Zoneline. Efficient. Quiet.  
Reliable. Innovative.  
Versatile Zoneline® Packaged Terminal Air Conditioners provide year-round comfort  
with individual heating and cooling temperature controls. Designed for a wide range of  
applications, these units are ideal for hotels and motels, office buildings, schools and  
apartments. All Zoneline units feature the exclusive GE® “Superseal” system which  
minimizes energy usage by reducing air infiltration. The result is maximum operating  
efficiency and a more comfortable room. All Zoneline units are also very quiet thanks to a  
lower sound level and lower sound transmission. The newest innovation in Zoneline units  
is the Dry Air ꢀ5 Series. Similar to our Deluxe ꢀ900 Series, the Dry Air ꢀ5 removes ꢀ5%  
more moisture from the air than standard GE packaged terminal air conditioners.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Zoneline® features and benefits  
Electronic touch controls  
The ꢀ900, ꢁ900 and 5800 Series Zoneline® units are  
equipped with microcomputer touch controls. This  
Central desk control  
All Zoneline units are compatible with two-wire central  
desk ON/OFF controls, including many computerized  
feature gives the user better control over the temperature control systems. They can also be wired directly to  
with a touch pad and an LED readout.  
infrared sensors and door switches to maximize efficiency.  
Remote installation capability  
Optional corrosion treatment  
All Zoneline units are compatible with GE® wall-mounted  
remote thermostats. Mechanical, digital and programmable  
thermostats are available.  
Deluxe Zoneline units can be ordered with special  
treatment to reduce the effects of corrosive  
environments. Special treatments are placed on  
the outdoor coil and other components to extend  
the life of the unit.  
Model shown: PDW9880J  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ge.com  
The Dry Air ꢀ5  
Freeze Sentinel™  
The Dry Air ꢀ5 Series centers around GE’s exclusive use of  
the patented Dinh® Dehumidifier Heat Pipe from Heat Pipe  
Technology, Inc. This innovative technology enables the  
Dry Air ꢀ5 to remove ꢀ5% more moisture from the air than  
standard GE packaged terminal air conditioners. The Dry Air  
ꢀ5 is perfect for high-humidity climates. Available on 7000,  
9000 and 1ꢀ000 BTU models.  
All Zoneline units are equipped with Freeze Sentinel to  
provide protection against damage caused by freezing  
temperatures in unoccupied rooms, regardless of unit  
setting. In installations where freezing temperature is  
not a concern, the owner has the option of disabling  
the Freeze Sentinel.  
Heat Sentinel  
Upfront filters  
Provides automatic protection against overheating by  
switching on the unit to cool should the temperature  
of an unoccupied room reach 85°F.  
For ease of cleaning, all Zoneline units have interchangeable,  
removable upfront filters made of long-lasting nylon mesh,  
thus assuring high performance and long life.  
Electronic temperature limiting  
Heating and cooling temperatures may be electronically  
limited on all series to prevent expensive overcooling or  
overheating. Heating and cooling limits are independently  
set so seasonal adjustment is unnecessary.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Easy installation and flexibility of design  
Wall sleeve (optional)  
RAB71A (Shown)  
RAB77Aꢂ (SMC) (Not Shown)  
Zoneline® units are designed with innovative, universal  
components, and offer even greater installation flexibility  
than ever, whether in new construction, renovation or  
for replacement of old units. Unless specified by code,  
they require no sub-base and may be installed flush with  
finished floor. All models are adaptable to remote and  
central desk control. Zoneline units may even be placed  
in unusual locations, such as transom or common-area  
installations. The two lines, Deluxe and Premium, each  
with its own special blend of features, offer flexibility to  
meet each zone application. All units come with  
microcomputer controls.  
Room cabinet  
Deluxe ꢀ900 series  
Deluxe Dry Air ꢀ5 series  
Deluxe ꢁ900 series  
cooling with resistance heat  
cooling with resistance heat  
cooling with heat pump  
and resistance heat  
• Digital controls  
Includes all features of ꢀ900 series, plus:  
- LED temperature display  
- Easy temperature selection  
- Tactile touch pads  
• Two fan motors  
- Improved quiet sound levels  
- Higher efficiency  
• Electronic temperature limiting  
- Helps reduce operating costs  
• Optional corrosion treatment  
- Reduces the effects of coastal  
environments  
• Freeze Sentinel™  
- Protects unoccupied rooms from  
damage by freezing temperatures  
• Heat Sentinel  
- Reduces excessive temperatures  
in unoccupied room  
• GE-exclusive Superseal  
- Increased room comfort  
- Energy savings  
• Removes ꢀ5% more moisture from the  
air than standard GE packaged terminal  
air conditioners  
• Cool and dry air in less time than standard  
Zoneline models  
• Maintains comfort at slightly higher room  
temperatures  
- Helps reduce operating costs  
- Provides comfort without overcooling  
• Corrosion treatment is standard  
• Heat pipe is a separate sealed  
refrigerant system  
- No mechanical parts  
- No special maintenance required  
• Helps maintain lower relative humidity  
in rooms  
• Best suited for humid climates  
Includes all features of ꢀ900 series, plus:  
• Reverse cycle heating  
- Energy savings over electric  
resistance heat  
- Significantly lower operating costs  
• Heat pump operation down to ꢀ5°F  
outdoor temperature  
• Three-stage thermostat for quicker  
heat recovery  
• Optional factory-installed internal  
condensate removal (ICR)  
- Minimizes need for drain systems  
• Heat pump and resistance heat can  
operate together  
- Better room comfort  
- Helps reduce operating costs over  
all standard heat pump systems  
• Reverse cycle defrost  
- Extends heat pump operation  
- May help lower operating costs  
• Electric resistance heat lockout  
- Lowers operating costs by restricting  
electric heat operation when outdoor  
temperature is above ꢂꢃ°F.  
