Frymaster Fryer 8195991 User Manual

Frymaster, a member of the Commercial Food Equipment Service Association, recommends  
using CFESA Certified Technicians.  
SEPTEMBER 2005  
24-Hour Service Hotline 1-800-551-8633  
* 8 1 9 5 9 9 1 *  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
No structural material on the fryer should be altered or removed to accommodate placement of  
the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.  
DANGER  
Adequate means must be provided to limit the movement of this appliance without depending  
upon the gas line connection. Single fryers equipped with legs must be stabilized by installing  
anchor straps. All fryers equipped with casters must be stabilized by installing restraining  
chains. If a flexible gas line is used, an additional restraining cable must be connected at all  
times when the fryer is in use.  
DANGER  
The front ledge of the fryer is not a step! Do not stand on the fryer. Serious injury can result  
from slips or contact with the hot oil.  
DANGER  
Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any  
other appliance.  
DANGER  
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak  
must be posted in a prominent location. This information can be obtained from the local gas  
company or gas supplier.  
DANGER  
This product contains chemicals known to the state of California to cause cancer and/or birth  
defects or other reproductive harm.  
Operation, installation, and servicing of this product could expose you to airborne particles of  
glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne  
particles of glasswool or ceramic fibers is known to the State of California to cause cancer.  
Inhalation of carbon monoxide is known to the State of California to cause birth defects or other  
reproductive harm.  
DANGER  
The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container  
at the end of frying operations each day. Some food particles can spontaneously combust if left  
soaking in certain shortening material.  
WARNING  
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal  
the joint between the fry vessels. Banging fry baskets on the strip to dislodge shortening will  
distort the strip, adversely affecting its fit. It is designed for a tight fit and should only be  
removed for cleaning.  
NOTICE  
The Commonwealth of Massachusetts requires any and all gas products to be installed by a  
licensed plumber or pipe fitter.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO H55 SERIES GAS FRYER  
INSTALLATION & OPERATION MANUAL  
TABLE OF CONTENTS  
CHAPTER 1: General Information  
1.1 Applicability and Validity................................................................................................. 1-1  
1.2 Parts Ordering and Service Information............................................................................ 1-1  
1.3 Safety Information............................................................................................................. 1-2  
1.4 European Community (CE) Specific Information............................................................. 1-2  
1.5 Equipment Description...................................................................................................... 1-3  
1.6 Installation, Operating, and Service Personnel ................................................................. 1-3  
1.7 Definitions......................................................................................................................... 1-3  
1.8 Shipping Damage Claim Procedure .................................................................................. 1-4  
CHAPTER 2: Installation Instructions  
2.1 General Installation Requirements .................................................................................... 2-1  
2.2 Caster/Leg Installation ...................................................................................................... 2-3  
2.3 Pre-Connection Preparations............................................................................................. 2-3  
2.4 Connection to Gas Line..................................................................................................... 2-5  
2.5 Converting to Another Gas Type ...................................................................................... 2-8  
CHAPTER 3: Operating Instructions  
3.1 Controller Operation and Programming............................................................................ 3-1  
3.2 Start-Up Procedure............................................................................................................ 3-1  
3.3 Boiling Out the Frypot ...................................................................................................... 3-3  
3.4 Shutting the Fryer Down ................................................................................................... 3-3  
CHAPTER 4: Filtration Instructions  
4.1 Draining and Manual Filtering.......................................................................................... 4-1  
4.2 Preparing the Built-In Filtration System for Use .............................................................. 4-2  
4.3 Operation of the Filter ....................................................................................................... 4-5  
4.4 Disassembly and Reassembly of the Magnasol Filter....................................................... 4-8  
4.5 Draining and Disposing of Waste Oil ............................................................................... 4-9  
4.6 Using the Optional Rear-Discharge Oil Disposal ........................................................... 4-10  
CHAPTER 5: Preventive Maintenance  
5.1 Fryer Preventive Maintenance Checks and Service.......................................................... 5-1  
Daily Checks and Service.................................................................................................. 5-1  
Weekly Checks and Service.............................................................................................. 5-1  
Monthly Checks and Service............................................................................................. 5-3  
Quarterly Checks and Service ........................................................................................... 5-4  
Semi-Annual Checks and Service ..................................................................................... 5-6  
5.2 Built-In Filtration System Preventive Maintenance Checks and Service ......................... 5-6  
5.3 Annual/Periodic System Inspection .................................................................................. 5-7  
CHAPTER 6: Operator Troubleshooting  
6.1 Introduction ....................................................................................................................... 6-1  
6.2 Troubleshooting Fryers with Computer Magic III.5, Basket Lift Timer, or Digital  
Controller........................................................................................................................... 6-2  
6.3 Troubleshooting Fryers with Solid State (Analog) Controller.......................................... 6-4  
6.4 Troubleshooting the Built-In Filtration System ................................................................ 6-6  
6.5 Troubleshooting the Basket Lift........................................................................................ 6-8  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THIS PAGE INTENTIONALLY LEFT BLANK  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO H55 SERIES GAS FRYER  
CHAPTER 1: GENERAL INFORMATION  
1.1  
Applicability and Validity  
The Pro H55 Series Gas Fryer has been approved by the European Union for sale and installa-  
tion in the following EU countries: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT  
and SE.  
This manual is applicable to and valid for all Pro H55 Series Gas Fryers sold in English-  
speaking countries, including those in the European Union. Where conflicts exist between in-  
structions and information in this manual and local or national codes of the country in which  
the equipment is installed, installation and operation shall comply with those codes.  
This appliance is only for professional use and shall be used by qualified personnel only, as  
defined in Section 1.7.  
1.2  
Parts Ordering and Service Information  
In order to assist you quickly, the Frymaster Factory Authorized Service Center (FASC) or Service  
Department representative requires certain information about your equipment. Most of this  
information is printed on a data plate affixed to the inside of the fryer door. Part numbers are found  
in the Installation, Operation, Service, and Parts Manual. Parts orders may be placed directly with  
your local FASC or distributor. Included with fryers when shipped from the factory is a list of  
Frymaster FASCs. If you do not have access to this list, contact the Frymaster Service Department  
at 1-800-551-8633 or 1-318-865-1711 or by e-mail: [email protected].  
When ordering parts, the following information is required:  
Model Number:  
Serial Number:  
Type of Gas or Voltage:  
Item Part Number:  
Quantity Needed:  
Service information may be obtained by contacting your local FASC/Distributor. Service may also  
be obtained by calling the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711 or  
by e-mail: [email protected]. When requesting service, please have the following information  
ready:  
Model Number:  
Serial Number:  
Type of Gas:  
In addition to the model number, serial number, and type of gas, please be prepared to describe the  
nature of the problem and have ready any other information that you think may be helpful in solving  
your problem.  
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.3  
Safety Information  
Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout  
this manual, you will find notations enclosed in double-bordered boxes similar to the ones that  
follow.  
CAUTION  
CAUTION boxes contain information about actions or conditions that may cause or result  
in a malfunction of your system.  
WARNING  
WARNING boxes contain information about actions or conditions that may cause or result  
in damage to your system, and which may cause your system to malfunction.  
DANGER  
DANGER boxes contain information about actions or conditions that may cause or result  
in injury to personnel, and which may cause damage to your system and/or cause your  
system to malfunction.  
Your fryer is equipped with automatic safety features:  
1. High temperature detection shuts off gas to the burner assembly should the controlling  
thermostat fail.  
2. An optional safety switch built into the drain valve prevents burner ignition with the drain valve  
even partially open.  
1.4  
European Community (CE) Specific Information  
The European Community (CE) has established certain specific standards regarding equipment of  
this type. Whenever a conflict exists between CE and non-CE standards, the information or  
instructions concerned are identified by means of shadowed boxes similar to the one below.  
Non-CE Standard  
for Incoming Gas Pressures  
Type  
Minimum Maximum  
6" W.C.  
14" W.C.  
3.49 kPa  
Natural  
1.49 kPa  
14.68 mbar 34.72 mbar  
11" W.C.  
2.74 kPa  
14" W.C.  
3.49 kPa  
LP  
27.28 mbar 34.84 mbar  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.5  
Equipment Description  
Pro H55 Series high-efficiency gas fryers employ a unique infrared burner system that uses up to  
43% less energy to cook the same volume as conventional open-burner fryers. Models in this series  
include PH55, FMPH55, and FPPH55 variants. PH55 models have no built-in filtration system.  
FPPH55 models have a built-in FootPrint Pro filtration system located under the leftmost two fryers  
in a battery. FMPH55 models also have a built-in FootPrint Pro filtration system under the leftmost  
two stations of a battery. The difference between FPPH55s and FMPH55s is that FPPH55s have no  
holding stations (i.e., the battery consists only of fryers) while the FMPH55s have a holding station  
at one of the positions in the battery. For example, an FPPH355 consists of three fryers with built-in  
filtration; an FMH355, by comparison, consists of two fryers and one holding station with built-in  
filtration. A PH355 consists of three fryers without built-in filtration.  
All Pro H55 Series Gas fryers are of an open-frypot design with no tubes and have a hand-sized  
opening into the deep cold zone, which makes cleaning the stainless frypot quick and easy.  
Heating is supplied by a pair of infrared burner assemblies mounted on each side of the frypot.  
Combustion air for the burners is supplied by a dedicated blower mounted on the front of the frypot.  
Pro H55 Series Gas fryers can be configured for natural gas, propane (LP), or manufactured gas, as  
required by the customer.  
