IMPORTA N T SA FETY IN STRUCTION S  
READ AND FO LLO W ALL INSTRUCTIONS CAREFULLY  
When installing and using this equipment, basic safety precautions should always be followed, including:  
Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by  
children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at  
all times.  
Danger  
A grounding wire connector is provided on this spa to connect a minimum No. 8 AWG (8.4 mm2)  
solid copper conductor between this unit and any metal equipment, metal enclosures of electrical  
equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the spa.  
W arning  
Risk of Serious Injury or Death. The suction fittings in this spa are sized to match the specific water  
flow created by the pump. Should the need arise to replace the suction fittings or the pump, be sure  
that the flow rates are compatible.  
Danger  
Never operate the spa if the suction fittings are broken or missing. Never replace a suction fitting  
with one rated less than the flow rate marked on the original suction fitting.  
Risk of Electric Shock. Install at least 5 FEET (1.5 m), from all metal surfaces. As an alternative, a spa  
may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a  
minimum No. 8 AWG (8.4 mm2) solid copper conductor attached to the wire connector on the  
grounding lug, inside the equipment compartment on the equipment can.  
Danger  
Risk of Electric Shock. Do not permit any electrical appliance, such as a light, telephone, radio,  
television, etc. within 5 feet (1.5 m) of a spa.  
Danger  
The electrical supply for this spa must include a suitably rated switch or circuit breaker to open all  
ungrounded supply conductors to comply with section 680-42 of the National Electrical Code,  
ANSI/NFPA 70-1993. The disconnect must be readily accessible and visible to the spa occupant but  
installed at least 5 feet (1.5 m), from the spa water.  
Danger  
To Reduce the Risk of Injury: The water in a spa should never exceed 104° F (40° C). Water  
temperatures between 100° F (38° C) and 104° F (40° C) are considered safe for a healthy adult.  
Lower water temperatures are recommended for young children and when spa use exceeds 10  
minutes.  
W arning  
To Reduce the Risk of Injury:  
Since excessive water temperatures have a high potential for causing fetal damage during the early  
months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to  
100° F (38° C).  
W arning  
To Reduce the Risk of Injury:  
Before entering a spa, the user should measure the water temperature with an accurate  
thermometer since the tolerance of water temperature-regulating devices may vary as much as +/-  
5° F (2° C).  
W arning  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
To Reduce the Risk of Injury:  
The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with  
the possibility of drowning.  
W arning  
W arning  
W arning  
W arning  
To Reduce the Risk of Injury:  
Persons suffering from obesity or with a medical history of heart disease, low or high blood  
pressure, circulatory system problems, or diabetes should consult a physician before using a spa.  
To Reduce the Risk of Injury:  
Persons using medication should consult a physician before using a spa since some medication may  
induce drowsiness, while other medication may affect heart rate, blood pressure, and circulation.  
Do not attempt to remove the light housing cover without lowering the water level below the light  
housing cover.  
Do not block air intakes located on the front left corner underneath the hot tub (the front right  
corner for the Chairman II and Triad II) and under the equipment access panel. Resulting  
malfunctions are not covered under warranty.  
W arning  
H yp e r t h e r m ia  
Prolonged immersion in hot water may induce hyperthermia. A description of the causes, symptoms, and effects of  
hyperthermia are as follows: Hyperthermia occurs when the internal temperature of the body reaches a level  
several degrees above the normal body temperature of 98.6° F, or 37° C. The symptoms of hyperthermia include  
dizziness, drowsiness, lethargy, and fainting. The effects of hyperthermia include:  
Failure to perceive heat,  
Failure to recognize the need to exit spa,  
Unawareness of impending hazard,  
Fetal damage in pregnant women,  
Physical inability to exit spa,  
Unconsciousness resulting in the danger of drowning.  
The use of alcohol or drugs can greatly increase the risk of fatal hypothermia in hot tubs and spas.  
W arning  
Persons suffering from heart disease, diabetes, high or low blood pressure, any condition  
requiring medical treatment, pregnant women, the elderly, or infants should consult with a  
physician before using a spa.  
Caution  
The consumer products safety commission has stated that the water temperature in a spa or hot  
tub should not exceed 104° F (40° C). Immersion in water in excess of 104° F (40° C) can be  
hazardous to your health.  
Caution  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Observe a reasonable time limit when using the spa. Long exposures at higher temperatures can  
cause high body temperature. Symptoms may include dizziness, nausea, fainting, drowsiness, and  
reduced awareness. These effects could result in possible drowning.  
Caution  
Caution  
Caution  
Caution  
Caution  
Caution  
Do not use the spa under the influence of alcohol, narcotics, or other drugs. Use of the spa  
under these conditions may lead to serious consequences.  
Always test the hot tub water temperature before entering the spa. Enter and exit the spa slowly.  
Wet surfaces can be very slippery.  
Never bring any electrical appliances into or near the spa. Never operate any electrical appliances  
from inside the spa or when you are wet.  
Proper chemical maintenance of spa water is necessary to maintain safe water and prevent  
possible damage to spa components.  
Use the spa straps and clip tie downs to secure the cover when not in use. This will help to  
discourage unsupervised children from entering the spa and keep the spa cover secure in high  
wind conditions. There is no representation that the cover, clip tie downs, or actual locks will  
prevent access to the spa.  
Do ’s a n d Do n ’t s  
DO test water temperature with your hand before entering to be sure that its comfortable.  
DO keep the spa cover closed when the spa is not in use. This is also the key to economical spa  
operation.  
DO check the operation of the equipment compartment cooling fan monthly, by activating a pump and  
checking for airflow out of the lower left or right front corner of spa.  
DONT block the equipment compartment vents. Blockage may cause damage to the spa equipment and  
will void the warranty.  
DONT block or sit on the filter recess area.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Wa r n in g Sign s  
Each spa has been provided with a Warning Sign and an Important Notice label.  
This label outlines safety precautions. This sign should be permanently placed in a location that is visible to the spa  
user. Replacement signs can be obtained from:  
Dimension One Spas  
2611 Business Park Drive  
Vista, CA 92083  
(760) 727-7727  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
H o t Tu b Fe a t u r e s  
Congratulations! You have purchased one of the finest portable hot tubs available. Take the time to read these  
instructions carefully. If installed and maintained properly your hot tub will provide many years of enjoyable,  
trouble-free operation. Read all of the instructions and view your owners manual video for further reference on  
hot tub operation. If you have any questions, please contact your local Authorized Dimension One Spas Dealer.  
The following features are included on your hot tub:  
Built to CE rating  
Completely self-contained with load sharing capabilities  
100% foam insulated  
All hot tub shells are formed from UltraLife™ high impact thermoplastic or Granitex™ Acrylic  
Designed for indoor or outdoor use  
Top access, easy to clean filter systems using “Standby” mode  
Water level referencing weir skimmer  
Handcrafted cabinets  
Proportional FastFlo™ Heater  
A variety of interchangeable jets  
Multiple jet systems with Selector Valve (except in the Aurora XLT, Aurora HP, Caliente HP, and Triad)  
Exclusive, custom hand-set ceramic tile adds a distinctive touch  
Polyethylene floor completely seals the hot tub, eliminating moisture or insect intrusion  
Built-in, automatic freeze protection  
Automatic high/low speed filtration cycles  
A d d it io n a l Fe a t u r e s fo r t h e Ch a ir m a n , Ch a ir m a n II,  
Dip lo m a t , Ca lifo r n ia n , N a u t ilu s, A u r o r a X LT, A u r o r a II,  
Ca lie n t e H P, a n d Tr ia d II  
Scrolling Message Center with digital display, instructional, and maintenance messages  
Ultra Pure™ Water Management System  
NeckFlex™ Jet Pillow  
Twin, long life, dual speed HydraMax® pumps  
150 sq. ft. (13.94 m2) of filtration  
A d d it io n a l Fe a t u r e s fo r t h e A r e n a , A u r o r a H P, Ca lie n t e , a n d  
Tr ia d  
Programmable Digital control with digital display  
CrystalZone™ Water Management System  
Long life, dual speed HydraMax pump  
75 sq. ft. (6.97 m2) of filtration  
Jet System Selector Valve  
All hot tubs (except the Aurora HP, Aurora XLT, Caliente HP, and Triad II) are equipped with spa-side Selector  
Valves, see Figure 1. These valves can be used to divert jet power from one area within the hot tub to another.  
The valves are adjustable and can be used to suit the bathers taste. The valves may offer some resistance to  
operation when the hot tub pump is on. This is a normal condition, and is caused by the high rate of water flow  
and pressure that travels through the valves.  
Figure 1. Selector Valve  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
NeckFlex Jet Pillow  
The NeckFlex Jet Pillow, Figure 2, offers five height adjustable positions to accommodate different body sizes. The  
standard mini directional jets can be interchanged with rotating jets and are adjustable for water volume. See your  
local Authorized Dimension One Spas for more information.  
