ONE (1) YEAR LIMITED WARRANTY  
EURO-PRO Operating LLC warrants this product to be free from defects in material  
and workmanship for a period of one (1) year from the date of the original purchase.  
This warranty applies only to normal domestic household use.  
Should your appliance fail to operate properly while in use under normal household  
conditions within the one (1) year warranty period, return the complete appliance and  
accessories, freight prepaid to EURO-PRO Operating LLC at the address given below.  
If the appliance is found to be defective in material or workmanship, EURO-PRO  
Operating LLC will repair or replace it free of charge. Proof of purchase date and  
$19.95 to cover the cost of return shipping and handling must be included.* Return to:  
Bagless Cyclonic Canister  
OWNER’S MANUAL  
EURO-PRO Operating LLC, 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901  
Model EP724H  
120V., 60Hz., 10.3 Amps  
Non-durable parts including, without limitation, rotating brushes and electrical parts  
which normally require replacement are specifically excluded from warranty.  
The liability of EURO-PRO Operating LLC is limited solely to the cost of the repair or  
replacement of the unit at our option. This warranty does not cover normal wear of parts  
and does not apply to any unit that has been tampered with or used for commercial  
purposes. This limited warranty does not cover damage caused by misuse, abuse,  
negligent handling or damage due to faulty packaging or mishandling in transit. This  
warranty does not cover damage or defects caused by or resulting from damages from  
shipping or repairs, service or alterations to the product or any of its parts, which have  
been performed by a repair person not authorized by EURO-PRO Operating LLC.  
This warranty is extended to the original purchaser of the unit and excludes all other  
legal and/or conventional warranties. The responsibility of EURO-PRO Operating LLC  
if any, is limited to the specific obligations expressly assumed by it under the terms of  
the limited warranty. In no event is EURO-PRO Operating LLC liable for incidental or  
consequential damages of any nature whatsoever. Some states do not permit the  
exclusion or limitation of incidental or consequential damages, so the above may not  
apply to you.  
This warranty gives you specific legal rights, and you may also have other rights which  
vary from state to state.  
*Important: Carefully pack item to avoid damage in shipping. Be sure to include  
proof of purchase date and to attach tag to item before packing with your name,  
complete address and phone number with a note giving purchase information,  
model number and what you believe is the problem with item. We recommend you  
insure the package (as damage in shipping is not covered by your warranty). Mark  
the outside of your package “ATTENTION CUSTOMER SERVICE”. We are  
constantly striving to improve our products, therefore the specifications  
contained herein are subject to change without notice.  
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy  
OWNERSHIP REGISTRATION CARD  
Please fill out and mail the product registration card within ten (10) days of purchase. The  
registration will enable us to contact you in the unlikely event of a product safety notification. By  
returning this card you acknowledge to have read and understood the instructions for use, and  
warnings set forth in the accompanying instructions.  
RETURN TO EURO-PRO Operating LLC: 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901  
For information or assistance:  
EURO-PRO Operating LLC  
94 Main Mill Street, Door 16  
Plattsburgh, NY 12901  
Model EP724H  
Appliance model  
______________________________________________________________________  
______________________________________________________________________________  
Date purchased  
______________________________________________________________________________  
Owner’s name  
Name of store  
Tel.: 1 (800) 798-7398  
______________________________________________________________________________  
Address  
City  
State  
Postal Code  
Printed in China  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROBLEM SOLVING  
GETTING TO KNOW YOUR BAGLESS CYCLONIC  
CANISTER  
This appliance was inspected thoroughly and was in good operating condition  
when it was shipped from the factory. If a minor problem occurs, it usually can  
be solved quite easily when the cause is found. Therefore, this checklist is  
provided for your convenience.  
PROBLEM  
POSSIBLE CAUSE  
POSSIBLE  
1. Not firmly plugged in.  
2. No electricity in wall outlet.  
3. On/Off switch not turned  
on.  
1. Plug in firmly, push on/off  
switch to on.  
2. Check fuse or breaker.  
3. Push on/off switch to on  
17  
Cleaner Won’t  
Run  
4. Thermal protector tripped. 4. Reset thermal protector.  
5. Blown fuse/tripped  
breaker.  
