INSTALLATION MANUAL
VEHICLE SECURITY SYSTEM
CE-SS200
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
FUSION CULTURE
• PROGRAMMING REMOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 4
• ALARM FEATURES PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . pg 5
• ADJUSTING THE SENSITIVITY LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . pg 8
• WIRING DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 9
• CENTRAL LOCKING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 11
• SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 15
There’s no point doing something if no one notices. We’ve always
believed the way to make things happen is by getting noticed. From
our product, to our demo cars, to our events, FUSION is about
making some noise.
Now you are ready. Step out of the shadows and announce you’ve
arrived in a world where the old limits are left behind. Where
technology is creatively combined with the latest in product
innovation. Where new levels of entertainment are delivered with
outstanding performance and quality. Our development team create
distinctively different products; subwoofers, amplifiers, speakers and
peripherals that redefine what can be done in car audio.
Leave the old behind and push the limits of what can be achieved in
car audio. Make some noise.
For more information about FUSION Electronics visit our website at
or email [email protected]
RECORD YOUR PRODUCT DETAILS HERE:
MODEL NUMBER _______________________________ DATE OF PURCHASE________________
AFFIX RECEIPT HERE
PROFESSIONAL INSTALLATION STONGLY RECOMMENDED
Installation Precautions:
1. Roll down window to avoid locking keys in vehicle during installation
2. Avoid mounting components or routing wires near hot surfaces
3. Avoid mounting components or routing wires near moving parts
4. Tape or loom wires under hood for protection and appearance
5. Use grommets when routing wires through metal surfaces
6. Use a voltmeter for testing and verifying circuits
V 2.0
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING REMOTES
ALARM FEATURES PROGRAMMING:
ALARM FEATURE “I” PROGRAMMING:
1. Turn the ignition switch ‘OFF/ON’ 3 times (within 15 seconds)
and leave in the ON position.
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds)
and leave in the OFF position on the 3rd time.
2. Push the valet switch 3 times, and hold on the 3rd push until a long
chirp is heard from the siren, and then release the valet switch. You
are now in the remote programming mode.
2. Push the valet switch twice, and hold on the 2nd push until one
short chirp, followed by one long chirp is heard then release the valet
switch. You are now in the alarm feature ‘I’ programming mode.
3. Press and hold any button of the remote until the siren responds
with a confirming chirp, this indicates the remote has been stored
into memory.
3. A; Press and release the remote button corresponding to the
feature ‘1’ to be changed.
The siren will chirp and the LED will indicate the new setting
4. If you have additional remotes (up to 4 in total) that need to be
programmed, repeat step 3 for each remote.
B; Press and release the remote button corresponding to the
feature ‘2’ to be changed.
Exit Programming: Turn ignition to ‘OFF’ position, or wait for 15
seconds. Three long chirps and three indicator light flashes will
confirm exit.
The siren will chirp and the LED will indicate the new setting
C; Press and release the remote buttons
+
corresponding to
the feature ‘3’ to be changed.
Note: This mode will only retain the last 4 remote transmitters
programmed. If the remote memory is exceeded, the security system will
start deleting remote’s from memory in chronological order.
The siren will chirp and the LED will indicate the new setting
Note: The factory default setting is always [1] LED flash, [1] chirp.
Press remote
button
One Chirp / LED one
flash
Two Chirps / LED two
flashes
Factory Default
Setting
Chirps on
Chirps off
1
2
Automatic Rearm On
Automatic Rearm Off
Instant Door Ajar
Warning
45 second Delay Door
Ajar warning
3
+
Exit Programming: Turn ignition to ‘ON’ position, or wait 15 seconds.
Three long chirps will confirm exit.
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ALARM FEATURE “II” PROGRAMMING:
ALARM FEATURE “III” PROGRAMMING:
1. Turn the Ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds),
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds),
and leave in the OFF position.
and leave in the OFF position.
2. Push the valet switch 4 times and hold on the 4th push until two short
chirps and one long chirp is heard, and then release the valet switch.
You are now in the alarm feature ‘II’ programming mode.
2. Push the valet switch 6 times and hold on the 6th push until three
short chirps and one long chirp is heard, and then release the valet
switch. You are now in the Alarm feature ‘III’ programming mode.
3. A; Press and release the remote button corresponding to the
feature ‘1’ to be changed.
3. A; Press and release the remote button corresponding to the
feature ‘1’ to be changed.
The siren will chirp and the LED will indicate the new setting.
The siren will chirp and the LED will indicate the new setting.
B; Press and release the remote button corresponding to the
feature ‘2’ to be changed.
B; Press and release the remote button corresponding
to the feature ‘2’ to be changed.
