DOPPLER SPEED LOG
Marine Speed and Distance Measuring Equipment (SDME)
DS-80
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY INSTRUCTIONS
CAUTION
Do not use the equipment for other than
its intended purpose.
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
Only qualified personnel
should work inside the
equipment.
Improper use of the equipment can result
in personal injury or equipment damage.
Turn off the equipment immediately if
you feel it is abnormal.
Immediately turn off the power at the
switchboard if water leaks into the
equipment or an object is dropped into
the equipment.
Turn off the power from the switchboard if
the equipment is emitting strange noises
or becomes excessively hot. Contact your
dealer for advice.
Continued use of the equipment can cause
fire or electrical shock. Contact a FURUNO
agent for service.
The useable ambient temperature range
is 15 C to 55 C.
Do not place liquid-filled containers on
the top of the equipment.
Do not use the equipment out of the
above temperature range.
Fire or electrical shock can result if the
liquid spills into the equipment.
Do not place objects around the
equipment.
Do not disassemble or modify the
equipment.
Overheating may result.
Do not power the equipment when the
transducer is in air.
Fire, electrical shock or serious injury can
result.
The transducer may become damaged.
Handle all units carefully.
Keep the equipment away from rain
and water splash.
Fire or electrical shock can result if the
rain or water gets into the equipment.
Damage can lead to corrosion.
Do not use chemical cleaners such as
alcohol, acetone and benzine to clean
the equipment.
Do not operate the equipment with wet
hands.
Electrical shock can result.
Chemical cleaners can remove paint and
markings. Use only a soft, dry cloth. For
stubborn dirt, use a soft cloth moistened
with water-diluted mild detergent.
Keep heater away from equipment.
A heater can melt the equipment's power
cord, which can cause fire or electrical
shock.
When dry docked remove marine life
from the transducer.
Use the proper fuse.
Remove marine life to maintain good
sensitivity.
Fuse rating is shown on the equipment.
Use of a wrong fuse can result in damage
to the equipment.
Do not paint the transducer face.
Further, handle the transducer with
care.
Paint will affect equipment performance.
i
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING LABEL
A warning label is attached to the
Distributor, Transceiver and Terminal
Box. Do not remove the labels. If a
label is missing or is illegible, contact
a FURUNO dealer or agent about
replacement.
Name: Warning Label (1)
Type: 86-003-1011-0
Code No.: 100-236-230
WARNING
To avoid electrical shock, do not
remove cover. No user-serviceable
parts inside.
RECORD OF MODIFICATIONS IN THIS OPERATOR’S MANUAL
Outline of changes in
Operator’s Manual
Pub No.
Software (Prog. No.)
Publicized for submission to type 03I-02J-02K
test BSH
Apr/2000
(DS-800, DS-801,
DS-810)
Publicized for submission to type 6550100003I (DS-800)
test BSH
6550110003J (DS-801)
6550120003K
June/2000
(DS-810)
Modified to conform to IEC
61162-1 Edition 2
2002/4
DS-800: 6550100004
DS-801: 6550110003
DS-810: 6550120003
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
SPECIFICATIONS....................... SP-1
2 OPERATION OF OPTIONAL
EQUIPMENT ..............................12
2.1 Digital Indicator DS-830, Distance
Indicator DS-840............................12
FOREWORD...................................... 1
SYSTEM CONFIGURATION............. 2
PRINCIPLE OF OPERATION............ 3
REMARKS ON USAGE..................... 4
3 MAINTENANCE,
TROUBLESHOOTING................14
3.1 Maintenance ..................................14
3.2 Troubleshooting .............................15
1 OPERATION OF DISPLAY UNIT . 5
1.1 Controls........................................... 5
1.2 Turning the Power On/Off................ 5
1.3 Adjusting Contrast, Panel Dimmer... 6
1.4 Selecting a Display.......................... 6
1.5 Main Menu Operation...................... 7
1.6 Distance Run Operation.................. 7
1.7 System Setting................................ 9
1.8 Demonstration Mode......................11
3.3 Diagnostics, Checking
Program Number ...........................16
4 DIGITAL INTERFACE
(IEC 61162-1 Edition 2)..............17
4.1 I/O Sentences................................17
4.2 Sentence Description.....................20
5 PARTS LOCATION AND
PARTS LIST................................23
Parts Location ......................................23
Parts List..............................................25
CALIBRATION SHEET....................29
MENU OVERVIEW ..........................30
INDEX ..................................... Index-1
Declaration of conformity
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
This page is intentionally left blank.
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS OF THE DOPPLER SPEED LOG
DS-80
1. GENERAL
(1) Speed Range
Fore-Aft: -10.0 to +40 knots through-the-water
0.00 to 999,999.99 nautical miles through-the-water
Water depth greater than 3 m beneath the keel.
1.0 MHz
(2) Distance Run
(3) Working Depth
(4) Working Frequency
(5) Speed Accuracy
(6) Distance Accuracy
1.0% or 0.1 knots whichever is the greater
1.0% or 0.1 nm whichever is the greater
Note:Accuracy is subject to shallow water effects, to the effect of wind, current and tide, and
sensor location. Any ultrasonic equipment having the same frequency may interfere with
speed measurement. The Doppler Log transducer should be installed apart from the
transducers of such kind of equipment.
2. DISPLAY UNIT
(1) Display
Character size 15 or 21 mm H on monochrome LCD
(2) Indication
Ship’s speed
Fore: c**.* knots (+40.0 kt max.)
Aft: d**.* knots (-10.0 kt max.)
