Fujitsu Server BX400 S1 User Manual

Operating Manual - English  
PRIMERGY BX400 S1  
Blade Server Version  
System Unit Operating Manual  
May 2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before reading this manual  
For your safety  
This manual contains important information for safely and correctly using this  
product.  
Carefully read the manual before using this product. Pay particular attention to  
the accompanying manual "Safety Notes and Regulations" and ensure these  
safety notes are understood before using the product. Keep this manual and the  
manual "Safety Notes and Regulations" in a safe place for easy reference while  
using this product.  
Radio interference  
This product is a "Class A" ITE (Information Technology Equipment). In a  
domestic environment this product may cause radio interference, in which case  
the user may be required to take appropriate measures.  
VCCI-A  
Aluminum electrolytic capacitors  
The aluminum electrolytic capacitors used in the product's printed circuit board  
assemblies and in the mouse and keyboard are limited-life components. Use of  
these components beyond their operating life may result in electrolyte leakage  
or depletion, potentially causing emission of foul odor or smoke.  
As a guideline, in a normal office environment (25°C) operating life is not  
expected to be reached within the maintenance support period (5 years).  
However, operating life may be reached more quickly if, for example, the  
product is used in a hot environment. The customer shall bear the cost of  
replacing replaceable components which have exceeded their operating life.  
Note that these are only guidelines, and do not constitute a guarantee of  
trouble-free operation during the maintenance support period.  
High safety use  
This product has been designed and manufactured for general uses such as  
general office use, personal use, domestic use and normal industrial use. It has  
not been designed or manufactured for uses which demand an extremely high  
level of safety and carry a direct and serious risk to life or body if such safety  
cannot be ensured.  
BX400 S1  
Operating Manual  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
These uses include control of nuclear reactions in nuclear power plants,  
automatic airplane flight control, air traffic control, traffic control in mass  
transport systems, medical devices for life support, and missile guidance  
control in weapons systems (hereafter, "high safety use"). Customers should  
not use this product for high safety use unless measures are in place for  
ensuring the level of safety demanded of such use. Please consult the sales  
staff of Fujitsu if intending to use this product for high safety use.  
Measures against momentary voltage drop  
This product may be affected by a momentary voltage drop in the power supply  
caused by lightning. To prevent a momentary voltage drop, use of an AC  
uninterruptible power supply is recommended.  
(This notice follows the guidelines of Voltage Dip Immunity of Personal  
Computer issued by JEITA, the Japan Electronics and Information Technology  
Industries Association.)  
Technology controlled by the Foreign Exchange and Foreign Trade  
Control Law of Japan  
Documents produced by Fujitsu may contain technology controlled by the  
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which  
contain such technology should not be exported from Japan or transferred to  
non-residents of Japan without first obtaining authorization in accordance with  
the above law.  
Harmonic Current Standards  
This product conforms to harmonic current standard JIS C 61000-3-2.  
Only for the Japanese market:  
About SATA hard disk drives  
The SATA version of this server supports hard disk drives with SATA / BC-SATA  
storage interfaces. Please note that the usage and operation conditions differ  
depending on the type of hard disk drive used.  
Please refer to the following internet address for further information on the  
usage and operation conditions of each available type of hard disk drive:  
http://primeserver.fujitsu.com/primergy/harddisk/  
4
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Only for the Japanese market:  
I
Although described in this manual, some sections do not apply to the  
Japanese market. These options and routines include:  
CSS (Customer Self Service)  
BX400 S1  
Operating Manual  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Contents  
1
1.1  
1.2  
1.3  
1.4  
1.5  
Concept and target groups for this manual . . . . . . . . . 11  
2
Installation steps, overview . . . . . . . . . . . . . . . . . . 23  
3
3.1  
3.2  
3.3  
3.4  
3.5  
4
4.1  
4.2  
4.3  
Installation procedure . . . . . . . . . . . . . . . . . . . . . 38  
Unpacking the system unit . . . . . . . . . . . . . . . . . . 38  
Setting up the floorstand model . . . . . . . . . . . . . . . . 39  
4.4  
Installing/removing the rack model . . . . . . . . . . . . . . 40  
Rack system requirements . . . . . . . . . . . . . . . . . . . 40  
Installation in the rack . . . . . . . . . . . . . . . . . . . . . . 43  
Installing/removing the system unit . . . . . . . . . . . . . . . 46  
4.4.1  
4.4.2  
4.4.3  
4.5  
Connecting devices to the system unit . . . . . . . . . . . . 49  
4.5.1  
Cable routing . . . . . . . . . . . . . . . . . . . . . . . . . . 51  
4.6  
Connecting the system unit to the mains . . . . . . . . . . 51  
BX400 S1  
Operating Manual  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
4.6.1  
4.7  
5
Installation and operation . . . . . . . . . . . . . . . . . . . . 55  
5.1  
5.1.1  
Front of system . . . . . . . . . . . . . . . . . . . . . . . . . . 55  
LEDs on the control panel . . . . . . . . . . . . . . . . . . . 58  
Back of system . . . . . . . . . . . . . . . . . . . . . . . . . . 61  
Control and display elements on the management blade . . . 61  
Indicator on the hot-plug power supply units . . . . . . . . . 64  
5.1.1.1  
5.1.1.2  
5.1.1.3  
5.1.2  
5.1.2.1  
5.1.2.2  
5.1.2.3  
5.2  
5.3  
5.4  
6
7
Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 77  
7.1  
7.2  
7.3  
8
Hot-plug components . . . . . . . . . . . . . . . . . . . . . . 81  
Server blades and storage blades . . . . . . . . . . . . . . . 82  
8.1  
8.2  
Connection blades . . . . . . . . . . . . . . . . . . . . . . . 88  
Connection Blade GbE Switch/IBP 36/12 (SB11A) . . . . . . . . 89  
Connection Blade GbE Switch/IBP 36/8+2 (SB11) . . . . . . . . 91  
Connection blade stacking . . . . . . . . . . . . . . . . . . 94  
Connection Blade GbE Switch/IBP 18/6 (SB6) . . . . . . . . . . 95  
Connection Blade 10 GbE Switch/IBP 18/8 . . . . . . . . . . . . 97  
8.2.1  
8.2.2  
8.2.2.1  
8.2.3  
8.2.4  
8
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Contents  
8.2.5  
8.2.6  
8.2.7  
8.2.8  
8.2.9  
8.2.10  
8.2.11  
Connection Blade Ethernet Pass Thru 10Gb 18/18 . . . . . . . 99  
Connection Blade 8Gb FC Pass Thru 18/18 . . . . . . . . . . 104  
Fitting rules for connection blades . . . . . . . . . . . . . . . . 108  
Port assignment of the connection blades . . . . . . . . . . . . 110  
Installing a connection blade . . . . . . . . . . . . . . . . . . 112  
8.3  
Management blades . . . . . . . . . . . . . . . . . . . . . . 118  
8.4  
Hot-plug power supply units . . . . . . . . . . . . . . . . . 119  
8.4.1  
Replacing the power supply unit . . . . . . . . . . . . . . . . . 121  
8.5  
Hot-plug fan modules . . . . . . . . . . . . . . . . . . . . . 123  
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125  
BX400 S1  
Operating Manual  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
10  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
1
Introduction  
The PRIMERGY BX400 S1 blade server is a highly compact, energy-saving  
and scalable server system for installation in a 19-inch rack or as a floorstand  
model. The BX400 S1 system unit offers 8 slots for a mixture of server blades  
and storage blades (therein a maximum of 4 single-slot storage-blades  
respectively 2 double-slot JBOD blades).  
With its advanced infrastructure modules, the BX400 S1 system unit offers the  
server blades a high level of connectivity and availability. These include hot-plug  
connection blades, redundant management blades and power supply units, the  
server management of the PRIMERGY ServerView suite, Prefailure Detection  
and Analyzing (PDA), and Automatic Server Reconfiguration and Restart  
(ASR&R).  
Security functions in the BIOS-setup of the server blades and on the system  
boards protect the data on the blade server from manipulation. Additional  
security is provided by the lockable rack door.  
The BX400 S1 system unit occupies 6 height units (HU) in the rack.  
1.1  
Concept and target groups for this manual  
This operating manual describes how to install, set up and operate your server.  
This operating manual is intended for those responsible for installing the  
hardware and ensuring that the system runs smoothly. It contains all the  
information you need to put your PRIMERGY BX400 S1 system unit into  
operation.  
To understand the various expansion options, you will need to be familiar with  
the fields of hardware and data transmission and you will require a basic  
knowledge of the underlying operating system.  
BX400 S1  
Operating Manual  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Introduction  
1.2  
Documentation overview  
More information on your PRIMERGY BX400 S1 system unit can be found in  
the following documents:  
"Quick Start Hardware - PRIMERGY BX400 S1" leaflet  
"はじめにお読みくださ-PRIMERGY BX400 S1" for the Japanese market  
(only included as a printed copy)  
"Safety Notes and Regulations" manual  
" 安全上のご注意 " for the Japanese market  
"Warranty" manual  
" 保証書 " for the Japanese market  
"ServerView Suite Local Service Concept - LSC" manual  
"Returning used devices" manual and "Service Desk" leaflet  
" サポート&サービス " for the Japanese market  
"PRIMERGY BX400 S1 System Unit Operating Manual"  
"PRIMERGY BX400 S1 System Unit Options Guide"  
I
PRIMERGY manuals are available in PDF format on the  
ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the  
ServerView Suite supplied with every server.  
relevant current versions using the order number U15000-C289 (the  
order number for the Japanese market: please refer to the configurator  
of the server http://primeserver.fujitsu.com/primergy/system/).  
from the Internet. The overview page showing the online documentation  
available on the Internet can be found using the URL (for EMEA market):  
http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can  
be accessed using the Industry standard servers navigation option.  
http://primeserver.fujitsu.com/primergy/manual/.  
Further sources of information  
Further information is provided:  
The Deployment Manager manual (only relevant for cloning server blades)  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
12  
   
Introduction  
Documentation on the server blades and storage blades  
The manual "PRIMERGY BX400 Blade Server Systems ServerView  
Management Blade S1 User Interface Description"  
1.3  
Performance features  
Customer Self Service (CSS)  
The Fujitsu Technology Solutions Customer Self Service (CSS) concept  
enables you to identify and replace the affected component yourself in the case  
of certain error scenarios.  
In the CSS concept, you can replace the following components yourself in the  
event of an error:  
Hot-plug hard disk drives  
Hot-plug power supply units  
Memory modules  
System fan  
Expansion cards  
For information on replacing these components, see chapter "Hot-plug  
components" on page 81.  
CSS indicators on the control panel and on the back of the PRIMERGY server  
provide you with information if a CSS event arises (for more information on the  
behavior of these indicators, see chapter "Installation and operation" on  
page 55 and the "ServerView Suite Local Service Concept - LSC" manual on  
the ServerView Suite DVD 2).  
Your system unit can fitted with a ServerView Local Service Display for Blade,  
which enables you to identify the type of component affected by the error  
directly on the server (for more information, see the "PRIMERGY  
ServerView Suite Local Service Concept - LSC" manual on the PRIMERGY  
ServerView Suite DVD 2).  
In addition, CSS errors are displayed in the ServerView Operations Manager -  
the server management software from Fujitsu Technology Solutions.  
BX400 S1  
Operating Manual  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Introduction  
In the event of errors, the ServerView Operations Manager refers you directly  
to the affected component and its order information in the Illustrated Spares  
catalog of the server in question. (This feature is not available for the Japanese  
market.)  
Server performance  
The system unit has 8 slots for server blades. Four server blade slots can be  
fitted with storage blades (or six slots with JBODs) which provide additional  
storage capacity for the neighboring server blades. For information on installing  
and removing server blades and storage blades, see section "Server blades  
and storage blades" on page 82. For further information on the server blades  
and storage blades, see the relevant operating manuals.  
Connection blades  
The PRIMERGY BX400 S1 system unit has four slots for connection blades on  
the back. These provide the installed server blades with connections to the  
Ethernet LAN as well as to SAN environments and Infiniband environments.  
The following connection blade types are available:  
Ethernet connection blades  
Connection Blade GbE Switch/IBP 36/12 (SB11A)  
36 internal 1-Gbit ports to the server blades  
8 external 1-Gbit ports through RJ45 connections  
4 external 1-Gbit ports through SFP modules  
I
This connection blade can be used in all connection blade slots.  
Connection Blade GbE Switch/IBP 36/8+2 (SB11)  
36 internal 1-Gbit ports to the server blades  
8 external 1-Gbit ports through RJ45 connections  
2 external 10-Gbit ports through SFP+ modules  
1 internal stacking port to the midplane of the BX400 S1 system unit  
1 external stacking port through a CX4 connection  
The stacking ports allow up to 4 SB11 connection blades to be  
switched together to form a so-called stack, see "Connection blade  
stacking" on page 94.  
I
This connection blade can be used in connection blade slots.  
14  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Introduction  
Connection Blade 1GbE Switch/IBP 18/6 (SB 6)  
18 internal 1-Gbit ports to the server blades  
6 external 1-Gbit ports through SFP+ modules or active twinax  
cables (copper)  
I
This connection blade can be used in all connection blade slots.  
Connection Blade 10 GbE Switch/IBP 18/8  
18 internal 10-Gbit ports to the server blades  
8 external 10-Gbit ports through SFP+ modules or active twinax  
cables (copper)  
I
This connection blade can be used in all connection blade slots.  
10 GbE connection blades in slots CB2 (fabric 2) and CB3/4  
(fabric 3) only support server blades that are fitted with a 10 Gbit  
Ethernet mezzanine card (see also section "Fitting rules for  
connection blades" on page 108).  
Connection Blade Ethernet Pass Thru 10Gb 18/18  
18 internal 1/10-Gbit ports to the server blades  
18 external 1/10-Gbit ports through SFP/SFP+ modules  
I
This connection blade can be used in all connection blade slots.  
If the connection blade is installed in one of the slots CB 1 or CB  
2, 16 ports are available. If the connection blade is installed in one  
of the slots CB 3 or CB 4, 8 ports are available (see also "Port  
assignment" on page 101).  