Each frypot is equipped with a temperature probe for precise temperature control.  
All Pro H55 Series Gas fryers come standard with electronic ignition, melt cycle and boil-out mode.  
Control options include Computer Magic III.5 computers, solid-state (analog) controllers, digital  
controllers, and basket lift timers.  
All fryers in this series require an external source of AC electrical power. Units can be configured  
for voltages ranging from 100 VAC to 240 VAC.  
FMPH55 and FPPH55 fryers are shipped completely assembled. PH55 fryers may require  
installation of legs or optional casters at the point of use. All fryers are shipped with a package of  
standard accessories. Each fryer is adjusted, tested, and inspected at the factory before crating for  
shipment.  
1.6  
Installation, Operating, and Service Personnel  
Operating information for Frymaster equipment has been prepared for use by qualified and/or  
authorized personnel only, as defined in Section 1.7. All installation and service on Frymaster  
equipment must be performed by qualified, certified, licensed, and/or authorized installation  
or service personnel, as defined in Section 1.7.  
1.7  
Definitions  
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL  
Qualified/authorized operating personnel are those who have carefully read the information in this  
manual and have familiarized themselves with the equipment functions, or who have had previous  
experience with the operation of the equipment covered in this manual.  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUALIFIED INSTALLATION PERSONNEL  
Qualified installation personnel are individuals, firms, corporations, and/or companies which, either  
in person or through a representative, are engaged in and are responsible for the installation of gas-  
fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas  
precautions involved, and have complied with all requirements of applicable national and local  
codes.  
QUALIFIED SERVICE PERSONNEL  
Qualified service personnel are those who are familiar with Frymaster equipment and who have been  
authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service  
personnel are required to be equipped with a complete set of service and parts manuals, and to stock  
a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized  
Service Centers (FASC) is included with the fryer when shipped from the factory. Failure to use  
qualified service personnel will void the Frymaster warranty on your equipment.  
1.8  
Shipping Damage Claim Procedure  
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The  
transportation company assumes full responsibility for safe delivery upon its acceptance of the  
equipment for transport.  
What to do if your equipment arrives damaged:  
1. File a claim for damages immediately, regardless of the extent of damages.  
2. Inspect for and record all visible loss or damage, and ensure that this information is noted on  
the freight bill or express receipt and is signed by the person making the delivery.  
3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be  
recorded and reported to the freight company or carrier immediately upon discovery. A  
concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that  
the shipping container is retained for inspection.  
Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS  
INCURRED IN TRANSIT.  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO H55 SERIES GAS FRYER  
CHAPTER 2: INSTALLATION INSTRUCTIONS  
2.1  
General Installation Requirements  
Qualified, licensed, and/or authorized installation or service personnel, as defined in Section  
1.7 of this manual, should perform all installation and service on Frymaster equipment.  
Conversion of this appliance from one type of gas to another should only be performed by  
qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.7  
of this manual.  
Failure to use qualified, licensed, and/or authorized installation or service personnel (as de-  
fined in Section 1.7 of this manual) to install, convert to another gas type or otherwise service  
this equipment will void the Frymaster warranty and may result in damage to the equipment  
or injury to personnel.  
Where conflicts exist between instructions and information in this manual and local or na-  
tional codes or regulations, installation and operation shall comply with the codes or regula-  
tions in force in the country in which the equipment is installed.  
DANGER  
Building codes prohibit a fryer with its open tank of hot oil being installed beside an  
open flame of any type, including those of broilers and ranges.  
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Shipping Damage  
Claim Procedure in Chapter 1.)  
DANGER  
Frymaster appliances equipped with legs are for stationary installations. Appliances  
fitted with legs must be lifted during movement to avoid damage to the appliance  
and bodily injury. For movable installations, optional equipment casters must be  
used. Questions? Call 1-800-551-8633.  
CLEARANCE AND VENTILATION  
The fryer(s) must be installed with a 6” (150 mm) clearance at both sides and back when installed  
adjacent to combustible construction; no clearance is required when installed adjacent to  
noncombustible construction. A minimum of 24” (600 mm) clearance should be provided at the  
front of the fryer.  
DANGER  
No structural material on the fryer should be altered or removed to accommodate  
placement of the fryer under a hood. Questions? Call the Frymaster Dean Service  
Hotline at 1-800-551-8633.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
One of the most important considerations of efficient fryer operation is ventilation. Make sure the  
fryer is installed so that products of combustion are removed efficiently, and that the kitchen  
ventilation system does not produce drafts that interfere with burner operation.  
The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must  
never have its flue extended in a “chimney” fashion. An extended flue will change the combustion  
characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition.  
To provide the airflow necessary for good combustion and burner operation, the areas surrounding  
the fryer front, sides, and rear must be kept clear and unobstructed.  
DANGER  
This appliance must be installed with sufficient ventilation to prevent the occurrence  
of unacceptable concentrations of substances harmful to the health of personnel in  
the room in which it is installed.  
Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate  
distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation  
filter bank. Filters should be installed at an angle of 45º. Place a drip tray beneath the lowest edge  
of the filter. For U.S. installation, NFPA standard No. 96 states, “A minimum distance of 18 in.  
(450 mm) should be maintained between the flue outlet and the lower edge of the grease filter.”  
Frymaster recommends that the minimum distance be 24 in. (600 mm) from the flue outlet to the  
bottom edge of the filter when the appliance consumes more than 120,000 BTU per hour.  
For installations in the United States, information on construction and installation of ventilating  
hoods can be found in the NFPA standard cited above. A copy of the standard may be obtained  
from the National Fire Protection Association, Battery March Park, Quincy, MA 02269.  
NATIONAL CODE REQUIREMENTS  
The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of  
the fryer door. Connect a fryer stamped “NAT” only to natural gas, those stamped “PRO” only to  
propane gas, and those stamped “MFG” only to manufactured gas.  
Installation shall be made with a gas connector that complies with national and local codes, and,  
where applicable, CE codes. Quick-disconnect devices, if used, shall likewise comply with national,  
local, and, if applicable, CE codes.  
ELECTRICAL GROUNDING REQUIREMENTS  
All electrically operated appliances must be grounded in accordance with all applicable national and  
local codes, and, where applicable, CE codes. All units (cord connected or permanently connected)  
should be connected to a grounded power supply system. A wiring diagram is located on the inside  
of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.  
DANGER  
This appliance is equipped with a three-prong (grounding) plug for your protection  
against electrical shock, and must be plugged directly into a properly grounded  
three-prong receptacle. Do not cut, remove, or otherwise bypass the grounding  
prong on this plug!  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
This appliance requires electrical power for operation. Place the gas control valve in  
the OFF position in case of a prolonged power outage. Do not attempt to operate  
this appliance during a power outage.  
AUSTRALIAN REQUIREMENTS  
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other  
relevant statutory regulations.  
FCC COMPLIANCE  
The user is cautioned that any changes or modifications to Frymaster computers not expressly  
approved by the party responsible for compliance could void the user’s authority to operate the  
equipment.  
Frymaster computers have been tested and found to comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A devices,  
they have been shown to meet the Class B limits. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated in a commercial  
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not  
installed and used in accordance with the instruction manual, may cause harmful interference to  
radio communications. Operation of the equipment in a residential area is likely to cause harmful  
interference in which case the user will be required to correct the interference at his own expense.  
The user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems”  
helpful. It is prepared by the Federal Communications Commission and is available from the U.S.  
Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.  
If necessary, the user should consult the dealer or an experienced radio and television technician for  
additional suggestions.  
2.2  
Caster/Leg Installation  
Depending upon the specific configuration ordered, your fryer may have been shipped without  
installed casters or legs. DO NOT INSTALL THIS APPLIANCE WITHOUT CASTERS OR  
LEGS. If the appliance requires the installation of casters or legs, install them in accordance  
with the instructions included in your accessory package.  
2.3  
Pre-Connection Preparations  
DANGER  
DO NOT connect this appliance to the gas supply before completing each step in  
this section.  
After the fryer has been positioned under the exhaust hood, ensure the following has been  
accomplished:  
1. Adequate means must be provided to limit the movement of fryers without depending upon the  
gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all  
times when the fryer is in use. The restraining cable and installation instructions are packed with  
the flexible hose in the accessories box that was shipped with your unit.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Single unit fryers must be stabilized by installing restraining chains on fryers equipped with  
casters or anchor straps on fryers equipped with legs. Follow the instructions in the accessory  
pack to install the chains or straps.  
DANGER  
Do not attach an apron drainboard to a single fryer. The fryer may become unstable,  
tip over, and cause injury. The appliance area must be kept free and clear of  
combustible material at all times.  
3. Level fryers equipped with legs by screwing out the legs approximately 1 inch then adjusting  
them so that the fryer is level and at the proper height in the exhaust hood. Frymaster  
recommends that the minimum distance from the flue outlet to the bottom edge of the hood be 24  
in. (600 mm) when the appliance consumes more than 120,000 BTU per hour. NOTE: There  
are no built-in leveling devices on fryers equipped with casters. The floor where the fryer is to  
be installed must be level.  
4. Test the fryer electrical system:  
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.  
b. Place the power switch in the ON position.  
For fryers equipped with solid-state (analog) controls, verify that the power and heat  
lights are lit.  
For fryers having computer or digital displays, verify that the display indicates CYCL.  
c. Place the fryer power switch in the OFF position. Verify that the power and heat lights are  
out, or that the display is blank.  
5. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is  
configured for the proper type of gas before connecting the fryer quick-disconnect device or  
piping from the gas supply line.  
6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in  
accordance with the accompanying tables.  
CE Standard  
CE Standard  
for Incoming Gas Pressures  
for Incoming Gas Pressures  
for Fryers Manufactured After April 1999  
for Fryers Manufactured Through April 1999  
Orifice Diameter  
Orifice Diameter  
Regulator Pressure  
Regulator Pressure  
Pressure  
(mbar)(1)  
20  
Pressure  
(mbar)(1)  
20  
Single  
Vat  
Dual  
Vat  
Single  
Vat  
Dual  
Vat  
Single  
Vat  
Dual  
Vat  
Single  
Vat  
Dual  
Vat  
Gas  
G20  
G25  
G30  
G31  
Gas  
G20  
G25  
G30  
G31  
2 x 3.40 2 x 3.40 7 mbar  
2 x 3.40 2 x 3.40 10 mbar  
7 mbar  
10 mbar  
17 mbar  
20 mbar  
2 x 3.40 2 x 3.40 7 mbar  
2 x 3.40 2 x 3.40 10 mbar  
7 mbar  
9 mbar  
20 or 25  
20 or 25  
28/30 or 50 2 x 2.05 2 x 2.05 17 mbar  
37 or 50 2 x 2.05 2 x 2.05 20 mbar  
28/30 or 50 2 x 2.05 2 x 2.05 17 mbar 16,5 mbar  
37 or 50 2 x 2.05 2 x 2.05 20,2 mbar 18,5 mbar  
2
2
(1) mbar = 10,2 mm H O  
(1) mbar = 10,2 mm H O  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Non-CE Standard  
for Incoming Gas Pressures  
Gas  
Minimum  
Maximum  
6" W.C.  
1.49 kPa  
14" W.C.  
3.48 kPa  
Natural  
14.93 mbar 34.84 mbar  
11" W.C.  
2.74 kPa  
14" W.C.  
3.48 kPa  
LP  
27.37 mbar 34.84 mbar  
7. For fryers equipped with a FootPrint Pro system or basket lifts, plug the electrical cord(s) into a  
power receptacle behind the fryer.  
2.4  
Connection to Gas Line  
DANGER  
Before connecting new pipe to this appliance, the pipe must be blown out thor-  
oughly to remove all foreign material. Foreign material in the burner and gas con-  
trols will cause improper and dangerous operation.  
DANGER  
When pressure-testing incoming gas supply lines, disconnect the fryer from the gas  
line if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greater to  
avoid damage to the fryer’s gas tubes and gas valve(s).  
DANGER  
All connections must be sealed with a joint compound suitable for the gas being  
used and all connections must be tested with a solution of soapy water before light-  
ing any pilots.  
Never use matches, candles, or any other ignition source to check for leaks. If gas  
odors are detected, shut off the gas supply to the appliance at the main shut-off  
valve and immediately contact the local gas company or an authorized service  
agency for service.  
DANGER  
“Dry-firing” your unit will cause damage to the frypot and can cause a fire. Always  
ensure that melted shortening, cooking oil, or water is in the frypot before firing the  
unit.  
The size of the gas line used for installation is very important. If the line is too small, the gas  
pressure at the burner manifold will be low. This may cause slow recovery and delayed ignition.  
The incoming gas supply line should be a minimum of 1½” (38 mm) in diameter. Refer to the chart  
on the following page for the minimum sizes of connection piping.  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Connection Pipe Sizes  
(Minimum incoming pipe size should be 1 1/2" (41 mm))  
4 or more  
Gas  
Natural  
Single Unit  
2 - 3 Units  
1" (28 mm) 1 1/4" (36 mm)  
1" (28 mm)  
1" (28 mm) 1 1/4" (36 mm) 1 1/2" (41 mm)  
units*  
3/4" (22 mm)  
Propane  
1/2" (15 mm) 3/4" (22 mm)  
Manufactured  
* For distances of more than 20 feet (6 m) and/or more  
than 4 fittings or elbows, increase the connection by one  
pipe size.  
The Pro H55 Series gas fryer has received the CE mark for the countries and gas categories  
indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU  
and category 3P/B, which is 23kW.  
CE Approved Gas Categories by Country  
COUNTRIES  
CATEGORIES  
GAS  
G20  
G30, G31  
G20, G25  
G30, G31  
G20  
G30, G31  
G20, G25  
G30, G31  
G20, G25  
G31  
PRESSURE (MBAR)  
20  
50  
20, 25  
28-30, 37  
20  
AUSTRIA (AT)  
II2H3B/P  
I2E(R)B  
I3+  
BELGIUM (BE)  
DENMARK (DK)  
II2H3B/P  
II2Esi3+  
II2Esi3P  
II2H3B/P  
30  
20, 25  
28-30, 37  
20, 25  
50  
FRANCE (FR)  
G20  
20  
30  
20  
50  
FINLAND (FI)  
G30, G31  
G20, G25  
G30, G31  
G31  
II2ELL3B/P  
I3P  
GERMANY (DE)  
50  
G20  
G30, G31  
G20  
G30, G31  
G20  
G30, G31  
G20  
G30, G31  
G25  
G31  
20  
28-30, 37  
20  
28-30, 37  
20  
28-30, 37  
20  
GREECE (GR)  
ITALY (IT)  
II2H3+  
II2H3+  
II2H3+  
IRELAND (IE)  
LUXEMBOURG (LU)  
II2E3B/P  
II2L3P  
50  
25  
50  
25  
30  
30  
20  
NETHERLANDS (NL)  
G25  
II2L3B/P  
I3B/P  
G30, G31  
G30, G31  
G20  
G30, G31  
G20  
G30, G31  
G20  
G31  
NORWAY (NO)  
PORTUGAL (PT)  
II2H3+  
28-30, 37  
20  
28-30, 37  
20  
37, 50  
20  
30  
II2H3+  
II2H3P  
SPAIN (ES)  
G20  
G30, G31  
G20  
SWEDEN (SE)  
II2H3B/P  
II2H3+  
20  
28-30, 37  
UNITED KINGDOM (UK)  
G30, G31  
CE Standard  
Required airflow for the combustion air supply is 2m3/h per kW.  
2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting under the front of the  
fryer and to the building gas line.  
NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units  
are connected to the gas supply line at the rear of the unit.  
When using thread compound, use very small amounts on male threads only. Use a pipe thread  
compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant  
is one such compound). DO NOT apply compound to the first two threads. Doing so may allow  
some of the compound to enter the gas stream, resulting in clogging of burner orifices and/or the  
control valve.  
2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A  
soap solution should be used for this purpose.  
3. Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom  
OIL LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures  
that are described in the “Lighting Instructions” and “Boiling Out the Frypot” topics found in  
Chapter 3 of this manual.  
DANGER  
“Dry-firing” your unit will cause damage to the frypot and can cause a fire. Always  
ensure that melted shortening, cooking oil, or water is in the frypot before firing your  
unit.  
4. The burner manifold pressure should be checked at this time by the local gas company or an  
authorized service agent. The tables below and on the following page list the burner manifold  
gas pressures for the various gas types that can be used with this equipment.  
CE Standard  
CE Standard  
Burner Manifold Gas Pressures  
for Fryers Manufactured After April 1999  
Burner Manifold Gas Pressures  
for Fryers Manufactured Through April 1999  
Pressure (mbar)  
Pressure (mbar)  
Single  
Vat  
Dual  
Vat  
Single  
Vat  
Dual  
Vat  
Gas  
Natural Gas Lacq  
(G20) under 20 mbar  
Gas  
Natural Gas Lacq  
(G20) under 20 mbar  
7
7
7
10  
6,5  
9
Natural Gas Groningue *  
(G25) under 25 mbar  
Natural Gas Gronigue *  
(G25) under 25 mbar  
10  
10  
17  
20  
10  
10  
17  
20  
Natural Gas Groningue  
(G25) under 20 mbar  
Natural Gas Gronigue  
(G25) under 20 mbar  
10  
9
Butane  
(G30) at 28/30 or 50 mbar  
Butane  
(G30) at 28/30 or 50 mbar  
17  
16,5  
18,5  
Propane  
(G31) under 37 or 50 mbar  
Propane  
(G31) under 37 or 50 mbar  
20,2  
* Belgian G25 = 7,0 mbar (single or dual)  
* Belgian G25 = 7,0 mbar (single) or 6,5 (dual)  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Non-CE Standard  
Burner Manifold Gas Pressures  
Gas  
Pressure  
3" W.C.  
0.73 kPa  
Natural  
8.25" W.C.  
2.5 kPa  
Propane  
5. Check the programmed temperature or solid-state (analog) controller thermostat setting. (Refer  
to the separate Frymaster Fryer Controllers User’s Manual furnished with your unit for the  
setpoint programming instructions for your particular controller.)  
2.5  
Converting to Another Gas Type  
DANGER  
This appliance was configured at the factory for a specific type of gas. Converting  
from one type of gas to another requires the installation of specific gas-conversion  
components.  
Switching to a different type of gas without installing the proper conversion  
components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A  
GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!  
Conversion of this appliance from one type of gas to another should only be  
performed by qualified, licensed, and authorized installation or service personnel, as  
defined in Section 1.7 of this manual.  