Figure 2. NeckFlex Jet Pillow  
Ultra Pure W ater Managem ent System  
The Chairman II, Caliente HP, Diplomat, Chairman, Californian, Nautilus, Aurora II, Aurora XLT and Triad II are  
equipped with a highly advanced hot tub water treatment method, the Ultra Pure Water Management System.  
Ultra Pure is an integrated water management system with ozone injection, a contact chamber, 100% filtration, and  
heating on demand.  
CrystalZone W ater Managem ent System  
Specifically engineered for Dimension One spas, the CrystalZone Water Management System found in the Arena,  
Triad, Caliente, and optionally on the Aurora HP, provides an integrated ozone purification and filtration for hot  
tubs. It maintains the pre-set hot tub temperature, without the use of a jet pump. Using a Mazzei-T ozone injector,  
the CrystalZone Water Management System provides cleaner water at lower operating costs. Youll spend more  
time enjoying your hot tub and less time maintaining it.  
Vision System s  
Vision Cartridge, an alternative purification system, can be used in conjunction with your Ultra Pure or  
CrystalZone Water Management Systems. The advantage of Vision over conventional halogens (bromine and  
chlorine) is that it will, as a result of lower chemical use, provide softer-feeling water. Additionally, low chemical  
levels can mean fewer dissolved solids, which results in less water chemistry maintenance. Please refer to the  
Vision instructions for proper installation. Also read Water Care section for more information.  
Heater and Circulation Pum p Control  
On all Dimension One Spas, when the water temperature is 1° F (0.55° C) below the set temperature the heater  
will turn on and remain on until the water temperature rises to 1° F (0.55° C) above the set temperature. To  
prevent the hot tub from overheating, the circulation pump turns off when the water temperature rises 2° F (1.1°  
C) above the set temperature. When the water temperature cools down to the set temperature, the circulation  
pump will turn on.  
The circulation pump will run for short periods when the water temperature is 2° F (1.1° C)  
above set temperature to provide optimum operation. (The circulation pump is optional on the  
Aurora HP.)  
Note  
Sm art Heat (Available only on Dim ension O ne Spas)  
Smart Heat optimizes heat recovery using the amperage that you have available. Along with computerized load  
sharing, that automatically recognizes the number of jet pumps in use, compares it with the available power, Smart  
Heat recognizes the difference between the set temperature and the actual water temperature, and adjusts the  
heater to optimize the heater output.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Op e r a t io n  
Operation is divided into two sections: Programming the Digital Control for the Arena, Aurora HP, Caliente, and  
Triad (following section) and Programming the Scrolling Message Center for the Aurora II, Aurora XLT, Caliente  
HP, Californian, Chairman, Chairman II, Diplomat, Nautlilus, and Triad II (proceed to the Programming the  
Pr o gr a m m a b le Digit a l Co n t r o l fo r t h e A r e n a , A u r o r a H P,  
Ca lie n t e , a n d Tr ia d  
Advanced microprocessor technology has been utilized to produce the Programmable Digital Control. Easy to use  
and understand, Dimension One Spas has put every hot tub function within fingertip control. Temperature setting,  
jet power control, and the hot tub light are all spa-side accessible. That means you dont have to get out of the hot  
tub to enjoy complete control of all hot tub functions. Safety is assured through design concepts and materials that  
meet or exceed CE rating.  
Digital Control, Figure 3, lets you relax and enjoy everything your hot tub has to offer.  
Gain a thorough knowledge of the following information before starting up your spa  
Note  
Figure 3. Digital Control  
Top Side Control  
Control  
Function  
1
1. Digital Display  
The digital display indicates (depending on program mode) temperature in  
degrees F or C, time, filter cycle start time, filter cycle duration time, and  
number of filter cycles. For more information see “Digital Display Messages”.  
2. JETS (Low/High Control) Pad  
2
When the JETS pad is pushed, the hot tub jet pump is energized and the JETS  
Status Light (1) will illuminate. Each time the pad is pushed it will activate a 30  
minute automatic shut-off cycle. This auto shut-off cycle is a safety device and  
also allows for convenient filtration immediately after using the hot tub. The  
first time a pad is pushed the pump is turned on. When the same pad is pushed  
again, the pump will turn off.  
NOTE: Pushing the JETS pad will disable any concurrent filter cycle.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Control  
Function  
3
3. LIGHT Pad and Status Light Push the LIGHT pad once to activate the  
brightest setting (Status Light will illuminate, 1). A second push will activate the  
medium setting and a third push will activate the dimmest setting. Push the  
LIGHT pad a fourth time to turn off the light. The light will automatically turn  
off after one hour.  
NOTE: If the Dynamic L.E.D. Light is installed, the low, medium, and high  
settings are disabled. The Light pad turns the Dynamic L.E.D. Light on and off.  
4.TEMPERATURE Pads  
4
Pushing the UP (+) pad increases the temperature and pushing the DOWN (-)  
pad decreases the temperature. Push the respective pad one time for each  
degree of temperature change, or push and hold the pad for rapid adjustment.  
The actual hot tub water temperature will remain in the Digital Display  
window until a temperature pad is pushed. When the UP or DOWN pad is  
pushed the Digital Display will indicate the new temperature setting, with the  
SET POINT Icon on the right side of the Digital Display. Once the new  
temperature is set, the actual hot tub water temperature will again be  
indicated. The hot tub will heat to the pre-set temperature automatically.  
5
5. PRO GRAM Pad  
The PROGRAM pad is used for several different functions including: Clock Set,  
Filter Cycle Start Time, Filter Cycle Duration, Number of Filter Cycles, and  
Temperature Unit Selection. The paragraphs following this table will explain  
how these features are set.  
To initiate the programming sequence at any time, push and hold the  
PROGRAM pad for 3 seconds. If, within 60 seconds, you do not proceed with  
the hot tub programming, the hot tub will automatically exit the programming  
sequence and revert to the previous settings. To exit the programming  
sequence at any time, do not press any pad for 10 seconds. Any programming  
changes made up to that point will be saved.  
6
7
6. Dim ension O ne Spas ICO N (Logo)  
The time of day can be viewed by pushing the Dimension One Spas ICON logo  
on the far right of the control. If no other pad is pushed within 5 seconds, the  
display will revert to the hot tub water temperature reading. The pre-set  
factory default is Fahrenheit.  
Pressing the logo for 5 seconds will place the spa in the “Standby” mode and  
allow the spa to be cleaned without turning off the power.  
7. Heat Status Light  
This Light is illuminated whenever the heater is on.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2002 Dimension One Spas Export Owners Manual  
Digital Display Messages  
The following messages may appear in the Digital Display:  
“OH” – Overheat Protection  
When “OH” is displayed on the control system Digital Display, the hot tub is in a high temperature condition. If  
such a condition exists, check water temperature and if it is above 104° F (40° C), DO NO T ENTER THE  
W ATER. If this happens, remove the hot tub cover and allow the water to cool below 110° F (43.3° C). Reset  
the power to the spa by resetting the GFCI breaker. If the problem recurs, turn off all power to the hot tub and  
contact your local Authorized Dimension One Spas Dealer, or authorized service center.  
Flashing LED on the Control Panel  
If you see 3 flashing LEDs on the Digital Display, check the water temperature and if it is above 104° F (40°C) DO  
NO T ENTER THE W ATER. The system has detected a problem. Check the Digital Display and if it is  
displaying the “OH” symbol, contact your local Authorized Dimension One Spas Dealer, or authorized service  
center. If the Digital Display is displaying the temperature, check the water level and clean the filters. If the  
problem persists, reset the power to the spa by resetting the GFCI breaker. If the error is not resolved after  
resetting the spa, contact your local Authorized Dimension One Spas Dealer, or authorized service center.  
Flashing Temperature on the Display  
If you see a flashing temperature of 34° F (-16.6° C) or 134° F (56.6°C), DO NOT ENTER THE WATER. The  
system has detected a problem. Contact your local Authorized Dimension One Spas Dealer, or authorized service  
center.  
Summer Mode  
The “SUMMER MODE” feature temporarily disables the circulation pump “Cool Off” cycle. During hot weather  
the spa can experience “Heat Creep”. Heat creep is caused when the spa, during normal maintenance operations,  
cannot dissipate more heat than is generated. This may cause the spa temperature to exceed the set temperature  
and cause a “Cool Off” cycle. In order to prevent the water from becoming cloudy due to the circulation pump  
being turned off by the “Cool Off” cycle, the spa can be set to bypass the “Cool Off” cycle. This is accomplished  
by setting the spa in the “SUMMER MODE. To initiate a “SUMMER MODE, use the Up and Down pads to set  
the temperature to 59° F (15° C). The Digital Display will indicate “SUMMER MODE”. In this mode the pump will  
run continuously until the water temperature reaches 107°F (41.67° C) and then turns off. It will remain off until  
the water temperature reaches 102° F (38.39° C) at which point the pump turns on.  