Fiber Channel connection blades  
Connection Blade 8Gb FC Switch 18/8  
18 internal 8-Gbit ports to the server blades  
8 external ports through 8-Gb SFP+ modules or 4-Gb SFP modules  
This connection blade is available in three license variants:  
Brocade 5450 with 14-port license  
Brocade 5450 with 26-port license (applies only to EMEA market)  
Brocade 5450 with 26 port license and performance bundle (applies  
only to EMEA market)  
BX400 S1  
Operating Manual  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Connection Blade 8Gb FC Pass Thru18/18  
18 internal 8-Gbit ports to the server blades  
I 18 external ports through 8-Gb SFP+ modules or 4-Gb SFP modules  
Fibre Channel connection blades can only be installed in slots CB3/4  
(fabric 3)and only support server blades that are fitted with a Fibre  
Channel mezzanine card.  
Infiniband connection blade  
Connection Blade Infiniband Switch 40 Gb 18/18  
18 internal 40-Gbit Infiniband ports to the server blades  
I 18 external 40-Gbit Infiniband connections through QSFP modules  
Infiniband connection blades can only be used in the slots CB 3/4,  
see figure "Connection blade slots" on page 108. They only support  
server blades that are fitted with an Infiniband mezzanine card.  
The connection blades support hot-swapping. By installing two connection  
blades in two adjacent slots (not possible with Infiniband connection blades),  
you can provide redundant network connections for the server blades (for  
details, see section "Connection blades" on page 88).  
Management blade  
The system unit has slots for two redundant, hot-swap management blades with  
an integrated management solution for complete remote administration of the  
system. The base configuration of the system unit contains one management  
blade (for details, see section "Management blades" on page 118).  
Power supply  
The system unit has four installation bays for hot-plug power supply units which  
automatically set themselves to a voltage in the range of 100 - 240 V. The base  
configuration includes one power supply unit. As an option, you can set up a  
redundant power supply with up to three additional power supply units. If a  
power supply unit fails, the redundant configuration assures continued  
operation. The defective power supply unit can be replaced during operation  
(for further details see section "Hot-plug power supply units" on page 119).  
16  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
     
Introduction  
Cooling  
Cooling of the system is ensured by two fans in each power supply unit and by  
the fan modules. Each of the fan units contains 2 fans. The fan modules have  
the same aspect ratio as the power supply units. Empty power supply  
installation bays must be fitted with fan modules. The configuration is redundant  
and offers hot-swap functionality (for more information, see "Hot-plug power  
supply units" on page 119).  
High level of availability and failure protection  
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in  
the event of an error and automatically "hides" the defective system  
components.  
The PDA (Prefailure Detection and Analyzing) technology from Fujitsu  
Technology Solutions analyzes and monitors all components that are critical for  
system reliability.  
The hot-swap components provide additional failure protection. Failure  
protection for the entire system is ensured by four redundant hot-swap power  
supply units as well as redundant hot-swap fans.  
Server management  
Server management is implemented using the ServerView Operations Manager  
supplied and the PDA (Prefailure Detection and Analysis) technology from  
Fujitsu. PDA reports the threat of a system error or overload at an early stage,  
allowing preventive measures to be taken.  
The ServerView Operations Manager enables the management of all  
PRIMERGY servers in the network via a central console. The ServerView  
Operations Manager supports the following functions:  
Round-the-clock monitoring, regardless of server status  
High-performance, graphical console bypass (AVR) protected by  
HTTPS/SSL (128 bit)  
Remote storage via USB  
Remote power on  
Temperature monitoring of the CPU and the surrounding area  
Detailed status and error reports for processors and main memory  
BX400 S1  
Operating Manual  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Introduction  
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)  
in the event that memory modules or processors fail  
Power monitoring  
End-of-life monitoring of fans with prompt notification before failure  
Watchdog timer for monitoring the operating system with ASR&R  
Further information on the ServerView Operations Manager is provided in the  
associated documentation.  
Service and support  
PRIMERGY servers are easy to maintain and modular, thus enabling quick and  
simple maintenance.  
The handles and locks (touch points) on the various hot pluggable components  
are colored green to ensure simple and immediate recognition.  
In order to prevent the components from being damaged by incorrect handling  
when they are being installed and removed, the areas of all components that  
can be touched without damaging them are also marked green.  
The redundant management blades and the optional remote test and  
diagnostics system ServerView Remote Management allows the PRIMERGY  
BX400 S1 blade servers to be serviced from a remote system. This enables  
remote diagnosis for system analysis, remote configuration and remote restart  
should the operating system or hardware fail.  
18  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Introduction  
1.4  
Notational conventions  
The following notational conventions are used in this manual:  
Text in italics indicates commands or menu items.  
"Quotation marks" indicate names of chapters and terms that are being  
emphasized.  
Ê
describes activities that must be performed in the order  
shown.  
V
CAUTION! pay particular attention to texts marked with this symbol.  
Failure to observe this warning may endanger your life,  
destroy the system or lead to the loss of data.  
I
indicates additional information, notes and tips.  
BX400 S1  
Operating Manual  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Introduction  
1.5  
Technical data  
Electrical data (hot-plug power supply unit)  
Rated voltage range  
Frequency  
100 - 240 V  
50 Hz-60 Hz  
Max. rated current  
Effective power  
Apparent power  
Heat dissipation  
45 A / 22.5 A (100-240 V)  
1785 W (240 V) 1200 W (100 V)  
1821 VA (240 V) 1265 VA (100 V)  
11520 kJ/h (with 3200 W) 5760 kJ/h  
(with1600 W)  
Main power fuse  
Protection class  
16 A  
I
Compliance with regulations and standards  
Product safety and  
ergonomics  
IEC 60950-1 / EN 60950-1, UL/CSA 60950-1 (all  
second edition is acquired)  
CNS 14336 / GB 4943 / EN 50371  
Electromagnetic  
compatibility  
GB 17625  
interference  
emissions  
EN 55022 class A  
Harmonic current EN 61000-3-2  
Flicker  
EN 61000-3-3  
interference  
immunity  
EN 55024, EN 300386  
to EU directives  
Electromagnetic compatibility 2004/108/EC  
EN 60721-3-3; class 3M2  
Mechanical  
environmental  
conditions  
20  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
       
Introduction  
Certification  
Product safety  
Global  
CB  
Europe  
ENEC  
Germany  
USA/Canada  
Japan  
GS, CE  
CSAUS / CSAC  
VCCI  
China/Taiwan  
BSMI  
Mechanical specifications  
Width  
Depth  
Height  
445 mm  
785 mm  
267 mm or 6 HU  
Weight  
Max. 98 kg (depending on the configuration).  
BX400 S1  
Operating Manual  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Introduction  
Ambient conditions  
Environment class 3K2  
Environment class 2K2  
EN 60721 / IEC 721 Part 3-3  
EN 60721 / IEC 721 Part 3-2  
Temperature:  
Operation (3K2)  
Transport (2K2)  
Humidity  
10 ºC .... 35 ºC  
-20 °C .... 60 °C  
10% ... 85% (non condensing)  
Condensation during operation must be avoided!  
Noise level  
Sound power level LWAd (ISO 9296)  
< 45 dB (standby)  
< 86 dB (operation)  
Sound pressure level at adjacent workstation  
< 64 dB (standby)  
< 64 dB (operation)  
L
pAm (ISO 9296)  
22  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
2
Installation steps, overview  
This chapter provides an overview of the installation steps for your BX400 S1  
system unit. Links take you to sections where you can find more detailed  
information about the respective steps:  
Ê
First read the chapter "Important notes" from page 25, particularly the  
section "Safety instructions".  
Ê
Unpack the system, check the delivery for damage sustained during  
transport and make sure it corresponds to the specifications in the delivery  
note (see section 4.2 on page 38).  
Ê
Ê
Set up the floorstand model (see section "Setting up the floorstand model"  
on page 39) or install the rack model in the rack (see section  
"Installing/removing the rack model" on page 40).  
Connect the cables (see 4.5 on page 49). Please also read the section  
"Instructions for connecting/disconnecting cables" on page 54.  
Ê
Ê
Connect the system to the mains (see 4.6 on page 51).  
Familiarize yourself with the control and display elements on the front and  
back of the system unit (see chapter 5 starting on page 55).  
Ê
Ê
Ê
Ê
Install the server blades and storage blades in the slots on the front of the  
system unit (see section 8.1 on page 82).  
Install the connection blades in the slots on the back of the system unit (see  
section 8.2 on page 88).  
Configure the management blades (see section 5.3 on page 68) so that you  
can carry out all further administration of the system unit via LAN.  
Install the required operating systems and applications on the server blades.  
For information see the relevant operating manuals.  
BX400 S1  
Operating Manual  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation steps, overview  
24  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
3
Important notes  
This chapter provides safety instructions which you must observe when  
handling your system.  
3.1  
Safety instructions  
I
The following safety instructions are also provided in the manual "Safety  
Notes and Regulations" or " 安全上のご注意 ".  
This device meets the relevant safety regulations for IT equipment. If you have  
any questions about whether you can install the server in the intended  
environment, please contact your sales outlet or our customer service team.  
V
CAUTION!  
The actions described in this manual shall be performed by technical  
specialists. A technical specialist is a person who is trained to install  
the server including hardware and software.  
Repairs to the device that do not relate to CSS failures shall be  
performed by service personnel. Please note that unauthorized  
interference with the system will void the warranty and exempt the  
manufacturer from all liability.  
Any failure to observe the guidelines in this manual, and any improper  
repairs could expose the user to risks (electric shock, energy  
hazards, fire hazards) or damage the equipment.  
Before installing/removing internal options to/from the server, turn off  
the server, all peripheral devices, and any other connected devices.  
Also unplug all power cords from the power outlet. Failure to do so  
can cause electric shock.  
BX400 S1  
Operating Manual  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Important notes  
Before starting up  
V
CAUTION!  
During installation and before operating the device, observe the  
instructions on environmental conditions for your device (see  
"Ambient conditions" on page 22).  
If the server has been moved from a cold environment, condensation  
may form both inside and on the outside of the machine.  
Wait until the server has acclimatized to room temperature and is  
absolutely dry before starting it up. Material damage may be caused  
to the server if this requirement is not met.  
Only transport the server in the original packaging or in packaging  
that protects it from impacts and jolts.  
For the Japanese market, transporting the device in its original  
packaging does not apply.  
Installation and operation  
V
CAUTION!  
The device may only be operated in a maximum ambient temperature  
of 35 °C.  
If the device is integrated in an installation that receives power from  
an industrial (public) power supply network with the IEC309  
connector, the (public) power supply protection must comply with the  
requirements for the non-industrial (public) power supply networks for  
the type B connector.  
The device automatically adjusts to a mains voltage in the range of  
100 - 240 V. Make sure that the local mains voltage is neither above  
nor below these limits.  
This device must only be connected to properly grounded power  
outlets or to the insulated sockets of the rack's internal power supply  
using safety-tested power cables.  
Make sure that the device is connected to a protective contact socket  
that is close by the device.  
26  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Important notes  
V
CAUTION!  
Make sure that the power sockets on the device or the grounded  
mains outlets are freely accessible.  
The On/Off button or the main power switch (if there is one) does not  
disconnect the device from the mains voltage. To completely  
disconnect it, you must remove all the power plugs from the power  
outlets.  
Always connect the device and the attached peripherals to the same  
power circuit. Otherwise you run the risk of losing data if, for example,  
a power outage occurs and the server is still running but the  
peripheral device (e.g. a storage subsystem) has failed.  
Data cables must be adequately shielded to avoid interference.  
For the LAN wiring, the requirements according to standards  
EN 50173 and EN 50174-1/2 apply. The minimum requirement is the  
use of a protected LAN cable of category 5 for 10/100-Mbit/s  
Ethernet, and/or of category 5e for Gigabit Ethernet. The  
requirements of the specification ISO/IEC 11801 must also be taken  
into account.  
Route the cables in such a way that they do not form a potential  
hazard (tripping) and cannot be damaged. When connecting the  
device, refer to the relevant notes in the operating manual.  
Do not connect or disconnect any data transmission cables during a  
thunderstorm (lightning hazard).  
Make sure that no objects (such as bracelets or paper clips) or liquids  
get inside the device (risk of electric shock or short circuit.  
In emergencies (e.g. damaged casing, control elements or power  
cable, penetration of liquids or foreign bodies), switch off the device  
immediately, unplug it from the grounded power outlets, and contact  
your customer service center.  
BX400 S1  
Operating Manual  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important notes  
V
CAUTION!  
Proper operation of the device (in accordance with IEC 60950-  
1/EN 60950-1) is only ensured if the casing is fully assembled and the  
rear covers for the installation bays are in place (electric shock,  
cooling, fire protection, interference suppression).  
Install only system extensions that satisfy the requirements and rules  
governing safety, electromagnetic compatibility, and  
telecommunications terminal equipment. If you install other  
extensions, you may damage the system or violate these safety  
regulations. Information on which system extensions are suitable can  
be obtained from the customer service center or your sales outlet.  
The components marked with a warning label (e.g. lightning symbol)  
should only be opened, removed or exchanged by authorized,  
qualified personnel. Exception: You may exchange hot-plug power  
supply units and CSS components.  
If you cause a defect on the device by installing or exchanging system  
extensions, the warranty will be invalidated.  
You may only set the resolutions and refresh rates specified in the  
operating manual for your monitor. Otherwise, you may damage the  
monitor. If you are in any doubt, contact your sales outlet or customer  
service center.  
28  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Important notes  
Working with CDs/DVDs/BDs and optical drives  
When working with devices with optical drives, these instructions must be  
followed.  
V
CAUTION!  
Only use CDs/DVDs/BDs that are in perfect condition, in order to  
prevent data loss, equipment damage and injury.  
Check each CD/DVD/BD for damage, cracks, breakages etc. before  
inserting it in the drive.  
Note that any additional labels applied may change the mechanical  
properties of a CD/DVD/BD and cause imbalance.  
Damaged and imbalanced CDs/DVDs/BDs can break at high drive  
speeds (data loss).  
