		 Gas Dryer   
					PRODUCT MODEL NUMBERS   
					OVERALL DIMENSIONS   
					EGD4100S   
					EGD4300S   
					EGD4400S   
					TGDS740P   
					TGDS840P   
					TGDX540R   
					TGDX640P   
					A. Small Opening   
					Side-Swing Door   
					Gas supply: Dryer is equipped for use with   
					NATURAL gas. Dryer can be converted to L.P. gas.   
					When rigid pipe is used it should be 1/2 inch IPS.   
					When acceptable to the gas supplier and local   
					codes, 3/8-inch approved tubing may be used for   
					lengths under 20 feet. For lengths over 20 feet,   
					larger tubing should be used. Pipe-joint   
					B. Large Opening   
					Side-Swing Door   
					compounds resistant to the action of L.P. gas must   
					be used. If local codes permit, it is recommended   
					that new flexible metal tubing, design-certified by   
					AGA or CSA, be used for connecting the appliance   
					to the rigid gas supply line. (The gas pipe which   
					extends through the lower rear of the appliance   
					has 3/8-inch male pipe thread.) An individual   
					manual shutoff valve must be installed within 6   
					feet of the dryer in accordance with the National   
					Fuel Gas Code ANSI Z223.1.   
					A 
					B 
					C. Wided Opening   
					Side-Swing Door   
					D. Wide Opening   
					Hamper Door   
					Electrical: A four-wire or three-wire, single   
					phase, 120-volt, 60 Hz, AC-only, electrical supply   
					is required on a separate 15 or 20 amp circuit,   
					fused on both sides of the line. A time-delay fuse   
					or circuit breaker is recommended.   
					C 
					D 
					Exhaust venting: Exhaust your dryer to the   
					outside. Four-inch diameter vent is required. Rigid   
					or flexible metal exhaust vent must be used. Do   
					Not use plastic or metal foil vent. Exhaust outlet   
					hood must be at least 12 inches from the ground   
					or any object that may be in the path of the   
					exhaust.   
					RECESSED AREA AND CLOSET INSTALLATION   
					" 
					For closet installation   
					with a door, minimum   
					ventilation openings in   
					" 
					" 
					" 
					" 
					the top and bottom of   
					the door are required.   
					Louvered doors with   
					equivalent air openings   
					are acceptable.   
					" 
					51   
					" 
					2 
					29"   
					(73.66 cm)   
					" 
					27   
					" 
					" 
					4 
					" 
					(70.5 cm) (14 cm)   
					A 
					B 
					C 
					A. Recessed area   
					B. Side view - closet or confined area   
					C. Closet door with vents   
					EXHAUST VENTING   
					4"   
					(10.2 cm)   
					Box hood style   
					1. Select the route that will provide the straightest and most direct path outdoors. Plan   
					the installation to use the fewest number of elbows and turns. When using elbows or   
					making turns, allow as much room as possible. Bend vent gradually to avoid kinking.   
					Avoid 90° turns.   
					4"   
					(10.2 cm)   
					2.5"   
					(6.4 cm)   
					4"   
					(10.2 cm)   
					Angled style   
					Louvered style   
					Vent Length Chart   
					2. Determine vent length.   
					The maximum length of the exhaust system depends upon:   
					• The type of vent (rigid metal or flexible metal).   
					• The number of elbows used.   
					• Type of hood.   
					See the exhaust vent length chart that matches your hood type for the maximum vent   
					lengths you can use.   
					3. Determine the number of elbows you will need.   
					IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.   
					In the column listing the type of metal vent you are using (rigid metal or flexible metal),   
					find the maximum length of metal vent on the same line as the number of elbows.   
					Number of   
					90° turns   
					or elbows   
					Type of   
					vent   
					Box or   
					Louvered   
					hoods   
					Angled   
					hoods   
					0 
					1 
					2 
					3 
					4 
					Rigid metal   
					64 ft (20 m)   
					58 ft (17.7 m)   
					28 ft (8.5 m)   
					Flexible metal 36 ft (11 m)   
					Rigid metal   
					Flexible metal   
					54 ft (16.5 m)   
					31 ft (9.4 m)   
					48 ft (14.6 m)   
					23 ft (7 m)   
					Rigid metal   
					Flexible metal 27 ft (8.2 m)   
					44 ft (13.4 m) 38 ft (11.6 m)   
					19 ft (5.8 m)   
					Rigid metal   
					Flexible metal 25 ft (7.6 m)   
					35 ft (10.7 m) 29 ft (8.8 m)   
					17 ft (5.2 m)   
					Rigid metal   
					Flexible metal 23 ft (7 m)   
					27 ft (8.2 m)   
					21 ft (6.4 m)   
					15 ft (4.6 m)   
					Because Whirlpool Corporation policy includes a continuous commitment to improve   
					our products, we reserve the right to change materials and specifications without notice.   
					Dimensions are for planning purposes only. For complete details, see Installation   
					Instructions packed with product. Specifications subject to change without notice.   
					Ref. 8562589   
					09-11-06   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |