FMI Indoor Fireplace FMH26TN User Manual

COMPACT HEAT MAJIC™  
VENT-FREE NATURAL GAS FIREPLACE SYSTEM  
OWNER’S OPERATION AND INSTALLATION MANUAL  
FMH26TN  
14,000 to 26,000 Btu/Hr  
with Thermostat  
Shown with Optional  
Cabinet Mantel/Hearth  
Base Accessory  
WARNING: Improper installa-  
WARNING: If the information in this manual  
tion,adjustment,alteration,ser-  
is not followed exactly, a fire or explosion  
vice,ormaintenancecancause  
may result causing property damage, per-  
sonal injury, or loss of life.  
injury or property damage. Re-  
fer to this manual for correct  
— Do not store or use gasoline or other  
flammable vapors and liquids in the  
vicinity of this or any other appliance.  
installationandoperationalpro-  
cedures. For assistance or ad-  
ditional information consult a  
qualified installer, service  
agency, or the gas supplier.  
— WHAT TO DO IF YOU SMELL GAS  
• Do not try to light any appliance.  
• Do not touch any electrical switch; do  
not use any phone in your building.  
• Immediatelycallyourgassupplierfrom  
a neighbor’s phone. Follow the gas  
supplier’s instructions.  
WARNING:Thisisanunvented  
gas-fired heater. It uses air  
(oxygen) from the room in  
whichitisinstalled.Provisions  
for adequate combustion and  
ventilation air must be pro-  
vided.RefertoAirforCombus-  
tion and Ventilation section on  
page 5 of this manual.  
• If you cannot reach your gas supplier,  
call the fire department.  
— Installation and service must be per-  
formed by a qualified installer, service  
agency, or the gas supplier.  
This appliance may be installed in an aftermarket*, permanently located, manufactured  
(mobile) home, where not prohibited by local codes.  
This appliance is only for use with the type of gas indicated on the rating plate. This  
appliance is not convertible for use with other gases.  
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer  
Save this manual for future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
SAFETY  
PRODUCT  
FEATURES  
LOCAL CODES  
INFORMATION  
Install and use fireplace with care. Follow all  
localcodes.Intheabsenceoflocalcodes,use  
the latest edition of The National Fuel Gas  
Code ANSI Z223.1/NFPA 54*.  
Continued  
SAFETY PILOT  
14. Turn off and unplug fireplace and let  
cool before servicing. Only a qualified  
service person should service and re-  
pair fireplace.  
This fireplace has a pilot with an Oxygen  
DepletionSensing(ODS)safetyshutoffsys-  
tem. The ODS/pilot is a required feature for  
vent-free room fireplaces. The ODS/pilot  
shuts off the fireplace if there is not enough  
fresh air.  
*Available from:  
American National Standards Institute, Inc.  
1430 Broadway  
15. Operating fireplace above elevations of  
4,500 feet could cause pilot outage.  
New York, NY 10018  
National Fire Protection Association, Inc.  
Batterymarch Park  
16. Do not operate fireplace if any log is  
broken. Do not operate fireplace if a  
log is chipped (dime-sized or larger).  
PIEZO IGNITION SYSTEM  
This fireplace has a piezo ignitor. This sys-  
tem requires no matches, batteries, or other  
sources to light fireplace.  
Quincy, MA 02269  
17. Provide adequate clearances around air  
openings.  
UNPACKING  
1. Remove log box and fireplace from  
carton. The hood is not attached.  
THERMOSTATIC HEAT  
CONTROL  
This fireplace has a thermostat sensing bulb  
and a control valve. The thermostat will  
automatically modulate the heat output to  
maintain a consistent room temperature.  
This results in greater fireplace comfort.  
This can also result in lower gas bill.  
IMPORTANT: The fireplace hood is  
inside the cardboard protective end  
wrap on the left side of fireplace (as  
viewed from front). A decal is on the  
outside of the cardboard end wrap stat-  
ing hood is enclosed (see Figure 2).  
2. Remove hood from cardboard protec-  
tive end wrap as shown in Figure 2.  
3. Remove all protective packaging ap-  
plied to fireplace for shipment.  
PRODUCT IDENTIFICATION  
Fireplace  
Cabinet  
4. Make sure your fireplace includes one  
hardware packet.  
5. Check fireplace for any shipping  
damage. If fireplace is damaged,  
promptly inform dealer where you  
bought fireplace.  
IMPORTANT:  
THIS PACKAGE CONTAINS A  
Hood  
Screen  
FIREPLACE HOOD. UNWRAP  
CARTON AND REMOVE HOOD  
BEFORE DISCARDING  
PROTECTIVE PACKAGING.  
Enclosed  
Decal  
Cardboard  
Protective  
Fireplace  
End Wrap  
2
Logs  
1
Control Knob  
Ignitor Button  
Hood  
Figure 1 - Vent-Free Natural Gas Fireplace System  
Figure 2 - Removing Fireplace Hood  
107105  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
Log  
Screen  
Shipping  
Screw  
ASSEMBLY  
Shoulder  
Screw  
WARNING: Always have  
branch support and screen in  
place before operating fireplace.  
Thispreventsexcessivetempera-  
tures on fireplace surfaces.  
Burner  
Support  
WARNING: Failure to position  
thepartsinaccordancewiththese  
diagrams or failure to use only  
parts specifically approved with  
this fireplace may result in prop-  
erty damage or personal injury  
ASSEMBLING FIREPLACE  
Tools Required:  
• Phillips screwdriver  
• 5/16" hex wrench  
• slotted screwdriver  
Branch  
Support  
Screen  
Installing Log  
1. Lift screen up and pull out to remove.  
2. Cut two plastic straps to remove the log  
from the firebox cavity.  
Figure 3 - Assembling Fireplace  
3. An optional blower is available. See Ac-  
cessories, page 26. Install optional  
blower now. Follow installation in-  
structions provided with blower.  
4. Gently rotate hood to upright position.  
Make sure hood tabs are behind lou-  
vers and hood is resting on firebox top  
(see Figure 4).  
Assembling Hood  
1. Locate four black phillips sheet metal  
screws from the hardware packet.  
2. Rotate hood as shown in Figure 4.  
Make sure hood tabs point toward  
fireplace.  
4. Remove log packaging material and  
discard packaging. Gently place log set  
on burner support (see Figure 3). The  
log should fit flat against top of burner  
support and log locators fit into the slots  
under the log. Do not allow log to con-  
tact flame. If flame contacts log, soot  
will be created.  
5. Align screw holes on hood with screw  
holes on firebox top.  
6. Insert screws as shown in Figure 4.  
Tighten screws firmly.  
3. Insert hood tabs between baffle and  
louvers (see Figure 4).  
Louver  
Hood  
Hood  
Tabs  
Hood Tab  
5. Reattach screen by placing the notches  
in the screen frame over the shoulder  
screws and pushing down.  
Baffle  
Sheet  
Metal  
Screw  
Firebox Top  
Figure 4 - Assembling Hood  
107105  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Confined and Unconfined Space  
PROVIDING ADEQUATE  
VENTILATION  
AIR FOR  
The National Fuel Gas Code, ANSI Z223.1/  
NFPA54definesaconfinedspaceasaspace  
whose volume is less than 50 cubic feet per  
1,000 Btu per hour (4.8 m3 per kw) of the  
aggregate input rating of all appliances in-  
stalledinthatspaceandanunconfinedspace  
as a space whose volume is not less than 50  
cubic feet per 1,000 Btu per hour (4.8 m3 per  
kw) of the aggregate input rating of all  
appliances installed in that space. Rooms  
communicating directly with the space in  
whichtheappliancesareinstalled*,through  
openings not furnished with doors, are con-  
sidered a part of the unconfined space.  
COMBUSTION AND  
VENTILATION  
The following are excerpts from National  
FuelGasCode, ANSIZ223.1/NFPA54, Sec-  
tion5.3, AirforCombustionandVentilation.  
WARNING: This heater shall  
notbeinstalledinaconfinedspace  
or unusually tight construction  
unless provisions are provided  
foradequatecombustionandven-  
tilation air. Read the following in-  
structions to insure proper fresh  
air for this and other fuel-burning  
appliances in your home.  
All spaces in homes fall into one of the three  
following ventilation classifications:  
1. Unusually Tight Construction  
2. Unconfined Space  
3. Confined Space  
The information on pages 5 through 7 will  
help you classify your space and provide  
adequate ventilation.  
Today’s homes are built more energy effi-  
cient than ever. New materials, increased  
insulation, and new construction methods  
helpreduceheatlossinhomes.Homeowners  
weather strip and caulk around windows and  
doorstokeepthecoldairoutandthewarmair  
in. During heating months, home owners  
want their homes as airtight as possible.  
