| Operating Instructions   85601 Issue 5   Dimplex DuoHeat Radiator   Models: Duo300i, Duo400i and Duo500i   Shelf or Overhang   Curtains   Dimensions (millimetres)   Models   Specification   1.3kW / 0.28kW   1.95kW / 0.34kW   2.6kW / 0.39kW   Rated Charge   9.1kWh   300i   250mm   min.   400i   13.65kWh   18.2kWh   75mm   min.   C B 500i   Height   A Width   B Depth   C Model   Duo300i   Duo400i   Duo500i   712mm   712mm   712mm   600mm   830mm   1060mm   130mm +10mm   130mm +10mm   130mm +10mm   75mm   min.   150mm   min.   A Furniture   or other   obstruction   Radiator Positioning A minimum clearance of 150mm to the   front of the radiator is essential for safety, however to enable the   radiator to attain its maximum performance ensure that any   furniture or other obstruction is not placed closer than 250mm.   110mm   THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE   IMPORTANT SAFETY INFORMATION   WARNING - THE SURFACE OF THIS RADIATOR CAN BE HOT.   The surface temperatures of this radiator are within the requirements of EN60-335 the European Standard covering the safety   requirements of electric heating appliances, and momentary contact with any part of the radiator should not cause injury.   However, in order to be effective, radiators of any type do get hot, especially around the air outlet grille.   Therefore, if aged or infirm persons, or young children, are likely to be left unsupervised in the vicinity of a radiator   precautions should be taken to ensure that prolonged contact with the radiator cannot occur. We recommend that a   guard is fitted around the radiator, as is normal with some types of heating appliances in similar circumstances. If you require   further information on these guards, please contact Dimplex Customer Services on 0870 7270 101.   • WARNING - IN ORDER TO AVOID OVERHEATING, DO NOT COVER THE SURFACES OF THE RADIATOR AND DO   NOT OBSTRUCT AIR OUTLET GRILLES Surfaces of the radiator should not be covered or obstructed as this can cause   excessive temperatures that can be hazardous and may cause safety cut-outs to operate. For example, do not put clothes,   fabrics or any combustible materials on the radiator or allow curtains to come within 75mm (3”) of the top and ends of the   radiator. Do not allow furniture to be pushed up against the radiator, a minimum clearance of 150mm is critical for safety,   however to ensure radiator performance is not affected a clearance of 250mm is recommended.   DO NOT PLACE OBJECTS IN CONTACT WITH THE RADIATOR   • WARNING – The radiator must not be located below a socket outlet.   • PLEASE NOTE: THIS RADIATOR IS HEAVY AND MUST BE SECURELY FIXED TO A SOUND WALL. No attempt   should be made to move the radiator without first seeking specialist advice. If you are not happy that the radiator has   been securely fixed, please inform your installer.   UNDER NO CIRCUMSTANCES SHOULD YOU ATTEMPT TO MOVE THE RADIATOR OR LOOSEN WALL FIXINGS   WITHOUT FIRST REMOVING ALL ENERGY RETENTION CELLS FROM THE RADIATOR.   • DO NOT SIT OR STAND ON THE RADIATOR.   • DO NOT SPILL LIQUIDS ONTO THE APPLIANCE. IF YOU DO, SWITCH THE RADIATOR OFF AND GET A QUALIFIED   ELECTRICIAN TO CHECK IT.   • DO NOT POKE OBJECTS THROUGH THE GRILLE.   • DO NOT PLACE OBJECTS IN THE SPACE BEHIND THE RADIATOR.   • DO NOT USE POLISHES ON THE RADIATOR OR ON FURNITURE NEAR TO IT. The hot interior of the radiator can   produce paraffin smells from polish vapours which may last for a number of hours.   • In case of breakdown or other failure, switch off the radiator at both wall switches and contact your supplier or Dimplex Customer   Services. Always ensure that the radiator is switched off at the wall and fuse is removed before any repair is carried out.   • IMPORTANT - Due to the newness of the materials the radiator will produce a slight smell for the first few days of operation.   ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS OR PERSONS WITH RESPIRATORY   COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE RADIATOR DURING THE FIRST 48 HOURS OF   THE COMMISSIONING PERIOD. Running the radiator at maximum temperature for the first few days will help to dispel   any smells more quickly.   Download from Www.Somanuals.com. All Manuals Search And Download.   Everyday Operation   Child Lock Operation   Once the Background level has been set (see Achieving   Optimum Comfort Level above), this should not require any   further adjustment.   To activate the child lock simultaneously depress the   and   + -   buttons for a period of 3 seconds. After this period the child lock   is in operation and the LED will illuminate for short period and   then revert to the setback setting. The LED beside the key symbol   will illuminate while the child lock is in operation.   