortable heat settings. Do not, under any  
circumstances, alter the configuration or operation of  
the air control lever.  
Providing you have the charcoal bed described,  
close the bypass damper by pulling the handle toward  
the front of the stove.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
This will begin the highly efficient mode of operation  
where the exhaust gases get re-burned in the secondary  
combustion package. If you cannot achieve a charcoal  
bed within the first 15 to 20 minutes, your wood is likely  
too wet, and you may need to burn the fire longer and/  
or hotter to compensate for the extra energy needed to  
drive out the moisture. If, after five minutes of burning  
with the damper closed, smoke is visible coming from  
the chimney, you probably do not have the proper coal  
bed. Open the bypass damper and continue with the  
process until a significant coal bed is formed.  
ashes should be placed in a metal container  
with a tight fitting lid. The closed container of  
ashes should be placed on a noncombustible floor  
or on the ground, well away from all combustible  
materials, pending final disposal. If the ashes are  
disposed of by burial in soil or otherwise locally  
dispersed, they should be retained in the closed  
container until all cinders have thoroughly cooled.  
Never use the ash disposal container for other trash.  
Wood ash can be added to your garden or compost.  
CauTION  
Always remember to open the bypass damper when  
you are loading, this allows the exhaust gases to pass  
directly into the flue outlet and reduces the chance of  
smoke spillage into the room.  
THE sTOvE Is HOT WHILE IN OpERaTION. kEEp  
CHILdREN, CLOTHINg aNd fuRNITuRE aWay.  
CONTaCT May CausE skIN BuRNs.  
NEvER LEavE THE sTOvE uNaTTENdEd If EITHER  
THE asH OR LOad dOOR Is OpEN. OvERfIRINg  
May REsuLT.  
Reloading: Once you have prepared and maintained  
a thick charcoal bed, and the secondary combustion is  
established, you should be able to reload the stove at  
any time by simply opening the bypass damper, then  
the load door, adding fuel and closing the door then the  
damper. This depends on coal bed size, load size and  
moisture content of fuel.  
RIsk Of ExCEssIvE TEMpERaTuREs. kEEp asH  
dOOR CLOsEd duRINg fIRINg Of THE HEaTER.  
Avoid overfiring your stove. Overfiring is a potentially  
hazardous situation which can lead to overheating of  
combustible materials nearby, damage to the stove, and  
in extreme cases, cause a fire. Overfiring is caused by:  
1. Too much air flowing through the stove too quickly. 2.  
You may have positioned the primary air control lever  
too far to the right. 3. Inadvertently leaving the damper  
open or 4. Not keeping up with routine maintenance,  
such as checking door gaskets for wear.  
Overfiring results in excessive fuel consumption, and  
may cause parts of the stove or chimney connector to  
glow red. If you notice signs of overfiring, reduce the air  
supply to the fire, and review the Maintenance section  
in this manual.  
In the event of a chimney fire, call your local fire  
department; make sure everyone is safely out of the  
house. Reduce the air intake of the stove as much as  
possible using the air control lever; close the bypass  
damper to further restrict air flow. Do not throw water  
on the fire; this can cause stove damage and create  
an even more dangerous situation. Have your chimney  
professionally cleaned and inspected before resuming  
burning in your stove.  
Removing ashes: Before reloading, empty the ash  
pan (remember to close the ash door while emptying  
the pan). The ashes should be the coolest at this time.  
Remove ashes from the fire chamber periodically by  
raking a poker across the bottom grates.  
Excessive ash buildup can prevent proper venting  
of exhaust gases. Do not allow the ash pan to over-fill.  
Ash buildup between the ash pan and the bottom of  
the grate can cause the grate to overheat and wear  
out prematurely.  
The Oakleaf is designed to provide access to the ash  
pan without the need for opening the main door. Before  
opening the ash door  
and removing the ash  
pan, open the bypass  
damper.Wearingheavy  
protective gloves,  
open the ash door and  
remove the ash pan  
by pulling it forward by  
the handle. Close the  
As you begin to operate your stove at higher  
temperatures, you will notice a “hot” or unpleasant  
smell; this is just the paint going through the curing  
process, and will disappear after a few fires.  
ash door and damper  
bypass before taking  
the ashes outside for  
safe disposal.  