Under certain circumstances, sharp CD/DVD/BD fragments can  
pierce the cover of the optical drive (equipment damage) and can fly  
out of the device (danger of injury, particularly to uncovered body  
parts such as the face or neck).  
High humidity and airborne dust levels are to be avoided. Electric  
shocks and/or server failures may be caused by liquids such as  
water, or metallic items, such as paper clips, entering a drive.  
Shocks and vibrations are also to be avoided.  
Do not insert any objects other than the specified CDs/DVDs/BDs.  
Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray  
roughly.  
Do not disassemble the optical drive.  
Before use, clean the optical disk tray using a soft, dry cloth.  
As a precaution, remove disks from the optical drive when the drive  
is not to be used for a long time. Keep the optical disk tray closed to  
prevent foreign matter, such as dust, from entering the optical drive.  
Hold CDs/DVDs/BDs by their edges to avoid contact with the disk  
surface.  
BX400 S1  
Operating Manual  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important notes  
Do not contaminate the CD/DVD/BD surface with fingerprints, oil,  
dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to  
the edge. Do not use benzene, thinners, water, record sprays,  
antistatic agents, or silicone-impregnated cloth.  
Be careful not to damage the CD/DVD/BD surface.  
Keep the CDs/DVDs/BDs away from heat sources.  
Do not bend or place heavy objects on CDs/DVDs/BDs.  
Do not write with ballpoint pen or pencil on the label (printed) side.  
Do not attach stickers or similar to the label side. Doing so may cause  
rotational eccentricity and abnormal vibrations.  
When a CD/DVD/BD is moved from a cold place to a warm place,  
moisture condensation on the CD/DVD/BD surface can cause data  
read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth  
then let it air dry. Do not dry the CD/DVD/BD using devices such as a  
hair dryer.  
To avoid dust, damage, and deformation, keep the CD/DVD/BD in its  
case whenever it is not in use.  
Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to  
prolonged direct sunlight or near heating appliances are to be  
avoided.  
I
You can prevent damage from the optical drive and the CDs/DVDs/BDs,  
as well as premature wear of the disks, by observing the following  
suggestions:  
Only insert disks in the drive when needed and remove them after  
use.  
Store the disks in suitable sleeves.  
Protect the disks from exposure to heat and direct sunlight.  
Laser information  
The optical drive complies with IEC 60825-1 laser class 1.  
V
CAUTION!  
The optical drive contains a light-emitting diode (LED), which under  
certain circumstances produces a laser beam stronger than laser  
class 1. Looking directly at this beam is dangerous.  
Never remove parts of the optical drive casing!  
30  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Important notes  
Batteries  
CAUTION!  
V
Incorrect replacement of batteries may result in a risk of explosion.  
The batteries may only be replaced with identical batteries or with a  
type recommended by the manufacturer (see the Technical Manual  
of the server blade).  
Do not throw batteries into the trash can. They can be returned free  
of charge to the manufacturer, dealer or an authorized agent for  
recycling or disposal.  
The battery must be disposed of in accordance with local regulations  
concerning special waste.  
Replace the lithium battery in the server blade in accordance with the  
instructions in the Technical Manual of the server blade.  
All batteries containing pollutants are marked with a symbol (a  
crossed-out garbage can). They are also marked with the chemical  
symbol for the heavy metal that causes them to be categorized as  
containing pollutants:  
Cd Cadmium  
Hg Mercury  
Pb Lead  
BX400 S1  
Operating Manual  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Important notes  
Modules with Electrostatic-Sensitive Devices  
Modules with electrostatic-sensitive devices are identified by the following  
sticker:  
Figure 1: ESD label  
When you handle components fitted with ESDs, you must always observe the  
following points:  
Switch off the system and remove the power plugs from the power outlets  
before installing or removing components with ESDs.  
You must always discharge static build-up (e.g. by touching a grounded  
object) before working with such components.  
Any devices or tools that are used must be free of electrostatic charge.  
Wear a suitable grounding cable that connects you to the external chassis  
of the system unit.  
Always hold components with ESDs at the edges or at the points marked  
green (touch points).  
Do not touch any connectors or conduction paths on an ESD.  
Place all the components on a pad which is free of electrostatic charge.  
I
For a detailed description of how to handle ESD components, see the  
relevant European or international standards (EN 61340-5-1,  
ANSI/ESD S20.20).  
Other important information:  
During cleaning, observe the instructions in section "Cleaning the system  
unit" on page 73.  
32  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Important notes  
Keep this operating manual and the other documentation (such as the  
technical manual, documentation DVD) close to the device. All  
documentation must be included if the equipment is passed on to a third  
party.  
3.2  
CE conformity  
The system complies with the requirements of the EC directives  
2004/108/EC regarding "Electromagnetic Compatibility" and  
2006/95/EC "Low Voltage Directive". This is indicated by the CE  
marking (CE = Communauté Européenne).  
3.3  
Transporting the system unit  
V
CAUTION!  
Only transport the system unit in its original packaging or in suitable  
packaging which protects it from knocks and jolts.  
For the Japanese market, transporting the device in its original  
packaging does not apply.  
Only unpack the system unit at the place where you want to set it up.  
Ask someone for help with carrying the system unit. Because the  
PRIMERGY BX400 S1 system unit is large and heavy, at least two  
people are needed.  
Before lifting the system unit, remove all server blades, storage  
blades, connection blades, management blades, all power supply  
units, fan units and dummy modules to reduce the weight.  
Only lift or carry the system unit by the handles on the long sides.  
Never lift or carry the system unit by the handles on the front or back.  
BX400 S1  
Operating Manual  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Important notes  
3.4  
Notes on installation into the rack  
V
CAUTION!  
For safety reasons, at least two people are required to install the  
system unit in the rack because of its weight and size.  
(For the Japanese market, please refer to " 安全上のご注意 ".)  
Before lifting the system unit, remove all server blades, storage  
blades, connection blades, management blades, all power supply  
units, fan units and dummy modules to reduce the weight.  
To lift or carry the system unit, always use the handles on the long  
sides.  
Never lift or carry the system unit by the handles on the front or back  
of the unit.  
For safety reasons, no more than one unit may be removed from the  
rack at any one time during installation or maintenance work.  
Make sure that the anti-tilt plate is correctly mounted when you set up  
the rack.  
The rack may tip over if more than one unit is removed at the same  
time.  
Before connecting or disconnecting cables, read the notes in the  
chapter "Important Notes" in the technical manual for the relevant  
rack. The technical manual for the rack is supplied with the rack.  
The rack must be connected to the mains by an authorized specialist  
(electrician).  
If the server system is integrated in a rack installation that receives  
power from an industrial (public) power supply network with the  
IEC309 connector, the (public) power supply protection must comply  
with the requirements for the non-industrial (public) power supply  
networks for the type A connector.  
The power supply for the rack should be distributed over the three  
phases of a three-phase mains connection.  
34  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Important notes  
3.5  
Environmental protection  
Environmentally-friendly product design and development  
This product has been designed in accordance with the Fujitsu standard for  
"environmentally friendly product design and development". This means that  
key factors such as durability, selection and labeling of materials, emissions,  
packaging, ease of dismantling and recycling have been taken into account.  
This saves resources and thus reduces the harm done to the environment.  
Further information can be found at:  
http://ts.fujitsu.com/products/standard_servers/index.html (for the EMEA  
market)  
Energy-saving information  
Devices that do not need to be constantly switched on should be switched off  
until they are needed as well as during long breaks and after completion of work.  
Packaging information  
This packaging information doesn’t apply to the Japanese market.  
Do not throw away the packaging. You may need it later for transporting the  
system. If possible, the equipment should only be transported in its original  
packaging.  
Information on handling consumables  
Please dispose of printer consumables and batteries in accordance with the  
applicable national regulations.  
In accordance with EU directives, batteries must not be disposed of with  
unsorted domestic waste. They can be returned free of charge to the  
manufacturer, dealer or an authorized agent for recycling or disposal.  
BX400 S1  
Operating Manual  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Important notes  
All batteries containing pollutants are marked with a symbol (a crossed-out  
garbage can). They are also marked with the chemical symbol for the heavy  
metal that causes them to be categorized as containing pollutants:  
Cd Cadmium  
Hg Mercury  
Pb Lead  
Labels on plastic casing parts  
Please avoid sticking your own labels on plastic parts wherever possible, since  
this makes it difficult to recycle them.  
Returns, recycling and disposal  
Please handle returns, recycling and disposal in accordance with local  
regulations.  
The device must not be disposed of with domestic waste. This  
device is labeled in compliance with European directive  
2002/96/EC on waste electrical and electronic equipment (WEEE).  
This directive sets the framework for returning and recycling used  
equipment and is valid across the EU. When returning your used  
you. Further information can be found at  
http://ts.fujitsu.com/recycling.  
Details regarding the return and recycling of devices and consumables within  
Europe can also be found in the "Returning used devices" manual, via your local  
Fujitsu branch or from our recycling center in Paderborn:  
Fujitsu Technology Solutions  
Recycling Center  
D-33106 Paderborn  
Tel. +49 5251 525 1410  
Fax +49 5251 525 32 1410  
36  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
4
Installing the hardware  
V
CAUTION!  
Follow the safety instructions in chapter "Important notes" on  
page 25.  
The server must not be exposed to extreme environmental conditions  
(see "Ambient conditions" on page 22). Protect the server from dust,  
humidity and heat.  
The server must be acclimatized to its operating environment for the  
time specified in the table before you operate it.  
Temperature difference (°C)  
(hours)  
5
3
5
10  
15  
7
20  
8
25  
30  
9
10  
Table 1: Acclimatization times  
In the table "Acclimatization times", temperature difference refers to  
the difference between the temperature of the operating environment  
and the temperature to which the server was previously exposed  
(outside, transport or storage temperature).  
BX400 S1  
Operating Manual  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installing the hardware  
4.1  
Installation procedure  
The following installation steps are described in detail in the following sections  
of this chapter:  
Unpacking the system unit (see 4.2 on page 38).  
Installing the system unit in the rack (see 4.4 on page 40 and configuration  
diagram on the order lists) or setting up the floorstand model (see section  
"Setting up the floorstand model" on page 39).  
Connecting the cables of the system unit (see 4.5 on page 49). Please also  
read the section "Instructions for connecting/disconnecting cables" on  
page 54.  
Connecting the system unit to the mains (see 4.6 on page 51).  
4.2  
Unpacking the system unit  
V
CAUTION!  
Follow the safety instructions in chapter "Important notes" on page 25.  
The server must always be lifted or carried by at least two people.  
(For the Japanese market, please refer to " 安全上のご注意 ".)  
Do not unpack the server until it is at its installation location.  
Ê
Ê
Transport the system unit to the place where you want to set it up.  
Unpack all individual parts.  
Keep the original packaging in case you want to transport the system unit  
again (applies only to EMEA market).  
Ê
Ê
Check the delivery for any damage during transport.  
Check whether the items delivered match the details on the delivery note.  
The product name and serial number of the product can be found on the ID card  
(see section 5.1.1.3 on page 60).  
Ê
Notify your supplier immediately should you discover that the items  
delivered do not correspond to the delivery note.  
38  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
           
Installing the hardware  
4.3  
Setting up the floorstand model  
I
If you are not installing a PRIMERGY BX400 S1 system unit floorstand  
model, skip this section and continue reading at section  
V "Installing/removing the rack model" on page 40.  
CAUTION!  
Follow the safety instructions in chapter "Important notes" on page 25.  
Transport the system unit to the place where you want to set it up.  
Ê
Ê
Unpack the system unit (see section "Unpacking the system unit" on  
page 38).  
Ê
Set up the system unit.  
V
CAUTION!  
maintained.  
Access to the rear of the system unit must be assured so that  
other devices (e.g. memory subsystems) can be connected.  
A clearance of at least 200 mm must be maintained in front of and  
behind the system to ensure proper ventilation.  
The mains plug must be accessible easily and safely.  
Ê
Ê
Lock the casters.  
Wire the system unit. Read the information in section "Connecting devices  
to the system unit" on page 49 and section "Instructions for  
connecting/disconnecting cables" on page 54.  
Ê
Connect the system to the mains (see section "Connecting the system unit  
to the mains" on page 51).  
BX400 S1  
Operating Manual  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the hardware  
4.4  
Installing/removing the rack model  
V
CAUTION!  
Follow the safety instructions in chapter "Important notes" on page 25  
and section "Notes on installation into the rack" on page 34.  
Because the PRIMERGY BX400 S1 system unit is large and heavy,  
at least two people are needed to safely mount it in the rack or  
remove it from the rack. (For the Japanese market, please refer to "  
安全上のご注意 ".)  
The rack may tip over if more than one unit is removed at the same  
time.  
4.4.1 Rack system requirements  
The rack systems from Fujitsu PRIMECENTER Rack, DataCenter Rack and  
19-inch standard rack (for the Japanese market) support the installation of  
PRIMERGY servers. Installation in most current rack systems from other  
manufacturers (3rd party racks) is also supported.  
To accommodate the ventilation concept and ensure proper ventilation, any  
unused areas in the rack must be sealed using dummy covers.  
The power is supplied via the multiple socket outlets fitted in the rack.  
Fujitsu rack systems  
The main features of PRIMECENTER Rack, DataCenter Rack and 19-inch  
standard rack (for the Japanese market) are as follows:  
support systems having a linear alignment feature to ensure that they can  
be adjusted to different rack depths  
PRIMECENTER Rack and DataCenter Rack provide an enhanced cable  
management in the lateral rack area.  
I
For PRIMECENTER Racks and DataCenter Racks:  
The mounting of the rails in the different racks is described in the next  
sections. Installation of the cable management is described in detail in  
the Technical Manual for the respective rack.  
40  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
         
Installing the hardware  
I
For 19-inch standard rack (for the Japanese market):  
For information on mounting of the rails in the 19-inch standard rack (for  
the Japanese market) please refer to the next sections.  
