COMPACT HEAT MAJIC™
VENT-FREE NATURAL GAS FIREPLACE SYSTEM
OWNER’S OPERATION AND INSTALLATION MANUAL
FMH26TN
14,000 to 26,000 Btu/Hr
with Thermostat
Shown with Optional
Cabinet Mantel/Hearth
Base Accessory
WARNING: Improper installa-
WARNING: If the information in this manual
tion,adjustment,alteration,ser-
is not followed exactly, a fire or explosion
vice,ormaintenancecancause
may result causing property damage, per-
sonal injury, or loss of life.
injury or property damage. Re-
fer to this manual for correct
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
installationandoperationalpro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediatelycallyourgassupplierfrom
a neighbor’s phone. Follow the gas
supplier’s instructions.
WARNING:Thisisanunvented
gas-fired heater. It uses air
(oxygen) from the room in
whichitisinstalled.Provisions
for adequate combustion and
ventilation air must be pro-
vided.RefertoAirforCombus-
tion and Ventilation section on
page 5 of this manual.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
SAFETY
PRODUCT
FEATURES
LOCAL CODES
INFORMATION
Install and use fireplace with care. Follow all
localcodes.Intheabsenceoflocalcodes,use
the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54*.
Continued
SAFETY PILOT
14. Turn off and unplug fireplace and let
cool before servicing. Only a qualified
service person should service and re-
pair fireplace.
This fireplace has a pilot with an Oxygen
DepletionSensing(ODS)safetyshutoffsys-
tem. The ODS/pilot is a required feature for
vent-free room fireplaces. The ODS/pilot
shuts off the fireplace if there is not enough
fresh air.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
15. Operating fireplace above elevations of
4,500 feet could cause pilot outage.
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
16. Do not operate fireplace if any log is
broken. Do not operate fireplace if a
log is chipped (dime-sized or larger).
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This sys-
tem requires no matches, batteries, or other
sources to light fireplace.
Quincy, MA 02269
17. Provide adequate clearances around air
openings.
UNPACKING
1. Remove log box and fireplace from
carton. The hood is not attached.
THERMOSTATIC HEAT
CONTROL
This fireplace has a thermostat sensing bulb
and a control valve. The thermostat will
automatically modulate the heat output to
maintain a consistent room temperature.
This results in greater fireplace comfort.
This can also result in lower gas bill.
IMPORTANT: The fireplace hood is
inside the cardboard protective end
wrap on the left side of fireplace (as
viewed from front). A decal is on the
outside of the cardboard end wrap stat-
ing hood is enclosed (see Figure 2).
2. Remove hood from cardboard protec-
tive end wrap as shown in Figure 2.
3. Remove all protective packaging ap-
plied to fireplace for shipment.
PRODUCT IDENTIFICATION
Fireplace
Cabinet
4. Make sure your fireplace includes one
hardware packet.
5. Check fireplace for any shipping
damage. If fireplace is damaged,
promptly inform dealer where you
bought fireplace.
IMPORTANT:
THIS PACKAGE CONTAINS A
Hood
Screen
FIREPLACE HOOD. UNWRAP
CARTON AND REMOVE HOOD
BEFORE DISCARDING
PROTECTIVE PACKAGING.
Enclosed
Decal
Cardboard
Protective
Fireplace
End Wrap
2
Logs
1
Control Knob
Ignitor Button
Hood
Figure 1 - Vent-Free Natural Gas Fireplace System
Figure 2 - Removing Fireplace Hood
107105
3
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
Log
Screen
Shipping
Screw
ASSEMBLY
Shoulder
Screw
WARNING: Always have
branch support and screen in
place before operating fireplace.
Thispreventsexcessivetempera-
tures on fireplace surfaces.
Burner
Support
WARNING: Failure to position
thepartsinaccordancewiththese
diagrams or failure to use only
parts specifically approved with
this fireplace may result in prop-
erty damage or personal injury
ASSEMBLING FIREPLACE
Tools Required:
• Phillips screwdriver
• 5/16" hex wrench
• slotted screwdriver
Branch
Support
Screen
Installing Log
1. Lift screen up and pull out to remove.
2. Cut two plastic straps to remove the log
from the firebox cavity.
Figure 3 - Assembling Fireplace
3. An optional blower is available. See Ac-
cessories, page 26. Install optional
blower now. Follow installation in-
structions provided with blower.
4. Gently rotate hood to upright position.
Make sure hood tabs are behind lou-
vers and hood is resting on firebox top
(see Figure 4).
Assembling Hood
1. Locate four black phillips sheet metal
screws from the hardware packet.
2. Rotate hood as shown in Figure 4.
Make sure hood tabs point toward
fireplace.
4. Remove log packaging material and
discard packaging. Gently place log set
on burner support (see Figure 3). The
log should fit flat against top of burner
support and log locators fit into the slots
under the log. Do not allow log to con-
tact flame. If flame contacts log, soot
will be created.
5. Align screw holes on hood with screw
holes on firebox top.
6. Insert screws as shown in Figure 4.
Tighten screws firmly.
3. Insert hood tabs between baffle and
louvers (see Figure 4).
Louver
Hood
Hood
Tabs
Hood Tab
5. Reattach screen by placing the notches
in the screen frame over the shoulder
screws and pushing down.
Baffle
Sheet
Metal
Screw
Firebox Top
Figure 4 - Assembling Hood
107105
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Confined and Unconfined Space
PROVIDING ADEQUATE
VENTILATION
AIR FOR
The National Fuel Gas Code, ANSI Z223.1/
NFPA54definesaconfinedspaceasaspace
whose volume is less than 50 cubic feet per
1,000 Btu per hour (4.8 m3 per kw) of the
aggregate input rating of all appliances in-
stalledinthatspaceandanunconfinedspace
as a space whose volume is not less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space. Rooms
communicating directly with the space in
whichtheappliancesareinstalled*,through
openings not furnished with doors, are con-
sidered a part of the unconfined space.
COMBUSTION AND
VENTILATION
The following are excerpts from National
FuelGasCode, ANSIZ223.1/NFPA54, Sec-
tion5.3, AirforCombustionandVentilation.
WARNING: This heater shall
notbeinstalledinaconfinedspace
or unusually tight construction
unless provisions are provided
foradequatecombustionandven-
tilation air. Read the following in-
structions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will
help you classify your space and provide
adequate ventilation.
Today’s homes are built more energy effi-
cient than ever. New materials, increased
insulation, and new construction methods
helpreduceheatlossinhomes.Homeowners
weather strip and caulk around windows and
doorstokeepthecoldairoutandthewarmair
in. During heating months, home owners
want their homes as airtight as possible.
* Adjoining rooms are communicating only
iftherearedoorlesspassagewaysorventila-
tion grills between them.
Unusually Tight Construction
The air that leaks around doors and win-
dows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is de-
fined as construction where:
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper com-
bustion and ventilation.
a. walls and ceilings exposed to the
outside atmosphere have a con-
tinuous water vapor retarder with
a rating of one perm (6 x 10-11 kg
per pa-sec-m2) or less with open-
ings gasketed or sealed and
Exhaustfans, fireplaces, clothesdryers, and
fuel burning appliances draw air from the
house to operate. You must provide ad-
equate fresh air for these appliances. This
will insure proper venting of vented fuel-
burning appliances.
b. weather stripping has been
added on openable windows and
doors and
c. caulking or sealants are applied
to areas such as joints around
window and door frames, be-
tween sole plates and floors, be-
tween wall-ceiling joints, be-
tween wall panels, at penetra-
tions for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide ad-
ditional fresh air. See Ventilation Air
From Outdoors, page 7.
If your home does not meet all of the
three criteria above, proceed to De-
termining Fresh-Air Flow For Fire-
place Location, page 6.
Continued
107105
5
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height = _________________cu. ft. (volume of space)
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
_____________________(volume of space) x 20 = (Maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace
Gas water heater*
Gas furnace
Vented gas heater
Gas fireplace logs
__________________Btu/Hr
__________________Btu/Hr
__________________Btu/Hr
__________________Btu/Hr
__________________Btu/Hr
Example:
30,000
26,000
56,000
Gas water heater
Vent-free fireplace +
Btu/Hr
Btu/Hr
Btu/Hr
Total
=
Other gas appliances* + __________________Btu/Hr
Total = __________________Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ Btu/Hr (maximum the space can support)
_________________ Btu/Hr (actual amount of Btu/Hr used)
Example: 51,200 Btu/Hr (maximum the space can support)
56,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confinedspace because the actual Btu/Hr used is more than the maximum Btu/Hr the space cansupport.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
WARNING:If the area in which the heater may be operated is smaller than that defined as an unconfined space
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
themethodsdescribedintheNationalFuelGasCode,ANSIZ223.1/NFPA54,Section5.3orapplicablelocalcodes.
107105
6
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
12"
Continued
VENTILATION AIR
Ventilation Air From Inside
Building
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills
Or
Thisfreshairwouldcomefromanadjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 5). You can also
remove door into adjoining room (see op-
tion 3, Figure 5). Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
into Adjoining
Room,
Option 1
Remove
Door into
Adjoining
Room,
Option 3
12"
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
orspacesopentotheoutdoors.Thesespaces
include attics and crawl spaces. Follow the
NationalFuelGasCode,ANSIZ223.1/NFPA
54, Section 5.3, Air for Combustion and
Ventilation for required size of ventilation
grills or ducts.
Figure 5 - Ventilation Air from Inside Building Shown with Optional Mantel
Ventilated
Outlet
Attic
Air
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a
thermostat-controlledpowervent.Heatedair
enteringtheatticwillactivatethepowervent.
Outlet
Air
To Attic
To
Crawl
Space
Inlet
Air
Ventilated
Inlet Air
Crawl Space
Figure 6 - Ventilation Air from Outdoors Shown with Optional Mantel
107105
7
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
CEILING
Note: Your vent-free fireplace is designed
to be used in zero clearance installations.
Wall or framing material can be placed
directly against any exterior surface on the
rear, sides, or top of your fireplace, except
where stand-off spacers are integrally at-
tached. If standoff spacers are attached to
your fireplace, these spacers can be placed
INSTALLATION
NOTICE: This heater is intended
foruseassupplementalheat.Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
36"
Minimum
6"
Minimum
From
Sides Of
Fireplace
directly against wall or framing materials.
system’scirculatingblowerwhile
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 9).
Left
Side
Right
Side
CHECK GAS TYPE
Use only natural gas. If your gas supply is
not natural gas, do not install fireplace. Call
dealerwhereyouboughtfireplaceforproper
type fireplace.
FLOOR
0" Minimum To Top Surface Of Carpeting,
Tile Or Other Combustible Material
WARNING: A qualified ser-
vicepersonmustinstallfireplace.
Follow all local codes.
Figure7-MountingClearancesAsViewed
From Front of Fireplace Shown Built In
The Wall
INSTALLATION ITEMS
Before installing fireplace, make sure you
have the items listed below.
CEILING
WARNING: Never install the
fireplace
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• ground joint union
• sediment trap
Top Of
Mantel Can
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objectsarelessthan36inches
from the front, top, or sides of
the fireplace
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
36"
Be Flush
Minimum
With Wall
• tee joint
• pipe wrench
* ACSAdesign-certifiedequipmentshutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional CSA design-certified
equipment shutoff valve from your dealer.
See Accessories, page 26.
Right
Side
Left
Side
CAUTION: This fireplace cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Installing
fireplace next to vinyl or cloth
wall coverings or operating fire-
place where impurities (such as,
butnotlimitedto,tobaccosmoke,
aromatic candles, cleaning flu-
ids,oilorkerosenelamps,etc.)in
the air exist, may discolor walls
or cause odors.
Note:Ifdesired,purchaseafour-sidedbrass
trim kit for built-in installations. See Acces-
sories, page 26.
0" Minimum To Top Surface Of Carpeting,
Tile Or Other Combustible Material
Figure8-MountingClearancesAsViewed
From Front of Fireplace Shown with
Optional Mantel
LOCATING FIREPLACE
WARNING:Maintainthemini-
mum clearances shown in Fig-
ures 7 and 8. If you can, provide
greater clearances from floor,
ceiling, and joining wall.
Note: When installing fireplace directly on
carpeting, tile or other combustible material,
other than wood flooring, the fireplace shall
beinstalledonametalorwoodpanelextend-
ing the full width and depth of the fireplace
IMPORTANT:Vent-freefireplacesaddmois-
ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilationairmaycausemildewtoformfrom
too much moisture. See Air for Combustion
and Ventilation, pages 5 through 7.
You can recess firebox into the wall. You
can also position fireplace in the optional
cabinet or corner mantels. IMPORTANT:
Only use optional cabinet or corner mantels
specified in this manual. Purchase the op-
tional mantel from your dealer (see Acces-
sories, page 26).
CAUTION: If you install the
fireplace in a home garage
• fireplace pilot and burner must
beatleast18inchesabovefloor.