5. Reset circuit breaker or  
replace fuse.  
1. Full or clogged dust cup.  
2. Clogged nozzle or dust  
cup port.  
3. Clogged hose.  
4. Hole in hose.  
1. Clean dust cup.  
2. Remove obstruction.  
3. Remove obstruction.  
4. Replace hose.  
Cleaner Won't  
Pick Up  
5. Hose not inserted fully.  
6. Motor protection system  
activated.  
5. Push hose in securely.  
6. Reset thermal protector.  
7. Clean / change filters.  
7. Dirty filters.  
Small Air Driven  
Turbo Brush  
Does Not Rotate  
Or Rotates  
1. Rotating brush, turbine or  
elbow obstructed.  
2. Belt broken.  
3. Hose obstructed.  
4. HEPA filter clogged.  
1. Clear obstructions.  
2. Call 1 (800) 798-7398.  
3. Clear obstruction.  
4. Clean HEPA filter.  
1. On/Off Button  
2. Cord Rewind Button  
3. Carrying Handle  
4. Dust Cup  
5. Dust Cup Cover  
Slowly  
6. Dust Cup Cover Release  
7. Hose Connector Inlet  
8. Hose Connector  
9. Floor to Carpet Brush  
10. Chrome Telescopic Tube  
11. Curved Wand/Hose Extension  
12. Flexible Hose  
Air Flow  
1. Attachment use restricts  
airflow.  
2. New carpet trimmings  
clogging air passage.  
Restricted With  
Attachment Use  
Sound Changes  
1. Check attachment.  
2. Remove obstruction.  
13. Air Driven Turbo Brush  
14. Crevice Tool  
15. Upholstery Brush  
16. Trap Door Release Button  
17. Small Air Driven Turbo Brush  
Technical Specifications  
Main Unit:  
Voltage:  
Power:  
120V., 60Hz.  
10.3 Amps  
2
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
PRECAUTIONARY MEASURES  
Changing & Cleaning the  
Pre-Motor Filter  
Important: If the suction opening of the unit, the hose or the chrome telescopic tube  
are BLOCKED, switch off the vacuum cleaner and remove the blocking  
substance before you start the unit again.  
Please Note: The HEPA Dust Cup  
Filter is washable. It should, however,  
be replaced every six (6) months to  
ensure peak performance of your  
vacuum.  
The Post Motor Filter, Pre-Motor Filter  
and Pre-Filter are washable. They  
should however be replaced every six  
(6) months to ensure peak performance  
of your vacuum.  
The pre-motor filter is located behind the  
dust cup. See illustration below.  
This is a rinseable filter but should be  
replaced every six (6) months. Never  
operate the vacuum without ALL the  
filters in place.  
4. When pulling out the power plug  
from the wall outlet, pull the plug  
not the power cord.  
1. Do not operate the vacuum  
cleaner too close to heaters or  
radiators.  
• Push the Power On/Off button to the  
"Off" position and disconnect the  
power cord from the wall outlet.  
• Open the dust cup cover.  
• Remove the pre-motor filter and rinse  
in lukewarm water, let dry completely.  
Do not use a washing machine to  
rinse the filter. Do not use a hair dryer  
to dry it. Air dry only.  
Important: Make sure that ALL filters  
are completely dry before re-installing  
back in the hand vacuum.  
Important: All filters should be checked  
regularly for signs of damage,  
preferably after each cleaning task. The  
filters must be replaced immediately if  
they become damaged. Always  
disconnect the vacuum from the  
electrical outlet when checking the  
filters.  
5. Do not pick up anything that is  
burning or smoking such as  
• When filter is completely dry, replace  
pre-motor filter back into the unit and  
close the dust cup cover.  
2. Before inserting the power plug  
into the wall outlet, make sure that  
your hands are dry.  
cigarettes, matches or hot ashes.  
6. Do not use without all filters in place.  
Cleaning Air Driven Turbo Brush  
1. On the base of the turbo brush there is  
an access door for the turbine. To  
open for cleaning, push latch toward  
door and lift door off.  
