DMP Electronics Network Router LT 0424 User Manual

PROGRAMMING INSTRUCTIONS  
Ether-ComTM  
Description  
The Ether-ComTM Single Port Router allows a DMP 1912XR, XR200 or XR200-485 Command ProcessorTM panel to  
communicate to a DMP SCS-1 Receiver using an existing Ethernet network. The router operates as an interface  
between the panel and the network.  
What’s needed  
Additional equipment needed to program the Ether-ComTM:  
386 or better laptop or PC  
WindowsTM 95 or 3.1 with a communication software package such as HyperterminalTM or TerminalTM  
DMP Model 396 programming cable  
10BaseT Ethernet cable  
Configuration for use with a DMP 462N or 862N  
The following configuration is designed for applications where the Ether-ComTM server is used as the interface  
between the DMP 462N or 862N Network Interface Card on a 1912XR/XR200/XR200-485 panel and an ethernet  
network.  
1912XR/862N orXR200/462N  
Configure the communication software package on your laptop or PC for 9600 baud, 8 bits, no parity 1 stop bit and  
no flow control. Connect the DMP Model 396 programming cable to the COM port on your laptop or PC that you  
configured in your communication software. Connect the other end of the Model 396 programming cable to the  
Ether-ComTM connector supplied with the unit.  
DO NOT CONNECT the Ether-ComTM to an Ethernet network at this point. Apply power to the unit. If the unit  
passes its power-up diagnostics the following message should be displayed:  
Ethernet Address: 00-80-a3-0f-4a-d4  
Flash Rom Version 2.0 (May 12, 1998)  
Internet Address: 10.17.39.1  
Flash Version:  
3.5/1 (970707)  
Current Diagnostics report:  
NVR Config:  
CPU Speed:  
Flash Version:  
Errors:  
Normal  
Ram Size:  
Gate Array:  
256 KB  
Rev 2  
10 MHz  
3.5/1 (970707)  
Network  
Ethernet: None  
No network was detected. Press a key within  
10 seconds to access bootmode commands>  
Press the Return key to access the Boot> prompt.  
Enter the following commands at the Boot> prompt:  
1.  
2.  
CHANGE BOOTP DISABLED  
CHANGE DHCP DISABLED  
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282  
LT-0424 (1/99)  
Downloaded from: http://www.guardianalarms.net  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. CHANGE FLOW CONTROL NONE  
6. CHANGE DEDICATED TCP xxx.xxx.xxx.xxx:2001U (where xxx... is the IP address of the Ether-ComTM  
connected to the SCS-1 Receiver or PC running Remote Access+TM).  
7. CHANGE AUTOSTART ENABLED  
8. SHOW SERVER - Check and confirm the unit’s IP address, Subnet Mask and the Gateway address.  
10. SHOW PORT - Check and confirm the speed, flow control, dedicated service, and autostart options are  
set correctly. (The unit is now ready to be connected to the 462N/862N with the cable provided with the  
ETHER-COM.)  
11. LOGOUT  
Important Note  
Once the ETHER-COM has been configured in this manner, no local access is allowed through the serial port  
while the unit is connected to the network. To reconfigure the Ether-Com you must remove power from the unit,  
disconnect it from the network, and then reapply power. Press the Enter key within 10 seconds to enter the  
configuration mode. Enter the command FLUSH NVR to return the unit to its factory defaults. This erases all  
options including the IP address.  
SCS-1 Receiver  
The unit that connects to the SCS-1 Receiver is configured in the same manner with the exception of Dedicated  
Service.  
The CHANGE DEDICATED option will not include any IP address, CHANGE DEDICATED TCP :2001U. This is  
necessary because the unit connected to the receiver will need to communicate with many different IP addresses.  
Configuration for use with Remote Access+™ on a PC  
This configuration is for applications where the Ether-Com server is used as the ethernet network interface for an  
IBM compatible PC on which is installed the DMP Remote Access™ software. The Remote Access program is  
used as a monitoring automation system and should be configured for HST Monitoring to allow it to process  
incoming alarm and system information from DMP panels installed on the same network.  
HST Monitoring  
The unit that connects to your PC running Remtoe Access+TM is configured in the same manner with the exception  
of Dedicated Service.  
The CHANGE DEDICATED option will not include any IP address, CHANGE DEDICATED TCP :2001U. This is  
necessary because the unit connected to the receiver will need to communicate with many different IP addresses.  
Ether-Com Programming  
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Monitoring Products  
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Conair Iron GS1 User Manual
Craftsman Lawn Mower 37624 User Manual
Dacor Grill Accessory AEGR User Manual
Dodge Automobile 2004 Caravan User Manual
Dynacord Kitchen Entertainment Center ENTERTAINMENT SYSTEM User Manual
Dyson Vacuum Cleaner DC18 User Manual
Edimax Technology Network Router AR 6024 User Manual
ELAN Home Systems Video Gaming Accessories ES370 User Manual
Escali Scale Granda Platform Scale User Manual
Extron electronic Stereo Amplifier CVEQ 100 MAAP User Manual