Standby Mode  
The “STANDBY” mode allows the user to clean the filter without turning off power to the spa. This feature  
disables all automatic and manual functions.  
To enter the “STANDBY” mode press and hold the Dimension One Spa”s ICON logo for 5 seconds. To exit the  
mode, press and hold the logo for 5 seconds. If you do not exit the mode manually, the spa will automatically  
return to normal functionality after 24 hours.  
The “Smart Winter” mode is not affected by the use of the “Standby”: mode.  
Note  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Using the Program m able Digital Controller  
To initiate the programming sequence at any time, push and hold the Program Pad for 3 seconds. If, within 10  
seconds, you do not proceed with the hot tub programming, the hot tub will automatically exit the programming  
sequence and revert to the pre-set factory default settings. To exit the programming sequence at any time, do not  
press any pad for 10 seconds. Any programming changes made up to that point is saved.  
Clock Set  
Push and hold the Program Pad for 3 seconds to engage the time setting mode. The time screen will appear with  
“hours” (__.00) flashing on and off. Push the Up Pad or Down Pad to increase or decrease the number until the  
desired hour appears in the Digital Display. When the desired number is displayed, push the Light Pad to accept  
the selection and change the flashing number to the “ten minute” place (12:_0). Adjust the number with the Up or  
Down Pads in the same manner as the hour number. When the desired number is displayed, push the Light Pad to  
accept the selection and change the flashing number to the “minute” place (12:1_). Adjust this number with the Up  
or Down Pad in the same manner as the hour number. When the desired number is displayed, push the Light Pad  
to accept the selection and change the flashing number to a flashing AM or PM indicator. Adjust the indicator with  
the Up and Down Pads. When the desired indicator is displayed, push the Program Pad to accept the selection and  
enter the Filter Cycle Start Time programming mode.  
Filter Cycle Start Time  
To adjust the filter cycle start time, push the Up or Down Pads and Light Pads as done in the Clock Set  
programming mode to choose a time. Once the desired time is displayed, push the Program Pad to accept the  
selection and move into the Filter Cycle Duration programming mode.  
You will be prompted later to set the filter cycle duration and the number of filter cycles. Be sure  
to keep this in mind when programming your filter cycle start time. During the filter cycle, JET 1  
will activate at high speed for the duration of the filter cycle.  
Note  
Filter Cycle Duration  
To adjust the filter cycle duration, push the Up or Down Pads to cycle through the choices of 60, 90, 120, 150 or  
180 minutes (the default is 60). Once the desired time is displayed, push the Program Pad to accept the selection  
and move into the Number of Filter Cycles programming mode.  
Long and/or numerous filter cycles could cause overheating of the hot tub - especially in hot  
climates.  
Caution  
Number of Filter Cycles  
To adjust the number of filter cycles per day, push the Up or Down Pad to cycle through the number of filter  
cycles - 1, 2, 3 or 4 (the default is 2). Once the desired number of cycles is displayed, push the Program Pad to  
accept the selection and move into the Temperature Unit Selection programming mode.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Temperature Unit Selection  
To select temperature units push the Up or Down Pads to toggle between ° F (degrees Fahrenheit) or ° C  
(degrees Celsius). Once the desired temperature unit is selected push the Program Pad to exit the programming  
mode.  
The time of day can be viewed by pushing the Dimension One Spas logo on the far right of the  
control. If no pad is pushed within 5 seconds, the display will revert to the hot tub water  
temperature reading. The pre-set factory default is Fahrenheit.  
Note  
Initial Startup  
Please proceed to the Initial Startup section for details on preparing for your initial startup.  
Pr o gr a m m in g t h e Scr o llin g Me ssa ge Ce n t e r fo r t h e A u r o r a II,  
A u r o r a X LT, Ca lie n t e H P, Ca lifo r n ia n , Ch a ir m a n , Ch a ir m a n  
II, Dip lo m a t N a u t ilu s, a n d Tr ia d II  
Advanced microprocessor technology has been utilized to produce the Scrolling Message Center. The most  
technologically advanced hot tub control in the world is also the easiest to operate. Dimension One Spas has put  
every hot tub function within fingertip control. Temperature setting, jet power control, the hot tub light and all  
other functions are spa-side accessible. That means you dont have to get out of the hot tub to enjoy complete  
control of all hot tub functions. Safety is assured through design concepts and materials that meet or exceed the  
most stringent requirements of the CE rating. The Scrolling Message Center lets you relax and enjoy everything  
your Dimension One spa has to offer.  
Gain a thorough knowledge of the following information before starting up your spa  
Note  
Figure 4. Scrolling Message Center  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Top Side Control  
Control  
Function  
1. Digital Display (LCD)  
1
The Digital Display continuously shows the operating status of the hot tub, as  
well as the various monitoring functions, self-diagnostics, and programming  
information.  
JETS 1 and 2 Pads (1)  
2
When either JETS pad is pushed, the corresponding spa jet pump is energized,  
the respective Digital Display indicator light will be illuminated, the pump speed  
will be indicated on the lower left of the Digital Display and a rotating swirl icon  
will be displayed in the upper left corner of the Digital Display. The rotation  
speed of the swirl will vary according to the pumps speed. The first time a JETS  
pad is pushed the respective pump will turn on. When the same pad is pushed  
again, the pump will turn off.  
Each time a JETS pad is pushed it will activate a programmable, automatic shut-off  
cycle. The default time is 30 minutes. A progress bar for each pump will indicate  
the time remaining before the pump will turn off. This auto shut-off cycle is a  
safety device and also allows for convenient filtration immediately after use of the  
hot tub  
3.LIGHT Pad (1)  
3
Push LIGHT pad once to activate the brightest setting. A second push will  
activate medium setting and a third push will activate the dimmest setting. A  
message indicating current light intensity will scroll twice on the bottom left of  
the Digital Display (i.e. LIGHT HIGH, LIGHT MEDIUM, LIGHT LOW) and an  
animated icon, with zero, three or six dots around it indicating the lights  
intensity will be displayed. Push the LIGHT pad a fourth time to turn off the light.  
The light will automatically turn off after one hour.  
NO TE: If the optional Dynamic L.E.D Light is installed, the low, medium and  
high settings are disabled. The Light pad turns the Dynamic L.E.D Light on and  
off.  
4. TEMPERATURE Pad  
4
When the Up or Down pad is pushed to change the set temperature, the  
bottom left of the Digital Display will read “SET TEMP TO _ _ _° F”. When there  
is a call for heat, the Heat Status Light and Digital Display will turn on when the  
heater engages. This is a normal function. The right side of the Digital Display will  
read the current temperature and the bottom left will read “HEATING TO _ _  
_° F” until the hot tub reaches the set temperature. If the water reaches 2° F (-  
16.6° C) (above the set temperature, the message “COOLING TO _ _ _ - CIRC  
PUMP & O3 OFF” will be displayed in the bottom left hand side of the Digital  
Display and a cooling cycle will start.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Control  
Function  
5. ENTER Pad  
5
This pad is used to exit any programming sequence at any time.  
6. PRO GRAM Pad  
6
This pad is used to initiate the time setting, filter programming, and other  
programming features. For more information, see the next section,  
“Programming the Scrolling Message Center.”  
7. Dim ension O ne Spas ICO N (Logo)  
7
8
The time of day can be viewed by pushing the Dimension One Spas ICON logo  
on the far right of the control panel. If no other pad is pushed within 5 seconds,  
the display will revert to the hot tub water temperature reading. The pre-set  
factory default is Fahrenheit.  
Pressing the logo for 5 seconds will place the spa in the “Standby” mode and  
allow the spa to be cleaned without turning off the power.  
8. Heat Status Light  
This Light is illuminated whenever the heater is on.  
Scrolling Message Center (Digital Display) Messages  
Because of the advanced programming features of your scrolling display, your hot tub will prompt you when you  
need to perform routine maintenance. For example:  
Rinse Filters  
Every other month, the top line of your Digital Display will read, “RINSE FILTERS” and the message “REMOVE  
FILTERS & RINSE WITH HOSE... PUSH AND HOLD ICON PAD MORE THAN 3 SECONDS TO RESET THIS  
MESSAGEwill scroll from right to left on the bottom line of the display. To reset this message, push and hold the  
Dimension One Spas ICON (logo) located at the right hand side of the control for 3 seconds.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Clean Filters  
On alternating months, the top line of your Digital Display will read, “DIRTY FILTER” and the message “REMOVE  
FILTERS & CLEAN IN SOLUTION... PUSH AND HOLD ICON PAD MORE THAN 3 SECONDS TO RESET THIS  
MESSAGEwill scroll from right to left on the bottom line of the display. To reset this message, push and hold the  
Dimension One Spas ICON (logo) pad located at the right hand side of the control for 3 seconds.  
