HP Hewlett Packard Scanner 5400c Series 4400c Series User Manual |
hp scanjet 4400c series
and 5400c series scanners
user’s manual
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Back to TOC
© Copyright Hewlett-Packard Company 2001
The information contained in this document is subject to change
without notice.
All rights reserved. Reproduction, adaptation, or translation without
prior written permission is prohibited, except as allowed under
copyright laws.
Hewlett-Packard makes no warranty of any kind with respect to this
information. HEWLETT-PACKARD SPECIFICALLY DISCLAIMS THE
IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE.
Hewlett-Packard shall not be liable for any direct, indirect, incidental,
consequential, or other damage alleged in connection with the
furnishing or use of this information.
Adobe and Adobe Photoshop are trademarks of Adobe Systems
Incorporated. Energy Star® is a U.S. registered service mark of the
United States Environmental Protection Agency. Microsoft and Hotmail
are U.S. registered trademarks of Microsoft Corporation.
NOTICE TO U.S. GOVERNMENT
USERS: RESTRICTED RIGHTS COMMERCIAL COMPUTER
SOFTWARE: “Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph (c) (1) (ii) of the
Rights in Technical Data Clause at DFARS 52.227-7013.”
All other products mentioned herein may be trademarks of their
respective companies.
Material scanned by this product may be protected by governmental
laws and other regulations, such as copyright laws. The customer is
solely responsible for complying with all such laws and regulations.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
3
Front panel and accessories comparisons
The following tables provide information about the HP Scanjet 4400c
series and 5400c series scanners, including descriptions of the buttons
available on the front panels and the accessories you can use with
these scanners.
To find information about your scanner, see the following tables:
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Back to TOC
HP Scanjet 4400c
Supported
Included on scanner
or in box
Feature
a
accessory
Copy button
Photo Reprint button
Scan To button
E-mail button
Power Save button
USB cable
HP Scanjet Transparency Adapter
(XPA)
a. Supported accessories include accessories that are not boxed with the
scanner, but can be purchased separately.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
5
HP Scanjet 4470c
Supported
Included on scanner
or in box
Supported
Included on scanner
or in box
Feature
Feature
a
a
accessory
accessory
More Options button
Copy button
Cancel button
Color/black & white copy and
select number of copies buttons
Two-digit LCD
USB cable
Photo Reprint button
Scan To button
HP Scanjet Transparency Adapter
(XPA)
E-mail button
Share-to-Web button
a. Supported accessories include accessories that are not boxed with the
scanner, but can be purchased separately.
Power Save button
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Back to TOC
HP Scanjet 5400c
Supported
Included on scanner
or in box
Supported
Included on scanner
or in box
Feature
Feature
a
a
accessory
accessory
Power Save button
Copy button
More Options button
Cancel button
Color/black & white copy and
select number of copies buttons
Photo Reprint button
Scan To button
Two-digit LCD
Scanner lock
E-mail button
USB cable
Share-to-Web button
b
Parallel cable
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
7
Supported
Included on scanner
or in box
Feature
a
accessory
HP Scanjet Transparency Adapter
(XPA)
HP Scanjet Automatic Document
Feeder (ADF)
a. Supported accessories include accessories that are not boxed with the
scanner, but can be purchased separately.
b. The parallel cable shipped with the scanner is for computers that use
Microsoft Windows. For Macintosh computers, use the USB cable. For
more information, see the Setup and Support Guide.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Back to TOC
HP Scanjet 5470c
Supported
Included on scanner
or in box
Supported
Included on scanner
or in box
Feature
Feature
a
a
accessory
accessory
Share-to-Web button
Copy button
Power Save button
More Options button
Cancel button
Color/black & white copy and
select number of copies buttons
Photo Reprint button
Scan To button
b
(with Speed Destinations )
16-character LCD
Scanner lock
Select Destination button
E-mail button
USB cable
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
9
Supported
Included on scanner
or in box
Feature
a
accessory
c
Parallel cable
HP Scanjet Transparency Adapter
(XPA)
HP Scanjet Automatic Document
Feeder (ADF)
a. Supported accessories include accessories that are not boxed with the
scanner, but can be purchased separately.
b. Speed Destinations are scanner button options available in the HP
Scanjet Controls control panel. See "Changing settings for Speed
c. The parallel cable shipped with the scanner is for computers that use
Microsoft Windows. For Macintosh computers, use the USB cable. For
more information, see the Setup and Support Guide.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Back to TOC
HP Scanjet 5490c
Supported
Included on scanner
or in box
Supported
Included on scanner
or in box
Feature
Feature
a
a
accessory
accessory
Share-to-Web button
Copy button
Power Save button
More Options button
Cancel button
Color/black & white copy and
select number of copies buttons
Photo Reprint button
Scan To button
b
(with Speed Destinations )
16-character LCD
Scanner lock
Select Destination button
E-mail button
USB cable
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
11
Supported
Included on scanner
or in box
Feature
a
accessory
c
Parallel cable
HP Scanjet Transparency Adapter
(XPA)
HP Scanjet Automatic Document
Feeder (ADF)
a. Supported accessories include accessories that are not boxed with the
scanner, but can be purchased separately.
b. Speed Destinations are scanner button options available in the HP
Scanjet Controls control panel. See "Changing settings for Speed
c. The parallel cable shipped with the scanner is for computers that use
Microsoft Windows. For Macintosh computers, use the USB cable. For
more information, see the Setup and Support Guide.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Back to TOC
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Back to TOC
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Getting started
15
Getting started
1
This section contains the basics to help you get started with your new
HP Scanjet scanner. From here, you can learn about viewing the
product tour, preparing items before you scan them, and choosing
which scanning method to use.
Viewing the product tour
The product tour is a fast and easy way to explore the capabilities of
the scanner and see some interesting ways you can use the scanner
to meet your needs. The product tour, which only takes three minutes,
begins automatically when you start the HP Precisionscan Pro
software for the first time.
Printing this information
To view the tour at other times: In the HP Scanning Software folder,
double-click Product Tour.
To print this PDF manual, use the Print command on the File menu.
Print the whole document, or print only the chapters or topics you want
according to their page numbers. See the table of contents for page
numbers of topics.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Getting started
Back to TOC
Using another program
Where do I start?
Start scanning from within another program when:
You can start scanning from one of these places:
l
l
You want to bring a scanned item into an open program, such as
your word-processing program.
l
l
l
l
Scanner buttons
HP Precisionscan Pro software
Another program
The program in which you are working is compliant with TWAIN or
the HP Scanjet Plug-in (which is an Adobe® Photoshop® plug-in).
A program is compliant if a command such as Acquire Image or
From Scanner appears on a menu such as the File menu.
If you are unsure whether your program complies with TWAIN
standards or supports Photoshop plug-ins—or you do not know the
command for inserting a scanned item, see the documentation for
the program.
HP Scanjet Copy Utility
Where you start depends on what you want to do with the scan and on
your own preferences.
Using the scanner buttons
Use the scanner buttons, which are shortcuts, when:
Using the HP Scanjet Copy Utility
l
l
l
You want to start at the scanner.
You want to scan quickly without making changes.
Use the HP Scanjet Copy Utility when you need to make standard
copy adjustments, such as reducing or enlarging, or lightening or
darkening. You can also choose a printer other than the default.
You want to scan an item using the default settings optimized for
the destination you choose.
To start the utility: in the HP Scanning Software folder, double-click
HP Scanjet Copy Utility. For help using the utility, move the pointer
over the button or option to find more information about the feature.
Using the HP Precisionscan Pro software
Use the HP Precisionscan Pro software when:
l
l
You want to view or change a scanned image before you send it.
Changes might include resolution, cropping, or resizing.
You want to send to a destination, such as a desktop publishing
program, but there is no button on the scanner for that destination.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Getting started
17
Items for the ADF
Selecting and preparing items
The HP Scanjet Automatic Document Feeder (ADF), which is a fast,
convenient way to scan multiple-page items, is included or supported
on some scanner models. See "Front panel and accessories
comparisons" on page 3. The ADF accepts items that meet the
following specifications:
Before placing items in the scanner, follow these guidelines for
selecting and preparing them to prevent damage to the items and the
scanner.
CAUTION
Improper placement and scanning can damage the
items and the scanner.
l
l
l
items on standard Letter-, A4-, and Legal-size paper
items consisting of as many as 25 unbound pages
Items for the scanner glass
items ranging in size from 88.9 by 127 mm (3.5 by 5 inches) to
215.9 by 355.6 mm (8.5 by 14 inches)
The scanner glass can scan the widest range of items, including:
l
l
items ranging in weight from 60 to 90 g/m2 (16 to 24 lb)
l
l
l
paper items
items that are square or rectangular and in good condition (not
fragile or worn)
news clippings, receipts, and business cards
items on all weights of media, including media lighter than 60 g/m2
(16 lb) or heavier than 105 g/m2 (28 lb)
l
l
items that are free of tears, perforations, or punch holes
items that are free of wet glue, correction fluid, or ink
l
l
l
l
l
gum-backed paper
Avoid multipart forms with carbon pages, transparencies, magazine
pages, gum-backed pages, and light “onionskin” pages.
multipart forms with carbon pages
old or worn photographs or documents
items containing tears, perforations, punch holes, wrinkles, or curls
Before placing an item in the ADF, prepare the item by doing the
following:
flatter, three-dimensional items such as fabric, pages in books, and
paper with texture
l
l
Remove curls or wrinkles.
Remove staples, paper clips, paper sticky notes, and any other
materials from items.
CAUTION
Avoid placing items with sharp edges on the scanner
glass. Doing so can damage the scanner.
If your item does not meet these guidelines or you cannot prepare it as
stated, use the scanner glass.
Before placing an item on the scanner glass, make sure the item is free
of wet glue, correction fluid, or other contaminating substances.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Getting started
Back to TOC
Items for the XPA
The HP Scanjet Transparency Adapter (XPA) is included with some
scanner models or can be ordered. Use the XPA and its templates to
scan:
l
l
35 mm photographic negatives
35 mm slides
Because these items are easily damaged, handle them only by their
edges.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Getting started
19
Completing your first scan
1
2
3
Choose an item to scan, such as a page from a magazine.
This section shows you how to take the same item and scan to print
using the two primary scanning methods:
l
l
Scanner buttons
HP Precisionscan Pro software
Before scanning, place the item in the scanner.
Place the item face down on the scanner glass and close the lid.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
Getting started
Back to TOC
1
2
On the scanner, press the Copy button (
). The scanner scans
the item using settings optimized for printing this type of item and
then prints the item to the default printer.
Copy button
3
If the scan does not work, or you have difficulty with this process,
If you have not already scanned using the HP Precisionscan Pro
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Getting started
21
4
Experiment with the image. Change the output type or make other
adjustments.
1
2
5
6
When you finish: On the Scan menu, click Print.
Select any printer options you want and click OK. The scanner
performs a final scan including your changes, and the scanned
image prints.
With the item loaded, press the Scan To button (
) on the
scanner. The scanner scans the item to the HP Precisionscan Pro
software, choosing the best settings for this type of item.
7
If the scan does not work, or you have difficulty with this process,
3
When the scanned image appears in the preview window of the
software, draw a selection border around the image or portion of
the image you want. To do so, click on one corner of the area you
want, and while holding down the mouse button, drag the cursor to
the opposite corner. Release the mouse button to complete the
border.
Selection
border
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Getting started
Back to TOC
Frequently asked questions
You can reduce the time it takes to scan an item by scanning in black
and white when the original is one of the following:
This section contains answers to some questions frequently asked
about scanning.
l
l
a black-and-white photograph or drawing
a color photo or drawing, but you want a black-and-white image to
appear on the computer screen
l
an item that contains only text
Based on the scanned item, the software automatically chooses
optimal values for these settings:
Another option is to reduce file size. See "How can I reduce the file
Print color originals as black and white by selecting the Black & White
l
l
l
l
l
output type
option on the front panel and pressing the Copy button (
). Or, in
resolution
the HP Precisionscan Pro software, choose the Grayscale or Black &
White output types before your final scan (after the scanner completes
sharpening
exposure (midtones, highlights, and shadows)
color (hue and saturation or black & white threshold)
In the HP Scanjet Controls control panel, select the Faster Scan
setting on the Lamp tab. When selected, this setting allows you to set
a time for the scanner to turn on. After this time, the scanner lamp and
the XPA light source (if connected) stay on for ten hours and then turn
Usually, the values the software selects provide optimal results.
However, you can change these values in the HP Precisionscan Pro
software.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Getting started
23
To reduce file size:
Use Zoom In to view an area of the scanned image close up. Use
Zoom Out to return to the original view of the image.
l
Save files using a compressed format, such as TIFF compressed
or JPEG.
The zoom commands do not change the final size of your scan; they
just give you a different view on a monitor. To reduce or enlarge the
size of the final scan, use the Resize command on the Tools menu.
l
Avoid using the True Color output type unless necessary. This
output type offers exceptional quality for color photos or drawings,
but it also creates large file sizes.
l
l
Set the resolution no higher than necessary. Generally, the
resolution the software automatically sets provides the best
balance between image quality and small file size.
When you scan an item containing text, you can use the text either as
a scanned image, such as a fax or photo archive, or as text you can
edit.
For photos, significantly reduce file size by cropping the photo to
select just one area as the final scanned image. Or, resize the
entire photo to smaller dimensions.
To have the optical character recognition (OCR) software make the
text editable automatically and send the text to a supported word-
processing program, press the Scan To button (
). In the
HP Precisionscan Pro software, choose Scan To from the Scan menu.
Then choose Text File from the Destination pull-down menu and click
Scan.
The HP Precisionscan Pro software sets the resolution for you based
on the original document attributes. In almost all cases, you get the
best results and the smallest file size using the default resolution.
Tip
Perform a spell-check after you have successfully
scanned your text to a word-processing program.
A computer screen usually displays images at 72 to 75 pixels per inch
(PPI). Print resolution is usually higher. Screens also use fewer colors
to display an image. Even if an image looks incorrect on the screen, it
might print the way you want.
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Getting started
Back to TOC
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
25
Scanning from scanner buttons
2
The scanner buttons provide an easy way to scan items directly to
destinations using settings optimized for the destination you choose.
You do not view or change scanned images before they go to the
destination.
To view or change images, scan to the HP Precisionscan Pro software
using the Scan To button (
). For more help viewing or changing
Tip
You can change the default settings for buttons on
the scanner. See "Configuring scanner buttons" on
Download from Www.Somanuals.com. All Manuals Search And Download.
26
Scanning from scanner buttons
Back to TOC
Overview of scanner buttons
For a list of buttons available on your scanner, see "Front panel and accessories comparisons" on page 3.
Scan To
Scan to the HP Precisionscan Pro software. View the image or make adjustments, such as changing
resolution or resizing. If your scanner also has a Select Destination button (some models only) next to the
Scan To button, you can select and scan to other programs on your computer.
Select Destination (some models only)
Press this button up or down to choose a program, then press the Scan To button. The Scan To button scans
the item using settings optimized for that destination and sends the scan to that destination.
Share-to-Web (some models only)
Scan a photo and send it to the HP Share-to-Web Wizard on your computer. The HP Share-to-Web Wizard
uploads the image to a website.
Photo Reprint
Scan a photo and send it to the photo printing software for printing multiple photos on one page or for
creating photo album pages.
E-mail
Scan using settings optimized for e-mail. The e-mail program window automatically launches so you can
compose your message. The scanned image becomes a file attachment in the new e-mail message. If you
do not have a supported e-mail program, this button allows you to save the scanned image as a file.
Copy
Print copies using settings optimized for printing. At the computer, you can press +.
(COMMAND KEY+PERIOD) to cancel the scan.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from scanner buttons
27
Number of copies (some models only)
Choose the number of copies before pressing Copy. The liquid crystal display (LCD) shows the number of
copies selected.
Color/Black & White copy (some models only)
Choose the color or black and white setting before pressing Copy to ensure the best settings are used. Only
use color copy if you are printing to a color printer and want a color copy. The light adjacent to the currently
selected choice is lit.
More Options (some models only)
Open the HP Scanjet Controls control panel to change settings, such as resolution, for some buttons on the
scanner. If your scanner does not have this button, open the HP Scanjet Controls control panel from your
Cancel (some models only)
Cancel a scan while the scanner is in the process of scanning, or cancel a series of scans from the HP
Scanjet Automatic Document Feeder (ADF).
Power Save
Puts the scanner in an energy-conservation mode. The scanner lamp and a small indicator light near the
Power Save button turn off. To use the scanner, press any button on the front panel of the scanner or start a
scan from the computer. The scan begins when the lamp is ready.
Download from Www.Somanuals.com. All Manuals Search And Download.
28
Scanning from scanner buttons
Back to TOC
Scanning to the HP Precisionscan Pro software
Scanning quickly with scanner buttons
When you use the Scan To button (
), you send directly to the HP
Use the scanner buttons to scan quickly to a destination using settings
optimized for that destination. A destination is a printer, file, or another
program, such as your e-mail or word-processing program.
Precisionscan Pro software. Using the HP Precisionscan Pro software,
you can preview scanned images and make changes to the images
before you send them to a destination or file them.
Tip
When scanning multiple pages without using an
ADF, the computer might prompt you for another
page. The HP Precisionscan Pro software adds
these pages to the current file. (To turn this feature
off, see "Changing settings for buttons" on
page 35.)
1
If your scanner has a 16-character LCD, make sure that either
Powersave On, Ready, or HP Precisionscan appear on the LCD.
Note:
If another program name appears in the LCD, press the
Select Destination button ( ) up or down until
HP Precisionscan is listed in the scanner’s LCD.
If you are scanning slides or negatives using the HP Scanjet
Transparency Adapter (XPA), you must scan from the HP
2
3
Close the HP Scanjet Copy Utility and the HP Scanjet Controls
control panel if they are open on your computer.
Place the original face down on the scanner glass and close the lid.
4
5
Press the Scan To button on the front panel of the scanner.
Your computer opens the HP Precisionscan Pro software. A
preview of the scan appears in the Precisionscan Pro software
window.
For more information, see "Scanning from HP Precisionscan Pro" on
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from scanner buttons
29
4
5
Press the Scan To button on the front panel of the scanner.
Scanning to another program
The item is scanned using settings optimized for the program you
selected. The program launches and the scan is sent to the
program.
On some models, you can select from a list of destinations (including
the HP Precisionscan Pro software) on the front panel LCD, then scan
directly to the selected destination.
Note:
For information about selecting and updating the
destinations for scanner buttons, see "Changing
When you select a program other than HP Precisionscan Pro using the
Select Destination button (
), the scanner will automatically use
settings optimized for the destination you choose. You do not view or
change scanned images before they go to the destination.
Tip
If your scanner does not have a Select Destination
button next to the Scan To button, you can scan to
other programs through the HP Precisionscan Pro
1
2
3
Close the HP Precisionscan Pro software, the HP Scanjet Copy
Utility, and the HP Scanjet Controls control panel if they are open
on your computer.
Place the original face down on the scanner glass and close the lid.
If your scanner has a Select Destination button next to the Scan To
button (
), press the Select Destination button up or down until
the destination you want to scan to is listed in the scanner’s LCD.