3rd party racks  
Certain general conditions must be met:  
Installation dimensions (see the dimensions shown in figure 2 on page 42):  
1
Front of rack  
2
Rear of rack  
A
Rack depth (comparison PRIMECENTER Rack 940/1000/1100 mm)  
Rack width (comparison PRIMECENTER rack 700 mm)  
Clearance for 19" installation level  
Front 19" installation level  
B
C
C1  
C2  
D
Rear 19" installation level  
Cable routing area (cable area depth) and ventilation  
Space for front panel and ventilation  
Space for right and left support systems  
PRIMERGY server installation depth  
Front left support upright  
E
F
P
a1  
a2  
b1  
b2  
Front right support upright  
Rear left support upright  
Rear right support upright  
BX400 S1  
Operating Manual  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the hardware  
+/- 1,6mm  
Figure 2: Mechanical requirements  
42  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Installing the hardware  
You must ensure that the safety mechanisms on the server, e.g. stoppers or  
retaining systems, are functioning correctly.  
The shape of the rack support uprights must ensure that the support  
systems can be bolted to the front.  
The support systems have a linear alignment feature to ensure that they can  
be adjusted to different rack depths.  
No cable management support (delivered with the mounting kit).  
Climatic conditions:An unobstructed air intake in the rack front and air  
discharge in the rear cover of the rack are essential for ventilation of the  
installed server.  
In general, the ventilation concept ensures that the necessary cooling is  
achieved by the horizontal self-ventilation of the installed devices (air flow  
from the front to the rear).  
Power supply:For installation in 3rd party racks, you must ensure that the  
appropriate socket strips are present.  
4.4.2 Installation in the rack  
For installation in a PRIMECENTER/DataCenter rack, the following parts are  
required:  
Two 3-HU Support brackets (for the EMEA market)  
Two carrier rails (mounted)  
Two holding-down clamps  
I
General information regarding server installation in the rack is included  
in the technical manual for the appropriate rack.  
When mounting the left carrier rail in the PRIMECENTER/DataCenter rack, the  
supplied support bracket must first be mounted on the rear left support upright  
flush with the bottom edge of the device.  
Ê
Read the installation guide in the technical manual for the corresponding  
rack.  
Ê
Mark the position of the bottom edge of the system unit on the support  
uprights.  
BX400 S1  
Operating Manual  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the hardware  
0
0
/
/
Figure 3: Attaching the support brackets  
Ê
Position the support brackets at the relevant height on the rear left support  
upright (place knob in the corresponding hole) and secure them using four  
centering screws (1).  
Ê
Ê
Fasten the holding-down clamp at the upper end of the support bracket  
using two centering screws (2).  
Fasten the second holding-down clamp at the same height as the first one  
to the rear left support upright using two centering screws.  
44  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Installing the hardware  
/
0
1
Figure 4: Attaching the left carrier rail  
Ê
Position the carrier rail in the support bracket (insert knob) - see (1).  
For the Japanese market:  
I
There is no support bracket. Please position the support system  
directly on the support upright.  
Ê
Fasten the carrier rail at the lower end of the support bracket using three  
centering screws (2).  
Ê
Ê
Position the carrier rail in the front left support upright.  
Fasten the carrier rail to the front support upright (3) using three M5 screws  
including plugwashers.  
Ê
Repeat the operation for the right carrier rail. This rail does not require a  
support bracket.  
BX400 S1  
Operating Manual  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the hardware  
17  
17  
15  
10  
5
1
Figure 5: Position of the cage nuts  
Ê
Fit the cage nuts for securing the system unit in the corresponding catches  
on the right and left support uprights.  
4.4.3 Installing/removing the system unit  
V
CAUTION!  
Because the PRIMERGY BX400 S1 system unit is large and  
heavy, at least two people are needed to safely mount it in the  
rack or remove it from the rack.  
Please observe the safety information and notes on rack installation  
in the chapter "Important notes" on page 34.  
Before lifting the system unit, remove all server blades, storage  
blades, connection blades, management blades, all power supply  
units, fan units and dummy modules to reduce the weight.  
Only lift or carry the system unit by the handles on the long sides.  
Never lift or carry the system unit by the handles on the front or back.  
Ê
Make a note of the positions of the individual server blades and storage  
blades, the connection blades, power supply units and fan modules in the  
system unit for reinstallation.  
46  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
Installing the hardware  
Ê
Remove all server blades, storage blades, connection blades, management  
blades, all power supply units, fan units and dummy modules from the  
system unit. For assembly instructions see chapter "Hot-plug components"  
on page 81.  
0
0
/
Figure 6: Placing the system unit on the rack rails  
Ê
Ê
Ê
Lift the back end of the system unit onto the carrier rails in the rack.  
Fold in the two carrying handles (1).  
Push the system unit into the rack (2).  
BX400 S1  
Operating Manual  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the hardware  
Figure 7: Installing the system unit  
Ê
Ê
Ê
Push the system unit into the rack as far as it will go.  
Fasten the system unit to the rack using the two knurled screws.  
Reinstall the server blades, storage blades, connection blades and  
management blades, power supply units, fan units and dummy modules in  
their old bays, see page 46. For assembly instructions see chapter "Hot-  
plug components" on page 81.  
V
CAUTION!  
Incorrect fitting of the system unit may lead to serious errors.  
Removing the system unit  
CAUTION!  
Make a note of the positions of the individual server blades, storage  
V
blades, connection blades, power supply units and fan modules in the  
system unit for reinstallation.  
To remove the system unit, follow the installation instructions in reverse.  
48  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Installing the hardware  
4.5  
Connecting devices to the system unit  
On the back of the system unit are the ports for the network connection and the  
administration of the blade server.  
Ports on the back of the system unit  
/
0 1  
2 3  
MMB 1  
CB 1  
MMB 2  
CB 2  
CB 3  
CB 4  
Figure 8: Ports for external devices (rack version)  
CB 1 -4  
Slots for connection blades. For information on the ports of the connection  
blades, see "Connection blades" on page 88.  
MMB 1,2 The management blades have the following ports  
1
2
3
Service LAN port (as a point-to-point connection, for system unit  
administration only, no access to server blades and connection blades)  
USB ports for backing up and restoring the MMB configuration and for  
access to logging information  
Serial port for a local management console  
4,5 Management LAN ports for blade server management (including server  
blades and connection blades)  
I
The service LAN port (pos. 1 in figure 8), the management LAN ports for  
blade server management (pos. 4 and 5 in figure 8) and the  
management LAN port of the FSIOM (pos. 3 in figure 9) must be in  
different LAN subnetworks.  
BX400 S1  
Operating Manual  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the hardware  
It is recommended to operate the management blade user interface in a  
separate broadcast domain for the server management.  
Ê
Connect the data cables according to the system configuration you require.  
Connectors on the front of the system unit  
/
0
1
Figure 9: Connectors for external devices on the Front-Side I/O Module (FSIOM)  
1
USB connectors to connect external devices to the server blades,  
controlled by the management blade  
2
3
Serial connector for a local management console  
LAN connector for blade server management (including server blades  
and connection blades)  
For information on the front side connectors of the server blades for local  
administration, see the operating manuals for the relevant server blades.  
50  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Installing the hardware  
4.5.1 Cable routing  
The cables are routed along the support uprights of the rack.  
4.6  
Connecting the system unit to the mains  
The system unit has four bays for hot-swap power supply units. In the base  
configuration, it is fitted with one power supply unit.  
V
CAUTION!  
Read the information on determining how many power supply units  
are required (see "Hot-plug power supply units" on page 119).  
The power supply units automatically adjust to a mains voltage  
between 100 - 240 V. The system unit may only be used if the local  
mains voltage is within the voltage range of the system.  
The 1600 W power supply units may only be connected to 16 A  
power outlets, a UPS, a 32 A power distribution unit, or CEE sockets.  
When ordering the system unit, you must specify which socket type  
is available at the installation location, so that the cables with the  
appropriate C19 connectors can be supplied.  
For the Japanese market:  
The 1600W power supply units may only be connected to NEMA  
L6-15, IEC 60320-C20, or NEMA 5-15 sockets.  
Always connect the cable first to the power supply unit and then to the  
mains.  
Ê
First connect the insulated C19 connector of the power cable to the power  
supply units of the system unit, and then plug the connector into the UPS,  
power distribution unit or an external socket. The system can be configured  
to support *True AC redundancy or non-AC redundancy.  
I
True AC redundancy is recommended for systems used for critical  
business applications. This will result in the system to continue operation  
during a power failure as the redundant part of the subsystem is plugged  
I into a separate AC source [e.g. uninterruptable power supply (UPS)).  
Refer to tables below for maximum DC loading for both AC redundant  
and AC non redundant configurations.  
BX400 S1  
Operating Manual  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installing the hardware  
Installation requirements for AC redundant configurations  
The AC redundant configuration is with two PSUs plugged into a main AC  
source and two other PSUs plugged into a separate AC source (e.g. UPS).  
PSU configuration  
Max. DC loading  
4800 W  
DC redundancy  
2 + 1  
2 + 2  
Yes  
Yes  
6400 W  
Table 2: Maximum DC loading requirements  
Installation requirements for non AC redundant configurations  
For systems not requiring AC redundancy, the power supply can be installed  
with up to 4 PSUs. The PSUs can be connected to a single or multiple AC  
sources.  
PSU configuration  
Max. DC loading  
3200 W  
DC redundancy  
2
No  
Yes  
Yes  
2 + 1  
2 + 2  
4800 W  
6400 W  
Table 3: Maximum DC loading requirements  
52  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Installing the hardware  
4.6.1 Using cable ties  
If you wish, you can secure the power cable with a cable tie to prevent the C19  
connector from being pulled out of the server accidentally. The cable tie is  
included in the accessories pack that is delivered together with the server.  
/
Figure 10: Using cable ties  
Ê
Ê
Route the cable through the loop of the cable tie.  
Pull the cable tie tight to secure the power cable.  
The insulated connector cannot now be disconnected from the server  
accidentally.  
I
You can undo the cable tie by bending back the zip strip at the fastening  
point (1).  
BX400 S1  
Operating Manual  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the hardware  
4.7  
Instructions for connecting/disconnecting  
cables  
V
CAUTION!  
Please make sure you read the documentation for the devices before  
you try to connect them.  
Do not connect or disconnect any data transmission cables during a  
thunderstorm.  
Always pull cables out by the plug.  
When connecting and disconnecting the cables, observe the following  
order.  
Connecting cables  
Ê
Ê
Switch off all the relevant devices.  
Unplug the power plugs of all affected devices from the power outlets or CEE  
sockets.  
Ê
Ê
Ê
Connect all cables to the server and the peripherals. Secure the connectors  
of the data cables (e.g. by tightening the screws).  
Plug all data transmission cables into the sockets provided for the data or  
telecommunication networks.  
Plug all the power plugs into the power outlets or CEE sockets.  
Disconnecting cables  
Ê
Ê
Switch off all the relevant devices.  
Unplug the power plugs of all affected devices from the power outlets or CEE  
sockets.  
Ê
Ê
Pull all data transmission cables out of the sockets provided for the data or  
telecommunication networks.  
Undo the screws on the connectors and pull the relevant cables out of the  
system unit and peripherals.  
54  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
       
5
Installation and operation  
V
CAUTION!  
Follow the safety instructions in the chapter "Important notes" on  
page 25.  
5.1  
Control and display elements  
5.1.1 Front of system  
The BX400 S1 system unit has an option for a fold-out ServerView Local  
Service Display for Blade on the front. It is controlled by the management blade  
and is used for local diagnostics and administration of the blade server. It is also  
used for the initial configuration of the management blades, see "Configuring  
management blades" on page 68.  
Figure 11: ServerView Local Service Display for Blade (rack version)  
The most important control and display elements can also be found on the front  
of the ServerView Local Service Display for Blade. This means they are also  
available when it is folded away.  
I
The control and display elements of the server blades and storage  
blades are described in the relevant operating manuals.  
BX400 S1  
Operating Manual  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Installation and operation  
Figure 12: Locking the ServerView Local Service Display for Blade (rack version)  
V
CAUTION!  
Press the touch point (see arrow) of the ServerView Local Service  
Display for Blade before you push it back into the frame of the system  
unit.  
Figure 13: ServerView Local Service Display for Blade (floorstand version)  
At the BX400 S1 system unit floorstand version, the ServerView Local Service  
Display for Blade is placed on top of the system unit.  
56  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Installation and operation  
1
2
3 4 5 6  
7
Figure 14: Control and display elements on the front of the ServerView Local Service Display  
for Blade  
1
2
3
4
CSS indicator  
Global Error indicator  
ID button  
5
6
7
power-on indicator  
ID indicator  
Navigation buttons for the  
LocalView menu system  
On/Off button  
BX400 S1  
Operating Manual  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and operation  
5.1.1.1 Control elements  
On/Off button  
When the system is switched off, it can be switched on again by  
pressing the On/Off button.  
When the system is operating, pressing the On/Off button will  
switch off the system.  
V
CAUTION!  
I Risk of loss of data!  
The On/Off button does not disconnect the server from the  
mains voltage. To disconnect from the mains completely,  
remove the power plug(s).  
ID  
ID button  
Lights up (blue) on the front and on the rear of the system unit when  
the ID button is pressed. The two ID indicators are synchronized.  
Navigation buttons for the LocalView menu system  
With the buttons  
,
,
and  
you select a function. Pressing  
the button executes the selected function.  
5.1.1.2 LEDs on the control panel  
Power indicator (two-color)  
Lights up green when the system unit is switched on.  
Lights up orange when the system unit is switched OFF, but mains  
voltage is present (standby mode).  
58  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
         
Installation and operation  
Global Error indicator (orange)  
Lights up orange if a prefailure event has been detected that  
requires (precautionary) service intervention.  
Flashes orange if an error was detected that requires service  
intervention.  
!
Does not light up if there is no critical event.  
If the event is still acute after a power failure, the indicator is  
activated after the restart.  
The indicator also lights up in standby mode.  
You can find more details on the indicated errors in the System  
Event Log (SEL), in the management blade web interface, on the  
ServerView Local Service Display for Blade, in the ServerView  
Operations Manager or via the iRMC S2's Web interface.  