Change Water  
Every four months the top line of your Digital Display will read “CHANGE WATER” and the message “TURN  
POWER OFF, DRAIN & REFILL SPA...PUSH AND HOLD ICON PAD MORE THAN 3 SECONDS TO RESET  
THIS MESSAGE” will scroll from right to left on the bottom line of the display. To reset this message, push and  
hold the Dimension One Spas ICON (logo) pad located at the right hand side of the control for 3 seconds.  
Change Vision Cartridge  
When “CHANGE VISION CARTRIDGE” is displayed on the LCD, the system is telling you that it is time to  
replace it. To reset this message, push and hold the Dimension One Spas ICON (logo) pad located at the right  
hand side of the control for 3 seconds.  
If you purchased a Vision cartridge subsequent to the initial start up of your hot tub, please follow  
the programming instructions for VISION as outlined in the next section (titled, “Vision  
Cartridge”) to set the six-month time frame.  
Note  
Spa Check Up  
When “SPA CHECK UP” is displayed on the Digital Display, we recommend that you have your hot tub inspected  
by your dealer as a preventative maintenance measure. To reset this message, push and hold the Dimension One  
Spas ICON (logo) pad located at the right hand side of the control for 3 seconds.  
The system can dismiss and reset the maintenance messages by pushing and holding the  
Dimension One Spas ICON (logo), on the right end of the control, for 3 seconds. If you press the  
Dimension One Spas ICON (logo) for 5 seconds when there is no maintenance message, it will  
put the spa in the “Standby” mode.  
Note  
Overheat  
When “OVERHEAT” is displayed on the control system Digital Display, the hot tub is in a high temperature  
condition. If such a condition exists, check water temperature and if it is above 104° F (40° C), DO NO T  
ENTER THE W ATER. If this happens, remove the hot tub cover and allow the water to cool below 110° F  
(43.3° C). Reset the power to the spa by resetting the GFCI breaker. If the problem recurs, turn off all power to  
the hot tub and contact your local Authorized Dimension One Spas Dealer, or authorized service center.  
Flashing Display and/or “Check Water Level”  
If you see 3 flashing LEDs (on Digital Display) and/or the message, “CHECK WATER LEVEL -CLEAN FILTER-IF  
PROBLEM CONTINUES, TURN OFF POWER AND RESTART THE SYSTEM-IF PROBLEM CONTINUES, CALL  
FOR SERVICEon the Digital Display, follow the instructions as stated. Check the water temperature and if it is  
above 104° F (40° C), DO NO T ENTER THE W ATER.  
Flashing Temperature on the Display  
If you see a flashing temperature of 34° F (1.11° C) or 134° F (56.6° C), DO NOT ENTER THE WATER. The  
system has detected a problem. Call your dealer for service.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Ice  
When “ICE CONDITION” and the water temperature are displayed on the Digital Display, the air temperature in  
the equipment can has gone below a factory-preset level, and the system has activated “Smart Winter Mode.” It  
will then automatically activate the pump(s) to circulate water. This is a normal hot tub function. No corrective  
action is necessary. This feature protects the spa from freezing.  
Cooling  
When “COOLING” and the water temperature are displayed on the Digital Display, the water temperature has  
reached 2° F (1.1° C) above the set temperature. The circulation pump and ozone generator will turn off to allow  
the water to cool back to the set temperature. This is a normal hot tub function. No corrective action is  
necessary.  
The circulation pump and ozone generator will be on while either jet pump is on and they will remain  
on for 30 minutes after the pump(s) turn off regardless of the water temperature.  
Note  
The Dimension One Spas Scrolling Message Center will keep all programming for 40 years with no  
power supply and the time of day for 30 days. This battery back up will not provide power to heat or  
operate the hot tub.  
Note  
Summer Mode  
The “SUMMER MODE” feature temporarily disables the circulation pump “Cool Off” cycle. During hot weather  
the spa can experience “Heat Creep”. Heat creep is caused when the spa, during normal maintenance operations,  
cannot dissipate more heat than is generated. This may cause the spa temperature to exceed the set temperature  
and cause a “Cool Off” cycle. In order to prevent the water from becoming cloudy due to the circulation pump  
being turned off by the “Cool Off” cycle, the spa can be set to bypass the “Cool Off” cycle. This is accomplished  
by setting the spa in the “SUMMER MODE. To initiate a “SUMMER MODE, use the Up and Down pads to set  
the temperature to 59° F (15° C). The Digital Display will indicate “SUMMER MODE”. In this mode the pump will  
run continuously until the water temperature reaches 107°F (41.67° C) and then turns off. It will remain off until  
the water temperature reaches 102° F (38.39° C) at which point the pump turns on.  
Standby Mode  
The “STANDBY” mode allows the user to clean the filter without turning off power to the spa. This feature  
disables all automatic and manual functions.  
To enter the “STANDBY” mode press and hold the Dimension One Spa”s ICON logo for 5 seconds. To exit the  
mode, press and hold the logo for 5 seconds. If you do not exit the mode manually, the spa will automatically  
return to normal functionality after 24 hours.  
The “Smart Winter” mode is not affected by the use of the “Standby”: mode.  
Note  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Using the Scrolling Message Center  
Your Scrolling Message Center is the most advanced in the industry and can virtually walk you through customizing  
your hot tub to your exact needs. To initiate the programming sequence at any time, push and hold the Program  
pad for 3 seconds. If, within 10 seconds, you do not proceed with the hot tub programming, the hot tub will  
automatically exit the programming sequence and revert to the pre-set factory default settings. To exit the  
programming sequence at any time, push the Enter pad or do not press a pad for 10 seconds. Any programming  
changes made up to that point are saved.  
Setting the Time  
After holding the PROGRAM pad, the top line of the Digital Display will read “SET TIME OF DAY” and the  
bottom line will read “PUSH UP OR DOWN TO CHANGE - PUSH PROGRAM TO SELECT NEXT FUNCTION  
- PUSH ENTER TO EXIT ”. Push the UP or DOWN pads to engage the time setting mode. The time screen will  
appear with “hours” (_ _.00) flashing on and off. Push the UP or DOWN pad to increase or decrease the number  
until the desired hour appears. When the desired number is displayed, push the LIGHT pad to accept the selection  
and change the flashing number to the “ten minute” place (12:_0). Adjust the number with the UP or DOWN pad  
in the same manner as the hour number. When the desired indicator is displayed, push the LIGHT pad to accept  
the selection and change the flashing number to the “minute” place (12:1_). Adjust this number with the UP or  
DOWN pad in the same manner as the hour number. When the desired number is displayed, push the LIGHT pad  
to accept the selection and change the flashing number to a flashing AM or PM indicator. Adjust the indicator with  
the UP or DOWN pads. After reaching the correct time, push the PROGRAM pad to set the time and exit the  
time setting mode. You will then be prompted to set the filter start time.  
Filter Cycle Start Time  
After setting the time-of-day, the top line of the Digital Display will read “SET FILTER CYCLE TIME”. Push the UP  
or DOWN pads in the same manner as setting the clock to select the time you want your filter cycle to start.  
When your desired filter cycle start time is set in the display, push the PROGRAM pad to continue. The pre-set  
factory default is 12:00 p.m. to 1:00 p.m. repeating every 12 hours unless the number of filter cycles per day has  
been changed.  
Keep in mind that you will later be prompted to set the filter cycle duration and the number of  
filter cycles. Be sure to keep this in mind when programming your filter cycle start time.  
Note  
During a filter cycle, the bottom left of the Digital Display will read “SPA FILTERING”. During the filter cycle, JETS  
1 will activate, the first 5 minutes at high speed and the remainder of the filter cycle time at low speed. JETS 2 will  
also activate for 1 minute on high speed and then turn off.  
Filter Cycle Duration  
After setting the filter cycle start time, the top line of the Digital Display will read “SET CYCLE DURATION.  
Push the UP or DOWN pads to toggle between 60, 90, 120, 150 and 180 minutes. The first 5 minutes of the filter  
cycle will be at high speed and the remaining time at low speed. When your desired filter cycle length appears in  
the Digital Display, push the PROGRAM pad to select it. The pre-set factory default is 60 minutes.  
Number of Filter Cycles  
After setting the length of the filter cycle, you will be prompted to set the number of filter cycles. The top line of  
the Digital Display will read “SET # OF CYCLES. Push the UP or DOWN pad to toggle from 1 to 2 to 3 to 4  
cycles per day. When your desired number of cycles appears on the Digital Display, push the PROGRAM pad to  
select it. The pre-set factory default is 2 cycles per day.  
Long and/or numerous filter cycles could cause overheating of the hot tub - especially in hot  
climates.  
