| FEATURES   Heavy-duty 14 gauge steel heat exchanger with a   durable ceramic fiber combustion chamber   Ducane Oil Furnace   Easy access large diameter clean out ports in heat   exchanger   RLBF/R80C   Foil-faced high density fiberglass insulation in cabinet   reduces heat loss and sound   Cabinet has pre-painted steel for maximum durability   Internal filter included   Direct drive models have slide-out blower design   blower for easy cleaning and service   4-speed PSC direct drive blower assemblies are   dynamically balanced with resilient motor mounts for   smooth and quiet operation   Belt drive models have permanently lubricated split   phase blower motor, adjustable pulley and sheave   High quality Beckett Flame Retention burner for   efficient combustion   High efficiency air flow system to provide consistent   operation through all operating conditions   Honeywell 7184B primary control with 15 second pre   purge, interrupted ignition, limited reset, and LED   diagnostics   Solid state ignition with 20KV output voltage   PSC burner motor with low amp draw and ball   bearings for long life   40 VA transformer (Direct drive only)   Transformer and cooling fan relay are factory wired   for easy add-on cooling installation (Direct drive only)   Limited life-time warranty on heat exchanger and five   year limited warranty on all parts   C Download from Www.Somanuals.com. All Manuals Search And Download.   Blower Performance - Direct Drive   Motor   Size   (hp)   Temp.   Rise   (oF)   CFM @ ext. static pressure - in. W.C.   Blower   Size   Blower   Speed   Model   .20   .30   .40   .50   .60   .70   .80   .90   High   1,400   1,350   1,130   917   1,307   1,103   903   1,250   1,075   867   1,187   1,027   843   1,105   967   798   1,027   895   728   914   765   632   518   998   936   832   650   Med High 1,136   RLBF80C57/72D12   1/3   1/2   10 x 8 45 - 75   10 x 9 45 - 75   Med   Low   High   930   783   1,760   773   753   732   706   663   604   1,670   1,415   1345   1,150   2,080   1,810   1,600   1,599   1,459   1,300   1,130   2,010   1,744   1,580   1,550   1,394   1,259   1,105   1,969   1,670   1,490   1,410   1,307   1,188   1,033   1,850   1,580   1,430   1,315   1,190   1,075   955   1,735   1,510   1,370   1,170   1,080   975   Med High 1,603   RLBF80C84/95D16   Med   Low   High   1,373   1,162   2,160   853   1,627   1,403   1,310   1,510   1,305   1,236   Med High 1,850   RLBF80C112/125D20 3/4 12 x 10 45 - 75   Med   Low   High   1,650   1,480* 1,470* 1,445* 1,380* 1,330* 1,276* 1,197* 1,090*   1,400   1,350   1,130   917   1,307   1,103   903   1,250   1,075   867   1,187   1,027   843   1,105   967   798   1,027   895   728   914   765   632   518   998   936   832   650   Med High 1,136   RLBR80C57/72D12   RLBR80C84/95D16   1/3   1/2   10 x 8 45 - 75   10 x 9 45 - 75   Med   Low   High   930   783   1,760   773   753   732   706   663   604   1,670   1,415   1345   1,150   2,124   1,755   1,525   1,599   1,459   1,300   1,130   2,029   1,704   1,550   1,394   1,259   1,105   1,980   1,625   1,410   1,307   1,188   1,033   1,835   1,549   1,369   1,315   1,190   1,075   955   1,730   1,454   1,279   1,170   1,080   975   Med High 1,603   Med   Low   High   1,373   1,162   2,221   853   1,575   1,350   1,206   1,514   1,250   1,114   Med High 1,815   RLBR80C112/125D20 3/4 12 x 10 45 - 75   RLBR80C140/168D20 3/4 12 x 10 45 - 75   Med   Low   High   1,564   1,501 1,435   1,360* 1,355* 1,310* 1,260* 1,205* 1,150* 1,087* 998*   2,245   2,138   1,780   1,590   2,034   1,729   1,540   1,985   1,670   1,490   1,833   1,609   1,435   1,750   1,523   1,335   1,690   1,415   1,269   1,550   1,318   1,188   Med High 1,835   Med   1,620   Low   1,460* 1,435* 1,400* 1,320* 1,280* 1,200* 1,132* 1,050*   *Not recommended for heating. Temperature rise may be outside acceptable range.   Download from Www.Somanuals.com. All Manuals Search And Download.   Blower Performance - Belt Drive   CFM @ .20   ext. static   pressure - in.   