2. Inspect turbine wheel and air passage  
for debris and/or blockage. Remove  
debris if present.  
3. Inspect the rotating brush for built-up  
hair or string. If present, remove by  
carefully cutting with scissors. Avoid  
damaging or cutting bristles.  
4. Once clean, snap the turbine access  
door back in place. The turbo brush  
will not function without the access  
door in place.  
Note: This vacuum cleaner is equipped  
with a plug and power cord that retract  
automatically. If the cord or plug get  
damaged, it must be replaced by a  
qualified technician.  
3. Before you start vacuuming,  
make sure to remove large or  
sharp objects that might  
Warning: Hold the plug when  
rewinding the cord. Do not allow the  
cord to whip when rewinding.  
damage the dust bag.  
Changing & Cleaning the Post  
Motor Filter  
The post motor filter is a washable filter  
but should be replaced every six (6)  
months depending on usage. Never  
operate the vacuum without ALL the  
filters in place.  
• Push the Power On/Off button to the  
"Off" position and disconnect the  
power cord from the wall outlet.  
• The post motor filter is located on the  
rear of the vacuum. Remove the filter  
from the filter grill.  
• Rinse in lukewarm water, let dry  
completely. Do not use a washing  
machine to rinse the filter. Do not use  
a hair dryer to dry it. Air dry only.  
• When filter is completely dry, replace  
post motor filter back into the unit and  
replace the filter cover.  
3
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
OPERATING INSTRUCTIONS  
Assembling Your Vacuum Cleaner  
9. Vigorously “TapClean”  
the HEPA Dust Cup  
Filter on a hard  
surface until no more  
dust is observed  
falling out from  
between the pleats of  
the filter. See  
IMPORTANT: Please note that there  
4. Fitting the Floor to Carpet  
is a safety switch inside the vacuum  
where the dust cup is inserted to  
prevent the unit from being run  
without a dust cup filter in place. If the  
dust cup filter has not engaged this  
safety switch, the vacuum will NOT  
operate. Therefore, ensure that the  
dust cup filter is inserted firmly into the  
vacuum when assembling.  
Brush or the Air Driven Turbo  
Brush to the Telescopic Tube  
Note: Always remove the power plug  
from the wall outlet before assembling or  
removing accessories.  
Push the telescopic tube into the  
desired floor brush as show in the  
illustration below.  
1. Attaching the Flexible Hose  
into the Vacuum  
Connect the flexible hose into the  
hose connector inlet. Push in until  
you hear a “click”, indicating it is in its  
locked position.  
illustration at right.  
Telescopic  
Tube  
PLEASE NOTE: The white pleated  
filter material in the HEPA Dust Cup  
Filter will discolor over time -This is  
NORMAL and will NOT affect the  
performance of the filter. If the HEPA  
Changing & Cleaning the  
Pre-Filter  
The pre-filter is located on the top of the  
Rinseable "TapClean" HEPA filter. See  
illustration below.  
This is a rinseable filter but should be  
replaced every six (6) months. Never  
operate the vacuum without ALL the  
filters in place.  
• Push the Power On/Off button to the  
"Off" position and disconnect the  
power cord from the wall outlet.  
• Open the dust cup cover and remove  
the dust cup being careful not to press  
on the trap door release button.  
• Remove the HEPA filter and hold the  
tab that is on the top of the filter and  
pull until the filter cover snaps off.  
• Rinse pre-filter in lukewarm water, let  
dry completely. Do not use a washing  
machine to rinse the filter. Do not use  
a hair dryer to dry it. Air dry only.  
• Replace only when the pre-filter is  
completely dry, replace into HEPA  
filter and snap the cover back in  
place.  
2. Fitting the Chrome  
Telescopic Tube to the  
Curved Wand / Hose  
Floor to Carpet  
Nozzle  
Dust Cup Filter  
is properly  
Fig. A  
Wash  
Extension  
"TapCleaned”  
after each use  
and suction  
once a  
month or  
when  
suction  
appears  
reduced  
5. Air Driven Turbo Brush  
Push the chrome telescopic tube  
into the curved wand / hose  
extension, as shown in the  
illustration below.  