******.** nm
Distance run
(3) Other Function
Diagnostic check
3. DIGITAL INTERFACE
(1) Serial Signal
Output:
2 ports; VBW, VLW in IEC 61162-1 (NMEA 0183 Ver 2.0)
1 port; IEC 61162 (NMEA 0183 Ver 2.0)
Speed signal for Analog display: 2 port
-3.3 mA to 10 mA/ -10 kt to +30 kt
Analog current output: 1 port
Input:
(2) Analog Signal
4 mA to 20 mA/ -10 kt to 30 kt
Analog voltage output: 1 port
-3.3 V to 10 V/ -10 kt to 30 kt
(3) Distance run output
(4) System Check signal
2 ports; Contact closure each 0.005 nm, forward speed,
30 VDC: 0.4 A
1 port, 30 VDC: 0.2 A, default: closed
SP - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
4. POWER SUPPLY
(1) System Source
100/110/115/200/220/230 VAC:1.5/0.7 A max., 1 phase, 50-60 Hz
5. ENVIRONMENTAL CONDITION (IEC 60945)
(1) Ambient Temperature -15°C to +55°C (units for protected area)
Analog display: 0°C to +50°C
(2) Relative Humidity
(3) Vibration
95% at 40°C
IEC 60945 adopted
(4) Category of Equipment
Display Unit/Distance indicator/Transceiver Unit:
For protected area
Transducer:
For submerged use, 600 kPa x 12 h
Distributor/Terminal box: For protected area
6. COATING COLOR
(1) Display Unit
Cover: Munsell 2.5GY5/1.5 (light gray), Panel: N3.0 (gray)
(2) Distribution Box
(3) Transceiver Unit
(4) Terminal Box
(5) Analog Display
Munsell 2.5GY5/1.5 (light gray)
Munsell 2.5GY5/1.5 (light gray)
Munsell 2.5GY5/1.5 (light gray)
Munsell 2.5GY5/1.5 (light gray)
7. COMPASS SAFE DISTANCE
(1) Display Unit/Digital Indicator/Digital Distance Indicator
Standard: 0.50 m, Steering: 0.40 m
(2) Transceiver Unit
(3) Distribution Box
(4) Terminal Box
Standard: 2.05 m, Steering: 1.40 m
Standard: 3.10 m, Steering: 2.10 m
Standard: 0.65 m, Steering: 0.45 m
SAFETY PRECAUTION
- There is no unit giving rise to a dose rate > 0.5 mrem/h at 50 mm.
- There is no harmful radiation from the screen.
- All units of this equipment comply with EMC requirements in IEC 60945, as required by IMO
Res. A.813 (19).
SP - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
FOREWORD
Foreword
Features
Thank you for purchasing the FURUNO
DS-80 Doppler Speed Log. We are
confident you will discover why FURUNO
has become synonymous with quality and
reliability.
The FURUNO DS-80 displays ship’s speed
relative to water, using the Doppler
principle; ship’s speed is measured by
detecting the Doppler shift frequency from
the signal returned from the watermass.
Dedicated in the design and manufacture of
marine electronics equipment for half a
century, FURUNO Electric Company has
gained an unrivaled reputation as a world
leader in the industry. This is the result of
our technical excellence as well as our
worldwide distribution and service network.
The output is interfaced with ARPA, AIS,
and other shipborne equipment in IEC
61162-1 format.
The main features of the DS-80 are
• Simple operation. In most cases all that
is required to display ship’s speed is to
turn on the equipment.
Please carefully read and follow the safety
information and operating and maintenance
instructions set forth in this manual before
attempting to operate the equipment and
conduct any maintenance. Your Doppler
speed log will perform to the utmost of its
ability only if it is operated and maintained
in accordance with the correct procedures.
• Pair-beam system effectively reduces
error caused by pitching. The transducer
assembly symmetrically emits two sonic
beams, one fore and the other aft. By
averaging the Doppler shift in both
directions accurate speed data is
available under rough sea conditions.
• Speed and distance information on the
This equipment is designed, produced and
documented by FURUNO Electric Co., Ltd.,
complying with ISO 9001 standards as
certified by the Lloyd’s Register of Quality
Assurance System.
adjustable-contrast LCD display.
• Analog display, digital Indicator and
digital distance indicator display
optionally available.
• Conforms to the following standards: IMO
A.824(19), as amended by MSC.97(72),
IMO A.694(17), IEC 61023, IEC 60945
(3rd edition), IEC 61162-1 (2nd edition)..
1
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM CONFIGURATION
DISPLAY UNIT
DS-800
TERMINAL BOX
DS-802
DIMMER MF-22L-1/MF-22L-2
IEC 61162-1 Input
Power ON SW Signal
Distance Run Signal
IEC 61162-1 Output
DISTRIBUTION BOX
DS-801
DIMMER MF22L-1/MF22-2
DIGITAL INDICATOR DS-830
DISTANCE INDICATOR DS-840
TERMINAL BOX
DS-802
JUNCTION BOX
CI-630
DIMMER MF-22L-1/MF-22-2
115/230 VAC
RANGE SWITCH BOX
DS-389
ANALOG DISPLAY UNIT MF-22A-1
TRANSCEIVER
UNIT DS-810
SHIP'S MAINS
115/230 VAC
: STANDARD SUPPLY
TRANSDUCER
DS-820
: OPTIONAL SUPPLY
: LOCAL SUPPLY
2
Download from Www.Somanuals.com. All Manuals Search And Download.
