Dell PowerEdge C410x
Hardware Owner’s Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
NOTES, CAUTIONS, AND WARNINGS
CONTENTS
I
II
INTRODUCTION
1
Checklist
1
CHAPTER 1: PRODUCT OVERVIEW
2
1.1
A Tour of the System
2
2
3
1.1.1. System Front View
1.1.2. System Back View
1.2
System LEDs Description
1.2.1. Front System LEDs
1.2.2. LAN LEDs
4
4
5
CHAPTER 2: REMOVING AND INSTALLING HARDWARE
Safety Measures
6
6
2.1. Dell PowerEdge C410X Middle Board Connectors and Jumpers
2.2. System Cover
7
8
2.3. GPGPU Cage
9
2.4. Replacing GPGPU Card
10
14
16
18
19
22
25
26
28
2.5. System Fans
2.6. System Fans Cages
2.7. Power Supplies
2.8. Removing Power Distribution Board (PDB)
2.9. Replacing iPass Board
2.10. Replacing Middle Board
2.11. Replacing Front I/O Panel
2.12. Installing the Rail and the System
CHAPTER 3: CABLE ROUTINGS
30
II
Download from Www.Somanuals.com. All Manuals Search And Download.
iPass Port Mapping
31
CHAPTER 4: BMC REMOTE MANAGEMENT CONSOLE
32
Initial Configuration via DHCP Server
32
Static/DHCP IP Controlled by Front Panel Button
33
Remote Management Console Overview
34
Enter Dell Remote Management Console
35
Properties
35
Configuration
Network
Security
User
Services
IPMI
36
36
37
38
39
40
Sessions
Updates
Utilities
42
43
44
Server Information
Power Control
Power Consumption
GPU Power Consumption
45
45
46
47
Thermal
Fans
Temperatures
48
48
48
System Event Log
Platform Events
Traps Settings
49
50
51
52
Email Settings
CHAPTER 5: TROUBLESHOOTING YOUR SYSTEM
53
CHAPTER 6: GETTING HELP
58
Contacting Dell
58
INDEX
59
III
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Checklist
Carefully unpack the Dell PowerEdge C410X server and check that the following items were included.
One Dell PowerEdge C410X system
Dell PowerEdge C410x Getting Started Guide
Safety, Environmental, and Regulatory Information (SERI)
Warranty and Support Information (WSI) or End User License Agreement (EULA)
Contact Dell if some items are missing or appear damaged.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Product Overview
1.1 A Tour of the System
The following sections describe the external features of the Dell PowerEdge C410X server.
1.1.1. System Front View
Figure 1 – Front View
1
2
3
4
5
6
7
System LED
UID LED/Button
Power LED/Button
GPGPU Cage 1
GPGPU Cage 2
GPGPU Cage 3
GPGPU Cage 4
8
GPGPU Cage 5
GPGPU Cage 6
GPGPU Cage 7
GPGPU Cage 8
GPGPU Cage 9
GPGPU Cage 10
9
10
11
12
13
2
Download from Www.Somanuals.com. All Manuals Search And Download.
1.1.2. System Back View
Back view of system is shown below:
Figure 2 – Back View
1
2
Power Module 1
11
12
13
14
15
16
17
18
19
iPass connector 6
Power Module 2
Power Module 3
Power Module 4
BMC LAN Cable
iPass connector 1
iPass connector 2
iPass connector 3
iPass connector 4
iPass connector 5
iPass connector 7
iPass connector 8
GPGPU Cage 11
GPGPU Cage 12
GPGPU Cage 13
GPGPU Cage 14
GPGPU Cage 15
GPGPU Cage 16
3
4
5
6
7
8
9
10
3
Download from Www.Somanuals.com. All Manuals Search And Download.
1.2 System LEDs Description
1.2.1. Front System LEDs
The front system LEDs contain Status LED, Power LED and UID LED information.
The detailed LEDs information is listed below:
Figure 3 – Front System LEDs
Table 1 Front System LEDs
Status LED
Displays status/errors and is controlled by BMC.
Color
Condition
Blink Fast
On
Occurrence
Amber
Power supply fail
FAN fail or sensor error
GPU card fail
Blink
UID LED
Lights when front or rear ID button is pressed.
Color
Condition
Off
Occurrence
Blue
No identification
Blinking
ID Button pressed on system (ID command
executed)
Lights green when server is powered on.
Color
Condition
Occurrence
Power LED
On
Power on
Green
Power on fail or without
any GPU card
Blinking
4
Download from Www.Somanuals.com. All Manuals Search And Download.