• Upfront filters  
- Ease of cleaning  
- Long-lasting nylon mesh  
• Central desk control compatibility  
• Remote thermostat capability  
• Smartfan  
- Fan cycle operation based on  
heat/cool selection  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ge.com  
Grille options  
Extruded aluminum:  
RAGꢃ7 (Shown)  
Stamped aluminum grille  
RAGꢃ0  
Exterior architectural louvers  
Durable polycarbonate:  
RAGꢃ1 (Warm Grey Beige)  
RAGꢃꢀ (Maple)  
RAGꢃꢁ (Bittersweet Chocolate)  
Retrofit kits (not shown)  
RAK901L - Wall Case Insulation for use  
with Heat Pumps  
RAK40 - Deflector Kit to adapt chassis for  
use with existing exterior architectural  
louvered grilles  
Requires power connection kit  
Grille  
Chassis  
Resistance heat  
Heat pump  
Deluxe  
Premium 5800 series  
Deluxe  
Deluxe  
Premium  
cooling with heat pump  
and resistance heat  
2900 Series  
Dry Air 25  
3900 Series 5800 Series  
Features  
Highly featured  
microcomputer controls  
Tactile touch pad controls with LED  
Universal heaters  
Solid-state thermostat  
ꢁ-position vent control  
Upfront filter (interchangeable)  
Automatic indoor frost control  
Sleep function  
Corrosion-treated chassis  
ꢀ-position discharge grille  
Fan motors  
“SmartFan” Fan cycle control  
Fan Only setting—ꢀ-speed  
Indoor fan speed  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Optional  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Optional  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Includes all features of ꢁ900 series, plus:  
• Two-fan-motor system with indoor  
cross flow blower  
- For quieter operation  
• Corrosion treatment is standard  
• Self-diagnostics  
• Connections for infrared/door  
switch sensors  
Standard  
Hi/Low  
Hi/Low  
Standard  
Hi/Low  
Hi/Low  
Standard  
Hi/Low  
Hi/Low  
Standard  
Hi/Low  
Hi/Low  
Cool & heat only settings  
Staged heating  
Hi/Low/Auto  
Hi/Low/Auto  
Hi/Low/Auto  
ꢁ-stage  
Hi/Low/Auto  
ꢁ-stage  
Freeze Sentinel™  
Heat Sentinel  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Temperature limiting  
Electronic 7-step Electronic 7-step Electronic 7-step Electronic 7-step  
Remote control compatibility  
Central desk control compatibility  
Service indicator  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Heat pump with resistance  
heat back-up  
Standard  
Standard  
Heat pump with supplemental  
resistance heat  
Standard  
Standard  
Standard  
Standard  
Standard  
Standard  
Automatic emergency heat  
Electric resistance heat lock-out  
Heat pump defrost system  
Internal condensate removal (ICR)*  
Quick heat recovery  
Standard  
Standard  
Reverse cycle Reverse cycle  
Optional  
Standard  
Optional  
Standard  
Standard  
Standard  
Self-diagnostics  
Auto power recovery  
Standard  
Standard  
Standard  
*Not for use in corrosive environments  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Deluxe models  
ꢀ900 series and Dry Air ꢀ5 series – heat/cool units  
ꢁ900 series – heat pump unit  
Highly featured microcomputer controls  
Central desk control  
compatible  
Ability to turn the unit  
“on” or "off" from a  
remote location.  
Two fan motors  
(not visible)  
Separate motors for  
indoor and outdoor fans  
to assure quiet operation.  
Reversible louver  
(not shown)  
May be reversed to  
provide an air discharge  
angle of ꢂ0 or 50 degrees  
off vertical with the simple  
removal of six screws.  
3-Position vent control  
(not shown)  
Opens vent. Provides up  
to 75 cfm of outdoor air.  
The closed position saves  
energy by recirculating  
conditioned room air.  
Reverse cycle defrost  
(not shown)  
Solid-state sensor  
monitors frost build-up  
on outdoor coil. When  
frost is detected, the  
Solid-state  
thermostat control  
Provides better room  
temperature control  
vs. electromechanical  
temperature control  
device.  
refrigerant flow is reversed  
to melt frost build-up.  
When completed, the  
refrigerant is reversed to  
the normal energy-saving  
heat pump operation for  
additional heat pump  
operating hours.  
Freeze Sentinel™  
Auto frost control  
Electronic  
Universal power cord  
Flexibility of heat  
applications. All  
Zonelines contain a  
bank of ꢁ heaters.  
Rotary compressor  
Fewer moving parts  
than reciprocating models  
for quiet, reliable operation  
and longer life.  
Provides automatic  
protection against  
freezing by switching  
the unit to heat should  
the temperature of an  
unoccupied room drop  
to ꢂ1°F.  
A special sensor monitors  
the roomside coil to  
temperature limiting  
Preset cooling and heating  
limits with 7 independent  
cooling and 7 heating  
limits—saves energy by  
preventing over-cooling  
or over-heating of rooms.  
prevent efficiency-robbing  
accumulation of frost  
during cooling operation.  