PRINCIPLE OF OPERATION
The Doppler speed log measures ship's
The relative motion causes the Doppler shift
and the ultrasonic waves reflected at the
watermass (plankton or any underwater
objects) are received at the frequency of fr =
fo + fd where fd is the number of frequency
shifts counted at the receiver circuit. To
calculate ship’s speed, the following formula
is used.
speed by using the Doppler Effect, which is
observed as a frequency shift resulting from
relative motion between a transmitter and
receiver or reflector of acoustic or electro-
magnetic energy. A common example of the
Doppler Effect is a train. When a train is
approaching, the whistle has a higher pitch
than normal. You can hear the change in
pitch as the train passes.
V = fd/fo • c/2sinθ
c: Underwater velocity
The DS-80 has a pair-beam, one directed in
the fore direction and the other in the aft
direction, which emits ultrasonic waves at
an angle of θ to the waterline towards ship’s
fore and aft directions. The frequency of the
received signal is then compared with that
of the transmitted frequency to measure
doppler shift to calculate ship’s speed.
Note that the sound velocity in water
changes with water temperature and water
pressure but the DS-80 readout is
automatically compensated for change by
using a temperature sensor.
V
SEA
SURFACE
f
o
θ
f = f + f
d
r
o
WATERMASS
3
Download from Www.Somanuals.com. All Manuals Search And Download.
REMARKS ON USAGE
The accuracy will not be affected by:
• - water temperature (sound velocity)
• salinity
Remarks on Usage
The DS-80 measures ship’s speed by
detecting the Doppler shift frequency of the
echo reflected by a watermass (water layer
containing plankton and other micro-
• pitch/roll ±10°
organisms) located within the measuring
area, which is usually about 2 m. In some
instances, however, no signal is returned
because of too few plankton in the sensing
depths. This phenomenon can occur in
particular areas in particular seasons. The
probable cause is the plankton are lying in
deep water because an ice-melted cold
water mass covers the sea surface. Similar
cases may also occur in a freshwater lake.
Under these circumstances the DS-80 will
not show the correct ship’s speed.
Beware of Transducer Location
The transducer may be damaged if it hits
the dry dock blocks. Take the following
measures to prevent damage to the
transducer.
1. Before delivering the ship, draw up a
suitable docking plan taking into
account the dimensions and location of
the transducer. Store the plans onboard
the ship.
2. Place the dry dock blocks according to
the plan.
Conditions Affecting the
Accuracy
3. Have a diver check the position
between the transducer and the blocks
before removing the water. Confirm that
the transducer will not touch the blocks.
(with ref to IMO A.824/3.3)
The Doppler speed log DS-80 is designed for
reliable and accurate performance through
FURUNO’s long experience and advanced
technology. It operates on the best choice of
system frequency and power output. As far as
the sonic energy is used, the performance
(accuracy) may be reduced or even lost
under:
• rough weather (may be sea state 6 or
severer)
• improper location of sensor, e.g., too close
to the propeller, thrusters, drain tubes, echo
sounder transducer
• depth under the keel if less than 3 m
4
Download from Www.Somanuals.com. All Manuals Search And Download.
1 OPERATION OF DISPLAY UNIT
1.1 Controls
Omnipad
Selects items, options
on menus.
ENT
DIM
Registers options on menus.
Opens/closes the menu.
MENU
DISP
Selects display; speed
plus distance or speed.
Adjusts panel illumination.
Adjusts LCD contrast.
*
Turns power on/off.
PWR
DS-80
1.2 Turning the Power On/Off
1.2.2 Power off
1.2.1 Power on
Press the [POWER] switch to turn the
power off.
Press the [POWER] switch to turn on the
equipment. The last-used display appears.
The example below shows the speed and
distance run.
Note: Keep the DS-80 energized
continuously unless it fails. Turning off the
DS-80 may cause an inconvenience in
associated equipment, such as a radar.
SPEED
STW
Speed
kt
10.0
DISTANCE
Distance
Run
12.50
nm
Note: STW means Speed Through Water. This
indication flashes when transducer temperature,
which can be monitored on the TEST display
(see page 16), is abnormal. This means speed
accuracy is less than stated in the
specifications.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
1.3 Adjusting Contrast, Panel
Dimmer
1.4 Selecting a Display
Press the [DISP] key to select display
desired. Each time the key is pressed the
display shows speed and distance run or
speed alone as below.
1.3.1 Contrast
1. Press the [*] key to open the contrast
adjustment dialog box.
Direction
: Fore
: Aft
CONTRAST (0~63)
41
SPEED
STW
EXIT: [ENT]
Speed
kt
10.0
DISTANCE
2. Press the Omnipad at or to adjust
the contrast. The setting range is 0 to 63
and the default setting is 48.
Distance
Run
12.50
nm
3. Press the [ENT] key.
[DISP] key
to switch
Note: The contrast is automatically set to
default (48) when the power is turned on.
SPEED
STW
1.3.2 Panel dimmer
1 0 . 0
1. Press the [DIM] key to show the dimmer
adjustment dialog box.
kt
DIMMER (1~8)
7
• Arrow indicates direction: indicates
fore; , aft.
EXIT: [ENT]
• The distance run indication shows the
total distance run in forward speed only.
2. Press the Omnipad at or to adjust
the dimmer. The setting range is 1 to 8
and the default setting is 4.
• The distance run is backed up when the
power is turned off.
3. Press the [ENT] key to conclude.
Note: Speed error may occur in rough seas
because of air bubbles, etc.