Download from Www.Somanuals.com. All Manuals Search And Download.
30
Scanning from scanner buttons
Back to TOC
Sending a scan to a website
Scanning for photo reprints
On some models, you can share images with other people by scanning
You can scan photographs and prepare them for photo reprints by
using the Photo Reprint button ( ). Photo reprints optimize the use
directly to the Web with the Share-to-Web button (
). People you
know can view photos and other items by visiting your website, which
will have its own address.
of photo paper, allowing you to print multiple photos on one page. You
can also create pages with multiple photographs for projects such as
photo albums.
At the computer, use the photo printing software provided with your
scanner to arrange photographs, make adjustments, and print
photographs.
1
2
3
4
Close the HP Precisionscan Pro software, the HP Scanjet Copy
Utility, and the HP Scanjet Controls control panel if they are open
on your computer.
Place the original face down on the scanner glass and close the lid.
1
Close the HP Precisionscan Pro software, the HP Scanjet Copy
Utility, and the HP Scanjet Controls control panel if they are open
on your computer.
Press the Share-to-Web button on the front panel of the scanner.
The scanner scans the item using settings optimized for the Web.
Your computer opens the HP Share-to-Web Wizard.
2
3
Place the original face down on the scanner glass and close the lid.
Press the Photo Reprint button on the front panel of the scanner.
The scanner scans the item using settings optimized for
photograph printing. Your computer opens the photo printing
software.
Follow the instructions on the screen to finish posting the scanned
image to your website.
Tip
If your scanner does not have a Share-to-Web
button, scan to the Web using your HP
Precisionscan Pro software. See "Placing a scan on
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from scanner buttons
31
E-mailing a scan
Supported e-mail programs allow the scanner to scan an item as a file
and attach it to a new e-mail message. If a scanned image
automatically appears as a file attachment in a new e-mail message,
your e-mail program is supported.
When you send e-mail using the E-mail button (
), the scanner
scans the item using default settings optimized for mailing. If you have
a supported e-mail program, the scanned image automatically appears
as a file attachment in a new e-mail message, which you then address
and send.
which e-mail program is set as the default.
If your e-mail program is not supported, see Unsupported e-mail
programs on this page.
If you are using an unsupported e-mail program, such as the Web-
based program Microsoft Hotmail®, the scanner cannot scan items
directly into an e-mail message. Instead, the computer can prompt you
to save the item as a file before the scanner completes the scan.
Tip
To view the scanned item before you send it, open
the file attachment from the new e-mail message.
To enable the computer to prompt you to save an item as a file,
complete the following steps:
1
2
3
4
Choose Control Panels from the Apple ( ) menu, and then
choose HP Scanjet Controls from the submenu.
Click the Buttons tab in the HP Scanjet Controls dialog box, and
then click the E-mail tab.
In the Destinations pull-down menu, select a destination. See
"Destinations options" on page 37 for more information.
Select an appropriate type of file for the destination you’ve
selected.
5
6
Close the HP Scanjet Controls dialog box.
Press the E-mail button (
scan.
) and when prompted, save the
After the scan is completed, open an e-mail message and attach the
file as you normally do.
Download from Www.Somanuals.com. All Manuals Search And Download.
32
Scanning from scanner buttons
Back to TOC
1
2
3
Close the HP Precisionscan Pro software, the HP Scanjet Copy
Utility, and the HP Scanjet Controls control panel if they are open
on your computer.
The computer will prompt you each time for a file name. If you do not
want to be prompted, and you want the scanning software to assign an
attachment name automatically, see "Configuring scanner buttons" on
Place the original face down on the scanner glass and close the lid.
Format displays the file type for the e-mail attachment.
Note:
If you need to send the item as a file type other than the
file type shown, scan and save the item using the HP
Press the E-mail button on the scanner.
Note:
If you do not have a supported e-mail program, the
computer might open the HP Scanjet Controls control
panel. See "Unsupported e-mail programs" on page 31
for more information.
4
5
If the computer prompts you for an attachment file name, type a
If you have a supported e-mail program, the scanned image
automatically appears as a file attachment in a new message.
Address the message and send it as you normally do. If you do not
have a supported e-mail program, open your e-mail program and
attach the saved file.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from scanner buttons
33
Printing copies
1
2
3
4
5
Close the HP Precisionscan Pro software, the HP Scanjet Copy
Utility, and the HP Scanjet Controls control panel if they are open
on your computer.
You can scan an item and send it to a printer to make copies using the
scanner button. At the computer, you can see the progress of the scan
or you can cancel the scan. (If you cancel the scan, the printer might
feed a blank page to the output bin.) Note that when you make copies,
each page is treated as a separate print job, so the printer does not
collate copies.
Place the original face down on the scanner glass and close the lid.
(Some models only, see "Front panel and accessories
comparisons" on page 3.) On the scanner, select color or black and
white copies.
Using the scanner button allows you to scan an item and send it to a
printer using default printer and scanner settings. To change the
default printer or scanner settings, open the HP Scanjet Copy Utility in
the HP Scanning Software folder.
(Some models only, see "Front panel and accessories
comparisons" on page 3.) On the scanner, select the number of
copies. The default setting is one copy.
On some scanner models, you can also change the number of copies
or select color or black and white copies from the scanner front panel.
If your scanner does not have buttons for changing the number of
copies or selecting color or black and white copies, open the HP
Scanjet Copy Utility to make these adjustments. (See "Front panel and
Press the Copy button on the scanner. Unless you press +.
(COMMAND KEY+PERIOD) on the computer to cancel the scan, the
number of copies specified in the scanner LCD will print directly to
the default printer.
For more information, see "Using the HP Scanjet Copy Utility" on
Download from Www.Somanuals.com. All Manuals Search And Download.
34
Scanning from scanner buttons
Back to TOC
Canceling a scan
Using Power Save
On some scanner models, you can use the Cancel button ( ) to
cancel a scan in progress. When you press the Cancel button during a
scan, the lamp returns to its starting position. If you press the Cancel
button during a scan from the ADF, the ADF ejects any pages that are
in the process of scanning.
Use the Power Save button ( ) to conserve energy when you are not
using the scanner. When you press the Power Save button, the
scanner lamp and a small indicator light near the Power Save button
turn off and the scanner lamp returns to its starting position.
To use the scanner again, press any button on the front panel of the
scanner or start a scan from the computer. After a short warm-up
cycle, the scan begins.
For information about which scanners include a Cancel button, see
Tip
You can also cancel a scan by pressing +.
(COMMAND KEY+PERIOD) on the computer.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from scanner buttons
35
Changing settings for buttons
Configuring scanner buttons
You can change the default settings for individual scanner buttons.
These changes are applied to all items you scan using that button until
you change the settings again.
Each scanner button has default settings that optimize the scan for the
destination (such as an e-mail program) that is associated with the
button you press.
For more information about the settings you can change, see "Settings
Tip
To change the settings only for the current item, you
might want to scan using the HP Precisionscan Pro
software instead. See "Scanning from HP
1
2
Do one of the following:
l
On the scanner, press the More Options button ( ). (Some
models only, see "Front panel and accessories comparisons" on
page 3.)
l
Choose Control Panels from the Apple ( ) menu, and then
choose HP Scanjet Controls from the submenu.
On the Buttons tab, click the tab for a scanner button to display the
settings that you can change.
Note:
If you click the Scan To tab with some scanner models,
the computer displays a list of destinations (called
Speed Destinations" on page 36 and go to step 3.
3
Change settings for the button. See "Settings for scanner buttons"
on page 37 for more information.
4
5
Repeat steps 2 and 3 to change settings for other buttons.
To restore the default settings, repeat step 2 for any button and
click Restore Defaults.
6
When finished, click the close box.
Download from Www.Somanuals.com. All Manuals Search And Download.
36
Scanning from scanner buttons
Back to TOC
Changing settings for Speed Destinations (some models
only)
1
2
Do one of the following:
l
l
On the scanner, press the More Options button ( ).
On some scanner models, you can use the Select Destination button
to select a destination (called a Speed Destination) when scanning
directly from the scanner front panel. You can change settings for the
Speed Destinations that appear in this list using the HP Scanjet
Controls control panel.
Choose Control Panels from the Apple ( ) menu, and then
choose HP Scanjet Controls from the submenu.
On the Buttons tab, click the Scan To tab. The computer displays
a list of available scanning destinations and the current settings for
these destinations.
panel and accessories comparisons" on page 3. For more information
about the settings you can change, see "Settings for scanner buttons"
3
4
5
Select a destination from the list, and then click Edit. The Edit
Destination dialog box appears.
Change the settings for the destination. For information about
Note:
You cannot change the Prompt for e-mail attachment
name, Prompt for another page, or Automatic
Cropping settings for the Scan To button with Speed
Destinations.
When finished, click OK. The changes you made appear in the
columns next to the destination.
6
7
Repeat steps 3 and 4 to change settings for another destination.
To return to the default settings for a destination:
a Repeat step 3.
b Click Restore Defaults, and then click OK.
Tip
If the destinations that appear on the scanner do not
match the destinations on the Scan To tab of the
HP Scanjet Controls control panel, click Update
Scanner to send the new destinations to the
scanner.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from scanner buttons
37
Type of file
Settings for scanner buttons
When Image is selected, the scanned image is saved as an image file.
If the scanned image contains text, this text is not editable.
Using the HP Scanjet Controls control panel, you can change the
following types of settings for the buttons on your scanner.
When Text is selected, output is converted to one column in what the
software perceives to be the most logical order. Graphics or pictures
from the scanned item are discarded. Use this option to make more
extensive changes to text.
l
l
l
ADF Page Size options (See "ADF Page Size options" on
page 38.)
When Image and Text is selected, output is converted to a format that
creates editable text. Any graphics or pictures in the scanned item are
preserved.
Depending on the destination selected in the Destination pull-down
menu, some options might not be available.
Prompt for Another Page
Note:
Some scanner models also include Speed Destinations
When this option is selected, a prompt appears on the computer after
you scan the first page of a job. The prompt asks if you have more
pages to scan to this job.
When this option is not selected, you will not be prompted for more
pages. Each scanning job will be treated as a single-page job.
Destinations
When changing settings for Speed Destinations, this option is not
available. To scan multiple pages, use the ADF or the
HP Precisionscan Pro software.
The Destinations pull-down menu lists the available destinations on
your computer. These destinations include the following:
Prompt for e-mail attachment name
l
File types: Options include Image, Text, and Image and Text.
Choose Image when scanning items that you want to be saved
using an image file type, such as JPEG. Choose Text when
scanning items containing only text that you want to edit in a word-
processing program. Choose Image and Text when you are
scanning items containing both images and text you want to edit.
When this option is selected, the scanning software prompts you to
enter a name each time for e-mail attachments.
When this option is not selected, the scanning software assigns an
attachment name automatically.
When changing settings for Speed Destinations, this option is not
available. The names for e-mail attachments are generated
automatically. If you need to specify names for e-mail attachments, use
the E-mail button to scan the item.
l
l
Programs: The HP Precisionscan Pro software recognizes the
programs listed in the pull-down menu.
None: When None is selected and you press the scanner button,
the HP Scanjet Controls control panel opens on your computer,
allowing you to select a destination for the scan.
Download from Www.Somanuals.com. All Manuals Search And Download.
38
Scanning from scanner buttons
Back to TOC
Resolution
If you are using an ADF with the scanner, select the size of the pages
you load in the ADF:
Select a resolution from the pull-down menu, or type a resolution in the
text box.
l
l
l
Letter
Legal
A4
Output Type
From the Output Type pull-down menu, select one of the options
below:
l
l
l
True Color creates an image that is rendered with 24-bits per pixel
per color.
256 Color Palette creates an image that contains the 240 most
common colors in the image, plus the 16 basic colors.
Grayscale creates an image containing shades of gray, not just
black and white. In a grayscale image, each pixel contains multiple
bits of information, allowing more shades of gray to be recorded
and displayed.
l
Black & White creates an image that contains only black pixels
and white pixels, no colors or shades of gray. Each pixel
represents one bit.
For more information about using these options, see "List of file types"
Automatic Cropping
When this option is selected, the scanner includes only the item or
items placed in the top right corner of the scanner glass in the scanned
image.
When this option is not selected, the scanner includes the entire area
of the scanner glass, including blank areas, in the scanned image.
When changing settings for Speed Destinations, this option is not
available. Instead, if the destination you are using scans the item using
the Image option, Automatic Cropping is selected. If the destination
scans the item using the Text or Image and Text option, Automatic
Cropping is not selected.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
39
Scanning from HP Precisionscan Pro
3
Using the HP Precisionscan Pro software, you can preview scanned
images and make changes to the images before you send them to a
destination or file them. You start the HP Precisionscan Pro software
from a scanner button or the HP Scanning Software folder on your
computer.
Overview of the HP Precisionscan Pro
software
The HP Precisionscan Pro software provides preview capabilities and
tools for changing an image. Some of the changes you can make
include:
You can also start the HP Precisionscan Pro software from another
program, such as a word-processing or image-editing program, if the
program is compliant with TWAIN or supports the HP Scanjet Plug-in.
l
select only part of, or crop, the preview image to become the final
scanned image
l
l
l
change the resolution
resize the scanned image
change the contrast
Download from Www.Somanuals.com. All Manuals Search And Download.
40
Scanning from HP Precisionscan Pro
Back to TOC
Starting the HP Precisionscan Pro software
Finding help for using the software
To start the HP Precisionscan Pro software, press the Scan To button
The HP Precisionscan Pro software provides a variety of assistance.
(
), or in the HP Scanning Software folder, double-click
HP Precisionscan Pro. The software starts.
To view the function of a command, place the cursor over the
command until an explanation appears.
Smart Friends are tips that appear automatically to notify you of
potential problems. For example, if you are setting a very high
resolution but want to use e-mail to send the scanned image, a Smart
Friend would alert you that the file will probably be too large to e-mail.
To turn individual messages off, select the Don’t remind me again
check box in the message’s dialog box. To turn all messages off, click
Disable All Smart Friends on the Help menu. To turn all messages
back on, click Enable All Smart Friends.
For more information about the types of assistance the software itself
information about keyboard shortcuts, menu items, toolbars, and
cursor appearance, see "Using software commands and controls" on
The online Help is an easy-to-use source of information about using
the scanner and software, troubleshooting, support, and specifications.
To gain access to the Help: on the Help menu, click
HP Precisionscan Pro 3.1 Help. Or, click the Help button in any
dialog box in which it appears.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
41
2
Start the scan in one of these ways:
Performing a new scan
l
l
In the HP Precisionscan Pro software, click
on the toolbar.
In the HP Precisionscan Pro software, click New Scan on the
Scan menu.
Once you start a new scan, the scanner does a preliminary scan of the
item and displays the scanned image in the HP Precisionscan Pro
software. Then, you can see the scanned image and edit it, if
necessary, before sending it to a destination or saving it as a file.
The scanned image appears in the HP Precisionscan Pro software.
This scanned image is the preview image. You can make changes,
such as selecting only part of the image or adjusting the contrast.
When you send the image to another program such as e-mail, place
the image on a website, or save it as a file, the scanner performs a final
scan of the item that includes any changes you made. Directions for
making optional adjustments and completing the scan appear in this
section.
Use these steps to start a scan from the HP Precisionscan Pro
1
Place the original face down on the scanner glass and close the lid.
Note:
To load items in the HP Scanjet Automatic Document
Feeder (ADF), see "Scanning from the ADF" on
Download from Www.Somanuals.com. All Manuals Search And Download.
42
Scanning from HP Precisionscan Pro
Back to TOC
Cropping or selecting an area for final
scan
Do one of the following:
l
l
Move the cursor over the area you want and click.
When the cursor looks like this: , click on one corner of the area
Once a scanned image appears in the HP Precisionscan Pro software,
you must select which area becomes the final scanned image by
creating a selection area. When you create a selection area, a dotted
selection border appears around the area:
you want and drag the cursor to the opposite corner to draw a
rectangular selection area.
l
On the Edit menu, click Select All. The entire scanner bed,
including blank areas, is selected.
selection
border
Click the edge of the selection border and drag to change the selection
area.
Move the cursor over the selection area. When the cursor looks like
this:
, click and drag the selection border to the new location.
Do one of the following:
l
l
Press ESC.
For information about the appearance of the cursor when it is over an
area of the selection border, see "Context-sensitive cursors" on
On the Edit menu, click Unselect All.
Tip
If you only want to look more closely at an area
without changing what will be included in the final
scan, see "Getting a closer look (zooming)" on
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
43
Getting a closer look (zooming)
Selecting output type
Zoom in on the selection area to look at it more closely or make
changes to it. Zoom out to view the entire preview image, or so you
can select a different area of the image to view. Zooming in on the
selection area before making changes or performing a final scan
provides the best final results. The zoom commands are not available
if you have not created a selection area.
When Automatically Set Type is selected, the scanning software
automatically chooses an output type based on the type of item you
are scanning. However, you can change the output type yourself when
you want. Choose the output type based on how you will use the final
scanned image as well as the type of item you are scanning.
Zooming in and out does not change which part of the image becomes
the final scan, nor does it change the final output size (physical output
dimensions). To change which part of the image becomes the final
scanned image, see "Cropping or selecting an area for final scan" on
1
Do one of the following:
l
If it is not already selected, click Automatically Set Type on the
Output Type menu, to allow the software to choose the best
output type for this type of original item.
l
To change the output type only for this scan, keep
Automatically Set Type selected and select an output type you
After creating a selection area, do one of the following:
l
l
On the View menu, click Zoom in.
Click
l
To change the output type for this scan and all other scans in
this session, clear Automatically Set Type and select an output
.
Do one of the following:
l
On the View menu, click Zoom out to return to the original view of
the image.
Tip
When you redraw the selection border, the output
type might change if Automatically Set Type is
selected in the HP Precisionscan Pro
Preferences dialog box.
l
Click
.
Download from Www.Somanuals.com. All Manuals Search And Download.
44
Scanning from HP Precisionscan Pro
Back to TOC
On the Output Type menu, click Automatically Set Type. The
software chooses the best output type based on the image inside the
selection area.
Use this output
type
For these uses
Color photos or drawings with lots of shading to be:
True Color
l
l
l
printed on a color printer
displayed on a color monitor set to millions of colors
displayed on Web and saved in the JPEG or PNG file
format
Color photos or drawings with shading to be:
Optimized Palette
System Palette
l
l
l
l
printed to a color printer
sent via e-mail
used in any way that requires a small file size
viewed on a computer screen
Color photos or drawings with shading to be:
l
l
l
printed to a color printer
displayed on a monitor set to 256 colors
displayed on Web and saved as a GIF file
Color photos or drawings with shading to be printed to a
B&W printer.
Grayscale
Grayscale
B&W photos and drawings with shading to be used for any
purpose.
B&W drawings without shading to be placed in another
program without resizing in the other program.
Black & White
Bitmap
Any image to be saved in GIF file format and displayed on
the Web.