Easy-access filter  
(not shown)  
Twoupfrontinterchangeable  
filters are part of roomside  
cabinet for easy access  
and maintenance.  
Touch pad controls  
GE Dry Air 25  
(not shown)  
With electronic control  
temperature display. Gives  
the user finer control over  
the temperature.  
Heat Sentinel  
Innovative technology from  
Heat Pipe Technology, Inc  
enables the DryAir ꢀ5 to  
remove ꢀ5% more moisture  
from the air than standard  
GE packaged terminal air  
conditioners.  
“Smartfan”  
Provides automatic  
protection against  
overheating by switching  
on the unit to cool should  
the temperature of  
an unoccupied room  
reach 85°F.  
fan cycle selection  
Select fan cycle or fan  
continuous independently  
for heating and cooling.  
Remote control  
compatible  
Ability to be controlled  
by a wall-mounted  
thermostat with high  
or low fan speed.  
The Dry Air ꢀ5  
Special corrosion-protected units  
The Dry Air ꢀ5 features innovative technology from Heat Pipe  
Technology, Inc., an addition which enables this unit to remove ꢀ5%  
more moisture from the air than standard GE Zoneline® models. The  
Dry Air ꢀ5 system, Heat Pipe, is a hermetically sealed heat transfer  
surface that is saddlebagged around the indoor coil (evaporator) of  
the Zoneline. This coil arrangement will transfer heat from one coil to  
another without power consumption. This assembly uses R-ꢀꢀ as the  
refrigerant and is isolated from the regular Zoneline refrigerant circuit.  
To help extend the life of the Zoneline unit in seacoast areas, some  
Deluxe Zoneline units may be ordered with a special corrosion  
protection treatment on outdoor components and use stainless  
steel hardware. Zoneline units with optional corrosion protection  
have a ‘C’ in the 10th character of the model number.  
Internal condensate removal  
Available on the ꢁ900 and 5800 heat pumps, this feature drips the  
heat pump condensate over the warm indoor coil to help dissipate  
water from heat pump operation and associated defrost cycles. The  
installation of an internal or external drain system is recommended if  
no dripping of condensate to the outdoors is desired. ICR must not be  
installed in seacoast or corrosive applications.  
As warm humid air is pulled through the pre-cool section of the Heat  
Pipe, the heat removed from the air is absorbed by the refrigerant,  
causing the refrigerant to boil. As the pre-cooled air passes through  
the Zoneline evaporator, the air is further cooled (colder than it would  
be normally), removing ꢀ5% more moisture from the air than standard  
GE packaged terminal air conditioners.  
As the cold air passes through the reheat section of the Heat Pipe, the  
refrigerant condenses and the liquid flows back to the pre-cool section  
to be reheated again. The air discharged into the room by this process  
is much drier, creating a more comfortable room condition.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ge.com  
Premium models  
5800 series  
Highly featured microcomputer controls  
Cross-flow blower  
Quiet blower reduces  
annoying “Air rush” noise.  
Reversible louver  
(not shown)  
May be reversed to  
provide an air discharge  
angle of ꢂ0 or 50 degrees  
off vertical with the  
removal of six screws.  
3 position vent control  
(not shown)  
Opens vent. Provides up  
to 70 cfm of outdoor air.  
The closed position saves  
energy by recirculating  
conditioned room air.  
Two fan motors  
(not visible)  
Separate motors for  
indoor and outdoor fans  
to assure quiet operation.  
Touch pad controls  
With electronic control  
temperature display.  
Gives the user finer  
control over the  
Solid state  
thermostat control  
Provides better room  
temperature control  
vs. electromechanical  
temperature control  
device.  
temperature.  
Reverse cycle defrost  
(not shown)  
Solid state sensor  
Freeze Sentinel™  
Provides automatic  
protection against  
freezing by switching  
the unit to heat should  
monitors frost build-up  
on outdoor coil. When  
frost is detected, the  
refrigerant flow is reversed  
to melt frost build-up.  
When completed, the  
refrigerant is reversed  
to the normal energy  
saving heat pump  
Auto frost  
the temperature of an  
control monitor  
unoccupied room drop  
A special sensor monitors  
to ꢂ1°F.  
the roomside coil to  
prevent efficiency-robbing  
accumulation of frost  
during cooling cycle.  
Heat Sentinel  
Provides automatic  
protection against  
overheating by switching  
on the unit to cool should  
the temperature of  
an unoccupied room  
reach 85°F.  
operation for additional  
heat pump operating hours.  
Electronic  
Universal power cord  
Flexibility of heat  
applications. Each  
premium line Zoneline  
contains a bank of  
ꢁ heaters.  
Rotary compressor  
With fewer moving  
parts than reciprocating  
models for quiet,  
temperature limiting  
Preset cooling and heating  
limits with 7 independent  
cooling and 7 heating  
limits—saves energy by  
preventing over-cooling or  
over-heating of rooms.  
Central desk  
control compatible  
Ability to turn the unit  
“on” or “off” from a  
remote location.  
reliable operation.  
Room occupancy  
sensor compatible  
Ready for connection  
to room occupancy  
sensor system.  
Easy-access filter  
(not shown)  
Two upfront filters  
are part of roomside  
cabinet for easy access  
and maintenance.  
Remote control  
compatible  
Ability to be controlled  
by a wall-mounted  
thermostat with high  
or low fan speed.  