1.2.2. LAN LEDs
Figure 4 – LAN LEDs
Table 2 LAN LEDs
LAN
LAN Link/Activity
Color
Condition
On
Occurrence
Green
LAN Link / no Access
LAN Access
Blink
Off
N/A
Idle
10 LAN Speed
100 LAN Speed
N/A
Off
10Mbps connection
Green
On
10Mbps connection
Blink
On
Port identification with 10 or 100Mbps connection
1Gbps connection
GbE LAN Speed
Yellow
Blink
Port identification with 1Gbps connection
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Removing and Installing Hardware
Safety Measures
Computer components and electronic circuit boards can be damaged by discharges of static electricity.
Working on computers that are still connected to a power supply can be extremely dangerous. Follow the
simple guidelines below to avoid damage to your computer or injury to yourself.
Always disconnect the computer from the power outlet whenever you are working inside the
computer case.
If possible, wear a grounded wrist strap when you are working inside the computer case.
Alternatively, discharge any static electricity by touching the bare metal system of the
computer case, or the bare metal body of any other grounded appliance.
Hold electronic circuit boards by the edges only. Do not touch the components on the board
unless it is necessary to do so. Do not flex or stress the circuit board.
Leave all components inside the static-proof packaging until you are ready to use the
component for the installation.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1. Dell PowerEdge C410X Middle Board Connectors and Jumpers
Figure 5 displays the most important DELL PowerEdge C410X middle board components.
Figure 5 – Middle Board Connectors and Jumpers
Items
6.
Component
Item
1.
Component
PCI-E connectors
PCI-E connectors
Power connectors
iPass connectors
Battery
Front I/O connector
FAN connectors
2.
7.
3.
8.
FAN LED connectors
Failover setting pin header
4.
9.
5.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2. System Cover
WARNING:
Before you remove or install the system cover:
make sure the server is not turned on or connected to the AC
power.
Follow these instructions to remove the system cover:
1. Loosen and remove the securing screw on the top of the system.
2. Slide the cover horizontally to the back using the traction pad and remove the cover in the
direction of the arrow.
NOTE:
This system must be operated with the system cover installed to ensure proper cooling.
Follow these instructions to install the system cover:
Reverse the steps above to install the system cover.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3. GPGPU Cage
NOTE:
When you remove or install the GPGPU cage, note the following points:
Take note of the drive tray orientation before sliding it out.
The tray will not fit back into the bay if inserted incorrectly.
Follow these instructions to remove the cage:
1. Press the release button along the direction of the arrow.
2. Slide the cage assembly out of the system.
Follow these instructions to install the cage:
Reverse the steps above to install the cage.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4. Replacing GPGPU Card
WARNING:
Before you remove or install the system fan, take the steps below:
Make sure the system is not turned on or connected to the AC power.
Disconnect all necessary cable connections.
Turn off the specific single GPU cage power.
Failure to observe these warnings could result in personal injury or damage to
the equipment.
Follow these instructions to replace a GPGPU card:
For M1060 System
1. Insert the GPGPU card by 45 degree and push it into socket vertically.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Secure the card in place with screws and place the GPGPU side cover as illustration arrow show.
3. Secure the GPGPU side cover and back cover in place with screws.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Follow these instructions to replace a GPGPU card:
For M2050 System
1. Attach the support bracket on the GPGPU board and secure it in place with screws.
2. Insert the GPGPU card by 45 degree and push it into socket vertically.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Secure the card in place with screws and place the GPGPU side cover as illustration arrow show.
4. Secure the card in place with screws and place the GPGPU side cover as illustration arrow show.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
2.5. System Fans
In case a of system fan failure, you can quickly replace the system fan.
WARNING:
Before you remove or install the system fan, take the steps below:
Make sure the system is not turned on or connected to the AC power.
Disconnect all necessary cable connections.
Failure to observe these warnings could result in personal injury or damage to
the equipment.
Follow the instruction to remove the system fan:
1. Loosen and remove the securing screw on the top of the system.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Lift the system fan out of the system fan cage.
Follow these instructions to install the system fan:
Reverse the step above to install the system fan.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
2.6. System Fans Cages
WARNING:
Before you remove or install the system fan cage, take the steps below:
Make sure the system is not turned on or connected to the AC power.
Disconnect all necessary cable connections.
Failure to observe these warnings could result in personal injury or damage to
the equipment.
1. Loosen and remove the securing screw on the top of the system.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Lift the system fan out of the system fan cage. See System Fans on page 14 for detail instruction.