* Adjoining rooms are communicating only  
iftherearedoorlesspassagewaysorventila-  
tion grills between them.  
Unusually Tight Construction  
The air that leaks around doors and win-  
dows may provide enough fresh air for  
combustion and ventilation. However, in  
buildings of unusually tight construction,  
you must provide additional fresh air.  
Unusually tight construction is de-  
fined as construction where:  
While it is good to make your home energy  
efficient, your home needs to breathe. Fresh  
air must enter your home. All fuel-burning  
appliances need fresh air for proper com-  
bustion and ventilation.  
a. walls and ceilings exposed to the  
outside atmosphere have a con-  
tinuous water vapor retarder with  
a rating of one perm (6 x 10-11 kg  
per pa-sec-m2) or less with open-  
ings gasketed or sealed and  
Exhaustfans, fireplaces, clothesdryers, and  
fuel burning appliances draw air from the  
house to operate. You must provide ad-  
equate fresh air for these appliances. This  
will insure proper venting of vented fuel-  
burning appliances.  
b. weather stripping has been  
added on openable windows and  
doors and  
c. caulking or sealants are applied  
to areas such as joints around  
window and door frames, be-  
tween sole plates and floors, be-  
tween wall-ceiling joints, be-  
tween wall panels, at penetra-  
tions for plumbing, electrical, and  
gas lines, and at other openings.  
If your home meets all of the three  
criteria above, you must provide ad-  
ditional fresh air. See Ventilation Air  
From Outdoors, page 7.  
If your home does not meet all of the  
three criteria above, proceed to De-  
termining Fresh-Air Flow For Fire-  
place Location, page 6.  
Continued  
107105  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
AIR FOR  
COMBUSTION AND  
VENTILATION  
Continued  
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION  
Determining if You Have a Confined or Unconfined Space  
Use this worksheet to determine if you have a confined or unconfined space.  
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills  
between the rooms.  
1. Determine the volume of the space (length x width x height).  
Length x Width x Height = _________________cu. ft. (volume of space)  
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =2560 cu. ft. (volume of space)  
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of  
the space.  
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.  
_____________________(volume of space) x 20 = (Maximum Btu/Hr the space can support)  
Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)  
3. Add the Btu/Hr of all fuel burning appliances in the space.  
Vent-free fireplace  
Gas water heater*  
Gas furnace  
Vented gas heater  
Gas fireplace logs  
__________________Btu/Hr  
__________________Btu/Hr  
__________________Btu/Hr  
__________________Btu/Hr  
__________________Btu/Hr  
Example:  
30,000  
26,000  
56,000  
Gas water heater  
Vent-free fireplace +  
Btu/Hr  
Btu/Hr  
Btu/Hr  
Total  
=
Other gas appliances* + __________________Btu/Hr  
Total = __________________Btu/Hr  
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.  
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.  
_________________ Btu/Hr (maximum the space can support)  
_________________ Btu/Hr (actual amount of Btu/Hr used)  
Example: 51,200 Btu/Hr (maximum the space can support)  
56,000 Btu/Hr (actual amount of Btu/Hr used)  
The space in the above example is a confinedspace because the actual Btu/Hr used is more than the maximum Btu/Hr the space cansupport.  
You must provide additional fresh air. Your options are as follows:  
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-  
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.  
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.  
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.  
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no  
additional fresh air ventilation.  
WARNING:If the area in which the heater may be operated is smaller than that defined as an unconfined space  
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of  
themethodsdescribedintheNationalFuelGasCode,ANSIZ223.1/NFPA54,Section5.3orapplicablelocalcodes.  
107105  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
AIR FOR  
COMBUSTION AND  
VENTILATION  
12"  
Continued  
VENTILATION AIR  
Ventilation Air From Inside  
Building  
Ventilation Grills  
Into Adjoining Room,  
Option 2  
Ventilation  
Grills  
Or  
Thisfreshairwouldcomefromanadjoining  
unconfined space. When ventilating to an  
adjoining unconfined space, you must pro-  
vide two permanent openings: one within  
12" of the ceiling and one within 12" of the  
floor on the wall connecting the two spaces  
(see options 1 and 2, Figure 5). You can also  
remove door into adjoining room (see op-  
tion 3, Figure 5). Follow the National Fuel  
Gas Code, ANSI Z223.1/NFPA 54, Section  
5.3, Air for Combustion and Ventilation for  
required size of ventilation grills or ducts.  
into Adjoining  
Room,  
Option 1  
Remove  
Door into  
Adjoining  
Room,  
Option 3  
12"  
Ventilation Air From Outdoors  
Provide extra fresh air by using ventilation  
grills or ducts. You must provide two per-  
manent openings: one within 12" of the  
ceiling and one within 12" of the floor.  
Connect these items directly to the outdoors  
orspacesopentotheoutdoors.Thesespaces  
include attics and crawl spaces. Follow the  
NationalFuelGasCode,ANSIZ223.1/NFPA  
54, Section 5.3, Air for Combustion and  
Ventilation for required size of ventilation  
grills or ducts.  
Figure 5 - Ventilation Air from Inside Building Shown with Optional Mantel  
Ventilated  
Outlet  
Attic  
Air  
IMPORTANT: Do not provide openings for  
inlet or outlet air into attic if attic has a  
thermostat-controlledpowervent.Heatedair  
enteringtheatticwillactivatethepowervent.  
Outlet  
Air  
To Attic  
To  
Crawl  
Space  
Inlet  
Air  
Ventilated  
Inlet Air  
Crawl Space  
Figure 6 - Ventilation Air from Outdoors Shown with Optional Mantel  
107105  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
CEILING  
Note: Your vent-free fireplace is designed  
to be used in zero clearance installations.  
Wall or framing material can be placed  
directly against any exterior surface on the  
rear, sides, or top of your fireplace, except  
where stand-off spacers are integrally at-  
tached. If standoff spacers are attached to  
your fireplace, these spacers can be placed  
INSTALLATION  
NOTICE: This heater is intended  
foruseassupplementalheat.Use  
this heater along with your pri-  
mary heating system. Do not in-  
stall this heater as your primary  
heat source. If you have a central  
heating system, you may run  
36"  
Minimum  
6"  
Minimum  
From  
Sides Of  
Fireplace  
directly against wall or framing materials.  
systemscirculatingblowerwhile  
using heater. This will help circu-  
late the heat throughout the  
house. In the event of a power  
outage, you can use this heater  
as your primary heat source.  
Use the dimensions shown for rough open-  
ings to create the easiest installation (see  
Built-In Fireplace Installation, page 9).  
Left  
Side  
Right  
Side  
CHECK GAS TYPE  
Use only natural gas. If your gas supply is  
not natural gas, do not install fireplace. Call  
dealerwhereyouboughtfireplaceforproper  
type fireplace.  
FLOOR  
0" Minimum To Top Surface Of Carpeting,  
Tile Or Other Combustible Material  
WARNING: A qualified ser-  
vicepersonmustinstallfireplace.  
Follow all local codes.  
Figure7-MountingClearancesAsViewed  
From Front of Fireplace Shown Built In  
The Wall  
INSTALLATION ITEMS  
Before installing fireplace, make sure you  
have the items listed below.  
CEILING  
WARNING: Never install the  
fireplace  
• piping (check local codes)  
• sealant (resistant to propane/LP gas)  
• equipment shutoff valve *  
• test gauge connection *  
• ground joint union  
• sediment trap  
Top Of  
Mantel Can  
in a bedroom or a bathroom  
in a recreational vehicle  
where curtains, furniture,  
clothing, or other flammable  
objectsarelessthan36inches  
from the front, top, or sides of  
the fireplace  
as a fireplace insert  
in high traffic areas  
in windy or drafty areas  
36"  
Be Flush  
Minimum  
With Wall  
• tee joint  
• pipe wrench  
* ACSAdesign-certifiedequipmentshutoff  
valve with 1/8" NPT tap is an acceptable  
alternative to test gauge connection. Pur-  
chase the optional CSA design-certified  
equipment shutoff valve from your dealer.  
See Accessories, page 26.  
Right  
Side  
Left  
Side  
CAUTION: This fireplace cre-  
ates warm air currents. These  
currents move heat to wall sur-  
faces next to fireplace. Installing  
fireplace next to vinyl or cloth  
wall coverings or operating fire-  
place where impurities (such as,  
butnotlimitedto,tobaccosmoke,  
aromatic candles, cleaning flu-  
ids,oilorkerosenelamps,etc.)in  
the air exist, may discolor walls  
or cause odors.  
Note:Ifdesired,purchaseafour-sidedbrass  
trim kit for built-in installations. See Acces-  
sories, page 26.  