27  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
solid fuel burning spave heaters must be cleaned regularly,  
as soot, ash and creosote may accumulate.  
service & Maintenance  
9
seasonal cleaning  
a. Creosote- formation and Need for  
Removal;  
At least once per year, the stove, venting connectors  
and chimney should be thoroughly cleaned. If the areas  
are found to have an excessive build up of ash or  
creosote, it is recommended to increase the frequency  
of the cleaning. This will extend the life of the appliance  
and its components.Avacuum specifically designed for  
ash is preferred, however a standard shop-style vacuum  
with a HEPA filter may also work just fine.  
During cleaning, caution must be taken not to  
damage the white / gray colored ceramic combustion  
package in the rear of the firebox. When using a brush in  
the chimney or venting connector, the by-pass damper  
should be placed in the open position to help prevent  
ash, creosote or other debris from falling down onto  
and around the combustion package. This also protects  
the top of the combustion package from tool or brush  
damage and diverts most of the removed materials  
into the firebox for easy clean-up and removal. Once  
the venting system has been cleaned, remove the first  
section of connector pipe from the appliance flue collar.  
Carefully vacuum the ash and debris from around the  
sides and top of the combustion package.  
When wood is burned slowly, it produces tar and other  
organic vapors which combine with expelled moisture  
to form creosote. The creosote vapors condense in the  
relatively cool chimney flue of a slow burning fire. As a  
result, creosote residue accumulates on the flue lining.  
When ignited, this creosote makes an extremely hot  
fire. The chimney and chimney connector should be  
inspected at least once every two months during the  
heating season to determine if a creosote buildup has  
occurred. If creosote has accumulated, it should be  
removed to reduce the risk of a chimney fire.  
If you experience a chimney fire; Close the air control  
and bypass damper and notify the fire department.  
Do NOT apply water to the fire, in the firebox or in  
the chimney. Do not operate the appliance until the  
chimney and connector have been inspected and  
approved by a chimney professional.  
Do not burn any fuel other than wood, such as  
charcoal, which can cause increased carbon monoxide  
production or overfiring. Never use highly volatile  
substances in your stove, such as gasoline, which could  
cause an explosion.  
When solid fuels are burned completely, they produce  
water and carbon dioxide. However, in long slow burns,  
a substantial amount of carbon monoxide may be  
produced. If allowed to build up, carbon monoxide  
(which is odorless) can prove fatally poisonous. Proper  
ventilation and draft will prevent this from happening.  
If you smell smoke, turn up the air control lever setting,  
and thoroughly ventilate your dwelling. During future  
burns, be careful not to overload the stove with fuel, so  
you will not be tempted to constantly operate at a low  
air control setting.  
The shoe brick must be removed to allow vacuum  
access for cleaning the front portion of the combustion  
package.  
Always use caution when refueling or when  
vacuuming the firebox and combustion package. Some  
users have damaged their combustion package with  
vacuum cleaner tools, and fire pokers.  
CAuTion: ALwAysweArFire-resisTAnTgLoves  
To operATe The sTove. TheAir ConTroLis hoT  
whiLe in operATion.  
Other causes of poor ventilation or draft are icing,  
exhaust fans, a blocked outside air inlet, and room  
air starvation. If your stove is sluggish and you get  
occasional odor, check these possibilities and increase  
the air flow in your home.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
2. door glass  
B. general Maintenance procedures  
1. ash Removal  
frequency: As needed / Weekly  
By: User  
frequency: As needed / Every day or two  
By: User  
Whenever the view of the fire is obstructed, or weekly,  
clean the glass using a soft cloth dampened with  
standard household glass cleaner.  
Wear Leather gloves To prevent skin Burns!  
Never spray glass cleaner directly onto hot glass.  
apply the cleaner to the cloth then wipe the glass.  
Open the ash removal door by lifting upward on the  
latch handle, then swing the door open. Pull the ash  
pan out of the firebox, using the lip on the front of the  
pan. Once the ash pan is removed from the stove, you  
can flip the carry handle up for convenience.  
If removing ashes while a fire is burning, close and  
latch the ash door while disposing of the ashes.  
DO NOT leave the appliance unattended with the ash  
door open.  
fly-ash allowed to accumulate on the glass may  
lead to permanent fogging or "crazing" of the  
glass.  
Inspect the glass and sealing gasket. Replace gasket  
as needed. Do not operate the stove with a broken  
glass. Replacement glass, which is ceramic glass,  
should be obtained only through your Harman dealer.  
To replace a broken glass; first be sure to carefully  
remove the broken glass and any remaining shards or  
pieces. With the door laying on a flat surface, lay the  
gasketted glass panel onto the door and be sure it is  
properly fitted into the channel. Lay the glass retainer  
clips in place near each corner, and secure them using  
the 3/8" screws. Be sure to tighten each screw equally  
so you don't create a pressure point on the glass.  