Web Palette
Spot Color
Color drawings or logos without much shading and with a
concentrated area of a single color. The image is to be used
for any purpose.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
45
Resizing (output dimensions)
Making optional adjustments, basic
You can resize the image before you do the final scan by changing the
output dimensions. Resizing the scanned image to the actual
dimensions you need before performing the final scan helps ensure
the best image quality.
These tools are needed most often, but using any of them is optional.
Depending on the output type chosen, some tools will not be available.
Note:
When a tool is open on the desktop, the HP
Precisionscan Pro software scans the item using the
current settings in the tool. However, these settings
might not be the best settings for the type of item being
scanned. To enable the scanner to scan using the best
settings automatically, close the tool.
Tip
If you need to resize images to fit in a file, such as
word-processing document, resize them here in the
scanning software. Resizing images in the other
program may cause them to be fuzzy or have
jagged edges.
1
2
On the Tools menu, click Resize. The Resize dialog box opens.
Do one of the following:
l
If necessary, select a unit of measure in the Units field. In the
Output Dimensions area, type a new value in the Width or
Height field and press ENTER.
l
In the Scale field, select a scale percentage.
New values appear in the Scale, Width, and Height fields, but the
selection area and the scanned image on screen remain the same.
Resizing occurs when you complete the scan.
3
If you want, click
. This locks the output dimensions you
defined so you can change the selection area without changing the
output dimensions. When you change the selection border, the
software resizes the border proportionally. The output dimensions
remain the same.
Download from Www.Somanuals.com. All Manuals Search And Download.
46
Scanning from HP Precisionscan Pro
Back to TOC
Changing resolution
1
2
Open the Resolution tool, if it is not already open.
Click
Resolution determines the amount of data in a scanned image. The
scanning software chooses the optimal resolution based on the output
type. This resolution generally does not need to change.
.
If you do change the resolution, choose one no higher than the
capabilities of the monitor or printer and one appropriate for the type of
scanned image. For example, to print on a 600 dpi printer, choose 600
for black and white bitmap images, but choose only 200 for color or
grayscale images. These resolutions produce optimal quality while
keeping file sizes small.
Changing contrast
The contrast is controlled by the midtone, highlight, and shadow
Selecting higher resolutions for color images increases file size while
not increasing quality. If you double the resolution, the file size
quadruples. Large file sizes can prevent you from doing certain tasks,
such as e-mailing, or can take up too much space on your computer.
For help choosing a resolution based on the type of original item and
On the Tools menu, click Resolution.
Note:
When the Resolution tool is enabled, a checkmark
appears beside the Resolution command in the Tools
menu, and the Resolution tool appears in the toolbar.
1
2
Open the Resolution tool, if it is not already open.
Do one of the following:
l
l
Select a value from the list.
Type a value between 12 and 999,999 in the field and press
ENTER.
The resolution changes as soon as you select a value.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
47
Rotating an image
Mirroring (reversing) an image
You can rotate the image in 90-degree increments clockwise or
counterclockwise. You might need to rotate the image if you placed the
bottom of the item at the top of the scanner glass, or if the item was
sideways. Items such as negatives in their template often scan
sideways.
You can mirror, or reverse, an image from side to side on the vertical
axis. Mirroring an image allows you to see the elements of the image
on the opposite side of their actual position. Mirroring can be
particularly useful for items such as negatives that might be placed in
their template backward and scanned in reverse.
Do one of the following:
l
To rotate an image clockwise: On the Tools menu, click Rotate
right 90°. Or, click on the toolbar. Repeat to continue turning.
l
To rotate an image counterclockwise: On the Tools menu, click
Rotate left 90°. Or, click
on the toolbar. Repeat to continue
turning.
On the Tools menu, click Mirror. Repeat to return to the original
layout.
Download from Www.Somanuals.com. All Manuals Search And Download.
48
Scanning from HP Precisionscan Pro
Back to TOC
Sharpening an image
Resetting all adjustments
Increasing sharpening enhances detail in the image. The
HP Precisionscan Pro software automatically selects the optimal
sharpen level, but you can change it.
You can reset images to the optimal (default) values the scanning
software chose for the image. Optimal values are based on the output
type selected. Resetting removes all adjustments you have made
except the output type, zoom level, or the selection area.
You might want to increase sharpening if the image looks fuzzy.
Conversely, you might want to decrease sharpening if the original item
has flaws or marks on it. Increasing sharpening, or increasing it too
much, can accent the flaws and create undesirable patterns.
Do one of the following:
l
l
On the Edit menu, click Reset Tools.
On the toolbar, click
.
On the Tools menu, click Sharpen.
Note:
When the Sharpen tool is enabled, a checkmark
appears beside the Sharpen command in the Tools
menu, and the Sharpen tool appears in the toolbar.
1
2
Open the Sharpen tool, if it is not already open.
Select a sharpen level from the list. Check the preview image to
see the effects of the change.
Note:
To see the effects of the new sharpen level more easily,
zoom in on the selection area. See "Getting a closer
1
2
Open the Sharpen tool, if it is not already open.
Click
.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
49
Inverting the image
Making optional adjustments, advanced
Use the Invert command to convert white areas of an image to black
and black to white. For color images, a color is converted to its
complementary color. Generally, this command is useful for drawings
and spot color images.
These optional adjustments are ones that most people generally do
not use or need, but some advanced users might want them for special
effects or other needs. Depending on the output type chosen, some
tools are not available.
Note:
When a tool, such as Invert Colors, is open on the
desktop, the HP Precisionscan Pro software scans the
item using the current settings in the tool, instead of
using automatic adjustment features. To enable the HP
Precisionscan Pro software to use automatic
On the Advanced menu, click Invert Colors. Repeat to reverse the
colors again.
adjustment features, close the tool. For more
Download from Www.Somanuals.com. All Manuals Search And Download.
50
Scanning from HP Precisionscan Pro
Back to TOC
Changing midtones
1
2
On the Advanced menu, click Adjust Exposure.
The midtone setting lets you lighten or darken the middle values in an
image. The range for the number in the Midtone field is 1.0 to 4.0.
Moving toward 1.0 darkens the image. Moving toward 4.0 lightens the
image.
Do one of the following:
l
l
l
Drag the Midtone slider to the right.
Type a higher number in the Midtone field and press ENTER.
Click the Up arrow next to the Midtone field.
To adjust midtones for slides, negatives, or other transparent items,
1
2
On the Advanced menu, click Adjust Exposure.
Midtone set at 1.8
(the default)
Midtone set at 3.0
Do one of the following:
l
l
l
Drag the Midtone slider to the left.
Type a lower number in the Midtone field and press ENTER.
Click the Down arrow next to the Midtone field.
1
2
On the Advanced menu, click Adjust Exposure.
Click Auto to return the midtone, highlight, and shadow to the
default settings for this scanned image. Clicking Auto also returns
output levels to the defaults. See "Setting pixel output levels" on
Tip
If you are sharing the image with others who will be
viewing it on a computer screen, the Midtone value
2.2 is recommended because it is an average value
that works with many different monitors.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
51
Changing highlights
1
2
On the Advanced menu, click Adjust Exposure.
The highlight is the value in the image that is represented on the
screen as white. All values lighter than the highlight also appear as
white.
Do one of the following:
l
l
l
Drag the Highlight slider toward the right.
Type a higher number in the Highlights field and press ENTER.
Click the Up arrow next to the Highlight field.
The image has a default highlight setting. Selecting a higher number
makes more of the lighter values distinct, which increases detail in light
areas. Selecting a lower number makes fewer of the lighter values
distinct, which reduces detail in the light areas.
To adjust highlights for slides, negatives, or other transparent items,
1
2
On the Advanced menu, click Adjust Exposure.
Do one of the following:
l
l
l
Drag the Highlight slider toward the left.
Highlights set at 215
Highlights set at 122
Type a lower number in the Highlights field and press ENTER.
Click the Down arrow next to the Highlight field.
Click
(white eyedropper). When the cursor changes to the
eydropper, move it over the area you want to be the highlight and click.
1
2
On the Advanced menu, click Adjust Exposure.
Click Auto to return the midtone, highlight, and shadow to the
default settings for this scanned image. Clicking Auto also returns
output levels to the defaults. See "Setting pixel output levels" on
Download from Www.Somanuals.com. All Manuals Search And Download.
52
Scanning from HP Precisionscan Pro
Back to TOC
Changing shadows
1
2
On the Advanced menu, click Adjust Exposure.
The shadow is the value in the image that is represented on the screen
as black. All values darker than the shadow also appear as black.
Do one of the following:
l
l
l
Drag the Shadows slider toward the right.
The image has a default shadows value. Selecting a higher number
makes more of the darker values distinct, which increases detail in
dark areas. Selecting a lower number makes fewer of the darker
values distinct, which reduces detail in the dark areas.
Type a higher number in the Shadows field and press ENTER.
Click the Up arrow next to the Shadows field.
To adjust shadows for slides, negatives, or other transparent items,
1
2
On the Advanced menu, click Adjust Exposure.
Do one of the following:
l
l
l
Drag the Shadows slider toward the left.
Shadow set at 10
Shadow set at 3
Type a lower number in the Shadows field and press ENTER.
Click the Down arrow next to the Shadows field.
Click
(black eyedropper). When the cursor changes to the
eydropper, move it over the area you want to be the shadow and click.
1
2
On the Advanced menu, click Adjust Exposure.
Click Auto to return the midtone, highlight, and shadow to the
default settings for this scanned image. Clicking Auto also returns
output levels to the defaults. See "Setting pixel output levels" on
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
53
Checking for clipped areas
1
2
On the Advanced menu, click Adjust Exposure.
The lightest or darkest areas of an image that will print without any
detail in them are known as clipped areas. The lightest areas, or
highlights, will print as the color of the paper (without ink or toner) and
therefore will have no detail. The darkest areas, or shadows, will print
saturated in the blackest color of ink or toner, and therefore will also
have no detail.
Click
(Highlight Alarm). The light areas in the image that will
print as white (no detail) appear black.
3
4
In the Highlights setting, click the Up arrow repeatedly until the
clipped pixels disappear from the image. The result of the change
can be seen.
You can view and change clipped areas if you want those areas to
contain detail when they print.
Click
again to turn the Highlight Alarm off.
1
2
On the Advanced menu, click Adjust Exposure.
Click (Shadow Alarm). The darker areas in the image that will
print as black (without detail) appear white.
3
4
In the Shadow setting, click the Down arrow repeatedly until the
clipped pixels disappear from the image. The result of the change
can be seen.
Click
again to turn the Shadow Alarm off.
Normal view
View when
Highlight
Alarm
View when
Shadow
Alarm
selected
selected
Download from Www.Somanuals.com. All Manuals Search And Download.
54
Scanning from HP Precisionscan Pro
Back to TOC
Setting pixel output levels
1
2
On the Advanced menu, click Adjust Exposure.
The output levels setting lets you create interesting effects for scanned
pictures. When you select this command, the Black and White output
levels appear. By default, white is set to 255, and black is set to 0.
Click the triangle at the bottom of the dialog box to display the
current White and Black output levels.
3
To change the levels, do one of the following:
Decreasing the White output level makes the overall image darker.
Increasing the Black output level makes the image more faded.
Changing the White output level value to 0 and the Black output level
value to 255 inverts the colors in the image.
l
l
Click one side of a slider.
Type a different number in the White or Black field and press
ENTER.
To change the ranges for the numbers in the White and Black fields,
l
Click the Up or Down arrow next to the White field or Black
field.
The result of the changes to output levels can be seen in the preview
area.
Tip
To use an image as a light background for dark text,
such as for an overhead transparency, increase the
Black output level until the image is as faint as you
want.
1
2
On the Advanced menu, click Adjust Exposure.
Click Auto to return the midtone, highlight, shadow, and output
levels to the default settings for this scanned image.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
55
Viewing RGB values and pixels
About the histogram
You can view the RGB values and pixel color for any spot in a color or
grayscale image using the RGB meter.
The histogram is a graph of the distribution of pixels in the selection
area. The magenta line represents the current setting for shadow. The
red line represents the current setting for highlight. The midtone setting
is not represented.
To view the RGB values and pixel color for slides, negatives, or other
transparent items, use "Viewing RGB values and pixel color" on
Highlight
Shadow
1
2
On the Advanced menu, click Adjust Exposure.
Move the pointer over the image. The RGB values and pixel color
appear in the RGB meter.
The turquoise line appears in the histogram when either eyedropper
cursor is positioned over the image. This line shows you where in the
histogram the pixels in that area of the image occur.
RGB
values
Pixel
color
Where pixels in the
image under the
eyedropper fall
Note:
Do not click while the eyedropper pointer is over the
image unless you want to change the setting for
highlight or shadow.
3
Click the same eyedropper button again. The RGB meter dims and
the cursor returns to normal.
The histogram represents pixel distribution in the preview image, not in
the final scanned image. Changing the selection area changes the
histogram. Changing the setting for highlight or shadow does not
change the histogram.
Download from Www.Somanuals.com. All Manuals Search And Download.
56
Scanning from HP Precisionscan Pro
Back to TOC
Changing the hue
Changing the saturation
Color in an image consists of its hue and the saturation. Hue refers to
the overall color cast of the image.
Color in an image consists of its hue and the saturation. Saturation
refers to the intensity of the colors.
The software sets the hue for an image, but you can change it. You
might want to change it if the image has too much of one color, or if you
want to create a special effect.
The software sets the saturation for an image, but you can change it.
You might want to change it to make colors in the image more or less
vivid, or to create a special effect. The range in the Saturation field is
0 to 150.
1
On the Advanced menu, click Adjust Color.
1
2
On the Advanced menu, click Adjust Color.
Change the overall color of the image by
doing one of the following on the color
wheel.
Indicator circle
Arrows
Make colors more vivid by doing one of the following:
l
l
l
Click to the right of the slider.
l
Drag the indicator circle to a new
area.
Type a higher number in the Saturation field and press ENTER.
Click the Up arrow next to the Saturation field.
l
Click the arrow for a color on the
outer edge of the wheel.
The result of the change can be seen in
the image.
1
2
On the Advanced menu, click Adjust Color.
Make colors less vivid by doing one of the following:
l
l
l
Click to the left of the slider.
Type a lower number in the Saturation field and press ENTER.
Click the Down arrow next to the Saturation field.
Tip
If the image has too much of one color, move the
indicator circle away from that color.
1
2
On the Advanced menu, click Adjust Color.
1
2
On the Advanced menu, click Adjust Color.
Click Auto to return to the default hue and saturation settings for
this scanned image.
Click Auto to return to the default hue and saturation settings for
this scanned image.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
57
Changing the black and white threshold
1
Make sure that Black & White Bitmap is selected on the Output
Type menu. The selection should have a dot beside it.
Changing the black and white threshold only applies to images using
the Black & White Bitmap output type. The threshold is a value in the
image that represents the border between black and white. All values
in the image that are lighter than the threshold appear as white, and all
values darker appear as black.
2
3
On the Advanced menu, click Adjust Black & White.
Do one of the following:
l
l
l
Drag the slider.
The image has a default threshold value. Choosing a number closer to
zero makes more values appear as white. Choosing a higher number
makes more values appear as black.
Type a new value in the field and press ENTER.
Click the Up or Down arrow next to the field.
1
2
On the Advanced menu, click Adjust Black & White.
Click Auto.
Threshold at 127
(the default for this image)
Threshold at 45
Download from Www.Somanuals.com. All Manuals Search And Download.
58
Scanning from HP Precisionscan Pro
Back to TOC
Setting which colors become black or white in black &
white bitmaps
1
Make sure that Black & White Bitmap is selected on the Output
Type menu. The selection should have a dot beside it.
This procedure only applies to color images that will be using the Black
& White Bitmap output type. It allows you to create special effects, or to
correct for originals on colored paper.
2
3
On the Advanced menu, click Adjust Black & White.
Select a color channel from the Scan using channel list.
l
l
Choose Red to change the red in the image to white. Green and
blue become black. Useful for originals printed on pink or red
paper.
Images consist of pixels. In color images, each pixel has a varying
amount of Red, Green, or Blue to create its specific color. You can
determine whether the Red, Green, or Blue in each pixel turns to black
or white in the final scanned image.
Choose Green to change the green in the image to white. Red
and blue become black. Useful for originals printed on green
paper.
l
l
Choose Blue to change the blue in the image to white. Red and
green become black.Useful for originals printed on blue paper.
Choose NTSC Gray to convert light shades of all colors to white
and dark shades of all colors to black. (No one color becomes all
white or all black.) Colors are converted to gray at a ratio of 30%
red, 59% green, and 11% blue.
1
Make sure that Black & White Bitmap is selected on the Output
Type menu. The selection should have a checkmark beside it.
2
3
4
On the Advanced menu, click Adjust Black & White.
Choose NTSC Gray from the Scan using channel list.
Click Auto.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
59
Descreening images
Resetting all adjustments
Use the Descreen command to reduce undesirable patterns in printed
items you are scanning. An example of an undesirable pattern is a
moiré pattern, or the circles that often appear on pictures printed in
newspapers.
You can reset images to the optimal (default) values the scanning
software chose for the image. Optimal values are based on the output
type selected. Resetting removes all adjustments you have made
except the output type, zoom level, or the selection area.
Note that scanning takes longer when this command is selected. Use
Descreen only when you see undesirable patterns on the scan of a
printed original. When Descreen is turned on or off, a new preview
scan starts and image adjustments are reset.
Do one of the following:
l
l
On the Edit menu, click Reset Tools.
On the toolbar, click
.
On the Advanced menu, click Descreen. Select the option again to
turn it off.
Download from Www.Somanuals.com. All Manuals Search And Download.
60
Scanning from HP Precisionscan Pro
Back to TOC
Sending to a program
Completing the final scan
Once you finish viewing and changing the scanned image, you can
perform a final scan and send it directly to a program such as e-mail. If
the program you want is not available, save the image as a file and
insert it into the destination program as you normally would.
When you finish making changes, you need to complete the final scan
by doing one of these tasks:
l
l
Sending to a program. See this page.
Tip
If you send text to Word or another word-processing
program and the text appears inside a frame you do
not want, double-click the frame border and click
Remove Frame or a similar command. To prevent
this from happening in the future, see "Setting
l
l
l
l
l
l
l
l
1
2
3
On the Scan menu, click Scan To.
Choose a program from the list and click Scan.
When you do any of these procedures, the scanner performs a final
scan including your changes before sending it to the program or printer
you choose, copying the image, or completing any other function.
If the program you select accepts multipage files, you might be
asked if you have more pages to scan to this file. Do one of the
following:
Images are not automatically saved as files if you print them, send
them to a another program, or copy and paste them into a file in
another program. To use the scanned image again, be sure to save it.
l
l
If this is a one-page item, click Done.
If there are more pages of this item, load the next page in the
scanner and click Scan on the computer. Repeat until all pages
are scanned. Then, click Done.
The destination program opens and displays the scanned image.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
61
Returning the image to a program that supports
TWAIN or the HP Scanjet Plug-in
Saving to a file
Save scanned images as files when you want to use the images again
later. For help deciding on which file type to use, see "List of file types"
If you started the scan from a program that supports TWAIN or the
HP Scanjet Plug-in, you can perform a final scan and return the image
to that program using this procedure. For more information about
scanning using TWAIN or the HP Scanjet Plug-in, see "Scanning from
1
Do one of the following:
l
l
On the Scan menu, click Save As.