• locate fireplace where moving
vehicle will not hit it.
107105
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
9. Check all gas connections for leaks. See
INSTALLATION
WARNING: If pre-wiring, do
not connect wiring to any electri-
cal source at this time.
Checking Gas Connections, page 16.
Continued
10. If using optional brass trim kit, install
the trim after final finishing and/or
painting of wall. See instructions in-
cluded with brass trim accessory for at-
taching brass trim.
For convenience and efficiency, install
fireplace
Install fireplace electrical outlet
and connect wiring to outlet be-
fore connecting to electrical
source. The fireplace electrical
outlet is included with the
GA3450(T) blower accessory.
• where there is easy access for operation,
inspection, and service.
IMPORTANT: When finishing your fire-
box,combustiblematerialssuchaswallboard,
gypsumboard,sheetrock,drywall,plywood,
etc. maybebuttedupnexttothesidesandtop
of the firebox. Combustible materials should
never overlap the firebox front facing.
• in coldest part of room.
An optional blower kit is available from
your dealer. See Accessories, page 26. If
planningtouseblower,locatefireplacenear
an electrical outlet.
Only use the fireplace electrical
outlet supplied with the
GA3450(T) blower accessory.
BUILT-IN FIREPLACE
INSTALLATION
Note:Aqualified installer should make
all electrical connections.
WARNING: Do not allow any
combustiblematerialstooverlap
the firebox front facing.
3. Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the equipment shutoff
valve. The flexible gas line must be the
last item installed on the gas piping.
Built-ininstallationofthisfireplaceinvolves
installing fireplace into a framed-in enclo-
sure. This makes the front of fireplace flush
with wall. An optional brass trim kit acces-
sory is available (see Accessories, page 26).
Brasstrimwillextendpastsidesoffireplace
approximately 1/2 inch. This will cover the
rough edges of the wall opening. If install-
ingabuilt-inmantelabovethefireplaceyou
must follow the clearances shown in Figure
12, page 10. Follow the instructions below
to install the fireplace in this manner.
IMPORTANT: Noncombustible materials
such as brick, tile, etc. may overlap the front
facing, but should never cover any neces-
sary openings like louvered slots.
4. If you have not assembled firebox, fol-
low instructions on page 4.
WARNING: Do not allow non-
combustible materials to cover
any necessary openings like lou-
vered slots.
5. Carefully set fireplace in front of rough
opening with back of fireplace inside
wall opening.
6. Attach flexible gas line to fireplace gas
regulator. See Connecting Fireplace to
Gas Supply, page 15.
Actual Framing
WARNING: Never modify or
cover the louvered slots on the
front of the firebox.
Height
26"
26 3/4"
9 1/2"
3/4"
26 7/8"
26 7/8"
10 1/2"
3/4"
7. Bend four nailing flanges on outer cas-
ing with pliers (see Figure 11).
Front Width
Depth
8. Attach fireplace to wall studs using
nails or wood screws through holes in
nailing flange.
WARNING: Use only noncom-
bustiblemortaroradhesiveswhen
overlapping the front facing with
noncombustible facing material.
Bottom
1. Frame in rough opening. Use dimen-
sions shown in Figure 9 for the rough
opening.
If installing in a corner, use dimensions
shown in Figure 10 for the rough open-
ing. The height is 26 7/8" which is the
same as the wall opening above.
10 1
/2"
Nails or
Wood
Screws
267
/8"
3/4" Off
2. If installing GA3450(T) blower acces-
sory, do so at this time. Follow instruc-
tions included with blower accessory.
The Floor
Minimum
267
/8"
Figure9-RoughOpeningforInstallingin
Wall
Note: If not installing blower acces-
sory, you may wish to run electrical
wiring to your fireplace for future
blower installation (see Accessories,
page 26) Use only approved three-wire
electrical wiring.
365
/
8"
257
/
8
"
Nailing
Flanges
267
513
/
8
"
/
4
"
Figure 10 - Rough Opening for Installing
in Corner
Figure11-AttachingFireplacetoWallStuds
Continued
107105
9
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
3. Place mantel around fireplace/base 12. Check for leaks. See Checking Gas
INSTALLATION
assembly.
4. Assemble brass trim kit. See Assem- 13. Place mantel around fireplace. Be care-
bling Brass Trim, page 11. ful not to damage wall or mantel.
5. Firmly snap brass trim kit on shoulder 14. Place brass trim kit on the shoulder
Connections, page 16.
Continued
Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace,
youmustmeetminimumclearancebetween
mantel shelf and top of fireplace opening.
screws. Shoulder screws are located on
fireplace cabinet (see Figure 13).
screws located on the side and top of
the fireplace. Firmly snap the brass trim
over the shoulder screws on fireplace
(see Figure 13).
6. Align brass trim kit for flush fit around
opening.
NOTICE:Surfacetemperaturesof
adjacent walls and mantels be-
comehotduringoperation.Walls
and mantels above the firebox
may become hot to the touch. If
installedproperly,thesetempera-
turesmeettherequirementofthe
national product standard. Fol-
low all minimum clearances
shown in this manual.
15. Adjust assembly to remove any gaps.
Attach remaining two 3" wood screws
from hardware pack through openings
inside of fireplace sides into the man-
tel. The openings are located at top be-
hind the area for the black louvers (see
Figure 13).
7. Use two 3" wood screws provided and
attach fireplace base to wooden base
(see Figure 13).
8. Remove brass trim kit and mantel. Be
careful not to damage wall or mantel.
9. Place wood base next to wall at instal-
lation location.
16. Reinstall top black louvers.
10. Attach wood base to floor with two 1 3/4"
black screws provided (see Figure 14).
If the floor is concrete use anchor method
(see AttachingWood Base to Solid Floor,
page 14).
Hole for 3"
wood screw
Shoulder
Screws
for attaching
fireplace to
mantel
NOTICE: If your installation does
notmeettheminimumclearances
shown, you must do one of the
following:
11. Install gas line. See Connecting To Gas
Supply, page 14.
Mantel Shelf
• raise the mantel to an accept-
able height
• remove the mantel
10"
Note:
All vertical
8"
measurements
are from top of
fireplace
6"
2 1/2
OPTIONAL MANTEL
INSTALLATION
"
opening to
Note: Refer to instructions provided with
the mantel for assembly instructions. Refer
to instructions below for system installa-
tion. Refer to instructions on page 4 for
firebox assembly. Blower accessory should
be installed if it is being used (see Accesso-
ries, page 26).
bottom of
Hole for 3"
mantel shelf. All
measurements
are in inches.
wood screw
for attaching
fireplace to
wooden base
Assembled
Brass Trim
Side of
Firebox
Figure 13 - Attaching Brass Trim to
Fireplace
1. Unscrew four brass screws that attach
top louver to fireplace. Remove louver
from fireplace and set aside.