Note: The [DIM] key is inoperative when
When speed error occurs, the speed
indication freezes, and “KT” is highlighted
and blinks. If speed error continues more
than 30 seconds, the speed indication
changes to **.*.
dimmer is controlled externally.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Press the [MENU] key twice to close the
menu. (Some menus require only a
single pressing of the [MENU] key.)
1.5 Main Menu Operation
Functions of the DS-80 are selected
through the menu.
To enter numerical data
1. Press the [MENU] key to open the
menu.
Some menus require input of numeric data.
This is done with the Omnipad.
MENU
DISTANCE RUN DISPLAY
DEMO
SYSTEM MENU
SYSTEM MENU2
1. Select the digit or sign (+ or -) to change
with or on the Omnipad. (The
cursor shows the digit or sign selected.)
2. Enter a figure at each digit by hitting the
Omnipad at
or . The example
2. Press the Omnipad at
or to select
below shows the DISTANCE RUN
DISPLAY menu, where you may adjust
the distance run indication for SET.
a menu item (current selection is
highlighted) and press the [ENT] key.
For example, when DISTANCE RUN
DISPLAY is selected the following
display appears. Distance run is a form
of contact closure, 200 pulses/nm. To
select IEC 61162 sentence, see
paragraph 1.6.1.
DISTANCE RUN DISPLAY
DATA DISPLAY
CONTACT CLOSURE
RESET
SET
OFF
Cursor
000000.00nm
ENT SET
DISTANCE RUN DISPLAY
3. Press the [ENT] key to conclude.
DATA DISPLAY
CONTACT CLOSURE
RESET
SET
OFF
1.6 Distance Run Operation
0.00nm
ENT SET
The operator may adjust and reset the
distance run indication and select display
method.
3. Press the Omnipad at
or to select
the menu item desired and press the
[ENT] key. For example select RESET.
1.6.1 Selecting display method
DISTANCE RUN DISPLAY
The default setting provides for independent
display and adjustment of the distance run
indication on all displays (display unit,
Digital Indicator, distance indicator).
DATA DISPLAY
CONTACT CLOSURE
RESET
SET
OFF
OFF
ON
To show the same distance run indication
on all displays do the following:
4. Press the Omnipad at
or to select
1. Press the [MENU] key to open the
menu.
the menu option desired and press the
[ENT] key.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
The cursor circumscribes the leftmost
digit of the distance run figure.
MENU
DISTANCE RUN DISPLAY
DEMO
SYSTEM MENU
SYSTEM MENU2
DISTANCE RUN DISPLAY
DATA DISPLAY
CONTACT CLOSURE
RESET
SET
OFF
2. Press the Omnipad at
to select
Cursor
DISTANCE RUN DISPLAY and press
the [ENT] key.
000000.00nm
ENT SET
DISTANCE RUN DISPLAY
4. Press the Omnipad at or to select
the digit to change.
DATA DISPLAY
CONTACT CLOSURE
5. Press the Omnipad at
or to
RESET
OFF
SET
change value. The setting range is 0.00
nm to 999999.99 nm.
0.00nm
ENT SET
6. Press the [ENT] key followed by
pressing the [MENU] key twice to
conclude your selection and close the
menu.
3. Select DATA DISPLAY and press the
[ENT] key.
DISTANCE RUN DISPLAY
DATA DISPLAY
CONTACT CLOSURE
1.6.3 Resetting distance run to zero
R
IEC61162(VLW)
S
CONTACT CLOSURE
Distance run can be reset to zero when the
menu item DATA DISPLAY is selected to
CONTACT CLOSURE. It may also be reset
to zero only at the display unit when IEC
61162(VLW) is selected.
ENT SET
4. Press
to select IEC 61162(VLW)
and press the [ENT] key.
5. Press the [MENU] key twice to close the
menu.
1. Press the [MENU] key to open the
menu.
2. Press the Omnipad at
to select
1.6.2 Adjusting distance run
DISTANCE RUN DISPLAY and press
the [ENT] key.
Distance run can be changed when the
menu item DATA DISPLAY is selected to
CONTACT CLOSURE. It may also be
changed only at the display unit when IEC
61162(VLW) is selected. .
3. Select RESET and press the [ENT] key.
DISTANCE RUN DISPLAY
DATA DISPLAY
CONTACT CLOSURE
RESET
SET
OFF
1. Press the [MENU] key to open the
menu.
OFF
ON
2. Use
to select DISTANCE RUN
DISPLAY and press the [ENT] key.
4. Press the Omnipad at
to select ON.
3. Select SET and press the [ENT] key.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Press the [ENT] key to finish and press
the [MENU] key twice to close the
menu.
3. Select averaging time period desired
among 15, 30, 45 and 60 seconds.
4. Press the [ENT] key.
The distance run indication reads 0.00.
5. Press the [MENU] key twice to close the
menu.
1.7 System Setting
1.7.3 Speed offset (calibration)
The system setting provides the
fundamental parameters for intended
performance of the DS-80.
Calibration of any speed log is necessary
through the sea trials during the
commissioning tests. Fill in the calibration
sheet which is on page 25 of this manual.
Us the resultant data to calculate speed
offset and enter it as below. The setting
range is -25.0% to +25.0%.
1.7.1 Displaying the system menu
1. Press the [MENU] key to open the
menu.
2. Select SYSTEM MENU and press the
[ENT] key.
1. Open the SYSTEM MENU.
2. Select SPEED OFFSET and press the
[ENT] key.
