Model EP724H
ONE (1) YEAR LIMITED WARRANTY
EURO-PRO Operating LLC warrants this product to be free from defects in material
and workmanship for a period of one (1) year from the date of the original purchase.
This warranty applies only to normal domestic household use.
Should your appliance fail to operate properly while in use under normal household
conditions within the one (1) year warranty period, return the complete appliance and
accessories, freight prepaid to EURO-PRO Operating LLC at the address given below.
If the appliance is found to be defective in material or workmanship, EURO-PRO
Operating LLC will repair or replace it free of charge. Proof of purchase date and
$19.95 to cover the cost of return shipping and handling must be included.* Return to:
Bagless Cyclonic Canister
OWNER’S MANUAL
EURO-PRO Operating LLC, 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901
Model EP724H
120V., 60Hz., 10.3 Amps
Non-durable parts including, without limitation, rotating brushes and electrical parts
which normally require replacement are specifically excluded from warranty.
The liability of EURO-PRO Operating LLC is limited solely to the cost of the repair or
replacement of the unit at our option. This warranty does not cover normal wear of parts
and does not apply to any unit that has been tampered with or used for commercial
purposes. This limited warranty does not cover damage caused by misuse, abuse,
negligent handling or damage due to faulty packaging or mishandling in transit. This
warranty does not cover damage or defects caused by or resulting from damages from
shipping or repairs, service or alterations to the product or any of its parts, which have
been performed by a repair person not authorized by EURO-PRO Operating LLC.
This warranty is extended to the original purchaser of the unit and excludes all other
legal and/or conventional warranties. The responsibility of EURO-PRO Operating LLC
if any, is limited to the specific obligations expressly assumed by it under the terms of
the limited warranty. In no event is EURO-PRO Operating LLC liable for incidental or
consequential damages of any nature whatsoever. Some states do not permit the
exclusion or limitation of incidental or consequential damages, so the above may not
apply to you.
This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.
*Important: Carefully pack item to avoid damage in shipping. Be sure to include
proof of purchase date and to attach tag to item before packing with your name,
complete address and phone number with a note giving purchase information,
model number and what you believe is the problem with item. We recommend you
insure the package (as damage in shipping is not covered by your warranty). Mark
the outside of your package “ATTENTION CUSTOMER SERVICE”. We are
constantly striving to improve our products, therefore the specifications
contained herein are subject to change without notice.
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
OWNERSHIP REGISTRATION CARD
Please fill out and mail the product registration card within ten (10) days of purchase. The
registration will enable us to contact you in the unlikely event of a product safety notification. By
returning this card you acknowledge to have read and understood the instructions for use, and
warnings set forth in the accompanying instructions.
RETURN TO EURO-PRO Operating LLC: 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901
For information or assistance:
EURO-PRO Operating LLC
94 Main Mill Street, Door 16
Plattsburgh, NY 12901
Model EP724H
Appliance model
______________________________________________________________________
______________________________________________________________________________
Date purchased
______________________________________________________________________________
Owner’s name
Name of store
Tel.: 1 (800) 798-7398
______________________________________________________________________________
Address
City
State
Postal Code
Printed in China
Download from Www.Somanuals.com. All Manuals Search And Download.
PROBLEM SOLVING
GETTING TO KNOW YOUR BAGLESS CYCLONIC
CANISTER
This appliance was inspected thoroughly and was in good operating condition
when it was shipped from the factory. If a minor problem occurs, it usually can
be solved quite easily when the cause is found. Therefore, this checklist is
provided for your convenience.
PROBLEM
POSSIBLE CAUSE
POSSIBLE
1. Not firmly plugged in.
2. No electricity in wall outlet.
3. On/Off switch not turned
on.
1. Plug in firmly, push on/off
switch to on.
2. Check fuse or breaker.
3. Push on/off switch to on
17
Cleaner Won’t
Run
4. Thermal protector tripped. 4. Reset thermal protector.
5. Blown fuse/tripped
breaker.
5. Reset circuit breaker or
replace fuse.
1. Full or clogged dust cup.
2. Clogged nozzle or dust
cup port.
3. Clogged hose.
4. Hole in hose.
1. Clean dust cup.
2. Remove obstruction.
3. Remove obstruction.
4. Replace hose.
Cleaner Won't
Pick Up
5. Hose not inserted fully.
6. Motor protection system
activated.
5. Push hose in securely.
6. Reset thermal protector.
7. Clean / change filters.
7. Dirty filters.
Small Air Driven
Turbo Brush
Does Not Rotate
Or Rotates
1. Rotating brush, turbine or
elbow obstructed.