1 3/4" Screw
2. Place fireplace on wood base.
Wood Base
Figure 12 - Minimum Mantel Clearances
for Built-In Installation
Figure 14 - Attaching Wood Base to Floor
107105
10
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Branch
Support
INSTALLING BLOWER
ACCESSORY GA3450T
INSTALLATION
Shoulder
Screw
Continued
Removing Upper Louver
Assembly
Assembling Brass Trim (Brass
trim shipped with mantel)
Remove
Screw
1. Remove packaging from three remain-
ing pieces of brass trim.
To install the blower accessory, you must
first remove the upper louver assembly.
Valve
Cover
Shield
2. Locate two adjusting plates with set 1. Lift screen off heater.
screws, and two shims in the hardware
2. Remove 4 screws from louver assem-
2
packet.
bly (see Figure 16). Save these screws.
3. Align shim under adjusting plate as
shown in Figure 15.
3. Pull louver assembly straight out from
the cabinet. Be careful not to scratch
the paint. Set louver assembly and
4. Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 15).
screws aside.
1
Blower Bracket
Mounting Holes
5. Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 15).
Bottom Louver
Assembly
Snap
Bushings
6. While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.
Figure 17 - Removing Valve Cover Shield
Installing Blower Assembly
7. Repeat steps 1 through 6 for other corner.
Upper Louver
Assembly
CAUTION: Label all wires
priortodisconnectionwhenser-
vicing controls. Wiring errors
can cause improper and danger-
ous operation.
8. Set brass assembly aside for later in-
stallation.
Brass Screws
Top Brass
Figure 16 - Removing Upper Louver
Assembly
Trim
Set
Screws
Slot
Removing Valve Cover Shield
CAUTION: Verify proper op-
eration after servicing.
1. Open bottom louver assembly by
swinging the assembly down (see Fig-
ure 17).
Mitered
Edge
Note: If you are using a mantel with your
heater, use the following instructions. If
your heater is built-in, see For Built-In In-
stallation on page 13.
Shim
2. Using short Phillips screwdriver, re-
move the screw under the center of the
branch support. Rotate valve cover
shield clockwise and slide out.
IMPORTANT: Do not remove shoul-
der screw on the left side of valve cover
shield. Slide the valve cover shield off
of the shoulder screw (see Figure 17).
Side Brass
Trim
Adjusting
Plate
1. Install snap bushings found in hardware
kit into both holes in rear of valve cover
shield.
Slot
2. Make sure the wire harness is firmly
connected to the terminals on the blower
bracket assembly.
Note: If you do not have a short
Phillips screwdriver, the screen, twigs,
and branch support must be removed
so a longer screwdriver may be used.
See Connecting Fireplace To Gas Sup-
ply, page 15 and follow step 2.
Figure 15 - Assembling Brass Trim
3. Note the wire locations on back of
AUTO/OFF/ON switch. The terminals
on back of switch are numbered 1, 2,
and 3. Carefully remove red wire from
terminal 1 and blue wire from terminal
3. Black wire can remain on middle
terminal 2 (see Figure 18, page 12).
Continued
107105
11
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
6. Route the wire harness through the 9. Install the switch plate on the valve
INSTALLATION
hole in left side of baffle. Pull wire
harness through lower opening above
where the valve shield was removed.
(see Figure 18).
cover shield with 2 #10 screws provided
(see Figure 19). Reinstall the valve
cover shield. Route power cord out of
the cabinet by inserting it through the
bushing on the outer casing (see Fig-
ure 18). Plug fan kit into 120-Volt
grounded power supply and test opera-
tion. Note: When switch is in the
AUTO position, the fan will start after
the heater has run for a few moments.
The fan will continue to run for sev-
eral moments after the heater has been
turned off. When switch is in the ON
position, the fan will run until turned
to OFF. Reinstall upper louver assem-
bly and hood if previously removed,
(see Figure 16, page 11). Close lower
louver door.
Continued
4. Carefully disconnect green and white
wires at their insulated connectors.
7. Insert the 4 wire harness into one of the
round holes in the rear of the valve cover
shield and through the rectangular hole
in the front of shield (see Figure 18).
5. In top of the heater cabinet, locate the
four mounting holes on the outer cas-
ing. Align these four holes with those
on the blower bracket assembly. Attach
blower bracket assembly to the outer
casing with 4 #10 screws provided (see
Figure 18).
8. Reconnect red wire to switch position
3. Reconnect blue wire to switch posi-
tion 1. Reconnect green and white wires.
Wiring Routing
Hole in Baffle
Blower Bracket
Assembly
Screw
Baffle
Valve Cover
Shield
Wire
Harness
Switch
Switch
Plate
Power
Cord
Screw
3
2
1
Figure19-InstallingSwitchPlatetoValve
Cover Shield
Red
Blue
Switch
Plate
Wire
Harness
Valve Cover
Shield
Box Cover
Figure 18 - Installing Blower Bracket Assembly
107105
12
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Fan Switch
INSTALLATION
(Auto/Off/On)
Auto
1
Continued
2
Off
3
Thermostat
Switch
(N.O.)
Blue
For Built-In Installation
On
WARNING: A licensed elec-
trician must connect the wiring
harness to electrical supply fol-
lowing all local codes. Electri-
cian must provide a clamp on
the box cover to secure the wir-
ing. Wiring should be routed
through the bushing in the hole
on the outer casing of heater.
Blue
110/115
V.A.C.
Red
Blower
Motor
Black
Red
White
Green
White
Green
Figure 20 - Wiring Diagram For Blower Accessory Built-In Installation
Follow instructions Removing Valve Cover
Shield (page 11), then
Blower Bracket
Assembly
1. Install a snap bushing found in hardware
kit into one of the holes found on rear of
valve cover shield. The other hole is for
a strain relief clamp (not supplied) to
secure incoming electrical supply.
Screw
2. Follow steps 2 through 6 in Installing
Blower Assembly, pages 11 and 12.
Also remove black wire from middle
switch terminal 2.
3. Remove black plastic strain relief and
power cord from switch plate. The
power cord supplied will not be used in
built-in installations. Pop in the plastic
snap bushing found in hardware kit into
the hole left by supply cord/strain relief.
Switch
Wire
Harness
Power
Cord
Outlet
Receptacle
3
2
1
4. A licensed electrician must follow the
wiring diagram to connect incoming
electrical supply to fan kit wiring har-
ness (see Figure 20).