Pro H55 Series gas fryers manufactured for Non-CE countries use different burners for each type  
gas. The burners in fryers built for Propane gas have a special gray-colored coating on the burner  
tiles to enable them to withstand the higher caloric value of the Propane gas. Burners designed for  
use in Propane units may be used in natural gas applications, but not vice versa.  
Non-CE Gas Conversion Kits  
Natural Gas to Propane (LP) Gas  
Full Vat: Part Number 826-1145  
Dual Vat: Part Number 826-1147  
Propane (LP) Gas to Natural Gas  
Full Vat: Part Number 826-1146  
Dual Vat: Part Number 826-1148  
Units manufactured for export to CE countries are equipped with “universal” burners that may be  
used with either Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.  
CE Gas Conversion Kits for Units with Gas Valve 810-1715  
G20 or G25 (Natural) to G30 or G31 Gas:  
Part Number 826-1196  
G30 or G31 to G20 or G25 (Natural) Gas:  
Part Number 826-1197  
2-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CE GAS CONVERSION INSTRUCTIONS  
1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the  
CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice.  
2. Between a 2nd family (G20 or G25) and a 3rd family gas (G30 Butane or G31 Propane):  
a. Change the orifices.  
b. Adjust the manifold pressure.  
3. Affix the new label included with the conversion kit next to the existing rating plate stating that  
the gas type has been converted. Remove any references to the previously used gas from the  
existing rating plate. Conversion rating label PN 802-2144.  
4. If the destination language changes, replace the labels. Call your local service agency or KES  
for a label kit. The language of reference will be on the corner of the label.  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THIS PAGE INTENTIONALLY LEFT BLANK  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO H55 SERIES GAS FRYER  
CHAPTER 3: OPERATING INSTRUCTIONS  
3.1  
Controller Operation and Programming  
Pro H55 Series gas fryers can be equipped with any of the following controlling devices:  
Computer Magic III.5  
Solid State (Analog) Controller  
Digital Controller  
Basket Lift Timer  
Refer to the appropriate section of the separate Frymaster Fryer Controllers User’s Manual furnished  
with your fryer for the operating instructions for your specific controller.  
3.2  
Start-Up Procedure  
WARNING  
The on-site supervisor is responsible for ensuring that operators are made aware of  
the inherent hazards of operating a hot oil filtering system, particularly the aspects  
of oil filtration, draining and cleaning procedures.  
CAUTION  
If this is the first time the fryer is being used after installation, refer to Section 3.3,  
Boil-Out Procedure.  
CAUTION  
The cooking oil/shortening capacity of the Pro H55 Series gas fryer is 50 lbs. (25  
liters) at 70°F (21°C) for a full-vat and 25 lbs. (12.5 liters) at 70°F (21°C) for each half  
of a dual-vat.  
Before lighting the fryer, make sure the fryer is OFF and the frypot drain valve(s)  
is/are closed. Remove the basket support rack(s), if installed, and fill the frypot to  
the bottom OIL-LEVEL line.  
If solid shortening is being used, make sure it is packed down into the bottom of the  
frypot.  
WARNING  
Never operate this appliance with an empty frypot. The frypot must be filled with wa-  
ter or cooking oil/shortening before lighting the burners. Failure to do so will dam-  
age the frypot and may cause a fire.  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Lighting the Fryer  
1. Press the computer/controller ON/OFF switch to the OFF position.  
For CE Fryers  
For Non-CE Fryers  
Placing the ON/OFF switch in the OFF  
position also turns off the gas valve. Wait five  
minutes before continuing with Step 2, which  
will also turn on the gas valve.  
After placing the ON/OFF switch in the OFF  
position, turn the gas valve knob to the OFF  
position. Wait 5 minutes, then turn the knob  
to the ON postion and proceed with Step 2.  
2. Press the computer/controller ON/OFF switch to the ON position and set the thermostat or  
program the computer for normal cooking temperature.  
3. If the burners fail to light, press the ON/OFF switch to the OFF position and wait 60 seconds.  
Repeat step 2.  
4. The fryer will automatically enter the melt cycle mode if the frypot temperature is below 180ºF  
(82ºC). (NOTE: During the melt cycle, the burners will repeatedly fire for a few seconds, then  
go out for a longer period.) When the frypot temperature reaches 180ºF (82ºC), the unit will  
automatically switch to the heating mode. The burners will remain lit until the frypot  
temperature reaches the programmed cooking temperature.  
5. After the burners have been lit for at least 90 seconds, observe the flames through the burner  
viewing ports located on each side of the combustion air blower.  
Left Viewing Ports are  
Right Viewing Ports  
behind the motor  
housings.  
The optimum burn is a bright orange-red glow. If a blue flame is observed, or if there are dark spots  
on a burner face, adjust the air gas mixture as follows: On the side of the blower housing opposite  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the motor is a plate with a locking nut. Loosen the nut enough to allow the plate to be moved, then  
adjust the position of the plate to open or close the air intake opening until a bright orange-red glow  
is obtained. Carefully hold the plate in position and tighten the locking nut.  
3.3  
Boiling Out the Frypot  
To ensure that the frypot is free of any contamination resulting from its manufacture, shipping, and  
handling during installation, the frypot must be boiled out before first use. Refer to Drain and Clean  
Frypot (page 5-1) for this procedure.  
3.4  
Shutting the Fryer Down  
For short-term shut down during the workday, place the controller ON/OFF switch in the OFF  
position and put the frypot covers in place (if the fryer is so equipped).  
When shutting the fryers down at closing time, place the controller ON/OFF switch in the OFF  
position. Then place the gas valve in the off position. See illustration below.  
For CE Fryers  
For Non-CE Fryers  
Placing the ON/OFF switch in the OFF After placing the ON/OFF switch in the OFF  
position also turns off the gas valve.  
position, turn the gas valve knob to the OFF  
position.  
Put the frypot covers in place (if the fryer is so equipped).  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THIS PAGE INTENTIONALLY LEFT BLANK  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO H55 SERIES GAS FRYERS  
CHAPTER 4: FILTRATION INSTRUCTIONS  
WARNING  
The on-site supervisor is responsible for ensuring that operators are made aware of  
the inherent hazards of operating a hot oil filtering system, particularly the aspects  
of oil filtration, draining and cleaning procedures.  
4.1  
Draining and Manual Filtering  
DANGER  
Draining and filtering of cooking oil must be accomplished with care to avoid the  
possibility of a serious burn caused by careless handling. The oil to be filtered is at  
or near 350°F (177°C). Ensure all hoses are connected properly and drain handles  
are in their proper position before operating any switches or valves. Wear all  
appropriate safety equipment when draining and filtering cooking oil.  
DANGER  
Allow oil to cool to 100°F (38°C) before draining into an appropriate container for  
disposal.  
DANGER  
Do not drain more than one frypot at a time into the built-in filtration unit to avoid  
overflow and spillage of hot oil.  
DANGER  
When draining oil into a disposal unit or portable filter unit, do not fill above the  
maximum fill line located on the container.  
If your fryer is not equipped with a built-in filtration system, the cooking oil must be drained into  
another suitable container. (For safe, convenient draining and disposal of used cooking oil,  
Frymaster recommends using the Frymaster Shortening Disposal Unit (SDU). The SDU is available  
through your local distributor.)  
1. Turn the fryer power switch to the OFF position. Screw the drainpipe (provided with your fryer)  
into the drain valve. Make sure the drainpipe is firmly screwed into the drain valve and that the  
opening is pointing down.  
2. Position a metal container with a sealable cover under the drainpipe. The metal container must  
be able to withstand the heat of the cooking oil and hold hot liquids. If you intend to reuse the  
oil, Frymaster recommends that a Frymaster filter cone holder and filter cone be used when a  
filter machine is not available. If you are using a Frymaster filter cone holder, be sure that the  
cone holder rests securely on the metal container.  
3. Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food  
particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil will  
rush out creating the potential for severe burns.  
DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage  
to the ball inside will result in leaks and will void the Frymaster warranty.  
4. After draining the oil, clean all food particles and residual oil from the frypot. BE CAREFUL,  
this material may still cause severe burns if it comes in contact with bare skin.  
5. Close the drain valve securely and fill the frypot with clean, filtered or fresh cooking oil or solid  
shortening to the bottom OIL-LEVEL line.  
DANGER  
When using solid shortening, pack the shortening down into the bottom of the  
frypot. DO NOT operate the fryer with a solid block of shortening sitting in the upper  
portion of the frypot. This will cause damage to the frypot and may cause a flash  
fire.  
4.2  
Preparing the Built-In Filtration System for Use  
The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered  
while the other frypots in a battery remain in operation. The FootPrint Pro filtration system is  
available in three different configurations:  
Filter Paper – includes crumb tray, large hold-down ring, and metal filter screen.  
Filter Pad – includes crumb tray, small hold-down ring, and metal filter screen.  
Magnasol Filter – includes crumb tray and Magnasol filter assembly.  
Section 4.2.1 covers preparation of the Filter Paper and Filter Pad configurations for use. Refer to  
Section 4.2.2 for instructions on preparing the Magnasol Filter configuration for use. Operation of  
all three configurations is the same and is covered in section 4.3. Disassembly and reassembly of the  
Magnasol filter is covered in section 4.4.  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.2.1 Preparation for Use with Filter Paper or Filter Pad  
1. Pull the filter pan out from the cabinet  
Screen  
and remove the crumb tray, hold-down  
ring, filter paper and filter screen. (See  
Figure 1) Clean all components with a  
solution of detergent and hot water then  
Filter Paper  
dry thoroughly.  