CAuTion: never use AbrAsive mATeriALs on  
The gLAss.  
Glass Retainers  
Glass Panel  
ashes must be placed in a metal container with  
a tight fitting lid. The closed container of ashes  
should be placed on a non-combustible floor or  
on the ground, well away from all combustible  
materials, pending final disposal. If the ashes are  
disposed of by burial in soil or otherwise locally  
dispersed, they should be retained in the closed  
container until all cinders have thoroughly cooled.  
do not use the ash container for other debris or  
yard waste.  
Glass Retainer  
screws  
Gasket  
Door Frame  
WaRNINg: dO NOT aBusE gLass By sTRIkINg  
OR sLaMMINg THE dOOR CLOsEd. THIs TypE Of  
BREakagE Is NOT COvEREd By THE pROduCT  
WaRRaNTy.  
29  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
3. firebox  
5. Chimney Connector  
frequency: As necessary / Yearly  
By: User  
frequency: As necessary / Yearly  
By: Qualified Service Technician / User  
Cleaning the firebox and internal heat exchange  
surfaces is recommended to maintain thermal  
efficiency. Depending on the quality and quantity  
of fuel being used, you may want to perform this  
cleaning monthly.  
At the end of the burn season, brush and clean all  
sections of chimney connector pipe. Some owners  
remove the chimney connector for the off season.  
Any ashes left in the connector pipe will actually draw  
moisture which promotes rust. This is why it is very  
important to clean all ashes at the end of the heating  
season.  
When cleaning the chimney connector above the  
appliance, keep the bypass damper in the open  
position. This will keep any loosened material from  
falling into the Firedome combustion chamber.  
Be sure to clean these areas thoroughly at the end of  
the heating season.  
Brush and vacuum all internal surfaces at the end  
of the heating season. Ashes will draw moisture and  
may promote rust formation.  
4. Blower- If installed  
Chimney  
Connector  
frequency: As necessary / Yearly  
By: User  
The fan on the blower will collect debris over time.  
Any accumulation must be removed to maintain  
proper operation.  
To clean blower;  
Disconnect power cord before servicing.  
Remove the two bolts that hold the blower in  
place.  
6. Chimney  
Use a vacuum and/or brush to remove all dust  
and pet hair from the blower wheel.  
Reinstall the blower and tighten the two bolts  
securely.  
frequency: As necessary / Yearly  
By: Qualified Service Technician / Chimney  
Sweep  
The entire chimney should be professionally cleaned  
at least once yearly. It is best to have this done at  
the end of the heating season to be sure all ash is  
removed. You'll also want to inspect the condition of  
the chimney prior to using the appliance, to be sure  
there are no bird or animal nests.  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
Reference Materials  
10  
1
2
31  
Save These Instructions  
3-90-798  
Dry Seasoned Wood Only!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
service parts  
Oakleaf  
Beginning Manufacturing date: sept 2010  
Ending Manufacturing date: active  
Cast Iron Wood stove  
1-90-797000-1 (Black),  
((sept 2010 thru june 2011)--1-90-797000-2 (Charcoal), 1-90-797000-3 (goldenfire))  
3
1
4
2
5
10  
7
11  
6
9
28  
27  
12  
8
13  
14  
25  
23  
22  
21  
15  
26  
16  
24  
18  
19  
17  
20  
part number list on following page.  
12/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
service parts  
Oakleaf  
Beginning Manufacturing date: sept 2010  
Ending Manufacturing date: active  
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement  
parts for your appliance please provide model number and serial number. All parts listed  
in this manual may be ordered from an authorized dealer.  