3. Loosen and remove the securing screw on the top of the system fan cage.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
2.7. Power Supplies
In case of a power supply failure, you can quickly replace the power supply unit.
Follow these instructions to remove the power supply:
WARNING:
In order to reduce the risk of injury from electric shock, disconnect the failed
power supply from the AC power before removing it from the system.
1. Pull up the power supply handle.
2. Press the retaining clip on the right side of the power supply along the direction of the arrow.
3. At the same time, pull out the power supply by using its handle.
NOTE: The power supply takes considerable force to remove.
Follow these instructions to install the power supply:
Insert the replacement power supply firmly into the bay. The retaining clip should snap. Connect the AC
power cord to the replacement power supply.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
2.8. Removing Power Distribution Board (PDB)
Follow these instructions to remove the PDB:
WARNING:
In order to reduce the risk of injury from electric shock, disconnect the failed
power supply from the AC power before removing it from the system.
1. Loosen and remove the securing screws on the top of the system.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Loosen and remove the securing screws on the top of power supply cage and remove the
securing screw on the side of the system.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Loosen and remove the securing screws on the PDB.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
2.9. Replacing iPass Board
Follow these instructions to replace the iPass board:
1. Loosen and remove the securing screws on the top of the system.
2. Remove the power supply. See Power Supplies on page 18 for detail instruction.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Loosen and remove the securing screws on the top of power supply cage and remove the
power supply cage out of the system.
4. Loosen and remove the securing screws on the top of iPass connector cage.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Remove iPass connector cage.
6. Loosen and remove the securing screws on the top of iPass board.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
2.10. Replacing Middle Board
Follow these instructions to replace the middle board:
1. Remove the system cover. See System Cover on page 8.
2. Remove the fourteen (14) screws securing the mainboard in place. Lift the middle board out of
the system in the direction of the arrow, front edge first, to clear the I/O ports.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
2.11. Replacing Front I/O Panel
WARNING:
Before you remove or install the system cover:
make sure the system is not turned on or connected to the AC
power.
1. Loosen and remove the securing screws as illustration shown below
2. Loosen the securing screws and remove the ear board cover.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Loosen and remove the securing screws on the ear board.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
2.12. Installing the Rail and the System
WARNING:
Before you remove or install the system cover:
make sure the system is not turned on or connected to the AC
power.
Follow these instructions to install the rail into a rack:
1. Install the sliding rails into the rack.
2. Align the inner rails with the sliding rails of the rack.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Push the system into the sliding rails until the locking latch clicks into place.
4. Connect ipass connectors and power connectors.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Cable Routings
1
2
3
4
5
6
Fan Power Cable
Front I/O Cable
RJ45 Cable
Fan LED Cable
GPU Cable
Switch Cable
30
Download from Www.Somanuals.com. All Manuals Search And Download.
iPass Port Mapping
IPASS
GPGPU
1, 15
IPASS
GPGPU
1,2 , 15, 16
N/A
1
1
5
Mapping 1
5
VS
VS
VS
VS
VS
VS
VS
VS
2, 16
2
3, 13
4, 14
2
6
3,4, 13, 14
N/A
Mapping 2
6
3
5, 11
6, 12
3
7
5,6 , 11, 12
N/A
Mapping 3
7
4
7, 9
4
8
7,8 , 9, 10
N/A
Mapping 4
8
8, 10
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: BMC Remote Management Console
This chapter provides information on the various functions of the Dell Remote Management Console GUI’s
(Graphics User Interface).
Initial Configuration via DHCP Server
Before entering the Dell Remote Management Console, you need to connect the DHCP server in the
subnet to which it is physically connected. If a DHCP server is found, it may provide a valid IP address,
gateway address and net mask. Before you connect the device to your local subnet, be sure to complete
the corresponding configuration of your DHCP server. It is recommended to configure a fixed IP
assignment to the MAC address of the system.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Static/DHCP IP Controlled by Front Panel Button
The following illustration shows the instruction for gathering IP source using front panel button.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Management Console Overview
1.
Open a web browser and type in your identified IP. The IP address can be found using your DHCP
server.
2.
3.
A dialog box prompts you to enter Username and Password.
Enter the following values:
Username: root
Password: root
NOTE: The default user name and password are in lower-case characters.
NOTE: When you log in using the root user name and password, you have full administrative
privileges. It is advised that once you log in, you should change the root password.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Enter Dell Remote Management Console
After you successfully log into your Dell Remote Management Console, the Remote Management Console
GUI appears.
