ETA Systems Surge Protector ETA ECM30 User Manual

ETA-ECM30  
30A AC Power Module Spike Suppressor  
ETA-ECM30  
30A AC Power Module  
Spike Suppressor  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 1 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
IMPORTANT SAFETY INSTRUCTIONS  
The lightning flash with arrowhead symbol within an  
equilateral triangle, is intended to alert the user to the  
presence of uninsulated “dangerous voltage “ within the  
product’s enclosure that may be of sufficient magnitude  
to constitute a risk of electric shock to persons.  
The exclamation point within an equilateral triangle is  
intended to alert the user to the presence of important  
operating and maintenance (servicing) instructions in the  
literature accompanying the product.  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this device near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.  
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other device (including amplifiers)  
that produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the  
other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your  
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they  
exit from the device.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used,  
use caution when moving the cart/device combination to avoid injury from tip-over.  
13. Unplug this device during lightning storms or when unused for long periods of time.  
14. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as  
power-supply cord or plug is damaged, liquid has been spilled, or objects have fallen into the device, the device has been exposed  
to rain or moisture, does not operate normally, or has been dropped.  
15. WARNING: To reduce the risk of fire or electric shock, this device should not be exposed to rain or moisture and objects filled with  
liquids, such as a vase, should not be placed on this device.  
16. To completely disconnect this equipment from the mains, disconnect the power supply cord plug from the receptacle.  
17. The mains plug of the power supply cord shall remain readily operable.  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 3 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
WARNING – WHEN THE DEVICE IS IN USE  
To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to  
ETA Systems.  
Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the  
AC outlet and contact ETA Systems. Do not to attempt to continue operation with the product as this may cause fire or electric shock:  
Smoke or strange smell coming from the unit.  
If the product falls or the case is damaged.  
If water or any metallic objects falls into the product.  
If the power supply cord is damaged in any way.  
If the unit is malfunctioning.  
Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in  
electric shock or fire.  
Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric  
shock may result.  
Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.  
Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result.  
Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used.  
Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects  
on the power cord, including the product itself, doing so may result in fire or electrical shock.  
Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic  
disaster may result.  
Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.  
CAUTION – WHEN INSTALLING THE PRODUCT  
Plugging in or unplugging the power cord with wet hands may result in electric shock.  
Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.  
When unplugging the cord from the wall, grasp the plug, NOT the cord.  
Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or  
steam are present. Fire and electric shock may result.  
Keep all sides of the unit at least 312" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.  
CAUTION – WHEN THE DEVICE IS IN USE  
Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In  
addition, the product itself may fall and cause injury and property damage.  
Contact ETA Systems for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat  
buildup and fire.  
Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or  
inside the wall outlet.  
When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 4 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
INTRODUCTION  
Thank you for purchasing the ETA Systems ETA-ECM30 AC Power Module Spike Suppressor Unit. Note: For your safety, all electrical  
wiring should be done by a qualified electrician.  
The ETA Systems ETA-ECM30 is an Electrical Control Module (ECM) 30A AC Spike Suppressor that is designed to be used as a  
stand-alone unit or in conjunction with an ETA-ECS6RM Controller up to 1000ft away. AC Spikes, or transients, are commonly caused  
by utility power plant grid switchovers. The amount of energy that can be injected into the power system can be immense with  
voltages reaching 6kV or current peaks of 3000A. These spikes are very fast and usually only last for a very short period of time. To  
protect against this potential problem, incoming AC Mains have special suppression circuitry to eliminate the unwanted energy. The  
ETA-ECM30 circuitry is very fast and can suppress unwanted energy within a nanosecond, while sustaining the suppression for up to 2  
milliseconds, thus ensuring virtually trouble-free protection.  