Caution  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Pump Run Time  
After setting the number of filter cycles, the top line of the Digital Display will read “SET PUMP RUN TIME”. Push  
the UP or DOWN pads to toggle between 30, 45 and 60 minutes. This sets the length of time the pump will run  
when a jets pad is pushed. For example, if you choose 45 minutes, when you push a jets pad, the pump will run for  
45 minutes before shutting down automatically. When your desired pump run time appears on the Digital Display  
push the PROGRAM pad to select it. The pre-set factory default is 30 minutes.  
Temperature Unit Selection  
After setting the pump run time, the top line of the Digital Display will read “SET TEMPERATURE UNITS”. Push  
the UP or DOWN pads to toggle from °F to °C. When your desired temperature unit appears in the Digital  
Display, push the PROGRAM pad to select it. The pre-set factory default is Fahrenheit.  
Vision Cartridge  
After setting the temperature units, the top line of the Digital Display will read “SET VISION CARTRIDGE”. Push  
the UP or DOWN pads to toggle between “Yes” and “No”. If you are currently using a Vision Cartridge select  
yes, if not, select no. Selecting “yes” will prompt the control to notify you when your cartridge needs replacement.  
When your desired selection appears in the Digital Display, push the PROGRAM pad to select it. The pre-set  
factory default is “No.”  
Digital Display (LCD) Invert  
The invert feature will flip the text on the Digital Display so it can be easily read from both inside and outside the  
hot tub. To invert the text, simply push the “ENTER” pad three times. To return the text to its original position,  
repeat this process - push the “ENTER” pad three times.  
Control Panel Lock  
To help prevent unauthorized use of the hot tub, the control panel may be locked. When the control panel lock is  
engaged, all programmed or default hot tub functions will operate normally but all control pads will not operate.  
When the panel is locked, the Digital Display will display this message: “ALL SPA FUNCTIONS LOCKED.”  
To lock the panel all the following pads must be pushed within  
3 seconds:  
1. Push the Dimension One Spas ICON (logo) pad.  
2. Push the Dimension One Spas ICON (logo) pad.  
3. Push the ENTER pad.  
Control Panel Unlock  
To unlock the panel: All the following pads must be pushed within 3 seconds:  
1. Push the ENTER pad.  
2. Push the ENTER pad.  
3. Push the Dimension One Spas ICON (logo) pad.  
When the last pad is pushed all pads will be active.  
Programming Lock  
The programming lock is to prevent unauthorized programming and water temperature adjustments. When the  
programming lock is engaged, all programmed or default functions will operate normally. Also, the hot tub user  
may operate the pumps, the hot tub light or view the time-of-day, but no programming changes may be made.  
When the programming lock is enabled, the Digital Display will scroll “PROGRAMMING LOCKED” twice on the  
lower left side of the display, then a lock icon will be displayed on the right side of the Digital Display To enable  
the programming lock, all the following pads must be pushed within 3 seconds:  
1. Push the Dimension One Spas ICON (logo) pad.  
2. Push the Dimension One Spas ICON (logo) pad.  
3. Push the PROGRAM pad.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Programming Unlock  
To unlock the Panel: The following pads must be pushed within 3 seconds:  
1. Push the ENTER pad.  
2. Push the ENTER pad.  
3. Push the Dimension One Spas ICON (logo) pad.  
When the last pad is pushed all pads will be active.  
Control Panel Reset  
This function is used to completely reset the clock and all other system variables to the factory defaults. Please  
keep in mind that this resets all maintenance messages (clean filters, change water, etc.) as if the hot tub is being  
installed the day of the panel reset. To reset the control system all of the following pads must be pushed within 3  
seconds:  
1. Push the ICON (logo) pad  
2. Push the ENTER pad  
3. Push the PROGRAM pad  
The top line of the Digital Display will read “RESET PROGRAMMING?”  
The bottom line of the Digital Display will read “IF SO, PUSH ICON”  
4. Push the Dimension One ICON pad to reset the entire control system to factory defaults or do not  
touch a pad for 10 seconds to exit.  
If you do not have an Aurora XLT, Chairman II, or the Triad II, proceed to the Initial Startup section.  
Dynam ic Massage Sequencerfor the Aurora XLT, Chairm an II and the Triad II  
The Dynamic Massage Sequencer, Figure 5, is located in the Ultra Lounge of the models mentioned above. The  
sequencer directs a succession of 14 jets to six separate muscle groups.  
When a sequence is chosen, a human figure with LED's defining each zone, will light, showing the active zones in  
that sequence. This allows you to preview the zones in the sequence before a selection is confirmed.  
Control Panel Description  
Figure 5. Dynam ic Massage Control  
Control  
Function  
1. LIGHT Pad  
1
The LIGHT pad controls the spa light. Status light illuminates when light is on.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Control  
Function  
2. JETS Pad  
2
Operates the jet pump associated with the Massage Sequencer. Status Light  
illuminates when pump is on.  
3
3. SPEED Pad  
The SPEED pad is used to change the time between each step in all sequences.  
The default time is factory programmed for 5 second intervals. The first push of  
the SPEED pad will change the step interval time to 15 seconds, the second push  
will change the intervals to 30 seconds and the third push will reset the speed to  
5 second intervals. The LED indicator below the SPEED pad will blink at the speed  
at which the system is operating. During a Pause condition the Speed LED  
indicator will be OFF  
4
4.BEGIN/PAUSE Pad  
The BEGIN/PAUSE pad is used to interrupt the massage sequence and to start a  
particular sequence. For example, if the user likes the jet massage at a particular  
moment during the sequence, and wants to keep it for an extended period of  
time, the user may press the Begin/Pause pad and the system will remain in the  
specific configuration until the pad is pushed again. The Begin/Pause status light  
will be on when the system is in the Pause mode. During this mode, the matrix of  
LED's will preview the sequence and the user may also push the SEQUENCE pad  
to preview another sequence  
5
5.SEQ UENCE Pad  
The SEQUENCE pad is used to toggle between selected massage sequences.  
When a sequence has been selected, the corresponding LED indicator 1-6 will  
light. The default mode (all jets in the lounge operating) will not be indicated by a  
light  
6
7
6.Massage Zone Indicator Lights (Hum an Figure)  
When a sequence is chosen, one or more LED in the figure will illuminate  
showing the active zones in that sequence.  
7.SEQ UENCE Indicator Lights (1 through 6)  
When a sequence has been chosen the corresponding light will illuminate. When  
the default mode (all jets in the lounge operating) is selected, no light will be  
illuminated.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2002 Dimension One Spas Export Owners Manual  
Massage Zone Description  
The Dimension One Spas Dynamic Massage Sequencer lets you enjoy a wide variety of massage patterns on the  
most critical muscle groups of-your body. You can choose six automatic jetting sequences, with six different zones,  
for a completely personalized hydrotherapy, see Figure 6.  
Figure 6. Massage Zones  
Zone 1  
This zone is designed to massage neck and deltoid muscle groups with the NeckFlex Jet Pillow. There are two  
directional mini jets on the NeckFlex Jet Pillow carrier, which can be adjusted to five different heights in order to  
accommodate a variety of body sizes. The mini jets are water volume controllable, interchangeable with rotating  
jets and provide a narrowly focused massage pattern.  
Zone 2  
This zone is designed to massage the upper back, shoulders and thoracic muscle groups. There are two Variable  
Circulation Rotating jets (VCR) which are water volume controllable and interchangeable with directional jets.  
These jets can be adjusted to change the area of coverage and the speed of the rotational pattern.  
Zone 3  
This zone is designed to massage the middle back. There are two VCR jets that are water volume controllable and  
interchangeable with directional jets. These jets provide a high speed, pulsating feel and are excellent therapy for  
back muscles.  
Zone 4  
This zone is designed to massage the lower back and lumbar muscle groups. There are two directional VCR Jets  
that are water volume controllable and interchangeable with rotating jets. The directional HydraFlex jet also  
provides an adjustable nozzle that can eliminate air induction. This adjustment allows the user to control the water  
velocity or the intensity of the massage at each individual jet, without the need for cumbersome valves that also  
control jets in other areas of the spa.  
Zone 5  
This zone is designed to massage the back of the legs at the knee area, lower thighs, upper calves, and hands.  
There are four mini VCR jets that are water volume controllable, interchangeable and provide a narrowly focused  
massage pattern.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Zone 6  
This zone is designed to massage the feet. There are two directional mini VCR jthat are water volume controllable,  
interchangeable with rotating jets and provide a narrowly focused massage pattern.  
Operating the Dynamic Massage Sequencer  
1. Push the JETS pad to turn on the spa pump.  
2. Using the SEQUENCE pad toggle between the selected massage sequences. Select the sequences by  
pressing the BEGIN/PAUSE pad. A selected sequence is be indicated by an illuminated SEQUENCE  
Indicator Light (1 through 6).  