Crumb Tray  
The filter pan is equipped with rollers in  
rails, much like a kitchen drawer. The  
pan may be removed for cleaning or to  
gain access to interior components by  
lifting the front of the pan to disengage  
the front rollers, then pulling it forward  
until the rear rollers clear the rails. The  
pan cover must not be removed except  
for cleaning, interior access, or to allow  
a shortening disposal unit (SDU) to be  
positioned under the drain.  
Hold-Down Ring  
Figure 1  
2. Inspect the filter pan connection fitting  
to ensure that both O-rings are in good  
Inspect the filter  
condition. (See Figure 2)  
connection fitting  
O-rings.  
3. Then in reverse order, place the metal  
filter screen in the center of the bottom  
of the pan, then lay a sheet of filter paper  
on top of the screen, overlapping on all  
sides. (See Figure 1) If using a filter  
pad, ensure the rough side of the pad is  
up and lay the pad over the screen,  
making sure that the pad is in between  
the embossed ridges of the filter pan.  
Figure 2  
4. Position the hold-down ring over the  
filter paper and lower the ring into the  
pan, allowing the paper to rest on the  
side of the filter pan. (See Figure 3)  
Figure 3  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. When the hold-down ring is in position,  
if using filter paper, sprinkle one cup of  
filter powder evenly over the paper. (See  
Figure 4)  
If using a filter pad, position the hold  
down ring on top of the pad. DO NOT  
use filter powder with the pad.  
Figure 4  
6. Replace the crumb tray in the filter pan, then push the filter pan back into the fryer, positioning it  
all the way to the back of the cabinet.  
4.2.2 Preparation for Use with the Magnasol Filter Assembly  
1. Pull the filter pan out from the cabinet  
and remove the crumb tray and  
Magnasol filter assembly. (See Figure  
5)  
The filter pan is equipped with rollers in  
rails, much like a kitchen drawer. The  
pan may be removed for cleaning or to  
gain access to interior components by  
lifting the front of the pan to disengage  
the front rollers, then pulling it forward  
until the rear rollers clear the rails. The  
Figure 5  
pan cover must not be removed except  
for cleaning, interior access, or to allow  
a shortening disposal unit (SDU) to be  
positioned under the drain.  
NOTE:  
Refer to Section 4.4 for  
Inspect the filter  
screen O-ring.  
instructions on how to disassemble and  
reassemble the Magnasol filter screen  
assembly.  
Figure 6  
2. Inspect the fitting on the bottom of the  
Magnasol filter assembly to ensure that  
the O-ring is present and in good  
condition. (See Figure 6)  
Inspect the filter  
connection fitting  
O-rings.  
3. Inspect the filter pan connection fitting  
to ensure that both O-rings are present  
and in good condition. (See Figure 7)  
Figure 7  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Replace the Magnasol filter assembly in the filter pan, ensuring that the fitting on the bottom of  
the assembly is securely seated in the port in the bottom of the pan. Sprinkle one cup of the  
Magnasol XL filter powder evenly over the screen.  
5. Replace the crumb tray, then push the filter pan back into the fryer, positioning it all the way to  
the back of the cabinet.  
4.3  
Operation of the Filter  
DANGER  
Draining and filtering of cooking oil must be accomplished with care to avoid the  
possibility of a serious burn caused by careless handling. The oil to be filtered is at  
or near 350°F (177°C). Ensure drain handles are in their proper position before  
operating any switches or valves. Wear all appropriate safety equipment when  
draining and filtering cooking oil.  
DANGER  
NEVER attempt to drain cooking oil from the fryer with the burners lit! Doing so will  
cause irreparable damage to the frypot and may cause a flash fire. Doing so will also  
void the Frymaster warranty.  
1. Turn the fryer power OFF. Drain the  
frypot into the filter pan by rotating the  
valves counter clockwise to the right. If  
necessary, use the Fryer's Friend clean-  
out rod to clear the drain from inside the  
frypot.  
Open drain valves  
by rotating 90°.  
DANGER  
Do not drain more than one frypot at a time into the built-in filtration unit to avoid  
overflow and spillage of hot oil.  
DANGER  
NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil will  
rush out creating the potential for severe burns.  
DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage  
to the ball inside will result in leaks and will void the Frymaster warranty.  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install the Power  
Shower in the frypot  
to be filtered.  
2. If an optional Power Shower is included,  
install it now. NOTE: Verify that the  
Power Shower O-ring and gasket are  
present and in good condition and that  
the clean-out screws are installed at each  
corner.  
Snap the optional Power Shower into position.  
DANGER  
If the fryer includes a Power Shower, DO NOT operate the filter without the Power  
Shower in place. Hot oil will spray out of the fryer and cause injury.  
3. After the cooking oil has drained from  
the frypot, pull the filter handle forward  
(outward) to start the pump and begin  
the filtering process. There may be a  
slight delay before the pump activates.  
Pull filter handle forward  
to activate pump.  
4. The filter pump draws the cooking oil through the filter medium and circulates it back up to and  
through the frypot during a 5-minute process called polishing. Polishing cleans the oil by  
trapping solid particles in the filter medium.  
5. After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let  
the filter pump run 10 to 12 seconds after the oil begins to bubble (or sputter from the Power  
Shower openings, if installed). Turn the filter off, remove the Power Shower if installed, and let  
it drain.  
4-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
The filter pump is equipped with a manual reset switch in case the filter motor  
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter  
system and allow the pump motor to cool 20 minutes before attempting to reset the  
switch (see photo below).  
Filter Pump Reset Switch  
6. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not  
operate.) Turn the fryer ON and allow the cooking oil to reach setpoint.  
DANGER  
The crumb tray in fryers equipped with a filter system must be emptied into a  
fireproof container at the end of frying operations each day. Some food particles can  
spontaneously combust if left soaking in certain shortening material.  
WARNING  
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is  
present to seal the joint between the fry vessels. Banging fry baskets on the strip to  
dislodge shortening will distort the strip, adversely affecting its fit. It is designed for  
a tight fit and should only be removed for cleaning.  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4  
Disassembly and Reassembly of the Magnasol Filter  
Dissassembly  
1. Grasp the frame with your thumbs on the handles at the corner of the assembly and pull outward  
in opposite directions to separate the frame at the corner. Continue to open the frame (it will  
pivot at the opposite corner) until the outer screens and grid can be removed from the frame.  
Step 2 - Separate  
the outer screens  
and grid.  
Step 1 - Grasp frame with  
thumbs on these handles and  
pull frame appart at corner.  
2. Separate the outer screens and grid.  
Cleaning  
1. Clean the two frame pieces, outer screens, and grid using a good quality degreaser and hot water  
from a spray nozzle. The groove in the seal frame pieces can be cleaned with the edge of a  
Scotch-Brite™ or similar cleaning pad.  
2. At each scheduled boil-out, disassemble the leaf filter assembly and place in the frypot being  
boiled out. Follow the boil-out procedure in Section 5.1.2 of this manual.  
3. Allow all filter assembly components to air dry or thoroughly dry with clean towels before  
reassembling.  
Reassembly  
1. Place the two outer screens together and align their edges (see illustration on following page).  
2. Insert the screens into one of the frame halves (it doesn’t matter which one). Ensure that the  
fitting in the bottom screen is on the opposite side of the frame from the handle.  
3. Slip the grid between the screens, ensuring that the grid is centered between the edges of the  
screens.  
4. Connect the other half of the frame at the corner opposite the handles and pivot the frame onto  
the free edges of the screen.  
4-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Steps 1 and 2 - Stack outer screens  
and insert edges into frame.  
Step 3 - Insert grid between screens  
after screens have been positioned in  
frame.  
Step 4 - Connect corner then pivot  
frame over free edges of screens.  
Handle  
4.5  
Draining and Disposing of Waste Oil  
When your cooking oil has reached the end of its usable life, drain the oil into an appropriate  
container for transport to the disposal container. Frymaster recommends the use of the Frymaster  
Shortening Disposal Unit (SDU). NOTE: If using an SDU built before January 2004 the filter pan  
cover must be removed to allow the unit to be positioned beneath the drain. To remove the lid, lift up  
on the front edge and pull it straight out of the cabinet. Refer to the documentation furnished with  
your disposal unit for specific operating instructions. If a shortening disposal unit is not available,  
allow the oil to cool to 100°F (38°C), then drain the oil into a metal stockpot or similar metal  
container. When draining is finished, close the fryer drain valve securely.  
DANGER  
Allow oil to cool to 100°F (38°C) before draining into an appropriate container for  
disposal.  
When draining oil into a disposal unit, do not fill above the maximum fill line located  
on the container.  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.6  
Using the Optional Rear-Discharge Oil Disposal  
1. Ensure the filter pan is clean and ready for filtering. DO  
NOT discharge oil through a dirty or incomplete filter  
pan.  
2. Ensure the oil is at operating temperature.  
3. Turn the fryer off. Wear protective clothing and use  
caution. Hot oil can cause serious injury.  
4. Open the drain valve of the frypot with oil to be  
discarded. Drain only one frypot at a time.  
5. With the frypot drained and the oil to be discarded in the  
filter pan, close the drain valve. Ensure all other drain  
valves and oil-return valves are closed.  
6. Ensure the oil disposal reservoir is not full and the fryer  
is properly connected to the oil disposal system.  