High and low AC Main line voltages are another major contributor to equipment failures. The ECM modules support Extreme Voltage  
Shutdown (EVS) circuitry when used with an ETA-ECS6RM controller, which enables the module to be shut Off during high and low AC  
line conditions. High line voltages or surges usually are a slower steady state rise in voltages ranging from 128VAC and up. They can  
be caused by fluctuations in the utility company’s power lines or by industrial equipment turning On and Off when it is on the same  
power leg of the building’s incoming AC. Low line voltages or brownouts occur when the AC Mains drops below 107VAC. Most of the  
time it is caused by the utility company not being able to supply enough power during heavy utility consumption time periods, such as  
heat waves. Another factor can be from voltage drops in AC lines due to long transmissions. The ETA-ECS6RM will inform you if any of  
these conditions occur. Extreme variances in unstable AC Mains voltage are one of the main reasons for equipment failure.  
KEY FEATURES  
Manual/Auto On/Off Switch  
Incoming AC Present LED  
Active LED  
AC Fault LED  
Clamping Spike & Surge Suppression EVS Circuitry  
AC Mains Voltage Monitoring  
APPLICATIONS  
The following are just a few examples of applications where the ETA-ECM30 can be used:  
Restaurants  
Houses of Worship  
Schools  
Home Theaters  
Office Buildings  
Sports Bars  
Industrial Facilities  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 5 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
FRONT PANEL FEATURES  
3
4
5
A
C
E
B
D
1
2
6
1. Trigger/Status Port Pin Identification  
All signals are of low voltage and current. DO NOT MISS WIRE or damage may occur.  
A. (+) requires a minimum of 5–24V DC to activate the module with 5mA of current. Note: The DCV can be supplied from any  
source. The EVS protection requires the ETA-ECS6RM for operation.  
B. G = Circuit Ground. Must be of the same circuit as the DCV source.  
C. V = AC Voltage Status Signal. Reports the Incoming AC Mains Voltage to the ECM module back to the ETA-ECS6RM.  
D. NC = No Connection  
E. D = Fault Status Signal. Reports any fault conditions of an ECM module to the ETA-ECS6RM.  
2. External Trigger/Manual On Switch  
The ETA-ECM30 has a manual override switch allowing it to be used as a local Spike Suppressor. For remote monitoring and activation,  
the switch must be in the “External Trigger” position.  
3. Active LED  
This LED will illuminate Green when the ECM module has sensed the proper DCV to activate the unit. Note: If the ETA-ECM30 is  
connected to the ETA-ECS6RM and the EVS circuit has been activated, this LED will not be lit. The Channel Status LED on the  
ETA-ECS6RM will flash indicating a problem and the ECM module will not turn On until the AC Mains voltage is stable.  
4. AC Fault LED  
If damage to the Spike Suppression circuit occurs, this LED will illuminate Red. The module may still operate but may not be protecting  
the items plugged into the AC outlets. The ECM module should be inspected and repaired by a qualified technician.  
5. Incoming AC LED  
This LED will illuminate Red when the ECM has incoming AC power present at the module. This LED must be On to operate.  
Note: If this LED is not illuminating check the following: 1) the unit is plugged in, 2) the AC Mains Breaker feeding the AC leg to the  
ECM module is Off, 3) the internal fuse has been damaged. This should only be inspected by an authorized technician.  
6. AC Mains Outlet  
120V 30A L5-30 Receptacle  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 6 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
ECM HOUSING TYPES  
ECM-RACEWY1  
ECM-RACEWY3  
ECM-RACEWY1  
ECM-RACEWY3  
ECM-RACEWY6  
The ETA-ECM30 requires an electrical housing. These housings are manufactured by Atlas Sound and are available through ETA  
Systems. The ECM-RACEWY1 holds 1 ECM module, the ECM-RACEWY3 holds up to three ECM modules, and the ECM-RACEWY6  
holds up to six ECM modules. Three standard ¾" and 1" electrical knockouts on the bottom of each raceway and a distribution area  
with cover plate supports standard electrical mounting hardware. Note: All electrical wiring should be done by a certified electrician.  