The efficiency of your Air Driven  
Turbo Brush depends on the bristle  
brush rotating at high speed. Strong  
air suction is needed to accomplish  
this. In order to ensure that  
does not return  
to 100%, then  
we suggest that  
the HEPA filter  
be “TapCleaned”  
vigorously until  
no more dust  
Warning: Allow 24  
hours for drying before  
replacing in unit.  
maximum air suction is maintained,  
please read the following instructions:  
Empty the Dust Cup frequently during  
use.  
Always “TapClean” the HEPA dust  
cup filter each time the dust cup is  
emptied.  
can be removed, then rinsed under  
the faucet and allowed to dry for 24  
hours before refitting into the vacuum.  
(Fig. A) This should be done once a  
month or when suction appears to  
be reduced.  
Important: The suction hole must be  
open, free of any obstructions at all  
times. Otherwise, the motor will overheat  
and could become damaged.  
3. Extending the Chrome  
Telescopic Tube  
Ensure that the rotating bristle brush  
is kept free of hair and string.  
Inspect the turbine regularly to ensure  
that the air passage is free of dirt and  
debris. See cleaning instructions on  
page 8.  
Push forward on the plastic button  
and pull the inner chrome tube  
outward.  
10.Reassemble the debris screen to the  
HEPA filter cartridge and replace into  
dust cup (container). Ensure that the  
filter assembly is completely seated  
inside the dust cup (container).  
Plastic  
Button  
Important: Do NOT use the HEPA filter  
cartridge without the debris screen in  
place.  
11.Insert the Rinseable  
"TapClean" HEPA dust cup  
filter back into the dust cup.  
12.Re-install dust cup into the  
vacuum. Close cover and re-  
attach hose.  
Air Driven Turbo  
Brush  
4
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
OPERATING INSTRUCTIONS  
4. Once clean, close the top cover of the  
turbo brush and slide the locking latch  
toward the rear of the brush to lock.  
Small Air Driven Turbo Brush  
Removing & Cleaning the  
Rinseable "TapClean" HEPA  
Dust Cup Filter  
Warning: Always unplug the unit from  
electrical outlet before removing the Dust  
Cup (container).  
7. After you have removed the  
Rinseable "TapClean" HEPA dust  
cup filter from the dust cup, separate  
the debris screen from the HEPA filter  
cartridge by holding the top rim of the  
filter and twisting the debris screen  
counterclockwise to unlock the debris  
screen from the filter. Then lift the  
debris screen to remove.  
Warning: To reduce the risk of electric  
shock, the power cord must be  
disconnected before removing the dust  
cup, HEPA filter,changing the filters or  
performing maintenance/trouble shooting  
checks.  
The efficiency of your air driven turbo  
brush depends on the bristle brush  
rotating at high speed. Strong air suction  
is needed to accomplish this. In order to  
ensure that maximum air suction is  
maintained, please read the following  
instructions:  
1. Empty the dust cup frequently.  
2. Always shake out the dust cup filter  
when emptying the dust cup container.  
3. Ensure that the rotating brush is kept  
free of hair and string which may  
accumulate and decrease brush  
performance.  
4. Keep Air Driven Turbo Brush turbine  
free of dirt and foreign matter. (See  
illustration for cleaning instructions.)  
To use the small air driven turbo brush,  
remove the chrome telescopic tube from  
the hose and insert the end of the hose  
into the turbo brush.  
Crevice Tool and Dusting Brush  
1. Crevice Tool with Brush  
For radiators, crevices,  
corners, baseboards and  
between cushions.  
1. Push the Power  
On/Off button to  
"Off" and  
2. Upholstery Brush  
disconnect the  
power cord from  
the wall outlet.  
The dusting brush is used  
for the furniture  
Using your Vacuum  
2. Remove the  
flexible hose.  
3. Push the dust  
cup cover release  
button located  
Note: Once all  
attachments are  
in place, unwind  
a sufficient length  
of cable and insert  
the plug into the  
wall outlet. A  
8. Rinse the debris screen under the  
faucet until clean. Allow to air dry or  
dry with a clean dish towel. Do NOT  
wash in dishwasher.  