CSS  
CSS indicator (yellow)  
Lights up yellow if a prefailure event was detected for a CSS  
component that you can fix yourself (for reasons of  
precaution) with the CSS concept.  
Flashes yellow if an error was detected that you can fix  
yourself with the CSS concept.  
Does not light up when the system is OK.  
If the event is still acute after a power failure, the indicator is  
activated after the restart.  
The indicator also lights up in standby mode.  
For more information on the CSS concept, see "Customer Self  
Service (CSS)" on page 13.  
ID  
ID indicator (blue):  
Glows blue when the system was selected by pressing the ID  
button. Pressing the button again deactivates the LED.  
The ID indicator can also be activated via the management blade  
web interface and via the ServerView Operations Manager and its  
status reported to the ServerView Operations Manager and the  
iRMC S2.  
BX400 S1  
Operating Manual  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation and operation  
5.1.1.3 System ID card  
Rack model  
Floorstand model  
Figure 15: System ID card location  
The ID card contains various system information, such as the product  
name,serial number, order number (in the Japanese market, only the product  
name, the serial number).  
60  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Installation and operation  
5.1.2 Back of system  
5.1.2.1 Control and display elements on the management blade  
1 2 3  
4 5  
6
7 8 9 10 11  
Figure 16: Control and display elements on the management blade  
1
2
3
Status indicator (orange)  
Lights up when the management blade is active (master)  
Is not lit when the management blade is not active (slave)  
Blinks when the management blade is defective.  
LAN activity indicator (service LAN connection)  
Lights up green if a LAN connection exists.  
Does not light up if no LAN connection exists.  
Flashes green when a LAN transfer is in progress.  
LAN transfer-rate indicator (service LAN port)  
Lights up green for a LAN transfer rate of 100 Mbit/s.  
Does not light up for a LAN transfer rate of 10 Mbit/s.  
BX400 S1  
Operating Manual  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation and operation  
4
Global Error indicator (orange)  
Lights up orange if a prefailure event has been detected that  
requires (precautionary) service intervention.  
Flashes orange if an error was detected that requires service  
intervention.  
Does not light up if there is no critical event.  
If the event is still acute after a power failure, the indicator is activated  
after the restart.  
The indicator also lights up in standby mode.  
You can find more details on the indicated errors in the System Event  
Log (SEL), in the management blade web interface, on the ServerView  
Local Service Display for Blade, in the ServerView Operations Manager  
or via the iRMC S2's Web interface.  
5
CSS indicator (yellow)  
Lights up yellow if a prefailure event was detected for a CSS  
component that you can fix yourself (for reasons of precaution) with  
the CSS concept.  
Flashes yellow if an error was detected that you can fix yourself  
with the CSS concept.  
Does not light up when the system is OK.  
If the event is still acute after a power failure, the indicator is activated  
after the restart.  
The indicator also lights up in standby mode.  
For more information on the CSS concept, see "Customer Self Service  
(CSS)" on page 13.  
6
Identification (ID) button with ID LED (blue)  
ID indicators on the front and rear of the server light up when the ID  
button is pressed. The two ID indicators are synchronized. To  
deactivate, press the button again.  
The ID indicator can also be activated via the management blade web  
interface and via the ServerView Operations Manager and its status  
reported to the ServerView Operations Manager.  
62  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
     
Installation and operation  
7, 9 LAN activity indicator (management LAN ports)  
Lights up green if a LAN connection exists.  
Does not light up if no LAN connection exists.  
Flashes green when a LAN transfer is in progress.  
8, 10 LAN transfer-rate indicator (management LAN ports)  
Lights yellow for a LAN transfer rate of 1 Gbit/s.  
Lights up green for a LAN transfer rate of 100 Mbit/s.  
Does not light up for a LAN transfer rate of 10 Mbit/s.  
11  
Hidden reset button  
BX400 S1  
Operating Manual  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation and operation  
5.1.2.2 Indicator on the hot-plug power supply units  
1
Figure 17: Indicator on the hot-plug power supply unit  
1
Mains power indicator (two-color)  
Flashes green when the system unit is switched off but still  
connected to the mains (standby mode).  
Lights up green when the system unit is switched on and is working  
properly.  
Lights up yellow when a prospective error has been detected in the  
power supply unit but the latter is still active.*  
*
The following events are detected as predictable errors:  
The temperature is very high.  
The power consumption is very high.  
The current strength is very high.  
64  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
Installation and operation  
5.1.2.3 Indicators on the hot-plug fan modules  
1
Figure 18: Indicators on the hot-plug fan module  
1
Power indicator (two-color)  
Flashes green when the system unit is switched off but still  
connected to the mains (standby mode).  
Lights up green when the system unit is switched on and the fan  
module is working properly.  
Lights up yellow when a prospective error has been detected in the  
fan module but the latter is still active.  
BX400 S1  
Operating Manual  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation and operation  
5.2  
Switching the system unit on/off  
V
CAUTION!  
If you switch on the system unit and the connected monitor only  
shows flickering stripes, switch it off immediately (see chapter  
"Troubleshooting and tips" on page 77).  
The On/Off button does not disconnect the device from the mains. To  
fully disconnect it from the mains, you must unplug the plugs from the  
sockets.  
Turn the system unit on when the temperature is in its operating  
environment range (10–35°C). For details on the operating  
environment, refer to "Safety Precautions". When operating the  
device outside of this operating environment, the server may operate  
improperly, damage data etc. Furthermore, Fujitsu cannot be held  
responsible for any related damage,malfunction, or loss of data, etc.  
Be sure to wait for 10 seconds or more after shutdown before turning  
the system unit on.  
Before switching the system unit on using the On/Off button, the  
PRIMERGY BX400 S1 system unit must be connected to the power  
supply for at least a minute.  
Switching on the system unit  
Ê
Press the On/Off button on the system unit (position 4 in figure 14 on  
page 57) for 2 seconds. Depending on the BIOS setting, the individual  
server blades will also be switched on. This is done in sequence according  
to the numbering of the server blade slots (see figure 20 on page 82.)  
Ê
If necessary, switch on the required server blades  
The system unit is switched on and the activated server blades perform a  
system test and boot the operating system.  
Switching off the system unit  
The system unit is up and running (server blades are also switched on).  
Ê
To properly shut down all server blades, press the On/Off button on the  
front of the system unit (position 4 in figure 14 on page 57) for 4 seconds. All  
server blades will then be shut down.  
66  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
Installation and operation  
Ê
To immediately shut down all server blades, press the On/Off button on  
the front of the system unit (position 4 in figure 14 on page 57) for 10  
seconds. All server blades are switched off immediately.  
Other ways to shut down the system unit  
Web interface of the management blade  
You can also switch off the system unit and the individual server blades via  
the Web interface of the management blade (see manual "PRIMERGY  
BX400 Blade Server Systems ServerView Management Blade S1 User  
Interface Description").  
After power failure  
After a power failure, the system unit will switch itself on again automatically,  
and the server blades which were running prior to the power failure are  
automatically started up again according to the BIOS setting.  
I
How to switch server blades on/off is described in the relevant operating  
manuals.  
BX400 S1  
Operating Manual  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and operation  
5.3  
Configuring management blades  
The two redundant management blades form the central interface for  
administration of the system unit and all components therein. This section  
explains how to do the initial configuration of the management blades.  
For more information on administration of the blade server, see the manual  
"PRIMERGY BX400 Blade Server Systems ServerView Management Blade S1  
User Interface Description").  
Initial configuration with the Base Configuration Wizard  
Ê
Make sure that the hardware installation of the system unit as described in  
chapter "Installing the hardware" on page 37.  
Ê
Press the On/Off button on the ServerView Local Service Display for Blade  
(position 4 in figure 14 on page 57) to switch on the system unit.  
The management blade boots and the ServerView Local Service Display for  
Blade shows the start menu of the Base Configuration Wizard.  
Figure 19: Base Configuration Wizard start menu  
Ê
Select YES with the nagivation buttons and press the  
button to start the  
wizard.  
The NO button closes the Base Configuration Wizard, and the Health Status  
Overview menu is displayed.  
68  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Installation and operation  
The wizard guides you step by step through the menus, in which you make the  
necessary settings for putting the blade server into operation. You operate the  
wizard with the Previous, Next, and Cancel buttons. The Finish button closes it.  
However, you cannot close the wizard until you have defined the following  
default settings:  
Language  
Date/Time  
Identification  
Network  
Language  
Date/Time  
Import  
Defines the language for the menu (English, German or  
Japanese)  
Contains the time and the time zone and activates/deactivates  
summer time.  
If you have activated this option you can import the following  
parameters:  
Language  
Identification  
Network  
PIN  
Power  
Click Next and specify the path and file name of the configuration  
file on the USB storage medium.  
Ident.  
Contains details of:  
System Name  
Rack Name  
System Contact  
System Location  
BX400 S1  
Operating Manual  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and operation  
Network  
If DHCP is activated (default), the obtained network data is  
displayed. Otherwise you can specify the network data manually:  
IP Address  
Subnet Mask  
Gateway  
IPv4 settings  
IPv4 enable  
Obtain IP address from DHCP  
Obtain DNS address from DHCP  
DNS server 1  
DNS server 2  
IPv6 settings  
IPv6 enable  
Obtain IP address from DHCP  
Obtain DNS configuration from DHCP  
DNS server 1  
DNS server 2  
I/O  
Contains basic configuration settings for the Front-Side I/O  
Module (FSIOM) and the connection blades:  
FSIOM settings  
Select server blades for using USB port and DVD drive  
Connection blade settings (management port IPv4):  
If DHCP is activated (default), the obtained network data is  
displayed. Otherwise you can specify the network data manually:  
IP Address  
Subnet Mask  
Gateway  
Connection blade settings (management port IPv6):  
IPv6 enabled (OFF)  
DHCP enabled (OFF)  
70  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Installation and operation  
Power  
Contains power management settings  
Power settings (1) (Default values are highlighted):  
Consumption mode (No Consumption Control / Enforced  
Max. Limit / Low Noise Operation / Minimum Power Cons. /  
Scheduled Cons. Mode)  
PSU control enabled  
PSU redundancy (No Redundancy / PSU Redundancy /  
Phase Redundancy)  
PSU Dynamic Mode enable (ON / OFF)  
Power settings (2):  
Maximum Power Limit (value of "Minimum Power Limit" as  
printed in the same menu)  
Power settings (3):  
PSU/Phase Assignment (Unassigned)  
Phase Limit (no value)  
PIN  
Contains a four-digit PIN as password protection for the  
ServerView Local Service Display for Blade  
Default values:  
PIN enabled (OFF)  
PIN (0000)  
Check  
Ekeying Check: This is a function which allows you to query the  
compatibility of the modules before startup, and then activate,  
partially activate or deactivate the module depending on the  
result. For example, you would not activate modules whose  
operating voltages or power consumption are not compatible with  
the system.  
This test begins automatically after switch-on or after a hardware  
replacement. If errors are found, you can find out more about  
them via the Details button. Replace the defective hardware  
component and repeat the test.  
Save  
Clicking the Save button saves and applies the settings in the  
management blade.  
With the Previous button you can go back and change  
parameters. You save the changed configuration with the Save  
button.  
BX400 S1  
Operating Manual  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and operation  
Export  
Deploy / export settings  
Deploy Settings  
Stored settings can be transferred to another system in the  
rack. In the next menu you can specify which configuration  
data you want to copy onto which other systems in the  
rack.  
Export Settings  
Stored settings can be saved on a USB storage medium.  
In the next menu you can specify which configuration data  
you want to save to the USB storage medium.  
72  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Installation and operation  
5.4  
Cleaning the system unit  
V
CAUTION!  
To clean the system unit, first switch it off and unplug the power plug(s)  
from the grounded power outlet(s).  
The housing interior of the system unit should only be cleaned by  
authorized, qualified personnel.  
Do not use abrasive powder or detergents which dissolve plastic to clean  
the housing exterior.  
Make sure that no liquid gets inside the device and that the ventilation  
slits on the system unit remain open.  
Clean the keyboard and the mouse with a disinfecting cloth.  
You may clean the housing surface of the system unit with a dry cloth. If it is very  
dirty you can use a damp cloth that has been dipped in water with a mild  
detergent and well wrung out.  
BX400 S1  
Operating Manual  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation and operation  
74  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
6
Property and data protection  
The blade server is protected against unauthorized access by the lockable rack  
door.  
To protect the system and data internally against unauthorized access, you can  
activate the security functions of the management blade. For more information,  
see the manual "PRIMERGY BX400 Blade Server Systems ServerView  
Management Blade S1 User Interface Description".  
Further security options can be set in the BIOS setups and in the operating  
systems of the server blades. For information on these, see the operating  
manuals for the server blades.  
BX400 S1  
Operating Manual  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Property and data protection  
76  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
7
Troubleshooting and tips  
V
CAUTION!  
Follow the safety instructions in the chapter "Important notes" on  
page 25.  
If a fault occurs, try to correct it as described:  
in this chapter,  
in the chapters for the installed components,  
in the documentation for the connected devices,  
in the help systems of the individual programs used.  
If you do not manage to correct the problem, proceed as follows:  
Ê
Make a note of the steps you have taken and the situation in which the fault  
occurred. Also make a note of the error messages displayed.  
Ê
Ê
Switch off the defective server blade or the system.  
Contact customer service.  
7.1  
System power indicator does not light up  
The system's power indicator (see figure 16 on page 61) does not light up after  
you have switched on your system:  
Power cable not connected correctly  
Ê
Make sure that the power cable is correctly connected to the system's power  
supply units and to the socket strip of the rack (see section "Connecting the  
system unit to the mains" on page 51).  
Power supply overloaded  
Ê
Unplug the power cables from the insulated sockets of the power supply  
units.  
Ê
Ê
Wait a few seconds and then plug the power cables back into the sockets.  
Switch on your system.  