The siren will chirp and the LED will indicate the new setting.
The siren will chirp and the LED will indicate the new setting.
C; Press and release the remote buttons
+
corresponding to
C; Press and release the remote buttons
+
corresponding to
the feature ‘3’ to be changed.
the feature ‘3’ to be changed.
The siren will chirp and the LED will indicate the new setting.
The siren will chirp and the LED will indicate the new setting.
Note: The factory default setting is always [1] LED flash, [1] chirp.
Note: The factory default setting is always [1] LED flash, [1] chirp.
Press
remote
button
One Chirp /
LED one flash
Factory
Two Chirps /
LED two flashes LED three flashes
Three Chirps /
Press remote
button
One Chirp / LED one Two Chirps / LED
flash
two flashes
Factory Default
Setting
Default Setting
0.9 - second
door lock
pulses
3.0 - second
door lock pulse unlock
double pulse
Shock sensor
program mode
1
2
1
2
Red/white wire =
trunk/boot (Channel
3) output
Red/white wire =
two step door unlock
output
Active arming
Passive arming Passive arming
without passive with passive door
door locking
locking
Anti car jacking off
Anti car jacking on
3
+
Ignition
Without ignition
3
+
controlled door controlled door
locks & unlocks locks & unlocks
Exit Programming: Turn Ignition to ‘ON’ position, or wait for 15
seconds. Three long chirps will confirm exit.
Exit Programming: Turn ignition to ‘ON’ position, or wait for
15 seconds. Three long chirps will confirm exit.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ADJUSTING THE SENSITIVITY LEVEL OF THE SHOCK SENSOR
WIRING DIAGRAM
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds) and
leave in the OFF position.
2. Push the valet switch 6 times and hold on the 6th push until three
short chirps and one long chirp is heard, and then release the valet
switch. You are now in the alarm feature ‘Shock Sensor’
programming mode.
6 Pin
White
6 Pin Mini Connector
Black Antenna Wire
3. Press and hold button for 2 seconds. One long siren chirp will
indicate the unit is ready to accept adjustments of the second stage
of the shock sensor (full alarm).
LED Indicator
2 Pin
White
2 Pin
Blue
Valet Switch
6 Pin Door Lock/Unlock
Wire harness
6 Pin
White
4. Pressing the button on the remote once will decrease the sensitivity
level by one, each time a decrease is made the siren will respond
with one chirp, while 2 chirp’s indicates the minimum sensitivity
setting.
6 Pin
White
Main 6 Pin Wire harness
5. Pressing button on the remote once will increase sensitivity level by
one, each time an increase is made the siren will respond with
one chirp, while 2 chirp’s indicates the maximum sensitivity setting.
6. Hit the bumper or strong metal part of the vehicle to test the
threshold level of the sensor.
a). Activate the warn-away (first stage of the shock sensor), the siren
will emit a short chirp.
b). Activate the full alarm (second stage of the shock sensor), the
siren will emit a long chirp.
A: MAIN 6 PIN WIRE HARNESS:
7. When you are satisfied with the second stage of the shock sensor
settings, press and hold and buttons simultaneously for
2 seconds. Two long siren chirps will indicate the unit is ready
to accept adjustments of the first stage of the shock
sensor (warn-away).
Turn Indicator
10A Fuse
1. White Wire: Turn Indicator Relay Output
2. Red / Blue Wire: Turn Indicator Relay Power input
3. White Wire: Turn Indicator Relay Output
4. Black Wire: Ground to Vehicle FRAME
5. Brown Wire: Positive output To Siren
8. Follow the steps 4, 5 and 6 to adjust the warn-away sensitivity.
9. When you are satisfied with the setting, press and buttons
simultaneously. One long siren chirp indicates the unit has confirmed
the setting.
3A Fuse
6. Red Wire: +12V To Constant Battery Source
Note: If 20 seconds of inactivity expire, or the ignition is turned on during
the above steps, the unit will exit the programing mode and return to the
disarmed mode. Three long chirps will confirm exit.
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
A: CENTRAL LOCKING DIAGRAMS
B: 6 PIN MINI CONNECTOR WIRE HARNESS:
(After market Door Motors)
INSTALLING DOOR LOCK MOTORS (2 WIRE)
Green/ white
Blue/ white
Blue/ red
12V
1. Violet Wire: Positive Door Pin Switch Input
2. Blue Wire: Instant Trigger Ground Input
Green/ red
3. Green Wire: Negative Door Pin Switch Input
4. Yellow Wire: To Ignition Switched + 12V
12V
Blue/ yellow
+12V
Green/ yellow
Cut
30
85 87a 86
From ignition switch
To start solenoid
White wire
5. Orange Wire: 200mA Grounded when armed
Red wire
6. Red/White Wire: (-) 200mA Programmable Output
Channel 3 / 2 Step Door Unlock.