9. To replace the debris screen onto the  
filter, slip the debris screen over the  
filter and twist clockwise to lock in  
place.  
on the front  
side of  
the unit (see illustration) and lift  
the cover up.  
Fig. 1  
yellow mark on the  
power cord shows  
4. Hold the dust cup by the handle  
the ideal cable length. Don't pull the  
power cord beyond the red mark.  
1. Insert the power plug into the wall  
outlet. (Fig. 1)  
and lift it up out of the vacuum  
5. Hold dust cup over a waste  
basket (garbage can), lift cover  
and then depress the trap door  
release button to open the dust  
cup. Dispose of the dust inside.  
(See illustrations below.)  
.
Warning: After each Use - Always  
remove the Rinseable "TapClean" HEPA  
Filter from the Dust Cup, then vigorously  
TapClean” HEPA Filter until no more  
dust can be removed.  
2. Press the Power  
On/Off button  
located on the  
unit to turn the  
Important: When "TapCleaning" the  
HEPA filter, hold the HEPA filter from the  
top rim and tap ONLY the bottom rim  
against the side of the waste container.  
NEVER tap directly on the pleated folds of  
vacuum cleaner  
Note: If dust is tightly packed and  
difficult to remove, tap the side of  
the dust cup lightly against the  
side of the waste basket (garbage  
can).  
"On".  
3. To rewind the  
power cord,  
Fig. 2  
Cleaning the Small Air Driven  
press the cord  
the HEPA filter.  
Top Rim  
rewind button with one hand and hold  
the plug of the power cord with the  
other hand to ensure that it does not  
whip causing damage or injury.  
(Fig. 2)  
Turbo Brush  
Lift cover, then depress button  
to open trap door  
Locking Latch  
Tilt  
Upwards  
Bottom Rim  
Motor Thermostat  
IMPORTANT, Please Note : The  
Rinseable “TapClean” HEPA Dust Cup  
Filter will stop most of the tiniest dust  
particles from re-entering the air you  
breathe. In fact it stops 99.97% of all  
particles as small as 0.3 microns - many  
times smaller than a human hair!!!  
Because of this incredible filtration  
performance, the HEPA Dust Cup Filter  
will quickly accumulate dirt inside the  
white filter folds, many fine dust particles  
that are difficult to see but which will  
eventually block or reduce your suction  
power - if not cleaned properly. Clean the  
HEPA Filter as described in this section,  
then reconnect unit and proceed with  
vacuuming.)  
Important: This vacuum cleaner is  
equipped with a motor protective  
thermostat. If for some reason your  
vacuum overheats, the thermostat will  
automatically turn the unit off. Should this  
occur, unplug the vacuum from the wall  
outlet and turn off the switch. Empty the  
dust cup, "TapClean" the dust cup filter  
and check for blockages in hose and  
suction inlet. Allow the unit to cool for a  
minimum of 45 minimum prior to  
Turbine  
1. Slide locking latch forward then tilt the  
top housing of the brush upwards. The  
top housing is hinged and will tilt up  
approximately 45° only.  
2. Inspect turbine wheel and air passage  
for debris and/or blockage. Remove  
debris if present.  
3. Inspect the rotating brush for built-up  
hair or string. If present, remove by  
carefully cutting with scissors. Avoid  
damaging or cutting bristles.  
6. To remove the  
Rinseable "TapClean"  
HEPA dust cup filter  
from the dust cup,  
hold the filter from  
the tab at the top  
of it and lift. See  
restarting the unit. To restart, re-plug the  
vacuum into the wall socket and turn the  
switch back on  
illustration at right.  
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

Dynex TV DVD Combo DX PD510 User Manual
Extron electronic Stereo System RG59 3MHR 3 User Manual
Fujitsu Flat Panel Television P42HCA10 User Manual
Fujitsu Scanner C150 E062 04EN User Manual
Fusionbrands Home Theater System MS FR402 User Manual
Gemini DJ Equipment MM 3000 User Manual
GE Monogram Dishwasher ZBD68XXK User Manual
Genius Clock Radio GEO 1 User Manual
GE Ventilation Hood ZVB36BN User Manual
Gianni Industries Door DG 12 User Manual