BX400 S1  
Operating Manual  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Troubleshooting and tips  
7.2  
Front or back error LED flashes orange  
If the front or back ID/error LED is flashing orange (see section "Control and  
display elements" on page 55), one of the following errors may have occurred:  
One of the power supply units has failed  
The status LED of the power supply unit is not lit and/or the error LED of the  
power supply unit flashes green if, for example, one of the following errors has  
occurred in the power supply unit (see also figure "Indicator on the hot-plug  
power supply unit" on page 64):  
General failure (warning or shutdown due to fan no. 1)  
Temperature exceeded (one of the fans in the power supply unit is not  
working properly)  
Overcurrent  
Overvoltage or undervoltage  
The power supply unit is reaching the end of its life or its ambient thresholds  
are being exceeded.  
Ê
Check the status of the power supply unit and/or the fan-failure LEDs to  
identify the defective module and replace it (see section "Replacing the  
power supply unit" on page 121).  
One of the fans in the fan module has failed  
Although the system can still be used if one of the fans in the fan module fails,  
you should:  
Ê
Replace the defective fan module as soon as possible (see section "Hot-  
plug fan modules" on page 123).  
A switch blade has failed  
The error LED of the switch blade lights up when a general error occurs.  
Ê
Ê
Check the error LEDs of the switch blades to find out which blade has failed.  
If the switch blade is still being shown as defective, replace it (see section  
"Installing a connection blade" on page 112).  
78  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Troubleshooting and tips  
7.3  
System switches itself off  
Server Management has detected an error  
Ê
Check the error list of System Event Log in ServerView Operations Manager  
or in the management blade web interface, and attempt to eliminate the  
error.  
BX400 S1  
Operating Manual  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Troubleshooting and tips  
80  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
8
Hot-plug components  
This chapter explains how to handle the hot-plug components within the  
Customer-Self-Service (CSS) concept and how to make hardware changes to  
your system unit in general (e.g. adding or replacing hot-plug power supply units  
or hot-plug fan modules).  
I
Further information on the CSS concept is provided in the "Customer  
Self Service (CSS)" manual on the ServerView Suite DVD 2.  
Expansions and upgrades may only be carried out by authorized  
specialist personnel. These operations are described in the Options  
Guide.  
BX400 S1  
Operating Manual  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
8.1  
Server blades and storage blades  
/
1
3
5
Figure 20: Numbering of the server blade slots  
The PRIMERGYBX400 S1 system unit has 8 slots on the front for  
server blades. Alternatively, the bays 2, 4, 6 and 8 can be equipped with storage  
blades, which occupy one bay. Alternatively, the bays 2-3 and 6-7 or 4-5 can be  
equipped with the storage blades, which occupy two bays.  
Different models and configurations of server blades can be combined in the  
system unit.  
82  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Hot-plug components  
Installing a server blade  
CAUTION!  
V
Make sure you observe the safety notes and the information on  
handling electrostatic-sensitive devices in the section "Modules with  
Electrostatic-Sensitive Devices" on page 32.  
Beware of the energy hazard at the midplane contacts. A short circuit  
on these contacts may damage the system.  
The server blade boots automatically after installation in the  
system unit.  
When you install a server blade in an active system unit, the server  
blade automatically performs a Power-On Self-Test (POST) and then  
switches itself off.  
If the system unit is switched off when you install the server blade, the  
automatic POST is performed immediately after you switch on the  
system unit.  
Any unused server blade slots must be fitted with dummy modules to  
comply with electromagnetic compatibility (EMC) regulations and to  
ensure sufficient cooling of the system components.  
BX400 S1  
Operating Manual  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
The following describes how to install a BX920 S2 server blade. Storage blades  
are installed in the same way.  
/
1
0
Figure 21: Installing the BX920 S2 server blade  
Ê
Ê
Ê
Undo the locking mechanism of the release lever (1).  
Open the release lever (2).  
Push the server blade as far as possible into the empty slot (3).  
84  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
/
Figure 22: Locking the BX920 S2 server blade  
Ê
Push the release lever up until it clicks into place under the locking lever (1).  
Removal is carried out in reverse order.  
BX400 S1  
Operating Manual  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
Installing a dummy server blade module  
Any unused server blade slots must be fitted with dummy modules to comply  
with EMC regulations for the system and to ensure sufficient cooling of the  
components.  
/
Figure 23: Dummy server blade module  
The handle (1) is movable and acts as a release lever. It must be at the bottom  
when you install the dummy module in the system unit (see figure 24 on  
page 87).  
86  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
/
Figure 24: Installing a dummy server blade module  
Ê
Push the dummy server blade into the empty slot until it clicks into place.  
Removing a dummy server blade module  
Ê
Push up the release lever (1) and pull the dummy module out of the slot by  
its handle.  
BX400 S1  
Operating Manual  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
8.2  
Connection blades  
The PRIMERGY BX400 S1 system unit has 4 slots on the back for connection  
Infinband environments.  
This section deals with the connection blades available for your BX400 S1  
system unit. It describes their most important features, the external ports, the  
assignment of the internal ports to the server blades, and how to install and  
remove connection blades in/from the system unit.  
How to configure and operate the connection blades is explained in separate  
manuals.  
The following connection blades are available:  
Connection Blade GbE Switch/IBP 36/8+2 (SB11)  
Connection Blade GbE Switch/IBP 18/6 (SB6)  
Connection Blade 10 GbE Switch/IBP 18/8  
Connection Blade Ethernet Pass Thru 10Gb 18/18  
Connection Blade 8Gb FC Switch 18/8  
Connection Blade 8Gb FC Pass Thru 18/18  
Connection Blade Infiniband Switch 40 Gb 18/18  
https://globalsp.ts.fujitsu.com/dmsp/docs/cnfgbx400s1.pdf  
(for the EMEA market)  
http://primeserver.fujitsu.com/primergy/system.html  
I (for the Japanese market)  
Please refer to the connection blades manuals for other connection  
blades.  
88  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Hot-plug components  
8.2.1 Connection Blade GbE Switch/IBP 36/12 (SB11A)  
The Connection Blade GbE Switch/IBP 36/12 can be used as a layer-2 switch  
or an Intelligent Blade Panel (IBP). It provides the following connections:  
36 internal 1-Gbit ports to the server blades  
8 external 1-Gbit ports through RJ45 connections  
4 external 1-Gbit ports through SFP modules for Ethernet ports via fiber-  
optic or copper cable  
This connection blade can be used in all connection blade slots, see figure  
"Connection blade slots" on page 108.  
If the connection blade is installed in one of the slots CB 2, CB 3 or CB 4, the  
server blades must have corresponding GbE mezzanine cards. For more  
information, see the operating manuals for the relevant server blades.  
Ports and LEDs  
3 4  
5
6
1
2
A
B
Figure 25: Connection Blade GbE Switch/IBP 36/12  
BX400 S1  
Operating Manual  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
1
2
ID indicator (blue)  
Lit:  
ID LED was activated via the management blade  
Normal operation  
Dark:  
Status indicator (green/orange)  
Lights up green: Power is supplied to the connection blade  
Lights up  
orange:  
Switch error  
Dark:  
Power is not supplied to the connection blade  
A
1-Gbit Ethernet ports for SFP modules for connection of fiber-optic or copper  
cables (each with two integrated status LEDs)  
3 (ERR) Error indicator (orange)  
Dark:  
Lit:  
No SFP transceiver error  
SFP transceiver error  
Flashes:  
SFP module not supported  
4 (LINK) LAN connection indicator (green)  
Lit:  
LAN connection available  
Flashes:  
Dark:  
LAN connection active  
LAN connection unavailable or deactivated  
B
1-Gbit Ethernet ports (RJ45 with two integrated LAN status LEDs each)  
5
LAN transfer rate (green/orange)  
Lights up  
orange:  
LAN transfer rate 1 Gbit/s  
Lights up green: LAN transfer rate 100 Mbit/s  
Dark:  
LAN transfer rate 10 Mbit/s  
6
LAN connection indicator (green)  
Lit:  
LAN connection available  
Flashes:  
Dark:  
LAN connection active  
LAN connection unavailable or deactivated  
90  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
8.2.2 Connection Blade GbE Switch/IBP 36/8+2 (SB11)  
The Connection Blade GbE Switch/IBP 36/8+2 can be used as a layer-2 switch  
or an Intelligent Blade Panel (IBP). It provides the following connections:  
8 external 1-Gbit ports through RJ45 connections  
2 external 10-Gbit ports through SFP+ modules for Ethernet connections via  
fiber-optic or copper cable  
1 internal stacking port to the midplane of the BX400 S1 system unit  
1 external stacking port through a CX4 connection  
The stacking ports allow up to 4 SB11 connection blades to be switched  
together to form a so-called stack, see "Connection blade stacking" on  
page 94.  
This connection blade can be used in all connection blade slots, see figure  
"Connection blade slots" on page 108.  
If the connection blade is installed in one of the slots CB 2, CB 3 or CB 4, the  
server blades must have corresponding GbE mezzanine cards. For more  
information, see the operating manuals for the relevant server blades.  
BX400 S1  
Operating Manual  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
Ports and LEDs  
1
2 3 4 5  
6 7  
8
9
A
B
C
Figure 26: Connection Blade GbE Switch/IBP 36/12  
1
Status indicator (green/orange)  
Lights up green: Power is supplied to the connection blade  
Flashes orange: Connection blade error  
Dark:  
ID indicator (blue)  
Lit:  
Power is not supplied to the connection blade  
2
3
ID LED was activated via the management blade  
Normal operation  
Dark:  
Stacking port 1 (internal) (green)  
Lit:  
Stacking port 1 is available  
Flashes green: Stacking port 1 is active  
Dark:  
Stacking port 1 is not available  
4
5
Stacking port 2 (external) (green)  
Lit:  
Stacking port 2 is available  
Flashes green: Stacking port 2 is active  
Dark:  
Stacking port 2 is not available  
Connection blade is stack master  
Stacking (green/orange)  
Lights up  
yellow:  
Flashes yellow: Connection blade cannot perform role of master  
Lights up green: Connection blade is stack slave  
Flashes green: Master selection process is active  
Dark:  
Connection blade does not belong to a stack  
92  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
A
B
HiGig/HiGig+ connection (CX4) for stacking, see "Connection blade stacking" on  
page 94  
10-Gbit Ethernet ports for SFP+ modules for connecting fiber-optic or copper  
cables (with two integrated status LEDs each)  
6 (ERR) Error indicator (orange)  
Dark:  
Lit:  
No SFP+ transceiver error  
SFP+ transceiver error  
Flashes:  
SFP+ module not supported  
7 (LINK) LAN connection indicator (green)  
Lit:  
SFP+ transceiver connection available  
Flashes:  
Dark:  
SFP+ transceiver connection active  
SFP+ transceiver connection not available or  
deactivated.  
C
1-Gbit Ethernet ports (RJ45 with two integrated LAN status LEDs each)  
5
LAN transfer rate (green/orange)  
Lights up  
orange:  
LAN transfer rate 1 Gbit/s  
Lights up green: LAN transfer rate 100 Mbit/s  
Dark:  
LAN transfer rate 10 Mbit/s  
6
LAN connection indicator (green)  
Lit:  
LAN connection available  
Flashes:  
Dark:  
LAN connection active  
LAN connection unavailable or deactivated  
BX400 S1  
Operating Manual  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
8.2.2.1 Connection blade stacking  
Up to 4 Connection Blades GbE Switch/IBP 36/8+2 can be switched together to  
form a so-called stack. One of the connection blades takes on the role of the  
master. This connection blade is used to administer all modules of the stack. All  
modules of a stack act as one connection blade. In this way, connection blade  
stacking offers a large number of ports with minimum administrative effort.  
The connections within a stack are established through the stacking ports of the  
connection blades. The internal stacking ports to the midplane of the system  
unit are each used to connect two connection blades that are installed in the  
same fabric, i.e. in two adjacent slots. Connection blades in different fabrics are  
connected through the external ports using CX4 cables.  
Figure 27: CX4 cable  
The stacking connections within a stack must form a circuit. Connection blade  
stacks can be formed within a system unit, across several system units of a rack  
or across several system units in different racks.  
Further information  
You determine which connection blade takes on the master role through the  
sequence and the intervals at which the connection blades are booted and  
connected with each other. For more detailed information and additional  
possible configurations, see the manuals "PRIMERGY BX900 Blade Server  
Systems – Ethernet Connection Blade Module IBP Version – User’s Guide",  
"PRIMERGY BX900 Blade Server Systems – Ethernet Connection Blade  
Module Switch Version – User’s Guide" and " スイッチブレー10Gbps 18/8)  
取扱説明書 " (for the Japanese market).  
94  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
Hot-plug components  
8.2.3 Connection Blade GbE Switch/IBP 18/6 (SB6)  
The Connection Blade GbE Switch/IBP 18/6 can be used as a layer-2 switch or  
an Intelligent Blade Panel (IBP). It provides the following connections:  
18 internal 1-Gbit ports to the server blades  
6 external 1-Gbit ports through RJ45 connections  
This connection blade can be used in all connection blade slots, see figure  
"Connection blade slots" on page 108.  
If the connection blade is installed in one of the slots CB 2, CB 3 or CB 4, the  
server blades must have corresponding GbE mezzanine cards. For more  
information, see the operating manuals for the relevant server blades.  
BX400 S1  
Operating Manual  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
Ports and LEDs  
1 2  
3
4
A
Figure 28: Connection Blade GbE Switch/IBP 18/6  
1
Status indicator (green/orange)  
Lights up green: Power is supplied to the connection blade  
Flashes orange: Connection blade failure  
Dark:  
ID indicator (blue)  
Lit:  
Power is not supplied to the connection blade  
2
ID LED was activated via the management blade  
Normal operation  
Dark:  
A
1-Gbit Ethernet ports (RJ45 with two integrated LAN status LEDs each)  
3
LAN transfer rate (green/orange)  
Lights up  
orange:  
LAN transfer rate 1 Gbit/s  
Lights up green: LAN transfer rate 100 Mbit/s  
Dark:  
LAN transfer rate 10 Mbit/s  
4
LAN connection indicator (green)  
Lit:  
LAN connection available  
Flashes:  
Dark:  
LAN connection active  
LAN connection unavailable or deactivated  
96  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
8.2.4 Connection Blade 10 GbE Switch/IBP 18/8  
The Connection Blade 10 GbE Switch/IBP 18/8 can be used as a layer-2+  
switch or an Intelligent Blade Panel (IBP). It provides the following connections:  
18 internal 10-Gbit ports to the server blades  
8 external 10-Gbit ports through SFP+ modules or active twinax cables  
(copper)  
This connection blade can be used in all connection blade slots, see figure  
"Connection blade slots" on page 108.  