2. Belt broken.
3. Hose obstructed.
4. HEPA filter clogged.
1. Clear obstructions.
2. Call 1 (800) 798-7398.
3. Clear obstruction.
4. Clean HEPA filter.
1. On/Off Button
2. Cord Rewind Button
3. Carrying Handle
4. Dust Cup
5. Dust Cup Cover
Slowly
6. Dust Cup Cover Release
7. Hose Connector Inlet
8. Hose Connector
9. Floor to Carpet Brush
10. Chrome Telescopic Tube
11. Curved Wand/Hose Extension
12. Flexible Hose
Air Flow
1. Attachment use restricts
airflow.
2. New carpet trimmings
clogging air passage.
Restricted With
Attachment Use
Sound Changes
1. Check attachment.
2. Remove obstruction.
13. Air Driven Turbo Brush
14. Crevice Tool
15. Upholstery Brush
16. Trap Door Release Button
17. Small Air Driven Turbo Brush
Technical Specifications
Main Unit:
Voltage:
Power:
120V., 60Hz.
10.3 Amps
2
9
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
PRECAUTIONARY MEASURES
Changing & Cleaning the
Pre-Motor Filter
Important: If the suction opening of the unit, the hose or the chrome telescopic tube
are BLOCKED, switch off the vacuum cleaner and remove the blocking
substance before you start the unit again.
Please Note: The HEPA Dust Cup
Filter is washable. It should, however,
be replaced every six (6) months to
ensure peak performance of your
vacuum.
The Post Motor Filter, Pre-Motor Filter
and Pre-Filter are washable. They
should however be replaced every six
(6) months to ensure peak performance
of your vacuum.
The pre-motor filter is located behind the
dust cup. See illustration below.
This is a rinseable filter but should be
replaced every six (6) months. Never
operate the vacuum without ALL the
filters in place.
4. When pulling out the power plug
from the wall outlet, pull the plug
not the power cord.
1. Do not operate the vacuum
cleaner too close to heaters or
radiators.
• Push the Power On/Off button to the
"Off" position and disconnect the
power cord from the wall outlet.
• Open the dust cup cover.
• Remove the pre-motor filter and rinse
in lukewarm water, let dry completely.
Do not use a washing machine to
rinse the filter. Do not use a hair dryer
to dry it. Air dry only.
Important: Make sure that ALL filters
are completely dry before re-installing
back in the hand vacuum.
Important: All filters should be checked
regularly for signs of damage,
preferably after each cleaning task. The
filters must be replaced immediately if
they become damaged. Always
disconnect the vacuum from the
electrical outlet when checking the
filters.
5. Do not pick up anything that is
burning or smoking such as
• When filter is completely dry, replace
pre-motor filter back into the unit and
close the dust cup cover.
2. Before inserting the power plug
into the wall outlet, make sure that
your hands are dry.
cigarettes, matches or hot ashes.
6. Do not use without all filters in place.
Cleaning Air Driven Turbo Brush
1. On the base of the turbo brush there is
an access door for the turbine. To
open for cleaning, push latch toward
door and lift door off.
2. Inspect turbine wheel and air passage
for debris and/or blockage. Remove
debris if present.
3. Inspect the rotating brush for built-up
hair or string. If present, remove by
carefully cutting with scissors. Avoid
damaging or cutting bristles.
4. Once clean, snap the turbine access
door back in place. The turbo brush
will not function without the access
door in place.
Note: This vacuum cleaner is equipped
with a plug and power cord that retract
automatically. If the cord or plug get
damaged, it must be replaced by a
qualified technician.
3. Before you start vacuuming,
make sure to remove large or
sharp objects that might
Warning: Hold the plug when
rewinding the cord. Do not allow the
cord to whip when rewinding.
damage the dust bag.
Changing & Cleaning the Post
Motor Filter
The post motor filter is a washable filter
but should be replaced every six (6)
months depending on usage. Never
operate the vacuum without ALL the
filters in place.
• Push the Power On/Off button to the
"Off" position and disconnect the
power cord from the wall outlet.
• The post motor filter is located on the
rear of the vacuum. Remove the filter
from the filter grill.
• Rinse in lukewarm water, let dry
completely. Do not use a washing
machine to rinse the filter. Do not use
a hair dryer to dry it. Air dry only.
• When filter is completely dry, replace
post motor filter back into the unit and
replace the filter cover.