SYSTEM MENU
SHIP SPEED AVG 15 SEC
SPEED OFFSET
TRACK DEPTH
XDR OFFSET
+0.0%
2.0 m
+00˚
SYSTEM MENU
SHIP SPEED AVG 30 SEC
SPEED OFFSET
TRACK DEPTH
XDR OFFSET
+0.0%
2.0 m
+00˚
SPD DATA SELECT
DOPPLER
ENT: SET
SPD DATA SELECT
DOPPLER
ENT: SET
1.7.2 Ship speed average
Wind and currents affect ship’s speed, and
speed data is averaged over the time period
set on this menu. Increase the speed
averaging period if the speed reading is
unstable.
3. Select the digit to change with or
and change the value with
the Omnipad.
or on
4. Press the [ENT] key.
5. Press the [MENU] key twice to close the
menu.
1. Open the SYSTEM MENU.
2. Select SHIP SPEED AVG and press the
[ENT] key.
1.7.4 Tracking depth
15 SEC
30 SEC
45 SEC
60 SEC
Doppler shift measuring depth in the DS-80
is 2 m at default. If the speed readout is
unstable due to air bubbles near the ship’s
hull, increase or decrease the track depth to
stabilize the readout. The setting range is
1.0 m to 9.9 m.
1. Open the SYSTEM MENU.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
1.7.6 Speed data selection
SYSTEM MENU
SHIP SPEED AVG 30 SEC
When the DS-80 fails to work as an SDME,
the display unit can be used as a monitor
display tool for a GPS speed or other
equipment measuring the ship’s speed.
SPEED OFFSET
TRACK DEPTH
XDR OFFSET
+0.0%
2.0 m
+00˚
SPD DATA SELECT
DOPPLER
ENT: SET
1. Open the SYSTEM MENU.
2. Select TRACK DEPTH and press the
[ENT] key.
2. Select SPD DATA SELECT and press
the [ENT] key.
SYSTEM MENU
GPS
DOPPLER
AUTO
SHIP SPEED AVG 30 SEC
SPEED OFFSET
TRACK DEPTH
XDR OFFSET
+0.0%
2.0 m
+00˚
SPD DATA SELECT
3. Select the option GPS and press the
[ENT] key.
DOPPLER
ENT: SET
4. Press the [MENU] key twice to close the
menu.
3. Select the digit to change or and
change the value with
Omnipad.
or on the
See the illustration below for speed display
information. If the speed displayed is
unstable perform the check described in
paragraph 3.2.
4. Press the [ENT] key.
5. Press the [MENU] key twice to close the
menu.
GPS-measured
speed
1.7.5 Transducer offset
SPEED
GPS
SPEED
STW
10.0 kt
kt
10.0
DISTANCE
DISTANCE
Sets the deviation angle of the transducer’s
orientation with reference to the ship’s
longitudinal axis. This is done at installation;
no user adjustment is necessary.
12.50
12.50
nm
nm
GPS speed
Doppler speed
"AUTO" position indicates a Doppler speed
(SDME) but if the DS-80 fails, a GPS speed
will be indicated.
Note 1: If the log speed fails, the display
unit reads a GPS speed, but speed data will
not be output to other equipment.
Note 2: Doppler speed is used to calculate
speed when both DOPPLER and GPS are
abnormal in AUTO.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Select the digit to change with or .
1.7.7 System menu 2
5. Use
is
or to set. (The setting range
The System Menu 2 contains the diagnostic
test and selection of dimmer control and
display language.
-10.0 to +40.0 kt, and the default setting
is +10.0 kt.)
1. Press the [MENU] key to open the
menu.
6. Press the [ENT] key.
7. Press the [ENT] key to open the DATA
DISPLAY menu.
2. Select SYSTEM MENU 2 and press the
[ENT] key.
DEMO
SPEED
SYSTEM MENU2
+10.0 kt
DATA DISPLAY
OFF
ON
OFF
TEST
DIMMER
INTERNAL
/LANG. ENGLISH
ENT: SET
ENT: SET
8. Press
to select ON and press the
[ENT] key.
TEST: Checks the equipment for proper
9. Press the [MENU] key twice to close the
menu.
operation. For further details see Chapter 3.
DIMMER: See paragraph 1.3.2.
The indication “DEMO” appears at the top
right-hand corner when the demo mode is
on. To turn off the demonstration display,
show the DEMO menu and set SPD to OFF.
LANG.: Selects the language to use in
menus, English or Japanese.
1.8 Demonstration Mode
SPEED
DEMO
Demonstration
mode "ON"
The demonstration mode outputs the
Doppler speed signal to external equipment.
This checks if the signal is being correctly
output. )
10.0 kt
DISTANCE
1. Press the [MENU] key to open the
menu.
2. Select DEMO and press the [ENT] key.
DEMO
SPEED
+10.0 kt
DATA DISPLAY
OFF
ENT: SET
3. Select SPEED and press the [ENT] key.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
2 OPERATION OF OPTIONAL
EQUIPMENT
The Digital Indicator DS-830 and Distance
Indicator DS-840 have the same controls as
the display unit. This chapter explains the
features which are not shared with the
display unit.
SPEED
STW
Speed
10.0kt
12.50
DISTANCE
Distance
Run
DISTANCE INDICATOR nm
[DISP] key
to switch
2.1 Digital Indicator DS-830,
Distance Indicator DS-840
DISTANCE
2.1.1 Selecting a display
Press the [DISP] key to select the display
mode. Each time the key is pressed the
display shows speed plus distance run or
speed alone as below.
1 2 . 5 0
DISTANCE INDICATOR
nm
Distance Indicator DS-840
SPEED
STW
Speed
kt
10.0
2.1.2 Menu operation
DISTANCE
Distance
Run
1. Press the [MENU] key to show the
display below.