If the connection blade is installed in one of the slots CB 2, CB 3 or CB 4, the  
server blades must have corresponding 10 GbE mezzanine cards. For more  
information, see the operating manuals for the relevant server blades and the  
manual "PRIMERGY 10GbE Connection Blade 18/8 User Guide" and " スイッ  
チブレード(10Gbps 18/8)取扱説明書 " (for the Japanese market).  
Ports and LEDs  
1 2 3  
4 5  
A
6
Figure 29: Connection Blade 10 GbE Switch/IBP 18/8  
BX400 S1  
Operating Manual  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
1
Status indicator (green/orange)  
Lit green:  
Power is supplied to the connection blade  
Connection blade error  
Flashes  
alternately  
green/orange:  
Dark:  
Power is not supplied to the connection blade  
2
Stack indicator (green/yellow) (future use)  
Lit yellow:  
Operating as a stack master  
Flashes yellow: Operating failure as a stack master  
Lit green:  
Operating as a stack slave  
Flashes green  
Operating failure as a stack slave or during master  
election process  
Dark:  
No stacking  
3
ID indicator (blue)  
Lit:  
Dark:  
ID LED was activated via the management blade  
Normal operation  
6
Hidden reset button  
A
10-Gbit Ethernet ports for SFP+ modules for connection of fiber-optic cables or  
for active twinax copper cables (each with two integrated status LEDs)  
4 (ERR) Error indicator (orange)  
Dark:  
Lit:  
No SFP+ module error or SFP+ module not installed  
SFP+ module error  
Flashes:  
SFP+ module not supported  
5 (LINK) LAN connection indicator (green)  
Lit:  
LAN connection available  
Flashes:  
Dark:  
LAN connection active  
LAN connection unavailable or deactivated  
98  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
8.2.5 Connection Blade Ethernet Pass Thru 10Gb 18/18  
The Connection Blade Ethernet Pass Thru 10Gb 18/18 provides the following  
connections:  
18 internal ports to the server blades at 10 Gbit/s and 1 Gbit/s link speed  
18 external uplink ports at 10 Gbit/s and 1 Gbit/s link speed through  
SFP+/SFP modules  
This connection blade can be used in all connection blade slots, see figure  
"Connection blade slots" on page 108.  
Ports and LEDs  
1 2  
3
A
A
Figure 30: Connection Blade Ethernet Pass Thru 10Gb 18/18  
BX400 S1  
Operating Manual  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
1
ID indicator (blue)  
Lit:  
ID LED was activated via the management blade  
2
Status indicator (green/orange)  
Lit green:  
Flashes orange:  
Dark:  
Power is supplied to the connection blade  
Connection blade error  
Power is not supplied to the connection blade  
3
Status indicators for Ethernet ports (green/orange)  
Dark:  
Occurs in the following cases:  
Server blade not present, powered down, or link is inactive  
Uplink port module not present  
Uplink port cable not connected  
One or both of the internal and/or external links is down  
Lit green:  
Both the internal and external links are up  
Occurs in the following cases:  
Flashes orange:  
Link protocol mismatch (one indicator flashes orange)  
Internal port speed configuration error (all indicators of all  
ports in a port group flash together, see "Port assignment" on  
page 101)  
Flashes green:  
Link is up and data transfer  
A
External ports (18x)  
Ports for Ethernet through SFP/SFP+ modules  
100  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
Port assignment  
If the connection blade is installed in one of the slots CB 1 or CB 2, 16 ports are  
available. Connection blade ports 17 and 18 are not used. The figure below  
shows the port assignment.  
Server blade slots  
5
13  
7
6
14  
8
7
15  
9
8
16  
10  
2
17  
11  
3
18  
12  
4
Connection blade  
ports  
1
1
2
2
3
3
4
4
5
5
6
6
Server blade slots  
7
8
1
If the connection blade is installed in one of the slots CB 3 or CB 4, 8 ports are  
available. Connection blade ports 9 - 18 are not used. The figure below shows  
the port assignment.  
13  
7
14  
8
15  
9
16  
10  
17  
11  
18  
12  
Connection blade  
ports  
1
1
2
2
3
3
4
4
5
5
6
6
Server blade slots  
7
8
The 18 connection blade ports are divided into 6 groups, color indicated in the  
figures above. All the ports within a single group must use the same link protocol  
with eiter 10 Gbit/s or 1 Gbit/s link speed. Default link speed is 10 Gbit/s.  
The configuration of the connection blade is controlled by the management  
blade. Each port group an be configured to a certain link protocol. The  
management blade web interface allows the user to modify the port group link  
speed configuration.  
BX400 S1  
Operating Manual  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
8.2.6 Connection Blade 8Gb FC Switch 18/8  
The 8-Gb FC Switch Connection Blade 18/8 14 (Brocade BR5450) provides the  
following connections:  
18 internal 8-Gbit ports to the server blades  
8 external Fibre Channel ports via 4-Gbit SFP or 8-Gbit SFP+ modules  
This connection blade can be used in slots CB 2, CB 3 and CB 4, see figure  
"Connection blade slots" on page 108. It only supports server blades that are  
fitted with a Fibre Channel mezzanine card. For more information, see the  
operating manuals for the relevant server blades.  
This connection blade is available in three license variants:  
Brocade 5450 with 14-port license  
Brocade 5450 with 26-port license (applies only to EMEA market)  
Brocade 5450 with 26-port license and performance bundle (applies only to  
EMEA market)  
As the operating system for the 8 Gb FC Switch Connection Blade 18/8, the  
complete functional scope of Brocade Fabric OS, the shared software platform for  
Brocade Fibre Channel switches, is available. The FC switch blade is  
administered via Fabric Watch and Advanced Web Tools from Brocade.  
Ports and LEDs  
B
1 2 3  
4
A
C
Figure 31: 8-Gb FC Switch Connection Blade 18/8  
1
ID indicator (blue)  
ID  
Lit:  
ID LED was activated via the management blade  
102  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Hot-plug components  
2
Health indicator (green/yellow) (controlled by management blade)  
Dark:  
Boot phase; connection blade was still not recognized by MMB  
Connection blade is running  
Lights up green:  
Lights up yellow:  
Hidden reset button  
Hardware/functional error or overheating  
3
4
Status indicator (green/orange)  
Dark:  
Connection blade is not running or is defective  
Lights up green:  
Lights up orange:  
Connection blade is running  
Boot phase; one or more ports are offline; restarting connection  
Warning: An error has occurred.  
Flashes  
orange/green:  
The LED can also flash during a test.  
A
B
External FC ports (8x)  
Ports for FC SFP Multi-Mode (MMF) or FC SFP+ Multi-Mode (MMF) SFP modules  
Status indicators for external FC ports (green/orange)  
Dark:  
No signal reception  
Flickers green:  
Flashes green:  
FC port online, data transport  
Slow: FC port online, but segmented  
Fast: Internal loop  
Lights up orange:  
Flashes orange:  
Signal reception, but not online  
Slow (~ 2 sec. interval): FC port deactivated.  
Fast (~ 0.5 sec. interval): FC port defective  
C
Management LAN port  
BX400 S1  
Operating Manual  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
8.2.7 Connection Blade 8Gb FC Pass Thru 18/18  
The 8-Gb FC Pass Thru Connection Blade 18/18 provides the following  
connections:  
18 internal 8-Gbit ports to the server blades  
18 external Fibre Channel ports via 4-Gbit SFP or 8-Gbit SFP+ modules  
This connection blade can be used in slots CB 2, CB 3 and CB 4, see figure  
"Connection blade slots" on page 108. It only supports server blades that are  
fitted with a Fibre Channel mezzanine card. For more information, see the  
operating manuals for the relevant server blades.  
Ports and LEDs  
1 2  
3
B
A
Figure 32: 8-Gb FC Pass Thru Connection Blade 18/18  
1
ID indicator (blue)  
ID  
Lit:  
ID LED was activated via the management blade  
2
Status indicator (green/orange)  
Dark:  
Connection blade is powered off  
Lights up green:  
Flashes orange:  
Connection blade is powered on, status OK  
Connection blade is powered on, status fail  
3
Status indicators for external FC ports (green)  
Lit: FC link up  
A, B External FC ports (A: 1-12, B: 13-18, from left to right)  
Ports for FC SFP Multi-Mode (MMF) 4Gbit/s or FC SFP+ Multi-Mode (MMF) 8Gbit/s  
104  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Hot-plug components  
Port assignment  
Each of the 8 server blades of a BX400 S1 system unit can be equipped with 2  
FC mezzanine cards each with 2 ports (0, 1). Each of the server blade FC ports  
is connected to a dedicated port of an FC pass thru connection blade in a  
defined connection blade slot. The table below shows the port assignment of  
mezzanine card ports and connection blade slots.  
Mezzanine card 1  
Mezzanine card 2  
Server blade slot  
Port 0  
Port 1  
Port 0  
Port 1  
1
2
3
4
5
6
7
8
CB2 port 1  
CB2 port 2  
CB2 port 3  
CB2 port 4  
CB2 port 5  
CB2 port 6  
CB2 port 7  
CB2 port 8  
CB2 port 9  
CB2 port 10  
CB2 port 11  
CB2 port 12  
CB2 port 13  
CB2 port 14  
CB2 port 15  
CB2 port 16  
CB3 port 1  
CB3 port 2  
CB3 port 3  
CB3 port 4  
CB3 port 5  
CB3 port 6  
CB3 port 7  
CB3 port 8  
CB4 port 1  
CB4 port 2  
CB4 port 3  
CB4 port 4  
CB4 port 5  
CB4 port 6  
CB4 port 7  
CB4 port 8  
Example  
Mezzanine card 1 port 0 of server blade in slot 6 is connected to port 6 of FC  
pass thru connection blade in slot 2 (CB2).  
Port 0 of mezzanine card 1 is connected to port 7 of FC pass thru connection  
blade in slot 3.  
For information about port assignment of mezzanine cards and connection  
blade slots please refer also to "Fitting rules for connection blades" on page 108  
and "Port assignment of the connection blades" on page 110  
BX400 S1  
Operating Manual  
105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
8.2.8 Connection Blade Infiniband Switch 40 Gb 18/18  
The Connection Blade Infiniband Switch 40Gb 18/18 provides the following  
connections:  
18 internal 40-Gbit Infiniband ports to the server blades  
18 external 40-Gbit Infiniband connections through QSFP modules  
This connection blade can be used in slots CB 3/4 see figure "Connection blade  
slots" on page 108. It only supports server blades that are fitted with an  
Infiniband mezzanine card. For more information, see the operating manuals for  
the relevant server blades.  
106  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Hot-plug components  
Ports and LEDs  
3 4  
2
1
A
Figure 33: Connection Blade Infiniband Switch 40 Gb 18/18  
1
Status indicator (green/yellow)  
Lights up green:  
Flashes yellow:  
ID indicator (blue)  
Lit:  
Power supply active  
Switch error  
2
ID  
ID LED was activated via the management blade  
3
Physical link status indicator of the external IB ports (green)  
P
Dark:  
No signal reception (IB port offline)  
IB port online  
Lights up green:  
4L/ Logical link status indicator of the external IB ports (yellow)  
A
Dark:  
No signal reception  
IB port online  
Lights up yellow:  
Flashes yellow:  
Data transport  
A
External IB ports (18x)Ports for QSFP plugs  
BX400 S1  
Operating Manual  
107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
8.2.9 Fitting rules for connection blades  
The connection blade slots of the BX400 S1 system unit are numbered as  
follows.  
CB 1 (Fabric 1)  
CB 3 (Fabric 3)  
CB 2 (Fabric 2)  
CB 4 (Fabric 3)  
Figure 34: Connection blade slots  
The connection blade slots are connected to a so-called fabric. The following  
table shows how you can fill the fabrics and which network components of the  
server blades they are connected to:  
Server blade  
Midplane  
Connection blade slots  
CB1:  
CB2:  
Onboard LAN  
Fabric 1  
1 or 10 Gb Ethernet  
Mezzanine  
card slot 1  
Fabric 2  
Fabric 3  
1 or 10 Gb Ethernet or Fibre Channel  
1 or 10 Gb Ethernet or Fibre Channel  
1 or 10 Gb Ethernet or Fibre Channel  
CB3:  
CB4:  
Mezzanine  
card slot 2  
or Infinband  
Table 4: Fitting rules for connection blade slots  
I
Connection blades within one fabric must have the same technology, i.e.  
either Ethernet or Fibre Channel or Infiniband.  
When filling the slots in fabrics 2 and 3, also make sure the server blades are  
fitted with the appropriate mezzanine cards. The following rules apply for fitting  
the mezzanine card slots of the server blades:  
If a 1 Gb Ethernet mezzanine card is installed in slot 1 of a server blade, at  
least one 1 Gb Ethernet connection blade must be installed in CB slot 2 of  
the system unit.  
108  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
     
Hot-plug components  
If a 10 Gb Ethernet mezzanine card is installed in slot 1 of a server blade, at  
least one 10 Gb Ethernet connection blade must be installed in CB slot 2 of  
the system unit.  
If an FC mezzanine card is installed in slot 1, at least one FC connection  
blade must be installed in CB slot 2.  
If a 1 Gb Ethernet mezzanine card is installed in slot 2 of a server blade, at  
least one 1 Gb Ethernet connection blade must be installed in CB slot 3 or  
in CB slot 4 of the system unit.  
If a 10 Gb Ethernet mezzanine card is installed in slot 2 of a server blade, at  
least one 1 Gb Ethernet connection blade must be installed in CB slot 3 or  
in CB slot 4 of the system unit.  
If an FC mezzanine card is installed in slot 2, at least one FC connection  
blade must be installed in CB slot 3 or in CB slot 4.  