0" Minimum To Top Surface Of Carpeting,  
Tile Or Other Combustible Material  
Figure8-MountingClearancesAsViewed  
From Front of Fireplace Shown with  
Optional Mantel  
LOCATING FIREPLACE  
WARNING:Maintainthemini-  
mum clearances shown in Fig-  
ures 7 and 8. If you can, provide  
greater clearances from floor,  
ceiling, and joining wall.  
Note: When installing fireplace directly on  
carpeting, tile or other combustible material,  
other than wood flooring, the fireplace shall  
beinstalledonametalorwoodpanelextend-  
ing the full width and depth of the fireplace  
IMPORTANT:Vent-freefireplacesaddmois-  
ture to the air. Although this is beneficial,  
installing fireplace in rooms without enough  
ventilationairmaycausemildewtoformfrom  
too much moisture. See Air for Combustion  
and Ventilation, pages 5 through 7.  
You can recess firebox into the wall. You  
can also position fireplace in the optional  
cabinet or corner mantels. IMPORTANT:  
Only use optional cabinet or corner mantels  
specified in this manual. Purchase the op-  
tional mantel from your dealer (see Acces-  
sories, page 26).  
CAUTION: If you install the  
fireplace in a home garage  
fireplace pilot and burner must  
beatleast18inchesabovefloor.  
locate fireplace where moving  
vehicle will not hit it.  
107105  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
9. Check all gas connections for leaks. See  
INSTALLATION  
WARNING: If pre-wiring, do  
not connect wiring to any electri-  
cal source at this time.  
Checking Gas Connections, page 16.  
Continued  
10. If using optional brass trim kit, install  
the trim after final finishing and/or  
painting of wall. See instructions in-  
cluded with brass trim accessory for at-  
taching brass trim.  
For convenience and efficiency, install  
fireplace  
Install fireplace electrical outlet  
and connect wiring to outlet be-  
fore connecting to electrical  
source. The fireplace electrical  
outlet is included with the  
GA3450(T) blower accessory.  
• where there is easy access for operation,  
inspection, and service.  
IMPORTANT: When finishing your fire-  
box,combustiblematerialssuchaswallboard,  
gypsumboard,sheetrock,drywall,plywood,  
etc. maybebuttedupnexttothesidesandtop  
of the firebox. Combustible materials should  
never overlap the firebox front facing.  
• in coldest part of room.  
An optional blower kit is available from  
your dealer. See Accessories, page 26. If  
planningtouseblower,locatefireplacenear  
an electrical outlet.  
Only use the fireplace electrical  
outlet supplied with the  
GA3450(T) blower accessory.  
BUILT-IN FIREPLACE  
INSTALLATION  
Note:Aqualified installer should make  
all electrical connections.  
WARNING: Do not allow any  
combustiblematerialstooverlap  
the firebox front facing.  
3. Install gas piping to fireplace location.  
This installation includes an approved  
flexible gas line (if allowed by local  
codes) after the equipment shutoff  
valve. The flexible gas line must be the  
last item installed on the gas piping.  
Built-ininstallationofthisfireplaceinvolves  
installing fireplace into a framed-in enclo-  
sure. This makes the front of fireplace flush  
with wall. An optional brass trim kit acces-  
sory is available (see Accessories, page 26).  
Brasstrimwillextendpastsidesoffireplace  
approximately 1/2 inch. This will cover the  
rough edges of the wall opening. If install-  
ingabuilt-inmantelabovethefireplaceyou  
must follow the clearances shown in Figure  
12, page 10. Follow the instructions below  
to install the fireplace in this manner.  
IMPORTANT: Noncombustible materials  
such as brick, tile, etc. may overlap the front  
facing, but should never cover any neces-  
sary openings like louvered slots.  
4. If you have not assembled firebox, fol-  
low instructions on page 4.  
WARNING: Do not allow non-  
combustible materials to cover  
any necessary openings like lou-  
vered slots.  
5. Carefully set fireplace in front of rough  
opening with back of fireplace inside  
wall opening.  
6. Attach flexible gas line to fireplace gas  
regulator. See Connecting Fireplace to  
Gas Supply, page 15.  
Actual Framing  
WARNING: Never modify or  
cover the louvered slots on the  
front of the firebox.  
Height  
26"  
26 3/4"  
9 1/2"  
3/4"  
26 7/8"  
26 7/8"  
10 1/2"  
3/4"  
7. Bend four nailing flanges on outer cas-  
ing with pliers (see Figure 11).  
Front Width  
Depth  
8. Attach fireplace to wall studs using  
nails or wood screws through holes in  
nailing flange.  
WARNING: Use only noncom-  
bustiblemortaroradhesiveswhen  
overlapping the front facing with  
noncombustible facing material.  
Bottom  
1. Frame in rough opening. Use dimen-  
sions shown in Figure 9 for the rough  
opening.  
If installing in a corner, use dimensions  
shown in Figure 10 for the rough open-  
ing. The height is 26 7/8" which is the  
same as the wall opening above.  
10 1  
/2"  
Nails or  
Wood  
Screws  
267  
/8"  
3/4" Off  
2. If installing GA3450(T) blower acces-  
sory, do so at this time. Follow instruc-  
tions included with blower accessory.  
The Floor  
Minimum  
267  
/8"  
Figure9-RoughOpeningforInstallingin  
Wall  
Note: If not installing blower acces-  
sory, you may wish to run electrical  
wiring to your fireplace for future  
blower installation (see Accessories,  
page 26) Use only approved three-wire  
electrical wiring.  
365  
/
8"  
257  
/
8
"
Nailing  
Flanges  
267  
513  
/
8
"
/
4
"
Figure 10 - Rough Opening for Installing  
in Corner  
Figure11-AttachingFireplacetoWallStuds  
Continued  
107105  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
3. Place mantel around fireplace/base 12. Check for leaks. See Checking Gas  
INSTALLATION  
assembly.  
4. Assemble brass trim kit. See Assem- 13. Place mantel around fireplace. Be care-  
bling Brass Trim, page 11. ful not to damage wall or mantel.  
5. Firmly snap brass trim kit on shoulder 14. Place brass trim kit on the shoulder  
Connections, page 16.  
Continued  
Mantel Clearances for Built-In  
Installation  
If placing mantel above built-in fireplace,  
youmustmeetminimumclearancebetween  
mantel shelf and top of fireplace opening.  
screws. Shoulder screws are located on  
fireplace cabinet (see Figure 13).  
screws located on the side and top of  
the fireplace. Firmly snap the brass trim  
over the shoulder screws on fireplace  
(see Figure 13).  
6. Align brass trim kit for flush fit around  
opening.  
NOTICE:Surfacetemperaturesof  
adjacent walls and mantels be-  
comehotduringoperation.Walls  
and mantels above the firebox  
may become hot to the touch. If  
installedproperly,thesetempera-  
turesmeettherequirementofthe  
national product standard. Fol-  
low all minimum clearances  
shown in this manual.  
15. Adjust assembly to remove any gaps.  
Attach remaining two 3" wood screws  
from hardware pack through openings  
inside of fireplace sides into the man-  
tel. The openings are located at top be-  
hind the area for the black louvers (see  
Figure 13).  
7. Use two 3" wood screws provided and  
attach fireplace base to wooden base  
(see Figure 13).  
8. Remove brass trim kit and mantel. Be  
careful not to damage wall or mantel.  
9. Place wood base next to wall at instal-  
lation location.  
16. Reinstall top black louvers.  
10. Attach wood base to floor with two 1 3/4"  
black screws provided (see Figure 14).  
If the floor is concrete use anchor method  
(see AttachingWood Base to Solid Floor,  
page 14).  
Hole for 3"  
wood screw  
Shoulder  
Screws  
for attaching  
fireplace to  
mantel  
NOTICE: If your installation does  
notmeettheminimumclearances  
shown, you must do one of the  
following:  
11. Install gas line. See Connecting To Gas  
Supply, page 14.  
Mantel Shelf  
raise the mantel to an accept-  
able height  
remove the mantel  
10"  
Note:  
All vertical  
8"  
measurements  
are from top of  
fireplace  
6"  
2 1/2  
OPTIONAL MANTEL  
INSTALLATION  
"
opening to  
Note: Refer to instructions provided with  
the mantel for assembly instructions. Refer  
to instructions below for system installa-  
tion. Refer to instructions on page 4 for  
firebox assembly. Blower accessory should  
be installed if it is being used (see Accesso-  
ries, page 26).  
bottom of  
Hole for 3"  
mantel shelf. All  
measurements  
are in inches.  
wood screw  
for attaching  
fireplace to  
wooden base  
Assembled  
Brass Trim  
Side of  
Firebox  
Figure 13 - Attaching Brass Trim to  
Fireplace  
1. Unscrew four brass screws that attach  
top louver to fireplace. Remove louver  
from fireplace and set aside.  