Microcomputer controls  
Electronic components  
for fast response and  
accuracy.  
“Smartfan”  
fan cycle selection  
Select fan cycle or fan  
continuous independently  
for heating and cooling.  
Weather-protected  
electrical components  
On inside of barrier.  
Wall sleeve dimensions  
Heavy-gauge galvanized  
steel with a baked enamel  
finish for outstanding  
Electrical connection  
A
ꢀꢁ0/ꢀ08 volt units may be plugged into  
a receptacle. ꢀꢃ5 volt units are provided  
with a junction box and require direct  
connection. (NEC Requires ꢀꢃ5V Direct  
Connection.) See Architects and Engineers  
Design Data Manual for electrical  
C
protection and appearance.  
RAB71A wall sleeve  
Heavy-gauge galvanized steel, with insulation.  
A-ꢂꢀ", B-1ꢁ ꢁ/ꢂ", C-1ꢃ"  
connection information including use of  
sub-base for direct-connected units. Installation  
B
must comply with local electrical codes and regulations.  
RAB77A4 wall sleeve (shown above)  
Molded SMC fiberglass-reinforced polyester compound.  
A-ꢂꢀ 1/8", B-1ꢁ 7/8", C-1ꢃ 1/ꢂ"  
Ducted applications  
ꢀ900 and ꢁ900 series can be used with ductwork to heat or cool more  
than one room. RAKꢃ05ꢀ Duct Adapter is applied to top of case over air  
discharge. RAKꢃ01 Duct Extension is applied to right or left of adapter.  
Locally fabricated ductwork may be added to extend to maximum  
recommended distance of 15 feet.  
Wall opening dimensions  
Add 1/ꢂ" to A and C dimensions for all cutout sizes.  
RAB71 1ꢃ 1/ꢂ" min. H. x ꢂꢀ 1/ꢂ" min. W.  
RAB71 available in 1ꢃ", ꢀꢂ", ꢀ8" and ꢁ1" depths.  
RAB77Aꢂ 1ꢃ 1/ꢀ" min. H. x ꢂꢀ ꢁ/8" min. W.  
For additional information on ducted applications, including special  
adapters for replacement units, refer to Architects and Engineers Design  
Data Manual.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Receptacles/Sub-bases  
Tandem  
Perpendicular  
Large tandem  
265V 15 Amp  
265V 20 Amp  
265V 30 Amp  
ꢀꢁ0/ꢀ08V 15 Amp  
NEMAꢃ-15R  
ꢀꢁ0/ꢀ08V ꢀ0 Amp  
NEMAꢃ-ꢀ0R  
ꢀꢁ0/ꢀ08V ꢁ0 Amp  
NEMAꢃ-ꢁ0R  
NEMA7-15R  
NEMA7-ꢀ0R;  
NEMA7-ꢁ0R;  
receptacle used  
On ꢀꢃ5V sub-base  
GE07ꢁ  
receptacle used  
On ꢀꢃ5V sub-base  
GE07ꢀ0-ꢁ  
Sub-bases  
RAK204U  
N/A  
RAK204D15P  
RAK204D20P  
RAK204D30P  
RAK204E15  
RAK204E20  
RAK204E30  
ꢀꢃ5  
Voltage  
Amps  
ꢀꢁ0/ꢀ08  
15  
ꢀꢁ0/ꢀ08  
ꢀ0  
ꢀꢁ0/ꢀ08  
ꢁ0  
ꢀꢃ5  
15  
ꢀꢃ5  
ꢀ0  
N/A  
ꢁ0  
Receptacle  
N/A  
NEMAꢃ-ꢀ0R  
NEMAꢃ-ꢀ0R  
NEMAꢃ-ꢁ0R  
NEMA7-15R  
NEMA7-ꢀ0R  
NEMA7-ꢁ0R  
ꢀꢁ0/ꢀ08 Volt sub-bases include appropriate power cord kit.  
ꢀꢃ5 Volt units are to be direct connected. Cordset through enclosed chaseway into interior sub-base receptacle meets the NEC requirements.  
Power connection kits are required on all Zoneline® chassis (see chart below).  
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the  
building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent  
connection kit would be used. ꢀꢃ5 volt cord set units must be installed in compliance with National Electrical Code®.  
Power connection kits  
Required on all models.  
See specification sheet  
for heater KW and branch  
circuit ampacity.  