stocked  
at depot  
ITEM  
dEsCRIpTION  
COMMENTs  
paRT NuMBER  
2-00-797053P  
1-00-797066  
1-10-249109  
1-00-00999  
Heat Shield-Upper Top  
Heat Shield-Upper Rear  
Oak Flue Collar Cover w/Gasket  
Gasket-3/8 Round LDPSA  
Oak Flue Collar  
1
2
10 Ft  
y
y
3
4
4-00-249108D  
1-00-2312  
Gasket-1/4 Round PSA  
Oak Top Load Door  
15 FT  
3-00-249115P  
1-00-797067  
1-00-37525  
Load Door Handle Kit  
Gasket-3/8 Round LD, Top Load Door  
Inside Plate-Left w/Gasket  
Gasket-1/4 Round PSA  
Oakleaf Package  
5
6
5 Ft  
y
1-10-797104  
1-00-2312  
15 Ft  
15 FT  
15 FT  
y
y
y
y
y
y
y
y
y
y
y
y
y
y
7
8
3-40-797022  
1-00-2312  
Gasket-1/4 Round PSA  
Ramp Assembly w/Gsket  
Gasket-1/4 Round PSA  
Brick Clip Set  
1-10-797109  
1-00-2312  
9
1-00-249153  
1-10-797103A  
1-00-249142  
3-50-00500S  
4-00-797113  
1-10-797036W  
1-00-2312  
10  
Damper Frame Assembly  
Damper Adjustment Kit  
Damper Handle  
Damper Plate  
Damper Rod  
Gasket-1/4 Round PSA, Damper Plate  
Gasket-3/8 Round LD, Damper Frame  
Screw-SSSKN5/16-18 X 3/8  
Side Left  
15 FT  
5 Ft  
1-00-37525  
Pkg of 25  
3-30-2004-25  
3-00-797107  
1-00-37525  
11  
Gasket-3/8 Round LD  
Oak Andiron, Painted  
Brick Set, 9" x 4 1/2" x 1 1/4"  
Grate  
5 Ft  
y
y
y
y
12  
13  
14  
15  
16  
17  
3-00-249101P  
1-00-900450125  
2-00-797023B  
1-10-797010  
1-10-797013  
1-10-797110  
1-00-37525  
Pkg of 7  
Airslide  
Airslide shaft  
Ash Door Assembly  
Gasket-3/8 Round LD  
Wooden Knob, Ash Door  
5 Ft  
y
3-40-08746-3  
Additional service part numbers appear on following page.  
12/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
service parts  
Oakleaf  
Beginning Manufacturing date: sept 2010  
Ending Manufacturing date: active  
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement  
parts for your appliance please provide model number and serial number. All parts listed  
in this manual may be ordered from an authorized dealer.  
stocked  
at depot  
ITEM  
dEsCRIpTION  
Door Assembly, Front  
COMMENTs  
paRT NuMBER  
1-10-797108  
3-40-797025  
1-00-00249  
1-00-2312  
18  
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
Door Glass  
Handle Assembly  
Gasket-1/4 Round PSA, Glass Gasket  
Gasket-3/8 Round LD, Door Gasket  
Glass Clips and Hardware  
15 FT  
5 Ft  
1-00-37525  
1-00-249140  
1-10-797026  
4-00-249100P  
3-30-1134-50  
3-30-4001-25  
3-30-8005-100  
3-40-797020  
1-00-2312  
19  
20  
Ash Pan  
Leg Painted  
Screw-HCS 3/8-16 X 1 Z  
Pkg of 50  
Pkg of 25  
Pkg of 100  
Bolt-CB 5/16-18 X 2 Z  
Nut-FHN 5/16-18 Z 5  
21  
22  
23  
Center Brick  
Gasket-1/4 Round PSA  
Brick 12 X 6 X 1-1/4  
Brick Clip  
15 FT  
1 Set  
3-40-86125  
1-00-249172  
1-10-797034  
1-00-10050  
1-00-2312  
Center Seal Plate, w/Gasket  
Gasket 1-1/2X3/8 BULBPSA, Center Plate  
Gasket-1/4 Round PSA  
Side Right  
5 Ft  
y
y
15 FT  
24  
25  
26  
3-00-797111  
1-00-37525  
1-10-797112  
1-00-2312  
Gasket-3/8 Round LD  
Inside Plate, Right, w/Gasket  
Gasket-1/4 Round PSA  
Blower Assembly (Option)  
Blower  
5 Ft  
y
y
15 FT  
1-00-797032  
1-00-7000537  
3-20-06652  
3-20-408412  
1-10-797045  
2-00-797033W  
y
y
y
Power Cord  
Snap Disc  
27  
28  
Adapter, Pipe  
Heat Shield, Lower Rear  
12/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufactured by: HarMan HOMe HeatInG MOdel: Oakleaf  
u.S. envIrOMental PrOtectIOn aGency  
Meets EPA particulate matter (smoke) control requirements for noncatalytic  
wood heaters built on or after July 1, 1990.  
SMOke  
0
Grams Per Hour  
8.5  
effIcIency  
50%  
60%  
70%  
80%  
90%  
100%  
Wood heaters with higher efficiencies cost less to operate.  
Heat OutPut  
9,600 to 24,700 btu  
use this to choose the right size appliance for your needs.  
aSk dealer fOr HelP.  