1 3/4" Screw  
2. Place fireplace on wood base.  
Wood Base  
Figure 12 - Minimum Mantel Clearances  
for Built-In Installation  
Figure 14 - Attaching Wood Base to Floor  
107105  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Branch  
Support  
INSTALLING BLOWER  
ACCESSORY GA3450T  
INSTALLATION  
Shoulder  
Screw  
Continued  
Removing Upper Louver  
Assembly  
Assembling Brass Trim (Brass  
trim shipped with mantel)  
Remove  
Screw  
1. Remove packaging from three remain-  
ing pieces of brass trim.  
To install the blower accessory, you must  
first remove the upper louver assembly.  
Valve  
Cover  
Shield  
2. Locate two adjusting plates with set 1. Lift screen off heater.  
screws, and two shims in the hardware  
2. Remove 4 screws from louver assem-  
2
packet.  
bly (see Figure 16). Save these screws.  
3. Align shim under adjusting plate as  
shown in Figure 15.  
3. Pull louver assembly straight out from  
the cabinet. Be careful not to scratch  
the paint. Set louver assembly and  
4. Slide one end of adjusting plate/shim  
in slot on mitered edge of top brass trim  
(see Figure 15).  
screws aside.  
1
Blower Bracket  
Mounting Holes  
5. Slide other end of adjusting plate/shim  
in slot on mitered edge of side brass  
trim (see Figure 15).  
Bottom Louver  
Assembly  
Snap  
Bushings  
6. While firmly holding edges of brass  
trim together, tighten both set screws  
on the adjusting plate with slotted  
screwdriver.  
Figure 17 - Removing Valve Cover Shield  
Installing Blower Assembly  
7. Repeat steps 1 through 6 for other corner.  
Upper Louver  
Assembly  
CAUTION: Label all wires  
priortodisconnectionwhenser-  
vicing controls. Wiring errors  
can cause improper and danger-  
ous operation.  
8. Set brass assembly aside for later in-  
stallation.  
Brass Screws  
Top Brass  
Figure 16 - Removing Upper Louver  
Assembly  
Trim  
Set  
Screws  
Slot  
Removing Valve Cover Shield  
CAUTION: Verify proper op-  
eration after servicing.  
1. Open bottom louver assembly by  
swinging the assembly down (see Fig-  
ure 17).  
Mitered  
Edge  
Note: If you are using a mantel with your  
heater, use the following instructions. If  
your heater is built-in, see For Built-In In-  
stallation on page 13.  
Shim  
2. Using short Phillips screwdriver, re-  
move the screw under the center of the  
branch support. Rotate valve cover  
shield clockwise and slide out.  
IMPORTANT: Do not remove shoul-  
der screw on the left side of valve cover  
shield. Slide the valve cover shield off  
of the shoulder screw (see Figure 17).  
Side Brass  
Trim  
Adjusting  
Plate  
1. Install snap bushings found in hardware  
kit into both holes in rear of valve cover  
shield.  
Slot  
2. Make sure the wire harness is firmly  
connected to the terminals on the blower  
bracket assembly.  
Note: If you do not have a short  
Phillips screwdriver, the screen, twigs,  
and branch support must be removed  
so a longer screwdriver may be used.  
See Connecting Fireplace To Gas Sup-  
ply, page 15 and follow step 2.  
Figure 15 - Assembling Brass Trim  
3. Note the wire locations on back of  
AUTO/OFF/ON switch. The terminals  
on back of switch are numbered 1, 2,  
and 3. Carefully remove red wire from  
terminal 1 and blue wire from terminal  
3. Black wire can remain on middle  
terminal 2 (see Figure 18, page 12).  
Continued  
107105  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
6. Route the wire harness through the 9. Install the switch plate on the valve  
INSTALLATION  
hole in left side of baffle. Pull wire  
harness through lower opening above  
where the valve shield was removed.  
(see Figure 18).  
cover shield with 2 #10 screws provided  
(see Figure 19). Reinstall the valve  
cover shield. Route power cord out of  
the cabinet by inserting it through the  
bushing on the outer casing (see Fig-  
ure 18). Plug fan kit into 120-Volt  
grounded power supply and test opera-  
tion. Note: When switch is in the  
AUTO position, the fan will start after  
the heater has run for a few moments.  
The fan will continue to run for sev-  
eral moments after the heater has been  
turned off. When switch is in the ON  
position, the fan will run until turned  
to OFF. Reinstall upper louver assem-  
bly and hood if previously removed,  
(see Figure 16, page 11). Close lower  
louver door.  
Continued  
4. Carefully disconnect green and white  
wires at their insulated connectors.  
7. Insert the 4 wire harness into one of the  
round holes in the rear of the valve cover  
shield and through the rectangular hole  
in the front of shield (see Figure 18).  
5. In top of the heater cabinet, locate the  
four mounting holes on the outer cas-  
ing. Align these four holes with those  
on the blower bracket assembly. Attach  
blower bracket assembly to the outer  
casing with 4 #10 screws provided (see  
Figure 18).  
8. Reconnect red wire to switch position  
3. Reconnect blue wire to switch posi-  
tion 1. Reconnect green and white wires.  
Wiring Routing  
Hole in Baffle  
Blower Bracket  
Assembly  
Screw  
Baffle  
Valve Cover  
Shield  
Wire  
Harness  
Switch  
Switch  
Plate  
Power  
Cord  
Screw  
3
2
1
Figure19-InstallingSwitchPlatetoValve  
Cover Shield  
Red  
Blue  
Switch  
Plate  
Wire  
Harness  
Valve Cover  
Shield  
Box Cover  
Figure 18 - Installing Blower Bracket Assembly  
107105  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Fan Switch  
INSTALLATION  
(Auto/Off/On)  
Auto  
1
Continued  
2
Off  
3
Thermostat  
Switch  
(N.O.)  
Blue  
For Built-In Installation  
On  
WARNING: A licensed elec-  
trician must connect the wiring  
harness to electrical supply fol-  
lowing all local codes. Electri-  
cian must provide a clamp on  
the box cover to secure the wir-  
ing. Wiring should be routed  
through the bushing in the hole  
on the outer casing of heater.  
Blue  
110/115  
V.A.C.  
Red  
Blower  
Motor  
Black  
Red  
White  
Green  
White  
Green  
Figure 20 - Wiring Diagram For Blower Accessory Built-In Installation  
Follow instructions Removing Valve Cover  
Shield (page 11), then  
Blower Bracket  
Assembly  
1. Install a snap bushing found in hardware  
kit into one of the holes found on rear of  
valve cover shield. The other hole is for  
a strain relief clamp (not supplied) to  
secure incoming electrical supply.  
Screw  
2. Follow steps 2 through 6 in Installing  
Blower Assembly, pages 11 and 12.  
Also remove black wire from middle  
switch terminal 2.  
3. Remove black plastic strain relief and  
power cord from switch plate. The  
power cord supplied will not be used in  
built-in installations. Pop in the plastic  
snap bushing found in hardware kit into  
the hole left by supply cord/strain relief.  
Switch  
Wire  
Harness  
Power  
Cord  
Outlet  
Receptacle  
3
2
1
4. A licensed electrician must follow the  
wiring diagram to connect incoming  
electrical supply to fan kit wiring har-  
ness (see Figure 20).  
Red  
Blue  
5. Plug power cord to the outlet receptacle  
(not provided) as shown in Figure 21.  
Wind the extra cable in power cord and  
and tie it up with the plastic wire strap  
(see Figure 21). Set the cable bundle  
between the burner bracket and outer  
casing, away from the burner.  
Switch Plate  
Plastic Wire  
Strap  
Valve  
Cover  
Shield  
6. Reinstall valve cover shield.  
Box Cover  
Wire  
7. Test to make sure the blower is work-  
ing properly.  
Harness  
Clamp Connector  
(not included)  
8. Reinstall upper louver assembly and  
hood if previously removed, (see Figure  
16, page 11). Close lower louver door.  
Figure 21 - Installing Blower Bracket Assembly  
Continued  
107105  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
CONNECTING TO GAS  
INSTALLATION  
CAUTION:Use only new,  
SUPPLY  
Continued  
black iron or steel pipe. Inter-  
nally-tinned copper tubing may  
be used in certain areas. Check  
your local codes. Use pipe of  
1/2" or greater diameter to al-  
low proper gas volume to fire-  
place. If pipe is toovolumepres-  
sure will occur.  
WARNING: This appliance re-  
quires a 45° male flare fitting 5/8"-  
18 UNF (Unified National Fine  
Thread) inlet connection and the  
flexible gas line provided.  