7. Discharge the oil by pressing down on the discharge  
valve handle. The filter pump will come on and the oil  
will be pumped from the filter pan. Turn the pump off  
by lifting the discharge handle to the off position when  
the filter pan empties. Repeat steps 1-7 if necessary to  
discharge the oil from other frypots. DO NOT discharge  
water or other liquids through the filter system.  
8. Refill the fryer with fresh oil.  
The oil discharge valve handle is  
shown in the OFF position. Push it  
down to discharge oil from the filter  
pan.  
4-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO H55 SERIES GAS FRYERS  
CHAPTER 5: PREVENTIVE MAINTENANCE  
5.1  
Fryer Preventive Maintenance Checks and Service  
DAILY CHECKS AND SERVICE  
Inspect Fryer and Accessories for Damage  
Look for loose or frayed wires and cords, leaks, foreign material in frypot or inside cabinet, and any  
other indications that the fryer and accessories are not ready and safe for operation.  
Clean Fryer Cabinet Inside and Out  
Clean inside the fryer cabinet with dry, clean cloth. Wipe all accessible metal surfaces and compo-  
nents to remove accumulations of oil or shortening and dust.  
Clean the outside of the fryer cabinet with a clean, damp cloth soaked with dishwashing detergent,  
removing oil, dust, and lint from the fryer cabinet.  
DANGER  
Never attempt to clean fryer during the cooking process or when the frypot is filled  
with hot oil. If water comes in contact with oil heated to cooking temperature, it can  
cause the oil to splatter and severely burn nearby personnel.  
WEEKLY CHECKS AND SERVICE  
Drain and Clean Frypot  
During normal usage of your fryer, a deposit of carbonized cooking oil will gradually form on the  
inside of the frypot. This deposit must be periodically removed to maintain your fryer’s efficiency.  
DANGER  
Allow oil to cool to 100ºF (38ºC) or lower before draining to an appropriate container  
for disposal.  
1. Drain the frypot in accordance with Section 4.1 (page 4-1), but do not refill with cooking oil.  
2. After draining the frypot, clean all food particles and residual oil from the frypot and filter pan  
(if so equipped). BE CAREFUL, this material may still cause severe burns if it comes in contact  
with bare skin.  
3. Close the drain valve securely and fill the frypot with a solution of automatic dishwasher  
detergent and water (or commercially available boil-out solution) to the bottom OIL-LEVEL  
line.  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Set the thermostat to 195ºF (91ºC) or program the computer for Boil-Out (see separate Frymas-  
ter Fryer Controllers User’s Manual) and simmer the solution for 1 hour.  
WARNING  
Never leave the fryer unattended during this process. If the solution overflows,  
press the ON/OFF switch to the OFF position immediately.  
5. After the solution has simmered for 1 hour, press the ON/OFF switch to the OFF position and  
allow the solution to cool.  
6. Drain the solution into a suitable container (NOT the built-in filtration system filter pan or  
the Shortening Disposal Unit) and thoroughly wipe the frypot with a clean towel.  
7. Close the drain valve and fill the frypot with clean, cold water and drain into a suitable container  
(NOT the built-in filtration system filter pan or the Shortening Disposal Unit). Repeat the  
rinse process again, and then wipe frypot with a clean, dry towel.  
DANGER  
Ensure that the frypot is completely free of water before filling with cooking oil or  
shortening. When the oil or shortening is heated to cooking temperature, water in  
the frypot will cause splattering.  
Clean Filter Pan, Detachable Parts and Accessories  
As with the frypot, a deposit of carbonized oil will accumulate on the filter pan and detachable parts  
and accessories such as baskets, sediment trays, or fish plates.  
Wipe the filter pan and all detachable parts and accessories with a clean cloth dampened with a  
detergent solution (or the parts can be run through a dishwasher). Rinse and thoroughly dry each  
part. DO NOT use steel wool or abrasive pads to clean these parts. The scratches that result from  
such scrubbing make subsequent cleanings more difficult.  
WARNING  
Use a commercial-grade cleaner formulated to effectively clean and sanitize  
food-contact surfaces. Read the directions for use and precautionary statements be-  
fore use. Particular attention must be paid to the concentration of cleaner and the  
length of time the cleaner remains on the food-contact surfaces.  
5-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MONTHLY CHECKS AND SERVICE  
Check Calibration of Analog Controller Thermostat Control Knob  
(This check applies only to units equipped with Analog Controllers)  
1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer  
temperature-sensing probe and set the thermostat knob to frying temperature.  
2. After the set temperature is reached, let the burner cycle on and off automatically three times to  
allow the cooking oil temperature to become uniform. If necessary, stir to get all shortening in  
the bottom of the frypot melted.  
3. When the burner starts for the fourth time, the thermometer/pyrometer reading should be within  
± 5ºF (2ºC) of the thermostat knob setting. If it is not, calibrate as follows:  
a. Loosen setscrew in thermostat control knob until the knob will rotate freely on its shaft.  
b. Rotate the knob until the index line on the knob is aligned with the marking that corresponds  
to the thermometer or pyrometer reading.  
c. Hold the knob and carefully tighten the setscrew.  
d. Recheck the thermometer/pyrometer reading against the thermostat knob setting the next  
time the burner lights.  
e. Repeat steps 3.a. through 3.d. until the thermometer/pyrometer reading and knob setting  
agree within ± 5ºF (2ºC). If calibration cannot be obtained for any reason, call a Factory  
Authorized Service Center for assistance.  
5. Remove the thermometer or pyrometer.  
Check Computer Magic III.5 Set Point Accuracy  
(This check applies only to units equipped with Computer Magic III.5 Controllers.)  
1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer  
temperature-sensing probe.  
2. When the computer display shows a series of four dashes “----” with no dot between the first and  
second dashes (indicating that the frypot contents are within the cooking range), press the  
switch once to display the temperature of the cooking oil as sensed by the temperature probe.  
3. Press the  
switch twice to display the set point.  
4. Note the temperature on the thermometer or pyrometer. All three readings should be within  
± 5ºF (2ºC) of each other. If not, contact a Factory Authorized Service Center for assistance.  
5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUARTERLY CHECKS AND SERVICE  
Clean Combustion Air Blower Assembly  
1. Disconnect the blower wiring harness and remove the four blower mounting nuts.  
Blower  
assembly  
mounting nuts  
Wiring connection  
2. Remove the three fasteners that secure the blower motor assembly to the blower housing, and  
separate the two components.  
Remove these fasteners.  
3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or  
detergent on the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse  
the wheel and housing with hot tap water, then dry with a clean cloth.  
Wrap the motor and wires  
with plastic wrap or a  
plastic bag.  
Blower Housing  
Blower Wheel  
5-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor  
assembly and blower housing. Reinstall the blower assembly in the fryer.  
5. Reinstall the blower shield or shield assembly.  
6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1.  
7. After the burners have been lit for at least 90 seconds, observe the flames through the burner  
viewing ports located on each side of the combustion air blower.  
Left Viewing  
Port is Behind  
Motor  
(NOTE: Blower  
shield omitted  
for clarity.)  
Right  
Viewing  
Port  
The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the  
applicable table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is  
observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment.  
On the side of the blower housing opposite the motor is a plate with one or two locking nuts.  
Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open  
or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in  
position and tighten the locking nut(s).  
SOME CE BLOWER ASSEMBLIES  
MAY BE CONFIGURED THIS WAY  
TYPICAL BLOWER ASSEMBLY  
5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEMI-ANNUAL CHECKS AND SERVICE  
Clean Gas Valve Vent Tube  
NOTE: This procedure is not required for fryers configured for export to CE  
countries.  
1. Set the fryer power switch and the gas valve to the OFF position.  
2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened  
for ease in removal.  
3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any  
obstruction.  
4. Remove the wire and blow through the tube to ensure it is clear.  
5. Reinstall the tube and bend it so that the opening is pointing downward.  
Check Burner Manifold Pressure  
DANGER  
This task should be performed by qualified service personnel only. Contact your  
FASC to arrange this service.  
5.2  
Built-in Filtration System Preventive Maintenance Checks and Service  
WARNING  
Never operate the filter system without cooking oil or shortening in the system.  
WARNING  
Never use the filter pan to transport old oil to the disposal area.  
WARNING  
Never drain water into the filter pan. Water will damage the filter pump.  
There are no periodic preventive maintenance checks and services required for your FootPrint Pro  
Filtration System other than daily cleaning of the filter pan with a solution of hot water and  
detergent.  
If you notice that the system is pumping slowly or not at all, verify that the filter pan screen is on the  
bottom of the filter pan, with the paper on top of the screen. (If the unit is equipped with a Magnasol  
filter screen rather than with the standard screen and paper system, verify that the O-ring on the  
bottom fitting of the screen in present and in good condition.) Verify that the two O-ring(s) on the  
fitting at the right front of the filter pan are present and in good condition.  
5-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GASKET  
O-RING  
CLEAN-OUT PLUGS  
If the system is equipped with a Power Shower, drain the Power Shower completely after each use.  
If oil is leaking at the point where the Power Shower plugs into the frypot, verify that the O-ring and  
gasket on the connection fitting are present and in good condition. If you suspect blockage, unscrew  
the clean-out plugs at each corner of the frame. Place the frame in a pan of hot water for several  
minutes to melt any accumulation of solidified oil/shortening. Use a long, narrow bottlebrush with  
hot water and detergent to clean inside the tubes. If necessary, insert a straightened paper clip or  
similarly sized wire into the holes in the frame to remove any solidified shortening or other  
blockages. Rinse with hot water, dry thoroughly, and reinstall the plugs before using.  