3
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Assembling Your Vacuum Cleaner
9. Vigorously “TapClean”
the HEPA Dust Cup
Filter on a hard
surface until no more
dust is observed
falling out from
between the pleats of
the filter. See
IMPORTANT: Please note that there
4. Fitting the Floor to Carpet
is a safety switch inside the vacuum
where the dust cup is inserted to
prevent the unit from being run
without a dust cup filter in place. If the
dust cup filter has not engaged this
safety switch, the vacuum will NOT
operate. Therefore, ensure that the
dust cup filter is inserted firmly into the
vacuum when assembling.
Brush or the Air Driven Turbo
Brush to the Telescopic Tube
Note: Always remove the power plug
from the wall outlet before assembling or
removing accessories.
Push the telescopic tube into the
desired floor brush as show in the
illustration below.
1. Attaching the Flexible Hose
into the Vacuum
Connect the flexible hose into the
hose connector inlet. Push in until
you hear a “click”, indicating it is in its
locked position.
illustration at right.
Telescopic
Tube
PLEASE NOTE: The white pleated
filter material in the HEPA Dust Cup
Filter will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the HEPA
Changing & Cleaning the
Pre-Filter
The pre-filter is located on the top of the
Rinseable "TapClean" HEPA filter. See
illustration below.
This is a rinseable filter but should be
replaced every six (6) months. Never
operate the vacuum without ALL the
filters in place.
• Push the Power On/Off button to the
"Off" position and disconnect the
power cord from the wall outlet.
• Open the dust cup cover and remove
the dust cup being careful not to press
on the trap door release button.
• Remove the HEPA filter and hold the
tab that is on the top of the filter and
pull until the filter cover snaps off.
• Rinse pre-filter in lukewarm water, let
dry completely. Do not use a washing
machine to rinse the filter. Do not use
a hair dryer to dry it. Air dry only.
• Replace only when the pre-filter is
completely dry, replace into HEPA
filter and snap the cover back in
place.
2. Fitting the Chrome
Telescopic Tube to the
Curved Wand / Hose
Floor to Carpet
Nozzle
Dust Cup Filter
is properly
Fig. A
Wash
Extension
"TapCleaned”
after each use
and suction
once a
month or
when
suction
appears
reduced
5. Air Driven Turbo Brush
Push the chrome telescopic tube
into the curved wand / hose
extension, as shown in the
illustration below.
The efficiency of your Air Driven
Turbo Brush depends on the bristle
brush rotating at high speed. Strong
air suction is needed to accomplish
this. In order to ensure that
does not return
to 100%, then
we suggest that
the HEPA filter
be “TapCleaned”
vigorously until
no more dust
Warning: Allow 24
hours for drying before
replacing in unit.
maximum air suction is maintained,
please read the following instructions:
Empty the Dust Cup frequently during
use.
Always “TapClean” the HEPA dust
cup filter each time the dust cup is
emptied.
•
•
can be removed, then rinsed under
the faucet and allowed to dry for 24
hours before refitting into the vacuum.
(Fig. A) This should be done once a
month or when suction appears to
be reduced.
Important: The suction hole must be
open, free of any obstructions at all
times. Otherwise, the motor will overheat
and could become damaged.
3. Extending the Chrome
Telescopic Tube
•
•
Ensure that the rotating bristle brush
is kept free of hair and string.
Inspect the turbine regularly to ensure
that the air passage is free of dirt and
debris. See cleaning instructions on
page 8.
Push forward on the plastic button
and pull the inner chrome tube
outward.
10.Reassemble the debris screen to the
HEPA filter cartridge and replace into
dust cup (container). Ensure that the
filter assembly is completely seated
inside the dust cup (container).
Plastic
Button
Important: Do NOT use the HEPA filter
cartridge without the debris screen in
place.
11.Insert the Rinseable
"TapClean" HEPA dust cup
filter back into the dust cup.
12.Re-install dust cup into the
vacuum. Close cover and re-
attach hose.
Air Driven Turbo
Brush
4
7
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
4. Once clean, close the top cover of the
turbo brush and slide the locking latch
toward the rear of the brush to lock.
Small Air Driven Turbo Brush
Removing & Cleaning the
Rinseable "TapClean" HEPA
Dust Cup Filter
Warning: Always unplug the unit from
electrical outlet before removing the Dust
Cup (container).
7. After you have removed the
Rinseable "TapClean" HEPA dust
cup filter from the dust cup, separate
the debris screen from the HEPA filter
cartridge by holding the top rim of the
filter and twisting the debris screen
counterclockwise to unlock the debris
screen from the filter. Then lift the
debris screen to remove.
Warning: To reduce the risk of electric
shock, the power cord must be
disconnected before removing the dust
cup, HEPA filter,changing the filters or
performing maintenance/trouble shooting
checks.