RAKꢁ15ꢁ/ꢁꢀ0ꢁ  
ꢀꢁ0/ꢀ08 volt line cord  
connection kit  
RAKꢂ157/ꢂꢀ07/ꢂꢁ07  
ꢀꢁ0/ꢀ08 volt universal  
power supply kit  
RAK5157/5ꢀ07/5ꢁ07  
ꢀꢃ5 volt universal power  
supply kit  
230/208 volt  
Line cord connected units  
265 volt Permanent connected units* (Cord set)  
LCDI Power Connection Kit  
RAK3153  
ꢀ.55/ꢀ.09  
ꢀ,550/ꢀ,090  
8,ꢃ00/7,100  
11.ꢃ/10.ꢃ  
15  
RAK3203  
ꢁ.ꢂ5/ꢀ.8ꢀ  
ꢁ,ꢂ50/ꢀ,8ꢀ0  
11,700/9,ꢃ00  
15.ꢃ/1ꢂ.ꢀ  
ꢀ0  
RAK3303  
RAK5172  
ꢀ.55  
RAK5202  
ꢁ.ꢂ5  
RAK5302  
5.0  
Heater KW  
Watts  
5.00/ꢂ.09  
5,000/ꢂ,090  
17,000/1ꢁ,900  
ꢀꢀ.ꢂ/ꢀ0.ꢂ  
ꢁ0  
ꢀ,550  
8,ꢃ00  
10.ꢁ  
ꢁ,ꢂ50  
11,700  
1ꢁ.8  
5,000  
17,000  
19.ꢃ  
BTUH  
Amps  
Min. circuit amps  
15  
ꢀ0  
ꢁ0  
Recommended  
protective  
device  
15 amp  
time delay  
fuse or breaker  
ꢀ0 amp  
time delay  
fuse or breaker  
ꢁ0 amp  
time delay  
fuse or breaker  
15 amp  
time delay fuse  
ꢀ0 amp  
time delay fuse  
ꢁ0 amp  
time delay fuse  
*To be used with sub-base  
230/208 volt  
Direct connection kit**  
265 volt Direct connection kit**  
RAK4157  
ꢀ.55/ꢀ.09  
ꢀ,550/ꢀ,090  
8,ꢃ00/7,100  
11.ꢃ/10.ꢃ  
15  
RAK4207  
ꢁ.ꢂ5/ꢀ.8ꢀ  
ꢁ,ꢂ50/ꢀ,8ꢀ0  
11,700/9,ꢃ00  
15.ꢃ/1ꢂ.ꢀ  
ꢀ0  
RAK4307  
5.00/ꢂ.09  
5,000/ꢂ,090  
17,000/1ꢁ,900  
ꢀꢀ.ꢂ/ꢀ0.ꢂ  
ꢁ0  
RAK5157  
ꢀ.55  
RAK5207  
ꢁ.ꢂ5  
RAK5307  
5.0  
Heater KW  
Watts  
ꢀ,550  
8,ꢃ00  
10.ꢁ  
ꢁ,ꢂ50  
11,700  
1ꢁ.8  
5,000  
17,000  
19.ꢃ  
BTUH  
Amps  
Min. circuit amps  
15  
ꢀ0  
ꢁ0  
Recommended  
protective  
device  
15 amp  
time delay  
fuse or breaker  
ꢀ0 amp  
time delay  
fuse or breaker  
ꢁ0 amp  
time delay  
fuse or breaker  
15 amp  
time delay fuse  
ꢀ0 amp  
time delay fuse  
ꢁ0 amp  
time delay fuse  
**To be used with sub-base or connection to building wiring  
**To be used with sub-base or connection to building wiring  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ge.com  
Preliminary specifications  
Deluxe series – cooling & electric heat  
2900 series units  
Dry Air 25  
Dry Air 25  
AZ29E09DAP  
230/208V Models  
Capacity  
AZ29E07D  
AZ29E09D  
AZ29E12D  
AZ29E15D  
AZ29E07DAP  
AZ29E12DAP  
Cooling BTUH  
7,100/ꢃ,900  
1ꢀ.7/1ꢀ.7  
1.7  
9,ꢁ00/8,900  
1ꢀ.0/1ꢀ.0  
ꢀ.7  
11,700/11,500  
11.5/11.5  
ꢁ.ꢃ  
1ꢂ,ꢃ00/1ꢂ,ꢁ00  
10.ꢀ/10.ꢀ  
ꢂ.ꢃ  
ꢃ,800/ꢃ,ꢃ00  
1ꢀ.1/1ꢀ.1  
ꢀ.ꢁ  
8,800/8,500  
11.5/11.5  
ꢁ.ꢂ  
11,ꢀ00/11,000  
11.0/11.0  
ꢂ.5  
EER (BTU/Watt)  
Dehumidification Pts/Hr  
Features  
CFM, indoor fan high  
CFM, indoor fan low  
Vent CFM (full open/partial open)  
Power/Ratings  
Power factor  
Sensible heat ratio @ ꢀꢁ0 volts  
Watts  
Amperes, F.L.  
ꢀ50  
ꢀ15  
50/ꢂ0  
ꢀ70  
ꢀꢁ5  
70/ꢂ5  
ꢀ90  
ꢀꢂ0  
75/ꢂ5  
ꢁ10  
ꢀ80  
75/ꢂ5  
ꢀ10  
175  
50/ꢂ0  
ꢀꢁ0  
ꢀ00  
70/ꢂ5  
ꢀꢂ0  
ꢀ10  
75/ꢂ5  
8ꢃ/87  
75%  
5ꢃ0/5ꢂ5  
ꢀ.8/ꢁ.0  
8ꢃ/87  
ꢃ8%  
775/7ꢂ5  
ꢁ.8/ꢂ.1  
91/91  
ꢃ7%  
1,0ꢀ0/1,000  
ꢂ.9/5.ꢁ  
89/90  
ꢃ7%  
1ꢂꢁ0/1ꢂ05  
7.0/7.5  
87/87  
ꢃꢃ%  
5ꢃ0/5ꢂ5  
ꢀ.8/ꢁ.0  
8ꢃ/8ꢃ  
58%  
7ꢃ5/7ꢂ0  
ꢁ.8/ꢂ.1  
91/91  
57%  
1,0ꢀ0/1,000  
ꢂ.9/5.ꢁ  
Amperes, L.R.  