Red
Blue
5. Plug power cord to the outlet receptacle
(not provided) as shown in Figure 21.
Wind the extra cable in power cord and
and tie it up with the plastic wire strap
(see Figure 21). Set the cable bundle
between the burner bracket and outer
casing, away from the burner.
Switch Plate
Plastic Wire
Strap
Valve
Cover
Shield
6. Reinstall valve cover shield.
Box Cover
Wire
7. Test to make sure the blower is work-
ing properly.
Harness
Clamp Connector
(not included)
8. Reinstall upper louver assembly and
hood if previously removed, (see Figure
16, page 11). Close lower louver door.
Figure 21 - Installing Blower Bracket Assembly
Continued
107105
13
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
CONNECTING TO GAS
INSTALLATION
CAUTION:Use only new,
SUPPLY
Continued
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" or greater diameter to al-
low proper gas volume to fire-
place. If pipe is toovolumepres-
sure will occur.
WARNING: This appliance re-
quires a 45° male flare fitting 5/8"-
18 UNF (Unified National Fine
Thread) inlet connection and the
flexible gas line provided.
Extension Cord
Use extension cord if needed. The cord must
have a three-prong, grounding plug and a
three-hole receptacle. Make sure cord is in
good shape. It must be heavy enough to carry
the current needed. An undersized cord will
cause a drop in line voltage. This will result
in loss of power and overheating. Use a No.
16 AWG cord for lengths less than 50 feet.
WARNING: A qualified ser-
vice person must connect fire-
place to gas supply. Follow all
local codes.
Installation must include an equipment
shutoff valve, union, and plugged 1/8" NPT
tap. Locate NPT tap within reach for test
gauge hook up. NPT tap must be upstream
from fireplace (see Figure 23).
Attaching Wood Base to Solid
Floor
IMPORTANT: Install main gas valve
(equipment shutoff valve) in an accessible
location. The main gas valve is for turning
on or shutting off the gas to the appliance.
WARNING: Never connect
fireplace to private (non-utility)
gas wells. This gas is commonly
known as wellhead gas.
For attaching base to solid floors (concrete
or masonry)
Note: Floor anchors and mounting screws
are in hardware package. The hardware
package is provided with fireplace.
Check your building codes for any special
requirementsforlocatingequipmentshutoff
valve to fireplaces.
IMPORTANT: Check gas line pressure be-
fore connecting fireplace to gas line. Gas
line pressure must be no greater than 14
1. Drill holes at marked locations using
5/16" drill bit. For solid floors (con- inchesofwater.Ifgaslinepressureishigher,
crete or masonry), drill at least 1" deep. fireplace regulator damage could occur.
ApplypipejointsealantlightlytomaleNPT
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
2. Fold floor anchor as shown in Figure 22.
CSA Design-Certified
3. Insert floor anchor (wings first) into
hole. Tap anchor flush to floor.
Equipment Shutoff Valve
With 1/8" NPT Tap*
CAUTION:Usepipejointseal-
ant that is resistant to liquid pe-
troleum (LP) gas.
4. Insert mounting screws through base
and into floor anchors.
5. Tighten screws until base is firmly fas-
tened to floor.
We recommend that you install a sediment
trap in supply line as shown in Figure 23.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
betweenfuelsupplyandheater.Locatesedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into fireplace controls. If sediment
trap is not installed or is installed wrong,
fireplace may not run properly.
From Gas
Meter (5"
W.C. to
10.5" W.C.
Pressure)
3" Minimum
Cap Pipe Tee
Figure 22 - Folding Anchor
Nipple Joint
Sediment Trap
Figure 23 - Gas Connection
* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 26.
107105
14
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
5. Check all gas connections for leaks. See
INSTALLATION
CAUTION: Avoid damage to
Checking Gas Connections, page 16.
Continued
regulator.Holdgasregulatorwith
wrenchwhenconnectingittogas
piping and/or fittings.
6. Replace branch support back into fire-
place. Feed flexible gas line into fire-
place base area while replacing branch
support. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach branch support to fireplace with
screws removed in step 2.
CONNECTING EQUIPMENT
SHUTOFF VALVE TO
HEATER CONTROL
4. Apply pipe joint sealant lightly to male
threads of gas connector attached to
flexible gas line/equipment shutoff
valve (see Figure 25).
Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
Screen
Shipping
Screw
1. Remove fireplace screen. Remove two
screws that hold fireplace screen in
place for shipping. These screws are
located near top of screen. Discard
screws. Lift fireplace screen up and pull
out to remove.
Branch
Support
Shoulder
Screw
2. Remove screws that attach branch sup-
port to fireplace (see Figure 24). Care-
fully lift up branch support and remove
from fireplace (see Figure 24).
Flexible
Gas Line
3. Route flexible gas line, included, from
fireplace control to equipment shutoff
valve through side or rear access holes
in outer casing.
NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
fromthefireplace(seeFigure25).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.
Screen
Figure 24 - Removing Branch Support From Fireplace
To Fireplace
Gas Regulator
Equipment Shutoff Valve
Provided by Installer
Flexible Gas Line from
Fireplace Gas Regulator
To External
Regulator
Figure 25 - Attaching Flexible Gas Line to Equipment Shutoff Valve
Continued
107105
15
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
Pressure Testing Fireplace Gas
Connections
1. Open equipment shutoff valve (see Fig-
INSTALLATION
Continued
1. Close equipment shutoff valve (see Fig-
ure 26).
ure 26).
CHECKING GAS
CONNECTIONS
2. Pressurize supply piping system by either
2. Open main gas valve located on or near
gas meter.
using compressed air or opening main gas
valve located on or near gas meter.
3. Make sure control knob of fireplace is
in the OFF position.
WARNING: Test all gas pip-
3. Check all joints from gas meter to equip-
ment shutoff valve (see Figure 27).Apply
a noncorrosive leak detection fluid to gas
joints. Bubbles forming show a leak.
ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.
4. Check all joints from equipment shutoff
valve to thermostat gas valve (see Fig-
ure 27). Apply a noncorrosive leak de-
tection fluid to gas joints. Bubbles
forming show a leak.
4. Correct all leaks at once.
WARNING:Neveruseanopen
flame to check for a leak. Apply a
noncorrosiveleakdetectionfluid
toalljoints.Bubblesformingshow
a leak. Correct all leaks at once.
5. Correct all leaks at once.
Open
Equipment
Shutoff
Valve
6. Light fireplace (see Operating Fire-
place, pages 17 and 18). Check all other
internal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas
to Appliance, page 18).