The efficiency of your air driven turbo
brush depends on the bristle brush
rotating at high speed. Strong air suction
is needed to accomplish this. In order to
ensure that maximum air suction is
maintained, please read the following
instructions:
1. Empty the dust cup frequently.
2. Always shake out the dust cup filter
when emptying the dust cup container.
3. Ensure that the rotating brush is kept
free of hair and string which may
accumulate and decrease brush
performance.
4. Keep Air Driven Turbo Brush turbine
free of dirt and foreign matter. (See
illustration for cleaning instructions.)
To use the small air driven turbo brush,
remove the chrome telescopic tube from
the hose and insert the end of the hose
into the turbo brush.
Crevice Tool and Dusting Brush
1. Crevice Tool with Brush
For radiators, crevices,
corners, baseboards and
between cushions.
1. Push the Power
On/Off button to
"Off" and
2. Upholstery Brush
disconnect the
power cord from
the wall outlet.
The dusting brush is used
for the furniture
Using your Vacuum
2. Remove the
flexible hose.
3. Push the dust
cup cover release
button located
Note: Once all
attachments are
in place, unwind
a sufficient length
of cable and insert
the plug into the
wall outlet. A
8. Rinse the debris screen under the
faucet until clean. Allow to air dry or
dry with a clean dish towel. Do NOT
wash in dishwasher.
9. To replace the debris screen onto the
filter, slip the debris screen over the
filter and twist clockwise to lock in
place.
on the front
side of
the unit (see illustration) and lift
the cover up.
Fig. 1
yellow mark on the
power cord shows
4. Hold the dust cup by the handle
the ideal cable length. Don't pull the
power cord beyond the red mark.
1. Insert the power plug into the wall
outlet. (Fig. 1)
and lift it up out of the vacuum
5. Hold dust cup over a waste
basket (garbage can), lift cover
and then depress the trap door
release button to open the dust
cup. Dispose of the dust inside.
(See illustrations below.)
.
Warning: After each Use - Always
remove the Rinseable "TapClean" HEPA
Filter from the Dust Cup, then vigorously
“TapClean” HEPA Filter until no more
dust can be removed.
2. Press the Power
On/Off button
located on the
unit to turn the
Important: When "TapCleaning" the
HEPA filter, hold the HEPA filter from the
top rim and tap ONLY the bottom rim
against the side of the waste container.
NEVER tap directly on the pleated folds of
vacuum cleaner
Note: If dust is tightly packed and
difficult to remove, tap the side of
the dust cup lightly against the
side of the waste basket (garbage
can).
"On".
3. To rewind the
power cord,
Fig. 2
Cleaning the Small Air Driven
press the cord
the HEPA filter.
Top Rim
rewind button with one hand and hold
the plug of the power cord with the
other hand to ensure that it does not
whip causing damage or injury.
(Fig. 2)
Turbo Brush
Lift cover, then depress button
to open trap door
Locking Latch
Tilt
Upwards
Bottom Rim
Motor Thermostat
IMPORTANT, Please Note : The
Rinseable “TapClean” HEPA Dust Cup
Filter will stop most of the tiniest dust
particles from re-entering the air you
breathe. In fact it stops 99.97% of all
particles as small as 0.3 microns - many
times smaller than a human hair!!!
Because of this incredible filtration
performance, the HEPA Dust Cup Filter
will quickly accumulate dirt inside the
white filter folds, many fine dust particles
that are difficult to see but which will
eventually block or reduce your suction
power - if not cleaned properly. Clean the
HEPA Filter as described in this section,
then reconnect unit and proceed with
vacuuming.)
Important: This vacuum cleaner is
equipped with a motor protective
thermostat. If for some reason your
vacuum overheats, the thermostat will
automatically turn the unit off. Should this
occur, unplug the vacuum from the wall
outlet and turn off the switch. Empty the
dust cup, "TapClean" the dust cup filter
and check for blockages in hose and
suction inlet. Allow the unit to cool for a
minimum of 45 minimum prior to
Turbine
1. Slide locking latch forward then tilt the
top housing of the brush upwards. The
top housing is hinged and will tilt up
approximately 45° only.
2. Inspect turbine wheel and air passage
for debris and/or blockage. Remove
debris if present.
3. Inspect the rotating brush for built-up
hair or string. If present, remove by
carefully cutting with scissors. Avoid
damaging or cutting bristles.
6. To remove the
Rinseable "TapClean"
HEPA dust cup filter
from the dust cup,
hold the filter from
the tab at the top
of it and lift. See
restarting the unit. To restart, re-plug the
vacuum into the wall socket and turn the
switch back on
illustration at right.
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.
|