Estate Range TGP200VD User Manual

20" (50.8 cm) Freestanding Gas Range  
PRODUCT MODEL NUMBERS  
PRODUCT DIMENSIONS  
TGP200VD  
Gas supply: Provide a gas supply line of 3/4" (1.9 cm) rigid  
pipe to the range location. A smaller size pipe on longer runs  
may result in insufficient gas supply. Pipe joint compounds  
that resist the action of LP gas must be used. Do not use  
TEFLON®† tape. With LP gas, piping or tubing size can be 1/2"  
(1.3 cm) minimum. Usually, LP gas suppliers determine the  
size and materials used in the system.  
If local codes permit, a new CSA design-certified, 4-5 ft  
(122-152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D.,  
flexible metal appliance connector may be used for connecting  
range to the gas supply line.  
42"  
(106.7 cm)  
36"  
(91.5 cm)  
A 1/2" (1.3 cm) male pipe thread is needed for connection to  
the female pipe threads of the inlet to the appliance gas  
pressure regulator.  
Must include a shutoff valve:  
The supply line must be equipped with a manual shutoff valve.  
This valve should be located in the same room but external to  
the range. It should be in a location that allows ease of opening  
and closing.  
Electrical: A 120-volt, 60-Hz, AC-only, 15-amp, fused  
electrical circuit is required. A time-delay fuse or circuit breaker  
is also recommended. It is recommended that a separate  
circuit serving only this range be provided.  
24 1/2"  
(62.2 cm)  
19 1/2"  
(49.5 cm)  
Do not use an extension cord.  
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and  
Company.  
CABINET OPENING DIMENSIONS  
13" (33.0 cm) max.  
upper cabinet depth  
20" (50.8 cm) min.  
For minimum  
cabinet opening width  
clearance to  
top of cooktop,  
see NOTE  
Cabinet opening dimensions shown are for 25" (64 cm) countertop  
depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop  
height.  
20 1/8" (51.12 cm)  
opening width  
18" (45.7 cm)  
min. clearance  
upper side  
cabinet to  
3" (7.6 cm) min.  
countertop space to  
side wall or other  
combustible material  
If the cabinet depth is greater than 24" (61 cm), the oven frame must  
extend beyond cabinet fronts by 1/2" (13 mm) minimum.  
countertop  
This shaded area  
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is  
protected by not less than 1/4" (0.64 cm) flame retardant millboard  
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)  
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.  
recommended for  
installation  
of gas pipe  
10" (25.4 cm)  
30" (76.2 cm) minimum clearance between the top of the cooking  
platform and the bottom of an unprotected wood or metal cabinet.  
IMPORTANT: If installing a range hood or microwave hood  
combination above the range, follow the range hood or microwave hood  
combination installation instructions for dimensional clearances above  
the cooktop surface.  
5 1/2"  
(14 cm)  
4"  
(10 cm)  
2"  
(5.1 cm)  
2 1/2"  
(6.4 cm)  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10173324  
09-05-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki CRT Television LC XWP2000 User Manual
Electro Voice Musical Instrument Amplifier DH2A User Manual
Fluke Child Tracker 90100 User Manual
Fluke Thermometer 07 402 User Manual
Ford Automobile 2010 Transit Connect User Manual
Frigidaire Air Conditioner FRA123KT1 User Manual
Frigidaire Double Oven FGET3045K User Manual
Fujitsu Printer FTP 632MCL101 User Manual
GE Universal Remote 90 30 20 Micro User Manual
Gigabyte Computer Hardware AGP 4X15V User Manual