Properties
Properties displays the firmware version of current remote client system.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuration
Network
You can view and modify the network settings on this screen. Select whether to obtain an IP address
automatically or configure one manually. It is recommended to use DHCP if your environment has a DHCP
server. You can set DHCP (obtain the IP address automatically) or STATIC IP (configure the IP address
manually). When you finish configuration, click Apply Changes or for re-configuration click Refresh.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Security
Security shows the current certificate status. To generate a new certificate, click Generate Certificate .
To upload a certificate, click Upload Certificate.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
User
To configure a specific user, click the User ID. To display new user information, click Refresh.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Services
You can configure the web server parameters (such as, HTTP Port Number, HTTPS Port Number, and
Timeout) on a remote computer. By default, the timeout is 5 for the Max Sessions and 1 for the Active
Sessions.
When you finish the configuration, click Apply Changes.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
IPMI
This screen contains two sections: IPMI Serial and IPMI Settings.
IPMI Serial
There are three serial configuration in IPMI Serial: Connection Mode Settings, Baud Rate, and Channel
Privilege Level Limit.
The Connection Mode Settings allows user to select the Console redirection type and to manage the
system from a remote location.
Once the connection mode is set, select the Baud Rate from the drop-down list.
With Channel Privilege Level Limit, users can be configured to operate with a particular maximum Privilege
Level. Privilege levels tell the BMC which commands are allowed to be executed. Table 3 lists the currently
defined User Privilege Levels.
Table 3 User Privilege Levels
User
This may be considered the lowest privilege level.
Operator
All BMC commands are allowed, except for configuration commands that
can change the behavior of the out-of-band interfaces. For example,
Operator privilege does not allow the capability to disable individual
channels, or change user access privileges.
Administrator
All BMC commands are allowed, including configuration commands. An
Administrator can even execute configuration commands that would
disable the channel that the Administrator is communicating over.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
IPMI Settings
IPMI Settings provides remote configuration over LAN. To activate IPMI remote configuration by LAN,
check Enable IPMI Over LAN option, define the Channel Privilege Level Limit, and enter the Encryption
Key.
When you finish the configuration, click Apply Changes.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Sessions
This screen displays information on Active Sessions. Additionally, the trash can icon provides the delete
function for privileged users. Click Refresh to refresh the Sessions status.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Updates
The firmware can be updated remotely.
To update firmware, follow the instruction below:
1. Select the file on your local system using Browse.
2. Click Update to delete the current version and update to the new version.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Utilities
Utilities provides System reboot and Factory default restore functions.
To reboot system, click Reboot.
To restore factory default, click Factory Default.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Information
Power Control
The Power Control allows you to power on/off/cycle the remote host system. Additionally you can see the
remote power status.
To perform the power control operation, select the operation and click Apply Changes.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Consumption
This screen displays information on the system power consumption. The information includes Current
Power Consumption, Power Consumption Monitoring Start Date, Max/Min Power Consumption, and
Average Power Consumption.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
GPU Power Consumption
This screen displays the status of GPU power consumption.
Each sensor displays different color to indicate the health status of a specified GPU device.
The green color indicates the device is healthy and there’s no sensor that has any alert.
The yellow color indicates the device has at least one sensor that has warning alert.
The red color indicates the device has at least one sensor that has a critical alert.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Thermal
This screen displays the Fans and Temperatures sensors of a remote host system.
Click Refresh to update current health status for both Fans and Temperatures.
The green color indicates the device is healthy and there’s no sensor that has any alert.
The yellow color indicates the device has at least one sensor that has a warning alert.
The red color indicates the device has at least one sensor that has a critical alert.
Fans
Temperatures
48
Download from Www.Somanuals.com. All Manuals Search And Download.
System Event Log
System Event Log: It records the event when sensor has an abnormal state. When the log matches the
pre-defined alert, the system sends out the notification automatically, if it is pre-configured.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Platform Events
A platform event filter (PEF) can trigger an action and generate an alert when a critical hardware-related
event occurs. For each PEF, you can choose the action to be taken when a platform event occurs. You
can also choose to generate and send an alert when a platform event occurs.
In the Platform Events screen, you can enable the generation of platform event alerts globally by clicking
Global Alerting Enable.
When you finish the configuration, click Apply Changes.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Traps Settings
In the Trap Settings, user can set the IPv4 and Ipv6 Destination List.
IPv6 and IPv4 are two completely separate protocols. IPv6 is not backwards compatible with IPv4, and
IPv4 hosts and routers will not be able to deal directly with IPv6 traffic.