19.0  
ꢀ1.0  
ꢁ1.0  
ꢁ8.0  
19.0  
ꢀ1.0  
ꢁ1.0  
Weight (Net/Ship)  
100/115  
101/11ꢃ  
105/1ꢀ0  
115/1ꢁ0  
100/115  
101/11ꢃ  
105/1ꢀ0  
Sound Transmission Class (STC)  
ꢀ9  
ꢀ9  
ꢀ9  
ꢀ9  
ꢀ9  
ꢀ9  
ꢀ9  
265V Models  
AZ29E07E  
AZ29E09E  
AZ29E12E  
AZ29E15E  
AZ29E07EAP  
AZ29E09EAP  
AZ29E12EAP  
Capacity  
Cooling BTUH  
7,100  
1ꢀ.7  
1.7  
9,000  
1ꢀ.0  
ꢀ.7  
11,700  
11.5  
ꢁ.ꢃ  
1ꢂ,ꢃ00  
10.ꢀ  
ꢂ.ꢃ  
ꢃ,800  
1ꢀ.1  
ꢀ.ꢁ  
8,ꢃ00  
11.5  
ꢁ.ꢂ  
11,ꢀ00  
11.0  
ꢂ.ꢂ  
EER (BTU/Watt)  
Dehumidification Pts/Hr  
Features  
CFM, indoor fan high  
CFM, indoor fan low  
Vent CFM (full open/partial open)  
Power/Ratings  
Power factor  
Sensible heat ratio @ ꢀꢃ5 volts  
Watts  
Amperes, F.L.  
ꢀ50  
ꢀ15  
50/ꢂ0  
ꢀ70  
ꢀꢁ5  
70/ꢂ5  
ꢀ90  
ꢀꢂ0  
75/ꢂ5  
ꢁ10  
ꢀ80  
75/ꢂ5  
ꢀ10  
175  
50/ꢂ0  
ꢀꢁ5  
ꢀ00  
70/ꢂ5  
ꢀꢂ0  
ꢀ10  
75/ꢂ5  
87  
75%  
5ꢃ0  
8ꢃ  
ꢃ8%  
750  
87  
ꢃ7%  
1,0ꢀ0  
ꢂ.ꢂ  
90  
ꢃ7%  
1ꢂꢁ5  
ꢃ.0  
88  
ꢃꢃ%  
5ꢃ0  
8ꢃ  
58%  
750  
87  
57%  
1,0ꢀ0  
ꢂ.ꢂ  
ꢀ.ꢂ  
ꢁ.ꢁ  
ꢀ.ꢂ  
ꢁ.ꢁ  
Amperes, L.R.  
Weight (Net/Ship)  
Sound Transmission Class (STC)  
1ꢃ.0  
100/115  
ꢀ9  
18.0  
100/115  
ꢀ9  
ꢀꢂ.0  
105/1ꢀ0  
ꢀ9  
ꢁ1.0  
115/1ꢁ0  
ꢀ9  
1ꢃ.0  
100/115  
ꢀ9  
18.0  
101/11ꢃ  
ꢀ9  
ꢀꢂ.0  
105/1ꢀ0  
ꢀ9  
Deluxe series – heat pump units**  
3900 series units  
Premium series – heat pump units  
5800 series units  
230/208V Models  
Capacity  
AZ39H07D  
AZ39H09D  
AZ39H12D  
AZ39H15D  
AZ58H07D  
AZ58H09D  
AZ58H12D  
AZ58H15D  
Cooling BTUH  
7,100/ꢃ,900  
1ꢀ.7/1ꢀ.7  
1.7  
9,ꢂ00/9,150  
1ꢀ.0/1ꢀ.0  
ꢀ.7  
11,850/11,500  
11.5/11.5  
ꢁ.ꢃ  
1ꢂ,750/1ꢂ,ꢁ50  
10.0/10.0  
ꢂ.5  
7,ꢁ00/7,000  
1ꢁ.0/1ꢁ.0  
ꢀ.1  
9,ꢁ00/9,050  
1ꢀ.0/1ꢀ.0  
ꢁ.0  
11,800/11,ꢃ00  
11.7/11.7  
ꢂ.0  
1ꢂ,700/1ꢂ,ꢂ00  
10.ꢁ/10.ꢁ  
ꢂ.8  
EER (BTU/Watt)  
Dehumidification Pts/Hr  
Features  
CFM, indoor fan high  
CFM, indoor fan low  
Vent CFM (full open/partial open)  
Power/Ratings  
Power factor  
Sensible heat ratio @ ꢀꢁ0 volts  
Watts  
Amperes, F.L.  
ꢀ50  
ꢀ15  
50/ꢂ0  
ꢀ70  
ꢀꢁ5  
70/ꢂ5  
ꢁ00  
ꢀꢃ0  
75/ꢂ5  
ꢁ10  
ꢀꢃ0  
75/ꢂ5  
ꢀ50  
ꢀꢁ0  
ꢂ0/ꢁ5  
ꢀꢃ5  
ꢀꢂ5  
ꢃ5/ꢃ0  
ꢁ50  
ꢁꢁ0  
70/ꢃ5  
ꢁꢃ5  
ꢁꢂ5  
70/ꢃ5  
87  
75%  
5ꢃ0/5ꢂ5  
ꢀ.8/ꢁ.0  
19.0  
88  
ꢃ8%  
785/7ꢃ5  
ꢁ.8/ꢂ.1  
ꢀ1.0  
91  
ꢃ7%  
10ꢁ0/1000  
ꢂ.9/5.ꢁ  
ꢁ1.0  
9ꢀ  
ꢃ7%  
1ꢂ80/1ꢂꢂ0  
7.0/7.5  
95  
75%  
5ꢃ0/5ꢂ0  
ꢀ.7/ꢀ.8  
19.0  
9ꢃ  
ꢃ7%  
7ꢃ0/7ꢁ5  
ꢁ.ꢃ/ꢁ.8  
ꢀ1.0  
9ꢂ  
ꢃ8%  
1010/990  
ꢂ.ꢃ/5.0  
ꢁꢁ.0  
95  
ꢃ5%  
1ꢂꢀ5/1ꢂ00  
ꢃ.5/7.0  
Amperes, L.R.  