12.50
nm
SPEED INDICATOR
MENU
[DISP] key
to switch
DISTANCE RUN DISPLAY
SYSTEM MENU2
SPEED
STW
1 0 . 0
SPEED INDICATOR
kt
2. For details refer to the following:
DISTANCE RUN DISPLAY: See paragraph
Digital Indicator DS-830
1.6.
SYSTEM MENU 2: See 1.7.7 System Menu
2.
2.1.3 Adjusting dimmer and
contrast
See paragraph 1.3.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
ANALOG DISPLAY UNIT
CORRECTION DIAGRAM AT EXTREME TEMPERATURES
Doppler Speed Log DS-80
CORRECTION FACTOR FOR ANALOG DISPLAY MF-22A-1
Example:
If the analog speedometer reads 14.2 kt at a temperature of –15°C, the correct speed
through the water is 15 kt. Failure of correction in low temperature can result in a maximum
error of –0.8 kt or 5.3% for 14.2 kt readout. IMO limit of ±2% is exceeded over 10.0 – 30.0 kt
reading but correction by this graph brings a correct measurement.
At +55°C, an error of +0.0 kt (+2.7%) occurs at a speed of 30 kt; no other point IMO limit of
±2% is exceeded.
When the digital display and analog display readouts are different, take precedence of the
digital readout. At temperatures 0°C to 50°C, the speedometer never exceeds the IMO
limits.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
3 MAINTENANCE, TROUBLESHOOTING
WARNING
CAUTION
ELECTRICAL SHOCK HAZARD
Do not paint the transducer.
Do not open the equipment.
Painting will affect performance.
Only qualified personnel
should work inside the
equipment.
3.1.3 Fuse replacement
Fuses in the units of the system protect the
electrical circuitry from burning by
3.1 Maintenance
3.1.1 Preventive maintenance
overcurrent. If the equipment cannot be
energized check the fuse in the power
cable connected to the display unit. Locate
the cause before replacing the fuse.
Check the following points regularly to
maintain performance.
Check that the connectors on all units of
the system are firmly fastened and free of
rust. Clean if soiled or corroded.
•
Rating,
Qty
Type,
Code No.
Unit
Location
FGMB 1A Fuse
125 VAC, holder in
000-114-8 power
Check that all ground wires are tightly
fastened.
•
•
Display
Unit
1A,
2 pcs.
05
cable
Dust and dirt on the display unit including
the screen may be removed with a soft
cloth. Do not use chemical cleaners to
clean the display unit; they can remove
paint and markings.
FGBO 3A Inside
250 VAC
000-549-
021
Distribution 3A,
Box
unit
2 pcs.
FGBO 1A
250 VAC,
000-549-
019
Transceiver 1A,
Unit
2 pcs.
3.1.2 Transducer maintenance
Marine life (barnacles, etc.) adhering to the
transducer face will reduce sensitivity.
Periodically remove any marine life from
the transducer face with fine sandpaper or
a piece of wood.
CAUTION
Use the proper fuse.
Use of a wrong fuse can cause fire or
equipment damage and void the warranty.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 Troubleshooting
This section provides troubleshooting procedures. Advanced level troubleshooting should
be done by referring to the Service Manual (optional supply).
Problem
General
Probable cause
Remedy
Cannot turn on the
power.
Loosened power cable Fasten the power cable.
Blown fuse
Replace the fuse.
Power is on but
nothing appears on
the screen.
Contrast too low.
Press the [*] key several times.
Doppler speed indication
Ship’s speed cannot be calculated
because of air bubbles, etc. (Speed error :
30 seconds)
Last correct speed is displayed
(display freezes).
STW
SPEED
kt
10.0
12.50
DISTANCE
Reverse video and blinking
nm
SPEED
STW
• Problem with the transducer or air
Speed shown as "**.*".
**. *
bubbles.
kt
DISTANCE
• Speed error continues more than 30
12.50
nm
seconds.
SPEED
STW
• Temperature sensor is abnormal.
STW
flashing
kt
10.0
DISTANCE
12.50
nm
GPS speed indication
SPEED
GPS
GPS data error.
Speed indication shown as "**.*".
**.*
kt
DISTANCE
12.50
nm
SPEED
•
•
No GPS data for 30 seconds.
GPS receiver disconnected.
----
--k-t
"GPS" is replaced with "----".
DISTANCE
12.50
nm
If any abnormal speed indication continues
contact your dealer for advice.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
control is operated within five seconds,
the equipment automatically begins
3.3 Diagnostics, Checking
Program Number
checking the LCD.
The diagnostic facility checks the ROM,
RAM, SIO and displays program ID.
Transducer temperature
Name of control operated
appears here.
1. Press the [MENU] key to open the
menu.
TEST
ROM
RAM
SIO
PUSH KEY
(STOP: PWR OFF)
6550100003I
: OK 12.3CX
: OK
: OK
X appears when
temperature
sensor is
2. Select SYSTEM MENU2 and press the
[ENT] key.
abnormal
6550110003J
6550120003K
No. of times test
consecutively
executed.
CNT: 006
SYSTEM MENU2
TEST
6550100003I = Display Unit DS-800
6550110003J = Distribution Box DS-801
6550120003K = Transceiver Unit DS-810
DIMMER
INTERNAL
/LANG. ENGLISH
Control operated and indication
Control
Indication
UP
3. Press the [ENT] key. The following
display appears.
DOWN
LEFT
RIGHT
MENU
ENT
DISP
DIM
*
TEST START ?