Extension Cord  
Use extension cord if needed. The cord must  
have a three-prong, grounding plug and a  
three-hole receptacle. Make sure cord is in  
good shape. It must be heavy enough to carry  
the current needed. An undersized cord will  
cause a drop in line voltage. This will result  
in loss of power and overheating. Use a No.  
16 AWG cord for lengths less than 50 feet.  
WARNING: A qualified ser-  
vice person must connect fire-  
place to gas supply. Follow all  
local codes.  
Installation must include an equipment  
shutoff valve, union, and plugged 1/8" NPT  
tap. Locate NPT tap within reach for test  
gauge hook up. NPT tap must be upstream  
from fireplace (see Figure 23).  
Attaching Wood Base to Solid  
Floor  
IMPORTANT: Install main gas valve  
(equipment shutoff valve) in an accessible  
location. The main gas valve is for turning  
on or shutting off the gas to the appliance.  
WARNING: Never connect  
fireplace to private (non-utility)  
gas wells. This gas is commonly  
known as wellhead gas.  
For attaching base to solid floors (concrete  
or masonry)  
Note: Floor anchors and mounting screws  
are in hardware package. The hardware  
package is provided with fireplace.  
Check your building codes for any special  
requirementsforlocatingequipmentshutoff  
valve to fireplaces.  
IMPORTANT: Check gas line pressure be-  
fore connecting fireplace to gas line. Gas  
line pressure must be no greater than 14  
1. Drill holes at marked locations using  
5/16" drill bit. For solid floors (con- inchesofwater.Ifgaslinepressureishigher,  
crete or masonry), drill at least 1" deep. fireplace regulator damage could occur.  
ApplypipejointsealantlightlytomaleNPT  
threads. This will prevent excess sealant  
from going into pipe. Excess sealant in pipe  
could result in clogged fireplace valves.  
2. Fold floor anchor as shown in Figure 22.  
CSA Design-Certified  
3. Insert floor anchor (wings first) into  
hole. Tap anchor flush to floor.  
Equipment Shutoff Valve  
With 1/8" NPT Tap*  
CAUTION:Usepipejointseal-  
ant that is resistant to liquid pe-  
troleum (LP) gas.  
4. Insert mounting screws through base  
and into floor anchors.  
5. Tighten screws until base is firmly fas-  
tened to floor.  
We recommend that you install a sediment  
trap in supply line as shown in Figure 23.  
Locate sediment trap where it is within  
reach for cleaning. Install in piping system  
betweenfuelsupplyandheater.Locatesedi-  
ment trap where trapped matter is not likely  
to freeze. A sediment trap traps moisture  
and contaminants. This keeps them from  
going into fireplace controls. If sediment  
trap is not installed or is installed wrong,  
fireplace may not run properly.  
From Gas  
Meter (5"  
W.C. to  
10.5" W.C.  
Pressure)  
3" Minimum  
Cap Pipe Tee  
Figure 22 - Folding Anchor  
Nipple Joint  
Sediment Trap  
Figure 23 - Gas Connection  
* Purchase the optional CSA design-certified  
equipment shutoff valve from your dealer. See  
Accessories, page 26.  
107105  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
5. Check all gas connections for leaks. See  
INSTALLATION  
CAUTION: Avoid damage to  
Checking Gas Connections, page 16.  
Continued  
regulator.Holdgasregulatorwith  
wrenchwhenconnectingittogas  
piping and/or fittings.  
6. Replace branch support back into fire-  
place. Feed flexible gas line into fire-  
place base area while replacing branch  
support. Make sure the entire flexible  
gas line is in fireplace base area. Reat-  
tach branch support to fireplace with  
screws removed in step 2.  
CONNECTING EQUIPMENT  
SHUTOFF VALVE TO  
HEATER CONTROL  
4. Apply pipe joint sealant lightly to male  
threads of gas connector attached to  
flexible gas line/equipment shutoff  
valve (see Figure 25).  
Installation Items Needed  
• Phillips screwdriver  
• sealant (resistant to propane/LP gas, not  
provided)  
Screen  
Shipping  
Screw  
1. Remove fireplace screen. Remove two  
screws that hold fireplace screen in  
place for shipping. These screws are  
located near top of screen. Discard  
screws. Lift fireplace screen up and pull  
out to remove.  
Branch  
Support  
Shoulder  
Screw  
2. Remove screws that attach branch sup-  
port to fireplace (see Figure 24). Care-  
fully lift up branch support and remove  
from fireplace (see Figure 24).  
Flexible  
Gas Line  
3. Route flexible gas line, included, from  
fireplace control to equipment shutoff  
valve through side or rear access holes  
in outer casing.  
NOTICE: Most building codes do  
not permit concealed gas con-  
nections. A flexible gas line is  
provided to allow accessibility  
fromthefireplace(seeFigure25).  
The flexible gas supply line con-  
nection to the equipment shutoff  
valve should be accessible.  
Screen  
Figure 24 - Removing Branch Support From Fireplace  
To Fireplace  
Gas Regulator  
Equipment Shutoff Valve  
Provided by Installer  
Flexible Gas Line from  
Fireplace Gas Regulator  
To External  
Regulator  
Figure 25 - Attaching Flexible Gas Line to Equipment Shutoff Valve  
Continued  
107105  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
Test Pressures Equal To or Less Than  
1/2 PSIG (3.5 kPa)  
Pressure Testing Fireplace Gas  
Connections  
1. Open equipment shutoff valve (see Fig-  
INSTALLATION  
Continued  
1. Close equipment shutoff valve (see Fig-  
ure 26).  
ure 26).  
CHECKING GAS  
CONNECTIONS  
2. Pressurize supply piping system by either  
2. Open main gas valve located on or near  
gas meter.  
using compressed air or opening main gas  
valve located on or near gas meter.  
3. Make sure control knob of fireplace is  
in the OFF position.  
WARNING: Test all gas pip-  
3. Check all joints from gas meter to equip-  
ment shutoff valve (see Figure 27).Apply  
a noncorrosive leak detection fluid to gas  
joints. Bubbles forming show a leak.  
ing and connections for leaks  
after installing or servicing. Cor-  
rect all leaks at once.  
4. Check all joints from equipment shutoff  
valve to thermostat gas valve (see Fig-  
ure 27). Apply a noncorrosive leak de-  
tection fluid to gas joints. Bubbles  
forming show a leak.  
4. Correct all leaks at once.  
WARNING:Neveruseanopen  
flame to check for a leak. Apply a  
noncorrosiveleakdetectionfluid  
toalljoints.Bubblesformingshow  
a leak. Correct all leaks at once.  
5. Correct all leaks at once.  
Open  
Equipment  
Shutoff  
Valve  
6. Light fireplace (see Operating Fire-  
place, pages 17 and 18). Check all other  
internal joints for leaks.  
7. Turn off fireplace (see To Turn Off Gas  
to Appliance, page 18).  
Pressure Testing Gas Supply  
Piping System  
O
Closed  
8. Replace front panel.  
Test Pressures In Excess Of 1/2 PSIG  
(3.5 kPa)  
Figure 26 - Equipment Shutoff Valve  
1. Disconnect appliance with its appliance  
main gas valve (control valve) and equip-  
ment shutoff valve from gas supply pip-  
ing system. Pressures in excess of 1/2  
psig will damage fireplace regulator.  
Equipment  
Shutoff  
Valve  
2. Cap off open end of gas pipe where  
equipment shutoff valve was connected.  
Gas Meter  
3. Pressurize supply piping system by either  
using compressed air or opening main gas  
valve located on or near gas meter.  
4. Check all joints of gas supply piping  
system. Apply a noncorrosive leak de-  
tection fluid to gas joints. Bubbles  
forming show a leak.  
5. Correct all leaks at once.  
6. Reconnect heater and equipment  
shutoff valve to gas supply. Check re-  
connected fittings for leaks.  
Figure 27 - Checking Gas Joints  
107105  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Note: You may be running this fire-  
place for the first time after hooking  
up to gas supply. If so, the control  
knob may need to be pressed in for  
30 seconds or more. This will allow  
air to bleed from the gas system.  
• If control knob does not pop up  
when released, contact a qualified  
service person or gas supplier for  
repairs.  
LIGHTING  
INSTRUCTIONS  
OPERATING  
FIREPLACE  
WARNING: You must operate  
this fireplace with the fireplace  
screen in place. Make sure fire-  
place screen is installed before  
running fireplace.  
FOR YOUR SAFETY  
READ BEFORE  
LIGHTING  
WARNING: If you do not fol-  
low these instructions exactly, a  
fireorexplosionmayresultcaus-  
ing property damage, personal  
injury or loss of life.  
NOTICE: During initial operation  
of new fireplace, burning logs  
will give off a paper-burning  
smell. Orange flame will also be  
present. Open window to vent  
smell. Operate fireplace on HI  
position to burn off odor. This  
will only last a few hours.  