ECM-3BP Module Cover Plate  
The ECM-RACEWY3 can hold up to three ETA-ECM20/30 Modules and the ECM-RACEWY6 can hold up to six ETA-ECM20/30  
Modules. If using fewer modules than the housing will hold, the open slots can be covered using an ECM Module Blank Plate. Two of  
these are included with the ECM-RACEWY6. If additional Blank Plates are required, they can be purchased in packages of three.  
All cover plates must be secured tightly. For safety, there should be no open slots when the raceway is in use. Top and bottom  
mounting tabs are incorporated to mount inside an Atlas Rack. All rack mount rails are designed to be removed if they are not needed;  
simply bend the tab back and forth until the tab breaks. Be careful of sharp edges.  
ECM Data Wire and Distance  
There are six ECM control ports on the ETA-ECS6RM and up to six ECM Modules can be connected to it. There are many types of ECM  
Modules that require the same interface connectivity to the ETA-ECS6RM. All ECM Modules can be interfaced with the  
ETA-ECS6RM. For connection between the ETA-ECS6RM and an ECM module, use a 5 conductor cable that is a minimum of 22 gauge  
wire. It is recommended to use CAT5 cable due to the common availability and low cost. Pay special attention to the port connections  
and DO NOT MISS WIRE or damage may occur. The distance between the ETA-ECS6RM and the ECM Module can be up to 1000ft.  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 7 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
ECM MODULE ACTIVATION WITHOUT USING AN ETA-ECS6RM CONTROLLER  
Any of the ECM Modules can be triggered remotely to activate without using an ECS type Controller. If you do not need the features of  
the ECS controllers, remote activation can be accomplished by applying DC external voltage or by hard switch contacts. Note: The EVS  
and Voltage monitoring will be disabled when not using an ECS controller.  
Remote DC Voltage Trigger  
(+) requires a minimum of 5–24VDC to activate the module with  
5mA of current. The DVC can be supplied from any source.  
Note: The EVS and Voltage monitoring will be disabled  
G=Circuit Ground. Must be of the same circuit as the DCV source.  
Remote Hard Switch Contact Trigger  
An external hard switch will also activate an ECM module by applying  
a contact to short terminals “+” and “D” together.  
Note: The EVS and Voltage monitoring will be disabled.  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 8 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
WIRING THE ETA-ECM30 CONTROL MODULE  
The ETA-ECM30 is designed to be inserted in the ECM-RACEWY1, ECM-RACEWY3, or ECM-RACEWY6 housing. The specific job  
(install) AC power requirements and power distribution layout will dictate how the ECM modules are wired into the housing. The  
ETA-ECM30 Module can be wired as a single 30A run or in a parallel (loop thru) configuration. Each ECM module has dual 3-position  
screw terminal blocks that are in parallel and are clearly labeled as follow: E - Green = Ground, L - Black = Load, N - White = Neutral. Use  
a minimum of 10 gauge wire for a 30A rating. Follow all local electrical codes. All installation must be done by a certified electrician.  