Pressure Testing Gas Supply
Piping System
O
Closed
8. Replace front panel.
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
Figure 26 - Equipment Shutoff Valve
1. Disconnect appliance with its appliance
main gas valve (control valve) and equip-
ment shutoff valve from gas supply pip-
ing system. Pressures in excess of 1/2
psig will damage fireplace regulator.
Equipment
Shutoff
Valve
2. Cap off open end of gas pipe where
equipment shutoff valve was connected.
Gas Meter
3. Pressurize supply piping system by either
using compressed air or opening main gas
valve located on or near gas meter.
4. Check all joints of gas supply piping
system. Apply a noncorrosive leak de-
tection fluid to gas joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment
shutoff valve to gas supply. Check re-
connected fittings for leaks.
Figure 27 - Checking Gas Joints
107105
16
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Note: You may be running this fire-
place for the first time after hooking
up to gas supply. If so, the control
knob may need to be pressed in for
30 seconds or more. This will allow
air to bleed from the gas system.
• If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
LIGHTING
INSTRUCTIONS
OPERATING
FIREPLACE
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not fol-
low these instructions exactly, a
fireorexplosionmayresultcaus-
ing property damage, personal
injury or loss of life.
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also be
present. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.
6. With control knob pressed in, push
down and release ignitor button.
This will light pilot. The pilot is at-
tached to the front of burner. If
needed, keep pressing ignitor but-
ton until pilot lights.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
Note: If pilot does not stay lit, refer
to Troubleshooting, pages 20 through
22. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure, page 18.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
1. STOP! Read the safety information,
column 1.
2. Make sure equipment shutoff valve
is fully open.
3. Turn control knob clockwise
to the OFF position.
WHAT TO DO IF YOU SMELL
GAS
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
4. Wait five (5) minutes to clear out any
gas.Then smell for gas, including near
the floor. If you smell gas, STOP! Fol-
low “B” in the safety information,
column 1. If you don’t smell gas, go
to the next step.
Note: If pilot goes out, repeat steps
3 through 7. This fireplace has a
safety interlock system. Wait one (1)
minute before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The
main burner should light. Set control
knob to any heat level between HI
and LO.
5. Turn control knob counterclockwise
the PILOT position. Press
in control knob for five (5) seconds
(see Figure 28).
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.
Control Knob
Ignitor Button
CAUTION:Donottrytoadjust
heatinglevelsbyusingtheequip-
ment shutoff valve.
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas con-
trol which has been under water.
Thermocouple
Ignitor Electrode
Pilot Burner
Figure 28 - Control Knob In The OFF
Position
Figure 29 - Pilot
Continued
107105
17
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Light-
OPERATING
INSPECTING
BURNER
FIREPLACE
Continued
ing Instructions, page 17.
Check pilot flame pattern and burner flame
pattern often.
2. With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
to the OFF position.
PILOT FLAME PATTERN
Figure31showsacorrectpilotflamepattern.
Figure 32 shows an incorrect pilot flame
pattern. Theincorrectpilotflameisnotprop-
erlyheatingthethermocouple.Thiswillcause
the thermocouple to cool. When the thermo-
couple cools, the fireplace will shut down.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, page 17.
2. Turn off all electric power to the ap-
pliance if service is to be performed.
Shutting Off Burner Only (pilot
stays lit)
OPERATING BLOWER
If pilot flame pattern is incorrect, as shown
in Figure 32
This blower has three settings: ON, OFF,
andAUTO.IntheONposition,theblower
will operate constantly. In the OFF posi-
tion, the blower will not operate. In the
AUTOposition,theblowerwillstartwhen
thethermostatsensesasufficientincrease
in firebox temperature.
Turn control knob clockwise
the PILOT position.
to
• turn fireplace off (see To Turn Off Gas to
Appliance)
THERMOSTAT
CONTROL OPERATION
• see Troubleshooting, pages 20 through 22
Note: The pilot flame on natural gas units
will have a slight curve, but flame should be
blue and have no yellow or orange color.
The thermostatic control used on this fire-
place differs from standard thermostats.
Standard thermostats simply turn on and
off the burner. The thermostat used on
this fireplace senses the room tempera-
ture. The thermostat adjusts the amount
of gas flow to the burner. This increases or
decreasestheburnerflameheight.Attimes
the room may exceed the set temperature.
If so, the burner will shut off. The burner
willcyclebackonwhenroomtemperature
drops below the set temperature.
Note: Your fireplace and thermostat
blower will not turn on and off at the
same time. The fireplace may run for
several minutes before the blower turns
on.Aftertheheatermodulatestothepilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.
Thermocouple
Pilot Burner
Note: It is safe to operate fireplace with
blower turned off. However, the blower
helps distribute heated air from the
fireplace.
The control knob can be set to any heat
level between HI and LO.
Figure 31 - Correct Pilot Flame Pattern
Auto/Off/On Switch
Note: The thermostat sensing bulb mea-
sures the temperature of air near the
fireplace cabinet. This may not always
agree with room temperature (depend-
ing on housing construction, installation
location, room size, open air tempera-
tures, etc.). Frequent use of your fire-
place will let you determine your own
comfort levels.
Thermocouple
Pilot Burner
O
N
OFF
Figure 32 - Incorrect Pilot Flame Pattern
Figure 30 - Auto/Off/On Switch
107105
18
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
4. Check the injector holder located at the
INSPECTING
CLEANING AND
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hair with a soft cloth or vacuum
cleaner nozzle.
BURNER
MAINTENANCE
Continued
WARNING: Turn off fireplace
and let cool before cleaning.
BURNER FLAME PATTERN
5. Blow air into the primary air holes on
the injector holder.
Figure 33 shows a correct burner flame
pattern.Figure34showsanincorrectburner
flame pattern. The incorrect burner flame
pattern shows sporadic, irregular flame tip-
ping. The flame should not be dark or have
an orange/reddish tinge.
6. In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.
CAUTION:Youmustkeepcon-
trol areas, burner, and circulating
air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fiedserviceperson.Fireplacemay
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, bedding material, etc.
Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 36). With the unit off, lightly
blow air through the air inlet hole. You may
blowthroughadrinkingstrawifcompressed
air is not available.
Note: When using the fireplace the first
time, the flame will be orange for approxi-
mately one hour until the log cures.
Ifburnerflamepatternisincorrect,asshown
in Figure 34
• turn fireplace off (see To Turn Off Gas to
Appliance, page 18)
CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE
Injector Holder
• see Troubleshooting, pages 20 through 22
The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
videsacleanburningflame. Keeptheseholes
clear of dust, dirt, lint, and pet hair. Clean
these air inlet holes prior to each heating
season.Blockedairholeswillcreatesoot.We
recommendthatyoucleantheuniteverythree
months during operation and have heater in-
spected yearly by a qualified service person.
Ports/Slots
Burner
Tube
Figure 33 - Correct Burner Flame Pattern
Primary Air Inlet
Holes
Figure 35 - Injector Holder On Outlet
Burner Tube
Wealsorecommendthatyoukeeptheburner
tube and pilot assembly clean and free of
dustanddirt.Tocleanthesepartswerecom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tionsonthe can, youcoulddamage the pilot
assembly.
Pilot Air
Inlet Hole
Figure34-IncorrectBurnerFlamePattern
Figure 36 - Pilot Inlet Air Hole
1. Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
CABINET
Air Passageways
2. Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 35).
• Use a vacuum cleaner or pressurized air
to clean.
Exterior
3. Blow air through the ports/slots and
holes in the burner.
• Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
107105
19
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
TROUBLESHOOTING
Note: For additional help, visit DESA
International’stechnicalservicewebsite
WARNING: Turn off and un-
plug fireplace and let cool before
servicing. Only a qualified ser-
vice person should service and
repair fireplace.
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot.ThiscandamageODS/
pilot unit.
Note:Alltroubleshootingitemsarelistedin
order of operation.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no 1. Ignitor cable pinched or wet
spark at ODS/pilot
1. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
2. Ignitor electrode not connected to igni- 2. Reconnect ignitor cable
tor cable
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned wrong
3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace pilot assembly
6. Replace pilot assembly
When ignitor button is pressed, there is 1. Gas supply turned off or equipment 1. Turn on gas supply or open equipment
spark at ODS/pilot but no ignition
shutoff valve closed
shutoff valve
2. Control knob not in PILOT position
2. Turn control knob to PILOT position
3. Control knob not pressed in while in 3. Press in control knob while in PILOT
PILOT position
position
4. Air in gas lines when installed
4. Continue holding down control knob. Re-
peat igniting operation until air is removed
5. Clean ODS/pilot (see Cleaning and
Maintenance, page 19) or replace ODS/
pilot assembly
5. ODS/pilot is clogged
6. Gas regulator setting is not correct
6. Replace gas regulator
ODS/pilot lights but flame goes out when 1. Control knob not fully pressed in
1. Press in control knob fully
control knob is released
2. Control knob not pressed in long enough 2. After ODS/pilot lights, keep control
knob pressed in 30 seconds
3. Safety interlock system has been triggered 3. Wait one minute for safety interlock sys-
tem to reset. Repeat ignition operation
4. Equipment shutoff valve not fully open 4. Fully open equipment shutoff valve
5. Thermocouple connection loose at con- 5. Hand tighten until snug, then tighten 1/4
trol valve
turn more
6. Pilot flame not touching thermocouple, 6. A) Contact local natural gas company
which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
B) Clean ODS/pilot (see Cleaning and
Maintenance, page 19) or replace ODS/
pilot assembly
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
7. Thermocouple damaged
8. Control valve damaged
7. Replace pilot assembly
8. Replace control valve
107105
20
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
1. Burner orifice is clogged
1. Clean burner (see Cleaning and Mainte-
nance, page 19) or replace burner orifice
2. Contact local natural gas company
2. Inlet gas pressure is too low
Delayed ignition of burner
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Contact local natural gas company
2. Clean burner (see Cleaning and Mainte-
nance, page 19) or replace burner orifice
Burner backfiring during combustion
1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Mainte-
nance, page 19) or replace burner orifice
2. Replace burner pressure
2. Burner damaged
3. Low inlet gas pressure
3. Contact local natural gas company
4. Gas regulator defective
4. Replace gas regulator
Yellow flame during burner combustion
1. Not enough air
1. Check burner for dirt and debris. If
found, clean burner (see Cleaning and
Maintenance, page 19)
2. Gas regulator defective
2. Replace gas regulator
Slight smoke or odor during initial operation 1. Residues from manufacturing processes 1. Problem will stop after a few hours of
operation
Fireplace produces a whistling noise when 1. Turning control knob to HI position 1. Turn control knob to LO position and
burner is lit
when burner is cold
let warm up for a minute
2. Air in gas line
2. Operate burner until air is removed from
line. Have gas line checked by local
natural gas company
3. Air passageways on fireplace blocked
3. Observe minimum installation clear-
ances (see pages 8 through 10)
4. Dirty or partially clogged burner orifice 4. Clean burner (see Cleaning and Mainte-
nance, page 19) or replace burner orifice
Whitepowderresidueformingwithinburner 1. When heated, vapors from furniture pol- 1. Turn heater off when using furniture
box or on adjacent walls or furniture
ish, wax, carpet cleaners, etc. may turn
into white powder residue
polish, wax, carpet cleaners, or similar
products
Continued
107105
21
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediatelycallyourgassupplierfromaneighbor’sphone. Followthe
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT:Operatingfireplacewhereimpuritiesinairexistmaycreateodors.Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Fireplace produces a clicking/ticking noise 1. Metal expanding while heating or con- 1. This is common with most fireplaces. If
just after burner is lit or shut off
tracting while cooling
noise is excessive, contact qualified ser-
vice person
Fireplace produces unwanted odors
1. Fireplace burning vapors from paint, hair 1. Ventilate room. Stop using odor caus-
spray, glues, etc. (See IMPORTANT
ing products while fireplace is running
statement above)
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-
top of page
ing Gas Connections, page 16)
Fireplace shuts off in use (ODS operates)
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Open window and/or door for ventilation
2. Contact local natural gas company
3. Clean ODS/pilot (see Cleaning and
Maintenance, page 19)
Gas odor even when control knob is in OFF 1. Gas leak. SeeWarning statement at 1. Locate and correct all leaks (see Check-
position
top of page
ing Gas Connections, page 16)
2. Control valve defective
2. Replace control valve
Gas odor during combustion
1. Foreign matter between control valve 1. Take apart gas tubing and remove for-
and burner eign matter
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-
top of page
ing Gas Connections, page 16)
Moisture/condensationnoticedonwindows 1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Venti-
lation requirements (page 5)
107105
22
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
SPECIFICATIONS
REPLACEMENT
PARTS
Btu (Variable)
Type Gas
14,000/26,000
Natural Only
Piezo
Note: Use only original replacement parts.