On the toolbar, click
Do one of the following:
.
l
l
On the Scan menu, click Return Image To.
On the toolbar, click
2
3
4
.
Select a name and location for the file and click OK.
If the Options button is available, more options are available for
this file type. Click Options, change any options you want, and
click OK.
The file type you need depends on how you will use the file. And, some
file types are not available when certain output types are selected.
If you plan to process a scanned document with your optical character
recognition (OCR) software, use the following settings:
l
l
l
Resolution: 300
Output type: Black & White Bitmap
Format: TIFF
Note:
Selecting higher resolutions than 300 dpi will not
increase OCR accuracy.
Download from Www.Somanuals.com. All Manuals Search And Download.
62
Scanning from HP Precisionscan Pro
Back to TOC
l
l
by programs that work with photographs and other images. A TIFF
file is a bitmapped graphic (also called a raster graphic) and can be
any resolution. TIFF image files can be used on multiple platforms.
Image file formats
l
be used on the Web or on multiple platforms. Cannot be used with
True Color output type.
TIFF compressed. TIFF compressed files for images are smaller
than standard TIFF files.
l
are small file sizes and speed. The trade-off for these advantages,
though, is reduced image quality. Because each time an image is
compressed with JPEG it loses a little of the image data, avoid
compressing a file with JPEG more than once. JPEG is an
appropriate file format for an image that will be used on the Web or
on multiple platforms.
Text or text-and-image file formats
l
HTML. HTML is useful for text and graphics that will be viewed on
the World Wide Web. When this format is selected for a scanned
image containing both text and images, the text is converted to
editable text and is saved as HTML, and the graphics are saved as
GIF or JPEG files.
You can save your JPEG file as a progressive JPEG. When used
on a Web page, a progressive JPEG is initially sent as just every
other line, with the remaining lines sent immediately after. This
allows a (somewhat blurry) image to display sooner. Most people
prefer this. JPEG can be used only with True Color and Grayscale
output types.
l
l
text or text and pictures. The formatting of text in an RTF file can
usually be retained and then interpreted by other programs.
area. Text will be editable, unformatted, ASCII text.
l
l
l
GIF, PNG uses non-lossy compression, which means all the visual
data is saved and restored when the file is decompressed. Unlike
GIF, PNG can be used with True Color and Grayscale output types.
Macintosh operating system. Designed for the screen, this format
is best used for color images that will not be printed. Images saved
as PICT files are smaller in size than images saved as a TIFF files.
Adobe Acrobat Reader to view PDF files. If no changes need to be
made to the file, this file type is useful for sharing (as through
e-mail) and filing because of its generally small file size. When
using the Macintosh version of the scanning software, you can only
create image-only PDF files; you cannot copy text from these files.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
63
Printing
The selection area is the part of the image that prints. If there is no
selection border, the contents of the entire scanner bed, including
blank areas, print.
Printing does not save the image to the computer. Save the scanned
image to a file to use the image later.
1
2
Do one of the following:
l
l
On the Scan menu, click Print.
On the toolbar, click
.
In the Print dialog box, select the options you want and click OK.
Download from Www.Somanuals.com. All Manuals Search And Download.
64
Scanning from HP Precisionscan Pro
Back to TOC
Placing a scan on a website
Preparing a scan for online viewing
You can share images with other people by scanning directly to the
Web. People you know can view photos and other items by visiting
your website, which will have its own address.
There are many website development applications, or HTML editors,
available. These applications help you develop websites, and they
support a variety of graphic file formats. However, not all Web
browsers can display all the file formats that website development
applications support.
With the HP scanning software, you can scan your text or images,
make adjustments to these scans, and then prepare them for the
World Wide Web.
Tip
If you want to place a scan on a site other than an
HP Share-to-Web website, save the scanned image
as a file and then place the file on the site as you
normally do. See "Preparing a scan for online
To optimize a scan for a website, be sure to do the following:
l
Save scans as GIF, JPEG, or PNG files. (Most Web browsers use
these file formats.)
1
Do one of the following:
l
l
For color images, choose the Web Palette output type.
l
l
On the Scan menu, click Scan To.
Select a resolution of 72 dpi. (This resolution produces smaller file
sizes than higher resolutions, and the images still look good on the
computer screen.)
On the toolbar, click
.
2
3
Select HP Share-to-Web from the list and click Scan.
Follow the instructions on the screen to finish posting the scanned
image to the website.
l
Scale or resize your scanned image in the scanning software
before inserting the image into your document.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
65
Copying and pasting into another program
To scan an item for placement on a website, use one of the following
methods:
You can copy the scanned image to the Clipboard and then paste it
into a file in the destination program. After the image is pasted, it
becomes a part of the file.
l
Drag-and-drop from the scanning software
If your website development application supports drag-and-drop,
you can drag the image from the Preview area of the scanning
software and drop it into the open Web page where you want it.
Some website development applications have image editing
capabilities if you want to adjust the image further. See the
documentation that came with the website development application
for more information.
1
In the HP Precisionscan Pro software, do one of the following:
l
l
On the Edit menu, click Copy.
On the toolbar, click
.
2
3
In the destination program, place the cursor where you want to
insert the scanned image and click.
l
l
Save the image as a file
You can save the image as a file in the scanning software, and then
insert that file into your website development application.
Remember to save the file as a GIF, JPEG, or PNG file.
Choose the Paste command in the program.
Copy and paste the image
You can use the scanning software's Copy command or icon to
copy the image to the Clipboard. In the website development
application, use the Paste command to paste the image into the
open Web page.
l
Use the Scan To command
You can use the scanning software's Scan To command in the
Scan menu to scan the image to a text file. Then, in the Save
dialog box, select HTML in the Format pull-down menu.
Download from Www.Somanuals.com. All Manuals Search And Download.
66
Scanning from HP Precisionscan Pro
Back to TOC
Dragging-and-dropping into another program
Dragging-and-dropping to the desktop or a folder
You can drag-and-drop a scanned image into another program if that
program supports drag-and-drop. If the program does not support
drag-and-drop, the selection area returns to the scanning software
window.
Scanned images you drag-and-drop to the desktop or a folder become
a Scrapbook picture clipping file. The bitmap file is given a generic
name such as “picture clipping.” Subsequent images scanned to the
desktop or that folder are numbered sequentially.
1
2
3
Open a file in the destination program. Make sure you can see both
the destination program and the HP Precisionscan Pro software.
1
2
3
Make sure you can see both the HP Precisionscan Pro software
and the desktop or the folder you want.
In the HP Precisionscan Pro software, place the cursor over the
scanned image.
In the HP Precisionscan Pro software, place the cursor over the
scanned image.
While pressing OPTION, click inside the selection area and drag to
the location in the destination program. Then, release the mouse
button and OPTION. Wait for the scanner to perform a final scan of
the image.
While pressing OPTION, click inside the selection area and drag to
the desktop or folder. Then, release the mouse button and OPTION.
Wait for the scanner to perform a final scan of the image.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
67
Scanning to CD
The Scan to CD function is a quick, convenient way to scan and save
scanned items to a rewritable CD. This feature is a helpful shortcut for
people who frequently archive or store scans on CDs. To scan to a CD,
you must have CD-writer hardware installed and have a rewritable CD
available.
1
2
Start a new scan, and make any adjustments you want in using the
scanning software.
In the HP Precisionscan Pro software, do one of the following:
l
l
On the Scan menu, click Scan to CD.
On the toolbar, click (Scan to CD).
A Save As dialog box appears.
3
If a CD-writer drive is installed, this drive is automatically listed at
the top of the dialog box. If you have created folders on your CD to
organize images, select the desired folder in which to save the
scan.
4
5
Type in a file name.
In the Format pull-down menu, select the file type. To change the
file type, select a different file type in the drop-down list.
6
Click Save.
Download from Www.Somanuals.com. All Manuals Search And Download.
68
Scanning from HP Precisionscan Pro
Back to TOC
Other features and tips
In this section, you can find information about:
l
l
Which settings to use to get the best image quality. (See "Tips for
How to save a group of settings you use all the time and use them
with future scans when you select them. (See "Saving settings" on
page 69.)
l
l
How to change the default settings the scanner uses to scan all
How to start scanning from programs compliant with TWAIN or the
HP Scanjet Plug-in. (See "Scanning from other programs" on
page 74.)
l
How to make scanned text editable. (See "Making scanned text
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
69
Tips for best image quality
Saving settings
Output type, resolution, file type, and values for other controls
determine image quality and file size.
You can save and name a group of settings that you frequently use for
a particular purpose and apply them to items you scan in the future.
For example, if you routinely e-mail pictures to someone, you can save
the settings including the output type, resolution, and dimensions that
you always use. The settings are automatically applied when you scan
a picture and choose the group of settings.
When you first scan an item, the scanner chooses the defaults for
output type and resolution, and you do not need to change them. If you
want to change these settings or want help choosing a file type, see:
l
l
l
Saved settings override the default settings and any changes you
made up to that point. Any changes you make after that point are
preserved.
1
Make sure the scanned image whose settings you want to save is
in the preview window and that you have adjusted any settings for
the image.
Tip
For any image that will be printed, choose TIFF
compressed as the file type to reduce the file size
while maintaining quality. Also, many different
programs recognize this file type.
2
3
On the Scan menu, point to Settings, and click Save. The settings
for the current scanned image appear.
In the drop-down list at the bottom, type a name for these settings
and click Save.
1
2
3
Scan an item to the HP Precisionscan Pro software.
On the Scan menu, point to Settings, and click Load.
Select the group of settings you want from the list at the bottom
and click Load.
Download from Www.Somanuals.com. All Manuals Search And Download.
70
Scanning from HP Precisionscan Pro
Back to TOC
Setting preferences
The preferences are the default settings for all scans performed. To
change a setting only for the item currently being scanned see "Making
1
2
3
On the Scan menu, click Preferences.
Click the tab you want.
Change any settings you want. See the next sections for
descriptions of options on tabs.
4
When finished, click OK.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
71
sRGB Profile (Gamma 2.2)
When selected, the software uses the RGB profile from the screen to
create the color in the final scan. This profile is also known as
Gamma 2.2.
The Scanner tab of the Preferences dialog box controls these
options.
Preview scan when the Scan To button is pushed
Note:
Because Macintosh computers ship with Gamma 1.8,
this option is not selected by default. When using this
option, be sure to select sRGB in your monitor settings.
When selected, a preview of the scan appears when you press the
HP Scanning Software button on the scanner. When cleared, the
software starts, but the scanner does not display a preview scan. Start
a scan from the HP Precisionscan Pro software.
Enable Scan Another Page Dialog
Best Quality Scaling
When selected, a dialog box appears during final scanning that asks
you if there are more pages of this item to scan. When cleared, the
scanner assumes each job is only one page. Applies only to PDF, text,
and RTF formats.
When selected, the highest quality scaling is applied to the final scan.
When cleared, normal quality scaling is applied, making scanning
faster.
Best Quality Sharpening
When selected, the highest quality sharpening is applied to the final
scan. When cleared, normal quality sharpening is applied, making
scanning faster.
Maximum Pixel Depth
When selected, the largest pixel bit depth is acquired from the scanner
to produce the highest quality image. When cleared, less image data is
processed, making scanning faster.
Noise Reduction
When selected, reduces the noise in the image caused by the scanner.
When cleared, noise reduction is not applied, making scanning faster.
Descreening
When selected, a screened background image (such as a watermark)
will be removed from the final scan. When cleared, any background
image (such as a watermark) will be scanned as part of the image in
the final scan.
Download from Www.Somanuals.com. All Manuals Search And Download.
72
Scanning from HP Precisionscan Pro
Back to TOC
The Selection Area tab controls the following preferences.
The Resolution tab controls the default resolution values available
when you select Resolution on the Tools menu.
Automatically create selection area after a mouse click
Default values are already set, but you can add custom resolution
values or delete values. The range of resolution is 12 to 999,999. Click
Add to add a value. Or, select a value and click Delete to delete that
value.
When selected, a selection area will be created around an area on
which you click with the cursor.
Automatically set the Output Type after selection
When selected, the software automatically determines the output type
of the area inside the selection border.
Automatically adjust exposure after selection
When selected, the scanning software automatically changes the
values in the Adjust Exposure or Adjust Black & White dialog boxes
to the optimal values each time you create a new selection area.
Values for an image do not change if you adjust the selection area
while the Adjust Exposure or Adjust B&W Threshold dialog box is
open.
When cleared, the scanning software does not automatically reset the
controls in these two tools.
Automatically adjust color after selection
When selected, the scanning software automatically changes the
values in the Adjust Color dialog box to the optimal values each time
you create a new selection area. Values never change if you create a
different selection area while the Adjust Color dialog box is open.
When cleared, the scanning software does not automatically reset the
controls.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
73
The Text tab of the Preferences dialog box controls the following
The Controls tab of the Preferences dialog box controls the control
preferences related to text output from the OCR program.
range readout to use for scanning.
Text Output (format)
The control range sets the amount of tonal resolution per color
available for correction in the Adjust Exposure command and Adjust
Black & White command. Using a larger number of bits for the control
range results in greater control of compensation for exposure or
threshold correction.
l
Framed text places the text from the page into frames and
attempts to recreate the page formatting as closely as possible to
the original. The program into which the text is placed must support
this type of option.
Choose one of these options:
l
Flowed text eliminates columns and inserts any images in the text
as closely as possible to where they were in the original. Flowed
text is easier to edit.
l
l
l
l
8-bit readout (0-255) — sets the controls to use 8 bits of tonal
resolution per color
10-bit readout (0-1023) — sets the controls to use 10 bits of tonal
resolution per color
Current OCR Language
Allows you to choose the language the OCR program uses to check
words it is processing in the item.
12-bit readout (0-4095) — sets the controls to use 12 bits of tonal
resolution per color
Image Output
16-bit readout (0-65535) — sets the controls to use 16 bits of tonal
Allows you to choose the output type the software uses for scanning
images that appear on pages that include both images and text. This
option is only available if you’ve selected Image and Text in the Edit
Text tab on the Buttons tab of the HP Scanjet Controls dialog box.
resolution per color
l
True Color. Scans images that appear on the page using the True
Color output type. This option creates high-quality images.
However, this option can increase the scanning time and can
create final scans with large file sizes.
l
Optimized Palette. Scans images that appear on the page using
the Optimized Palette output type. This option decreases the time it
takes the scanner to complete the scan and creates final scans
with smaller file sizes. However, the quality of scanned images is
lower.
types available in the scanning software.
Download from Www.Somanuals.com. All Manuals Search And Download.
74
Scanning from HP Precisionscan Pro
Back to TOC
Scanning from other programs
1
2
Start a scan from within the other program by choosing the
Acquire (or similar) command.
You can bring an image directly into an open file in one of your
programs if the program supports TWAIN or the HP Scanjet Plug-in.
Generally, the program is compliant if it has a command such as
Acquire, Scan, or Import New Object. If you are unsure if the
program is compliant or what the command is called, see the
documentation for the program.
If the HP Precisionscan Pro software opens and displays the
preview image, create a selection area. You can crop the scan (if
necessary), select the output type, and make optional adjustments
as you normally would. See the appropriate sections in this chapter
for instructions.
When scanning from within a program that supports TWAIN or the
HP Scanjet Plug-in, the HP Precisionscan Pro software may start if the
program allows it. If the HP Precisionscan Pro software starts, you can
make changes to the image as you normally would. If not, the image
returns to the program immediately.
3
When finished making changes to the scanned image, do one of
the following to perform a final scan and place it in the program
from which you started scanning:
l
l
On the Scan menu, click Return Image To.
Click
.
The image appears in the open program. You might have to reposition
the image.
Tip
If your program does not support TWAIN or the
HP Scanjet Plug-in, you can try to copy and paste or
drag-and-drop the image into the program. Or, save
the image as a file and then place the file in the
program.
If the image does not appear, the program might not accept the
resolution or output type you selected. Rescan the image using the
default settings the software sets for the image.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Scanning from HP Precisionscan Pro
75
Making scanned text editable
1
2
Choose Scan To from the Scan menu.
You can make text on a scanned image editable. The optical character
recognition (OCR) program converts the text to be editable and then
places it in a supported word-processing program. Depending on the
capabilities of the word-processing program, graphics on a scanned
image might be retained or discarded, or the OCR program might try to
convert them and they will appear as random characters.
Choose Text File from the Destination pull-down menu, and then
click Scan.
3
4
Select a text or text-and-image file format in the Format pull-down
If the program you select accepts multipage files, you might be
asked if you have more pages to scan to this file. Do one of the
following:
l
l
If this is a one-page item, click Done.
Tip
If a block of text appears in Microsoft Word or
another word-processing program inside a frame
you do not want, double-click the frame border and
click Remove Frame or a similar command.
If there are more pages of this item, load the next page in the
scanner and click Scan on the computer. Repeat until all pages
are scanned. Then, click Done.
The OCR program opens and creates editable text from the scanned
image.
Note:
You can also save a scanned image and import the
Download from Www.Somanuals.com. All Manuals Search And Download.
76
Scanning from HP Precisionscan Pro
Back to TOC
OCR programs convert some text more accurately than other text.
Because OCR technology is never perfect, proofread all converted text
carefully to ensure the characters have been correctly interpreted.
These types of text convert most accurately:
l
l
l
l
text in standard fonts
text in 9-point font or larger
crisp, clear text
black text on a white background
These types of text might convert less accurately:
l
l
l
text close to non-text elements, such as bullets, lines, or graphics
text in spreadsheets, tables, or forms
letters that have gaps, that “bleed” along their edges, or that touch
other letters
l
l
underlined text
text on colored paper
Handwriting cannot be converted.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
77
Using accessories
4
Some scanners support using the HP Scanjet Automatic Document
Feeder (ADF) and the HP Scanjet Transparency Adapter (XPA) for
scanning slides and negatives. (Some models only, see the "Front
Download from Www.Somanuals.com. All Manuals Search And Download.
78
Using accessories
Back to TOC
2
Adjust the paper guides to center the stack.
Scanning from the ADF
You can scan multiple-page items quickly and easily using the ADF.
When you use the ADF, you can scan to the HP Precisionscan Pro
software or other destinations. For instructions about setting up the
ADF, see the Setup and Support Guide. For information about
1
Place a stack of similarly sized originals in the document input tray,
face up with the first page on top.
3
Do one of the following:
l
Start the HP Precisionscan Pro software and follow the
directions on the computer screen.
l
Press a button on the front of the scanner.
If you start the scan from the HP Precisionscan Pro software or
scan to the HP Precisionscan Pro software using the Scan To
button (
):
a The ADF Scan dialog box opens and displays the current
output type, resolution, and page size, which you can change.
Or, you can click Load Settings and choose settings you have
preset.
b To scan the item to a file, click Scan. Or, to scan directly to a
destination, click Scan To, select a destination, and click Scan.