(STOP: PWR OFF)
MENU
ENT
DISP
DIM
*
ARE YOU SURE ?
YES
NO
4. Press the [ENT] key to start the test. In
a few moments the display should
changes as shown at the top of the
adjacent column.
5. The equipment automatically checks
the LCD, displaying the following in
order.
<LCD CHECK>
The ROM, RAM and SIO (if special
connector is used) are checked for
proper operation and the results shown
as OK or NG (No Good). For NG,
contact your dealer for advice.
ALL ON 2 SEC.
ALL OFF 3 SEC.
The program number also appears
here.
“PUSH KEY” is highlighted, prompting
you to check the controls. Operate any
control (except the [POWER] switch)
within five seconds. The name of the
activated control appears on screen if it
is operating normally. Note that if no
6. The test repeats itself. To stop the test,
turn the power switch off and on again.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
4 DIGITAL INTERFACE (IEC 61162-1
Edition 2)
4.1 I/O Sentences
Input sentences of IEC61162_RX port
GGA, VTG
Output sentences of IEC61162_TX1, IEC61162_TX2 ports
VBW, VLW (Talker: VD)
Transmission interval
3 s for VBW; 1 s for VLW
Data transmission
Data is transmitted in serial asynchronous form in accordance with the standard referenced
in 2.1 of IEC 61162-1. The first bit is a start bit and is followed by data bits,
least-significant-bit as illustrated below.
The following parameters are used:
Baud rate: 4800
Data bits: 8 (D7 = 0), parity none
Stop bits: 1
D0 D1 D2 D3 D4 D5 D6 D7
Stop
bit
Start
bit
Data bits
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Schematic diagrams
IEC61162 RX port
DS-801
65P6010
.
.
.
.
TB3
F2047A-20P-B
JP6
PC400
U42
ERJ_6GEY0R00V
6
IEC61162_RX_A
IEC61162_RX_B
11
12
.
<11<
<12<
R121 22Ω
1
2
1
3
R122 120Ω
R123 120 Ω
R124 22Ω
4
.
CR17 1SS181
5
JP7
ERJ_6GEY0R00V
Load requirements as listener
Isolation: Optocoupler
Input Impedance: 44 ohms
Max. Voltage: ±2.6V
Threshold: 4 mA
IEC61162 TX1 port
Output drive capability
Max. 20 mA
18
Download from Www.Somanuals.com. All Manuals Search And Download.
IEC61162 TX2 port
DS-801
65P6010
Vcc
1
.
.
.
.
TB3
F2047A-20P-B
U43
R136
47
SN75ALS191PS
8
7
2
<7<
<8<
IEC61162_TX2_A
IEC61162_TX2_B
9
10
.
R135
47
.
.
.
4
Output drive capability
Max. 20 mA
19
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2 Sentence Description
GGA - Global positioning system (GPS) fix data
Time, position and fix related data for a GPS receiver.
Note: Item Only GPS quality indicator and antenna altitude above/below are used.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
VTG - Course over ground and ground speed
The actual course and speed relative to the ground.
$--VTG,x.x,T,x.x,M,x.x,N,x.x,K,a*hh<CR><LF>
| | | | | | | | | |
| | | | | | | | | +------- 6
| | | | | | | | +--------- 5
| | | | | | +--+----------- 4
| | | | +--+----------------- 3
| | +--+----------------------- 2
+--+----------------------------- 1
1. Course over ground, degrees true
2. Course over ground, degrees magnetic
3. Speed over ground, knots
4. Speed over ground, km/h
5. Mode indicator(see note)
6. Checksum
NOTE Positioning system Mode indicator:
A = Autonomous
D = Differential
S = Simulator
N = Data not valid
The positioning system Mode indicator field shall not be a null field.
Note: Speed, course degrees magnetic and course degrees true not used.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
VBW - Dual ground/water speed
Water-referenced and ground-referenced speed data.
$--VBW,x.x,x.x,A,x.x,x.x,A,x.x,A,x.x,A*hh<CR><LF>
|
|
|
|
|
|
|
|
|
|
| |
| |
| |
| |
| |
| |
| |
| |
|
|
|
|
|
|
|
|
| | | |
| | | |
|
|
| |
| +--- 11
| | | | | +----- 10
| | | | +-------- 9
| | | +----------- 8
| | +-------------- 7
| +----------------- 6
+-------------------- 5
| | +------------------------ 4
| +--------------------------- 3
| +------------------------------ 2
+---------------------------------- 1
1. Longitudial water speed, knots
2. Transverse water speed, knots
3. Status: water speed, A=data valid V=data invalid
4. Longitudial ground speed, knots
5. Transverse ground speed, knots
6. Status: ground speed, A=data valid V=data invalid
7. Stern transverse water speed, knots
8. Status: stern water speed, A=data valid V=data invalid
9. Stern transverse ground speed, knots
10. Status: stern ground speed, A=data valid V=data invalid
11. Checksum
Notes
1. Longitudinal speed: “-” astern.
* Not used.
VLW - Distance travelled through the water
The distance travelled, relative to the water.
$--VLW,x.x,N,x.x,N*hh<CR><LF>
|
|
|
|
|
| | |
| | +--------- 3
| +--+----------- 2
+--+----------------- 1
1. Total cumulative distance, nautical miles
2. Distance since reset, nautical miles
3. Checksum
22
Download from Www.Somanuals.com. All Manuals Search And Download.