IPv6 has a significantly larger address space than IPv4. This results from the use of a 128-bit address,
whereas IPv4 uses only 32 bits.
When you finish the configuration, click Apply Changes.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Email Settings
If you want the alert to be sent by email, you can configure to specify the e-mail address, subject and
message in the Email Settings. After you finish the configuration, click Apply Change to save the settings.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Troubleshooting Your System
Safety First—For You and Your System
WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift
the system by yourself.
WARNING: Before removing the system cover, disconnect all power, then unplug the AC power cord, and then
disconnect all peripherals, and all LAN lines.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
Symptom: iPass card / port not recognized by the system
Check System Status (System must stay switched off)
1. Plug-in all four power cords to the 220V A/C power supply.
NOTE: Do not press power button on the system.
2. Check front panel LED (ID and Power LED)
ID and Power LED should not light at the beginning.
After 30 seconds or so, when BMC is ready, ID LED and Power LED blink once.
3. System powers on. After 40 seconds, power LED lights.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
4. When GPU cards are ready, power on the system for test.
5. All GPU cards LED should lights. If not, see Checking GPU Card on page 57.
Checking GPU Card
1. Power off and remove top cover.
2. Power on and check if GPU card LED lights.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
3. If not, power off, then reinstall GPU card again or swap GPU card.
4. If not, see Check iPass cable.
Checking iPass Cable
1. Check if iPass cable is properly connected.
2. If not, power off the system and plug-in power cable again.
3. If not, swap iPass cable.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Checking iPass Connector to PowerEdge C6100 Systems
1. Check BTB Connectors to iPass Board.
2. Check System SMBUs device routing table.
IPASS TOP
iPass 1: Slot 1/15
IPASS Bottom
iPass 5: Slot 2/16
iPass 6: Slot 4/14
iPass 7: Slot 6/12
iPass 8: Slot 8/10
iPass 2: Slot 3/13
iPass 3: Slot 5/11
iPass 4: Slot 7/9
Check if iPass Board (GS-IPASS2 / GS-IPASS3) is installed properly
1. Power off the system.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Remove top cover.
3. Remove PSU top cover.
Press
57
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Remove power cage.
5. Press iPass board to ensure it contacts middle plane.
6. Restart system and test it again.
Chapter 6: Getting Help
Contacting Dell
For customers in the United States, call 800-WWW-DELL (800-999-3355).
NOTE: If you do not have an active Internet connection, you can find contact information on your
purchase invoice, packing slip, bill, or Dell product catalog.
Dell provides several online and telephone-based support and service options. Availability varies by
country and product, and some services may not be available in your area. To contact Dell for sales,
technical support, or customer service issues:
1. Visit support.dell.com.
2. Click your country/region at the bottom of the page. For a full listing of country/region click All.
3. Click All Support from Support menu.
4. Select the appropriate service or support link based on your need.
5. Choose the method of contacting Dell that is convenient for you.
58
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
back view, 3
iPass port mapping, 32
LAN LEDs, 5
cable routings, 31
checking GPU card, 55
checking iPass cable, 56
checking iPass connector, 57
checklist, 1
middle board
replacing, 25
middle board connectors and jumpers, 7
platform events, 51
power consumption, 47
power distribution board
removing, 19
configuring
IPMI, 41
network, 37
security, 38
power supplies, 18
rail and system
services, 40
sessions, 43
installing, 28
user, 39
remote management console
overview, 35
email settings, 53
firmware
safety measures, 6
server information
power control, 46
system cover, 8
updates, 44
front I/O panel
replacing, 26
front view, 2
system event log, 50
system fans, 14
getting help
contacting Dell, 60
GPGPU cage, 9
GPU power consumption, 48
initial configuration via DHCP server, 33
iPass board
system fans cages, 16
system LEDs
front, 4
traps settings, 52
troubleshooting your system, 54
utilities, 45
replacing, 22
59
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Compaq Computer Hardware 164LX User Manual
Continental Home Speaker System MATE2 User Manual
Craftsman Lawn Mower 247887330 User Manual
Cres Cor Blender IFW61RR User Manual
Cuisinart Blender CBT500L User Manual
Curtis Mathes Blu ray Player CMMBX72 User Manual
Dynex Network Card DX FC103 User Manual
Electro Voice Portable Speaker E V ONE User Manual
Frigidaire Oven 318201532 User Manual
GE Monogram Refrigerator Built In All Refrigerator Freezer User Manual