If you start the scan from any scanner button except the Scan To
button, follow the directions on the screen to complete the scan.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Using accessories
79
Scanning slides
Scanning from the XPA
To scan standard 35 mm slides, use the XPA light source and the
You can scan slides or negatives using the XPA.
positioning plate. When scanning fewer than three slides, you also
need the slide light shield.
Tip
Do not use the XPA to scan a letter-size item, such
as a presentation transparency. Place the
transparent item on the scanner glass, place a white
piece of paper on top, and scan as you normally
would using the Scanner Glass command on the
Scan menu.
1
2
With the XPA light source connected to its port on the scanner,
restart the software.
Place the positioning plate on the scanner glass so the arrow is in
the upper right-hand corner. Push the positioning plate toward the
top right corner.
See the Setup and Support Guide for information about installing the
XPA.
items for the XPA.
3
Slide up to three slides into the slide holder on the bottom side of
the XPA light source. The correct view of the picture should be
facing outward, toward you.
Download from Www.Somanuals.com. All Manuals Search And Download.
80
Using accessories
Back to TOC
6
7
8
From the HP Precisionscan Pro software, click the Scan menu,
and select XPA (Slides).
Before making any changes, see "Making optional adjustments for
When you have finished using the XPA light source, on the Scan
menu, click Scanner Glass. Disconnect the XPA light source if you
want.
Tip
The XPA light source also functions as a light table
for viewing 35 mm slides. Insert slides as shown
above.
To keep the XPA light source on beyond the default
period, select the Faster Scan setting in the HP
Scanjet Controls control panel. See "Setting
4
5
If you are scanning fewer than three slides, insert the slide light
shield after you load your last slide.
Place the XPA light source into the positioning plate with slides
facing down and the HP logo facing you.
HP logo here
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Using accessories
81
3
Slide the strip of negatives into the negative holder. If the negative
strip curves, the curve should be facing out toward you.
Scanning negatives
To scan 35 mm negatives, use the XPA light source, the positioning
plate, and the negative holder. When scanning fewer than four
negative frames, you also need the negative light shield.
CAUTION
Negatives are easily damaged. Touch them only on
the edges.
1
2
With the XPA light source connected to its port on the scanner,
restart the software.
Place the positioning plate on the scanner glass so the arrow is in
the upper right-hand corner. Push the positioning plate toward the
top right corner.
4
If you are scanning a strip of negatives with fewer than four frames,
insert the negative light shield after the negative strip. See the icon
on the negative holder for assistance.
Download from Www.Somanuals.com. All Manuals Search And Download.
82
Using accessories
Back to TOC
5
Slide the negative holder into the slide holder on the bottom side of
the XPA light source.
7
8
9
From the HP Precisionscan Pro software, click the Scan menu,
and select XPA (Negatives).
Before making changes, see "Making optional adjustments for
When finished using the XPA light source, on the Scan menu, click
Scanner Glass. Disconnect the XPA light source if you want.
6
Place the XPA light source into the positioning plate with negatives
facing down and the HP logo facing you.
HP logo here
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Using accessories
83
Adjusting midtones for slides or negatives
Making optional adjustments for slides or
negatives
You can adjust the overall lightness or darkness of the scanned image
using the midtone setting. The range for the number in the Midtone
field is -100 to 100.
You can make optional adjustments to slides or negatives scanned
using the XPA. Before deciding to make adjustments, create a
selection area around one slide or negative so the software
1
2
On the Advanced menu, click Adjust Exposure.
Do one of the following:
If you choose to make adjustments to the image after you create a
selection area, make most of them as you normally would, except for
the following adjustments:
l
l
Drag the Midtone slider up.
Type a higher number in the Midtone field and press ENTER.
l
l
l
l
Midtone. See "Adjusting midtones for slides or negatives" on
Highlight. See "Adjusting highlights for slides or negatives" on
1
2
On the Advanced menu, click Adjust Exposure.
Do one of the following:
Shadow. See "Adjusting shadows for slides or negatives" on
l
l
Drag the Midtone slider down.
Type a lower number in the Midtone field and press ENTER.
RGB values and pixel color. See "Viewing RGB values and pixel
1
2
On the Advanced menu, click Adjust Exposure.
Click Auto to return the midtone, highlight, and shadow settings to
the defaults for this slide or negative.
Tip
advanced" on page 49 to make all adjustments
except the ones mentioned above.
Tip
Download from Www.Somanuals.com. All Manuals Search And Download.
84
Using accessories
Back to TOC
Adjusting highlights for slides or negatives
Adjusting shadows for slides or negatives
You can adjust highlights to lighten or darken the light areas. The
You can adjust shadows to lighten or darken the dark areas. The range
range for the number in the Highlights field is -100 to 100.
for the number in the Shadows field is -100 to 100.
1
2
On the Advanced menu, click Adjust Exposure.
1
2
On the Advanced menu, click Adjust Exposure.
Do one of the following:
Do one of the following:
l
l
Drag the Highlight slider up.
l
l
Drag the Shadow slider up.
Type a higher number in the Highlights field and press ENTER.
Type a higher number in the Shadows field and press ENTER.
1
2
On the Advanced menu, click Adjust Exposure.
1
2
On the Advanced menu, click Adjust Exposure.
Do one of the following:
Do one of the following:
l
l
Drag the Highlight slider down.
l
l
Drag the Shadow slider down.
Type a lower number in the Highlights field and press ENTER.
Type a lower number in the Shadows field and press ENTER.
1
2
On the Advanced menu, click Adjust Exposure.
1
2
On the Advanced menu, click Adjust Exposure.
Click Auto to return the midtone, highlight, and shadow settings to
Click Auto to return the midtone, highlight, and shadow settings to
the defaults for this slide or negative.
the defaults for this slide or negative.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Using accessories
85
Viewing RGB values and pixel color
You can view the RGB values and pixel color for any spot in an image,
color or grayscale, using the RGB Meter.
1
2
On the Advanced menu, click Adjust Exposure.
Move the cursor over the area in the item for which you want to see
the values. The values appear in the RGB area. A line appears in
the histogram to show you where those pixels occur.
Download from Www.Somanuals.com. All Manuals Search And Download.
86
Using accessories
Back to TOC
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
87
Troubleshooting and maintaining
5
This section provides information for:
l
Solving issues that might occur while using the scanner or
HP scanning software, or issues with the appearance of scanned
l
l
l
Cleaning and maintaining the scanner and accessories. See
For issues that occur during installation or the first time you scan, see
the Setup and Support Guide.
Download from Www.Somanuals.com. All Manuals Search And Download.
88
Troubleshooting and maintaining
Back to TOC
Checking the basics
If the scanner is not working, always perform these actions first.
l
l
l
Check that the power cable is securely connected between the
scanner and a live electrical outlet or surge protector.
If the power cable is connected to a surge protector, make sure the
surge protector is plugged into an outlet and turned on.
Check that the interface cable is securely connected between the
scanner and the computer.
Note:
The scanner has ports for other interface connections,
and a parallel cable might have been shipped in the box
with the scanner. However, for Macintosh computers,
use the universal serial bus (USB) cable.For more
information, see the Setup and Support Guide.
l
l
l
Make sure the scanner is unlocked. Move the lock to the unlocked
position. (Some models only, see "Front panel and accessories
Disconnect the power cable from the scanner and turn off the
computer. After 30 seconds, reconnect the power cable to the
scanner and then turn on the computer, in that order.
If a program has frozen, close it. Press OPTION+
(COMMAND KEY)+ESC, and then click Force Quit.
If these steps did not resolve the issue, see "Starting troubleshooting"
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
89
Starting troubleshooting
Start here to find the information you need. Choose one of these
general groups of issues, and then choose one of that group’s more
specific issues.
l
l
l
There is an issue with the ADF, other than pages jamming. See
l
l
l
A message is on the scanner or the computer. Follow the
directions in the message to resolve the issue.
There is an issue with the XPA. See "Resolving issues with the
There is no message. See "Resolving issues that did not
There is an error message on the front panel liquid crystal
l
l
l
l
Scanned images do not look good. See "Resolving issues with
Printed copies do not look good. See "Resolving issues with
Slides or negatives do not look good. See "Resolving issues with
Download from Www.Somanuals.com. All Manuals Search And Download.
90
Troubleshooting and maintaining
Back to TOC
Resolving scanner messages
Resolving issues that did not generate
messages
(Some models only, see "Front panel and accessories comparisons"
on page 3.) If an error message appears on the 16-character front
panel LCD on your scanner, look for the cause and solution in this
section.
If the scanner or software is not working but no message appears, look
for the cause and solution in this section.
Items you scanned previously are no longer on the computer.
ADF Paper Jam
The scanned image might not have been saved as a file. If you
send an image directly to a destination, the scanned image is not
saved on the computer. When you use the HP Precisionscan Pro
software, use Save As to save the image to your computer.
Clear the paper jam. If the error message does not clear, unplug
the scanner and plug it back in.
The scanner lamp stays on.
Error ##
The scanner lamp should time out and turn off automatically after a
period of inactivity.
The scanner reported an error during the self-test.
Unplug the scanner and plug it back in. If this error message is still
on the scanner, contact HP support. Visit the HP support website
at:
l
l
If you have recently used the scanner, wait a few more minutes.
If the scanner lamp is still on, you might have selected the
Faster Scan setting. Check this setting on the Lamp tab in the
HP Scanjet Controls control panel. See "Setting scanner lamp
See the Setup and Support Guide for phone contact information.
l
l
Press the Power Save button on the front panel of the scanner
to immediately turn off the scanner lamp and the XPA light
Scanner Locked
(Some models only, see the "Front panel and accessories
comparisons" on page 3.) The scanner is not working because it is
locked. Make sure the scanner is unlocked. Move the lock to the
unlocked position. If the error message does not clear, unplug the
scanner and plug it back in.
If you still encounter problems with the scanner lamp or the
Power Save button, contact HP Customer Support.(See
“Contacting HP Customer Support” in the Setup and Support
Guide.)
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
91
I saved a scanned image to a file, but now I cannot open the file in
the program I want.
When I choose Scan To on the scanner, the image does not appear
in the software.
You might have saved the file in a format the other program cannot
use. Save the file in a different format the program can use. Look in
the File Open or Import command for the program to see which
file types it supports.
l
A cable might be loose. Check that the interface cable is
securely connected.
l
You might have accidentally turned off the preview feature.
Check this setting on the Scanner tab in the Preferences of the
HP Precisionscan Pro software. See "Setting preferences" on
The scanner is not working.
l
(Some models only, see the "Front panel and accessories
comparisons" on page 3.) Check that the HP Precisionscan Pro
software is the program set to start when you press the Scan To
One or more of these issues might be causing the problem:
l
l
l
The scanner was not installed properly.
button (
).
The interface cable is not compatible with the scanner.
If the scanner is emitting a grinding sound, the scanner is
locked.
1
2
3
Choose Control Panels from the Apple ( ) menu, and
then choose HP Scanjet Controls from the submenu.
Guide.
Click the Buttons tab in the HP Scanjet Controls dialog
box, and then click the Scan To tab.
Make sure HP Precisionscan Pro is selected in the
Destinations pull-down menu.
The scanner does not scan right away.
If the scanner has not been used for a while, the scanner lamp has
turned itself off. The lamp goes through a warm-up period after you
start the software or press any scanner button. Wait for a few
seconds for scanning to begin.
Scanner is scanning items very slowly.
l
l
l
If you are scanning to edit text, the optical character recognition
(OCR) program causes the scanner to scan more slowly, which
is normal. Wait for the item to scan.
When I press a button on the scanner, the incorrect program opens.
Some default settings can cause the scanner to scan more
slowly. Check the settings. See "Setting preferences" on
Check which function is set to open when you press the button on
The resolution might be set too high. Return to the default
Download from Www.Somanuals.com. All Manuals Search And Download.
92
Troubleshooting and maintaining
Back to TOC
The correct menu items do not appear in the HP Precisionscan Pro
software.
l
l
l
If you used the ADF and then disconnected it, restart the
software.
If you were using the XPA, on the Scan menu, click Scanner
Glass to scan from the glass again.
If you are trying to use the XPA and the XPA (Slides) or XPA
(Negatives) commands are unavailable, restart the software
while the XPA light source is connected to the scanner.
The scanner is making a loud clicking or grinding noise.
The scanner is locked. Move the lock to the unlocked position.
(Some models only, see the "Front panel and accessories
The scanner does not save multiple pages as a single file.
l
If you are scanning from a scanner button, make sure the
Prompt for Another Page option is selected in the HP Scanjet
Controls control panel. See "Configuring scanner buttons" on
l
If you are scanning from the HP Precisionscan Pro software,
make sure the Enable Scan Another Page Dialog option is
selected in the HP Precisionscan Pro Preferences dialog box.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
93
Scanned images have black dots or streaks in top and bottom
margins.
Resolving image-quality issues
This section contains information for resolving image-quality issues,
whether you scanned using the scanner glass, the ADF, or the XPA.
l
l
l
There might be ink, glue, correction fluid, or some other substance
on the scanner glass. Clean the scanner glass. See "Cleaning the
Resolving issues with scanned images
This section contains solutions to issues that affect all scanned
images, regardless of whether you used the scanner glass or the ADF.
If you were printing, see also "Resolving issues with printed copies" on
Scanned images have unwanted lines through them.
Scanned images are too light or too dark.
l
l
The scanner glass might be dirty. Clean the glass. See
If you are using the ADF, the ADF glass might be dirty or
scratched. Clean the ADF glass. See "Cleaning the ADF glass"
The original image might be very light or dark or be printed on
colored paper. Adjust the midtone, highlight, and shadow settings
from the HP Precisionscan Pro software. See "Scanning from HP
Download from Www.Somanuals.com. All Manuals Search And Download.
94
Troubleshooting and maintaining
Back to TOC
Scanned image is not clear.
In the HP Precisionscan Pro software, all of the image scanned when
I only wanted part, or vice versa.
The selection area might not be selected correctly. Make sure the
selection border is surrounding the area you want in the final scan.
Scanned images are crooked.
The item might have been placed crookedly or shifted when you
closed the lid. Straighten the original on the scanner glass and
scan again.
l
l
The resolution, sharpening, or midtone, highlight, and shadow
settings might need to be adjusted before scanning. See
The original might be on colored paper. If the original was
printed on a colored paper, including brown recycled paper, the
image or text might not be clear. Try adjusting the resolution and
midtone, highlight, and shadow settings from the
HP Precisionscan Pro software. See "Scanning from HP
I thought I made the image smaller or larger before the final scan in
the HP Precisionscan Pro software, but it is still the same size as the
original.
You might have zoomed in or out, which does not change the size
of the image. Change the output size. See "Resizing (output
The image is completely black or completely white.
An original photo was fuzzy, and the scanned image looks even
worse.
The item might not be placed correctly on the scanner glass or in
the ADF. Make sure that the item you are trying to scan is placed
face down on the glass, or face up in the ADF.
The sharpening level needs to be increased. In the
HP Precisionscan Pro software, adjust the sharpening. See
Colors in the scanned image are different from the original item.
Scanners, monitors, printers, and different operating systems
interpret color differently. Use the hue and saturation settings in the
HP Precisionscan Pro software to adjust the colors.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
95
Scanned images are grainy, jagged, or fuzzy.
Images scanned from the HP Precisionscan Pro software are larger
than the original when viewed or printed from another program.
l
You resized the image in a program other than the
HP Precisionscan Pro software. Resize the image in the
HP Precisionscan Pro software before you send it to the other
The other program did not accept the image size information. Scan
the image at a lower resolution. When you scan at a resolution the
program accepts, it will display or print the image at the correct
size.
l
l
In the HP Precisionscan Pro software, the resolution is set too
low. Set the resolution to a higher number, or return to the
The image is too big or too small.
In the HP Precisionscan Pro software, too much or too little
sharpening was applied. Adjust the sharpening. See
In the HP Precisionscan Pro software, set the physical output
An original photo had marks, flaws, or scratches, and the scanned
image looks even worse in the HP Precisionscan Pro software.
When I try to scan to the Web from the HP Precisionscan Pro
software, the image is too large or does not look good on screen.
l
You sharpened the image manually. Return to the default
Scan settings for this image might be set incorrectly. See "Tips for
l
Best Quality Sharpening is selected. Check the setting. See
I set the image to a higher resolution in the HP Precisionscan Pro
software, but the output quality is no better.
l
Setting the resolution to a higher number does not necessarily
improve quality. The software sets the resolution automatically
based on the type of item you scanned. Keep or return to the
image quality" on page 69 for guidelines.
l
If you sent the image to another program, the program might not
support the resolution you set in the HP Precisionscan Pro
software. Determine the setting the program uses and set the
resolution in the HP Precisionscan Pro software to that
resolution.
Download from Www.Somanuals.com. All Manuals Search And Download.
96
Troubleshooting and maintaining
Back to TOC
Vertical white stripes appear on the page.
Resolving issues with printed copies
Use this section to help resolve issues with printed pages.
Parts of the page around the edges are not printing.
l
l
The printer might be out of toner or ink. Print a different file from
another program to the printer to see if the issue lies with the
printer.
The scanner internal mirror might be contaminated. Contact the
Customer Service Center for service.
Printers cannot print right up to the edge of the paper. To get the
image to fit inside the printable area, you must slightly reduce the
size of the image in the HP Precisionscan Pro software and then
reprint the image.
The bottom of the printed page is blank, or part of a graphic is cut
off.
Copies are too light.
The page might be too complex. (The printer does not have
enough memory to process the page.) Set the resolution of the
image to 300 dpi or less in the HP Precisionscan Pro software. See
l
If you are copying an item printed on colored paper, there might
not be enough contrast between the ink and paper colors. Adjust
the highlights, shadows, midtones, and resolution settings from
the HP Precisionscan Pro software. See "Scanning from HP
Precisionscan Pro" on page 39. Or, adjust the contrast from the
HP Scanjet Copy Utility. Also, if possible for text, use originals
printed with black ink on white paper.
l
The printer might be out of toner or ink. Print a different file from
another program to the printer to see if the issue lies with the
printer.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
97
Colors in printed images are incorrect.
The output type or printer settings might not be correct. Choose a
different output type and print again. Check the printer settings. If it
is a color printer, check if the printer is out of ink or toner.
Scanned images are jagged or fuzzy.
l
The output type in the HP Precisionscan Pro software might not
be set correctly. Set the output type to True Color or Grayscale.
l
If you placed the image in a file in another program, resized the
image, and are printing from that program, resizing the image in
the program probably caused the issue. Resize the image in the
HP Precisionscan Pro software before placing it in a file in
another program. See "Resizing (output dimensions)" on
l
If the original image was fuzzy and you enlarged it, the fuzziness
becomes more obvious.
Download from Www.Somanuals.com. All Manuals Search And Download.
98
Troubleshooting and maintaining
Back to TOC
The scanned image shows a colored tint, usually pink.