If the time between sequence changes is too fast or too slow, you can push the SPEED pad to increase  
or decrease the time between sequence changes. Five seconds is default. Other speeds available are  
15 and 30 seconds.  
Note  
Initial Startup  
1. Locate the Top Side Control. Directly below this control is the equipment compartment..  
2. Use screwdriver to remove the spa panel screws, Figure 7.  
Figure 7. Panel Screws  
The number of screws to be removed will depend on the make and model of spa.  
Note  
3. Locate the hose bib, Figure 8, that is included in the owners manual  
packet (located in the equipment compartment.).  
Figure 8. Hose Bib  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
4. Screw the hose bib onto the male fitting located  
at the bottom of the hot tub on the pedestal,  
Figure 9, to the lower left of the equipment  
compartment.  
1. Location of Male Hose Fitting  
Figure 9 Male Hose Fitting  
5. Close the valve on the side of the hose bib and screw the cap onto the end of the hose bib.  
6. Check the pump unions, Figures 10 and 11, to be sure that they are tight to prevent the possibility of  
leakage in the equipment compartment.  
1. Typical Location of Pump Unions  
1. Typical Location of Pump Union  
Figure 11. Typical Location of Pum p Unions  
Figure 10. Typical Location of Pum p Union  
7. Also, open the bleeder valve(s) located next  
to the sidewall of the skimmer area, Figure  
12, to allow air to escape from the pump(s).  
1. Bleeder Valves  
Figure 12. Bleeder Valves  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2002 Dimension One Spas Export Owners Manual  
8. Remove the filter and fill your hot tub with a hose through the empty filter compartment to a level of one  
to two inches above the bottom of the tile line.  
9. Remove the two shipping bolts located on the front of the pump mount and ensure that the gate valves  
on the pump(s) are in the open position (handles fully extended).  
10. Turn on the circuit breaker (not supplied by Dimension One Spas). Flashing dashed lines will appear for  
30 seconds on the Digital Display followed by the current water temperature (flashing).  
11. Push the JETS 1 and 2 pads to turn both pumps onto high speed. Let the system run for 30 to 45 seconds  
to prime the pumps. If there is no jet action, then the water level is too low or there is air trapped in the  
plumbing lines. To eliminate the trapped air, turn the pumps on and off several times to force the trapped  
air through the pumps. If there is still no jet action, and the bleeder valves have been open for some time,  
turn off the pumps and loosen the top pump unions slightly to let any trapped air escape. Re-tighten the  
pump unions and turn the pumps on again. Turn the pumps on and off several times until jets function  
properly.  
Ozone bubbles will continue to release from the skimmer recess Ultra Pure bleeder valve as long as  
the valve remains open. Once the pumps are primed, be sure that the bleeder is closed tightly.  
Note  
12. When the jets are in full operation, close the bleeder valves and push the UP pad until the desired hot tub  
temperature is indicated on the display screen. The screen will then read100° F (38° C) for thirty seconds  
to allow the thermostat time to read the correct current water temperature. Then, the screen will  
display the current hot tub water temperature.  
13. Once you have verified that the heater is functioning, you can reinstall the equipment compartment panel  
removed in Step 1.  
While setting the temperature, the Digital Display will read out the temperature up to 104° F (40°  
C). W ater tem peratures in excess of 104° F (40° C) should be used with extrem e  
caution.  
W arning  
Depending upon the size of the hot tub and the size of the circuit breaker used, heating will occur  
at the rate of 3° F (1.65° C) to10° F (5.5° C) per hour.  
Note  
14. After completing the above steps, it is necessary to ensure proper water chemistry. See the Water Care  
Guide accompanying this manual for instructions on maintaining clean and safe water. The schedule shown  
may require more frequent adjustment depending on the bather load.  
15. Place the thermal cover on the hot tub to conserve energy and to keep it ready for use.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2002 Dimension One Spas Export Owners Manual  
Ro u t in e Eq u ip m e n t Ma in t e n a n ce  
Dr a in in g Yo u r Eq u ip m e n t  
Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by  
children. To avoid accidents, ensure that children cannot use this system unless they are supervised at  
all times.  
Danger  
All models are gravity drained. Do not drain water onto your lawn or plants unless all of the bromine or chlorine  
has dissipated from the water. The sanitizer in your water will dissipate quickly by leaving the cover off and  
exposing the water to direct sunlight. Drain and replace your water every six months. For heavy water use, you  
may wish to change the water more frequently.  
You may purchase an optional submersible pump from your dealer or from our Virtual Showroom at  
www.d1spas.com to provide quicker drainage.  
Feature  
Filt e r Cle a n in g  
Before cleaning the filter element(s) place the spa in the “Standby” mode by pressing the Dimension One Spas  
ICON logo for 5 seconds. Your system is equipped with one or two top access filter cartridges. We recommend  
that you clean the filters every month as preventative maintenance.  
To clean the skimmer filter cartridge, remove the access lid covering the filter area. Lift the center float of the  
skimmer assembly until it is fully extended. Hold the centerpiece of the assembly and turn it counterclockwise until  
the flats of the basket are aligned with the securing tabs. Then pulls the basket assembly straight up to remove.  
Next, remove the E-Z Lock Filter cartridge by twisting the cartridge 1/4 turn counterclockwise to its stop. (Be  
careful not to overturn the filter) Then lift the filter out of its canister. Clean the cartridge with a high-pressure  
garden hose. Every other cleaning, soak the cartridges in a filter-cleaning solution, rinse it thoroughly, and reinstall.  
Replace the skimmer basket assembly and the access lid or cover. Exit the “Standby” mode by pressing Dimension  
Spas ICON logo for 5 seconds. After cleaning, run the pump for a few minutes at high speed, then return to the  
heating mode.  
To clean the Ultra Pure™ filter cartridge for those hot tubs with Ultra Pure, remove the access lid and remove  
the E-Z Lock Filter cartridge by twisting the cartridge ¼ turn counterclockwise to its stop. Then lift the filter out  
of its canister. Clean the cartridge with a high-pressure garden hose. Every other cleaning, soak the cartridge in  
Dimension One Spas’ Cartridge Cleaner, then rinse it thoroughly, and reinstall. Replace the access lid or cover.  
Exit the “Standby” mode by pressing Dimension Spas ICON logo for 5 seconds.  
Ligh t Bu lb Re p la ce m e n t  
All systems are equipped with a 12 volt light using a GE912 bulb. To change the bulb:  
1. Turn the power off and drain the system below the level of the light.  
2. Using the special tool provided in the owners manual packet,  
unscrew the cover for the light housing.  
3. Remove the old bulb and install the new bulb.  
4. Use the special tool to replace the cover for the light housing.  
5. Check to ensure proper operation of the new bulb before refilling  
the system.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Do not attempt to remove the light housing cover without lowering the water level below the light  
housing cover.  
W arning  
Do not attempt to remove the light housing cover without the special tool. If you are not able to  
locate it, contact the Dimension One Spas’ Service Department to have one sent.  
Note  
Be sure the O-ring is not damaged and is properly in place when replacing the lens. Contact  
Dimension One Spas if a replacement O-ring is needed.  
Note  
A Dynam ic L.E.D. Light is available as an optional accessory for many models. This light is  
preprogrammed with 13 different light shows. This light is also replaced in the same manner as  
described in the previous paragraph. Contact your dealer or visit our Virtual Showroom at  
http://d1spas.com to see if it is available for your model.  
Feature  
Su r fa ce Ca r e – Ult r a life a n d Gr a n it e x  
Your equipment has a very high quality finish. Stains and dirt will generally not adhere to the surface. We  
recommend cleaning the entire shell surface with Dimension One Spas’ W ater Line Cleaner. You may also use  
Dimension One Spas’ ph/Alkalinity Increaser or mild cleaners like Soft Scrub. Be sure to thoroughly rinse the  
shell. After cleaning, you will want to restore your hot tub shells original luster by using Dimension One Spas’  
Poli-Gloss.  
Do not use “409” type cleaners or other caustic solutions as they may damage the hot tub shell  
surface and void the warranty. If you are using baking soda to clean your hot tub shell, be careful  
not to get it on the skirt. It may bleach the wood.  
Caution  
Do not use citrus-based cleaners on the shell surface.  
Caution  
Granitex/Q uarite Plus  
If your spa is equipped with this material you must keep the spa covered when it is empty. When the spa is empty  
and the cover is not in place, and the spa is exposed to direct sunlight, it is vulnerable to ultraviolet light or solar  
damage. Temperatures generated by sunlight can become concentrated in the shell surface causing the shell  
material to delaminate from the urethane backing.  
