Part Number EV9100-51
INSTALLATION AND OPERATING INSTRUCTIONS
CB20-124E FILTRATION SYSTEM
SYSTEM INSTALLATIONS
NOTE: Always use a good grade of pipe sealant or teflon tape on
connections.
GENERAL PRECAUTIONS
Maximum Pressure: 20-100 psi non-stock (1.4-6.9 bar)
Temperature: 35-100°F (2-38°C)
®
1. Reduce product weight by removing bowl from header assembly
Install On Cold Water Lines Only
before mounting unit.
Installation By a Certified Installer Is Recommended
2. Determine installation location using head assembly.
3. Assemble By-Pass, if using and install to head.
4. Install system brackets. Mount system.
Housing Inlet & Outlet: 3/4"
Rated service flow: 5 gpm (19 Lpm)
Do not install where unit is exposed to direct sunlight.
5. Turn off water and power supply to all beverage equipment and
Allow a minimum of 4" clearance under the filter to facilitate cartridge
change. Make certain that the installation complies with all state and
local laws and regulations.
icemaker.
6. Connect cartridge system to feed water supply, beverage sys-
tems, and icemaker.
WARNING: This filter must be protected from freezing. Failure to do
so may result in cracking of the filter and water leakage.
7. Sanitize filter bowls using dilute (0.5%) household bleach solution,
Diversol™ or equivalent.
8. Handle cartridges by plastic wrap to minimize contact.
CB20-124E FILTRATION SYSTEM
9. Lubricate “O-rings” with silicone lubricant and secure to system
head. Hand tighten.
10. Cartridge Change and Flush Procedure:
Insert the fresh cartridge into the clean bowl and screw the bowl
into the head, hand tight only. Turn on water and flush cartridge
for 15 minutes.
1
7 ⁄4
"
3/4" Outlet
Connection
to Equipment
3/4" Inlet
Connection
from Supply
11. Close flushing valve and inspect for leaks.
12. Turn power to beverage equipment and icemaker back on.
13. Clean up and give final inspection.
14. Obtain Manager sign-off on work confirmation form.
3
25 ⁄4
"
REPLACEMENT CARTRIDGE
CC1E Carbon Filter
Replace cartridge when capacity is reached or pressure drops below
15 psi, but at least every 6 months.
1. Turn power off to beverage equipment.
2. Turn water off to CB20-124E system.
3. Unscrew bowl assembly from header, remove exhausted cartridge
and discard. CAUTION: Bowl is heavy with water.
4. Unwrap new cartridge and place in bowl. Screw bowl into appro-
Mounting Depth: 8.5"
Operating Weight: 30 lbs.
Allow a minimum of 4" clearance under the
filter to facilitate cartridge change.
priate head on system.
5. Turn on water and flush cartridge for 15 minutes.
For assistance or to find the nearest dealer for replacement parts call:
Everpure Customer Service 1-800-323-7873
Everpure Technical Service 1-800-942-1153
System Tested and Certified by NSF International against NSF/ANSI
Standard 42 for the aesthetic reduction of Chlorine Taste and Odor and
Chloramine Reduction.