DANGER  
Failure to reinstall the clean-out plugs in the Power Shower will cause hot oil to  
spray out of the frypot during the filtering process, creating an extreme burn hazard  
to personnel.  
5.3  
Annual/Periodic System Inspection  
This appliance should be inspected and adjusted periodically by qualified service personnel as  
part of a regular kitchen maintenance program.  
Frymaster recommends that a Factory Authorized Service Technician inspect this appliance at  
least annually as follows:  
Fryer  
Inspect the cabinet inside and out, front and rear for excessive oil.  
Verify that the flue opening is not obstructed by debris or accumulations of solidified oil or  
shortening.  
Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.)  
are in good condition and functioning properly. Inspect all gas connections for leaks and verify  
that all connections are properly tightened.  
Verify that the burner manifold pressure is in accordance with that specified on the appliance’s  
rating plate.  
5-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Verify that the temperature and high-limit probes are properly connected, tightened and  
functioning properly, and that probe guards are present and properly installed.  
Verify that component box components (i.e. computer/controller, transformers, relays, interface  
boards, etc.) are in good condition and free from oil and other debris. Inspect the component box  
wiring and verify that connections are tight and that wiring is in good condition.  
Verify that all safety features (i.e. drain safety switches, reset switches, etc.) are present and  
functioning properly.  
Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in  
serviceable condition.  
Verify that wiring harnesses and connections are tight and in good condition.  
Built-In Filtration System  
Inspect all oil-return and drain lines for leaks and verify that all connections are tight.  
Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the  
crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof  
container and cleaned daily.  
Verify that all O-rings and seals (including those on the Power Shower if applicable and on the  
quick-disconnect fitting) are present and in good condition. Replace O-rings and seals if worn or  
damaged.  
Check filtration system integrity as follows:  
Verify that filter pan cover is present and properly installed.  
With the filter pan empty, place each oil return handle, one at a time, in the ON position.  
Verify that the pump activates and that bubbles appear in the cooking oil/shortening (or that  
gurgling is heard from the Power Shower port if applicable) of the associated frypot.  
Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify  
proper functioning of each oil return valve by activating the filter pump using the lever on  
one of the oil return microswitches. No air bubbles should be visible in any frypot (or no  
gurgling should be heard from the Power Shower ports if applicable).  
Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to  
350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle  
in the ON position. Allow all cooking oil to return to the frypot (indicated by bubbles in the  
cooking oil or on units with Power Showers, cessation of oil flow from the Power Shower).  
Return the oil return handle to the OFF position. The frypot should have refilled in no more  
than 2 minutes and 30 seconds.  
5-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO H55 SERIES GAS FRYERS  
CHAPTER 6: OPERATOR TROUBLESHOOTING  
6.1  
Introduction  
This chapter provides an easy reference guide to some of the common problems that may occur  
during the operation of your equipment. The troubleshooting guides that follow are intended to help  
you correct, or at least accurately diagnose, problems with your equipment. Although the chapter  
covers the most common problems reported, you may encounter problems that are not covered. In  
such instances, the Frymaster Technical Services staff will make every effort to help you identify  
and resolve the problem.  
When troubleshooting a problem, always use a process of elimination starting with the simplest  
solution and working through to the most complex. Most importantly, always try to establish a clear  
idea of why a problem has occurred. Part of your corrective action involves taking steps to ensure  
that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all  
other connections while you’re at it. If a fuse continues to blow, find out why. Always keep in mind  
that failure of a small component may often be indicative of potential failure or incorrect functioning  
of a more important component or system.  
Some of the troubleshooting actions that are recommended in this chapter involve removing suspect  
components and substituting components that are known to be good. Whenever this in indicated,  
refer to Sections 6.6 for specific instructions  
If you are in doubt as to the proper action to take, do not hesitate to call the Frymaster Technical  
Service Department or your local Frymaster Factory Authorized Service Center for assistance.  
Before calling a servicer or the Frymaster HOTLINE (1-800-551-8633):  
Verify that electrical cords are plugged in and that circuit breakers are on.  
Verify that gas line quick-disconnects are properly connected.  
Verify that any gas line cutoff valves are open.  
Verify that frypot drain valves are fully closed.  
DANGER  
Hot cooking oil will cause severe burns. Never attempt to move this appliance when  
filled with hot cooking oil or to transfer hot cooking oil from one container to another.  
DANGER  
This equipment should be unplugged when servicing, except when electrical circuit  
tests are required. Use extreme care when performing such tests.  
This appliance may have more than one electrical power supply connection point.  
Disconnect all power cords before servicing.  
Inspection, testing, and repair of electrical components should be performed by an  
authorized service agent only.  
6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.2  
Troubleshooting Fryers with Computer Magic III.5, Basket Lift Timer, or Digital  
Controller  
PROBLEM  
PROBABLE CAUSES  
CORRECTIVE ACTION  
A. Press the ON/OFF switch to turn  
the controller on.  
A. Controller not turned on.  
B. Verify that the fryer is plugged in  
and that the circuit breaker is not  
tripped.  
B. No power to fryer.  
C. If available, substitute a harness  
known to be good for the suspect  
harness. If the fryer functions  
correctly, order replacement  
harness from FASC.  
No display on  
computer or  
controller.  
C. Damaged computer/controller  
wiring harness.  
D. If available, substitute a  
computer/controller known to be  
working for the suspect  
D. Failed computer/controller.  
computer/controller. If the fryer  
functions correctly, order  
replacement from FASC.  
If available, substitute a harness  
known to be good for the suspect  
harness. If the fryer functions  
correctly, order replacement  
harness from FASC.  
Display shows  
with alarm  
Damaged computer/controller  
wiring harness or connector.  
sounding.  
A. Drain valve not fully closed.  
A. Press the ON/OFF switch off,  
close the drain valve(s)  
completely, then press the  
ON/OFF switch on.  
B. Turn the gas valve knob to the  
ON position.  
B. Gas valve is not turned on.  
Display shows  
with alarm  
sounding. Heating  
indicator is on, but  
burners will not  
light.  
C. Verify that any in-line manual  
shut off valve is open. Verify that  
gas main cut off valve is open.  
D. Verify that the quick-disconnect  
fitting on the flexible gas line is  
firmly connected to the fryer.  
E. Verify that combustion air blower  
is running. If not, call FASC for  
service. If combustion air blower  
is functional, clean and adjust per  
instructions in Chapter 5 of this  
manual.  
C. Manual gas shut off valve closed.  
D. Improperly connected quick-  
disconnect fitting on gas line.  
E. Obstructed or failed combustion  
air blower.  
6-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROBLEM  
PROBABLE CAUSES  
CORRECTIVE ACTION  
A. If available, substitute a  
computer/controller known to be  
working for the suspect  
Display shows  
,
A. Failed computer/controller.  
computer/controller. If the fryer  
functions correctly, order  
replacement from FASC.  
heating indicator  
cycles on and off  
normally, but  
B. If available, substitute a harness  
known to be good for the suspect  
harness. If the fryer functions  
correctly, order replacement  
harness from FASC.  
burners will not  
light and blower is  
not running.  
B. Damaged computer/controller  
wiring harness.  
Fryer is slow coming  
out of melt cycle.  
Display shows  
Dirty or obstructed combustion air  
blower.  
Clean and adjust per instructions  
in Chapter 5 of this manual.  
a short time  
after coming out of  
melt cycle.  
Fryer is operating  
normally, but  
Dirty or obstructed combustion air  
blower.  
Clean and adjust per instructions  
in Chapter 5 of this manual.  
recovery is slow  
when cooking.  
A. Dirty or obstructed combustion air A. Clean and adjust per instructions  
Fryer is operating  
normally, but  
produces a popping  
sound when burners  
ignite.  
blower.  
in Chapter 5 of this manual.  
B. Dirty or obstructed gas valve vent B. Clean per instructions in Chapter  
tube (non-CE fryers only).  
C. Malfunctioning combustion air  
blower.  
5 of this manual.  
C. If blower is slow to come up to  
speed, contact FASC for service.  
If available, substitute a  
Display shows  
and alarm  
sounds, but fryer  
operates normally  
(false alarm).  
computer/controller known to be  
working for the suspect  
computer/controller. If the fryer  
functions correctly, order  
replacement from FASC.  
If available, substitute a  
computer/controller known to be  
working for the suspect  
computer/controller. If the fryer  
functions correctly, order  
replacement from FASC.  
Failed computer/controller.  
Failed computer/controller.  
Computer will not  
go into program  
mode or some  
buttons do not  
actuate.  
Heat indicator is on  
and blower is  
running, but burner  
will not ignite.  
Blown fuse on interface board or  
ignition module.  
Replace fuse.  
6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROBLEM  
PROBABLE CAUSES  
CORRECTIVE ACTION  
If available, substitute a  
computer/controller known to be  
working for the suspect  
computer/controller. If the fryer  
functions correctly, order  
replacement from FASC.  
Heat indicator off  
upon initial startup.  
Display shows  
Failed computer/controller.  
or  
with alarm  
sounding.  
6.3  
Troubleshooting Fryers with Solid State (Analog) Controller  
PROBLEM  
PROBABLE CAUSES  
A. No power to fryer.  
CORRECTIVE ACTION  
A. Verify that the fryer is plugged in  
and that the circuit breaker is not  
tripped.  