ꢁ8.0  
ꢁ8.0  
Reverse cycle heat BTUH  
COP  
Watts  
ꢃ,ꢂ00/ꢃ,ꢀ00  
ꢁ.ꢃ/ꢁ.ꢃ  
5ꢀ0/505  
ꢀ.ꢂ/ꢀ.ꢃ  
10ꢀ/117  
ꢀ9  
8,500/8,ꢀ50  
ꢁ.ꢃ/ꢁ.ꢃ  
ꢃ95/ꢃ75  
ꢁ.ꢀ/ꢁ.5  
105/1ꢀ0  
ꢀ9  
10,900/10,700  
ꢁ.ꢂ/ꢁ.ꢂ  
950/9ꢀ5  
ꢂ.ꢁ/ꢂ.7  
11ꢁ/1ꢀ8  
ꢀ9  
1ꢁ,750/1ꢁ,ꢂ00  
ꢁ.ꢀ/ꢁ.ꢀ  
1,ꢀ75/1,ꢀꢂ5  
5.8/ꢃ.ꢁ  
1ꢀꢁ/1ꢁ8  
ꢀ9  
ꢃ,ꢂ00/ꢃ,ꢀ00  
ꢁ.7/ꢁ.7  
505/ꢂ90  
ꢀ.ꢂ/ꢀ.5  
108/1ꢀꢀ  
ꢀ9  
8,ꢂ00/8,ꢀ00  
ꢁ.ꢃ/ꢁ.ꢃ  
ꢃ85/ꢃ70  
ꢁ.ꢀ/ꢁ.ꢂ  
11ꢁ/1ꢀ8  
ꢀ9  
10,900/10,700  
ꢁ.ꢂ/ꢁ.ꢂ  
9ꢂ0/9ꢀ0  
ꢂ.ꢁ/ꢂ.7  
118/1ꢁꢁ  
ꢀ9  
1ꢁ,800/1ꢁ,800  
ꢁ.ꢀ/ꢁ.ꢀ  
1,ꢀꢃ5/1,ꢀꢁ5  
5.7/ꢃ.ꢀ  
1ꢀ7/1ꢂꢀ  
ꢀ9  
Amps  
Weight (Net/Ship)  
Sound Transmission Class (STC)  
265V Models  
AZ39H07E  
AZ39H09E  
AZ39H12E  
AZ39H15E  
AZ58H07E  
AZ58H09E  
AZ58H12E  
AZ58H15E  
Capacity  
Cooling BTUH  
EER (BTU/Watt)  
Dehumidification Pts/Hr  
7,100  
1ꢀ.7  
1.7  
9,ꢂ00  
1ꢀ.0  
ꢀ.7  
11,700  
11.5  
ꢁ.ꢃ  
1ꢂ,750  
10.0  
ꢂ.5  
7,ꢁ00  
1ꢁ.0  
ꢀ.1  
9,ꢁ00  
1ꢀ.0  
ꢁ.0  
11,800  
11.7  
ꢂ.0  
1ꢂ,700  
10.ꢁ  
ꢂ.8  
Features  
CFM, indoor fan high  
CFM, indoor fan low  
Vent CFM (full open/partial open)  
Power/Ratings  
ꢀ50  
ꢀ15  
50/ꢂ0  
ꢀ70  
ꢀꢁ5  
70/ꢂ5  
ꢁ00  
ꢀꢃ0  
75/ꢂ5  
ꢁ10  
ꢀꢃ0  
75/ꢂ5  
ꢀ50  
ꢀꢀ0  
ꢂ0/ꢁ5  
ꢀꢃ5  
ꢀ70  
ꢃ5/ꢃ0  
ꢁ50  
ꢁ10  
70/ꢃ5  
ꢁꢃ5  
ꢁꢁ0  
70/ꢃ5  
Power factor  
Sensible heat ratio @ ꢀꢃ5 volts  
Watts  
88  
75%  
5ꢃ0  
88  
ꢃ8%  
785  
87  
ꢃ7%  
10ꢀ0  
ꢂ.ꢂ  
9ꢀ  
ꢃ7%  
1ꢂ80  
ꢃ.0  
95  
75%  
5ꢃ0  
9ꢃ  
ꢃ7%  
7ꢃ0  
9ꢂ  
ꢃ8%  
1010  
ꢂ.ꢂ  
95  
ꢃ5%  
1ꢂꢀ5  
5.8  
Amperes, F.L.  
ꢀ.ꢂ  
ꢁ.ꢁ  
ꢀ.ꢀ  
ꢁ.ꢀ  
Amperes, L.R.  