5 PARTS LOCATION AND PARTS LIST
Parts Location
Display unit DS-800
U10 (ROM)
ICP Board 65P6000, parts side
Distribution box DS-801
From right TB1, TB2, TB3
TB101
POWER
switch
JPW Board
Distribution Box DS-801, inside view
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Transceiver unit DS-810
TB101
TB1
POWER
Switch
KCP Board
Transceiver Unit DS-810, inside view
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts List
This equipment contains complex modules in which fault diagnosis and repair down to
component level are not practicable (IMO A.694(17)/8.3.1). Only some discrete components
are used. FURUNO ELECTRIC CO., LTD. believes identifying these components is of no
use for shipborne maintenance; therefore, they are not listed in this manual. Major modules
can be located on parts location photos on the preceding page.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
Unit
DS-80
DISPLAY UNIT DS-800
ELECTRICAL PARTS LIST
Ref.Dwg. C3441-K01-C
2000-01 Block.No.
SYMBOL TYPE
CODE No.
REMARKS
SHIPPABLE
ASSEMBLY
PRINTED CIRCUIT BOARD
65P6000, ICP
000-142-649
X
CABLE w/CONNECTOR
MJ-A7SPF-005-020
MJ-A6SPF-003-020
MJ-PH 6P
000-139-384
000-142-658
000-142-659
000-142-660
20S0251
65S1231
65S1227
65S1228
MJ-PH 7P
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
Unit
DS-80
TRANSCEIVER DS-810
ELECTRICAL PARTS LIST
Ref.Dwg. C7247-K02-A
2000-01 Block.No.
SYMBOL TYPE
CODE No.
REMARKS
SHIPPABLE
ASSEMBLY
PRINTED CIRCUIT BOARD
65P6020,KCP
002-889-570
002-889-530
000-474-214
000-136-287
000-142-647
000-137-321
000-132-968
X
X
POWER SUPPLY ASSEMBLY
DS-810
SWITCH
S-331
S1
VARISTOR
ERZV-20D471
CR1
T1
TRANSFORMER
65S1218
TERMINAL BOARD
F1003-20A-5725-6P
TB101
XF1
NOISE FILTER
ZGB2202-01U
CABLE w/CONNECTOR
66-045(2P)
65-046(6P)
002-889-550
002-889-560
VH CONNECTOR
VH CONNECTOR
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
Unit
DS-80
DISTRIBUTOR DS-801
ELECTRICAL PARTS LIST
Ref.Dwg. C7247-K03-A
2000-01 Block No.
SYMBOL TYPE
CODE No.
REMARKS
SHIPPABLE
ASSEMBLY
PRINTED CIRCUIT BOARD
65P6010,JPW
002-889-490
002-889-470
ASSEMBLY
DS-801
POWER SUPPLY
POWER SUPPLY ASSEMBLY
DS-801-100
DS-801-110
DS-801-115
DS-801-200
002-889-410
002-889-420
002-889-430
002-889-440
002-889-450
002-889-460
DS-801-220
DS-801-230
SWITCH
S1
S-331
000-474-214
000-136-287
000-142-631
000-138-909
000-142-633
000-120-155
VARISTOR
ERZV-20D471
CR1
TB101
F1
TERMINAL BOARD
F1003-20A-2P
FUSE HOLDER
FH-001AF
POWER SUPPLY
FAW-24-2R1
PD1
XF1
NOISE FILTER
ZAC2210-11
28
Download from Www.Somanuals.com. All Manuals Search And Download.
CALIBRATION SHEET
29
Download from Www.Somanuals.com. All Manuals Search And Download.
MENU OVERVIEW
Default settings in bold italic.
[MENU] key
DISTANCE RUN DISPLAY
DATA DISPLAY (CONTACT CLOSURE, IEC 61162-1(VLW))
RESET (ON, OFF)
SET (0.0 nm-999999.99 nm, 0.00 nm)
DEMO
SPEED (-10.0 to +40.0 kt, +10.0 kt)
DATA DISPLAY (OFF, ON)
SHIP SPD AVG (15, 30, 45, 60 SEC)
SPEED OFFSET (-25.0% to +25.0%, 0%)
TRACK DEPTH (1.0 m to 9.9 m, 2 m)
XDR OFFSET (-40˚ to +40˚, 0˚)
SYSTEM MENU
SPD DATA SELECT (GPS, DOPPLER, AUTO)
TEST (Check of ROM, RAM, LCD, Key Panel)
DIMMER (INTERNAL, EXTERNAL)
LANG. (ENGLISH, JAPANESE)
SYSTEM MENU2
30
Download from Www.Somanuals.com. All Manuals Search And Download.
INDEX
C
P
Contrast.......................................................... 6
Control description ......................................... 5
Parts list ........................................................20
Parts location ................................................18
POWER switch ...............................................5
D
S
Demonstration mode...................................... 9
Diagnostics................................................... 14
Digital indicator............................................. 12
Digital interface............................................. 16
Digitial display .............................................. 12
DIM key .......................................................... 6
Dimmer........................................................... 6
Distance run
Ship's speed
averaging time.............................................9
offset..........................................................10
source........................................................11
System configuration ......................................2
System menu..................................................9
System menu2..............................................11
adjusting ..................................................... 9
display method............................................ 8
resetting to zero.......................................... 8
T
Transducer
maintenance..............................................13
position offset............................................10
Troubleshooting ............................................14
F
Fuse replacement......................................... 13
M
U
Maintenance................................................. 13
MENU key ...................................................... 7
Menu operation .............................................. 7
Menu tree ..................................................... 24
UNIT key.........................................................7
W
Water tracking depth.....................................10
Index-1
Download from Www.Somanuals.com. All Manuals Search And Download.