This wood heater will achieve low smoke output and high efficiency only if  
properly operated and maintained. See owner’s manual.  
#3-90-799  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hearth & Home Technologies Inc.  
LIMITED LIFETIME WARRANTY  
Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for  
HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.  
WARRANTY COVERAGE:  
HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership  
of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance  
will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo-  
nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period,  
HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its  
obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product  
itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty  
is subject to conditions, exclusions and limitations as described below.  
WARRANTY PERIOD:  
Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage  
begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent,  
authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months  
following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for  
parts and labor for covered components is produced in the following table.  
The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for  
gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These  
time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.  
Warranty Period  
Parts Labor  
HHT Manufactured Appliances and Venting  
EPA  
Components Covered  
Gas  
X
Wood Pellet  
Coal Electric Venting  
Wood  
All parts and material except as  
covered by Conditions,  
Exclusions, and Limitations  
listed  
1 Year  
X
X
X
X
X
X
Igniters, electronic components,  
and glass  
X
X
X
X
X
X
2 years  
X
X
X
Factory-installed blowers  
Molded refractory panels  
3 years  
X
X
Firepots and burnpots  
Castings and baffles  
5 years 1 year  
X
X
Manifold tubes,  
HHT chimney and termination  
7 years 3 years  
X
X
10  
1 year  
years  
X
X
X
Burners, logs and refractory  
Firebox and heat exchanger  
Limited  
3 years  
Lifetime  
X
X
X
X
X
X
X
X
All replacement parts  
beyond warranty period  
90 Days  
X
X
See conditions, exclusions, and limitations on next page.  
4021-645C 12-29-10  
Page 1 of 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY CONDITIONS:  
This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of  
HHT authorized dealers is available on the HHT branded websites.  
This warranty is only valid while the HHT appliance remains at the site of original installation.  
Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact  
the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service  
from a dealer other than the dealer from whom you originally purchased the product.  
Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges  
for parts are not covered by this warranty.  
WARRANTY EXCLUSIONS:  
This warranty does not cover the following:  
Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and  
exterior surface finishes may occur. This is not a flaw and is not covered under warranty.  
Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items,  
or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.  
Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts  
include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, light bulbs, batteries and the discolor-  
ation of glass.  
Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com-  
plaints related to this noise are not covered by this warranty.  
Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation  
instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to  
install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera-  
tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/  
incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting  
caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or  
forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7)  
installation or use of components not supplied with the appliance or any other components not expressly authorized  
and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing;  
and/or (9) interruptions or fluctuations of electrical power supply to the appliance.  
Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.  
Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.  
HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa-  
tion is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consider-  
ation must be given to appliance location and configuration, environmental conditions, insulation and air tightness of  
the structure.  
This warranty is void if:  
The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging  
chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling,  
cracking and discoloration of steel or enamel finishes.  
The appliance is subjected to prolonged periods of dampness or condensation.  
There is any damage to the appliance or other components due to water or weather damage which is the result of, but  
not limited to, improper chimney or venting installation.  
LIMITATIONS OF LIABILITY:  
The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or  
implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no  
event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states  
do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you.  
This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO  
THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY  
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE  
EXPRESSED WARRANTY SPECIFIED ABOVE.  
4021-645C 12-29-10  
Page 2 of 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Oakleaf Woodburning stove  
service & Maintenance Log  
Date Of Service  
Performed By  
Description Of Service  
Dry Seasoned Wood Only!  
3-90-798  
Save These Instructions  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
At Harman, we build each product to a standard, not a price.  
This powerful heating appliance boasts uncompromising  
attention to detail and helps preserve our planet by using  
environmentally responsible fuels.  
(Signature of Boxer)  
Your premium quality hearth product designed and assembled  
by the experienced and skilled members at Harman in Halifax,  
PA, USA.  
Proudly Printed On 100% Recycled Paper  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grundig Flat Panel Television PHDQ 2002 BC User Manual
Haier TV Receiver 29FA18 User Manual
Hamilton Beach Electric Grill 840081800 User Manual
HANNspree Flat Panel Television LT01 10U1 User Manual
Hasbro Robotics 81120 81060 User Manual
HP Hewlett Packard Printer 24SII User Manual
Hypertec Printer Fastprint Multiprotocol Ethernet Fast Ethernet Print Server User Manual
IBM Laptop I 1700 User Manual
IBM Printer 1552 User Manual
Ice O Matic Ice Maker B Series User Manual