If an Infiniband mezzanine card is installed in slot 2, an Infiniband connection  
blade should be installed in CB slots 3 and 4.  
I
In this case, both channels of the Infiniband mezzanine card are  
used.  
You can install a combination of FC, Ethernet and Infiniband mezzanine  
cards in a server blade. In this case, the Ethernet mezzanine card should be  
installed in slot 1 and the FC or Infiniband mezzanine card in slot 2 of the  
server blade.  
BX400 S1  
Operating Manual  
109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
8.2.10 Port assignment of the connection blades  
The A-channels of the controllers in the server blades are connected to the  
connection blade slots on the left-hand side (CB1 and CB3). The B-channels  
are connected to the slots on the right-hand side (CB2 and CB4).  
With the mezzanine cards, the assignment of the ports to the connection blade  
slots can be defined via the management blade. The following figure shows the  
different options.  
mezzanine card  
Server blade slot (x)  
Mezzanine card slot (M)  
Port (P)  
Connection blade slot (CB)  
Port (P)  
Server blade slot (x)  
CB2.P1+(x-1)  
CB2.P9+(x-1)  
CB3.P1+(x-1)  
CB4.P1+(x-1)  
CB2.P1+2*(x-1)  
CB2.P17+2*(x-1)  
CB2.P2+2*(x-1)  
CB2.P18+2*(x-1)  
CB3.P1+2*(x-1)  
CB4.P1+2*(x-1)  
CB3.P2+2*(x-1)  
CB4.P2+2*(x-1)  
CB2.P1+(x-1)  
CB2.P9+(x-1)  
-
x.M1.P1  
x.M1.P2  
FC 8 Gb/s  
x.M2.P1  
x.M2.P2  
x.M1.P1  
x.M1.P2  
x.M1.P3  
x.M1.P4  
LAN 1 GbE (SB11, SB11A)  
x.M2.P1  
x.M2.P2  
x.M2.P3  
x.M2.P4  
x.M1.P1  
x.M1.P2  
x.M1.P3  
x.M1.P4  
-
LAN 1 GbE (SB6)  
x.M2.P1  
CB3.P1+(x-1)  
CB4.P1+(x-1)  
-
x.M2.P2  
x.M2.P3  
x.M2.P4  
-
Table 5: Port assignment of connection blades and mezzanine cards  
110  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
Hot-plug components  
mezzanine card  
Server blade slot (x)  
Mezzanine card slot (M)  
Port (P)  
Connection blade slot (CB)  
Port (P)  
Server blade slot (x)  
CB2.P1+(x-1)  
x.M1.P1  
x.M1.P2  
CB2.P8+(x-1)  
LAN 10 GbE  
Infiniband  
x.M2.P1  
CB3.P1+(x-1)  
x.M2.P2  
CB4.P2+(x-1)  
x.M2.P2  
CB3/CB4+(x-1)  
Table 5: Port assignment of connection blades and mezzanine cards  
For more information on configuring the connection blades, see the manual  
"PRIMERGY BX400 Blade Server Systems ServerView Management Blade S1  
User Interface Description" and the documentation for the relevant connection  
blades.  
BX400 S1  
Operating Manual  
111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
8.2.11 Installing a connection blade  
V
CAUTION!  
Note the safety instructions and the information on handling  
electrostatically sensitive devices in section "Safety instructions" on  
page 25.  
Removing dummy module(s)  
Any unused connection blade slots are fitted with appropriate dummy modules  
to comply with electromagnetic compatibility (EMC) regulations and to ensure  
sufficient cooling of the system components.  
Figure 35: Dummy connection blade module  
To add connection blades, you must first remove the dummy modules from the  
relevant slots.  
112  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
       
Hot-plug components  
Figure 36: Removing a dummy connection blade module  
Ê
Press the handles of the dummy module inward and pull it out of the slot.  
Installation is carried out in the reverse order.  
I
Keep the dummy modules for future use. If you remove a  
connection blade and do not replace it with a new one, you must install  
a dummy module in the empty slot.  
BX400 S1  
Operating Manual  
113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
Installing a single-width connection blade  
V
CAUTION!  
Make sure you observe the safety notes and the information on handling  
electrostatic-sensitive devices in the section "Modules with Electrostatic-  
Sensitive Devices" on page 32.  
Ê
Unpack the connection blade.  
/
Figure 37: Installing a connection blade  
Ê
Open the release lever (1) of the connection blade and push it carefully into  
the empty slot.  
114  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
 
Hot-plug components  
Figure 38: Locking the connection blade  
Ê
Ê
Push the connection blade into the slot as far as it will go.  
Push the release lever in the direction of the arrow until it clicks into place.  
BX400 S1  
Operating Manual  
115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot-plug components  
Installing a double-width connection blade (Infiniband)  
V
CAUTION!  
Make sure you observe the safety notes and the information on handling  
electrostatic-sensitive devices in the section "Modules with Electrostatic-  
Sensitive Devices" on page 32.  
Ê
Unpack the Infiniband connection blade.  
/
0
Figure 39: Removing the separating clip  
I
Because of the double width of these connection blades, you must  
remove the separating clip between the two slots of fabric 3 before you  
install the connection blade.  
Ê
Remove the separating clip by pressing the little black lever (1) to the left and  
pulling out the separating clip (2).  
116  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
Hot-plug components  
/
0
Figure 40: Installing a double-width connection blade  
Ê
Ê
Open the release lever of the connection blade and push it carefully into the  
empty fabric as far as it will go (1).  
Push the release lever in the direction of the arrow (2) until it clicks into  
place.  
Removal is carried out in reverse order.  
V
CAUTION!  
If you remove a double-width connection blade and do not replace it with  
a new one, you must install the separating clip (see page 116) and two  
dummy modules in the empty slot, see page 112.  
BX400 S1  
Operating Manual  
117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
8.3  
Management blades  
Figure 41: management blade  
The PRIMERGY BX400 S1 system unit has slots for two redundant, hot-swap  
management blades with an integrated management solution for complete  
remote administration of the system. The basic configuration of the BX400 S1  
system unit contains one management blade.  
The management blades offer user-friendly user interfaces: a Web interface  
and a console menu interface via Telnet protocol. For a detailed description, see  
the manual "PRIMERGY BX400 Blade Server Systems ServerView  
Management Blade S1 User Interface Description".  
The slots for the management blades are located on the back of the system unit  
(see figure 8 on page 49).  
A management blade is installed and removed in the same way as a connection  
blade (see "Installing a connection blade" on page 112).  
V
CAUTION!  
After installing the management blade, it is necessary to update the  
management blade firmware. Use for the update the management blade  
web interface, see "PRIMERGY BX400 Blade Server Systems  
ServerView Management Blade S1 User Interface Description".  
When two management blades are installed, make sure that both  
management blades (master/slave) have the same firmware version.  
118  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
   
Hot-plug components  
8.4  
Hot-plug power supply units  
The BX400 S1 system unit has 4 bays for hot-plug power supply units (PSU  
1-4). The power supply units adapt automatically to any voltage within the range  
100 V - 127 V / 200 V - 240 V.  
All bays for power supply units are fitted with flaps which close automatically.  
This ensures sufficient cooling of the system components when you replace a  
power supply unit or fan module during operation.  
The PSU bays must be fitted according to their numbering. Unoccupied PSU  
bays must be fitted with fan modules to ensure that the system components are  
properly cooled, see "Hot-plug fan modules" on page 123.  
PSU 1  
PSU 2  
PSU 3  
PSU 4  
Figure 42: Numbering of the power supply unit bays  
In the minimum configuration, the BX400 S1 system unit contains one hot swap  
power supply unit (PSU1). This enables a fully populated BX400 S1 system unit  
to run in low power mode. Full power mode requires at least two PSUs in 200  
V environments or three PSUs in 100 V environments.  
To provide a redundant power supply, a third or fourth power supply unit can be  
installed (PSU3 and PSU4) in 200 V environments. In 100 V environments a  
fourth power supply unit (PSU4) is required to provide a redundant power  
supply. If one of the four power supply units fails, the other two/three units will  
ensure the system unit continues to operate normally. The defective power  
supply unit can be replaced while the system unit is still running (hot swap).  
BX400 S1  
Operating Manual  
119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
V
CAUTION!  
If a power supply unit fails in a non-redundant configuration of power  
supply units, and the remaining power supply units do not provide  
I sufficient power, the system unit is shut down immediately.  
Make sure that the individual power supply units are connected to  
different AC sources. This ensures additional AC source redundancy for  
high-availability configurations. If only one AC source fails, the power  
supply units connected to the other AC sources remain operational.  
For detailed information about power management please refer the manual  
"PRIMERGY BX400 Blade Server Systems ServerView Management Blade S1  
User Interface Description".  
120  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
8.4.1 Replacing the power supply unit  
If a power supply unit fails, an error message is output on the LocalView display.  
The defective power supply unit can be replaced during operation.  
V
CAUTION!  
CAUTION! The power supply unit can be very hot!  
Ê
Ê
Ê
Check the power supply unit LEDs on the back of the system unit (see  
figure 17 on page 64) to find out which unit is defective.  
First unplug the power cable of the defective power supply unit from the  
mains.  
Unplug the power cable from the insulated socket of the defective power  
supply unit.  
0
/
Figure 43: Open release lever  
Ê
Unlock the locking lever (1) and open the release lever (2).  
BX400 S1  
Operating Manual  
121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Hot-plug components  
Figure 44: Removing the power supply unit  
Ê
Pull the power supply unit out of its bay.  
Installation is carried out in the reverse order.  
122  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Hot-plug components  
8.5  
Hot-plug fan modules  
The PSU bays of the BX400 S1 system unit can alternatively be fitted with hot-  
plug fan modules.  
Figure 45: Fan module  
I
The unoccupied PSU bays must be fitted with fan modules to ensure that  
the system components are properly cooled.  
Fan modules are removed and installed in the same way as power supply units,  
see "Replacing the power supply unit" on page 121.  
BX400 S1  
Operating Manual  
123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
124  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Index  
connection blades  
fitting rules 108  
consumables 35  
control elements  
system 55  
3rd party rack  
requirements 41  
A
acclimatization time 37  
add  
cooling  
server blade 83  
ambient conditions 22  
ASR&R 17  
fan in power supply unit 17  
fan module 17  
CSS indicator 59, 62  
availability 17  
B
data manipulation 11  
DataCenter rack  
display elements  
connection blade 112  
BIOS update 18  
C
cable  
connect 54  
disconnect 54  
cable strain relief 53  
cable tie 53  
cabling 51  
CE marking 20, 33  
certification  
product safety 21  
clean  
keyboard 73  
mouse 73  
screen 73  
E
electromagnetic compatibility 20, 33  
(ESD) 32  
EMC directive 20  
environment class 22  
environmental protection 35  
error  
server 73  
components  
hardware 11  
hot-swap 17  
software 11  
connect  
cable 54  
system switches itself off 79  
external devices  
external devices 54  
connection blade  
dummy module 112  
install 112, 114  
stacking 94  
connect 54  
BX400 S1  
Operating Manual  
125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
F
fan  
install  
connection blade 112, 114  
indicator 65  
fan module  
back 17  
in rack 40  
Infiniband connection blade 116  
front 17  
flash EPROM 18  
L
G
Global Error indicator 59, 62  
LAN transfer rate, indicator 63  
laser information 30  
system power indicator does not  
H
hard disk module  
acclimatization time 37  
hot-plug power supply unit 16  
hot-swap  
fan module 17  
management blade 17  
power supply unit 17  
server blade 17  
switch-blade 17  
Low Voltage Directive 20, 33  
M
mains  
I
ID button 58, 62  
ID card  
product name 38  
serial number 38  
ID indicator 59  
indicator  
on fans 65  
power supply unit 64  
indicators  
noise level 22  
On/Off button 58  
CSS 59, 62  
P
Global Error 59, 62  
LAN activity 63  
LAN transfer rate 63  
system error 59, 62  
Infiniband connection blade  
features 16  
install 116  
remove 117  
information  
packaging 35, 38  
PDA 17  
power on indicator 58  
power supply  
power supply unit 16  
power supply unit 16  
cable strain relief 53  
cable tie 53  
indicators 64  
replace 121  
further sources 12  
126  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Index  
power supply, redundant 16  
PRIMECENTER Rack  
requirements 40  
server blade  
PRIMERGY diagnostic LED 18  
product name 38  
property protection 75  
ServerView Operations Manager 17  
supported functions 17  
ServerView Remote  
Management 18  
R
rack  
PRIMERGY diagnostic LED 18  
requirements 40  
recycling devices 36  
redundancy  
power supply 16  
regulations and standards 20  
reliability 17  
setting up, server 39  
system 66  
switching on  
remove  
Infiniband connection blade 117  
replace  
power supply unit 121  
requirements  
3rd party rack 41  
DataCenter rack 40  
PRIMECENTER Rack 40  
return of devices 36  
display elements 55  
switches itself off (error) 79  
PRIMERGY diagnostic LED 18  
S
Safety instructions 25  
safety standards 20  
saving energy 35  
security function 11  
serial number 38  
server  
data protection 75  
dimensions 21  
electrical data 20  
noise level 22  
power on indicator 58  
product name 38  
property protection 75  
serial number 38  
service 18  
target group 11  
Technical data 20  
technical data 20  
ambient conditions 22  
touch point 18  
transport damage 38  
U
setting up 39  
unpacking, server 38  
transport 33  
unpacking 38  
BX400 S1  
Operating Manual  
127  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
128  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  
Index  
BX400 S1  
Operating Manual  
129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
130  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaBdX.400 S1  

Edelbrock Automobile Parts 1797 User Manual
Ei Electronics Smoke Alarm EI161R User Manual
Electro Voice Portable Speaker MTH 2 94B User Manual
Euro Pro Blower EP366 User Manual
Fagor America Electric Pressure Cooker 918010051 User Manual
Fisher Price Baby Toy V5611 User Manual
Fostex Music Pedal FE208 User Manual
GE Dishwasher GDF510 540 Series User Manual
Gitzo Camcorder Accessories G1312 User Manual
Goodman Mfg Heat Pump GPH14H User Manual