Dim ension O ne “ EnviroTect” Skirts and Vinyl Covers  
The Dimension One EnviroTect skirts are unaffected by most corrosive substances, and will not absorb  
moisture. To maintain the original finish, clean with soap and water. No sealing or painting is required. To  
maintain a “nearly original” appearance we recommend applying 303 Protectant at least once a month on the  
Dimension One EnviroTect skirts and on the vinyl covers if they are exposed to direct sunlight. 303  
Protectant is rated at 40 SPF (Sun Protection Factor).  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Care for the W ood Spa Cabinet  
When properly cared for, the wood cabinet of your hot tub will maintain its beauty for many years. All woods  
react differently to the elements by expanding and contracting. To protect your beautiful wood finish, re-stain it  
every 3-6 months with Dimension One Spas’ Redwood or Coastal Gray Stain, which serves as a good sealing  
agent for the wood. Please note that the cabinet is not warranted against reaction to natural weather conditions.  
The wood must be properly maintained. Should your hot tub cabinet require re-conditioning, try Dimension One  
Spas’ W ood Refurbishing Kit.  
Sp e cia l Co ld We a t h e r In st r u ct io n s  
Slipping into your steamy water on a snowy, winter night is a refreshing experience. Many times, people who could  
never imagine being outside in winter weather, find themselves spending their winter nights doing just that, while  
relaxing in their hot tub with family and friends. Therefore, the best winterizing tips of all are to enjoy use of your  
system year-round.  
All systems manufactured by Dimension One Spas are designed for rigorous winter use. They are insulated to keep  
operating costs down and to protect plumbing and equipment whenever the products are operational. Each  
product line incorporates freeze protection mode to maintain water circulation during freezing conditions  
whenever the system has proper electrical power and water level. Therefore, a fully operational system is your  
number one defense against freeze damage.  
If you find it completely necessary to drain your water during the winter months, in an area where freezing  
conditions may exist, please adhere to all of the instructions in this section to minimize the risk of freeze damage.  
Failure to complete any of the steps satisfactorily will increase the chance of freeze damage, as small amounts of  
water trapped in pipes will expand as it freezes, and may result in damaged plumbing lines or fittings.  
Dimension One Spas does not recommend that you drain your system for the winter. Freeze damage  
caused by winterizing your system is specifically not covered by Your Warranty.  
Caution  
Item s Required for W interizing  
Phillips head screwdriver  
16” (40.6 cm) Channel-lock pliers  
High pressure air blower  
Commercial grade wet-vacuum  
3 gallons (11.37 liters) to 6 gallons (22.74 liters)  
of Non-Toxic Antifreeze  
Strong, able-bodied people capable of lifting system  
Into upright position  
Enough time (and patience) to perform all steps.  
Procedure for W interizing  
1. Shut the power off to the system and make sure that it cannot be accidentally turned back on.  
2. Remove filter elements from filter assembly.  
3. Drain water from the system using the drain fitting and garden hose or you may use a submersible pump  
for faster draining.  
4. Open the equipment compartment and locate pumps and heater.  
5. Remove all of the drain plugs from each pump.  
6. Loosen unions on both sides of each pump, and the heater if applicable.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
7. If your system has a Dynamic Jet Sequencer, please remove that access panel as well and loosen all unions  
on each of the sequencer valves. There are 6 sequencer valves, that means that you will have to loosen  
12 unions.  
8. Tip the system onto one side. (The system will have some water remaining, which will add to the  
weight). Be sure to have enough people available to safely lift the weight of your system. Do not tip  
system onto equipment bay side.  
9. Close all jets, by turning jet faces counter clockwise.  
10. Put on your protective goggles in order to protect eyes from air, water, antifreeze or debris exiting the  
jets or drains.  
11. Insert the hose of a high-pressure air blower into the filter element fitting. Some models may have 2  
filters. Begin with the left-hand filter fitting, which will help evacuate water from the circulation pump  
system. Then proceed to the right-hand filter fitting. When using air blower on single-filter systems or  
the right-hand fitting on dual filter systems, rotate each of the jet faces clockwise to open and counter-  
clockwise to close again. Do this to each jet face, one jet at a time. Be careful, as water will be coming  
out of each jet fitting as you perform this maneuver. Perform this operation, until no more water is  
coming from the jets.  
12. Remove jet faces and insert the hose of a high-pressure air blower into each jet fitting. Continue this  
process, until no more water comes out of any jet fitting or drain fitting and you no longer hear water  
gurgling within the plumbing. Place all jet faces in a plastic bag and set aside until you are ready to use  
your system again.  
13. Remove both bleeder valves from the top of the filter canister area. Place hose of a high-pressure air  
blower into the rear-most bleeder fitting first. Confirm that water mist is blowing from one or both of  
the circulation system return jets in the footwell of the system. You may also get some water mist  
blowing from the filter canister. Repeat this process with the front-most bleeder fitting. Confirm that  
water mist is blowing from the drain fittings of the jet pumps.  
14. Place the hose of a commercial grade, wet-vacuum over each jet fitting, bleeder valve fitting, and drain  
fitting to draw out as much remaining standing water as possible.  
15. Remove drain hose bib assembly from the outside bottom of the system.  
16. Use the wet-vacuum to remove standing water from the pumps and any other fittings within the  
equipment compartment.  
17. Once you are sure that all water is evacuated from the plumbing and equipment of the system, put the  
system back down in its normal position and repeat Step 10 and Step 11  
18. Read all Directions and Safety Precautions on the Swimming Pool or Recreational Vehicle antifreeze  
bottle before opening and using. Ensure that it is non-toxic and safe for this use. Beware of and follow all  
safety precautions.  
19. Using a long funnel, begin pouring non-toxic swimming pool or recreational vehicle water system  
antifreeze into the filter canister fittings, bleeder valve fittings and jet fittings of your system. Continue  
adding antifreeze until it comes out of the drain fittings or from the opening you are pouring it into. You  
must complete this task for every jet fitting in the system. Some of the antifreeze will seep into the  
system from the drain or jet fittings, which is okay, the goal is to have anti-freeze collect in the areas of  
the plumbing that would normally trap water. Use the funnel to also place antifreeze into the pump  
housing(s).  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2002 Dimension One Spas Export Owners Manual  
When pouring antifreeze into the rear-most bleeder valve fitting, you may see antifreeze pouring  
from one or both of the circulation system return fittings.  
Note  
DO NOT USE AUTOMOTIVE COOLING SYSTEM ANTIFREEZE IN YOUR SYSTEM. IT IS  
TOXIC AND HARMFUL TO HUMANS AND ANIMALS. CHECK WITH YOUR LOCAL SPA  
DEALER OR RV DEALER TO PURCHASE NON_TOXIC ANTIFREEZE THAT IS COMPATIBLE  
WITH DRINKING WATER SYSTEMS!  
Danger  
20. Replace all equipment access panels onto the system.  
21. Replace thermal cover and secure locking tabs. If your system is located in an area of high snowfall, you  
may want to take one more extra precaution to safeguard the life of your system cover. Span the cover  
with (2 or more) 2x4s cut to length to reach the outside edges of your cover. Place a sheet of plywood,  
cut to fit each half of the cover, over the 2x4s; this will carry the load of a heavy snow load and prevent  
the cover from warping or breaking. You can even tarp the system at this point for maximum protection.  
Spring Tim e Startup  
In the spring, or when your ready to start the system back up, follow these instructions.  
Make sure o-rings for pumps are in place and undamaged.  
Make sure all the fittings that you had to loosen are tightened.  
Replace all jet fittings, pump drain plugs, hose bib drains and bleeder valves  
Fill the system up, as you would normally do.  
Turn the power back on.  
Run the jets on high speed for about 15 minutes.  
Drain the water.  
Put your filter(s) back in.  
Refill and treat chemically like you would during a normal water change.  
Your system is equipped with automatic freeze protection. However, power outages can cause  
your system equipment to freeze quickly. During freezing conditions, check your system frequently  
to ensure proper operation. Always check your system after any power failure to ensure that it is  
operational. Draining and not operating your system disables this feature.  
Caution  
For additional information about winterizing your spa, please contact your local Authorized Dimension One Spas  
dealer.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Wa r r a n t y Se r v ice In fo r m a t io n  
Your hot tub warranty gives you specific coverage. Be sure to read the enclosed warranty sheet carefully.  
The warranty does not cover problems arising from misuse, abuse, or neglect, and it does not cover problems  
caused by improper installation or “perceived” problems caused by failure to read the hot tub owners manual. A  
service charge will be made if a service call is made for any of the following:  
1. Equipment failure due to improper/inadequate electrical service. All systems require dedicated circuits as  
described in this manual. Low voltage can cause equipment failure and seriously shorten equipment life. It  
is the owners responsibility to ensure proper electrical service is available.  
2. Failure of hot tub to reach desired temperature because the set temperature is not turned up high  
enough. Maximum thermostat setting is approximately 104° F (40° C).  
3. Burned out hot tub light. Bulbs are not covered.  
4. Hot tub water chemistry is the responsibility of the hot tub owner. Cloudy, dirty or chemically  
unbalanced water and cleaning of the hot tub filter are also the responsibility of the hot tub owner.  