6. With control knob pressed in, push  
down and release ignitor button.  
This will light pilot. The pilot is at-  
tached to the front of burner. If  
needed, keep pressing ignitor but-  
ton until pilot lights.  
A. This appliance has a pilot which must  
be lighted by hand. When lighting the  
pilot, follow these instructions exactly.  
Note: If pilot does not stay lit, refer  
to Troubleshooting, pages 20 through  
22. Also contact a qualified service  
person or gas supplier for repairs.  
Until repairs are made, light pilot with  
match. To light pilot with match, see  
Manual Lighting Procedure, page 18.  
B. BEFORE LIGHTING smell all  
around the appliance area for gas. Be  
sure to smell next to the floor because  
some gas is heavier than air and will  
settle on the floor.  
1. STOP! Read the safety information,  
column 1.  
2. Make sure equipment shutoff valve  
is fully open.  
3. Turn control knob clockwise  
to the OFF position.  
WHAT TO DO IF YOU SMELL  
GAS  
7. Keep control knob pressed in for 30  
seconds after lighting pilot. After 30  
seconds, release control knob.  
• Do not try to light any appliance.  
• Do not touch any electric switch; do  
not use any phone in your building.  
• Immediately call your gas supplier  
from a neighbor’s phone. Follow  
the gas supplier’s instructions.  
• If you cannot reach your gas sup-  
plier, call the fire department.  
4. Wait five (5) minutes to clear out any  
gas.Then smell for gas, including near  
the floor. If you smell gas, STOP! Fol-  
low “B” in the safety information,  
column 1. If you don’t smell gas, go  
to the next step.  
Note: If pilot goes out, repeat steps  
3 through 7. This fireplace has a  
safety interlock system. Wait one (1)  
minute before lighting pilot again.  
8. Turn control knob counterclockwise  
to desired heating level. The  
main burner should light. Set control  
knob to any heat level between HI  
and LO.  
5. Turn control knob counterclockwise  
the PILOT position. Press  
in control knob for five (5) seconds  
(see Figure 28).  
C. Use only your hand to push in or turn  
the gas control knob. Never use tools.  
If the knob will not push in or turn  
by hand, don’t try to repair it, call a  
qualified service technician or gas  
supplier. Force or attempted repair  
may result in a fire or explosion.  
Control Knob  
Ignitor Button  
CAUTION:Donottrytoadjust  
heatinglevelsbyusingtheequip-  
ment shutoff valve.  
D. Do not use this appliance if any part  
has been under water. Immediately call  
a qualified service technician to inspect  
the appliance and to replace any part  
of the control system and any gas con-  
trol which has been under water.  
Thermocouple  
Ignitor Electrode  
Pilot Burner  
Figure 28 - Control Knob In The OFF  
Position  
Figure 29 - Pilot  
Continued  
107105  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
MANUAL LIGHTING  
PROCEDURE  
1. Follow steps 1 through 5 under Light-  
OPERATING  
INSPECTING  
BURNER  
FIREPLACE  
Continued  
ing Instructions, page 17.  
Check pilot flame pattern and burner flame  
pattern often.  
2. With control knob pressed in, strike  
match. Hold match to pilot until pi-  
lot lights.  
TO TURN OFF GAS  
TO APPLIANCE  
Shutting Off Fireplace  
1. Turn control knob clockwise  
to the OFF position.  
PILOT FLAME PATTERN  
Figure31showsacorrectpilotflamepattern.  
Figure 32 shows an incorrect pilot flame  
pattern. Theincorrectpilotflameisnotprop-  
erlyheatingthethermocouple.Thiswillcause  
the thermocouple to cool. When the thermo-  
couple cools, the fireplace will shut down.  
3. Keep control knob pressed in for 30  
seconds after lighting pilot. After 30  
seconds, release control knob. Now  
follow step 8, page 17.  
2. Turn off all electric power to the ap-  
pliance if service is to be performed.  
Shutting Off Burner Only (pilot  
stays lit)  
OPERATING BLOWER  
If pilot flame pattern is incorrect, as shown  
in Figure 32  
This blower has three settings: ON, OFF,  
andAUTO.IntheONposition,theblower  
will operate constantly. In the OFF posi-  
tion, the blower will not operate. In the  
AUTOposition,theblowerwillstartwhen  
thethermostatsensesasufficientincrease  
in firebox temperature.  
Turn control knob clockwise  
the PILOT position.  
to  
• turn fireplace off (see To Turn Off Gas to  
Appliance)  
THERMOSTAT  
CONTROL OPERATION  
• see Troubleshooting, pages 20 through 22  
Note: The pilot flame on natural gas units  
will have a slight curve, but flame should be  
blue and have no yellow or orange color.  
The thermostatic control used on this fire-  
place differs from standard thermostats.  
Standard thermostats simply turn on and  
off the burner. The thermostat used on  
this fireplace senses the room tempera-  
ture. The thermostat adjusts the amount  
of gas flow to the burner. This increases or  
decreasestheburnerflameheight.Attimes  
the room may exceed the set temperature.  
If so, the burner will shut off. The burner  
willcyclebackonwhenroomtemperature  
drops below the set temperature.  
Note: Your fireplace and thermostat  
blower will not turn on and off at the  
same time. The fireplace may run for  
several minutes before the blower turns  
on.Aftertheheatermodulatestothepilot  
position, the blower will continue to run.  
The blower will shut off after the firebox  
temperature decreases.  
Thermocouple  
Pilot Burner  
Note: It is safe to operate fireplace with  
blower turned off. However, the blower  
helps distribute heated air from the  
fireplace.  
The control knob can be set to any heat  
level between HI and LO.  
Figure 31 - Correct Pilot Flame Pattern  
Auto/Off/On Switch  
Note: The thermostat sensing bulb mea-  
sures the temperature of air near the  
fireplace cabinet. This may not always  
agree with room temperature (depend-  
ing on housing construction, installation  
location, room size, open air tempera-  
tures, etc.). Frequent use of your fire-  
place will let you determine your own  
comfort levels.  
Thermocouple  
Pilot Burner  
O
N
OFF  
Figure 32 - Incorrect Pilot Flame Pattern  
Figure 30 - Auto/Off/On Switch  
107105  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
4. Check the injector holder located at the  
INSPECTING  
CLEANING AND  
end of the burner tube again. Remove  
any large particles of dust, dirt, lint, or  
pet hair with a soft cloth or vacuum  
cleaner nozzle.  
BURNER  
MAINTENANCE  
Continued  
WARNING: Turn off fireplace  
and let cool before cleaning.  
BURNER FLAME PATTERN  
5. Blow air into the primary air holes on  
the injector holder.  
Figure 33 shows a correct burner flame  
pattern.Figure34showsanincorrectburner  
flame pattern. The incorrect burner flame  
pattern shows sporadic, irregular flame tip-  
ping. The flame should not be dark or have  
an orange/reddish tinge.  
6. In case any large clumps of dust have  
now been pushed into the burner repeat  
steps 3 and 4.  
CAUTION:Youmustkeepcon-  
trol areas, burner, and circulating  
air passageways of fireplace  
clean. Inspect these areas of fire-  
place before each use. Have fire-  
place inspected yearly by a quali-  
fiedserviceperson.Fireplacemay  
need more frequent cleaning due  
to excessive lint from carpeting,  
pet hair, bedding material, etc.  
Clean the pilot assembly also. A yellow tip  
on the pilot flame indicates dust and dirt in  
the pilot assembly. There is a small pilot air  
inlet hole about two inches from where the  
pilot flame comes out of the pilot assembly  
(see Figure 36). With the unit off, lightly  
blow air through the air inlet hole. You may  
blowthroughadrinkingstrawifcompressed  
air is not available.  
Note: When using the fireplace the first  
time, the flame will be orange for approxi-  
mately one hour until the log cures.  
Ifburnerflamepatternisincorrect,asshown  
in Figure 34  
• turn fireplace off (see To Turn Off Gas to  
Appliance, page 18)  
CLEANING BURNER  
INJECTOR HOLDER AND  
PILOT AIR INLET HOLE  
Injector Holder  
• see Troubleshooting, pages 20 through 22  
The primary air inlet holes allow the proper  
amount of air to mix with the gas. This pro-  
videsacleanburningflame. Keeptheseholes  
clear of dust, dirt, lint, and pet hair. Clean  
these air inlet holes prior to each heating  
season.Blockedairholeswillcreatesoot.We  
recommendthatyoucleantheuniteverythree  
months during operation and have heater in-  
spected yearly by a qualified service person.  