Resolving issues with slides and negatives
The image was probably scanned without the XPA, or the
positioning plate and XPA light source were placed incorrectly on
the scanner bed. For the steps for scanning 35 mm slides or
Use the following section to help resolve issues with slides or
negatives scanned using the XPA. All actions must be performed in the
HP Precisionscan Pro software, because you must scan slides or
negatives using this software. See also "Resolving issues with the
Scanned images appear as a box with multi-colored vertical lines or
as a dashed box with an arrow surrounding the area.
I tried to enlarge a scanned image of a slide, but the image
remained the same size.
The positioning plate might be placed incorrectly on the scanner
bed. Place the positioning plate on the scanner glass so the
Hewlett-Packard logo is at the bottom right.
You might have used the Zoom In command, which only changes
the view on the screen. Use the Resize command to change the
size of the final scanned image. See "Resizing (output
The scanned image is black even though the light on the XPA light
source is on.
l
The positioning plate might be placed incorrectly on the scanner
bed. Place the positioning plate on the scanner glass so the
Hewlett-Packard logo is at the bottom right.
The colors are incorrect, or the image is too light or too dark.
l
The software might be setting exposure for the entire area
instead of one slide or negative. Create a selection area around
the slide or negative you want to use to ensure it is exposed
correctly.
l
Check the Adjust Exposure command in the Advanced menu.
There are streaks in the scanned image.
l
l
l
The positioning plate is not placed completely on the scanner
glass. Make sure the positioning plate is completely on the
scanner glass.
l
Check the original slide or negative for damage.
l
The XPA may be broken, and service may be required.
If you are scanning fewer than three slides with the XPA, make
sure to use the slide light shield to cover the remaining area in
the slide holder. This ensures that no extra light affects the scan.
The scans are dark.
If you are scanning fewer than four negative frames with the
XPA, make sure to use the negative light shield to cover the
remaining area in the negative holder. This ensures that no extra
light affects the scan.
The bulb in the XPA light source might be broken or not working. If
the bulb is broken, service is required.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
99
Converted text does not appear in my word-processing program.
Resolving issues with editable text
Do one of the following:
l
If you used the HP Precisionscan Pro software, send the
scanned image to a text or text-and-image file format. See
This section contains resolutions to issues that might occur when you
are trying to make text editable.
l
Cut and paste the text into the program you want. If the text is
still not editable, work with the text as an image or retype it.
Scanned text is not editable.
l
If you used the HP Precisionscan Pro software, send the
scanned image to a text or text-and-image file format. See
I do not know how to process text using a different OCR program.
Do one of the following:
l
If you used the HP Precisionscan Pro software, you sent the
scan to an image file or saved the scan using an image output
type. Send the scan to a text file. See "List of file types" on
page 62. Or open the image file from the OCR software. See the
documentation for the OCR software.
l
l
l
Scan the item from the OCR program using TWAIN or the HP
Scanjet Plug-in. See "Scanning from other programs" on
Scan the item to the HP Precisionscan Pro software, save the
scanned image as an image file, and open the file in the other
OCR program.
Scanned text is editable in some programs but not in others.
Scan to the HP Precisionscan Pro software. Then, on the Scan
menu, click Scan To and choose the other OCR program.
Some programs accept only image formats and do not allow text.
Make sure the program accepts editable text.
Incorrect characters appear in the text that was converted using the
OCR software.
The accuracy of the OCR program depends on the program having
the correct settings on the quality of the original item. To obtain the
best possible results, choose the scan setting for text, and process
only crisp, clear text. See "What to expect from OCR programs" on
Download from Www.Somanuals.com. All Manuals Search And Download.
100
Troubleshooting and maintaining
Back to TOC
The converted text did not retain font size and style when the text was
placed in a word-processing program.
Word-processing programs cannot always accept the original
formatting of the scanned text. Reformat the text in the word-
processing program.
Converted text appeared in the word-processing program without its
formatting and I wanted it, or vice versa.
Even if you want to retain the formatting and you have the setting
set correctly, the receiving word-processing program cannot
always accept the formatting. Reformat text in the word-processing
program.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
101
When I press the E-mail button on the scanner, the incorrect e-mail
program opens.
Resolving issues sending to destinations
Check which e-mail program is set to open when you press the
Use this section to resolve issues sending images to destinations. Not
all functions are available on all scanners.
E-mail button (
) on the scanner. See "Changing settings for
When I choose E-mail on the scanner, scanned images do not
automatically appear in a new e-mail message.
When printing copies from the scanner or the HP Scanjet Copy
Utility, I cannot choose the printer I want.
The e-mail program is Web-based or might not be supported. Save
the scanned image as a file and attach it to your e-mail message
as you normally do.
Do one of the following:
l
Make sure the printer is set up and configured correctly in the
Chooser. (For more information about using the Chooser, see
the Mac OS Help on your computer.)
When I choose E-mail on the scanner, the scanned image attaches as
a bitmap, but it contains text I want the recipient to be able to edit.
l
Scan the item to the HP Precisionscan Pro software and print
from there.
To make text editable for a recipient, make sure the correct output
type is selected in the HP Scanjet Controls control panel.
When printing copies, I can only make multiple copies of one page
at a time (I cannot collate copy).
1 Choose Control Panels from the Apple ( ) menu, and then
choose HP Scanjet Controls from the submenu.
Even if you are using an ADF, each page is treated as a separate
job. You can make multiple copies of one page, but not multiple
copies of different pages and collate them.
2 Click the Buttons tab in the HP Scanjet Controls dialog box,
and then click the E-mail tab.
3 Select the e-mail program, and then click either Text or Text
and Image.
4 Close the HP Scanjet Controls dialog box.
Or, save the scanned image as a file and attach it to a message as
you normally do.
Download from Www.Somanuals.com. All Manuals Search And Download.
102
Troubleshooting and maintaining
Back to TOC
When I choose the Scan To button on the scanner, the image does
not appear in the software.
When I try to send a scanned image using the Scan To command on
the Scan menu of the HP Precisionscan Pro software, the program I
want does not appear.
l
A cable might be loose. Check that the interface cable is
securely connected.
The HP Precisionscan Pro software might not recognize the
program as a destination. Do one of the following:
l
You might have accidentally turned off the preview feature.
Check this setting on the Scanner tab in the Preferences of the
HP Precisionscan Pro software. See "Setting preferences" on
l
Rebuild the desktop on the computer. To rebuild the desktop,
press (COMMAND KEY)+OPTION while restarting the computer.
(For more information, see the Mac OS Help on your computer.)
l
Check that the HP Precisionscan Pro software is the program
l
l
l
Save the scanned image in a file type the other program uses,
and then open the file in the other program.
set to start when you press the Scan To button (
).
1
2
3
Choose Control Panels from the Apple ( ) menu, and
then choose HP Scanjet Controls from the submenu.
Copy and paste or drag-and-drop the image into the other
program.
Reinstall the program that is not being recognized. This might
allow the HP Precisionscan Pro software to recognize it.
Click the Buttons tab in the HP Scanjet Controls dialog
box, and then click the Scan To tab.
Make sure HP Precisionscan Pro is selected in the
Destinations pull-down menu.
I tried to scan an image into an existing file, but the scanned image
appeared in a new file instead.
Some programs only allow scanned images to be placed into new
files. Cut and paste the image into the file you want. Or, save the
scanned image as a file and import it into the other program.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
103
I want to start scanning from another program, such as my word-
processing program, so I can bring an image into my open file, but I
cannot start the scan.
I am trying to return a scanned image to a program that supports
TWAIN or the HP Scanjet Plug-in, but the image will not appear.
The program that supports TWAIN or the HP Scanjet Plug-in might
not accept the resolution or output type you selected. Rescan the
image using the default settings the HP Precisionscan Pro
software sets for the image.
The other program must support TWAIN or the HP Scanjet Plug-in.
If you cannot find a command such as Acquire or Insert, check the
documentation for the program to see if it is compliant.
If the program supports the HP Scanjet Plug-in and you cannot
start a scan from another program, reinstall the HP Scanjet Plug-in:
I do not see the destinations I want when I use the Select Destination
button next to the Scan To button.
1
2
Quit the program with which you want to use the plug-in.
(Some models only, see the "Front panel and accessories
Insert the HP Scanning Software CD into your computer's CD-
ROM drive. The HP Scanning Software window appears. (If the
HP Scanning Software window does not appear, double-click
the icon for the HP Scanning Software CD.)
Not all destinations appear in the scanner’s destination list. For
example, printers, e-mail programs, and saving to a file are not
included. The list is also limited to the first 18 destinations found by
the HP scanning software. You can access additional destinations
program" on page 60 for more information, or do one of the
following.
3
4
In the HP Scanning Software window, double-click the HP
Scanjet Plug-in folder.
Drag the HP Scanjet Plug-in (which is named HPScanjet) to the
appropriate location for the program with which you want to use
the plug-in. (Many programs have a specific folder for plug-ins.
For information about where to place the plug-in, see the
documentation provided with the program.)
l
l
Unplug the scanner and plug it back in.
5
Start the program with which you want to use the plug-in.
If the program does not support TWAIN or the HP Scanjet Plug-in,
do one of the following in the HP Precisionscan Pro software:
l
Save the scanned image as a file and then insert the file into the
other program.
l
l
Click Scan To from the Scan menu, and choose a program.
Copy and paste or drag-and-drop the image into the other
program.
Download from Www.Somanuals.com. All Manuals Search And Download.
104
Troubleshooting and maintaining
Back to TOC
When using the XPA, I cannot scan using the scanner buttons.
Resolving issues with accessories
The XPA is not designed to work with the scanner buttons. Use the
HP Precisionscan Pro software when using the XPA.
This section contains information for resolving issues when you are
using the XPA or ADF.
There is no light or only a dim light in the transparency adapter after
checking XPA (Slides) or XPA (Negatives) in the Scan menu.
Resolving issues with the XPA
l
Make sure you have selected XPA (Slides) or XPA (Negatives)
from the Scan menu in the HP Precisionscan Pro software. If
these two commands are unavailable, restart the software while
the XPA light source is connected to the scanner.
This section contains issues that might occur when you are using the
XPA. See also "Resolving issues with slides and negatives" on
l
The bulb in the XPA light source might be broken or not working.
With the XPA light source connected to the scanner, hold the
XPA light source up and look for illumination. If the bulb is
broken, service is required.
The XPA is not working at all.
The XPA cable might not be connected correctly. Make sure the
XPA cable is connected securely to the XPA port on the scanner.
When using the XPA, I cannot choose XPA (Slides) or XPA
(Negatives) on the Scan menu.
l
The XPA cable might not be connected correctly. Make sure the
XPA cable is connected securely to the XPA port on the scanner.
l
If you connected the XPA light source while the HP
Precisionscan Pro software was running, restart the software.
Doing so allows the software to detect the XPA.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
105
When using the ADF, the scanner does not feed the item at all.
Resolving issues with the ADF
The hatch might not be securely latched. Open the hatch, and then
on page 108 for illustrations.
This section contains issues that might occur when you are using the
automatic document feeder (ADF).
The ADF is feeding multiple sheets, skewing pages, or jamming
frequently.
An item loaded in the ADF keeps jamming.
l
l
If the pages look like they are skewing as they feed into the ADF,
check the resulting scanned images in the software to ensure
they are not skewed.
l
The item might have something on it. Make sure you have
removed anything such as staples and self-adhesive notes on
l
l
The item might not be placed correctly. Straighten the item and
adjust the guides to center the stack.
l
l
The item is too small. The ADF can handle items as small as
88.9 by 127 mm (3.5 by 5.0 inches). Use the glass to scan.
The maximum number of pages the ADF input tray and output
bin can hold is 25, depending on the type of media being loaded.
Make sure to load only 25 or fewer pages in the input tray, and
remove pages from the output bin if they are stacking up to a pile
of more than 25.
The item is too large. The ADF can handle items as large as 216
by 355.6 mm (8.5 by 14 inches). Use the glass to scan the item
in sections.
l
The item loaded might not meet the specifications for the ADF.
Make sure the type of media being loaded meets required
Download from Www.Somanuals.com. All Manuals Search And Download.
106
Troubleshooting and maintaining
Back to TOC
The bottom of the scanned image is cut off.
After starting a scan from the Copy button using the ADF, the
scanned image is reduced on the printed page and extra space
appears around the scanned image.
l
l
l
The ADF can handle items up to 355.6 mm (14 inches) long. If
the item is longer, scan it in sections on the glass. If the item is
the correct length, choose the correct page size setting in the
ADF dialog box prompt before scanning.
When using the Copy button, the ADF page size settings are not
sent automatically to the printer. Set the page size in the Page
Setup dialog box on the computer:
If sent to a printer, the item might be too complex (require too
much memory) for the printer to process. If possible, choose a
printer with more memory. Or, select a lower resolution or
different output type, like black and white or grayscale.
1
In the Application menu (located in the upper-right corner of
the screen), choose Finder.
2
3
In the File menu, choose Page Setup.
If you are scanning from the scanner buttons, make sure the
correct page size for the ADF is selected in the HP Scanjet
Controls control panel:
Choose the appropriate page size in the Paper pull-down
menu.
4
Click OK.
1
Choose Control Panels from the Apple ( ) menu, and
then choose HP Scanjet Controls from the submenu.
For more information about setting the page size, see the Mac OS
Help on your computer.
2
Click the Buttons tab in the HP Scanjet Controls dialog
box, and then click the tab for the scanner button you are
using.
3
In the ADF Page Size section of the dialog box, select the
setting that corresponds to the pages you are using with the
ADF.
4
Close the HP Scanjet Controls dialog box.
Note:
If you use a different scanner button with the ADF and
encounter this problem again, follow these steps to set
the correct page size for that button.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
107
Faster Scan
Setting scanner lamp controls
After the scanner lamp has turned off, it must warm up again before
the scanner can begin scanning. (This warm-up process takes about
30 seconds.) As a result, the time it takes to scan an item immediately
after the scanner lamp turns on is longer than the time it takes to scan
subsequent items.
You can set the scanner lamp to use either Energy Save or Faster
Scan. These scanner lamp controls are available in the
HP Scanjet Controls control panel.
To help prevent scanning delays caused while the scanner lamp is
warming up, you can enable Faster Scan. This setting allows you to
set a time (such as the beginning of your business day) when the
scanner lamp automatically turns on. The scanner lamp stays on for
ten hours and then turns off.
Energy Save
While using Energy Save, the scanner lamp stays on as long as the
software is running and might stay on for a while after the software is
closed. However, after about ten minutes, the scanner lamp turns off.
Because the scanner lamp stays on, even if you are not using the
scanner or the software, the scanner uses more energy when Faster
Scan is enabled.
Because the scanner lamp turns off, the scanner conserves energy
when Energy Save is enabled. (Energy Save is the default setting for
the scanner.)
1
Choose Control Panels from the Apple ( ) menu, and then
choose HP Scanjet Controls from the submenu.
1
Choose Control Panels from the Apple ( ) menu, and then
choose HP Scanjet Controls from the submenu.
2
3
4
In the HP Scanjet Controls dialog box, click the Lamp tab.
Click Faster Scan.
2
3
4
In the HP Scanjet Controls dialog box, click the Lamp tab.
Click Energy Save.
In the Select Time text box, type the time when you want the
scanner lamp to turn on daily.
When finished, close the HP Scanjet Controls dialog box.
5
When finished, close the HP Scanjet Controls dialog box.
Download from Www.Somanuals.com. All Manuals Search And Download.
108
Troubleshooting and maintaining
Back to TOC
3
If the item cannot be easily removed, lift the two green tabs located
behind the rollers and gently remove the green paper lead as
shown.
Clearing jams from the ADF
Pages can jam at the beginning or the end of a page. Use the
appropriate procedure below to clear the jam and continue.
1
Raise the hatch.
Note:
Using force to remove the page might cause damage to
your originals. If the majority of the paper is already
through the main roller, use the procedure to clear jams
at the end of a page.
2
Lift the large green tab (located to the left of the roller) and gently
remove the jammed page.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
109
4
Remove the jammed item from the ADF and replace the paper
lead.
6
Restack all pages and reload them into the ADF.
7
On the ADF prompt on the computer, reselect any settings you had
5
Close the hatch. Press down firmly until you hear a click.
changed and click Scan To or Scan again.
Download from Www.Somanuals.com. All Manuals Search And Download.
110
Troubleshooting and maintaining
Back to TOC
4
If you still cannot remove the paper from the ADF, lift the ADF lid to
its fully open position, loosen the jammed paper from the roller at
the rear of the ADF lid, and pull it gently from the ADF.
1
2
Remove any pages from the ADF input tray.
Remove the input tray from the ADF.
5
When you have successfully cleared the jam, attach the input tray
and close the hatch. Press down firmly on both sides until you hear
a click.
3
Gently pull the paper out of the ADF in the feeding direction
(towards you).
6
7
Restack all pages and reload them into the ADF.
On the ADF prompt on the computer, reselect any settings you had
changed and click Scan To or Scan again.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
111
Cleaning and maintaining
1
2
3
Disconnect the power cable from the scanner.
Open the scanner lid.
Periodically, the scanner and accessories might need to be cleaned or
to have maintenance, especially if you are seeing marks or smudges
on scanned images.
Clean the glass using a soft, lint-free cloth sprayed with a mild
glass cleaner.
CAUTION
Only use glass cleaner. Avoid abrasives, acetone,
benzene, and carbon tetrachloride, all of which can
damage the scanner glass. Avoid isopropyl alcohol
because it can leave streaks on the glass.
Cleaning the scanner glass
You might need to clean the scanner glass if the ink on items you are
scanning can be smudged with your hand or items have excessive
amounts of dust or dirt on them. You might also need to clean the
scanner glass if there are smudges or other marks on scanned
images.
4
5
Dry the scanner glass with a dry, soft, lint-free cloth.
When finished, reconnect the power cable to the scanner.
Fingerprints or smudges on the underside of the glass do not affect the
appearance of scanned images because this area of the glass is
outside the focal point of the scanner.
Download from Www.Somanuals.com. All Manuals Search And Download.
112
Troubleshooting and maintaining
Back to TOC
3
Clean the glass using a soft, lint-free cloth sprayed with a mild
glass cleaner.
Cleaning the XPA
(Some models only, see "Front panel and accessories comparisons"
on page 3.) Clean the XPA with a dry, soft cloth. If necessary, spray the
cloth with window cleaner or isopropyl alcohol.
CAUTION
Only use glass cleaner. Avoid abrasives, acetone,
benzene, and carbon tetrachloride, all of which can
damage the scanner glass. Avoid isopropyl alcohol
because it can leave streaks on the glass.
4
5
Dry the scanner glass with a dry, soft, lint-free cloth.
Cleaning the ADF glass
When finished, reconnect the power cable to the scanner.
(Some models only, see "Front panel and accessories comparisons"
scanning.
Fingerprints or smudges on the underside of the glass do not affect the
appearance of scanned images because this area of the glass is
outside the focal point of the scanner.
1
2
Disconnect the power cable from the scanner.
Open the scanner lid and locate the ADF glass area on the
scanner bed.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Troubleshooting and maintaining
113
Uninstalling the software
Other resources, support, and
specifications
The Uninstall option of the Installer allows you to remove the scanning
software from your computer.