Yellow wire
INSTALLING 4 DOOR LOCK MOTORS (WITH 5-WIRE LOCK MOTOR)
Orange
wire
B lue/ red
G reen/ red
G reen/ w hite
B lue/ w hite
B lue/ yellow
T o D oor
U n lock C ontrol
W ire
T o D oor
Lock C ontrol
W ire
+ 12V
G reen/ ye llo w
C: 6PIN DOOR LOCK/UNLOCK WIRE HARNESS:
(See central locking diagrams)
B: CENTRAL LOCKING DIAGRAMS
(Factory Door Locking System)
Blue/Red Wire: (87a) - Door Unlock Relay
Blue/White Wire: (30) - Door Unlock Relay
Blue/Yellow Wire: (87) - Door Unlock Relay
Green/Red Wire: (87a) - Door Lock Relay
Green/White Wire: (30) - Door Lock Relay
NEGATIVE TRIGGER DOOR LOCK SYSTEM
Master
Locking
Green / white
Blue / white
Switch
Green/Yellow Wire: (87) - Door Lock Relay
Door Lock Door unlock
Green / yellow
Blue / yellow
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
POSITIVE TRIGGER DOOR LOCK SYSTEM
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR 5 WIRE
ALTERNATING DOOR LOCKS
+ 12V
Green / white
Blue / white
Master
Locking
+ 12V
OEM Door Master Lock
87
86
87A
30
Switch
Red / White
85
+12V
Lock
Unlock
Door Lock
Door unlock
+ 12V
Green / yellow
x
Cut the Unlock Wire
Blue / yellow
Green / Red
x
Cut the Existing
Lock Wire
Green / White
Green / Yellow
6-Pin
Door
+ 12V
Lock
Wire
Harness
Blue / Yellow
Blue / Red
OEM Slave
Door Lock
Switch
ALTERNATING DOOR LOCKS
Blue / White
Unlock
Lock
Master Door
Lock Switch
+12V
+12V
Splice
Green/ red
OEM Driver's
Door Lock
Motor
Cut the Existing
Unlock Wire
Green/ white
Blue/ red
X
X
To All Other
Door Lock
Motors
Splice
Cut the
Cut Existing Unlock Wire
Existing
Lock Wire
X
Blue/ white
+ 12V
To Slave Door
Lock switches
Green/ yellow
Blue/ yellow
To Door
Lock
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR GROUND SWITCHED
DOOR LOCKS
OEM Door Master Lock Switch
Red / White
Unlock
Lock
VACUUM OPERATED DOOR LOCKING SYSTEM
Existing
Unlock Wire
Existing
Lock Wire
Green/ white
Blue / Red
Blue/ red
Blue / White
Green / White
6-Pin
Door
Lock
Wire
Green/ red
Door Switch
Green / Yellow
Blue / Yellow
Cut
X
Blue/ white
Green/ yellow
Blue/ yellow
Harness
Compressor
+12V
+12V
OEM Door
Lock Relay
OEM
Door Lock
Motor
X
To All Other
Door Lock
Motor
Cut Existing Unlock Wire
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR POSITIVE SWITCHED
DOOR LOCKS
Power supply:
Operating temperature:
TX Frequency:
10 VDC – 16 VDC
-40 °C – +80 °C (-40 °F – +176 °F )
433.92 M Hz
+12V
OEM Door Master Lock
87
Red / White
Unlock
Lock
86 87A 85
30
Existing Pos.
Unlock Wire
+ 12V
Existing Pos.
Lock Wire
POWER CONSUMPTION:
Indicator light flash output:
Door Lock:
Door Unlock:
15 Amp
10 Amp
10 Amp
15 mA
Blue / Red
6-Pin
Door
Lock
Wire
Blue / White
Green / White
Green / Yellow
Blue / Yellow
Harness
Security system (disarmed):
+ 12V
OEM Door
Lock Relay
Note: Remote control range is dependant on weather conditions and
alarm installation.
OEM Driver's
Door Lock
Motor
THE FUSION CE-SS200 SECURITY SYSTEM COMPLIES WITH:
X
To All Other
Door Lock
Motors
Cut Existing Unlock
FCC:
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions.
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Z105
YOU CAN HELP PROTECT THE ENVIRONMENT!
Please remember to respect the local regulations:
Hand in the non-working electrical equipment
to an appropriate waste disposal center.
PUBLISHED BY FUSION ELECTRONICS LIMITED:
© Copyright 2007 by FUSION Electronics Limited.
All rights reserved. Specifications and design are
subject to change without notice.
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
|