Ports/Slots  
Burner  
Tube  
Figure 33 - Correct Burner Flame Pattern  
Primary Air Inlet  
Holes  
Figure 35 - Injector Holder On Outlet  
Burner Tube  
Wealsorecommendthatyoukeeptheburner  
tube and pilot assembly clean and free of  
dustanddirt.Tocleanthesepartswerecom-  
mend using compressed air no greater than  
30 PSI. Your local computer store, hard-  
ware store, or home center may carry com-  
pressed air in a can. You can use a vacuum  
cleaner in the blow position. If using com-  
pressed air in a can, please follow the direc-  
tions on the can. If you don't follow direc-  
tionsonthe can, youcoulddamage the pilot  
assembly.  
Pilot Air  
Inlet Hole  
Figure34-IncorrectBurnerFlamePattern  
Figure 36 - Pilot Inlet Air Hole  
1. Shut off the unit, including the pilot.  
Allow the unit to cool for at least thirty  
minutes.  
CABINET  
Air Passageways  
2. Inspect burner, pilot, and primary air  
inlet holes on injector holder for dust  
and dirt (see Figure 35).  
• Use a vacuum cleaner or pressurized air  
to clean.  
Exterior  
3. Blow air through the ports/slots and  
holes in the burner.  
• Use a soft cloth dampened with a mild  
soap and water mixture. Wipe the cabi-  
net to remove dust.  
107105  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
TROUBLESHOOTING  
Note: For additional help, visit DESA  
International’stechnicalservicewebsite  
WARNING: Turn off and un-  
plug fireplace and let cool before  
servicing. Only a qualified ser-  
vice person should service and  
repair fireplace.  
CAUTION: Never use a wire,  
needle, or similar object to clean  
ODS/pilot.ThiscandamageODS/  
pilot unit.  
Note:Alltroubleshootingitemsarelistedin  
order of operation.  
OBSERVED PROBLEM  
POSSIBLE CAUSE  
REMEDY  
When ignitor button is pressed, there is no 1. Ignitor cable pinched or wet  
spark at ODS/pilot  
1. Free ignitor cable if pinched by any  
metal or tubing. Keep ignitor cable dry  
2. Ignitor electrode not connected to igni- 2. Reconnect ignitor cable  
tor cable  
3. Broken ignitor cable  
4. Bad piezo ignitor  
5. Ignitor electrode broken  
6. Ignitor electrode positioned wrong  
3. Replace ignitor cable  
4. Replace piezo ignitor  
5. Replace pilot assembly  
6. Replace pilot assembly  
When ignitor button is pressed, there is 1. Gas supply turned off or equipment 1. Turn on gas supply or open equipment  
spark at ODS/pilot but no ignition  
shutoff valve closed  
shutoff valve  
2. Control knob not in PILOT position  
2. Turn control knob to PILOT position  
3. Control knob not pressed in while in 3. Press in control knob while in PILOT  
PILOT position  
position  
4. Air in gas lines when installed  
4. Continue holding down control knob. Re-  
peat igniting operation until air is removed  
5. Clean ODS/pilot (see Cleaning and  
Maintenance, page 19) or replace ODS/  
pilot assembly  
5. ODS/pilot is clogged  
6. Gas regulator setting is not correct  
6. Replace gas regulator  
ODS/pilot lights but flame goes out when 1. Control knob not fully pressed in  
1. Press in control knob fully  
control knob is released  
2. Control knob not pressed in long enough 2. After ODS/pilot lights, keep control  
knob pressed in 30 seconds  
3. Safety interlock system has been triggered 3. Wait one minute for safety interlock sys-  
tem to reset. Repeat ignition operation  
4. Equipment shutoff valve not fully open 4. Fully open equipment shutoff valve  
5. Thermocouple connection loose at con- 5. Hand tighten until snug, then tighten 1/4  
trol valve  
turn more  
6. Pilot flame not touching thermocouple, 6. A) Contact local natural gas company  
which allows thermocouple to cool,  
causing pilot flame to go out. This prob-  
lem could be caused by one or both of  
the following:  
B) Clean ODS/pilot (see Cleaning and  
Maintenance, page 19) or replace ODS/  
pilot assembly  
A) Low gas pressure  
B) Dirty or partially clogged ODS/pilot  
7. Thermocouple damaged  
8. Control valve damaged  
7. Replace pilot assembly  
8. Replace control valve  
107105  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
TROUBLESHOOTING  
Continued  
OBSERVED PROBLEM  
POSSIBLE CAUSE  
REMEDY  
Burner does not light after ODS/pilot is lit  
1. Burner orifice is clogged  
1. Clean burner (see Cleaning and Mainte-  
nance, page 19) or replace burner orifice  
2. Contact local natural gas company  
2. Inlet gas pressure is too low  
Delayed ignition of burner  
1. Manifold pressure is too low  
2. Burner orifice is clogged  
1. Contact local natural gas company  
2. Clean burner (see Cleaning and Mainte-  
nance, page 19) or replace burner orifice  
Burner backfiring during combustion  
1. Burner orifice is clogged or damaged  
1. Clean burner (see Cleaning and Mainte-  
nance, page 19) or replace burner orifice  
2. Replace burner pressure  
2. Burner damaged  
3. Low inlet gas pressure  
3. Contact local natural gas company  
4. Gas regulator defective  
4. Replace gas regulator  
Yellow flame during burner combustion  
1. Not enough air  
1. Check burner for dirt and debris. If  
found, clean burner (see Cleaning and  
Maintenance, page 19)  
2. Gas regulator defective  
2. Replace gas regulator  
Slight smoke or odor during initial operation 1. Residues from manufacturing processes 1. Problem will stop after a few hours of  
operation  
Fireplace produces a whistling noise when 1. Turning control knob to HI position 1. Turn control knob to LO position and  
burner is lit  
when burner is cold  
let warm up for a minute  
2. Air in gas line  
2. Operate burner until air is removed from  
line. Have gas line checked by local  
natural gas company  
3. Air passageways on fireplace blocked  
3. Observe minimum installation clear-  
ances (see pages 8 through 10)  
4. Dirty or partially clogged burner orifice 4. Clean burner (see Cleaning and Mainte-  
nance, page 19) or replace burner orifice  
Whitepowderresidueformingwithinburner 1. When heated, vapors from furniture pol- 1. Turn heater off when using furniture  
box or on adjacent walls or furniture  
ish, wax, carpet cleaners, etc. may turn  
into white powder residue  
polish, wax, carpet cleaners, or similar  
products  
Continued  
107105  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
TROUBLESHOOTING  
Continued  
WARNING: If you smell gas  
Shut off gas supply.  
Do not try to light any appliance.  
Do not touch any electrical switch; do not use any phone in your  
building.  
Immediatelycallyourgassupplierfromaneighborsphone. Followthe  
gas suppliers instructions.  
If you cannot reach your gas supplier, call the fire department.  
IMPORTANT:Operatingfireplacewhereimpuritiesinairexistmaycreateodors.Cleaning  
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,  
etc., create fumes. These fumes may mix with combustion air and create odors.  
OBSERVED PROBLEM  
POSSIBLE CAUSE  
REMEDY  
Fireplace produces a clicking/ticking noise 1. Metal expanding while heating or con- 1. This is common with most fireplaces. If  
just after burner is lit or shut off  
tracting while cooling  
noise is excessive, contact qualified ser-  
vice person  
Fireplace produces unwanted odors  
1. Fireplace burning vapors from paint, hair 1. Ventilate room. Stop using odor caus-  
spray, glues, etc. (See IMPORTANT  
ing products while fireplace is running  
statement above)  
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-  
top of page  
ing Gas Connections, page 16)  
Fireplace shuts off in use (ODS operates)  
1. Not enough fresh air is available  
2. Low line pressure  
3. ODS/pilot is partially clogged  
1. Open window and/or door for ventilation  
2. Contact local natural gas company  
3. Clean ODS/pilot (see Cleaning and  
Maintenance, page 19)  
Gas odor even when control knob is in OFF 1. Gas leak. SeeWarning statement at 1. Locate and correct all leaks (see Check-  
position  
top of page  
ing Gas Connections, page 16)  
2. Control valve defective  
2. Replace control valve  
Gas odor during combustion  
1. Foreign matter between control valve 1. Take apart gas tubing and remove for-  
and burner eign matter  
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-  
top of page  
ing Gas Connections, page 16)  
Moisture/condensationnoticedonwindows 1. Not enough combustion/ventilation air  
1. Refer to Air for Combustion and Venti-  
lation requirements (page 5)  
107105  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
SPECIFICATIONS  
REPLACEMENT  
PARTS  
Btu (Variable)  
Type Gas  
14,000/26,000  
Natural Only  
Piezo  
Note: Use only original replacement parts.  
Thiswillprotectyourwarrantycoveragefor  
parts replaced under warranty.  