Adjust the Comfort setting as required to suit your comfort needs   and occupancy pattern. For a short period of non occupancy   the control can be lowered slightly (we recommend by no more   than 2 bars) to save energy when the room is unoccupied and   increased again when more heat is needed.   Once in the locked position, if either of the controls are operated   the LED will resume maximum illumination for a short period before   reverting back to the setback position.   Non Occupancy (vacant)   To deactivate the child lock, depress the buttons simultaneously   again for 3 seconds and the buttons will become active.   For long periods of non occupancy, reduce the Background   and the Comfort to their lowest settings.   It will take 24 hours for room temperature to reach a   comfortable level when resetting from Low settings to   Normal settings.   Safety - Overheat Protection   For your safety, this appliance is fitted with thermal cut-outs. In   the event that the product overheats, the cut-outs switch the   radiator off automatically. In the event of these safety cut-outs   activating please inform the installer or Dimplex Customer Services   for advice in order to reset the cut-outs.   Two Zone Wall Mounted Programmer (only applicable if Programmer is fitted to DuoHeat installation)   RX010006 - Pilot Wire, or   RX010007 - Mains Borne Signalling   The programmer has two modes (i) AUTO or (ii) MANUAL   (i)   In “Auto” mode, the radiator will change between Comfort and Setback modes (as shown in the table below) depending   on your seven day programme. To change the programme settings or temporarily over ride the programme, see the   appropriate programmer instructions.   (ii)   “Manual” mode will override the auto programme setting. There are four “Manual” mode settings shown in the table below.   Programmer Mode   Temperature Setting   DuoHeat Radiator –   “Temperature control display setting”   Comfort Setting (radiator setting). Each   Radiator will operate as set in “controls”   section of Operating Instructions.   Comfort   Display will remain as shown in Quick Start Guide   Setback will reduce the Comfort setting by   2°C, and will leave the Background   unaffected.   Display will show two red bars less.eg. if “Comfort”   displays 5, “Setback” will display 3 red bars.   Setback   H Frost Protect   Room temperature will be maintained at   16°C with Background operating.   Display will show one red bar.   Display will show one red bar.   J This will completely switch off radiators,   e.g. during the summer heating may not be   required.   Off   Note:   It will take 24 hours for room temperature to reach a comfortable level when resetting   from “Setback”, “Frost Protect”, “Off” to “Comfort”.   Download from Www.Somanuals.com. All Manuals Search And Download.   Cleaning   To maintain the external appearance of the radiator it need only be wiped over occasionally with a dry duster. During the summer months,   or at other times when the appliance is not is use and is completely cold, the opportunity should be taken to wipe over with a damp cloth.   Do not use abrasive cleaning powders or furniture polish.   Discoloration of wall finishes can sometimes occur immediately above a radiator due to the properties of some paints and decorating   materials or the presence of environmental impurities in the air (such as soot or incense generated from the burning of candles etc.).   After Sales Service   Your Dimplex DuoHeat radiator is guaranteed for two years from date of purchase. We undertake to exchange or repair free of   charge within this period any part found to be defective due to a manufacturing fault. This guarantee in no way prejudices your rights   under common law.   Should you require after sales assistance, please contact Dimplex Customer Services on the number listed below.   Please do not return a faulty appliance or part of an appliance to us as this may result in transit damage and/or delay in providing   service. Let us know the difficulty quoting the products model and serial numbers. We will then take the appropriate action.   This appliance complies with the European Standards EN 60 335-1, EN 60 335-2-61, EN 61000-3-2,   EN 61000-3-3, EN 55014 and EN55104 for Safety & Electromagnetic Compatibility.   These standards cover the requirement of the EMC Directives 89/336 & 73/23   Glen Dimplex UK Limited   Millbrook House   Grange Drive   Hedge End   Southampton   Customer Help Line   8am–5pm Mon–Fri and 8:30am–1pm Sat (Autumn–Winter only)   Fax   Web-site   e-mail   0845 600 5111   01489 773 050   01 842 4833   Republic of Ireland   Hampshire SO30 2DF   © Glen Dimplex UK Limited   All rights reserved. Material contained in this publication may not be reproduced in whole or part, without prior permission in writing from Glen Dimplex UK Limited.   Download from Www.Somanuals.com. All Manuals Search And Download.   |