Thiswillprotectyourwarrantycoveragefor
parts replaced under warranty.
Ignition
Pressure Regulator Setting
3" W.C.
Inlet Gas Pressure (in. of water) *
Maximum
PARTS UNDER WARRANTY
10.5"
5"
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Technical
Service Department at 1-866-672-6040 for
referral information.
Minimum
Dimensions, Inches (H x W x D)
Fireplace (including hood and screws)
Carton
25 7/8 x 26 13/16 x 9 3/8
32 5/8 x 27 3/16 x 11 5/8
Weight, pounds
Fireplace
When calling DESA International, have
ready
44 1/2 lbs.
48 lbs.
Shipping
• your name
* For purposes of input adjustment
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
TECHNICAL
SERVICE
SERVICE HINTS
• type of gas used (propane/LP or natural
gas)
When Gas Pressure Is Too Low
• purchase date
You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-866-672-6040.
• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
Usually, we will ask you to return the part to
the factory.
You may feel your gas pressure is too low. When calling, please have your model and
Ifso, contactyourlocalnaturalgassupplier. serial numbers of your heater ready.
PARTS NOT UNDER
WARRANTY
You can also visit DESA International’s
technical services web site at
Contact authorized dealers of this product. If
theycan’tsupplyoriginalreplacementpart(s)
call DESA International at 1-866-672-6040
for referral information.
When calling DESA International, have
ready
• model number of your fireplace
• the replacement part number
107105
23
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
ILLUSTRATED
PARTS
BREAKDOWN
3
FMH26TN
17
1
9
30
8
7
4
40
3
10
7
40
4
2
33
11
14
25
24
29
20
23
40
13
37
14
32
35
39
34
19
5
38
27
25
12
6
12
28
18
26
24
39
36
22
42
21
15
41
16
31
107105
24
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions
listed under Replacement Parts on page 23 of this manual.
PARTS LIST
FMH26TN
KEY NO.
PART NO.
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
102633-02
102624-02
099230-02
098304-01
107178-01
103209-05
102635-02CK
101629-02
103209-01
104281-02BR
102638-01
104285-01
**
099211-01
103963-01
102834-01
098304-03
098303-02
104335-01CK
102649-01CK
099415-10
102875-01
101381-01
099387-11
098271-06
107186-02
101006-02
098249-01
098522-23
102639-01
101628-01
102869-01
102731-01
103295-03BR
107153-01
104313-01
104313-02
M10908-2
103734-01
M11084-26
097809-03
101629-01
Outer Casing Top
Outer Casing
Shoulder Screw
Screw, #10 x 3/8"
Burner
Louvered Door
Left and Right Side Front
Bushing
Top Louver
Firebox Hood
Firebox Top
ODS/Pilot Assembly
Firebox Wrapper
Control Bracket Screw
Inlet Tube
1
1
14
16
1
1
2
1
1
1
1
1
1
2
1
1
4
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
4
2
28
1
1
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
Burner Tube
Screw 8-18 x 3/8"
Regulator Screw
Outer Shell Base
Branch Support
Gas Regulator
Regulator Bracket
Valve Cover and Piezo
Pilot Tube
Ignitor Cable
Injector
Pilot Bracket
Nut, M5
Gas Valve
Baffle
Flexible Connector
Control Bracket
Control Shield
Screen Assembly
Log Set Assembly Kit
Right Hinge
Left Hinge
Hinge Screws
Burner Support
Hex Head Screw, #10 x 3/8"
3/8" NPT x 3/8" Flare Brass Fitting
Bushing
PARTS AVAILABLE — NOT SHOWN
101054-01
100563-01
103470-01
Lighting Instructions Plate
Warning Plate
Hardware Package
1
1
1
** Part not available for field replacement.
107105
25
Download from Www.Somanuals.com. All Manuals Search And Download.
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
ACCESSORIES
Purchase these fireplace accessories from
your local dealer. If they cannot supply these
accessories call DESA International’s Sales
Department at 1-866-672-6040 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.
THERMOSTATICALLY -
CONTROLLED BLOWER KIT
GA3400T
For all models. Provides better heat distri-
bution. Makes fireplace more efficient.
Automatically turns off and on as needed.
CORNER MANTEL WITH
FULL HEARTH BASE
Unfinished - GMC63U
Finished - GMC64F
White Lacquer - GMC65W
CLEANING KIT - GCK
(Not Shown)
EQUIPMENT SHUTOFF
VALVE - GA5010
Forusewithfireplace. Space-savingmantel
andhearthbasecornerdesignfeaturesclean,
classic lines. Available in a stained oak
finish,whitelacquerfinish,oranunfinished
birch, ready to stain or paint. Complete
assemblyinstructionsincluded.Three-sided
brass trim kit included.
For all models. Your vent-free gas appli-
ance requires regular cleaning and mainte-
nance to prevent performance problems.
This kit gives you the tools and instructions
to make it easy to clean all critical areas of
your appliance.
For all models. Equipment shutoff valve
with 1/8" NPT tap.
BRASS TRIM KIT - GA6094
Optional three-sided brass trim kit for cus-
tom and recessed installations (when unit is
on the floor). Provides a finished appear-
CABINET MANTEL WITH
FULL HEARTH BASE AND
ance by covering rough edges of wall open- ROUNDED LEG STYLING
ing. Included with all mantels.
Unfinished - GMC61U
Oak Finished - GMC60F
(Appearance May Differ by Model)
BRASS TRIM KIT - GA6095
Optional four-sided brass trim kit for recessed
built-ininstallations(whenunitisraisedoffof
the floor. Provides a finished appearance by
covering rough edges of wall opening.
For use with fireplace. A mantel and hearth
base offers compact styling and completes
the fireplace look. Available in a oak stain
finish, or an unfinished birch, ready to stain
or paint. Complete assembly instructions
included.Three-sidedbrasstrimkitincluded.
107105
26
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
NOTES
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
107105
27
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE NATURAL GAS COMPACT HEAT MAJIC™ FIREPLACE SYSTEM
DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years
on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and
maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check
must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this
fireplace to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty
part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory
replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a
qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become
damagedasaresultofmisuse, accidents, lackofpropermaintenanceordefectscausedbyimproperinstallation. Travel, diagnosticcost,
labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.
TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT;
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA-
TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS
FORAPARTICULARPURPOSETOFOUR(4)YEARSONALLCOMPONENTSANDFIVE(5)YEARSONSTAINLESSSTEEL
BURNERS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO
THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER
DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or
consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
TM
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
107105-01
107105 01
Rev. C
04/02
NOT A UPC