Ignition  
Pressure Regulator Setting  
3" W.C.  
Inlet Gas Pressure (in. of water) *  
Maximum  
PARTS UNDER WARRANTY  
10.5"  
5"  
Contact authorized dealers of this product.  
If they can’t supply original replacement  
part(s) call DESA International’s Technical  
Service Department at 1-866-672-6040 for  
referral information.  
Minimum  
Dimensions, Inches (H x W x D)  
Fireplace (including hood and screws)  
Carton  
25 7/8 x 26 13/16 x 9 3/8  
32 5/8 x 27 3/16 x 11 5/8  
Weight, pounds  
Fireplace  
When calling DESA International, have  
ready  
44 1/2 lbs.  
48 lbs.  
Shipping  
• your name  
* For purposes of input adjustment  
• your address  
• model and serial numbers of your fireplace  
• how fireplace was malfunctioning  
TECHNICAL  
SERVICE  
SERVICE HINTS  
• type of gas used (propane/LP or natural  
gas)  
When Gas Pressure Is Too Low  
• purchase date  
You may have further questions about in-  
stallation, operation, or troubleshooting. If  
so, contact DESA International’s Technical  
Service Department at 1-866-672-6040.  
• pilot will not stay lit  
• burner will have delayed ignition  
• fireplace will not produce specified heat  
Usually, we will ask you to return the part to  
the factory.  
You may feel your gas pressure is too low. When calling, please have your model and  
Ifso, contactyourlocalnaturalgassupplier. serial numbers of your heater ready.  
PARTS NOT UNDER  
WARRANTY  
You can also visit DESA International’s  
technical services web site at  
Contact authorized dealers of this product. If  
theycan’tsupplyoriginalreplacementpart(s)  
call DESA International at 1-866-672-6040  
for referral information.  
When calling DESA International, have  
ready  
• model number of your fireplace  
• the replacement part number  
107105  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
ILLUSTRATED  
PARTS  
BREAKDOWN  
3
FMH26TN  
17  
1
9
30  
8
7
4
40  
3
10  
7
40  
4
2
33  
11  
14  
25  
24  
29  
20  
23  
40  
13  
37  
14  
32  
35  
39  
34  
19  
5
38  
27  
25  
12  
6
12  
28  
18  
26  
24  
39  
36  
22  
42  
21  
15  
41  
16  
31  
107105  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions  
listed under Replacement Parts on page 23 of this manual.  
PARTS LIST  
FMH26TN  
KEY NO.  
PART NO.  
DESCRIPTION  
QTY.  
1
2
3
4
5
6
7
8
102633-02  
102624-02  
099230-02  
098304-01  
107178-01  
103209-05  
102635-02CK  
101629-02  
103209-01  
104281-02BR  
102638-01  
104285-01  
**  
099211-01  
103963-01  
102834-01  
098304-03  
098303-02  
104335-01CK  
102649-01CK  
099415-10  
102875-01  
101381-01  
099387-11  
098271-06  
107186-02  
101006-02  
098249-01  
098522-23  
102639-01  
101628-01  
102869-01  
102731-01  
103295-03BR  
107153-01  
104313-01  
104313-02  
M10908-2  
103734-01  
M11084-26  
097809-03  
101629-01  
Outer Casing Top  
Outer Casing  
Shoulder Screw  
Screw, #10 x 3/8"  
Burner  
Louvered Door  
Left and Right Side Front  
Bushing  
Top Louver  
Firebox Hood  
Firebox Top  
ODS/Pilot Assembly  
Firebox Wrapper  
Control Bracket Screw  
Inlet Tube  
1
1
14  
16  
1
1
2
1
1
1
1
1
1
2
1
1
4
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
4
2
28  
1
1
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
Burner Tube  
Screw 8-18 x 3/8"  
Regulator Screw  
Outer Shell Base  
Branch Support  
Gas Regulator  
Regulator Bracket  
Valve Cover and Piezo  
Pilot Tube  
Ignitor Cable  
Injector  
Pilot Bracket  
Nut, M5  
Gas Valve  
Baffle  
Flexible Connector  
Control Bracket  
Control Shield  
Screen Assembly  
Log Set Assembly Kit  
Right Hinge  
Left Hinge  
Hinge Screws  
Burner Support  
Hex Head Screw, #10 x 3/8"  
3/8" NPT x 3/8" Flare Brass Fitting  
Bushing  
PARTS AVAILABLE NOT SHOWN  
101054-01  
100563-01  
103470-01  
Lighting Instructions Plate  
Warning Plate  
Hardware Package  
1
1
1
** Part not available for field replacement.  
107105  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NATURAL GAS VENT-FREE FIREPLACE SYSTEM  
ACCESSORIES  
Purchase these fireplace accessories from  
your local dealer. If they cannot supply these  
accessories call DESA International’s Sales  
Department at 1-866-672-6040 for referral  
information. You can also write to the ad-  
dress listed on the back page of this manual.  
THERMOSTATICALLY -  
CONTROLLED BLOWER KIT  
GA3400T  
For all models. Provides better heat distri-  
bution. Makes fireplace more efficient.  
Automatically turns off and on as needed.  
CORNER MANTEL WITH  
FULL HEARTH BASE  
Unfinished - GMC63U  
Finished - GMC64F  
White Lacquer - GMC65W  
CLEANING KIT - GCK  
(Not Shown)  
EQUIPMENT SHUTOFF  
VALVE - GA5010  
Forusewithfireplace. Space-savingmantel  
andhearthbasecornerdesignfeaturesclean,  
classic lines. Available in a stained oak  
finish,whitelacquerfinish,oranunfinished  
birch, ready to stain or paint. Complete  
assemblyinstructionsincluded.Three-sided  
brass trim kit included.  
For all models. Your vent-free gas appli-  
ance requires regular cleaning and mainte-  
nance to prevent performance problems.  
This kit gives you the tools and instructions  
to make it easy to clean all critical areas of  
your appliance.  
For all models. Equipment shutoff valve  
with 1/8" NPT tap.  
BRASS TRIM KIT - GA6094  
Optional three-sided brass trim kit for cus-  
tom and recessed installations (when unit is  
on the floor). Provides a finished appear-  
CABINET MANTEL WITH  
FULL HEARTH BASE AND  
ance by covering rough edges of wall open- ROUNDED LEG STYLING  
ing. Included with all mantels.  
Unfinished - GMC61U  
Oak Finished - GMC60F  
(Appearance May Differ by Model)  
BRASS TRIM KIT - GA6095  
Optional four-sided brass trim kit for recessed  
built-ininstallations(whenunitisraisedoffof  
the floor. Provides a finished appearance by  
covering rough edges of wall opening.  
For use with fireplace. A mantel and hearth  
base offers compact styling and completes  
the fireplace look. Available in a oak stain  
finish, or an unfinished birch, ready to stain  
or paint. Complete assembly instructions  
included.Three-sidedbrasstrimkitincluded.  
107105  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
NOTES  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
_______________________________________________________________________________________________  
107105  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY INFORMATION  
KEEP THIS WARRANTY  
Model  
Serial No.  
Date Purchased  
Always specify model and serial numbers when communicating with the factory.  
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written  
warranty. We make no other warranty, expressed or implied.  
LIMITED WARRANTY  
VENT-FREE NATURAL GAS COMPACT HEAT MAJIC™ FIREPLACE SYSTEM  
DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years  
on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and  
maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check  
must be presented.  
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this  
fireplace to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty  
part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory  
replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a  
qualified installer in accordance with all local codes and instructions furnished with the unit.  
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become  
damagedasaresultofmisuse, accidents, lackofpropermaintenanceordefectscausedbyimproperinstallation. Travel, diagnosticcost,  
labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.  
TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT;  
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA-  
TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS  
FORAPARTICULARPURPOSETOFOUR(4)YEARSONALLCOMPONENTSANDFIVE(5)YEARSONSTAINLESSSTEEL  
BURNERS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO  
THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER  
DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.  
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or  
consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.  
For information about this warranty write:  
TM  
2701 Industrial Drive  
P.O. Box 90004  
Bowling Green, KY 42102-9004  
107105-01  
107105 01  
Rev. C  
04/02  
NOT A UPC  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki Fitness Equipment LC X50 User Manual
Evolution Technologies Oxygen Equipment OM 900M User Manual
Extron electronic Switch 2 VGAcc User Manual
Extron electronic Switch 12800 User Manual
Extron electronic Switch FOX T USW 203 User Manual
Fisher Price Baby Toy T6340 User Manual
Fisher Price Motorized Toy Car 74598 User Manual
Frigidaire Washer LTF2140FS1 User Manual
FujiFilm Digital Camera Z100fd User Manual
GE Range 10 95 CG User Manual