The Setup and Support Guide contains information about these topics:
l
Setup instructions and troubleshooting. Find setup instructions
and troubleshooting information for issues that can arise when you
install the scanner.
1
2
Unplug the scanner, and then restart the computer.
l
Resources. Discover websites and other tools that contain
scanning tips, updated drivers, and the latest information about
your HP scanner.
Note:
If you do not unplug the scanner and restart the
computer before you uninstall the software, some files
are not removed from your computer during the
uninstallation.
l
l
Support. Locate the contact information for your region if you need
to contact HP.
Insert the HP Scanning Software CD into your computer's CD-
ROM drive. The HP Scanning Software window appears. (If the HP
Scanning Software window does not appear, double-click the icon
for the HP Scanning Software CD.)
Warranty and Specifications. See this topic for the warranty and
product and regulatory information.
The Setup and Support Guide is located on the CD in the folder for
your language, or on your computer in the HP Scanning Software
folder.
3
4
Double-click the HP Scanning Software Installer, and then follow
the instructions on the screen.
When the main installation dialog box appears, select Uninstall
from the pull-down menu (located in the upper-left part of the dialog
box).
Also, see the HP PrecisionScan Pro Read Me file for late-breaking
information about the HP Precisionscan Pro software. This file is
located in the same folder as the Setup and Support Guide.
5
6
7
Click Uninstall.
Follow the instructions on screen.
After the uninstall finishes, quit the HP Scanning Software Installer.
Download from Www.Somanuals.com. All Manuals Search And Download.
114
Troubleshooting and maintaining
Back to TOC
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
115
Using software commands and controls
A
This section contains information for using the shortcuts, toolbars, and
cursors in the HP Precisionscan Pro software.
The HP Precisionscan Pro contains keyboard shortcuts and toolbars to
give you quick access to software commands. The Info bar provides
information about the scanned image, and the context-sensitive
cursors provide information on the type of activity you can perform in
the scanning software.
Download from Www.Somanuals.com. All Manuals Search And Download.
116
Using software commands and controls
Back to TOC
Using keyboard shortcuts and the menus
Scan
New Scan
This section summarizes the menus and commands in the
HP Precisionscan Pro software that you can select using the
keyboard.
Start (preview) a new scan.
+N
+T
Scan To...
Scan and send to a destination, such as
e-mail
Scan to CD
Save scanned photos or documents on a
CD-writer drive.
Apple (
) menu
Return Image To
When using TWAIN or the HP Scanjet
Plug-in, return the scanned image to the
other program.
About HP Precisionscan
Pro
View information about the program,
version, and copyright.
Save As...
Save the selection area as a file.
+S
+P
Page Setup...
Change how printed pages are set up,
including page orientation and paper size.
Print...
Scan and print the selection area.
Scanner Glass
XPA (Slides)
Select the source from which to scan. Only
one can be selected.
XPA (Negatives)
Settings
Save...
Save settings.
Load...
Load (use) settings.
Preferences...
Quit
Change scanning default preferences.
Close the HP Precisionscan Pro software.
+Q
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Using software commands and controls
117
Edit
Output Type
True Color
Reset Tools
Return all settings except output type to
the defaults for this image.
+Z
+C
+A
Optimized Palette
Web Palette
Copy
Scan and place the selection area on
the Clipboard.
Choose the output type. Only one can
be selected.
System Palette
Spot Color
Select All
Unselect All
Select the entire scanner glass
(including blank space).
Remove the selection border.
Grayscale
Black & White Bitmap
Automatically Set Type
Allow the software to select the output
type based on the contents of selection
area.
View
Zoom In
Zoom in on the selection area.
Zoom out to the original view.
Zoom Out
Tools
Rotate the image counterclockwise by
90 degrees.
Rotate Left 90°
Rotate the image clockwise by 90
degrees.
Rotate Right 90°
Mirror
Reverse the image side-to-side.
Resize
Resize the selection area. This
changes the output file size also.
Change Resolution
Sharpen
Change the resolution of the final
scanned image.
Adjust the sharpening.
Download from Www.Somanuals.com. All Manuals Search And Download.
118
Using software commands and controls
Back to TOC
Advanced
Help
Adjust Color
Adjust colors (hue) and their intensity
(saturation).
Show Balloons
Hide Balloons
Turn on and turn off Balloon Help.
If you are using Balloon Help, Hide
Balloons appears. If you are not using
Balloon Help, Show Balloons appears.
Adjust Exposure
Adjust the contrast (midtones), detail in
light areas (highlights), and detail in
dark areas (shadows).
HP Precisionscan Pro 3.1
Help
View the Help for the HP scanning
software.
+?
Adjust Black & White
Invert Colors
Adjust which values in the image will be
represented as black or white.
HP Scanjet on the Web
Connect to the Internet and visit the
HP Scanjet website.
Make colors in the image their
opposites.
Product Tour
View the product tour.
Descreen
In the scanned image, reduce the
appearance of undesirable patterns
that are in a printed original.
User’s Manual
View the printable user’s manual in PDF
format.
Enable All Smart Friends
Disable All Smart Friends
Allow helpful alerts to appear when
potential problems arise.
Prevent helpful alerts from appearing
when potential problems arise.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Using software commands and controls
119
Toolbar
HP Precisionscan Pro tool and information
bars
The HP Precisionscan Pro software displays a toolbar containing
shortcut buttons for common commands.
The HP Precisionscan Pro software contains a toolbar and an Info bar
to help you use commands quickly or find information about the current
scanned image.
Click this button
New Scan
To
Start (preview) a new scan.
Scan To...
Perform a final scan and send to a destination,
such as e-mail.
Scan to CD
Save As...
Print
Scan and save the selection to rewritable CD.
Save the selection area as a file.
Scan and print the selection area.
Return Image To...
When using TWAIN or the HP Scanjet Plug-in,
return the scanned image to the other program.
Copy
Scan and place the selection area on the
Clipboard.
Zoom In
Zoom in on the selection area.
Zoom Out
Zoom out to the original view.
Rotate Left 90
Rotate Right 90
Rotate the image counterclockwise by 90 degrees.
Rotate the image clockwise by 90 degrees.
Download from Www.Somanuals.com. All Manuals Search And Download.
120
Using software commands and controls
Back to TOC
Info bar
Undo Editing
Changes
Return all settings except output type to the
defaults for this image.
The info bar appears at the bottom of the preview window and displays
the following information:
l
l
l
l
l
the width of the output image
the height of the output image
scale of the output image
the output type currently selected
one of the following:
l
A progress bar that shows when the scanner is scanning or the
scanning software is processing a command.
l
The number of KB (kilobytes), MB (megabytes), GB (gigabytes),
or TB (terabytes) in the image in the selection area. This size is
only an estimate of the actual size of the image. The file can be
larger or smaller than the value shown here. The size of a saved
file depends on the format used to save the file.
l
an XPA icon, if the XPA (Slides) or XPA (Negatives) commands
are selected in the Scan menu
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Using software commands and controls
121
Context-sensitive cursors
Ready for activity
Click a menu item and select a command.
Click a list button to select an option.
Click a button to turn it on or off, or to increase or
decrease a number.
The shape of the pointer indicates the type of activity you can perform
in the scanning software.
New selection
area
Draw a new selection area.
Data entry
accepted
Click, then type a value.
Move selection
area
Drag the selection area to a new location in the
preview area.
Drag the selection area to another program.
Press OPTION and drag the selection area to the
desktop or a folder.
Highlight
eyedropper
Position this cursor over a light area in the image to
see its pixel value in the RGB meter and the
histogram. Click on pixels to set them as the
Highlight value. In the Transparency Exposure
Adjustment tool, click to set the RGB value.
Resize selection
area horizontally
Appears on the sides of the selection area. Drag
the cursor to resize the width of the selection area.
Resize selection
area vertically
Appears on the top or bottom of the selection area.
Drag the cursor to resize the height of the selection
area.
Shadow
eyedropper
Position this cursor over a dark area of the image to
see its pixel value in the RGB meter and the
histogram. Click on pixels to set them as the
Shadows value.
Resize selection
area diagonally
Appears on the corners of the selection area. Drag
the cursor to resize both the height and width of the
selection area.
Eyedropper and
the “no” symbol
Indicates this area is an area in which pixel value is
not available.
Download from Www.Somanuals.com. All Manuals Search And Download.
122
Using software commands and controls
Back to TOC
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
123
Glossary
B
symbols
The program you are currently using or that is currently selected. A
program’s title bar changes color to distinguish active from inactive
programs.
Used to represent black-and-white photos accurately. These grayscale
images contain 256 shades of gray.
See automatic document feeder.
Or XPA. See transparency adapter.
See automatic document feeder.
Color images composed of three 8-bit color channels. When
combined, the red, green, and blue channels provide up to 16 million
colors. This is also referred to as true color.
a
A command offered by programs that support TWAIN or the HP
Scanjet Plug-in. Selecting Acquire takes you directly to the selected
scanning software, and then returns the scanned image to the
requesting program.
The piece of glass on the scanner bed that the ADF uses to scan
documents from the feeder tray.
Download from Www.Somanuals.com. All Manuals Search And Download.
124
Glossary
Back to TOC
b
The visibly jagged steps along angled lines or object edges that result
from sharp tonal contrasts between pixels. Seen in both black-and-
white images and color images. Sometimes called Jaggies.
The number of bits used to define the shade or color of each pixel in an
image. A 1-bit image is black and white. An 8-bit grayscale image
provides 256 shades of gray. An 8-bit color image provides 256
indexed colors and is associated with a specific palette or color table.
A 24-bit image provides over 16 million colors. The greater the bit
depth, the larger the size of the saved file. See also file size.
A technique that smooths transitions between pixels, reducing the
jaggedness of curved lines.
Reflects the amount of disk space a scan would require if saved to
your computer. Approximate Size value does not apply if the output
type for the scan is set to text; it only applies to an image
representation of the scan.
A type of black-and-white, gray, or color image or picture made up of a
matrix of individual pixels or dots. Often referred to as raster, raster
bitmap, or raster image.
Black & white raster bitmaps contain only black pixels and white pixels,
no colors or shades of gray. Each pixel represents one bit.
Automatic cropping displays only the item(s) detected on the scanner
bed, not any of the surrounding area.
The Black & White Threshold tool lets you change the dividing point for
black-and-white pixels in an image that uses the Black & White Bitmap
(raster) output type. All pixels below the threshold will be output as
black, and all pixels above the threshold will be output as white.
Abbreviated ADF, it is an optional accessory that allows you to scan
multiple pages.
A feature of the scanning software that automatically applies the
optimal output resolution to the selection area. For example, output
resolution is automatically set to 200 when the True Color output type
is selected, and set to 300 for the Black & White Bitmap (raster) output
type.
A line surrounding the scanned image indicating scanning boundaries.
Clicking the image reveals a selection border and handles that are
used to define the scanning region.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Glossary
125
The balance of light (highlights) and dark (shadows) in an image. In
black-and-white images, the lower the brightness, the closer the image
will be to black. The higher the brightness, the closer the image will be
to white. Brightness should not be confused with contrast, which
measures the range between the darkest and lightest shades in an
image. Brightness determines the intensity of shades in an image,
while contrast determines the number of shades in the image.
The red, green, and blue components from which colors are created.
The process of adjusting an image to compensate for input and output
device characteristics or color flaws in the original image.
c
The number of colors that a monitor can display at once. Most
Macintosh monitors can display in 256 grays, 256 colors, thousands of
colors, and millions of colors. The higher the color depth, the more
lifelike images look on screen.
To press and release the mouse button once.
A tool used to adjust the color balance and hue.
Pixels in an image that are extremely light or extremely dark and that
would lose detail when the image is printed or displayed.
The ability to adjust settings that determine how the scanner buttons
and scanning software perform operations.
Cyan, Magenta, Yellow, Black. The color model in which all colors are
composed of Cyan, Magenta, and Yellow, the primary colors of
pigments like ink, plus Black. Printers use CMYK to print in color.
Context-sensitive Help answers questions related to the currently
displayed window. The Help is provided in four ways: Text Labels,
ToolTips, Info bar messages, and Help commands.
Text that has been rendered into digital format by an OCR program.
The range between the lightest and darkest shades in an image. An
image with high contrast has few gray shades between black and white
and appears to be dominated by stark light and dark tones. An image
The preservation of balance between colors throughout the tonal
range. Color balance is particularly important when scanning objects
that include neutral tones (grays) or large areas of consistent color.
Download from Www.Somanuals.com. All Manuals Search And Download.
126
Glossary
Back to TOC
with low contrast has many shades of gray and tends to look flat and
dull. Change contrast using the highlight, shadow, and midtone
settings.
The file, program, or hardware device where the scanned image will be
used. Examples include a printer, a Web page, or an e-mail program.
This range determines the number of bits used for exposure
compensation, shadow detail, and black-and-white threshold
adjustment displays. The higher the bit depth, the finer the level of
control in adjusting these image manipulation functions.
Software that the system uses to communicate with devices, such as a
display, printer, mouse, or scanner.
The number of pixels that a computer monitor can display both
horizontally and vertically. Screen resolutions are typically 640 x 480
(VGA), 800 x 600 (super VGA), or 1024 x 786.
To eliminate portions of an image from the final scan.
d
The process of approximating pixel colors when reducing the color
depth of an image. Dithering can improve transitions between colors
when reducing a 24-bit image to 8-bit format.
Predetermined settings in the scanning software that define levels on
your behalf. Default settings in the HP Precisionscan Pro software are
set for Output Type, Output Resolution, Color, Exposure, Black &
White Threshold, and Sharpen Level. You can override default
settings.
For the purposes of this documentation, document refers to an original
item containing text or both text and images. It also means an original
item scanned using the automatic document feeder.
The ability of a material to absorb or transmit light. The greater the
density of a material or object, the more black it contains. This applies
to both black-and-white images and color images.
See dpi.
To press and click a mouse button twice in rapid succession.
The process of removing an unwanted pattern, such as a moiré
pattern, that appears in a printed original so the pattern does not
appear in the scanned image.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Glossary
127
Dots Per Inch. The number of dots in a linear inch. DPI measurements
are used to describe the resolution of printers and scanners, where
printed images and words are made up of a series of round dots. The
greater the DPI number, the higher the resolution.
A network over which you can transfer messages and electronic files.
E-mail is also sent via Internet browsers.
To save a file in a particular file format for use in other programs.
To move an object on screen. Place the cursor over the image or
selection area, hold the mouse button down, and move the mouse to
move the object.
The amount of light, or brightness and contrast, in an image.
f
To move an object to a new location and keep it there. Click on the
object and drag it to a new location, such as an open document in
another program, and release the mouse button. When dragging-and-
dropping between programs, a copy of the object is placed in the
receiving program.
The format in which a scan is saved. Certain file formats enable
programs such as word processors to insert, open, or import scans.
Common graphics formats include JPG, GIF, and TIFF. Common text
formats include plain text and RTF (Rich Text Format).
A list of items that appears when you click on or pass the cursor over a
command such as File or Edit.
The number of bytes in a file. The file size of scanned images is
determined by resolution, file type, output type, and scaling. To reduce
the file size of photographs, for example, you could decrease bit depth
or resolution.
e
Text that is converted from a scanned image into characters you can
modify in a word processor or other text-editing program. Depending
on the capabilities of your program, you can change the font, size,
style, and other attributes of editable text, as well as edit words or
phrases.
The actual image, defined by the selection area, that is sent to a
destination such as a file, a printer, the Clipboard, or another program.
The approximate height and width of the final image to be scanned.
Download from Www.Somanuals.com. All Manuals Search And Download.
128
Glossary
Back to TOC
The Flowed Text option converts output into one column, placing
images as closely as possible to the appropriate text.
Refers to images, pictures, or photographs in which individual pixels
are relatively large and have areas of white between them, thus
reducing the overall perceived quality of the image. Graininess can
occur when you scan a poor-quality original or reduce the bit depth of
the scanned image by dithering or halftoning.
The Framed Text option places text and images in a frame, positioned
as closely as possible to the way they appear in the original document.
Text may be more difficult to edit extensively since the frames may not
expand to hold additional text.
A graphic file format that is supported by many programs. Files saved
in this format support 256 colors.
Refers to the sharpness of an image.
An original or output type containing shades of gray, not just black and
white. In a grayscale image, each pixel contains multiple bits of
information, allowing more shades of gray to be recorded and
displayed. Four bits can reproduce up to 16 levels of gray, and eight
bits can reproduce 256 shades of gray. Grayscale is commonly used
for black-and-white original photographs but is also effective in
maintaining shading in pencil drawings.
The area on the front of the scanner hardware containing the buttons
for sending an item to a destination or changing settings.
g
h
The contrast that affects the mid-level grays or midtones of an image.
Adjusting the gamma of an image allows you to change the brightness
values of the middle range of gray tones without dramatically altering
the shadows and highlights. This applies to both black-and-white
images and color images. The default setting of 2.2 ensures integrity
among computer systems.
An original composed of a pattern of dots that tricks the eye into seeing
shades of gray or color. Halftones are common in all printed materials.
Scanning halftones instead of photographic originals can result in
lower final image quality.
The vertical dimension of a scan as it will appear at its destination.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Glossary
129
The lightest portion of an image, usually reproduced as white on the
computer screen or when printed.
The distinctive characteristic of a visible color that enables you to
distinguish it from other colors. Six hues are especially important in
photography, scanning, and printing: red, yellow, green, cyan, blue,
and magenta. Hue is determined by the frequency of the wave of light
that creates the color. See also saturation.
A graphical representation of the concentration of pixels at each
intensity or gray level in the selection area of the scanned image.
Histograms help determine the optimal highlight, shadow, or threshold
value of an image.
i
An electronic picture that can be displayed on a computer screen or
saved to a disk.
A software utility used to select number of copies, destination printer,
and other copy options.
A program that lets you modify bitmapped drawings and photographs.
The scanning software that HP provides for previewing an image
before sending it to a destination; making changes, such as resolution,
resizing, and contrast; and saving images as files.
The size of the image expressed in bytes and displayed in the Info bar.
File size and image size may vary, depending on the file type.
A Photoshop plug-in for image editor and OCR programs, which allows
you to scan text and images from within these programs.
To bring a scanned image into a document from another program.
An automated feature that sends scanned images directly to a
destination on the Web.
A form of assistance that appears in the lower, left corner of the screen
and displays the width and height of the output image, the scale
percentage, the output type currently selected, and the size of the
output image.
HyperText Markup Language. A language used in creating documents
for the World Wide Web. Documents can be saved in HTML.
Download from Www.Somanuals.com. All Manuals Search And Download.
130
Glossary
Back to TOC
The connection between the scanner and the computer. This can be
either a USB, parallel, or SCSI connection depending on the model of
scanner and your operating system.
Joint Photographic Experts Group. A compressed file format that
reduces file size and enables faster file access. This format can reduce
image quality and performance when the file is decompressed and
recompressed.
k
Resolution that is changed in the scanning software rather than in the
hardware. For example, if your scanned image is 600 dpi, you might be
able to enhance it to 1200 dpi in the scanning software. This is useful
for enlarging small images.
A keystroke or combination of keystrokes that allows you to quickly
accomplish common tasks.