B. If available, substitute a harness  
known to be good for the suspect  
harness. If the fryer functions  
correctly, order replacement  
harness from FASC.  
B. Damaged controller wiring  
harness.  
Power switch ON, no  
lights on controller,  
fryer does not heat.  
C. If available, substitute a controller  
known to be working for the  
suspect controller. If the fryer  
functions correctly, order  
C. Failed controller.  
replacement from FASC.  
If available, substitute a harness  
known to be good for the suspect  
harness. If the fryer functions  
correctly, order replacement  
harness from FASC.  
Power light ON,  
trouble light ON,  
heating mode light  
OFF.  
Damaged controller wiring  
harness.  
A. Press the ON/OFF switch off,  
close the drain valve(s)  
A. Drain valve not fully closed.  
completely, then press the  
ON/OFF switch on.  
B. Turn the gas valve knob to the  
ON position.  
B. Gas valve is not turned on.  
C. Verify that any in-line manual  
shut off valve is open. Verify that  
gas main cut off valve is open.  
D. Verify that the quick-disconnect  
fitting on the flexible gas line is  
firmly connected to the fryer.  
E. Verify that combustion air blower  
is running. If not, call FASC for  
service. If combustion air blower  
is functional, clean and adjust per  
instructions in Chapter 5 of this  
manual.  
Power light ON,  
trouble light ON,  
heating mode light  
ON. Burners do not  
ignite.  
C. Manual gas shut off valve closed.  
D. Improperly connected quick-  
disconnect fitting on gas line.  
E. Obstructed or failed combustion  
air blower.  
6-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROBLEM  
PROBABLE CAUSES  
CORRECTIVE ACTION  
A. If available, substitute a controller  
known to be working for the  
suspect controller. If the fryer  
functions correctly, order  
Heating mode light A. Failed controller.  
cycles on and off  
normally. Blower  
replacement from FASC.  
not running and  
burners will not  
B. If available, substitute a harness  
known to be good for the suspect  
harness. If the fryer functions  
correctly, order replacement  
harness from FASC.  
B. Damaged controller wiring  
ignite.  
harness.  
Fryer is slow coming  
out of melt cycle.  
Heating mode light  
is ON. Trouble light  
comes on a short  
time after coming  
out of melt cycle.  
Fryer is operating  
normally, but  
Dirty or obstructed combustion air  
blower.  
Clean and adjust per instructions  
in Chapter 5 of this manual.  
Dirty or obstructed combustion air  
blower.  
Clean and adjust per instructions  
in Chapter 5 of this manual.  
recovery is slow  
when cooking.  
A. Obstructed combustion air  
blower.  
B. Dirty or obstructed gas valve vent B. Clean per instructions in Chapter  
tube (non-CE fryers only).  
C. Malfunctioning combustion air  
blower.  
A. Clean and adjust per instructions  
in Chapter 5 of this manual.  
Fryer is operating  
normally, but  
produces popping  
sound when burners  
ignite.  
5 of this manual.  
C. If blower is slow to come up to  
speed, contact FASC for service.  
Heating mode light  
is on and blower is  
running, but burner  
will not ignite.  
Blown fuse on interface board or  
ignition module.  
Replace fuse.  
A. If available, substitute a controller  
known to be working for the  
suspect controller. If the fryer  
functions correctly, order  
Heating mode light  
is cycling on and off A. Failed controller.  
normally and fryer  
is operating  
replacement from FASC.  
normally, but  
trouble light is on  
continuously (false  
alarm).  
B. If available, substitute a harness  
known to be good for the suspect  
harness. If the fryer functions  
correctly, order replacement  
harness from FASC.  
B. Damaged controller wiring  
harness.  
6-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROBLEM  
PROBABLE CAUSES  
CORRECTIVE ACTION  
Heating mode light  
is ON with power  
switch in OFF  
If available, substitute a controller  
known to be working for the  
suspect controller. If the fryer  
functions correctly, order  
position. After  
initial startup, fryer  
continues to heat  
until trouble light  
comes on. Frypot  
temperature is  
Failed controller.  
replacement from FASC.  
above 410F (210°C).  
6.4  
Troubleshooting the Built-in Filtration System  
PROBLEM  
PROBABLE CAUSES  
CORRECTIVE ACTION  
A. If the pump runs normally after  
resetting the thermal overload  
switch, the pump was overheated.  
A. Thermal overload switch has  
tripped on an overheated motor.  
Test: If the pump stopped  
suddenly during the filtering  
process, especially if after several  
filtering cycles, the pump motor  
has probably overheated. Place  
the filter handle in the OFF  
position, allow the pump to cool  
for at least 45 minutes, and then  
press the reset button on the pump  
motor. Attempt to activate the  
pump.  
Always filter with the cooking oil  
at or near frying temperature.  
Allow the pump motor to cool off  
for about ten minutes after  
filtering two full frypots one after  
the other.  
Check the filter paper between  
filterings. Replace the paper if  
there is a large accumulation of  
sediment.  
Pump won’t start.  
OR  
B. Failed filter handle microswitch.  
Pump stops during  
filtering.  
Test: If this is a multi-pot fryer,  
attempt to operate the pump using  
a different handle. If the pump  
starts, the handle microswitch is  
either out of alignment or has  
failed.  
B. If the switch is loose, tighten the  
nuts and bolts holding it in place,  
ensuring that when the handle is  
placed in the ON position, the  
lever on the microswitch is  
pressed firmly against the switch.  
When the handle is placed in the  
ON position, the lever on the  
microswitch should be firmly  
pressed against the switch. If so,  
the switch has failed. If not, the  
switch is loose and/or misaligned.  
If the switch has failed, call  
FASC.  
6-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROBLEM  
PROBABLE CAUSES  
C. Pump blockage.  
CORRECTIVE ACTION  
C. Pump blockages are usually  
caused by sediment build-up in  
the pump due to improperly sized  
or installed filter paper and failure  
to use the crumb screen. Call  
FASC to have blockage cleared.  
Test: Close the drain valve. Place  
the filter handle in the OFF  
position, allow the pump to cool  
for at least 45 minutes, and then  
press the reset button on the pump  
motor. Pull the filter pan from the  
unit and then activate the pump.  
If the pump motor hums and then  
stops, the pump is blocked.  
(Continued from  
previous page.)  
Ensure that filter paper is of the  
proper size and is installed  
properly, and that the crumb  
screen is used.  
A. To properly filter, the oil should  
be at or near 350°F (177°C). At  
temperatures lower than this, the  
oil becomes too thick to pass  
through the filter medium easily,  
resulting in much slower oil  
return and eventual overheating of  
the filter pump motor.  
A. Cooking oil is too cold for  
filtering.  
B. Improperly installed or prepared  
filter pan components.  
Pump starts, but no  
transfer takes place  
or the transfer is  
very slow.  
B. Remove the oil from the filter pan  
and replace the filter paper,  
Test: Close the drain valve.  
Move the filter handle to the OFF  
position, pull the filter pan (and  
Power Shower, if so equipped)  
from the unit. Move the filter  
handle to the ON position.  
ensuring that the filter screen is in  
place under the paper.  
C. If this does not correct the  
problem, the filter suction tube is  
probably blocked. Remove the  
blockage using a thin, flexible  
wire. If unable to remove the  
blockage, call FASC.  
If a strong stream of air is being  
pumped out of the oil return port  
(or the Power Shower port), the  
problem is with the filter pan  
components.  
A. Plugged openings or solidified  
shortening in the Power Shower.  
A. Clean the Power Shower per  
instructions in Chapter 5 of this  
manual.  
Test: Look for oil squirting out  
around the Power Shower gasket  
but not coming out of the holes  
around the frame. If so, Power  
Shower is obstructed.  
Power Shower is not  
spraying properly.  
B. Missing/worn o-rings and gasket B. Verify that o-rings and gasket are  
on Power Shower. present and in good condition.  
6-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROBLEM  
PROBABLE CAUSES  
C. Missing paper in filter pan. (This  
causes too much pressure in the  
oil return lines, resulting in a  
strong flow through the Power  
Shower, but also squirting of oil  
from around the gasket.)  
CORRECTIVE ACTION  
(Continued from  
previous page.)  
C. Verify that filter paper is properly  
installed in the filter pan.  
6.5  
Troubleshooting the Basket Lift  
PROBLEM  
Basket lift  
movement is jerky  
and/or noisy.  
PROBABLE CAUSES  
Basket lift rods need lubrication.  
CORRECTIVE ACTION  
Lubricate basket lift rods with  
Lubriplate™ or equivalent light  
white grease.  
6-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000  
Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106  
TEL 1-318-865-1711  
FAX (Parts) 1-318-219-7140  
FAX (Tech Support) 1-318-219-7135  
SERVICE HOTLINE  
1-800-551-8633  
819-5991  
SEPTEMBER 2005  
PRINTED IN THE UNITED STATES  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Dyson Vacuum Cleaner DC07 User Manual
Echo Brush Cutter SRM 265 User Manual
Ei Electronics Smoke Alarm Ei 204EN User Manual
Electrolux Oven EOK86030 User Manual
Fellowes Chipper M 8C User Manual
Frymaster Fryer PF50R User Manual
Garmin Marine GPS System 4010 User Manual
GE Air Conditioner 000 BTU models User Manual
GE Answering Machine 27851FE1 User Manual
GE Microwave Oven 49 40614 User Manual