Secure Wire via  
Screw Terminal  
Green  
Black  
White  
AC Loop Thru  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 9 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
ETA-ECM30 SPECIFICATIONS  
Type  
AC Power Module Spike Suppressor  
Yes  
RoHS Compliant  
Safety Listings  
ETL (UL 60065 Standard)  
Front Panel  
Outlet  
Single 30A, L5-30  
Indicators  
Active (Green), Fault (Red), Incoming AC (Red)  
Slide Switch  
External Trigger/Manual On  
Connectors  
5 Position Phoenix Euro Block Style  
SPST Contact  
Hard Switch Remote Trigger  
Status Signals  
Output for Voltage (When used with ECM-6RM)  
Screw Terminal Block  
AC Mains Interconnect  
Technical Data  
Current Rating  
30A  
Operating Voltage  
102VAC - 132VAC  
Power Consumption  
500 milliwatts  
Power Requirements  
120V 60Hz  
Extreme Voltage Shutdown  
DCV Remote Trigger  
(EVS) Below 102V or above 132V AC Line (When used with ETA-ECS6RM)  
5-24DCV  
High Voltage Surge Protection  
Low Voltage Surge Protection  
Spike and Surge Suppression  
Spike Protection Modes  
Min. Spike Clamping Voltage  
Max. Spike Clamping Voltage  
Max. Spike Clamping Resp. Time  
Spike Clamping Voltage @ 100A  
Maximum Surge Current  
Energy Rating  
Trigger at 133VAC, 1ms typically (When used with ETA-ECS6RM)  
Trigger at 101VAC, 1ms typically (When used with ETA-ECS6RM)  
Hot to Neutral, Hot to Ground, Neutral to Ground  
Circuitry on Incoming AC Mains  
460 VRMS @ 3,000 amps  
6kV  
<1 nanosecond  
1,250Vp for 20µs  
6,500A  
600 Joules  
Temperature Range  
5° – 35°C  
Humidity Range  
5% to 95% R.H.  
Mechanical  
Chassis Finish  
Mounting  
Height  
Black  
#8 516" Self Tapping Screws  
3" (76.2mm)  
Width  
3.5" (88.9mm)  
8.5" (215.9mm)  
1.25 lbs (0.68kg)  
Length  
Weight  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 10 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
NOTES:  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 11 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ETA-ECM30  
30A AC Power Module Spike Suppressor  
LIMITED WARRANTY  
All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or commercial purchaser to be  
free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty  
shall extend from the date of purchase for a period of one year. Additionally, fuses and lamps carry no warranty. ETA Systems will  
solely at its discretion, replace at no charge or repair free of charge defective parts or products when the product has been applied  
and used in accordance with our published operation and installation instructions. We will not be responsible for defects caused by  
improper storage, misuse (including failure to provide reasonable and necessary maintenance), accident, abnormal atmospheres, water  
immersion, lightning discharge, or malfunctions when products have been modified or operated in excess of rated power, altered,  
serviced or installed in other than a workmanlike manner. The original sales invoice should be retained as evidence of purchase under  
the terms of this warranty. All warranty returns must comply with our returns policy set forth below. When products returned to ETA  
Systems do not qualify for repair or replacement under our warranty, repairs may be performed at prevailing costs for material and labor  
unless there is included with the returned product(s) a written request for an estimate of repair costs before any non-warranty work is  
performed. In the event of replacement or upon completion of repairs, return shipment will be made with the transportation charges  
collect.  
EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL  
INJURY, ETA SYSTEMS SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL OR INCIDENTAL  
LOSS OR DAMAGE ARISING OUT OF THE INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS. THE ABOVE WARRANTY IS  
IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE.  
ETA Systems does not assume, nor does it authorize any other person to assume or extend on its behalf, any other warranty,  
obligation, or liability. This warranty gives you specific legal rights and you may have other rights which vary from state to state.  
SERVICE  
Should your ETA-ECM30 require service, please contact the ETA Systems warranty department at  
1-877-689-8055, ext. 277 to obtain an RA number.  
ETA Systems Tech Support can be reached at 1-800-321-6699.  
©2012 ETA Systems. All rights reserved. All other trademarks are the property of their respective owners. ETA004089 RevC 2/12  
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.  
Telephone: 800-321-6699 • Fax: 800-996-3821  
– 12 –  
ETAsys.com  
Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Exabyte Computer Drive EXB 8505 8mm User Manual
Fender Stereo Amplifier 1970 Relic Stratocaster User Manual
Festool Sander RAS 11504 E User Manual
Flymo Blower 2700XV User Manual
Furuno Radar Detector CSH 53 User Manual
Gaggenau Refrigerator RF 411 User Manual
Garland Range PS 12G 2 20 User Manual
GE Monogram Microwave Oven ZEM200 User Manual
Generac Power Systems Portable Generator 0784 1 User Manual
GE Ventilation Hood ZVB30 User Manual