The process of increasing the resolution of an image by the addition of
new pixels throughout the image, the colors of which are based on
neighboring pixels.
l
The orientation of a photograph or image that is wider than it is tall.
When an image is taller than it is wide, it is called portrait orientation.
To reverse the colors in an image (for example, in a black-and-white
image, black areas are turned white and white areas are turned black).
m
The physical drawing, photo, collage, etc. you place in the scanner to
scan. Once it is scanned, it is referred to as an image or scanned
image.
This option enables higher bits per pixel when the scan is sent to the
software. When it is off, 8 bits per pixel are returned for grayscale and
24 bits for color. When it is turned on, 16 bits per pixel are returned for
grayscale and 48 bits for color.
j
Refers to the uneven transition between black and white, or areas of
color, in a scanned image. Jagged edges can be avoided by scanning
at a higher resolution than your output device, or by not scaling the
image after scanning it.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Glossary
131
The gray shades of an image. Midtones are usually between 30% and
70% black. Midtone control adjusts the brightness of gray levels in the
image so that the lightest and darkest portions of the image can be
properly displayed on your monitor. The higher the setting, the brighter
the image appears on your monitor.
This option reduces the noise (unwanted specks) in an image by
applying software algorithms to minimize the effects of noise in the
scanner electronics.
o
Color images that are composed of three 8-bit color channels. When
combined, the red, green, and blue channels provide up to 16 million
colors. Sometimes referred to as “true color” and “24-bit color.”
See optical character recognition.
Abbreviated OCR. A technology that recognizes letters in a scanned
image and converts them into ASCII characters, or editable text.
An undesirable pattern in color printing that results from incorrect
screen angles of overprinting halftones. Moiré patterns usually result
when you scan a halftone, when you scan images taken directly from a
magazine, or when you scale an image in an image editor after it is
scanned.
The true resolution of a scanner, the resolution at which the scanner
captures images. See also interpolated resolution, resolution.
n
A palette or color table that contains the pixel colors present in an
image.
This XPA piece holds negative strips for scanning. Insert it into the
slide holder on the bottom of the XPA light source for proper scanning
of negatives.
The original document or picture to be scanned.
The file that is generated by the scanning process.
This XPA piece blocks excess illumination and improves image quality
when scanning negatives. Slide it into the negative holder after the
chosen negative strip.
Download from Www.Somanuals.com. All Manuals Search And Download.
132
Glossary
Back to TOC
The actual height and width of an image when saved. You will not see
the size changes to your image in the Preview area since image size
affects only the final scan.
Apple's proprietary image file format that is used by the Mac OS.
Designed for the screen, this format is best used for color images that
will not be printed. Images saved as PICT files are smaller in size than
images saved as a TIFF files.
The type of file that is generated during the scanning process. Output
type reveals the bit depth of the image.
The smallest element (picture element) that can be assigned an
independent color and intensity and can be displayed on a computer
screen. Pixels are square dots arranged in a grid pattern to make up
the images displayed on the screen.
p
A subset of the color look-up table that establishes the colors that can
be displayed on the monitor at a particular time. The only color depth
that allows multiple palettes is the 256 (or 8-bit) color setting for your
monitor. At a color depth of 256 colors, each program (or even each
individual image used or edited in a program) can have a different
color palette.
A module that integrates into a program to provide additional
functionality. The HP Precisionscan Pro Installer adds a Photoshop
plug-in (the HP Scanjet Plug-in) for image editor and OCR programs
that allows you to scan text and images from within these programs.
Portable Network Graphics format. A compressed image file format
suitable for the Web that might replace GIF because of copyright
issues with GIF format. PNG is non-lossy compressed, supports
interlacing, and can be used with the True Color output type, which
GIF cannot.
The flashing that occurs when your monitor is set to a color depth of
256 colors and you switch programs. When you switch programs, the
palette of the active program becomes the system palette, and all other
programs redraw themselves as accurately as possible with the new
colors.
A menu of items that appears when you click on or pass the cursor
over a command.
Portable Document Format (PDF) format. Adobe Acrobat files use this
format.
Orientation of a photograph or image that is taller than it is wide. An
image that is wider than it is tall is called a landscape orientation.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Glossary
133
This XPA piece is a large template with a rectangular cutout that
orients proper placement of the XPA light source on the scanner bed.
A measurement of the number of dots per inch (dpi) the printer is
capable of printing. Typical laser printers have resolutions of 600 dpi,
typical ink printers have resolutions of 300 dpi for photographs and 600
dpi for text, while imagesetters have resolutions of 1200 or 2400 dpi.
The more dots per inch, the smoother the output and the greater the
number of grayscale levels and colors the device can describe.
Term for scanning items directly to a website.
An energy conservation method that reduces power consumption
when the scanner is idle for a period of time.
The product tour provides an overview of the scanner’s capabilities
and how scanning tasks are completed. It appears each time the
scanning software starts, unless it is specifically disabled. It is also
available in the Help menu.
Pixels Per Inch. A measurement of resolution for monitors and
scanners where the individual element is a square pixel.
q
r
Refers to your preferred method of using the scanner. The scanning
software automatically saves certain preferences, such as the location
of toolbars and the destination of a scan, that it detects during normal
use of the scanner. Some preferences are restored each time the
scanner is used, while others are maintained only throughout a
scanning session.
A type of black and white, gray, or color image or picture made up of a
matrix of individual pixels or dots. This is also referred to as a bitmap.
The measure of how many dots per inch (dpi) are scanned, displayed,
or printed. The greater the dpi, the greater the amount of detail that is
visible, and the larger the file size. The final output device (monitor,
printer) for a scanned image determines the resolution of the image.
For example, if you scan a picture at 600 dpi (the optimum) and your
printer is capable of printing at only 300 dpi, the printed image will be
no more than 300 dpi.
A feature that displays a scanned image so you can view it in the
scanning software. You can then select an area to be saved; make
adjustments to the tone, color, and size; and save the final image.
The rectangular area in the software where the scanned image is
displayed.
Download from Www.Somanuals.com. All Manuals Search And Download.
134
Glossary
Back to TOC
Red, Green, Blue. The color model in which every color is composed
of a varying amount of red, green, and blue, which are the three
primary colors of light. RGB is used to display colors on a computer
monitor.
The glass surface of the scanner where you place items to scan.
Sometimes referred to as the scanner glass.
The glass surface on the scanner where you place items to scan.
Sometimes referred to as the scanner bed.
A format for text files. Rich Text Format preserves all formatting in the
original text document. It converts formatting into instructions that
compatible programs can interpret.
The lid, or cover, of the scanner, which holds the original paper flat for
scanning.
To rotate the entire scan 90 degrees clockwise or 90 degrees
counterclockwise.
Scanning (or scan) sources include the flatbed, transparency-slides,
and transparency-negatives.
s
The measurement of the number of lines per inch (lpi) that a screen
can display. This is usually 72 lpi.
The intensity of color in a specific hue. An image with high color
saturation has vivid color. A black-and-white photograph has zero
saturation. See also hue.
Saving settings allows you to save a set of settings used with one
scanned image and reuse the settings with an image scanned in the
future.
To reduce or increase the physical size of an image while maintaining
aspect ratio (the ratio of the horizontal dimension to the vertical
dimension).
The area inside the rectangular border drawn around a portion of the
image in the Preview area. The selection area is scanned when you
drag-and-drop, save to a file, copy to the clipboard, or print.
To capture a picture, photograph, or text as a digital electronic image
using a scanner. This term also refers to the image that has been
scanned.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Glossary
135
The darkest area of an image, usually reproduced as near black on the
computer screen or when printed. The range between highlight and
shadow determines the quality and color differentiation in the image.
The list of destinations available when configuring the Scan To button
options in the HP Scanjet Controls control panel. This list of
destinations appears in place of the standard Scan To button options
and allows the settings for each available destination to be set from
one dialog box, rather than by selecting each destination separately
from a pull-down menu. Speed Destinations are available with some
scanner models.
To enhance the detail in an image.
This XPA piece holds slides for scanning. It is attached to the bottom of
the XPA light source.
A software function that finds large areas of color in a scanned image
and applies a uniform color to the area.
This XPA piece blocks excess illumination and improves image quality
when scanning slides. Slide it into the slide holder after the chosen
slide(s).
An international color standard and the default color system used for
all HP peripherals, the World Wide Web, and most office software.
A palette or color table containing a Web palette plus more shades of
gray and the 16 VGA colors.
Smart Friends are tips that appear automatically to notify you of
potential problems. For example, if you are setting a very high
resolution but want to use e-mail to send the scanned image, a Smart
Friend would alert you that the file will probably be too large to send in
e-mail.
t
As it relates to scanning, text is saved in the following formats: plain
text, HTML, and RTF.
The program from which an image is retrieved for use in a document.
Programs that support TWAIN or the HP Scanjet Plug-in pull an image
from a source, such as the HP Precisionscan Pro software.
The process of rendering all areas darker than a set value as black,
and all areas lighter than a set value as white. Useful when converting
grayscale images to black and white.
Download from Www.Somanuals.com. All Manuals Search And Download.
136
Glossary
Back to TOC
Tagged Image File Format. A bitmapped file format for images,
capable of storing up to 24-bit depth images. TIFF file format is
especially appropriate for scanned images and is supported by many
programs and computers.
An industry-standard communications protocol for sending instructions
to hardware (such as a scanner) and receiving image data back from
them. If you are using a program that supports TWAIN, you can start
the HP Precisionscan Pro software directly from that program.
u
Tagged Image File Format, compressed. A bitmapped file format for
images, capable of storing up to 24-bit depth images. TIFF file format
is recommended for scanned images and is supported by many
programs and computers. TIFF compressed files use data
compression to reduce the size of the resulting file.
A method of stretching or shrinking an image proportionately in both
the vertical and horizontal directions.
Universal Serial Bus. An interface for connecting peripherals, such as
scanners, to a computer.
The overall effect produced by the combination of lighting, shade, and
color.
v
The area that contains buttons for a program's controls.
A type of image that uses algebraic equations to define the various
lines and curves of the image.
Abbreviated as XPA. An optional accessory used to scan negatives
and slides. An XPA connector is plugged into the scanner, and a
template is used to position the transparency above the glass.
w
An image type that is rendered with 24-bits per pixel per color.
A palette or color table containing red, green, and blue pixel colors that
is standard for images embedded in Web pages or HTML files. It
consists of 216 entries of all combinations of the values 0, 51, 102,153,
204, and 255.
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
Glossary
137
The horizontal dimension of your scan as it is sent to its destination.
x
See transparency adapter.
This XPA piece is a light that plugs into the scanner. It fits into the
positioning plate and provides backlighting in order to properly scan
transparent slide and negative images. (It may also be used as a light
box for viewing slides.)
y
z
The ability to enlarge, or magnify, the image in the Preview area so that
finer adjustments can be made to the image. This action does not
enlarge the picture that is saved, printed, copied to the Clipboard, or
dragged into another program.
Download from Www.Somanuals.com. All Manuals Search And Download.
138
Glossary
Back to TOC
Download from Www.Somanuals.com. All Manuals Search And Download.
139
Index
ADF (automatic document feeder)
capacity 105
A
saturation 56
shadows 52
alerts
highlight 53
shadow 53
Apple Menu
approximate size
definition 124
viewing 120
attachments, e-mail
creating 31
black and white bitmaps
definition 124
black and white copies
black and white images
cleaning
ADF 112
scanner 111
XPA 112
clipped pixels
definition 125
color balance
adjusting 56
definition 125
color channels
changing 58
cleaning 112
loading 78
black and white threshold
changing 57
definition 124
borders, selection
troubleshooting 105
Adjust Black & White command
shortcuts 118
definition 125
color copies
using 57
Adjust Color command
shortcuts 118
using 56
naming 32
definition 124
moving 42
boxes
making 33
color correction
automatic 72
automatic cropping
Adjust Exposure command
highlights 51
midtones 50
shadows 52
adjusting
backgrounds 54
brightness 50
contrast 46
definition 124
settings 38
brightness
adjusting 50
definition 125
Buttons tab, HP Scanjet Controls
accessing 35
definition 125
color depth
B
balance, color
adjusting 56
definition 125
bed, scanner
definition 125
color wheel
definition 125
highlights 51
hue 56
definition 134
colored paper
midtones 50
C
colors
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
140
definition 126
cursors
context-sensitive 121
dragging-and-dropping 66
Ready 121
Typing 121
customer support
customizing
definition 28
options 37
Speed 8, 36
troubleshooting 99
E-mail button
locating 26
troubleshooting 101
using 32
e-mailing scans
inverting 49
troubleshooting 94, 97
contrast
adjusting 46
definition 125
copies, making
troubleshooting 101
details
enhancing 52
dimensions
display resolution
definition 126
troubleshooting 101
exposure
D
dark areas
troubleshooting 101
Copy button
locating 27
troubleshooting 106
using 33
Copy command
shortcuts 117, 119
using 65
copying and pasting
correction, color
adjusting 52
adjusting 50
definition 127
eyedropper tools
black 52
white 51
troubleshooting 93
decreasing
saturation 56
default settings
definition 126
depth, color
dragging-and-dropping
definition 127
F
file formats
automatic 72
definition 125
supported 91
E
definition 125
Descreen command
settings 71
shortcuts 118
editable text
definition 127
websites 64
file sizes
definition 127
reducing 23
cropping
using 59
destinations
languages 73
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
141
files
lost 90
film, scanning
negatives 81
definition 123
glass, scanner
cleaning 111
definition 134
graphics
Share-to-Web 64
shortcuts 116
starting 40
tools 45
sharpening 48
increasing
details 52
saturation 56
slides 79
uninstalling 113
troubleshooting 98
final scans
definition 127
flowed text
grayscale
8-bit 123
input tray, ADF
loading 78
HP Scanjet Plug-in
definition 129
troubleshooting 103
using 74
HTML file formats
definition 129
using 62
hue
adjusting 56
definition 129
troubleshooting 105
interface connection
definition 130
Invert Colors command
shortcuts 118
definition 128
definition 128
preferences 73
framed text
using 49
H
Help, online
printing 15
J
jagged images
definition 130
troubleshooting 97
jams, ADF
definition 128
preferences 73
fuzzy images
using 40
highlights
adjusting 51
alarms 53
definition 129
I
clearing 108, 110
preventing 105
JPEG files
definition 130
using 62
images
sharpening 48
troubleshooting 95, 97
darkening 50
K
G
histogram 55
definition 129
gamma
HP Precisionscan Pro software
features 39
definition 128
GIF files
definition 128
using 62
glass, ADF
cleaning 112
lightening 50
mirroring 47
resizing 45
rotating 47
L
lamp
modes 107
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
142
light areas
shortcuts 117
using 47
definition 131
adjusting 51
mirroring images
More Options button
locating 27
troubleshooting 99
online Help
P
light bulbs
light shield
negatives 81
pages, multiple
scanning 28
palettes
definition 132
optimized 131
slides 80
using 35
printing 15
using 40
Optimized Palette
definition 131
system 135
web 136
paper
paper jams, ADF
clearing 108, 110
preventing 105
loading items
multiple pages
scanning 28
ADF 78
N
negative holder
M
definition 131
using 81
negative light shield
definition 131
using 81
negatives
scanning 81
troubleshooting 98
New Scan command
using 41
options
PDF files
Photo Reprint button
locating 26
making copies
troubleshooting 101
Maximum Pixel Depth
definition 130
destinations 37
Resolution 72
text 73
original items
preparing 17
output dimensions
changing 45
definition 132
output types
using 30
photos
option 71
troubleshooting 95
pixel color
midtones
noise reduction
definition 131
Number of copies button
locating 27
adjusting 50
definition 131
definition 132
viewing 55
using 33
options 38
Mirror command
O
OCR
selecting 43
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
143
troubleshooting 95
restoring defaults
Return Image To command
shortcuts 119
using 74
reversing images
color 49
layout 47
RGB values
definition 134
viewing 55
rich text format (RTF)
definition 134
using 62
Rotate Left command
using 47
Rotate Right command
using 47
Scan To button
locating 26
positioning plate, XPA
definition 133
Q
quality, troubleshooting
copies 96
slides 79
Power Save button
locating 27
R
removing
using 34
Scan To command
shortcuts 116, 119
using 60
Scanjet Plug-in
preferences
definition 133
previewing scans
frames 75
definition 129
resetting
resolution 46
Resize command
shortcuts 117
using 45
resizing
troubleshooting 103
using 74
scanner bed
definition 134
scanner buttons
Copy 33
Print command
shortcuts 116, 119
using 63
rotating images
printing
copies 33
RTF (rich text format)
definition 134
documentation 15
scans 63
troubleshooting 101
programs
E-mail 32
identifying 26
settings 35
troubleshooting 91
scanner glass
using 62
images 45
troubleshooting 23
resolution
S
saturation
adjusting 56
definition 134
e-mail 31
automatic 23
cleaning 111
changing 46
definition 133
interpolated 130
printers 133
Save As command
using 61
saving to files
definition 134
scanning
troubleshooting 91
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
144
negatives 81
saving 69
slide light shield
definition 135
Text 73
previewing 41
slides 79
shadows
adjusting 52
using 80
slides
scanning 79
troubleshooting 98
viewing 80
software
uninstalling 113
specifications
ADF 17
speed
Speed Destinations
using 36
templates
negative 81
slides 79
troubleshooting 98
text, editable
languages 73
screen resolution
definition 134
selecting
alarms 53
definition 135
troubleshooting 99
TIFF files
histogram 55
Share-to-Web button
locating 26
using 30
spot color
definition 136
selection areas
automatic 72
creating 42
cursors 121
definition 134
moving 42
resizing 42
Sharpen command
shortcuts 117
using 48
sharpening
definition 135
images 48
shield, light
negatives 81
slides 80
shortcuts
keyboard 116
menu 116
toolbar 119
size
slide holder
definition 135
using 62
sRGB
definition 135
starting scans
tools
support, customer
System Palette
transparency adapter (XPA)
cleaning 112
sending to programs
troubleshooting 102
settings
automatic 22
destinations 37
lamp 107
using 79
troubleshooting
ADF 105
checklist 88
copies 96
definition 135
T
tab options
Control 73
Resolution 72
Scanner 71
loading 69
definition 135
using 79
e-mailing 101
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
145
negatives 98
using 80
OCR 99
slides 80
Z
slides 98
Zoom In command
using 43
W
transparencies 98
XPA 104
Web Palette
definition 136
Zoom Out command
using 43
zooming
zooming 23
websites
definition 23
True Color
definition 136
using 44
in 43
out 43
weight
TWAIN programs
definition 136
troubleshooting 103
word processing programs
U
Undo Editing Changes command
shortcuts 120
using 48
X
XPA (Negatives) command
shortcuts 116
using 82
command 42
shortcuts 117
XPA (optional transparency adapter)
cleaning 112
USB
definition 136
using 79
V
viewing
XPA (Slides) command
shortcuts 116
Download from Www.Somanuals.com. All Manuals Search And Download.
Back to TOC
146
Download from Www.Somanuals.com. All Manuals Search And Download.
|