Reverse cycle heat BTUH  
COP  
1ꢃ.0  
ꢃ,ꢂ00  
ꢁ.ꢃ  
18.0  
8,550  
ꢁ.ꢃ  
ꢀꢂ.0  
10,900  
ꢁ.ꢂ  
ꢁ1.0  
1ꢁ,750  
ꢁ.ꢀ  
1ꢃ.0  
ꢃ,ꢂ00  
ꢁ.7  
18.0  
8,ꢂ00  
ꢁ.ꢃ  
ꢀꢂ.0  
10,900  
ꢁ.ꢂ  
ꢁ1.0  
1ꢁ,800  
ꢁ.ꢀ  
Watts  
Amps  
5ꢀ0  
ꢀ.ꢀ  
700  
ꢀ.8  
9ꢂ0  
ꢁ.9  
1,ꢀ75  
5.0  
505  
ꢀ.ꢀ  
ꢃ85  
ꢀ.7  
9ꢂ0  
ꢁ.9  
1,ꢀꢃ5  
5.0  
Weight (Net/Ship)*  
Sound Transmission Class (STC)  
**ICR adds ꢁ pounds to unit weight  
**Corrosion model BTUH and watts may vary.  
10ꢀ/117  
ꢀ9  
109/1ꢀꢂ  
ꢀ9  
11ꢁ/1ꢀ8  
ꢀ9  
1ꢀꢁ/1ꢁ8  
ꢀ9  
108/1ꢀꢀ  
ꢀ9  
11ꢁ/1ꢀ8  
ꢀ9  
118/1ꢁꢁ  
ꢀ9  
1ꢀ7/1ꢂꢀ  
ꢀ9  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Zoneline® chassis nomenclature  
Zoneline warranty*  
The Zoneline® chassis is identified by a model number defining the type  
of unit, cooling capacity, electrical information and optional features  
included on the unit. When specifying or ordering the Zoneline chassis,  
use of this nomenclature will assure receiving the correct unit.  
What is covered  
Limited one-year warranty  
For one year from the date of the original purchase, GE will repair or  
replace any part of the air conditioner which fails due to a defect in  
materials or workmanship. During this limited one-year warranty, GE  
will provide, free of charge, all labor and related service costs to repair  
or replace the defective part.  
A
Z
5
8
H
1
2
D
A
D
Chassis series  
Nominal cooling capacity Universal  
Zoneline  
packaged  
terminal  
chassis  
ꢀ9=deluxe line cool/  
electric heat  
ꢁ9=deluxe line heat pump 1ꢀ=1ꢀ,000 BTUH cooling  
58=premium line  
heat pump  
07=7,000 BTUH cooling  
09=9,000 BTUH cooling  
power connection  
Limited five-year warranty  
Special Features  
B=base unit  
C=corrosion treated  
D=internal  
For five years from the date of the original purchase, GE will repair  
or replace the Sealed Refrigerating System if any part of the Sealed  
Refrigerating System (the compressor, condenser, evaporator, and  
all connecting tubing) should fail due to a defect in materials or  
workmanship. During this limited five-year warranty, GE will provide, free  
of charge, all labor and related service costs to repair or replace  
the defective part.  
15=15,000 BTUH cooling  
Voltage/Phase/  
Frequency  
D=ꢀꢁ0/ꢀ08 Volt, single  
phase, ꢃ0 Hz  
Unit type  
E=cooling with electric  
resistance heat  
H=heat pump with electric  
resistance heat  
condensate  
removal (ICR)  
system (heat  
pump models  
only) (not for  
coastal areas)  
P=Dry Air ꢀ5  
E=ꢀꢃ5 Volt, single phase,  
ꢃ0 Hz  
Limited second through fifth year parts warranty  
From the second through the fifth year from the date of the original  
purchase, GE will replace the Fan Motors, Switches, Thermostat, Heater,  
Heater Protectors, Compressor Overload, Solenoids, Circuit Boards,  
Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump,  
Capacitors, Varistors and Indoor Blower Bearing, if any of these parts  
should fail due to a defect in materials or workmanship. During this  
additional four-year limited warranty, you will be responsible for any  
labor and related service costs.  
*See written warranty for details  
Listed by  
Underwriters  
Laboratories.  
R
P
R
I
For detailed information on operating specifications, installation data and accessories,  
see the GE Zoneline Architects and Engineers Design Data Manual.  
A century of quality and innovation  
For more than a century, GE has been committed to producing innovative products  
that change the way people live. The result of thorough research and rigorous testing,  
GE appliances are designed for years of dependable performance.  
Today, the GE tradition of quality and innovation continues.  
For GE appliance service in the US, call  
1-800-GE CARES. In Canada call 1-888-ꢀ09-0999.  
GE Consumer & Industrial  
Appliances  
GE has a policy of continuous improvement of  
its products and reserves the right to change  
materials and specifications without notice.  
General Electric Company  
Louisville, KY 40225  
ge.com  
© ꢀ008 GE Company  
Pub. No. ꢀ0-S097  
PC5190ꢀ  
zoneline.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Compaq Network Card AA RNG2A TE User Manual
Cooper Lighting Indoor Furnishings CFE 4 User Manual
Cub Cadet Lawn Mower SC2400 User Manual
Cuisinart Blender SPB 10 Series User Manual
Danby Dehumidifier DDR3011 User Manual
Dimension One Spas Hot Tub AquaPro 19 User Manual
EverFocus Security Camera EHD363 User Manual
Fisher Price Car Seat J5933 H9499 L1907 M4794 User Manual
Frigidaire Washer FRFW3700L W User Manual
Fusion Portable Speaker MS 0S420 User Manual