5. Hot tub shell or equipment damage caused by improper water maintenance. Serious damage can be  
caused if your hot tub water is not maintained carefully and correctly.  
6. Poor jet action because the jet Selector valve is in the middle position. For full performance, turn the jet  
Selector valve to either the full clockwise or full counterclockwise position.  
Do not block air intakes located on the front left corner underneath the hot tub (the front right  
corner for the Chairman II and Triad II) and under the equipment access panel. Resulting  
malfunctions are not covered under warranty.  
W arning  
Granitex/Q uarite PlusDisclaim er  
This spa is insulated with high-density urethane foam for structural support and energy efficiency.  
When empty of water and left in the direct sunlight without the spa cover in place, the spa is  
vulnerable to ultra violet light or solar damage. Temperatures generated by sunlight can become  
concentrated in the shell surface causing the shell material to delaminate from the urethane foam  
packing. This occurrence is not covered under warranty. The spa cover must be kept on the spa  
while empty of water.  
Caution  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Glo ssa r y o f Te r m s  
Te r m  
Bleeder Valve  
Circulation  
Pum p  
De fin it io n  
A small valve used to relieve or expel air from the spas plumbing or pump.  
A pump that circulates the water in the spa continuously.  
Turning the heater element on when there is no water in the heater.  
Provides access to your spas equipment for a qualified service technician.  
Dry Firing  
Equipm ent  
Access Panel  
Filter Cartridge  
Your spas filters have been designed so that you may repeatedly clean and  
maintain the filter element as needed. The element is constructed of woven  
polyester rather than paper to ensure long life and proper filtration.  
A type of Circuit Breaker that automatically disconnects power to the spa when  
there is an electrical power leakage to ground.  
GFCI-Ground  
Fault Circuit  
Interrupter  
Gravity Drain  
Valve  
Used to drain your spa  
Free chlorine, bromine or iodine ions that are very strong oxidizers used to  
sanitize water.  
Halogens  
This is a pad accessed by pressing the Dimension One Spas Logo on the far right  
of the Top Side Control Panel.  
Return the water into the spa from the equipment. The jets produce a turbulent  
flow of water mixed with air to provide a concentrated body massage  
Illuminates the spa  
ICO N Pad  
Jets  
Light  
When the circuit breaker size is smaller than the total power needed to operate  
both the heater and the jet pump at the same time, load sharing automatically  
turns off the heater when a jet pump is turned onto high speed.  
The electronic control system that governs all of the electrically operated  
components of your spa utilizes an advanced microprocessor and solid-state  
electronic devices to activate all user and maintenance options. A backlit, highly  
reliable liquid crystal display gives you a complete update of the spa status at any  
time of the day or night. Temperature setting, as well as control of the light, jets,  
filtration, and time of day display, are all instantly available from, and controllable  
at, the topside control panel.  
Load Sharing  
Lower Control  
System  
A specialized ultraviolet light that changes oxygen into ozone for use in the water  
sanitation process.  
O zone  
Generator  
Safety device(s) that sends a signal to the electronic control system that there is  
adequate water flow to turn the heater on.  
Produces water flow through the heater, filter, sanitation system and the main  
jets in the spa. The pump will operate automatically during filtration and heat  
cycles. This pump can also be operated manually by depressing the “jets” pad on  
the topside control panel which will allow you to choose between two speeds  
Flow Switch  
Pum p  
Low speed for efficient water circulation during heating and filtration  
modes, and for gentle jet resistance or massage action.  
High speed for maximum jet action.  
Located on the top edge of the spa, it diverts jet power from one area of the spa  
to another.  
Please use the serial number (located on the left corner pedestal) in  
communication with your dealer.  
Selector Valve  
Serial Num ber  
Valves located within the spas internal plumbing, which are used by service  
personnel to shut off water flow to the heater and pumps. All valves must be  
Slice Valves /  
Shutoff Valves  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Te r m  
De fin it io n  
completely open during normal operations.  
(Available on Dimension One Spas only) Smart Heat optimizes heat recovery  
using the amperage that you have available. Along with computerized load sharing,  
that automatically recognizes the number of jet pumps in use, compares it with  
the available power, Smart Heat recognizes the difference between the set  
temperature and the actual water temperature, and adjusts the heater to  
optimize the heater output.  
Sm art Heat  
Measures the temperature of the water inside the spa. This temperature sensor  
is used to control the spa heater and the temperature is displayed on the spa side  
control panel.  
Tem perature  
Sensor  
Used to control temperature, pumps for jets, spa light, system clock, automatic  
filtration cycles, and other advanced functions.  
Connects the spa plumbing to the equipment. The unions allow a service  
technician to remove equipment without cutting plumbing.  
A device used to inject air into the water.  
Top Side  
Control Panel  
Unions  
Venturi  
A safe, water sanitizer that can be used in place of chlorine.  
Vision Cartridge  
In addition to the skimmer, the water return fittings provide water inlets to your  
spa pumps. DANGER – Never Block Or Remove Any Of The Water Return  
W ater Return  
Fittings  
Fittings.  
A floating water referencing device that skims debris from the surface of the  
water.  
W eir Skim m er  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2002 Dimension One Spas Export Owners Manual  
Tr o u b le sh o o t in g Gu id e  
H e a t in g Syst e m  
Sym ptom  
Problem  
Corrective Action  
1.  
Temperature setting is  
too low  
1.  
Turn up the thermostat  
Does not heat  
2.  
3.  
Dirty filter  
2.  
3.  
Clean filter  
Flow switch malfunction  
Call for service  
1.  
Temperature setting is to  
high  
1.  
Turn down the thermostat  
Too hot  
2.  
High limit tripped  
2.  
Call for service  
Possible temperature sensor  
failure  
Call for service  
Flashing  
tem perature of  
34°F (-16.6° C)or  
134°F (56.6° C)  
appears on the  
display  
Water level  
Fill hot tub to 1” (2.54 cm) to 2” (5.08 cm) above bottom of the tile line  
Hot Tub  
Tem perature  
erratic  
Ele ct r ica l Syst e m  
Sym ptom  
Problem  
Corrective Action  
No power  
Check circuit breaker and/or GFCI  
W ill not turn on  
– in any m ode  
Normal automatic daily  
power filtration, or anti-  
freeze cycle  
No action required  
Turns on by itself  
Light is out  
Burned out bulb  
Replace bulb  
1.  
Automatic timer  
has shut pump off  
1.  
2.  
Push JETS pad again to start another cycle  
Pum p shuts  
down  
unexpectedly  
while in use  
2.  
Motor over-heated  
and automatic  
protective device  
has shut down  
pump(s)  
If pump(s) will not restart when JETS pad is pushed, call for service  
Make sure that the equipment panel vent area is not blocked. Vent blockage can  
cause serious damage to your equipment.  
Possible sensor errors  
1.  
2.  
Check water level  
Clean filter  
3 flashing LEDs  
appear on the  
Top Side Control  
If problem persists:  
1. Turn off power  
2. Restart the system  
If problem persists:  
Call for service  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
Wa t e r Syst e m  
Sym ptom  
Problem  
Corrective Action  
Pulsating jets  
Water level too low  
Fill with water to 1” (2.54 cm) to 2” (5.08 cm) above bottom of the tile line  
1.  
2.  
Jets are turned off  
1.  
2.  
Turn jets on by turning jet face clockwise  
No Jet Action,  
or action is  
poor  
Diverter Valve  
turned  
Turn the Diverter Valve clockwise or counter clockwise  
3.  
4.  
5.  
Dirty Filter  
3.  
4.  
5.  
Clean Filter  
Air lock  
Loosen pump union to allow air to bleed  
Open gate valve  
Gate valve closed  
1.  
Possible sensor  
errors  
1.  
2.  
3.  
Check water level  
Clean filter  
If problem continues:  
The “Check  
W ater  
Level…..”  
a.  
Turn off  
power  
scrolling  
m essage and /or  
3 flashing  
L.E.D.s appear  
on the display.  
b.  
Restart the  
spa  
4.  
If problem persists:  
a. Call your dealer for service  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2002 Dimension One Spas Export Owners Manual  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2002 Dimension One Spas Export Owners Manual  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2002 Dimension One Spas Export Owners Manual  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cobra Electronics Portable Radio 200GTL DX User Manual
Conair Styling Iron CS64 User Manual
Continental Electric Fryer CP43269 User Manual
Craftsman Saw 3BS12401 User Manual
Danby Freezer SCF401W User Manual
Delkin Devices Indoor Fireplace EI 25 1 User Manual
Dynaudio Speaker BX30 User Manual
EdgeStar Dehumidifier DEP400EW User Manual
Generac Power Systems Portable Generator 9592 3 User Manual
Global Machinery Company Saw TTS5000M User Manual