W.C.   Motor   Size   Motor   Pulley   (in.)   Motor   Pulley   Adjustment   Blower   Pulley   (in.)   Belt   Size   (in.)   Temp.   Rise   (oF)   Blower   Size   Model   (hp)   RLBF80C57B08   1/6   1/4   10 x 8   10 x 8   3 1/4   4 1 Turn   Closed   7 7 40   41   45 - 75   45 - 751   55 - 852   50 - 801   55 - 852   50 - 80   50 - 801   55 - 852   55 - 851   60 - 902   65 - 95   980   RLBF80C84/95B10   1300   RLBF80C112/125B16   RLBR80C57B08   3/4   1/6   1/4   12 x 9   10 x 8   10 x 8   4 3 1/4   4 Closed   1 Turn   Closed   7 7 7 42   40   41   1750   860   RLBR80C84/95B10   1220   RLBR80C112/125B16   3/4   3/4   12 x 9   4 6 Closed   Closed   7 42   42   1700   2660   RLBR80C196B24   Low Fire Nozzle   High Fire Nozzle   12 x 12   3 1/2   1 2 Alternate Motors for Cooling Combinations - Belt Drive   CFM @ ext. static pressure - in.   W.C.   Nominal Motor Blower Motor   Motor   Pulley   Adjustment   Blower Belt   Pulley Size   Model   Cooling   Capacity (in.)   Size   Size   (in.)   Pulley   (in.)   (in.)   (in.)   41   40   38   41   40   38   42   .20   .30   .40   .50   RLBF80C57B08   2.0 - 2.5   RLBF80C84/95B10 2.0 - 3.5   RLBF80C112/125B16 4.0 - 5.0   2.0 - 2.5   RLBR80C84/95B10 2.0 - 3.5   RLBR80C112/125B16 4.0 - 5.0   1/4   1/2   3/4   1/4   1/2   3/4   3/4   10 x 8   10 x 8   12 x 9   10 x 8   10 x 8   12 x 9   12 x 12   7 6 5 7 6 5 6 Closed   Closed   Closed   Closed   Closed   Closed   Closed   4 4 1,340* 1,320*   1,180   1,560   1,930   1,095   1,480   1,910   2,450   1,080   1,430   1,880   1,000   1,400   1,860   2,350   1,770   2,050   1,260   1,600   2,020   2,660   1,680   2,000   1,185   1,540   1,980   2,575   3 1/4   4 RLBR80C57B08   4 3 1/4   3 1/2   RLBR80C196B24   5.0 - 6.0   *Not recommended for heating. Temperature rise may be outside acceptable range.   Note: Field converted with different size motor for cooling applications.   Download from Www.Somanuals.com. All Manuals Search And Download.   Accessories   Description   Used with   All models   Kit Number   ABRSH380-3   ASVNT522   Clean Out Kit   Tjernlund Side Wall Vent Kit1   Field Controls Side Wall Vent Kit2   Evaporator Coil Cabinet   Evaporator Coil Cabinet   Evaporator Coil Cabinet   Combustion Air Kit   All models   All models   ASVNT523   RLBF-R8084/95 to 15 1/2" - 17" wide coil   RLBF-R8084/95 & LBF-R112/125 to 21" wide coil   RLBF-R112/125 to 21"-23" wide coil   All models   ACOILKDCC19   ACOILKDCC22   ACOILKCDD27   ABOOT571   Clean Out Cap Kit   All models   ACAP570   1 This can be ordered from Tjernlund, part number SSII.   2 This can be ordered from Field Controls, part number SWG-5-CK61.   Evaporator Coil Cabinet   Model   A B ACOILKDCC19 19 1/2 22 1/8   ACOILKDCC22 22 1/2 23 1/4   ACOILKDCC27 24 24 1/4   Download from Www.Somanuals.com. All Manuals Search And Download.   Dimensions (in.)   Model   A B C D E F G H J K RLBF80C57/72   RLBF80C84/95   RLBF80C112/125   RLBR80C57/72   RLBR80C84/95   RLBR80C112/125   RLBR80C140/168   RLBR80C196   19 1/2   22 1/2   19 1/2   18   21   18   37   37   37   9 3/4   11 1/4   9 3/4   21   21   21   3 1/4   3 1/4   3 1/4   16   16   16   1 1/2   1 1/2   1 1/2   52 1/8   52 1/8   52 1/8   N/A   N/A   27   22 1/2   24   26   21   22 1/2   24 1/2   37   39   42   11 1/4   12   13   21   23 1/8   24 1/2   3 1/4   2 1/4   2 7/16   16   18   23   1 1/2   1 7/8   52 1/8   54 3/4   61 1/8   29   29   32   Clearances (in.)   Model   RLBF80C57/72   Front* Sides   Rear   RLBF80C84/95   RLBF80C112/125   RLBR80C57/72   RLBR80C84/95   4 6 24   RLBR80C112/125   RLBR80C140/168   RLBR80C196   *Clearance from combustibles.   All specifications and illustrations   subject to change without notice and   without incurring obligations..   For more information, contact your local Ducane distributor.   Form No. DRLUF-R80C-100 (7/06)   Printed in U.S.A.   ©Allied Air Enterprises, A Lennox International company 2006   *DRLUF80C-100-7-06*   Download from Www.Somanuals.com. All Manuals Search And Download.   |