Monogram.
ZISS480DMSS - GE Monogram 48" Built-In Stainless Steel Refrigerator with
Dispenser and Water Filter
THE INSTALLATION SPACE
48" Models 20"
* Shipping height.
The refrigerator
47"
47-1/2
Case Width
can be adjusted to
fit into a cutout that
is 83-1/2” min. to
84-1/2” max. height
Note that the top
case trim at the
front is 1/2” higher
and will overlap
upper cabinetry or
soffit. Use leveling
legs and wheels for
height adjustment.
7"
*84" From
Floor to
Top Frame
Electrical
Area
84 1/2" max
83 1/2" min
Finished
*83-1/2"
at
Rear
5"
74" From Floor
to Bottom
of Electrical
Opening
24"
5"
48"
Frame to Frame
5"
Water Supply
3 1/2"
3 1/2"
Product Clearances
Water And Electrical Locations
These refrigerators are equipped with a 2 position door
stop. The factory set 130° door swing can be adjusted
to 90° if clearance to adjacent cabinets or walls
is restricted.
The opening must be prepared with the electrical and water
supply located as shown.
The cutout depth must be 24".
Designed for industry standard flush installation. The
refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
90° Door Swing
130° Door Swing
20"
15"
23-7/8"
Behind
Frame
The cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed the
24” installation depth shown. The top case trim overlaps the
bottom of the soffit.
28-5/8"
Frameless cabinets:
The case trim overlaps cabinets at the top and sides.
Therefore, frameless cabinets may require filler strips to
prevent interference with cabinet door swing. The opening
must allow for filler strips.
Allow minimum clearances for freezer door and
fresh food door for a full 130° door swing and to
allow for pan removal.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall. Electrical must be
located on rear wall as shown.
4" minimum clearance is required when door
swing is adjusted to 90°. If the 90° door stop
position is used, pan access is maintained, but
pan removal is restricted.
Note: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor or back
wall. The water line should be 1/4" O.D. copper tubing between
the cold water line and
water connection location, long enough to extend
to the front of the refrigerator. Installation of an easily
accessible shut off valve in the water line is recommended.
®
™
For answers to your Monogram, GE Profile or
GE appliance questions, visit our website at
GEAppliances.com or call
®
GE Answer Center service, 800.626.2000.
Specification Revised 2/02